{"title":"Industrial","description":"","products":[{"product_id":"marine-salinity-waterproof-tester-hi98319","title":"Marine Salinity Waterproof Tester - HI98319","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eSalinity measurements calculated from a conductivity measurement using known tables\u003c\/p\u003e\n\u003cp\u003eChoice of measurement units displayed in parts per thousand (ppt), Practical Salinity Units (PSU), or specific gravity (S.G.)\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eAmperometric graphite sensor reduces polarization effects and does not oxidize\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eDedicated calibration button with automatic recognition of the 35.00 ppt calibration solution in calibration mode\u003c\/p\u003e\n\u003cp\u003eSupplied complete with meter and calibration sachets in a durable plastic storage case.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Salinity Waterproof Tester - HI98319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 70.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1 ppt for 0.0 to 40.0 ppt; ±2 ppt for readings over 40.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003eall ranges calibrated with 35.00 ppt salinity standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 70.0 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 PSU for 0.0 to 40.0 PSU ; ±2 PSU for readings over 40.0 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Range\u003c\/td\u003e\n\u003ctd\u003e1.000 to 1.041 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.001 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5.0 to 50.0°C (41.0 to 122.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Method\u003c\/td\u003e\n\u003ctd\u003eppt - International Oceanographic Tables, 1966\nPSU - Standard Methods for the Examination of Water and Wastewater, 2520 B, Electrical Conductivity Method\nStandard Methods for the Examination of Water and Wastewater, 2520 C, Density Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C; 32.0 to 122.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C; ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable 8 minutes, 60 minutes, or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 3V lithium ion \/ approximately 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e68 g (2.4 oz.) without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98319 is supplied with protective cap, 35.00 ppt calibration solution sachet (4), CR2032 battery (1), plastic storage case, instrument quality certificate and instructional manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98319\" target=\"_blank\" rel=\"noopener\"\u003eMarine Salinity Waterproof Tester - HI98319\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871121965425,"sku":"HI98319","price":9363.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98319-angle-c.jpg?v=1792645678"},{"product_id":"orp-controller-and-pump-bl7917","title":"ORP Controller and Pump -  BL7917-2","description":"\u003ch4\u003eEasy Installation\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eDesigned with mounting holes built into a rugged base, BL7917 is simple to install. All of the controls and pump assemblies are conveniently located on the front of the unit.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eProportional Dosing\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eA proportional control slows down the stroke rate as the measured value approaches the user selectable set points, avoiding overdosage of chemicals. This feature makes the pump’s dosing more accurate, saves chemicals and eliminates unnecessary and costly corrections to your process, especially with slow reacting chemicals.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eRugged Construction\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eBL7917 is housed in rugged, fiber-reinforced polypropylene IP55 rated casings to protect from hazardous spills and splashes. PVDF, FPM\/FKM and PTFE materials are used for all parts that come into contact with liquid to resist corrosion caused by chemicals.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eIsolated Recorder Output\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eTo enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument’s 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eSimple Pump Action\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eA positive displacement solenoid with few moving parts makes the BL7916 more reliable than motor driven pumps since there is no rotating parts, gears or cams; drastically reducing any chance of mechanical failure.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eAuxiliary Dosing Contacts\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eAllows the user to attach a mixer or priming pump that is activated only when the pump is dosing.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL7917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eORP Controller and Pump - BL7917\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e-999 to +999 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mV @25°C\/77°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel Dosing Relay\u003c\/td\u003e\n\u003ctd\u003eby consent through level control contact\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003eproportional, oxidizing or reducing, user selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Terminals\u003c\/td\u003e\n\u003ctd\u003e1 isolated, 2A, max. 240V, resistive load, 1,000,000 strokes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e±200 mV from ORP dosing setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e4-20 mA (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eLCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e115V ±15%; 50\/60Hz (40W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e221 x 142 x 181 mm (8.7 x 5.6 x 7.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 5 kg (11 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL7917 is supplied with polyethylene tubing, discharge and suction valves, power cable and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL7917\" target=\"_blank\" rel=\"noopener\"\u003eORP Controller and Pump - BL7917\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871158960497,"sku":"BL7917-2","price":93982.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl7917_f_1.jpg?v=1792645788"},{"product_id":"wall-mounted-ph-controller-and-pump-bl7916","title":"Wall Mounted pH Controller and Pump - BL7916-2","description":"\u003ch4\u003eEasy Installation\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eDesigned with mounting holes built into a rugged base,  BL7916 is simple to install. All of the controls and pump assemblies are conveniently located on the front of the unit.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eProportional Dosing\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eA proportional control slows down the stroke rate as the measured value approaches the user selectable set points,  avoiding overdosage of chemicals. This feature makes the pump's dosing more accurate,  saves chemicals and eliminates unnecessary and costly corrections to your process,  especially with slow reacting chemicals.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eRugged Construction\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eBL7916 is housed in rugged,  fiber-reinforced polypropylene IP55 rated casings to protect from hazardous spills and splashes. PVDF,  FPM\/FKM and PTFE materials are used for all parts that come into contact with liquid to resist corrosion caused by chemicals.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eIsolated Recorder Output\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eTo enhance troubleshooting and the ability to record data while monitoring,  simply attach a recording device to the instrument's 4 to 20 mA output contacts,  conveniently located on the front panel,  to obtain a copy of the results on demand.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eSimple Pump Action\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eA positive displacement solenoid with few moving parts makes the BL7916 more reliable than motor driven pumps since there is no rotating parts,  gears or cams; drastically reducing any chance of mechanical failure.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eAuxiliary Dosing Contacts\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eAllows the user to attach a mixer or priming pump that is activated only when the pump is dosing.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL7916-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Wall Mounted pH Controller and Pump - BL7916\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e manual 1 or 2 point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e fixed by resistor; 2-wire pt100 optional\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e 10¹² Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e proportional, acid or base, user selectable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e manual adjustment through coarse\/fine trimmers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Proportional Band\u003c\/td\u003e\n\u003ctd\u003e fixed 1.5 pH unit band; adjustable by changing resistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLevel Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e dosing pump operated by consent feature through level input connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Terminals\u003c\/td\u003e\n\u003ctd\u003e Isolated, 2A, Max. 240V, resistive load, 1,000,000 strokes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e fixed; based on pH setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Range\u003c\/td\u003e\n\u003ctd\u003e activated when pH is outside 2 pH units from setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e 250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e 4 to 20 mA (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e segmented LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 115V ±15%; 50\/60Hz (40W)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 221 x 142 x 181 mm (8.7 x 5.6 x 7.1'')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e Approximately 5 kg (11 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL7916 is supplied with polyethylene tubing, discharge and suction valves, power cable and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL7916-1\"\u003eWall Mounted pH Controller and Pump - BL7916\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871158993265,"sku":"BL7916-2","price":93982.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-controller-and-pump-bl7916-1_3.jpg?v=1792645790"},{"product_id":"ph-mini-controller-with-analog-output-bl931700","title":"pH Mini Controller with Analog Output - BL931700-1","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL931700_angle.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eEnhanced Accuracy \u0026amp; Precision\u003c\/h4\u003e\n\u003cp\u003eThe BL931700 model offers a manual two-point calibration with pH values displayed out to two decimal places.\u003c\/p\u003e\n\u003ch4\u003eExternal Disabling Feature\u003c\/h4\u003e\n\u003cp\u003eA normally open contact may connect to a level controller or flow monitor. This safety feature may be used to prevent continuous dosing in the event of specific or undesired system conditions.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL931700 features a dosing relay which may be configured to dose above or below a user programmable pH setpoint.\u003c\/p\u003e\n\u003ch4\u003eSelectable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eThe mini controller may be programmed to deactivate a valve,  pump,  or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes.\u003c\/p\u003e\n\u003ch4\u003eSelectable Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch,  normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.”\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL931700_rear.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAnalog Output Communication\u003c\/h4\u003e\n\u003cp\u003eThe BL931700 features a 4 - 20 mA analog output for connection to a data logger,  chart recorder,  or other device.\u003c\/p\u003e\n\u003ch4\u003eMatching Pin Connection\u003c\/h4\u003e\n\u003cp\u003eAn included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.\u003c\/p\u003e\n\u003ch4\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe mini controller is protected for up to a 2A load from the connected pump or device.\u003c\/p\u003e\n\u003ch4\u003eEasy Peripheral Connection\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks provide for easy connection to power,  communication,  dosing control,  or sensors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL931700-web\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH Mini Controller with Analog Output - BL931700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, 2 points through offset and slope trimmers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e 10¹² Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e 4 to 20 mA, accuracy ±0.20 mA, 500 Ω maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e BL931700-0: 12 VDC adapter (included); \u003cbr\u003eBL931700-1: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e BL931700-0: 200 g (7.1 oz.);\u003cbr\u003eBL931700-1: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL931700-0 (12 VDC) and BL931700-1 (115\/230 VAC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL931700-web\"\u003epH Mini Controller with Analog Output - BL931700\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166136689,"sku":"BL931700-1","price":40657.95,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl931700_front.jpg?v=1792645810"},{"product_id":"waterproof-portable-ec-tds-resistivity-salinity-meter-hi98192","title":"Waterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.\u003c\/p\u003e\n\u003cp\u003eHI98192 has an expanded conductivity range from 0.000 µS\/cm to 1000 mS\/cm actual conductivity (400 mS\/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.\u003c\/p\u003e\n\u003cp\u003eHI98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.\u003c\/p\u003e\n\u003cp\u003eChoose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.\u003c\/p\u003e\n\u003ch5\u003eEC and TDS measurements are fully customizable and include:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eCell constant selection between 0.0 and 10.000\u003c\/li\u003e\n\u003cli\u003eSelection of linear or non-linear (natural water), or No temperature compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe temperature compensation coefficient range is configurable from 0.00 to 10.00%\/℃ with a choice of reference temperatures of 15℃, 20℃ and 25℃. The conductivity to TDS factor is adjustable from 0.40 and 1.00.\u003c\/p\u003e\n\u003cp\u003eThe HI98192 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.\u003c\/p\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.\u003c\/p\u003e\n\u003cp\u003eGLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.\u003c\/p\u003e\n\u003cp\u003eAccess help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.\u003c\/p\u003e\n\u003cp\u003eThe compact, durable HI720192 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter, probe, beakers and conductivity standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-1.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThree stages of conformity\u003c\/strong\u003e\nPerforms all 3 stages of USP water quality testing requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-2-guide.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eOn-screen guide\u003c\/strong\u003e\nUsers are provided with on-screen instructions for each USP stage\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-2-progress.jpg\" alt=\"USP 2 progress\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProgress bar\u003c\/strong\u003e\nDisplays progress towards meeting stage 2 stability requirements.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eCompact, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003eMethods\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eUSP \u0026lt;645\u0026gt; capable for checking the quality of water used in pharmaceutical manufacturing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eSalinity readings\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eSeawater salinity can be displayed as % NaCl, natural seawater scale (ppt) or practical salinity scale (PSU)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-ranging and fixed range options\u003c\/h5\u003e\n\u003ch5\u003eCalibration\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePerform up to a five point calibration for enhanced accuracy\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP Features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data provides calibration data including date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eAuto Hold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes first stable reading on the display\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003eTemperature compensation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eNo temperature compensation, linear temperature compensation and non-linear temperature compensation – ISO\/DIN 7888\u003c\/li\u003e\n\u003cli\u003eConfigurable linear temperature compensation coefficient range from 0.00 to 10.00%\/℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLog on Demand: Store measurement data at the press of a button\u003c\/li\u003e\n\u003cli\u003eInterval lot logging: Log measurements at a selectable interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via opto-isolated USB with optional HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003e100-hour battery life\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eApproximately 100 hours of continuous use (without backlight)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, Graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Environmental, pharmaceutical, plating, water treatment, food manufacturing, and water and wastewater\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/l18xilr9j4?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/b47438229e5b7d8641acbd496846c11c50147bcf.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWaterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 µS\/cm*; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm (actual conductivity; temperature compensated to 400 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.01 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic up to five points with seven memorized standards (0.00 µS\/cm, 84.0 µS\/cm, 1.413 mS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g\/L); 10.00 to 99.99 ppt (g\/L); 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm; 0.1 ppm; 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 mg\/L (ppm) or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003enoTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO\/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e15°C, 20°C and 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Multi-range Measurement Modes\u003c\/td\u003e\n\u003ctd\u003eautorange, autoend, lock and fixed range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003emax. one point only in % range (with HI7037 standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 (PSU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 80.00 (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω cm; 100 to 999 Ω cm; 1.00 to 9.99 KΩ cm; 10.0 to 99.9 KΩ cm; 100 to 999 KΩ cm; 1.00 to 9.99 MΩ cm; 10.0 to 100.0 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω cm; 1 Ω cm; 0.01 KΩ cm; 0.1 KΩ cm; 1 KΩ cm; 0.01 MΩ cm; 0.1 MΩ cm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±10 Ω or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2°C; ±0.4°F (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e\n\u003ctd\u003eHI763133, four ring conductivity\/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 100 hours of continuous use (without backlight), 25 hours with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 µS\/cm calibration solution (230 mL), HI7035M 111.8 mS\/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98192\" target=\"_blank\" rel=\"noopener\"\u003eWaterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170396529,"sku":"HI98192","price":103693.