{"title":"Process Control – Dosing Pumps","description":"","products":[{"product_id":"pool-line-ph-controller-and-dosing-pump-bl100-meter-and-probe","title":"Pool Line pH Controller and Dosing Pump - BL100-Meter and probe - BL100-00","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eBL100 pH Controller and Dosing Pump is a system engineered for maintaining the pH of swimming pools,  hot tubs,  and spas. Typically chlorine,  whether liquid or solid,  is alkaline and will raise the pH of the water that it is added to. As the pH increases above pH 7.4,  a form of chlorine known as hypochlorite ion (OCl\u003csup\u003e-\u003c\/sup\u003e) increases. This form of chlorine is 100 time less effective at killing bacteria as compared to the other form of chlorine known as hypochlorous acid (HOCl). For this reason it is important to maintain the correct pH level in order to ensure that the more powerful hypochlorous acid form is available for disinfection. The BL100 was developed to be an inexpensive solution for the consumer to maintain the ideal pH at all times. Simply insert the probe and injection valve in-line with the recirculation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl100.gif\" alt=\"''\" width=\"1000\" height=\"1001\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe BL100 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth pH and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level alarms for pH. When an alarm is activated,  all dosing will stop. For added safety,  the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-flow.jpg\" alt=\"flow rate\" width=\"1000\" height=\"727\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate,  like the proportional band,  allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-proportional.jpg\" alt=\"Automatic Proportional Pump Control\" width=\"1000\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed,  will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-level.jpg\" alt=\" Acid Tank Level\/Flow Switch Input\" width=\"1000\" height=\"725\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/peristaltic-pump.jpg\" alt=\"Pooline Peristaltic Pump\" width=\"1000\" height=\"1000\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe BL100 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Persitaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL100-HI10053_flowcellprobe.jpg\" alt=\"pH probe mounted in flow thorugh cell\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003epH electrode with flow cell\u003c\/h5\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe BL100 is available in multiple configurations including a meter only,  meter and probe,  and\n a complete package that includes bypass loop\n and panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI10053 Amplified pH\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe BL100 uses the HI10053 amplified probe that incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector. The built in amplifier helps to reduce electrical noise from recirculation pumps to provide for a stable,  reliable measurement. The pH glass used is ideal for low conductivity water and provides for fast response..\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL100-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line pH Controller and Dosing Pump - BL100-Meter and probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.10 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e User calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH) \u003cbr\u003eProcess calibration: single point, adjustable (±0.50 pH around measured pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 6.00 to 8.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Proportional Band\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0.10 to 2.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e adjustable 0.10 to 1.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0 °C (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5 °C (±0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e proportional and on\/off control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records a set of consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e external switches can be connected to hold the control due to external events (low reagent level, recirculation pump doesn't work)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted with built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e HI10053 pH\/temperature probe with quick connect DIN connector (supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F), max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL100-00 is supplied with BL100 controller, HI10053 pH\/temperature probe, 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003e\u003cbr\u003eBL100-10 is supplied with BL100 controller, HI10053 pH\/temperature probe, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003e\u003cbr\u003eBL100-20 is supplied with BL100 controller, HI10053 pH\/temperature probe, panel mounted flow cell assembly, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL100-00\"\u003ePool Line pH Controller and Dosing Pump - BL100-Meter and probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159026033,"sku":"BL100-00","price":39804.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl100-hi10053_flowcellprobe_1.jpg?v=1792645790"},{"product_id":"pool-line-orp-controller-and-dosing-pump-bl101-meter-and-probe","title":"Pool Line ORP Controller and Dosing Pump - BL101-Meter and probe - BL101-00","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eBL101 ORP Controller and Dosing Pump is a system engineered for maintaining the ORP of swimming pools,  hot tubs,  and spas. Typically liquid chlorine is used as a disinfectant to keep the water safe from harmful bacteria. Chlorine,  as an oxidizer,  will increase the oxidation- reduction potential (ORP) of water when it is added to it. When the ORP value is greater than 650mV then bacteria that are present will be killed within seconds. The BL101 was developed to be an inexpensive solution for the consumer to maintain the ideal ORP value at all times. Simply insert the probe and injection valve in-line with the re-circulation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL101.gif\" alt=\"\" width=\"1000\" height=\"1001\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe BL101 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth ORP (mV) and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level alarms for ORP. When an alarm is activated,  all dosing will stop. For added safety,  the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-flow.jpg\" alt=\"flow rate\" width=\"1000\" height=\"727\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate,  like the proportional band,  allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-proportional.jpg\" alt=\"Automatic Proportional Pump Control\" width=\"1000\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed,  will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-level.jpg\" alt=\" Acid Tank Level\/Flow Switch Input\" width=\"1000\" height=\"725\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOxidation Chemical Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL101 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ORP-peristaltic-pump.jpg\" alt=\"Pooline ORP Peristaltic Pump\" width=\"1000\" height=\"1000\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe BL101 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line. The loss of prime can be problematic with a diaphragm pump due to the gassing of chlorine.