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98192_manual_1.jpg?v=1792645815"},{"product_id":"pure-water-tester-0-0-99-9-s-cm-hi98308","title":"Pure Water Tester (0.0 - 99.9 µS\/cm) - HI98308","description":"\u003cp\u003eThe HI98308 features an amperometric graphite electrode that provides better repeatability in measurements since they do not oxidize. An amperometric measurement of EC is based on Ohm's Law, I = V\/R, where R depends on the distance between two pins and their surface. Oxidation changes both the distance and surface, which will affect accuracy. The non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results. When calibration is needed, simply submerge the electrode tip into calibration solution and adjust the trimmer on the side of the tester.\u003c\/p\u003e\n\u003cp\u003eThe HI98308 uses a conductometric measurement to determine the purity of water. The HI98308 Pure Water Test (PWT) enables users to check the purity of distilled or demineralized water in laboratory or industrial environments. PWT is suited for fields such as printed circuit board washing, laundry, steam cleaning, checking car battery water and all areas where distilled, demineralized or pure water is used. This tester is housed in durable casing that provides excellent protection against harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eElectrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges on atomic or larger sized particles in a medium are moved under the influence of a potential difference. EC is a measure of concentration, however, it is non-specic for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na\u003csup\u003e+\u003c\/sup\u003e and Cl-. This is a simplified definition as the measurement is affected by many things such as the type of ionic compound(s) dissolved in the water; the ions mobility, the solution viscosity, temperature as well as concentration.\u003c\/p\u003e\n\u003cp\u003eElectrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. \"Conductance\" and \"Resistance\" depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are \"normalized\" terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna's meters provide these measurements also.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance:\u003c\/h4\u003e\n\u003cp\u003eOne-point calibration\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eCalibrate with 84 µS\/cm EC solution using a screwdriver\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eExposed Temperature Probe\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eFast response to changes in sample temperature\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC)\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eSamples automatically compensated for temperature variations\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eGraphite electrode\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eReduced polarization effects\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePure Water Tester (0.0 - 99.9 µS\/cm) - HI98308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, one point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 0 to 50°C (32 to 122°F) with β=2%\/°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e175 x 41 x 23 mm (6.9 x 1.6 x 0.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e95 g (3.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98308 is supplied with protective cap, calibration screwdriver (HI98308), batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98308\" target=\"_blank\" rel=\"noopener\"\u003ePure Water Tester (0.0 - 99.9 µS\/cm) - HI98308\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170462065,"sku":"HI98308","price":8601.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98308-pwt_1.jpg?v=1792645815"},{"product_id":"professional-waterproof-portable-ph-orp-ise-meter-hi98191","title":"Professional Waterproof Portable pH\/ORP\/ISE Meter - HI98191","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eFor the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable.\u003c\/p\u003e\n\u003cp\u003eHanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.\u003c\/p\u003e\n\u003cp\u003eThe HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g\/L, ppb, μg\/L, mg\/mL, M, mol\/L, mmol\/L, % w\/v, user defined) and has an expanded measuring range of 1.00 x 10\u003csup\u003e-7\u003c\/sup\u003e to 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e.\u003c\/p\u003e\n\u003cp\u003ePressing the \"AutoHold\" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An \"out of calibration range\" warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.\u003c\/p\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna's HI920015 micro USB cable and HI92000 software.\u003c\/p\u003e\n\u003cp\u003eAccess help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.\u003c\/p\u003e\n\u003cp\u003eThe high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eThe compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eSetup Screen\u003c\/strong\u003e\nOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\npH calibration features detailed CAL Check™ messages. Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGLP\u003c\/strong\u003e\nComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-ISE-Fluoride.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eISE Measurements\u003c\/strong\u003e\nThe HI98191 includes ISE measurements when used with our wide selection of ISE electrodes or a custom version.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003epH CAL Check™\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/li\u003e\n\u003cli\u003eDisplays overall probe condition based on offset and slope after calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eISE direct concentration readout in a choice of concentration units\u003c\/h5\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003ch5\u003eFive-point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes a stable reading on the display for recording or logging\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data including date, time, calibrated values, slope and offset (pH)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200-hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Food \u0026amp; Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/1pmzf9o20h?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/2872b8cf233378bfb91dce12e7b14732390aacd8.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eProfessional Waterproof Portable pH\/ORP\/ISE Meter - HI98191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e10¹² Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003efrom 1.00 E⁻⁷ to 9.99 E¹⁰ concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e3 digits 0.01; 0.1; 1; 10 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading (monovalent ions), ±1% of reading (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.8°F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI72911B Titanium body, pH electrode with internal temperature sensor, BNC connector and 1 m (3.3’ cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e300 samples (100 each range pH, mV and ISE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98191 is supplied with HI72911B titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720191 hard carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98191\" target=\"_blank\" rel=\"noopener\"\u003eProfessional Waterproof Portable pH\/ORP\/ISE Meter - HI98191\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871192252785,"sku":"HI98191","price":94938.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98191_manual.jpg?v=1792645854"},{"product_id":"halo-bluetooth-wireless-ph-meter-for-flat-surfaces-hi14142","title":"HALO®  Bluetooth® Wireless pH Meter for Flat Surfaces  - HI14142","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eDownload the FREE app and try before you buy!\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.hannainst.hannalab\u0026amp;hl=en\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Google.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/itunes.apple.com\/us\/app\/hanna-lab\/id913755813?ls=1\u0026amp;mt=8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Apple.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Skin_Halo_Tip.png\" alt=\"HALOTM - Flat tip pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe HALO® Wireless pH Meter for Flat Surfaces incorporates Bluetooth® Smart technology with an application-specific design. There are several features that make it ideal for measuring the pH of agar plates,  skin,  or leather,  by providing a flat glass tip that allows a larger surface area than a typical pH electrode..\u003c\/p\u003e\n\u003ch5\u003eFlat Tip Bulb\u003c\/h5\u003e\n\u003cp\u003eThe flat shaped tip design allows for easy measurement on surfaces (such as agar plates,  skin,  leather,  paper,  and samples that cannot easily be penetrated) or samples with a small volume.\u003c\/p\u003e\n\u003ch5\u003eLow Temperature Glass Formulation\u003c\/h5\u003e\n\u003cp\u003eLow Temperature (LT) glass Low temperature glass for fast stabilization and more accurate results at lower temperatures. This is beneficial since many food products are stored at low temperatures.\u003c\/p\u003e\n\u003ch5\u003eOpen Junction Design\u003c\/h5\u003e\n\u003cp\u003eThe open junction design consists of a solid gel (viscolene) interface between the sample and internal reference. This interface not only prevents silver from entering the sample,  but also makes it impermeable to clogging from food products,  maintaining a fast response and stable reading.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Free Gel-filled Reference\u003c\/h5\u003e\n\u003cp\u003eBecause the internal reference is gel,  there is no fill solution to replenish as the probe is used. Other than routine calibration and cleaning,  this a maintenance free probe.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Temperature Sensor\u003c\/h5\u003e\n\u003cp\u003eThe thermistor temperature sensor built into the tip of the pH electrode. A thermistor based temperature sensor provides for a high accuracy temperature while being in the tip of the electrode allows for a rapid temperature compensated measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-hanna-lab-ipad-iphone.jpg\" alt=\"HALOTM - pH Probe with Bluetooth Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo2.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReal-Time Data\u003c\/h4\u003e\n\u003cp\u003eDisplay of beer pH and temperature updated every second. Readings are automatically saved to a history file every hour,  limited only by the available memory on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo3.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFluid,  Dynamic Graphing\u003c\/h4\u003e\n\u003cp\u003eMeasurements can be displayed alone on the display,  with tabulated data,  or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/appenabledthm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP (Good Laboratory Practice)\u003c\/h4\u003e\n\u003cp\u003eDisplays date and time of current calibration,  offset,  and average slope,  along with calibrated buffers,  mV values,  temperature and slopes between each buffer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11312hand.jpg\" alt=\"HALO pH probe features\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-alarm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-share.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog \u0026amp; Share Data\u003c\/h4\u003e\n\u003cp\u003eSaved log files may be annotated with measurement-specific information. Data is easily shared via email in CSV format.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-help.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp \u0026amp; Tutorials\u003c\/h4\u003e\n\u003cp\u003eDemo mode helps you explore features of the Hanna Lab App. General app information,  HALO information,  pH tutorial,  maintenance tutorial,  and contact information are available in help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHALO Features\/Benefits:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConnects to Hanna Lab App with a compatible Apple or Android Device via Bluetooth Smart Technology (Bluetooth 4.0)\u003cbr\u003eUp to five-point pH calibration with seven standard pH buffers available\u003cbr\u003eCalibration reminder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts you when HALO pH meter for beer needs calibration\u003c\/li\u003e\n\u003cli\u003eAppropriate preprogrammed calibration buffer set for application specific Halo pH electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eReal-time data\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays pH and temperature updated every second\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBasic Good Laboratory Practice (GLP)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration along with offset and average slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFull GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration,  offset and average slope along with calibrated buffers,  mV values,  temperature and slopes between each buffer\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFluid,  dynamic graphing\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMeasurement alarms\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts you if the measurement threshold is exceeded\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne button sample tagging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePressing either the icon in the Hanna Lab App or button on the HALO will tag sample data for easy reference\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eData logging with custom annotations\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSaved log files may be annotated with measurement specific information\u003c\/li\u003e\n\u003cli\u003eData is autosaved every hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFour ways to save and share data:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll data since last autosave\u003c\/li\u003e\n\u003cli\u003eAnnotations only\u003c\/li\u003e\n\u003cli\u003eAll data within a timed interval\u003c\/li\u003e\n\u003cli\u003eAnnotations only within a timed interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eShare data via email in CSV format\u003cbr\u003e\u003cbr\u003eHelp and tutorials:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDemo mode to help explore features of the Hanna Lab App\u003c\/li\u003e\n\u003cli\u003eGeneral app information\u003c\/li\u003e\n\u003cli\u003eGeneral HALO information\u003c\/li\u003e\n\u003cli\u003epH tutorial\u003c\/li\u003e\n\u003cli\u003eMaintenance tutorial\u003c\/li\u003e\n\u003cli\u003eContact information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility:\u003c\/h2\u003e\n\u003ch5\u003eHALO is compatible with the following devices:\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eAndroid\u003c\/strong\u003e\u003cbr\u003eCompatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eiOS\u003c\/strong\u003e\u003cbr\u003eiPad (3rd generation or newer)\u003cbr\u003eiPhone (4S or newer)\u003cbr\u003eiPod Touch (5th generation or newer)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eHI2202 edge\u003csup\u003eblu\u003c\/sup\u003e Meter\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eInformation about which products have Bluetooth Smart Technology (4.0),  also known as low energy (LE),  can be found \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/List_of_iOS_devices\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI14142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HALO\u003csup\u003e®\u003c\/sup\u003e  Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless pH Meter for Flat Surfaces  - HI14142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 12.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e Viscolene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e Low Temperature (LT) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e flat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 12 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 50 mm \/ 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm (glass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e Bluetooth Smart (Bluetooth 4.0), 10 m (33') range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e CR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e flat surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e  -2.000 to 16.000 pH \u003cbr\u003e ±800 mV \u003cbr\u003e-20.0 to 120.0 ºC *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1, 0.01, 0.001 pH \u003cbr\u003e 1, 0.1 mV\u003cbr\u003e0.1 ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e ±0.005 pH \u003cbr\u003e ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e up to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffers\u003c\/td\u003e\n\u003ctd\u003e 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from -5.0 to 100.0 ºC \/ 23.0 to 212.0 ºF *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\/System Requirements\u003c\/td\u003e\n\u003ctd\u003e  Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownload Information\u003c\/td\u003e\n\u003ctd\u003e Hanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI14142 (HALO) is supplied with storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, battery, quality certificate and instruction sheet. Smartphone and tablet not included.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI14142\"\u003eHALO\u003csup\u003e®\u003c\/sup\u003e Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless pH Meter for Flat Surfaces - HI14142\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871229411697,"sku":"HI14142","price":30673.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-calibration-reminder-and-ph-measurement-alarms-ipad-screen-hanna-lab-app_9.jpg?v=1792645899"},{"product_id":"t-shaped-celsius-thermometer-125mm-hi145-00","title":"T-Shaped Celsius Thermometer (125mm) - HI145-00","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion, such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on, a calibration test is immediately performed. With this unique feature, the HI145 series performs a self-check of its calibration status and displays it on the LCD, ensuring accuracy, repeatability, and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations, making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 125 mm (5\") long AISI 316 stainless steel probe. The sharp conical tip provides fast response and improved accuracy over the entire range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI145-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eT-Shaped Celsius Thermometer (125mm) - HI145-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-50.0 to 220°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (-50.0 to 199.9°C); 1°C (200 to 220°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3°C (-20 to 90°C); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e92 x 165 x 38 mm (3.6 x 6.5 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e65 g (2.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-00 is supplied complete with 125 mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI145-00\" target=\"_blank\" rel=\"noopener\"\u003eT-Shaped Celsius Thermometer (125mm) - HI145-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871229542769,"sku":"HI145-00","price":6195.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145_1.jpg?v=1792645902"},{"product_id":"t-shaped-fahrenheit-thermometer-125mm-hi145-01","title":"T-Shaped Fahrenheit Thermometer (125mm) - HI145-01","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion,  such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on,  a calibration test is immediately performed. With this unique feature,  the HI145 series performs a self-check of its calibration status and displays it on the LCD,  ensuring accuracy,  repeatability,  and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations,  making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 125 mm (5\") long AISI 316 stainless steel probe. The sharp conical tip provides fast response and improved accuracy over the entire range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI145-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e T-Shaped Fahrenheit Thermometer (125mm) - HI145-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -58.0 to 428°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°F (-58.0 to 199.9°F); 1°F (200 to 428°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.6°F (-4 to 194°F); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 92 x 165 x 38 mm (3.6 x 6.5 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 65 g (2.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-01 is supplied complete with 125 mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI145-01\"\u003eT-Shaped Fahrenheit Thermometer (125mm) - HI145-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871229575537,"sku":"HI145-01","price":6195.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-01_hi145-30_face_1.jpg?v=1792645903"},{"product_id":"t-shaped-celsius-thermometer-300mm-hi145-20","title":"T-Shaped Celsius Thermometer (300mm) - HI145-20","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion, such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on, a calibration test is immediately performed. With this unique feature, the HI145 series performs a self-check of its calibration status and displays it on the LCD, ensuring accuracy, repeatability, and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations, making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 300 mm (12\") long AISI 316 stainless steel probe, ideal for monitoring hot liquids, such as in deep frying and soup preparation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI145-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eT-Shaped Celsius Thermometer (300mm) - HI145-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-50.0 to 220°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (-50.0 to 199.9°C); 1°C (200 to 220°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3°C (-20 to 90°C); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e92 x 340 x 38 mm (3.6 x 13.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e80 g (2.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-20 is supplied complete with 300mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI145-20\" target=\"_blank\" rel=\"noopener\"\u003eT-Shaped Celsius Thermometer (300mm) - HI145-20\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871230984561,"sku":"HI145-20","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-20_2.jpg?v=1792645903"},{"product_id":"t-shaped-fahrenheit-thermometer-300mm-hi145-30","title":"T-Shaped Fahrenheit Thermometer (300mm) - HI145-30","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion,  such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on,  a calibration test is immediately performed. With this unique feature,  the HI145 series performs a self-check of its calibration status and displays it on the LCD,  ensuring accuracy,  repeatability,  and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations,  making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 300 mm (12\") long AISI 316 stainless steel probe,  ideal for monitoring hot liquids,  such as in deep frying and soup preparation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI145-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e T-Shaped Fahrenheit Thermometer (300mm) - HI145-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -58.0 to 428°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°F (-58.0 to 199.9°F); 1°F (200 to 428°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.6°F (-4 to 194°F); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 92 x 340 x 38 mm (3.6 x 13.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 80 g (2.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-30 is supplied complete with 300mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI145-30\"\u003eT-Shaped Fahrenheit Thermometer (300mm) - HI145-30\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871233573233,"sku":"HI145-30","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-30.jpg?v=1792645910"},{"product_id":"pronto-water-resistant-wall-mounted-precision-thermometer-c-hi146-00","title":"Pronto Water-resistant Wall-Mounted Precision Thermometer (°C)  HI146-00","description":"\u003cp\u003eThe HI146-00 is a high accuracy thermometer with a professional grade probe and a flexible 2 m cable.\u003c\/p\u003e\n\u003cp\u003eThe CAL CHECK® feature is incorporated into its function to allow you to confirm the accuracy of the meters any time. You can monitor the exact temperature of any product continuously and easily observe it on the LCD display.\u003c\/p\u003e\n\u003cp\u003eHI-146-00 can be easily carried from station to station or installed in a fixed position using the moulded eye and a wall mount probe holder.\u003c\/p\u003e\n\u003cp\u003eWith its compact and simplified design featuring a fixed stainless steel probe and optional probe holder,  this thermometer is ideal for monitoring the temperatures of liquids,  semi-solids and refrigerated foods.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKey features\u003c\/li\u003e\n\u003cli\u003eHACCP compliant\u003c\/li\u003e\n\u003cli\u003eCAL CHECK® feature\u003c\/li\u003e\n\u003cli\u003eStainless steel temperature probe\u003c\/li\u003e\n\u003cli\u003eWater resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI146-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pronto Water-resistant Wall-Mounted Precision Thermometer (°C)  HI146-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -50.0 to 150.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.3°C (-20 to 90°C); ±0.5°C (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e stainless steel probe (fixed) with 2 m (6.6’) cable; 160 x dia 3 mm (6.3 x dia 0.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AA \/ approximately 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e IP54; 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 86 x 110 x 43 mm (3.4 x 4.3 x 1.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI146-00 (Pronto) is supplied with stainless steel temperature probe, battery and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI146-00\"\u003ePronto Water-resistant Wall-Mounted Precision Thermometer (°C) HI146-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871233606001,"sku":"HI146-00","price":9924.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi146_2.jpg?v=1792645909"},{"product_id":"professional-waterproof-portable-ph-orp-meter-hi98190","title":"Professional Waterproof Portable pH\/ORP Meter - HI98190","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eFor the measurement of pH, the HI98190 handheld pH meter comes with an HI12963 titanium body amplified pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium probe body is chemically resistant to aggressive chemicals and is virtually unbreakable. The HI12963 pH\/temperature electrode features a newly designed Quick Connect DIN connector that provides a simple waterproof connection without any threads.\u003cbr\u003e\u003cbr\u003eHanna's unique CAL Check™ feature alerts the user to potential problems during the calibration process. By comparing previous calibration data to the current calibration, the meter will alert the user with display prompts when the probe needs to be cleaned or is broken, and if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. Calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.\u003cbr\u003e\u003cbr\u003ePressing the \"AutoHoldin. virtual key seen in measurement mode, the portable ph meter will freeze a stable reading, allowing for the reading to be documented or logged. An \"out of calibration rangein. warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.\u003cbr\u003e\u003cbr\u003eThe log-on-demand mode allows the user to record and save up to 200 samples (100 for pH and 100 for mV). This data, along with the associated GLP data, can then be transferred to a PC with Hanna's HI920015 micro USB cable and HI92000 software.\u003cbr\u003e\u003cbr\u003eThe high contrast graphic LCD is easy to read outdoors in bright sunlight as well as in low-lit areas with the use of the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.\u003cbr\u003e\u003cbr\u003eThe compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions, cleaning solutions, and storage solutions.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSetup screen\u003c\/h4\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-CAL.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration\u003c\/h4\u003e\n\u003cp\u003epH calibration features detailed CAL Check™ messages. Users are guided through the calibration procedure with step-by-step on-screen instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP\u003c\/h4\u003e\n\u003cp\u003eComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003epH CAL Check™\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/li\u003e\n\u003cli\u003eDisplays overall probe condition based on offset and slope after calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003ch5\u003eFive-point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold - freezes reading on display upon stabilization\u003c\/h5\u003e\n\u003ch5\u003eGLP features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data including date, time, pH calibration buffers, offset and slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200 hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Food \u0026amp; Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental\u003c\/p\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cdiv style=\"position: relative; max-width: 100%; margin: 0 0 32px;\"\u003e\u003cvideo style=\"width: 100%; aspect-ratio: 16 \/ 9; height: auto; border: 0;\" src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/92c2819bf7a34a3cbb71080a6ee9cf37.mp4\" controls=\"controls\" playsinline=\"\"\u003e\n\u003c\/video\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003esku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH \/ -2.00 to 20.00 pH \/ -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Accuracy @ 25°C \/ 77°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH \/ ±0.01 pH \/ ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C (-4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Accuracy @ 25°C \/ 77°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 °C (±0.8 °F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eLog Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn demand, 200 samples (100 pH and 100 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC Connectivity - opto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eGLP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 to 50 °C (32 to 122 °F) max. RH 100% IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e407 g (14.2 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98190 is supplied with HI12963 titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720190 hard carrying case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eRecommended Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI12963 Titanium body, pH electrode with internal temperature sensor, quick DIN connector and 1 m (3.3' cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cp\u003eHI98190 is supplied with HI12963 titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720190 hard carrying case.\u003c\/p\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn2.hubspot.net\/hubfs\/2134380\/product-manuals\/MAN98191_05_19.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProfessional Waterproof Portable pH\/ORP Meter - HI98190\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871241503089,"sku":"HI98190","price":82815.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98190_1.jpg?v=1792645919"},{"product_id":"mini-titrator-for-measuring-titratable-alkalinity-in-water-and-wastewater-hi84531","title":"Mini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eAlkalinity is the ability of water to neutralize acids. Total titratable alkalinity is a measure of primarily three types of alkalinities present in a water sample: hydroxides, carbonates, and bicarbonates. Alkalinity in water can be the result of contributions from common chemicals including carbonates, bicarbonates, hydroxides, phosphates, borate and organic acid salts.\u003c\/p\u003e\n\u003cp\u003eThe alkalinity of a water sample indicates its ability to resist pH change. The amount of alkalinity in water is mostly due to the bicarbonate\/carbonate present. A low alkalinity level indicates that the water is susceptible to pH changes, while a high alkalinity level indicates that the water will be able to resist pH changes. Alkalinity can also be used to determine the corrosive capacity of water and can provide an estimation of water hardness.\u003c\/p\u003e\n\u003ch5\u003eDouble Junction pH Electrode\u003c\/h5\u003e\n\u003cp\u003eThe HI84531 is supplied with the HI1131B refillable, double junction, combination pH electrode. By design, the HI1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for direct measurements or acid base titrations in the water industry.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84531 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 600 rpm, regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Help.jpg\" alt=\"titrator screenshot\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Interface\u003c\/strong\u003eThe HI84531 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-Titration-Results.jpg\" alt=\"Titrate LR \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84531-TitrationCurve_400x201_1.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGraphic Mode \u003c\/strong\u003e This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Log.jpg\" alt=\"mini titrator acidity logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eLog-on-Demand\u003c\/strong\u003eThe HI84531 allows for data logging of up to 400 samples: 200 titration results and 200 pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-pH-Electrode-Condition.jpg\" alt=\"mini titrator pH mv meter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003e In addition to being an automatic titrator, the HI84531 also can be used as a pH\/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-CALCheck.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003eAccuracy is always ensured with Hanna's unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty\/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84531 is used as a pH meter, but also an accurate titration since the endpoint of a titratable alkalinity titration is determined by a set pH value.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI84531-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone, two or three-point calibration; four available buffers (4.01, 7.01, 8.30, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003eacid-base titration (strong alkalinity\/total alkalinity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eendpoint titration: 8.30 pH (phenolphthalein) \/ 4.50 pH (bromcresol green-methyl red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 30.0 to 400.0 mg\/L; 0.6 to 8.0 meq\/L\nHigh Range: 300 to 4000 mg\/L; 6.0 to 80.0 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.1 mg\/L (ppm); 0.1 meq\/L; High Range: 1 mg\/L (ppm); 0.1 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±1 mg\/L or 3% of reading, whichever is greater\nHigh Range: ±10 mg\/L or 3% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003eLow Range: 50 mL; High Range: 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eHI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer at 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84531 is supplied with HI1131B pH electrode, HI7662-M temperature probe, HI84531-50 low range titrant (120 mL), HI84531-51 high range titrant (120 mL), HI84531-55 calibration standard (230 mL), 100 mL beakers (2), dosing pump valve, 5 mL syringe, 2000 µL automatic pipette with two plastic tips, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, power adapter, instruction manual and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI84531-01\" target=\"_blank\" rel=\"noopener\"\u003eMini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871244550513,"sku":"HI84531-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84531_1.jpg?v=1792645926"},{"product_id":"amplified-amphel-ph-general-purpose-electrode-hi2910b-5","title":"Amplified AmpHel® pH General Purpose Electrode – HI2910B\/5","description":"\u003cp\u003eAmpHel® pH Electrode with Internal Battery,  PEI body,  gel electrolyte\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI2910B\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Amplified AmpHel\u003csup\u003e®\u003c\/sup\u003e pH General Purpose Electrode – HI2910B\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e Cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e Gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e General Purpose (-5 to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 3 bar (43.5 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 148.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI2910B\/5\"\u003eAmplified AmpHel\u003csup\u003e®\u003c\/sup\u003e pH General Purpose Electrode – HI2910B\/5\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248613745,"sku":"HI2910B\/5","price":22908.15,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2910b-1461x1472-9939f2f1-7d67-4bc5-9c9f-e815a61d88be.jpg?v=1792645932"},{"product_id":"ph-orp-temperature-combo-tester-hi98121","title":"pH\/ORP\/Temperature Combo Tester - HI98121","description":"\u003cp\u003eThe HI98121 is a lightweight ergonomically designed tester. This tester is designed to float making it ideal for taking readings virtually anywhere. With the HI98121 it is possible to monitor both pH and ORP at the same time. The HI98121 is commonly used to monitor pH and chlorine for many applications including swimming, food sanitization, plating wastewater treatment, and cooling tower water treatment.\u003c\/p\u003e\n\u003cp\u003eBy definition pH is the measurement of the voltage generated by an electrochemical cell at zero current. The potential generated is proportional to the thermodynamic activity of the ion being measured.