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have any gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Persitaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL100-HI10053_flowcellprobe.jpg\" alt=\"pH probe mounted in flow thorugh cell\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eORP electrode with flow cell\u003c\/h4\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe BL101 is available in multiple configurations including a meter only,  meter and probe,  and\n a complete package that includes bypass loop\nand panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI10053 ORP\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe BL101 uses the HI20083 amplified probe that incorporates both ORP and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL101-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line ORP Controller and Dosing Pump - BL101-Meter and probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e -2000 to 2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Calibration\u003c\/td\u003e\n\u003ctd\u003e process calibration: single point, adjustable (± 50 mV around measured ORP value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e High or Low Mode Operation \u003cbr\u003eHigh set point dosing is activated when reading is higher than set point \u003cbr\u003e Low set point dosing is activated when reading is lower than set point (dose oxidizer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e On\/Off control using adjustable set point (200 to 900 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Proportional Band\u003c\/td\u003e\n\u003ctd\u003e adjustable proportional band (10 to 200 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e adjustable hysteresis (10-100 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0 °C (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5 °C (±0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e proportional and on\/off control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records a set of consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e external switches can be connected to hold the control due to external events (low reagent level, recirculation pump doesn't work)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted with built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e selectable flow rate (0.5 to 3.5 L \/ hour; 0.13 to 0.96 g\/hour) \u003cbr\u003emanual control for pump priming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003e HI20083 ORP\/temperature probe with quick connect DIN connector (supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F), max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL101-00 is supplied with BL101 controller, HI20083 ORP\/temperature probe, ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003eBL101-10 is supplied with BL101 controller, HI20083 ORP\/temperature probe, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003eBL101-20 is supplied with BL101 controller, HI20083 ORP\/temperature probe, panel mounted flow cell assembly, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (15 m), tubing adapter 1\/2” - 6 mm with racord (2), ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL101-00\"\u003ePool Line ORP Controller and Dosing Pump - BL101-Meter and probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159189873,"sku":"BL101-00","price":39804.0,"currency_code":"INR","in_stock":true}]},{"product_id":"blackstone-1-5-l-h-chemical-dosing-pump-bl1-5","title":"Blackstone 1.5 L\/h Chemical Dosing Pump - BL1.5-2","description":"\u003ch5\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the\u003cbr\u003epercentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL1.5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 1.5 L\/h Chemical Dosing Pump - BL1.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e 250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 1.5 LPH (0.4 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 13 bar (188.5 psi), dosing frequency strokes per min : 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e Diaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL1.5-1\"\u003eBlackstone 1.5 L\/h Chemical Dosing Pump - BL1.5\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159550321,"sku":"BL1.5-2","price":23190.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_3.jpg?v=1792645794"},{"product_id":"blackstone-10-8-l-h-chemical-dosing-pump-bl10","title":"Blackstone 10.8 L\/h Chemical Dosing Pump - BL10-2","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/dosing_pump-page-001.jpg\" alt=\"dosing pump flow rate \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the\u003cbr\u003epercentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL10-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 10.8 L\/h Chemical Dosing Pump - BL10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 10.8 lph (2.9 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 3 bar (43.5 psi)\/ dosing frequency strokes per min 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e Diaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL10-1\"\u003eBlackstone 10.8 L\/h Chemical Dosing Pump - BL10\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159583089,"sku":"BL10-2","price":23190.