\u003c\/p\u003e\n\u003cp\u003eSimilar to a pH measurement that quantifies the how acidic or alkaline solutions are, ORP (Oxidation Reduction Potential) measurements quantify the overall state of a solution as having the ability to oxidize or reduce a chemical species. Oxidizing and reducing reagents are used to participate in chemical reactions known as a redox reaction.\u003c\/p\u003e\n\u003cp\u003eAn ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWaterproof\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eHOLD feature\u003c\/li\u003e\n\u003cli\u003eSimple to use\u003c\/li\u003e\n\u003cli\u003eEconomical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003epH\/ORP\/Temperature Combo Tester - HI98121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic for pH readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 replaceable pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003efixed ORP sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98121 (ORP\/pH) is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98121\" target=\"_blank\" rel=\"noopener\"\u003epH\/ORP\/Temperature Combo Tester - HI98121\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871251431793,"sku":"HI98121","price":23427.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98121.jpg?v=1792645946"},{"product_id":"silica-high-range-checker-hc-hi770","title":"Silica High-Range Checker® HC - HI770","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI770 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure silica. Silica is found in all natural surface and saline waters in the dissolved form. Due to the potential to cause scaling, it is undesirable and therefore monitored in industrial applications, and heating and reverse osmosis systems. Designed as a more accurate alternative to chemical test kits, the HI770 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Industrial, Aquariums\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSilica High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA method 370.1 for drinking, surface and saline waters and Standard Method 4500-SiO₂ C for domestic and industrial waters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI770 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, silica HR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI770\" target=\"_blank\" rel=\"noopener\"\u003eSilica High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI770\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871255986545,"sku":"HI770","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi770-checkerhc-front.jpg?v=1792645964"},{"product_id":"silica-low-range-checker-hc-hi705","title":"Silica Low-Range Checker® HC - HI705","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI705 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure silica. Silica is found in all natural waters in the dissolved form. Due to the potential to cause scaling, it is undesirable and therefore monitored in industrial applications, and in heating and reverse osmosis systems. Designed as a more accurate alternative to chemical test kits, the HI705 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e* To zero 6 drops of reagent A and one packet of reagent B are added to the sample to be tested.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSilica Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the ASTM D859, heteropoly blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI705 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) cuvettes with caps, silica LR reagent starter kit for 12 tests (1 bottle of reagent A, 12 packets of reagent B, and 12 packets of reagent C), battery, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI705\" target=\"_blank\" rel=\"noopener\"\u003eSilica Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI705\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871256019313,"sku":"HI705","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi705-checkerhc-front_1.jpg?v=1792645965"},{"product_id":"combo-ph-conductivity-tds-tester-low-range-hi98129","title":"Combo pH\/Conductivity\/TDS Tester (Low Range) - HI98129","description":"\u003cp\u003eThe HI98129 is a highly accurate, waterproof pH meter that can also measure EC\/TDS in the low range (0 to 3999 µS\/cm EC\/ 0 to 2000 ppm TDS) and temperature. This floating, waterproof combination tester has an easy to read, LCD and an automatic shut-off. In addition, pH and EC\/TDS readings are automatically temperature compensated (ATC) to prevent temperature-related variations in your measurements. For EC\/TDS readings, the EC\/TDS conversion factor (CONV) is selectable by the user, as well as the temperature compensation coefficient β (BETA).\u003c\/p\u003e\n\u003ch4\u003eReplaceable pH Electrode Cartridge\u003c\/h4\u003e\n\u003cp\u003eThe HI98129 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!\u003c\/p\u003e\n\u003ch4\u003eHigh Accuracy EC\/TDS Graphite Probe\u003c\/h4\u003e\n\u003cp\u003eThe graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e3 sensors in a single meter\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH electrode with extractable junction\u003c\/p\u003e\n\u003cp\u003eAmperometric EC\/TDS sensor\u003c\/p\u003e\n\u003cp\u003eExposed temperature probe for faster EC\/TDS readings\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWaterproof\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDesigned to float if accidently dropped in sample\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWide pH Range\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH range is from 0.00 to 14.00 pH\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSelectable EC to TDS conversion factor\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eChoice of either a 0.45 or 1.0 conversion factor\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAutomatic Temperature Compensation\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAll readings are compensated for variations in temperature\u003c\/p\u003e\n\u003cp\u003eTemperature displayed in ℃ or ℉ along with pH, EC or TDS reading\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eStability indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHOLD button\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eFreezes reading on the display to allow recording of measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBEPS (Battery Error Prevention System\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBattery % level at startup\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAuto-off feature automatically shuts off meter after 8 minutes of non-use to maximize battery life\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCombo pH\/Conductivity\/TDS Tester (Low Range) - HI98129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 1382 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic with β adjustable from 0.0 to 2.4% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 (replaceable; included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 100 hours of continuous use, auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98129 is supplied with HI73127 pH electrode and HI73128 electrode removal tool, batteries (4 x 1.5V) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98129\" target=\"_blank\" rel=\"noopener\"\u003eCombo pH\/Conductivity\/TDS Tester (Low Range) - HI98129\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871262245233,"sku":"HI98129","price":19524.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98129-ppm_1.jpg?v=1792645989"},{"product_id":"multiparameter-benchtop-photometer-and-ph-meter-hi83300","title":"Multiparameter Benchtop Photometer and pH meter - HI83300-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eFrom aluminum to zinc, the HI83300 benchtop photometer measures 37 different key water quality parameters using 60 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\n\u003cp\u003eThe HI83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eBacklit 128 x 64 Pixel Graphic LCD Display\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit graphic display allows for easy viewing in low light conditions\u003c\/li\u003e\n\u003cli\u003eThe 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement is taken after the countdown timer expires.\u003c\/li\u003e\n\u003cli\u003eCountdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAbsorbance mode\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHanna's exclusive CAL Check cuvettes for validation of light source and detector\u003c\/li\u003e\n\u003cli\u003eAllows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUnits of Measure\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAppropriate unit of measure along with chemical form is displayed along with reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eResult Conversion\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAutomatically convert readings to other chemical forms with the touch of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCuvette Cover\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAids in preventing stray light from affecting measurements\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eDigital pH Electrode Input\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH and temperature with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eSpace saving having a pH meter and photometer built into one meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button\u003c\/li\u003e\n\u003cli\u003eSample ID and User ID information can be added to a logged reading using alphanumeric keypad\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port\u003c\/li\u003e\n\u003cli\u003eData is exported as a .CSV file for use with common spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBattery Status Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eIndicates the amount of battery life left\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eError Messages\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePhotometric error messages include no cap, high zero, and standard too low\u003c\/li\u003e\n\u003cli\u003epH calibration messages include clean electrode, check buffer and check probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/method-selection.png\" alt=\"method selection\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMethod Selection\u003c\/h4\u003e\n\u003cp\u003eUsers can easily select any one of the 60 measurement methods via the dedicated METHOD button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/data-logging.png\" alt=\"data logging\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eData Logging\u003c\/h4\u003e\n\u003cp\u003eUp to 1000 measurement readings can be logged with user and sample ID and recalled for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-measurement-mode.png\" alt=\"ph measurement mode\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003epH Measurement Mode\u003c\/h4\u003e\n\u003cp\u003eSelecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdvanced Optical System\u003c\/h4\u003e\n\u003cp\u003eHI83300 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/OpticalSystem.jpg\" alt=\"photometer multiparameter optical\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHigh Efficiency LED Light Source\u003c\/h4\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch4\u003eHigh Quality Narrow Band Interference Filters\u003c\/h4\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (±1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch4\u003eReference Detector for a Stable Light Source\u003c\/h4\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch4\u003eLarge Cuvette Size\u003c\/h4\u003e\n\u003cp\u003eThe sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch4\u003eFocusing Lens for Greater Light Yield\u003c\/h4\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI83300-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMultiparameter Benchtop Photometer and pH meter - HI83300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH\npH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH\npH electrode: 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH\npH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 ℃; 23.0 to 212.0 °F); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 4.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.003Abs @ 1.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\nSeawater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.00 mg\/L (as Al\u003csup\u003e3+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the aluminon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 3.00 mg\/L (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\nMedium Range: 0.00 to 10.00 mg\/L (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\nHigh Range: 0.0 to 100.0 mg\/L (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading\nMedium Range: ±0.05 mg\/L ±5% of reading\nHigh range: ±0.5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.50 mg\/L (as SDBS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 5540C, Anionic Surfactants as MBAS.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 8.00 mg\/L (as Br\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 400 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e)\nSeawater: 200 to 600 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater: ±10 mg\/L ±5% of reading\nSeawater: ±6% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater: Adaptation of the Oxalate method\nSeawater: Adaptation of the Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L (as Cl⁻)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±6% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Chlorophenol Red method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\nUltra Low Range: 0.000 to 0.500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\nUltra Low Range: 0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\nUltra Low Range: ±0.020 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\nUltra Low Range: 0.000 to 0.500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\nUltra High Range: 0 to 500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\nUltra Low Range: 0.001 mg\/L\nUltra High Range:1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\nUltra Low Range: ±0.020 mg\/L ±3% of reading\nUltra High Range: ±3 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\nFree Chlorine (ULR) \u0026amp; Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-Cl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Cr\u003csup\u003e6+\u003c\/sup\u003e)\nHigh Range: 0 to 1000 µg\/L (as Cr\u003csup\u003e6+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±1 µg\/L ±4% of reading\nHigh Range: ±5 µg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 PCU (Platinum Cobalt Units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Resolution\u003c\/td\u003e\n\u003ctd\u003e1 PCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 PCU ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Colorimetric Platinum Cobalt method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\nHigh range: 0.00 to 5.00 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading\nHigh Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±15% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as F\u003csup\u003e-\u003c\/sup\u003e)\nHigh range: 0.0 to 20.0 mg\/L (as F\u003csup\u003e-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\nHigh Range: ±0.5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 250 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\nMedium Range: 200 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\nHigh Range: 400 to 750 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±5 mg\/L ±4% of reading\nMedium Range: ±7 mg\/L ±3% of reading\nHigh Range: ±10 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA recommended method 130.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, EDTA Colorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Range\u003c\/td\u003e\n\u003ctd\u003e0 to 400 µg\/L (as N\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±4% of full scale reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 12.5 mg\/L (as I\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.600 mg\/L (as Fe)\nHigh Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±8% of reading\nHigh Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the TPTZ Method\nAdaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as Mg\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Mn)\nHigh Range: 0.0 to 20.0 (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±10 µg\/L ±3% of reading\nHigh Range: ±0.2 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN Method\nHigh Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo\u003csup\u003e6+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.000 mg\/L (as Ni)\nHigh Range: 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow range: ±0.010 mg\/L ±7% of reading\nHigh Range: ±0.07 g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN method\nHigh Range: Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0 to 600 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N)\nHigh Range: 0 to 150 mg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e)\nSeawater Ultra Low Range: 0 to 200 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 1 µg\/L; 1 mg\/L\nSeawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±20 µg\/L ±4% of reading\nHigh Range: ±4 mg\/L ±4% of reading\nSeawater\n±10 µg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA Diazotization method 354.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1000 µg\/L (as DEHA)\n0.00 to 1.50 mg\/L (as Carbohydrazide)\n0.00 to 2.50 mg\/L (as Hydroquinone)\n0.00 to 4.50 mg\/L (as ISO-ascorbic acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L (DEHA); 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 µg\/L ±5% of reading (DEHA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the iron reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0.00 to 2.50 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\nHigh range: 0.0 to 30.0 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\nSeawater Ultra Low Range: 0 to 200 µg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0.01 mg\/L; 0.1 mg\/L\nSeawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±0.04 mg\/L ±4% of reading\nHigh Range: ±1 mg\/L ±4% of reading\nSeawater Ultra Low Range: ±5 µg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: Adaptation of the Ascorbic Acid method\nFreshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L (as K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3.0 mg\/L ±7% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Turbidimetric Tetraphenylborate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e)\nHigh Range: 0 to 200 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\nHigh Range: ±1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method\nHigh Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as SO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Method\u003c\/td\u003e\n\u003ctd\u003eTurbidimetric - Sulfate is precipitated with barium chloride crystals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 5 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003edigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e128 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003ecalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003elog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery \/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0 ℃ (32 to 122.0 °F); 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97 mm (8.1 x 7.0 x 3.8”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI83300 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI83300-01\" target=\"_blank\" rel=\"noopener\"\u003eMultiparameter Benchtop Photometer and pH meter\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871272108401,"sku":"HI83300-02","price":164963.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83300-upper-angle-cover-closed_1.jpg?v=1792646009"},{"product_id":"advanced-ph-orp-benchtop-meter-hi6221-02","title":"Advanced pH\/ORP Benchtop Meter- HI6221-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eLaboratory\u003c\/h2\u003e\n\u003cp\u003eMeasure pH\/mV (pH) or mV\/Rel. mV (ORP) with Temperature\u003c\/p\u003e\n\u003cp\u003eHI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH \/ ORP measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the benchtop meter is delivered with Hanna Instruments HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe.\u003c\/p\u003e\n\u003cp\u003eHI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction reference and HT glass design allow the HI1131B to be used in a wide variety of applications including samples with metals and elevated temperatures. Probe connection to the unit is secured through a galvanically isolated BNC connection. HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221_front-rear.png\" alt=\"front back\" width=\"1250\" height=\"691\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThis system responds to a complex range of measurement and monitoring requirements, providing accuracy, reproducibility, and reliability. HI6221 is supplied with an electrode holder that has a flexible arm. The holder can be mounted quickly and provides secure support for electrodes while taking measurements in sample containers.\u003c\/p\u003e\n\u003ch4\u003eUser interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003cli\u003eThe user can select between five different views:\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH\/mV (pH) or mV\/Rel.mV (ORP) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor and system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic (using temperature probe) or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for pH\/ORP measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e5-point pH calibration with automatic recognition for standard buffers (Hanna and NIST buffers)\u003c\/li\u003e\n\u003cli\u003eChoice of standard or custom buffers for calibration\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLogging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnectivity features \u0026amp; services\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection\u003c\/li\u003e\n\u003cli\u003eUSB type A for USB stick, keyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHelp section for meter guidance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eVideo support presentation of main functionalities\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eCustomize calibration options such as Last Calibration, Automatic, semi-automtic or manual calibration, First Calibration Point, daily or periodic Calibration Reminder, and buffer Groups.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_08_Image_0007.jpg\" alt=\"\" width=\"460\" height=\"276\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_02_Image_0001.png\" alt=\"\" width=\"450\" height=\"450\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eCapacitive touch screen with multi-touch support\u003c\/h2\u003e\n\u003cp\u003eThe benchtop unit has a 7-inch color display with 800 x 480p resolution. The capacitive, multi-touch screen supports video playback and data plotting.\u003c\/p\u003e\n\u003ch2\u003eSystem Menu key\u003c\/h2\u003e\n\u003cp\u003eThis key will enter the system menu where User accounts, System Settings, and Logging can be configured. The Help menu is also accessed on the system menu screen.\u003c\/p\u003e\n\u003ch2\u003eMeasurement setup menu\u003c\/h2\u003e\n\u003cp\u003eOpens sensor setup parameters.\u003c\/p\u003e\n\u003ch2\u003eDirect\/Autohold readings\u003c\/h2\u003e\n\u003cp\u003eWhen Direct\/Autohold is selected, measurement reading is held on display when measurement stability is reached. This option removes the subjective nature of stability as a measurement that has not reached equilibrium will not be used.\u003c\/p\u003e\n\u003cp\u003eWhen not selected, sample measurements are displayed continuously.\u003c\/p\u003e\n\u003ch4\u003eHI6221 is supplied with:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHI1131B pH electrode; HI7662-TW temperature probe\u003c\/li\u003e\n\u003cli\u003epH calibration starter kit consisting of:\u003cul\u003e\n\u003cli\u003epH 4.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 7.01 buffer solution sachet (4 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 10.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHI700601 electrode cleaning solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eHI7082 3.5M KCl electrolyte solution (30 mL)\u003c\/li\u003e\n\u003cli\u003eHI764060 electrode holder\u003c\/li\u003e\n\u003cli\u003eCapillary pipette\u003c\/li\u003e\n\u003cli\u003e24 VDC power adapter\u003c\/li\u003e\n\u003cli\u003eUSB-C to USB-A cable\u003c\/li\u003e\n\u003cli\u003eQuick reference guide with instrument quality certificate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last signiﬁcant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last signiﬁcant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV oﬀset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Calibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003epH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom buﬀers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration 1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOﬀset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDaily: 0 m in. to 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003ePeriodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect; Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Isopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (pH, mV, Rel.mV, Abs.mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eTemperature, Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eLast calibration date, electrode oﬀset, average slope, and electrode condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003epH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle \/ Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003eUsers Up to 9 users and adm in. account (default):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP \/ Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (2.65 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6221-02\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871319884145,"sku":"HI6221-02","price":122546.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221-head-on-700x700-cd07ed0c-fd8c-42df-a0a8-112410be6851_4_2.jpg?v=1792646147"},{"product_id":"advanced-conductivity-benchtop-meter-hi6321","title":"Advanced Conductivity Benchtop Meter - HI6321-02","description":"\u003cp\u003eHI6321 is a streamlined Conductivity\/Resistivity\/TDS\/Salinity\/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity\/ resistivity\/TDS\/salinity probe.\u003c\/p\u003e\n\u003cp\u003eRecommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures.\u003c\/li\u003e\n\u003cli\u003eStandard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for \u0026gt;1Mohm.cm resistivity measurements.\u003c\/li\u003e\n\u003cli\u003eNatural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe result is reliable electrolytic conductivity (EC), TDS (Total Dissolved Solids), resistivity, or Seawater Salinity in percent, psu, or ppt units.\u003c\/p\u003e\n\u003cp\u003eTDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement.\u003c\/p\u003e\n\u003cp\u003eSal psu: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 ℃ and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g\/Kg water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 ℃.\u003c\/p\u003e\n\u003cp\u003eSal ppt: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g\/L and covers 10 to 31 ℃ temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 ℃ and an approximate salinity value of 35 in seawater.\u003c\/p\u003e\n\u003cp\u003eSal %: in this scale 100% salinity is equivalent to roughly 10% solids.\u003c\/p\u003e\n\u003ch2\u003eUser interface\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThe user can select between five different views:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMeasurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure µS\/cm, mS\/cm (Conductivity); ω·cm, kω·cm, Mω·cm (Resistivity); ppm, ppt (TDS); ppt, PSU,\n% (Salinity) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor\nand system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for conductivity measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCalibration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStandard single point salinity calibration in 100% salinity standard, with the reading salinity scale set to %\u003c\/li\u003e\n\u003cli\u003eStandard single or multiple conductivity calibration with standards\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogging\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConnectivity features \u0026amp; services\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection o USB type A for USB stick,\nkeyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 µS\/cm; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 µS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±1 Ω·cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water 0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration points\u003c\/td\u003e\n\u003ctd\u003eAuto standard recognition \/ User standard, Single Point \/ Multi Point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Standard solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 µS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling\u003c\/td\u003e\n\u003ctd\u003erate 1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information Last calibration date, oﬀset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (26.5 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6321\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322734961,"sku":"HI6321-02","price":148128.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6321-right-facing-700x700-d4924805-c4b9-4224-b973-d8a72a57f915.jpg?v=1792646150"},{"product_id":"multiparameter-portable-ph-ec-do-waterproof-meter-hi98199","title":"Multiparameter Portable pH\/EC\/DO Waterproof Meter - HI98199","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98199_with-boot-HI829113_angle-pH.jpg\" alt=\"HI98199\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSuperior Durability\u003c\/h5\u003e\n\u003cp\u003eAn IP67-rated, waterproof meter means that this meter is built to withstand immersion in 1m of water for up to 30 minutes. The meter has rubber gaskets sealing the battery compartment and connectors in epoxy to prevent any water from entering and damaging the internal electronics from water. With an ergonomic design and waterproofing the HI98199 will fit well in your hand and provides years of use.\u003c\/p\u003e\n\u003cp\u003eNote: The meter is displayed with an optional shockproof rubber boot for additional protection.\u003c\/p\u003e\n\u003ch5\u003eDot Matrix Display\u003c\/h5\u003e\n\u003cp\u003eThe large dot matrix display provides for an intuitive user interface in which the user is guided through any setup configuration or calibration. A dedicated help key provides for contextual help that is related to the screen being viewed at the time. The dot matrix display is viewable under bright sunlight and has a backlight for when viewing under poor lighting conditions.\u003c\/p\u003e\n\u003ch5\u003eAlphanumeric Keypad\u003c\/h5\u003e\n\u003cp\u003eThe low profile vulcanized rubber keypad along with virtual keys provide for a quick entry of password, user ID and sample site. The configuration of the meter can be password protected to prevent any unwanted changes. The user and sample ID are stored with any logged readings and can be transferred to a PC for analysis or long term record keeping.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI827113_HI763093_HI764103_HI98199_Group_3.jpg\" alt=\"Digital probes for HI98199\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eDigital Probes\u003c\/h5\u003e\n\u003cp\u003eHI98199 uses highly advance digital electrodes featuring a built-in microprocessor that performs the measurements. When these probes are connected to the meter they are automatically detected and the meter is updated to display the appropriate parameter. These digital electrodes also feature a quick connect DIN connector that provides a secure waterproof connection.\u003c\/p\u003e\n\u003ch5\u003eFlexibility\u003c\/h5\u003e\n\u003cp\u003eHI98199 is supplied with a pH\/temperature probe. The meter can always be upgraded to measure dissolved oxygen or conductivity by purchasing the compatible probe.\u003c\/p\u003e\n\u003ch5\u003eTraceability\u003c\/h5\u003e\n\u003cp\u003eThe calibration information for a connected probe can be viewed at anytime using the dedicated Good Laboratory Practice (GLP) button on the meter. The calibration information includes the date, time, calibration points and probe characteristic.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98199_Connection_angle.jpg\" alt=\"HI98199 USB\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eQuick Connect Digital Probe Connection with Auto-Sensor Recognition\u003c\/h5\u003e\n\u003cp\u003eThe Quick Connect DIN connector is designed for quick and secure waterproof connection. The meter will automatically recognizes the probe attached and uploads stored calibration data. Each probe then transmits readings digitally to the meter overcoming challenges faced with standard analog probes.\u003c\/p\u003e\n\u003ch5\u003eUSB-C Port for Data Transfer\u003c\/h5\u003e\n\u003cp\u003eThe USB-C port is used for transferring logged data to a PC using Windows compatible software. The HI98199 can log up to 45, 000 samples either by interval logging at a set time period or by log on demand of an individual reading.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Pressure Transducer\u003c\/h5\u003e\n\u003cp\u003eThe HI98199 has a built in pressure transducer for the measurement of barometric pressure. The pressure measurement can be viewed with any probe connected but the measurement is used when measuring dissolved oxygen for automatic atmospheric pressure compensation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMultiparameter Portable pH\/EC\/DO Waterproof Meter - HI98199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading or ±2 µS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic single-point, with six standard solutions (84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 200.0 ppt (g\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L) whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e25 °C or 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Type\u003c\/td\u003e\n\u003ctd\u003efour ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Multi-range Measurement Modes\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω cm; 0.1 kΩ cm; 0.0001 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003egalvanic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater\n300.0 to 500.0%: ±3% of reading\n0.00 to 30.00 ppm (mg\/L) ±1.5% of reading or ±0.10 ppm (mg\/L), whichever is greater\n30.00 ppm (mg\/L) to 50.00 ppm (mg\/L): ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two points at 0, 100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00 °C; 23.00 to 131.00 °F; 268.15 to 328.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C; 0.01 °F; 0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15 °C; ±0.27 °F; ±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 55 °C (23 to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003econtinuous logging or log-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e45000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Interval\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003evia USB-C with Hanna software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eNot used (disabled), 5, 10, 15, 20, 30, 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Timeout Reminder\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003edot matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 400 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98199 is supplied with the HI829113 pH digital probe with 4m (13’) cable, pH calibration solution sachets, PC software, micro USB cable, batteries, quality certificate, and instruction manual in a rugged carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98199\" target=\"_blank\" rel=\"noopener\"\u003eMultiparameter Portable pH\/EC\/DO Waterproof Meter - HI98199\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322767729,"sku":"HI98199","price":101000.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98199_with_hi829113_1.jpg?v=1792646150"},{"product_id":"in-line-conductivity-probe-with-pt100-sensor-3m-cable-hi7639-3m-9-84","title":"In-line Conductivity Probe with Pt100 Sensor,  3m Cable - HI7639-3m (9.84')","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Conductivity-Probes-Diagram-1_00000002.jpg\" alt=\"HI7639 conductivity probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e\u003cstrong\u003eAdvantage of Four Ring Conductivity Probe\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThree types of conductivity probes are manufactured by Hanna, amperometric (2 Ring), potentionmetric (Four Ring) and Inductive (Electrodeless or Toroidal conductivity probe).\u003c\/p\u003e\n\u003cp\u003eFour electrode conductivity (four-ring conductivity) utilizes a potentionmetric approach to make the measurement; an alternating current is applied to the outer two \"drive\"electrodes to induce a current in the solution. The voltage is measured between the inner pair of electrodes in solution. The voltage is proportional the conductivity This technology extends the linear range of measurement over three decades. Electrodes are made of graphite, stainless steel or Platinum. Polarization effects are reduced.\u003c\/p\u003e\n\u003cp\u003eThe universally acclaimed four-ring method provides an exceptionally stable measurement over a wider range.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThese probes do not suffer polarization\u003c\/li\u003e\n\u003cli\u003eNo need of frequent calibration or cell changes.\u003c\/li\u003e\n\u003cli\u003eMore Stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHI7639 Conductivity Electrode FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch4\u003eIn-line conductivity probe\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eSuitable for direct immersion in pipes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eBuilt-in Pt100 temperature sensor\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvide accurate and effective temperature compensation.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eColor coded wires\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003e3m cable incorporating color coded wires for easy connection to transmitters .\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003ePlatinum sensor\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvides the best response over a wide range of applications.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003ePEI body\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003ePEI bodied electrodes are rugged and suitable for noncritical applications that require a very good combination of chemical, mechanical, and thermal resistance.