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_1.jpg?v=1792645794"},{"product_id":"blackstone-15-2-l-h-chemical-dosing-pump-bl15","title":"Blackstone 15.2 L\/h Chemical Dosing Pump -BL15-2","description":"\u003ch5\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the\u003cbr\u003e\npercentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins, allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump, you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003e\nBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE, which unlike conventional laminated diaphragms, will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF, PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL15-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eBlackstone 15.2 L\/h Chemical Dosing Pump -BL15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003eapproximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e15.2 lph (4.0 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e1 bar (14.5 psi), dosing frequency strokes per min : 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003efibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eDiaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003epumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003emaximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220\/240 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapprox. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL7916-2 is supplied with 7 m (23') LPDE suction valves, polyethylene discharge tubing, 220V power cable and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL15-1\" target=\"_blank\" rel=\"noopener\"\u003eBlackstone 15.2 L\/h Chemical Dosing Pump -BL15\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162204529,"sku":"BL15-2","price":31306.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_4_1.jpg?v=1792645799"},{"product_id":"blackstone-18-3-l-h-chemical-dosing-pump-bl20","title":"Blackstone 18.3 L\/h Chemical Dosing Pump - BL20-2","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/dosing_pump-page-001.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the\u003cbr\u003epercentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL20-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 18.3 L\/h Chemical Dosing Pump - BL20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 1.5 LPH (0.4 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 13 bar (188.5 psi), dosing frequency strokes per min : 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e diaphragm in PTFE, glass ball valves and O-rings in FPM\/FKM, polyethylene 5 x 8 mm tubing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115; 50-60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL20-1\"\u003eBlackstone 18.3 L\/h Chemical Dosing Pump - BL20\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162597745,"sku":"BL20-2","price":31306.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_7.jpg?v=1792645801"},{"product_id":"blackstone-2-9-l-h-chemical-dosing-pump-bl3","title":"Blackstone 2.9 L\/h Chemical Dosing Pump -BL3-2","description":"\u003ch5\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the\u003cbr\u003epercentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL3-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 2.9 L\/h Chemical Dosing Pump -BL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e 250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 2.9 lph (0.8 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 8 bar (116 psi), dosing frequency strokes per min : 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e Diaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL3-1\"\u003eBlackstone 2.9 L\/h Chemical Dosing Pump -BL3\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162564977,"sku":"BL3-2","price":31306.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_9.jpg?v=1792645800"},{"product_id":"blackstone-5-l-h-chemical-dosing-pump-bl5","title":"Blackstone 5 L\/h Chemical Dosing Pump -BL5-2","description":"\u003ch5\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the percentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL5-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 5 L\/h Chemical Dosing Pump -BL5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e 250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 5.0 lph (1.3 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 7 bar (101.5 psi), dosing frequency strokes per min : 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e Diaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL5-1\"\u003eBlackstone 5 L\/h Chemical Dosing Pump -BL5\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162630513,"sku":"BL5-2","price":31306.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_11.jpg?v=1792645801"},{"product_id":"blackstone-7-6-l-h-chemical-dosing-pump-bl7","title":"Blackstone 7.6 L\/h Chemical Dosing Pump -BL7-2","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/dosing_pump-page-001.jpg\" alt=\"dosing pump flow rate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the percentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL7-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 7.6 L\/h Chemical Dosing Pump -BL7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e 250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 7.6 LPH (2.0 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e Diaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL7-1\"\u003eBlackstone 7.6 L\/h Chemical Dosing Pump -BL7\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162696049,"sku":"BL7-2","price":31306.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_1_2.jpg?v=1792645803"},{"product_id":"groline-ph-dosing-system-meter-and-probe-hi981412","title":"GroLine pH Dosing System-Meter and probe - HI981412-00","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline-peristaltic-pump.jpg\" alt=\"GroLine Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.\u003c\/p\u003e\n\u003ch4\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Flow Rate\u003c\/h4\u003e\n\u003cp\u003eThe dosing pump flow rate is adjustable from 0.5 to 3.5L\/h, allowing for better control in maintaining a desired set point.\u003c\/p\u003e\n\u003ch4\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eA connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMulticolored LCD Display\u003c\/h4\u003e\n\u003cp\u003eA multi-colored LCD provides a quick way to see the status of the pool controller. The display will show green when operation normally and red while in an alarm state.\u003c\/p\u003e\n\u003ch4\u003eIntuitive LCD\u003c\/h4\u003e\n\u003cp\u003eThe Quick Connect DIN connector creates a waterproof seal with the meter making it ideal for reducing electrical noise issues with the connection caused by humid environments.\u003c\/p\u003e\n\u003ch4\u003eGroLine pH\/Temperature Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI981412 uses the HI10063 amplified probe that incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in amplifier\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003e1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981412-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI981412 GroLine pH Dosing System-Meter and probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003euser calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH) process calibration: single point, adjustable (±0.50 pH around measured pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105°C (23.0 to 221.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eSPDT 2.5A \/ 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e910 g (32 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981412-00 is supplied with HI10063 pH\/temperature probe, 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe. HI981412-10 (with in-line mounting kit) is supplied with HI981412 controller, HI10063 pH\/temperature probe, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (2), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (5 m), valves (2), 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe. HI981412-20 (with flow-cell mounting kit) is supplied with HI981412 controller, HI10063 pH\/temperature probe, flow cell for HI981412\/BL101, mounting panel assembly for HI981412\/BL101, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (3), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (15 m), tubing adapter 1\/2” - 6 mm with racord (2), valves (2), 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981412-00\" target=\"_blank\" rel=\"noopener\"\u003eHI981412 GroLine pH Dosing System-Meter and probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451939185,"sku":"HI981412-00","price":54688.5,"currency_code":"INR","in_stock":true}]},{"product_id":"groline-ph-dosing-system-meter-probe-and-in-line-mounting-kit-hi981412","title":"GroLine pH Dosing System-Meter,  probe and in-line mounting kit - HI981412-10","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline-peristaltic-pump.jpg\" alt=\"GroLine Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.\u003c\/p\u003e\n\u003ch4\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Flow Rate\u003c\/h4\u003e\n\u003cp\u003eThe dosing pump flow rate is adjustable from 0.5 to 3.5L\/h,  allowing for better control in maintaining a desired set point.\u003c\/p\u003e\n\u003ch4\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eA connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMulticolored LCD Display\u003c\/h4\u003e\n\u003cp\u003eA multi-colored LCD provides a quick way to see the status of the controller. The display will show green when operation normally and red while in an alarm state.\u003c\/p\u003e\n\u003ch4\u003eIntuitive LCD\u003c\/h4\u003e\n\u003cp\u003eThe Quick Connect DIN connector creates a waterproof seal with the meter making it ideal for reducing electrical noise issues with the connection caused by humid environments.\u003c\/p\u003e\n\u003ch4\u003eGroLine pH\/Temperature Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI981412 uses the HI10063 amplified probe that incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in amplifier\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003e1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI981412-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI981412 GroLine pH Dosing System-Meter, probe and in-line mounting kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.10 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e user calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH)  process calibration: single point, adjustable (±0.50 pH around measured pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105°C (23.0 to 221.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e SPDT 2.5A \/ 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100-240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981412-00 is supplied with HI10063 pH\/temperature probe, 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe. HI981412-10 (with in-line mounting kit) is supplied with HI981412 controller, HI10063 pH\/temperature probe, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (2), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (5 m), valves (2), 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe. HI981412-20 (with flow-cell mounting kit) is supplied with HI981412 controller, HI10063 pH\/temperature probe, flow cell for HI981412\/BL101, mounting panel assembly for HI981412\/BL101, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (3), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (15 m), tubing adapter 1\/2” - 6 mm with racord (2), valves (2), 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI981412-10\"\u003eHI981412 GroLine pH Dosing System-Meter, probe and in-line mounting kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451971953,"sku":"HI981412-10","price":70776.45,"currency_code":"INR","in_stock":true}]},{"product_id":"groline-ph-dosing-system-meter-probe-and-panel-mounted-flow-cell-kit-hi981412","title":"GroLine pH Dosing System-Meter,  probe and panel mounted flow cell kit - HI981412-20","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline-peristaltic-pump.jpg\" alt=\"GroLine Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe powerful built-in peristaltic pump uses a stepper motor which does not have any gears or brushes providing for a long life with little maintenance.\u003c\/p\u003e\n\u003ch4\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Flow Rate\u003c\/h4\u003e\n\u003cp\u003eThe dosing pump flow rate is adjustable from 0.5 to 3.5L\/h,  allowing for better control in maintaining a desired set point.\u003c\/p\u003e\n\u003ch4\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eA connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMulticolored LCD Display\u003c\/h4\u003e\n\u003cp\u003eA multi-colored LCD provides a quick way to see the status of the pool controller. The display will show green when operation normally and red while in an alarm state.\u003c\/p\u003e\n\u003ch4\u003eIntuitive LCD\u003c\/h4\u003e\n\u003cp\u003eThe Quick Connect DIN connector creates a waterproof seal with the meter making it ideal for reducing electrical noise issues with the connection caused by humid environments.\u003c\/p\u003e\n\u003ch4\u003eGroLine pH\/Temperature Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI981412 uses the HI10063 amplified probe that incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eBuilt-in amplifier\u003c\/li\u003e\n\u003cli\u003ePVDF body\u003c\/li\u003e\n\u003cli\u003e1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI981412-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI981412 GroLine pH Dosing System-Meter, probe and panel mounted flow cell kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.10 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e user calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH)  process calibration: single point, adjustable (±0.50 pH around measured pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105°C (23.0 to 221.