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eFour-ring method\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvides an exceptionally stable measurement over a wider range. These probes do not suffer polarization, nor do they need frequent calibration or cell changes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eIn-line Conductivity Probe with Pt100 Sensor, 3m Cable - HI7639-3m (9.84')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7639\" target=\"_blank\" rel=\"noopener\"\u003eIn-line Conductivity Probe with Pt100 Sensor, 3m Cable - HI7639-3m (9.84')\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322800497,"sku":"HI7639","price":53735.4,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ec-tds-probe-with-pt100-sensor.jpg?v=1792646150"},{"product_id":"waterproof-phep5-ph-temperature-tester-hi98128","title":"Waterproof pHep®5 pH\/Temperature Tester - HI98128","description":"\u003cp\u003eThe pHep®5 is a waterproof pH tester with a 0.01 pH resolution and an accuracy of ±0.5 pH. The one, two, or three-point calibration is automatic to two selectable buffer sets (4.01, 7.01 and 10.01 or 4.01, 6.86, and 9.18). The pHep®5 also features a replaceable electrode with a stainless steel round connector. The HI73127 replacement pH electrode also features an extractable cloth that is used to renew the junction by extracting ⅛” of the cloth junction to expose a new portion. Any clogging that was present is cleared and the response time will be back to normal, extending the life of the pH electrode.\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cp\u003eWaterproof casing designed to float if dropped in water\u003c\/p\u003e\n\u003cp\u003eExpanded pH Range from -2.0 to 16.0 pH\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation, displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eStability indicator confirms the reading has stabilized\u003c\/p\u003e\n\u003cp\u003eHOLD button for easier measurement recording\u003c\/p\u003e\n\u003cp\u003eBattery Error Prevention System (BEPS)\u003c\/p\u003e\n\u003cp\u003eAuto-off to preserve battery life\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWaterproof pHep\u003csup\u003e®\u003c\/sup\u003e5 pH\/Temperature Tester - HI98128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one, two, or three points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 replaceable pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 300 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98128 (pHep\u003csup\u003e®\u003c\/sup\u003e5) is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98128\" target=\"_blank\" rel=\"noopener\"\u003eWaterproof pHep\u003csup\u003e®\u003c\/sup\u003e5 pH\/Temperature Tester - HI98128\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322898801,"sku":"HI98128","price":13266.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98128.jpg?v=1792646152"},{"product_id":"advanced-dissolved-oxygen-benchtop-meter-with-optical-do-probe-opdo-hi6421","title":"Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®) - HI6421-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHI6421 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated module designed for fresh and saltwater measurements of dissolved oxygen.\u003c\/p\u003e\n\u003cp\u003eHI6421 includes Hanna's HI7641133 optical dissolved oxygen probe (opdo®) that is based on the principle of fluorescence quenching. An immobilized Pt-based luminophore is excited by the light of a blue LED and emits a red light. As oxygen interacts with the luminophore it reduces the intensity and lifetime of the luminescence. The lifetime of the luminescence is measured by a photodetector and is used to calculate the dissolved oxygen concentration.\u003c\/p\u003e\n\u003cp\u003eThe probe is fitted with easy to use Smart Caps (HI764113-1) which lock in place and contain pre-loaded calibration coefficients that are automatically transmitted to the probe. The Smart Cap features an immobilized O₂ sensitive luminophore with rugged insoluble black oxygen permeable protective layer. Over time, the sensor’s optical components can age but are compensated for by using the reference signal to compensate the measuring path. As a result, the sensor provides accurate DO measurements over long periods of time without the need for frequent calibration. Concentration measured. Additional features include built-in methods and calculations for the measurement of BOD (Biological Oxygen Demand), OUR (Oxygen Uptake Rate), and SOUR (Specific Oxygen Update Rate). Pressure compensation is done automatically (built-in barometer) or users have the option to manually enter required value. Pressure is displayed in user-configurable units: mmHg, mbar, kPa, inHg, psi, atm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6321_1p0_1222_WEB.jpg\" alt=\"systemUI\" width=\"700\" height=\"537\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch4\u003eUser interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThe user can select between five different views:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure %Sat, mg\/L, ppm (DO); mg\/L, ppm (BOD); mg\/L (OUR); ppm, mg\/L (SOUR)\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the\nsensor and system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/auto-hold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOne or two points calibration at 0% and\/or 100% saturation\u003c\/li\u003e\n\u003cli\u003eSingle point manual calibration in mg\/L or % saturation using a reference method\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLogging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, auto-hold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and auto-hold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnectivity features \u0026amp; services\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data ta USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection\u003c\/li\u003e\n\u003cli\u003eUSB type A for USB stick, keyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHelp section for meter guidance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eVideo support presentation of main functionalities\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information:\u003c\/h2\u003e\n\u003cp\u003eHI6421 is supplied with HI7641133 optical dissolved oxygen probe (opdo®); HI764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate.\u003c\/p\u003e\n\u003ch2\u003eAccessories:\u003c\/h2\u003e\n\u003cp\u003eHI7641133 optical dissolved oxygen probe (opdo®)\u003cbr\u003e\nHI764113-1 Smart cap with O-ring\u003cbr\u003e\nHI764113-2 Calibration\/storage vessel\u003cbr\u003e\nHI764113-3 Stainless steel protective shield\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003e \u003c\/p\u003e\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo\u003csup\u003e®\u003c\/sup\u003e) - HI6421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO meter Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Meter Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 500.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Accuracy\u003c\/td\u003e\n\u003ctd\u003efrom 0.00 to 20.00 mg\/L (ppm) 1.5 % of reading or ± 0.01 mg\/L (ppm), whichever is greater from 20.00 to 50.00 mg\/L (ppm) ±5 % of reading from 0.0 to 200.0 % saturation ± 1.5 % of reading or ± 0.1 %, whichever is greater from 200.0 to 500.0 % saturation ±5 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Range\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa; 17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least signiﬁcant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Points\u003c\/td\u003e\n\u003ctd\u003eOne or two points automatic calibration at 100% (8.26 mg\/L) and 0% (0 mg\/L). Single point manual using a value entered by the user in % saturation or mg\/L.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Standards\u003c\/td\u003e\n\u003ctd\u003e0 and 100% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic from 0 to 70 PSU (manually set) 0.0 to 70.0 % \/ 0.0 to 45.0 g\/L \/ 0.0 to 42.0 psu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Isopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (DO, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Simple\u003c\/td\u003e\n\u003ctd\u003eGLP Basic view information Last calibration date, oﬀset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Full\u003c\/td\u003e\n\u003ctd\u003eGLP Simple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds \/ 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP \/ Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg (26.5 lbs.)1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6421\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo\u003csup\u003e®\u003c\/sup\u003e) - HI6421\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871326273905,"sku":"HI6421-02","price":215460.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6421.jpg?v=1792646160"},{"product_id":"free-chlorine-checker-hc-hi701","title":"Free Chlorine Checker® HC - HI701","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI701 Checker®HC (Handheld Colorimeter) is a simple, accurate and cost effective way to measure free chlorine. Free chlorine is the active form of chlorine used for disinfection of drinking water, swimming pools and spas, and vegetable rinse water. Free chlorine in water is also harmful to a reverse osmosis membrane and needs to be monitored for removal from source water prior to being used. Designed as a more accurate alternative to chemical test kits, the HI701 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFor use with freshwater samples\u003c\/li\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Pools and Spas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of USEPA method 330.5. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI701 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, free chlorine reagent starter kit (reagents for 6 tests), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI701\" target=\"_blank\" rel=\"noopener\"\u003eFree Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI701\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871346229617,"sku":"HI701","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi701-checkerhc-front.jpg?v=1792646208"},{"product_id":"phosphorus-high-range-checkerhc-hi706","title":"Phosphorus High-Range Checker®HC - HI706","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI706 Checker®HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure phosphorus. Common in natural systems, such as lakes, oceans, and soil, phosphorus is an essential element in plant growth. However, when present in large concentrations, phosphorus can cause excessive microorganism and algae growth, as well as corrosion to piping systems. Designed as a more accurate alternative to chemical test kits, the HI706 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Aquariums\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePhosphorus High-Range Checker\u003csup\u003e®\u003c\/sup\u003eHC - HI706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Heteropolymolybdenum Blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI706 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, phosphorus HR reagent starter kit for 20 tests (1 bottle of phosphorus reagent A, 20 packets of phosphorus HR reagent B), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI706\" target=\"_blank\" rel=\"noopener\"\u003ePhosphorus High-Range Checker\u003csup\u003e®\u003c\/sup\u003eHC - HI706\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871367364977,"sku":"HI706","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi706-checkerhc-front.jpg?v=1792646271"},{"product_id":"waterproof-portable-ph-temperature-meter-hi991001","title":"Waterproof Portable pH\/Temperature Meter - HI991001","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI991001 meter features a large multi level LCD screen which displays both pH and temperature readings simultaneously with 0.01 pH resolution and an accuracy of ±0.02 pH. The LCD screen also has indicators for calibration status and stability, as well as on-screen tutorial messages. The HI991001 has many advanced features that are found in more expensive portable instrumentation including automatic calibration, buffer recognition, and temperature compensation. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1296.jpg\" alt=\"HI1296D\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eHI12963 pH Electrode with Quick Connect DIN Connector\u003c\/h2\u003e\n\u003cp\u003eThe HI991001 is supplied with the pre-amplified titanium body pH\/temperature electrode. The titanium body is resistant to many aggressive chemicals including those used in plating and chemical manufacturing. The titanium body acts as a matching pin that, together with the built-in amplifier, will help reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include rectifiers, motors and ballasts.\u003c\/p\u003e\n\u003cp\u003eThe HI12963 pH electrode also features an extractable cloth junction. The extractable cloth junction of the HI12963 allows for the renewing of the junction. Simply extract ⅛\" of the junction by pulling on the junction will expose a new portion. Any clogging that was present will be cleared and the response time will be back to normal extending the life of the pH electrode.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTitanium body that is resistant to harsh chemicals\u003c\/li\u003e\n\u003cli\u003ePre-amplified and matching pin for resistance to electrical noise\u003c\/li\u003e\n\u003cli\u003eExtractable cloth junction to clear any clogging\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature sensor for automatic temperature compensated readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch5\u003eWaterproof\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDesigned to float if accidentally dropped in a tank\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eExpanded pH Range\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003epH range is from -2.00 to 16.00 pH\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Two-Point Calibration\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eOne or two-point calibration is automatic to two selectable buffer sets (4.01, 7.01 and 10.01 or NIST 4.01, 6.86, and 9.18).\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll readings are compensated for variations in temperature\u003c\/li\u003e\n\u003cli\u003eTemperature displayed in ℃ or ℉ along with pH reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHOLD button\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes reading on the display to allow recording of measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBEPS (Battery Error Prevention System)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBattery % level at startup\u003c\/h5\u003e\n\u003ch5\u003eLow Battery Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-Off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeter automatically shuts off after 8 minutes of non-use to maximize battery life\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI991001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWaterproof Portable pH\/Temperature Meter - HI991001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH; -2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH; 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH; ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic ‐5.0 to 105.0 °C\/23.0 to 221.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eprobe condition indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Sensor Check\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±825 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 80.0°C \/ 23.0 to 176.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (up to 60°C); ±1.0°C (outside) \/ ±1°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI12963 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: after 8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (3) AAA \/ approximately 1400 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e196 g (6.91 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI991001 is supplied with HI12963 pH probe with internal temperature sensor, HI70004 pH 4.01 buffer sachet (20 mL x1), HI70007 pH 7.01 buffer sachet (20 mL x1), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL beaker (1), calibration certificates for both meter and probe, batteries, instructions, and rugged thermoformed carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI991001\" target=\"_blank\" rel=\"noopener\"\u003eWaterproof Portable pH\/Temperature Meter - HI991001\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871368151409,"sku":"HI991001","price":57977.1,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi991001_c_manual.jpg?v=1792646279"},{"product_id":"nitrite-low-range-checker-hc-hi707","title":"Nitrite Low-Range Checker® HC-HI707","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI707 Checker® HC (Handheld Colorimeter) provides a simple,  accurate and cost effective way to measure nitrite. As an intermediate part of the nitrogen cycle,  nitrites are present in a variety of sources,  from drinking water to industrial water.  Due to the harmful effects to the environment and aquatic life,  nitrite levels must be closely monitored.  Designed as a more accurate alternative to chemical test kits,  the HI707 provides quick,  accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size,  big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality,  Environmental,  Education,  Aquaculture,  Boiling and Cooling Towers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrite Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC-HI707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 600 ppb NO₂-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±20 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003e adaptation of the EPA Diazotization method 354.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e LED @ 470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e silicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e (1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI707 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, nitrite LR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI707\"\u003eNitrite Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC-HI707\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871368380785,"sku":"HI707","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi707-checkerhc-front.jpg?v=1792646281"},{"product_id":"nitrite-high-range-checker-hc-hi708","title":"Nitrite High-Range Checker® HC - HI708","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI708 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure nitrite. As an intermediate part of the nitrogen cycle, nitrites are present in a variety of sources, from drinking water to industrial water. Due to the harmful effects to the environment and aquatic life, nitrite levels must be closely monitored. Designed as a more accurate alternative to chemical test kits, the HI708 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Aquaculture, Boiling and Cooling Towers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI708\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eNitrite High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI708\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Ferrous Sulfate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI708 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, nitrite HR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI708\" target=\"_blank\" rel=\"noopener\"\u003eNitrite High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI708\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871384928625,"sku":"HI708","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi708-checkerhc-front.jpg?v=1792646310"},{"product_id":"manganese-high-range-checker-hc-hi709","title":"Manganese High-Range Checker® HC - HI709","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI709 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure manganese. Designed as a more accurate alternative to chemical test kits, the HI709 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water quality, Environmental, Plating, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eManganese High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading ± 0.2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method. The reaction between manganese and reagents causes a pink tint in the sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI709 Checker\u003csup\u003e®\u003c\/sup\u003eHC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI709\" target=\"_blank\" rel=\"noopener\"\u003eManganese High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI709\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871387615601,"sku":"HI709","price":7014.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi709-checkerhc-front.jpg?v=1792646316"},{"product_id":"total-chlorine-checker-hc-hi711","title":"Total Chlorine Checker® HC - HI711","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI711 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure total chlorine. Chlorine is a popular disinfectant used in municipal water, fruits and vegetables, as well as equipment in the food and beverage industry. Though beneficial in destroying pathogens, levels greater than 4 parts per million (ppm) is harmful to humans and therefore, must be monitored. Designed as a more accurate alternative to chemical test kits, the HI711 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Education, Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of USEPA method 330.5, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI711 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, total chlorine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI711\" target=\"_blank\" rel=\"noopener\"\u003eTotal Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI711\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871388270961,"sku":"HI711","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi711-checkerhc-front.jpg?v=1792646324"},{"product_id":"phosphate-low-range-checker-hc-hi713","title":"Phosphate Low-Range Checker® HC - HI713","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI713 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure phosphate. Phosphate is a common food additive that enhances flavor and acts as a buffering agent. Important for growth and development of plant roots, phosphate is also present in fertilizers. However, high concentrations of phosphates are detrimental to the environment; for this reason, it is closely monitored in natural and municipal waters. Designed as a more accurate alternative to chemical test kits, the HI713 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Aquaculture, Education, Agriculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePhosphate Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, Ascorbic-Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter three minutes of non-use and two minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI713 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, phosphate LR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI713\" target=\"_blank\" rel=\"noopener\"\u003ePhosphate Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI713\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871388533105,"sku":"HI713","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi713-checkerhc-front.jpg?v=1792646328"},{"product_id":"bromine-checker-hc-hi716","title":"Bromine Checker® HC - HI716","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI716 Checker® HC (Handheld Colorimeter) provides a simple,  accurate and cost effective way to measure bromine.  Introduced as an alternative to chlorine,  the use of bromine as a sanitizer is increasing in use in many countries.  Bromine is less volatile and has more effective results above a pH of 7.4,  but is an overall slower acting disinfectant. Designed as a more accurate alternative to chemical test kits,  the HI716 provides quick,  accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size,  big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality,  Industrial,  Municipal Water,  Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Bromine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 8.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.08 ppm ±5% of reading @ 25 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003e adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e LED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e silicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e (1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 86.0mm x 61mm x 37.5mm (3.4 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI716 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, bromine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI716\"\u003eBromine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI716\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390466417,"sku":"HI716","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi716-checkerhc-front.jpg?v=1792646334"},{"product_id":"phosphate-high-range-checker-hc-hi717","title":"Phosphate High-Range Checker® HC - HI717","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI717 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure phosphate. Phosphate is a common food additive that enhances flavor and acts as a buffering agent. Important for growth and development of plant roots, phosphate is also present in fertilizers. However, high concentrations of phosphates are detrimental to the environment; for this reason, it is closely monitored in both natural and municipal water systems. Designed as a more accurate alternative to chemical test kits, the HI717 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Aquaculture, Education, Industrial, Agriculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePhosphate High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Heteropolymolybdenum Blue method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI717 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, phosphate HR reagent starter kit for 20 tests (1 bottle of phosphate HR reagent A, 20 packets of phosphate HR reagent B), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI717\" target=\"_blank\" rel=\"noopener\"\u003ePhosphate High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI717\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390597489,"sku":"HI717","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi717-checkerhc-front.jpg?v=1792646336"},{"product_id":"iodine-checker-hc-hi718","title":"Iodine Checker® HC - HI718","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI718 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure iodine. Introduced as an alternative to chlorine, iodine as a sanitizer decreases eye irritation in pools and saps and provides a more stable level of disinfection in adverse conditions. However, due to its toxic and corrosive properties, iodine is strictly monitored. Designed as a more accurate alternative to chemical test kits, the HI718 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Education, Industrial, Agriculture, Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI718\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eIodine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI718\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 12.5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI718 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, iodine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI718\" target=\"_blank\" rel=\"noopener\"\u003eIodine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI718\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390761329,"sku":"HI718","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi718-checkerhc-front.jpg?v=1792646338"},{"product_id":"calcium-hardness-checker-hc","title":"Calcium Hardness Checker® HC - HI720","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI720 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure calcium. Designed as a more accurate alternative to chemical test kits, the HI720 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water quality, Environmental, Plating, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCalcium Hardness Checker\u003csup\u003e®\u003c\/sup\u003e HC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading ± 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method. The reaction between calcium and reagents causes a reddish-violet tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI720 Checker\u003csup\u003e®\u003c\/sup\u003eHC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual. *CALcium Hardness Checker\u003csup\u003e®\u003c\/sup\u003e HC\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391220081,"sku":"HI720","price":7014.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi720-checkerhc-front.jpg?v=1792646343"},{"product_id":"iron-checker-hc-hi721","title":"Iron Checker® HC - HI721","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI721 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure iron. Naturally present in water in low concentrations, iron may affect the taste of water, as well as stain both laundry and household appliances. Also an indicator of corrosion, iron is monitored in industrial plants and water cooling and heating systems. Designed as a more accurate alternative to chemical test kits, the HI721 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Education, Industrial, Municipal Water, Aquarium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eIron Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter three minutes of non-use and two minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI721 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, iron reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI721\" target=\"_blank\" rel=\"noopener\"\u003eIron Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI721\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391351153,"sku":"HI721","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi721-checkerhc-front.jpg?v=1792646344"},{"product_id":"nickel-hr-checker-hc-hi726","title":"Nickel HR Checker® HC - HI726","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI726 Checker® HC (Handheld Colorimeter) provides a simple,  accurate and cost-effective way to measure nickel. Commonly used by both the electroplating and battery industries,  nickel is actively monitored in wastewater due to damage it can cause to plants and aquatic life. Designed as a more accurate alternative to chemical test kits,  the HI726 provides quick,  accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size,  big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality,  Environmental,  Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI726\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nickel High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI726\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 7.00 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.10 g\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003e adaptation of the photometric method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e LED @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e silicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e (1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI726 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, Nickel HR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI726\"\u003eNickel High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI726\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391842673,"sku":"HI726","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi726-checkerhc-front_1.jpg?v=1792646353"},{"product_id":"color-of-water-checker-hc-hi727","title":"Color of Water Checker® HC - HI727","description":"\u003cp\u003eThe HI727 Checker®HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure the color of water. Used in drinking water and wastewater, the color of water may indicate the presence of undesirable and potentially harmful material, such as organic matter. Other harmless constituents of water such as tannins, iron and manganese, may also be present and impart color. The HI727 reports the color of water from 0-500 PCU (Platinum Cobalt Units).\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI727\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eColor of Water Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI727\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 PCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Resolution\u003c\/td\u003e\n\u003ctd\u003e5 PCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 PCU ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 21st edition, Colorimetric Platinum Cobalt method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI727 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI727\" target=\"_blank\" rel=\"noopener\"\u003eColor of Water Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI727\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871392498033,"sku":"HI727","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi727-checkerhc-front.jpg?v=1792646355"},{"product_id":"epa-compliant-benchtop-turbidity-meter-hi88703","title":"EPA Compliant Benchtop Turbidity Meter - HI88703-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI88703 Precision Turbidity Benchtop Meter is specially designed for water quality measurements, providing reliable and accurate readings, especially in the low turbidity range. The instrument is based on a state-of-the-art optical system which guarantees accurate results, assures long term stability, and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the tungsten lamp. The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance:\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eTwo Measurement Modes\u003c\/strong\u003e - The HI88703 features two options for turbidity measurement: ratio and non-ratio mode. Turbidity measurements can be made in the 0.00 to 4000 NTU (Nephelometric Turbidity Units) when using the ratio mode and in the 0.00 to 40.0 NTU range when non-ratio mode is used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eMultiple Turbidity Units of Measure\u003c\/strong\u003e - Turbidity can be read as Nephelometric Turbidity Units (NTU), European Brewing Convention units (EBC), or Nephelos units.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEPA Compliant\u003c\/strong\u003e - The HI88703 meets and exceeds the requirements of EPA and Standard Methods for turbidity measurements. When the meter is in EPA mode all turbidity readings are rounded accordingly to meet reporting requirements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e - The HI88703 has a powerful calibration function that compensates for lamp aging or changing. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two, three, four, or five-point turbidity calibration can be performed by using the supplied (\u0026lt;0.10, 15.0, 100, 750, and 2000 NTU) standards. Calibration points can be modified if user-prepared standards are used.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAMCO AEPA-1 Primary Turbidity Standard\u003c\/strong\u003e - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGLP Data\u003c\/strong\u003e - The HI88703 features complete GLP (Good Laboratory Practice) functions that allow traceability of the calibration conditions. Data includes calibration points, date, and time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e - Up to 200 measurements can be stored in the internal memory and recalled at any time.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Transfer\u003c\/strong\u003e - For further storage or analysis options, logged data can be downloaded to a Windows compatible PC using the USB port and the HI92000 software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTutorial Mode\u003c\/strong\u003e - The unique tutorial mode provides additional information to help the user during measurements. When enabled, the instrument displays explanations and a confirmation button when a preparation or other operation has to be performed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eContextual Help\u003c\/strong\u003e - Contextual help is always available through a dedicated HELP button. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.The help information displayed is relative to the setting\/option being viewed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBacklit Graphic LCD Display \u003c\/strong\u003e- A graphic LCD display provides an easy to understand, user-friendly interface. All messages are in plain text making them easy to read.\u003c\/p\u003e\n\u003cp\u003eTurbidity is one of the most important parameters used to determine the quality of drinking water. Once considered as a mostly aesthetic characteristic of drinking water, significant evidence exists that controlling turbidity is a competent safeguard against pathogens. In natural water, turbidity measurements are taken to gauge general water quality and its compatibility in applications involving aquatic organisms. The monitoring and treatment or wastewater was once solely based on the control of turbidity. Currently, the measurement of turbidity at the end of the wastewater treatment process is necessary to verify that the values are within regulatory standards.\u003c\/p\u003e\n\u003cp\u003eTurbidity of water is an optical property that causes light to be scattered and absorbed, rather than transmitted. The scattering of light that passes through a liquid is primarily caused by the suspended solids present. The higher the turbidity, the greater the amount of scattered light. Even a very pure liquid will scatter light to a certain degree, as no solution will have zero turbidity.\u003c\/p\u003e\n\u003cp\u003eDrinking water treatment plants that obtain water from surface water are required by the EPA to monitor and report the turbidity. Surface water sources include lakes and rivers. The requirements of the nephelometer and reporting measurements according to \u003ca href=\"https:\/\/www.epa.gov\/sites\/production\/files\/2015-08\/documents\/method_180-1_1993.pdf\" target=\"_blank\" rel=\"noopener\"\u003eEPA Method 180.1\u003c\/a\u003e are:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThe applicable range is 0-40 nephelometric turbidity units (NTU)\u003c\/li\u003e\n\u003cli\u003eLight source: Tungsten lamp operated at a color temperature between 2200-3000°K.\u003c\/li\u003e\n\u003cli\u003eDistance traversed by incident light and scattered light within the sample tube: Total not to exceed 10 cm.\u003c\/li\u003e\n\u003cli\u003eDetector: Centered at 90° to the incident light path and not to exceed ±30° from 90°. The detector, and filter system if used, shall have a spectral peak response between 400 nm and 600 nm\u003c\/li\u003e\n\u003cli\u003eThe sensitivity of the instrument should permit detection of a turbidity difference of 0.02 NTU or less in waters having turbidities less than 1 unit.