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5°C (±0.9°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVoltage Output\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e SPDT 2.5A \/ 230 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100-240 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F); max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981412-00 is supplied with HI10063 pH\/temperature probe, 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe. HI981412-10 (with in-line mounting kit) is supplied with HI981412 controller, HI10063 pH\/temperature probe, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (2), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (5 m), valves (2), 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe. HI981412-20 (with flow-cell mounting kit) is supplied with HI981412 controller, HI10063 pH\/temperature probe, flow cell for HI981412\/BL101, mounting panel assembly for HI981412\/BL101, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (3), aspiration PVC tube (flexible) (5 m), dispensing PE injection tube (rigid) (15 m), tubing adapter 1\/2” - 6 mm with racord (2), valves (2), 4.01 pH buffer solution, 20 mL (3), 7.01 pH buffer solution, 20 mL (3), power connection cable, instruction manual and quality certificates for instrument and probe.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI981412-20\"\u003eHI981412 GroLine pH Dosing System-Meter, probe and panel mounted flow cell kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871452037489,"sku":"HI981412-20","price":89603.55,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981412_2-720x720-2d9be2f8-d07b-46cf-a37e-912230996d2b.png?v=1792646891"},{"product_id":"groline-nutrient-dosing-system-meter-and-probe-hi981413","title":"Groline Nutrient Dosing System-Meter and probe - HI981413-00","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI981413 Nutrient Dosing System is engineered for maintaining the concentration of fertilizer nutrient solution used in hydroponics and irrigation water. The nutrient concentration in the water used for irrigation is critical for the successful propagation and growth of plants. The HI981413 uses an amperometric conductivity sensor for measuring the amount of fertilizer in the solution. The meter can be programmed to display results as EC (electrical conductivity) or as TDS (total dissolved solids). The EC results are displayed as mS\/cm while TDS is displayed as ppm with a selectable conversion factor from 0.45 to 0.99. The HI981413 was developed to be an inexpensive solution for the horticulturist to maintain the ideal fertilizer concentrations. Simply insert the probe and injection valve in-line with the re-circulation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe HI981413 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth conductivity or TDS and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high-level alarms for EC\/TDS. When an alarm is activated, all dosing will stop. For added safety, the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_flow.jpg\" alt=\"flow rate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_prop.jpg\" alt=\"Automatic Proportional Pump Control\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed, will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_level.jpg\" alt=\"Tank Level\/Flow Switch Input\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline-peristaltic-pump.jpg\" alt=\"GroLine Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe HI981413 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Peristaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413-HI30033_flowcellprobe.jpg\" alt=\"EC probe mounted in flow thorugh cell\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConductivity electrode with flow cell\u003c\/h4\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe HI981413 is available in multiple configurations including a meter only, meter and probe, and\u003cbr\u003e\na complete package that includes bypass loop\u003cbr\u003e\nand panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI30003 Amperometric Conductivity\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe HI981413 uses the HI30003 probe that incorporates both conductivity and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981413-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eGroline Nutrient Dosing System-Meter and probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eUser calibration: automatic, one-point with standard solution (1.41 or 5.00 mS\/cm)\nProcess calibration: single point, adjustable (±0.50 mS\/cm around measured value)\nThe corresponding value in TDS, depends on TDS factor used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 9900 ppm, depends on TDS factor\ni.e. with TDS factor 0.5, range 50 to 5000 ppm\nwith TDS factor 0.7, range 70 to 7000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003eβ can be set from 0%\/°C to 2.4%\/°C; default is 1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003eTDS factor selectable from 0.45 to 0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eon\/off control using adjustable set point (0.10 to 10.00 mS\/cm; 45 to 9900 ppm, depends on TDS factor)\nproportional control 0.10 to 10.00 mS\/cm; 45 to 9900 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Proportional Band\u003c\/td\u003e\n\u003ctd\u003e0.05 to 1.00 mS\/cm; 23 to 990 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e0.05 to 0.50 mS\/cm; 23 to 495 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0°C; 23.0 to 221.0°F*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C; 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003estartup delay timer at power-on (0 to 600 sec.)\nPump flow control 0.5 to 3.5 Liter\/hour (0.13 to 0.92 Gallon\/hour) and maximum output pressure 1 atm (14 psi)\nmanual control for pump priming (defined in setup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003etriggered after 5 sec. if the controller records consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eovertime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003egalvanically isolated external switches can be attached to stop the pump and activate the alarm (low reagent level) when the switch is open and level alarm is configured in Setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eintuitive alarm system, using red, yellow and green color coded backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003ewall mounted, built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max. 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e908 g (36 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981413-00 is supplied with HI981413 controller, HI30033 EC\/TDS\/temperature probe, HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003cbr\u003e\nHI981413-10 (with in-line mounting kit) is supplied with HI981413 controller, HI30033 EC\/TDS\/temperature probe, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (2), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (5 m), HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003cbr\u003e\nHI981413-20 (with flow-cell mounting kit) is supplied with HI981413 controller, HI30033 pH\/temperature probe, flow cell for HI981413, mounting panel assembly for HI981413, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (3), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (15 m), barbed tubing adapter 1\/2” - 6 mm with racord (2), flow cell valves (2), HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981413-00\" target=\"_blank\" rel=\"noopener\"\u003eGroline Nutrient Dosing System-Meter and probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871452103025,"sku":"HI981413-00","price":53735.4,"currency_code":"INR","in_stock":true}]},{"product_id":"groline-nutrient-dosing-system-meter-probe-and-in-line-mounting-kit-hi981413","title":"Groline Nutrient Dosing System-Meter,  probe and in-line mounting kit - HI981413-10","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI981413 Nutrient Dosing System is engineered for maintaining the concentration of fertilizer nutrient solution used in hydroponics and irrigation water. The nutrient concentration in the water used for irrigation is critical for the successful propagation and growth of plants. The HI981413 uses an amperometric conductivity sensor for measuring the amount of fertilizer in the solution. The meter can be programmed to display results as EC (electrical conductivity) or as TDS (total dissolved solids). The EC results are displayed as mS\/cm while TDS is displayed as ppm with a selectable conversion factor from 0.45 to 0.99. The HI981413 was developed to be an inexpensive solution for the horticulturist to maintain the ideal fertilizer concentrations. Simply insert the probe and injection valve in-line with the re-circulation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe HI981413 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth conductivity or TDS and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high-level alarms for EC\/TDS. When an alarm is activated,  all dosing will stop. For added safety,  the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_flow.jpg\" alt=\"flow rate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate,  like the proportional band,  allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_prop.jpg\" alt=\"Automatic Proportional Pump Control\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed,  will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_level.jpg\" alt=\"Tank Level\/Flow Switch Input\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline-peristaltic-pump.jpg\" alt=\"GroLine Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe HI981413 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Peristaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413-HI30033_flowcellprobe.jpg\" alt=\"EC probe mounted in flow thorugh cell\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConductivity electrode with flow cell\u003c\/h4\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe HI981413 is available in multiple configurations including a meter only,  meter and probe,  and\n a complete package that includes bypass loop\n and panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI30003 Amperometric Conductivity\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe HI981413 uses the HI30003 probe that incorporates both conductivity and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI981413-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Groline Nutrient Dosing System-Meter, probe and in-line mounting kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e 2% F.S. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e User calibration: automatic, one-point with standard solution (1.41 or 5.00 mS\/cm) \u003cbr\u003eProcess calibration: single point, adjustable (±0.50 mS\/cm around measured value)\u003cbr\u003eThe corresponding value in TDS, depends on TDS factor used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 9900 ppm, depends on TDS factor \u003cbr\u003ei.e. with TDS factor 0.5, range 50 to 5000 ppm\u003cbr\u003ewith TDS factor 0.7, range 70 to 7000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e 2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e β can be set from 0%\/°C to 2.4%\/°C; default is 1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e TDS factor selectable from 0.45 to 0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e on\/off control using adjustable set point  (0.10 to 10.00 mS\/cm; 45 to 9900 ppm, depends on TDS factor)\u003cbr\u003eproportional control 0.10 to 10.00 mS\/cm; 45 to 9900 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Proportional Band\u003c\/td\u003e\n\u003ctd\u003e 0.05 to 1.00 mS\/cm; 23 to 990 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e 0.05 to 0.50 mS\/cm; 23 to 495 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0°C; 23.0 to 221.0°F*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5°C; 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e startup delay timer at power-on (0 to 600 sec.) \u003cbr\u003ePump flow control 0.5 to 3.5 Liter\/hour (0.13 to 0.92 Gallon\/hour) and maximum output pressure 1 atm (14 psi) \u003cbr\u003emanual control for pump priming (defined in setup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e galvanically isolated external switches can be attached to stop the pump and activate the alarm (low reagent level) when the switch is open and level alarm is configured in Setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e intuitive alarm system, using red, yellow and green color coded backlight \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted, built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max. 