\u003c\/li\u003e\n\u003cli\u003eReport results as follows:\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"160\"\u003e \u003ccol width=\"156\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNTU reading\u003c\/td\u003e\n\u003ctd\u003eRounded to nearest\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e0.0 - 1.0\u003c\/td\u003e\n\u003ctd\u003e0.05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1 - 10\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10 - 40\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e40 - 100\u003c\/td\u003e\n\u003ctd\u003e5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e100 - 400\u003c\/td\u003e\n\u003ctd\u003e10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e400 - 1000\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1000\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eThe HI88703 meets and exceeds the meter criteria specied by the EPA Method 180.1 and Standard Methods for the Examination of Water and Wastewater 2130 B.\u003c\/p\u003e\n\u003ch5\u003ePrincipal of Operation\u003c\/h5\u003e\n\u003cp\u003eThe light beam that passes through the sample is scattered in all directions. The intensity and pattern of the scattered light is affected by many variables, such as wavelength of the incident light, particle size and shape, refractive index, and color. The optical system of the HI88703 includes a tungsten filament lamp, a scattered light detector (90°) and a transmitted light detector (180°).\u003c\/p\u003e\n\u003cp\u003eIn the ratio turbidimeter range, the microprocessor of the instrument calculates the NTU value from the signals that reach the two detectors by using an effective algorithm that corrects and compensates for interferences of color. The optical system and measuring technique also compensate for fluctuations in lamp intensity, minimizing the need for frequent calibration.\u003c\/p\u003e\n\u003cp\u003eIn the non-ratio turbidimeter range, the NTU value is calculated from the signal on the scattered light detector (90°). This method offers a high linearity on the low range but is more sensitive to lamp intensity fluctuations. The lower detection limit of a turbidimeter is determined by stray light that is detected by the sensors but not caused by light scattering from suspended particles. The optical system of the HI88703 is designed to have very low stray light, providing highly accurate results for low turbidity samples.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-05-29_at_2.26.23_PM.png\" alt=\"Turbidity meter light path\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI88703-11.jpg\" alt=\"HI88703-11 turbidity standards\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe HI88703-11 AMCO AEPA-1 standards ensure that measurements are traceable to a primary reference materials. These standards are used for calibration and performance verification of the turbidity meter.\u003c\/p\u003e\n\u003ch5\u003eSupplied with Certificate of Analysis\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003cli\u003eStandard value @ 25 \u003csup\u003e°\u003c\/sup\u003eC\u003c\/li\u003e\n\u003cli\u003eReference meter NIST traceable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eProvided storage containers\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLight tight\u003c\/li\u003e\n\u003cli\u003eProtects from accidental breakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI88703-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eEPA Compliant Benchtop Turbidity Meter - HI88703\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd\u003eNon-Ratio mode: 0.00 to 9.99; 10.0 to 40.0 NTU; 0.0 to 99.9; 100 to 268 Nephelos; 0.00 to 9.80 EBC\nRatio mode: 0.00 to 9.99; 10.0 to 99.9; 100 to 4000 NTU; 0.0 to 99.9; 100 to 26800 Nephelos; 0.00 to 9.99; 10.0 to 99.9; 100 to 980 EBC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd\u003eNon-Ratio mode: 0.01; 0.1 NTU; 0.1; 1 Nephelos; 0.01 EBC\nRatio mode: 0.01; 0.1; 1 NTU; 0.1; 1 Nephelos; 0.01; 0.1, 1 EBC.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading plus 0.02 NTU (0.15 Nephelos; 0.01 EBC); ±5% of reading above 1000 NTU (6700 Nephelos; 245 EBC).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Repeatability\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or 0.02 NTU (0.15 Nephelos; 0.01 EBC) whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Stray Light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt; 0.02 NTU (0.15 Nephelos; 0.01 EBC)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Calibration\u003c\/td\u003e\n\u003ctd\u003etwo, three, four, or five-point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Measuring Method\u003c\/td\u003e\n\u003ctd\u003enephelometric method (90°) or ratio nephelometric method (90° \u0026amp; 180°), adaptation of the USEPA Method 180.1 and Standard Method 2130 B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Measuring Modes\u003c\/td\u003e\n\u003ctd\u003enormal, average, continuous\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Light Source\u003c\/td\u003e\n\u003ctd\u003etungsten filament lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e200 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e40 x 70 mm graphic LCD (64 x 128 pixels) with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e115\/130 VAC; 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e230 x 200 x 145 mm (9.0 x 7.9 x 5.7 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.5 kg (88 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI88703 is supplied with sample cuvettes (5) with caps, HI88703-11 calibration cuvettes for turbidity, silicone oil, cuvette wiping cloth, power cord, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI88703-01\" target=\"_blank\" rel=\"noopener\"\u003eEPA Compliant Benchtop Turbidity Meter - HI88703\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871393710449,"sku":"HI88703-02","price":294806.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi88703.jpg?v=1792646368"},{"product_id":"marine-phosphorus-ultra-low-range-checker-hc-hi736","title":"Marine Phosphorus Ultra Low-Range Checker® HC - HI736","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI736 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure phosphorus in marine systems including reef tanks. Phosphorus is an important parameter to measure in aquaculture and aquariums; levels that are too high can lead to extensive algae growth, depleted dissolved oxygen levels, and ultimately can be fatal to many types of fish and aquatic life. Designed as a more accurate alternative to chemical test kits, the HI736 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Aquariums, Environmental, Aquaculture, Water Quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Phosphorus Ultra Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI736\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, Ascorbic-Acid method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter three minutes of non-use and two minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0mm x 61mm x 37.5mm (3.4 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI736 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, phosphorus ULR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI736\" target=\"_blank\" rel=\"noopener\"\u003eMarine Phosphorus Ultra Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI736\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871395250545,"sku":"HI736","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi736-checkerhc-front.jpg?v=1792646382"},{"product_id":"iris-visible-spectrophotometer-hi801","title":"iris Visible Spectrophotometer - HI801-02","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/iris-rainbow.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSuperior design for superior results.\u003c\/h4\u003e\n\u003cp\u003eiris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.\u003c\/p\u003e\n\u003cp\u003eWith the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.\u003c\/p\u003e\n\u003ch4\u003eNo need for measurement conversions.\u003c\/h4\u003e\n\u003cp\u003eWhether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801-Hand.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eThe convenience of pre-programmed methods with the option to expand.\u003c\/h4\u003e\n\u003cp\u003eiris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive.\u003c\/p\u003e\n\u003cp\u003eCustomize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers.\u003c\/p\u003e\n\u003cp\u003eEasily access your favorite methods directly from the home screen to save time.\u003c\/p\u003e\n\u003cp\u003eBuilt in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/IRIS-with-light.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eChange sample size easily.\u003c\/h4\u003e\n\u003cp\u003eWith our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Cuvette-Insert-Round.jpg\" alt=\"sides\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eRound\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Cuvette-Insert-Vial.jpg\" alt=\"data logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eVial\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Cuvetter-Insert-Square.jpg\" alt=\"basic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eSquare\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Lamp-removal.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eWorry free replacements.\u003c\/h4\u003e\n\u003cp\u003eiris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Battery.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eDesigned for dynamic environments.\u003c\/h4\u003e\n\u003cp\u003eiris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3, 000 measurements, or 8 hours – well over a full day of use out in the field.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_with-USB-Stick.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eQuality data without the hassle.\u003c\/h4\u003e\n\u003cp\u003eExport your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.\u003c\/p\u003e\n\u003ch4\u003eMenu navigation that makes sense.\u003c\/h4\u003e\n\u003cp\u003eQuickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.\u003c\/p\u003e\n\u003ch4\u003eSort and share your data.\u003c\/h4\u003e\n\u003cp\u003eSave data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Lab.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAll of your important information is easily visible.\u003c\/h4\u003e\n\u003cp\u003eWith a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.\u003c\/p\u003e\n\u003ch4\u003eZero resistance with a capacitive touch pad.\u003c\/h4\u003e\n\u003cp\u003eMenu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI8010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePortable pH Meter - HI8010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eManual, two point, through trimmers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eManual from 0 to 100°C (32 to 212.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C (32 to 212.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1230B PEI body pH probe with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1 x 9V battery approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185x82x53 mm (7.3x3.2x2.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265 g (9.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI8010 is supplied with HI1230B pH electrode, calibration screwdriver, battery and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI8010\" target=\"_blank\" rel=\"noopener\"\u003ePortable pH Meter - HI8010\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871396036977,"sku":"HI801-02","price":403987.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/spectrophotometer-iris-front-hi801_1_1.jpg?v=1792646390"},{"product_id":"marine-nitrite-ultra-low-range-checker-hc-hi764","title":"Marine Nitrite Ultra Low-Range Checker® HC - HI764","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eNitrification is the biological oxidation of ammonia (ammonium ion) into nitrite followed by the oxidation of the nitrites to nitrates. The first step of this 2-step process is carried out in an aquarium by nitrifying bacteria. During this quick process, the ammonium levels drop while the nitrite levels increase. Since nitrite is just as harmful as ammonia, nitrite levels should be maintained at immeasurable levels. A mature biological filter should be able to keep nitrite levels low. Also, if tap water is to be used in an aquarium, it is recommended that it be tested for phosphate, as well as silicate, ammonia, nitrate, nitrite, pH, and alkalinity.\u003c\/p\u003e\n\u003cp\u003eThe HI764 Checker® Handheld Colorimeter bridges the gap between simple chemical test kits and professional instrumentation. Chemical test kits are not very accurate, while professional instrumentation can cost hundreds of dollars and can be time-consuming to calibrate and maintain. Hanna Checker®'s are accurate, affordable and easy to use.\u003c\/p\u003e\n\u003cp\u003eTo begin measurements, first, zero the instrument with your water sample. Next, add the reagent. Last, place the vial into the Checker®, press the button and read the results. It's that easy.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of these Checker®'s fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water quality, Environmental, Plating, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Nitrite Ultra Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI764\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 ppb ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the EPA Diazotization method 354.1.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI764 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, nitrite ULR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI764\" target=\"_blank\" rel=\"noopener\"\u003eMarine Nitrite Ultra Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI764\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871396135281,"sku":"HI764","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi764-checkerhc-front.jpg?v=1792646392"},{"product_id":"iron-low-range-checker-hc-hi746","title":"Iron Low-Range Checker® HC - HI746","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI746 Checker®HC (Handheld Colorimeter) is a simple, accurate and cost-effective way to measure iron in the low range. Naturally present in water in low concentrations, iron may affect the taste of water, as well as stain both laundry and household appliances. Also an indicator of corrosion, iron is monitored in industrial plants and water cooling and heating systems. Designed as a more accurate alternative to chemical test kits, the HI746 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for:Water Quality, Education, Industrial, Municipal Water, Aquarium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI746\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eIron Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI746\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e±20 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the TPTZ method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5 mm (3.4 in. x 2.4 in. x 1.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI746 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, reagents for starter kit for 25 tests, (2) 25 mL glass cylinders with caps, cloth for wiping cuvettes, battery, instructions manual and quick reference.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI746\" target=\"_blank\" rel=\"noopener\"\u003eIron Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI746\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871397577073,"sku":"HI746","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi746-checkerhc-front.jpg?v=1792646404"},{"product_id":"chromium-vi-low-range-checker-tester-hi749","title":"Chromium VI Low-Range Checker\/Tester - HI749","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI749 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure chromium VI. Due to its corrosion-resistant properties, hexavalent chromium plays an important part in the plating industry and cooling towers. However, due to its toxic and carcinogenic nature, chromium VI must be must be sufficiently treated prior to wastewater discharge. Designed as a more accurate alternative to chemical test kits, the HI749 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Education, Industrial, Municipal Water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChromium VI Low-Range Checker\/Tester - HI749\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Range\u003c\/td\u003e\n\u003ctd\u003e0 to 300 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the ASTM, Manual of Water and Environmental Technology, D 1687-92, Diphenylcarbohydrazide method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI749 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, chromium VI LR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI749\" target=\"_blank\" rel=\"noopener\"\u003eChromium VI Low-Range Checker\/Tester - HI749\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871397839217,"sku":"HI749","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi749-checkerhc-front.jpg?v=1792646408"},{"product_id":"chloride-checker-hc-hi753","title":"Chloride Checker® HC - HI753","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI753 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure chloride. As one of the most common anions found in water and wastewater, chloride may have adverse effects on taste, corrode stainless steel, damage metal components in boiler systems, and is toxic to aquatic life. Designed as a more accurate alternative to chemical test kits, the HI753 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChloride Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI753\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±6% of reading ± 0.5 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the mercury(II) thiocyanate method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5 mm (3.4 in. x 2.4 in. x 1.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI753 Checker\u003csup\u003e®\u003c\/sup\u003eHC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), (2) 1 mL Syringes with Tips, (1) 1.5X AAA battery, and an instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI753\" target=\"_blank\" rel=\"noopener\"\u003eChloride Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI753\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871397970289,"sku":"HI753","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi753-checkerhc-front.jpg?v=1792646410"},{"product_id":"total-chlorine-ultra-low-range-checker-hc-hi761","title":"Total Chlorine Ultra Low-Range Checker® HC - HI761","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI761 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure total chlorine. Chlorine is a popular disinfectant used in municipal water, fruits, and vegetables, as well as equipment in the food and beverage industry. Though beneficial in destroying pathogens, levels greater than 4 parts per million (ppm) is harmful to humans and therefore, must be monitored. Designed as a more accurate alternative to chemical test kits, the HI761 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Education, Industrial, Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI761\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine Ultra Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI761\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of USEPA method 330.5, DPD method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI761 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, total ULR chlorine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI761\" target=\"_blank\" rel=\"noopener\"\u003eTotal Chlorine Ultra Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI761\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871401607537,"sku":"HI761","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi761-checkerhc-front.jpg?v=1792646428"}],"url":"https:\/\/hannainst.in\/collections\/industry-industrial.oembed?page=4","provider":"hanna","version":"1.0","type":"link"}