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 908 g (36 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981413-00 is supplied with HI981413 controller, HI30033 EC\/TDS\/temperature probe, HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003cbr\u003eHI981413-10 (with in-line mounting kit) is supplied with HI981413 controller, HI30033 EC\/TDS\/temperature probe, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (2), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (5 m), HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003cbr\u003eHI981413-20 (with flow-cell mounting kit) is supplied with HI981413 controller, HI30033 pH\/temperature probe, flow cell for HI981413, mounting panel assembly for HI981413, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (3), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (15 m), barbed tubing adapter 1\/2” - 6 mm with racord (2), flow cell valves (2), HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI981413-10\"\u003eGroline Nutrient Dosing System-Meter, probe and in-line mounting kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871452135793,"sku":"HI981413-10","price":70776.45,"currency_code":"INR","in_stock":true}]},{"product_id":"groline-nutrient-dosing-system-meter-probe-and-panel-mounted-flow-cell-kit-hi981413","title":"Groline Nutrient Dosing System-Meter,  probe and panel mounted flow cell kit - HI981413-20","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI981413 Nutrient Dosing System is engineered for maintaining the concentration of fertilizer nutrient solution used in hydroponics and irrigation water. The nutrient concentration in the water used for irrigation is critical for the successful propagation and growth of plants. The HI981413 uses an amperometric conductivity sensor for measuring the amount of fertilizer in the solution. The meter can be programmed to display results as EC (electrical conductivity) or as TDS (total dissolved solids). The EC results are displayed as mS\/cm while TDS is displayed as ppm with a selectable conversion factor from 0.45 to 0.99. The HI981413 was developed to be an inexpensive solution for the horticulturist to maintain the ideal fertilizer concentrations. Simply insert the probe and injection valve in-line with the re-circulation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe HI981413 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth conductivity or TDS and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high-level alarms for EC\/TDS. When an alarm is activated,  all dosing will stop. For added safety,  the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_flow.jpg\" alt=\"flow rate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate,  like the proportional band,  allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_prop.jpg\" alt=\"Automatic Proportional Pump Control\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed,  will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline_level.jpg\" alt=\"Tank Level\/Flow Switch Input\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/groline-peristaltic-pump.jpg\" alt=\"GroLine Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe HI981413 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Peristaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981413-HI30033_flowcellprobe.jpg\" alt=\"EC probe mounted in flow thorugh cell\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConductivity electrode with flow cell\u003c\/h4\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe HI981413 is available in multiple configurations including a meter only,  meter and probe,  and  a complete package that includes bypass loop  and panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI30003 Amperometric Conductivity\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe HI981413 uses the HI30003 probe that incorporates both conductivity and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI981413-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Groline Nutrient Dosing System-Meter, probe and panel mounted flow cell kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e 2% F.S. \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e User calibration: automatic, one-point with standard solution (1.41 or 5.00 mS\/cm) \u003cbr\u003eProcess calibration: single point, adjustable (±0.50 mS\/cm around measured value)\u003cbr\u003eThe corresponding value in TDS, depends on TDS factor used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 9900 ppm, depends on TDS factor \u003cbr\u003ei.e. with TDS factor 0.5, range 50 to 5000 ppm\u003cbr\u003ewith TDS factor 0.7, range 70 to 7000 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e 2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e β can be set from 0%\/°C to 2.4%\/°C; default is 1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e TDS factor selectable from 0.45 to 0.99\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e on\/off control using adjustable set point  (0.10 to 10.00 mS\/cm; 45 to 9900 ppm, depends on TDS factor)\u003cbr\u003eproportional control 0.10 to 10.00 mS\/cm; 45 to 9900 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Proportional Band\u003c\/td\u003e\n\u003ctd\u003e 0.05 to 1.00 mS\/cm; 23 to 990 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e 0.05 to 0.50 mS\/cm; 23 to 495 ppm, depends on TDS factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0°C; 23.0 to 221.0°F*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5°C; 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e startup delay timer at power-on (0 to 600 sec.) \u003cbr\u003ePump flow control 0.5 to 3.5 Liter\/hour (0.13 to 0.92 Gallon\/hour) and maximum output pressure 1 atm (14 psi) \u003cbr\u003emanual control for pump priming (defined in setup)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e galvanically isolated external switches can be attached to stop the pump and activate the alarm (low reagent level) when the switch is open and level alarm is configured in Setup\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003e intuitive alarm system, using red, yellow and green color coded backlight \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted, built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max. 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 908 g (36 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981413-00 is supplied with HI981413 controller, HI30033 EC\/TDS\/temperature probe, HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003cbr\u003eHI981413-10 (with in-line mounting kit) is supplied with HI981413 controller, HI30033 EC\/TDS\/temperature probe, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (2), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (5 m), HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003cbr\u003eHI981413-20 (with flow-cell mounting kit) is supplied with HI981413 controller, HI30033 pH\/temperature probe, flow cell for HI981413, mounting panel assembly for HI981413, controller aspiration filter, controller injector, 1\/2” thread, saddle for Ø 50 mm pipe (3), PVC aspiration tubing (flexible) (5 m), PE rigid dispensing tubing (15 m), barbed tubing adapter 1\/2” - 6 mm with racord (2), flow cell valves (2), HI7031-012 conductivity calibration solution (1413 µS\/cm - 120 ml), plastic beaker, power connection cable, instruction manual and quality certificates for instrument and probe.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI981413-20\"\u003eGroline Nutrient Dosing System-Meter, probe and panel mounted flow cell kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871452168561,"sku":"HI981413-20","price":89603.55,"currency_code":"INR","in_stock":true}]},{"product_id":"groline-monitor-for-hydroponic-nutrients-threaded-probe-for-insertion-mounting-hi981421","title":"GroLine Monitor for Hydroponic Nutrients, Threaded probe for insertion mounting - HI981421-01","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981420_pH-ppm.jpg\" alt=\"groline monitor display\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOne quick glance is all it takes.\u003c\/h4\u003e\n\u003cp\u003eA large clear LCD displays all of your essential readings so you know what your hydroponic nutrients solution is doing 24\/7. High and low alarms flash warning you if something needs adjusting.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981420_24hrplot.jpg\" alt=\"groline monitor display\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMonitor changes over time.\u003c\/h4\u003e\n\u003cp\u003eThe GroLine Monitor automatically logs your results every 15 minutes over the last 30 days. Minimum, maximum, and average values are stored so you can recognize when patterns arise and help prevent future problems.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1285-8_tip.jpg\" alt=\"HI1285-5 pH\/EC\/TDS Multiparameter Probe\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOne probe. Three measurements.\u003c\/h4\u003e\n\u003cp\u003eOur 3-in-1 pre-amplified probe measures pH, EC\/TDS, and temperature in a single, durable, polypropylene body making the GroLine Monitor easy to handle and easy to set up.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981420_quick_calibration_groline.jpg\" alt=\"quick-calibration-groline\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eQuick Cal for less maintenance.\u003c\/h4\u003e\n\u003cp\u003eA single calibration solution for pH and conductivity makes calibration fast and ensures all of your measurements are accurate all of the time for better plant health and better yield.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e3 sensors combined in a single rugged probe body: pH electrode with renewable cloth junction, amperometric EC\/TDS sensor, and an internal temperature sensor for temperature compensated readings\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eIP65 rated enclosure: designed to withstand harsh grow environments\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eWide pH Range: measure pH from 0.00 to 14.00 pH\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eSelectable EC to TDS\/ppm conversion factor: choice of either a 0.5 or 0.7 conversion factor\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eAutomatic Temperature Compensation: all readings are compensated for variations in temperature, temperature displayed in ℃ or ℉ along with pH, EC or TDS reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eLarge LCD with plant-friendly green backlighting: LCD can display all three essential hydroponic nutrient measurements at one time, a 3-second cycle of single measurements, or a real-time graph screen with options for measurement selection and log recall\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eData logging for 30 days: logs every 15 minutes for last 30 days, stores min, max, and average values\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eData transfer: USB-C port for easy data transfer to memory stick or PC\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eHigh and low alarms: warns when your nutrient solution is out of desired range by flashing display and message\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eAmbient light sensor: for automatic LCD dimming\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981421-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eGroLine Monitor for Hydroponic Nutrients - HI981421-Threaded probe for insertion mounting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH; 0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH; 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH; ± 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone or two-point calibration (using pH 4.01,7.01, 10.01 buffers) using auto buffer recognition; one-point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic (0.0 to 60.0ºC\/ 32.0 to 140.0°)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1mS\/cm (0.00 to 5.00mS\/cm); ±0.2mS\/cm (5.00 to 10.00mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eone-point at 1.41 mS\/cm or 5.00 mS\/cm using auto standard recognition; one-point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5000 ppm (TDS conversion factor 0.5 (500 CF)); 0 to 7000 ppm (TDS conversion factor 0.7 (700 CF))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e10 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003eβ set at 1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003eTDS conversion factor 0.5 (500 CF); TDS conversion factor 0.7 (700 CF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003ehigh and low with enable\/disable option for all parameters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-parameter Probe\u003c\/td\u003e\n\u003ctd\u003eHI1285-8 pH\/EC\/TDS\/temperature polypropylene body, pre-amplified multiparameter probe with internal temperature sensor DIN connector and 2 m (6.6’) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eautomatic logging for last 30 days at 15 minute interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB Type-C for flash drive or compatible device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003elast 5 pH and EC calibrations\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel B\/W LCD with green backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e125 x 185 x 38 mm (4.92 x 7.28 x 1.49”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e333g ( 11.7oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981420 is supplied with: HI1285-8 multi-parameter probe, HI50036-0 Quick Cal buffer solution sachet (2), HI700661P electrode cleaning solution sachets for agriculture (2), 12VDC adapter, calibration certificates for both meter and probe, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981421-01\" target=\"_blank\" rel=\"noopener\"\u003eGroLine Monitor for Hydroponic Nutrients - HI981421-Threaded probe for insertion mounting\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871452496241,"sku":"HI981421-01","price":71652.6,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981421_groline-monitor_1_1.jpg?v=1792646898"}],"url":"https:\/\/hannainst.in\/collections\/dosing-pumps-process-control.oembed","provider":"hanna","version":"1.0","type":"link"}