{"title":"Meat","description":"","products":[{"product_id":"portable-meat-ph-meter-hi99163","title":"Portable Meat pH Meter - HI99163","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc232d.jpg\" alt=\"HACCP pH meter for meat\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe FC2323 is an amplified pH electrode with a built-in temperature sensor. This probe is designed with low temperature (LT) glass, a conical tip shape, and is housed in a food grade PVDF body with a removable, piercing stainless steel blade. This electrode also features a unique open junction design in which there a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe's conical tip makes it ideal for pH measurements in meat and semi-solid food samples.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202x-conical-tip.png\" alt=\"conical glass tip\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConical Glass Tip\u003c\/h4\u003e\n\u003cp\u003eThe conical shaped tip design allows for penetration into solids, semi-solids, and emulsions for the direct measurement of pH in food products including meat, cheese, yogurt, and milk.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202x-open-junction.png\" alt=\"open junction reference\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOpen Junction Reference\u003c\/h4\u003e\n\u003cp\u003eThe open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag\/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/pvdf-body.png\" alt=\"pvdf body\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003ePVDF Body\u003c\/h4\u003e\n\u003cp\u003ePolyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eOne or two-point automatic calibration\u003c\/li\u003e\n\u003cli\u003eBEPS - Alerts the user of low battery power that could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eCompact, heavy-duty, and waterproof\u003c\/li\u003e\n\u003cli\u003eBattery % displayed on start-up\u003c\/li\u003e\n\u003cli\u003eHELP feature, displays tutorial messages on LCD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI99163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePortable Meat pH Meter - HI99163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH; -2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH; 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH; ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic ‐5.0 to 105.0 °C\/23.0 to 221.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eprobe condition indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±825 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0°C \/ 23.0 to 221.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (up to 60°C); ±1.0°C (outside) \/ ±1°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eFC2323 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’ cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: after 8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (3) AAA \/ approximately 1400 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e196 g (6.91 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI99163 is supplied with FC2323 pH\/ temperature probe with FC099 stainless steel blade tip, HI70004 pH 4.01 buffer solution sachet (20 mL), HI70007 pH 7.01 buffer solution sachet (20 mL), HI700630 electrode acid cleaning solution sachets for meat, grease and fats (2 x 20 mL), batteries, 100 ml beaker (1), calibration certificates for meter and probe, instructions, and rugged thermoformed carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI99163\" target=\"_blank\" rel=\"noopener\"\u003ePortable Meat pH Meter - HI99163\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871180783985,"sku":"HI99163","price":80565.3,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi99163_c.jpg?v=1792645824"},{"product_id":"t-shaped-fahrenheit-thermometer-125mm-hi145-01","title":"T-Shaped Fahrenheit Thermometer (125mm) - HI145-01","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion,  such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on,  a calibration test is immediately performed. With this unique feature,  the HI145 series performs a self-check of its calibration status and displays it on the LCD,  ensuring accuracy,  repeatability,  and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations,  making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 125 mm (5\") long AISI 316 stainless steel probe. The sharp conical tip provides fast response and improved accuracy over the entire range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI145-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e T-Shaped Fahrenheit Thermometer (125mm) - HI145-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -58.0 to 428°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°F (-58.0 to 199.9°F); 1°F (200 to 428°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.6°F (-4 to 194°F); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 92 x 165 x 38 mm (3.6 x 6.5 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 65 g (2.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-01 is supplied complete with 125 mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI145-01\"\u003eT-Shaped Fahrenheit Thermometer (125mm) - HI145-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871229575537,"sku":"HI145-01","price":6195.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-01_hi145-30_face_1.jpg?v=1792645903"},{"product_id":"t-shaped-fahrenheit-thermometer-300mm-hi145-30","title":"T-Shaped Fahrenheit Thermometer (300mm) - HI145-30","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion,  such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on,  a calibration test is immediately performed. With this unique feature,  the HI145 series performs a self-check of its calibration status and displays it on the LCD,  ensuring accuracy,  repeatability,  and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations,  making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 300 mm (12\") long AISI 316 stainless steel probe,  ideal for monitoring hot liquids,  such as in deep frying and soup preparation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI145-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e T-Shaped Fahrenheit Thermometer (300mm) - HI145-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -58.0 to 428°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°F (-58.0 to 199.9°F); 1°F (200 to 428°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.6°F (-4 to 194°F); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 92 x 340 x 38 mm (3.6 x 13.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 80 g (2.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-30 is supplied complete with 300mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI145-30\"\u003eT-Shaped Fahrenheit Thermometer (300mm) - HI145-30\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871233573233,"sku":"HI145-30","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-30.jpg?v=1792645910"},{"product_id":"pronto-water-resistant-wall-mounted-precision-thermometer-c-hi146-00","title":"Pronto Water-resistant Wall-Mounted Precision Thermometer (°C)  HI146-00","description":"\u003cp\u003eThe HI146-00 is a high accuracy thermometer with a professional grade probe and a flexible 2 m cable.\u003c\/p\u003e\n\u003cp\u003eThe CAL CHECK® feature is incorporated into its function to allow you to confirm the accuracy of the meters any time. You can monitor the exact temperature of any product continuously and easily observe it on the LCD display.\u003c\/p\u003e\n\u003cp\u003eHI-146-00 can be easily carried from station to station or installed in a fixed position using the moulded eye and a wall mount probe holder.\u003c\/p\u003e\n\u003cp\u003eWith its compact and simplified design featuring a fixed stainless steel probe and optional probe holder,  this thermometer is ideal for monitoring the temperatures of liquids,  semi-solids and refrigerated foods.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eKey features\u003c\/li\u003e\n\u003cli\u003eHACCP compliant\u003c\/li\u003e\n\u003cli\u003eCAL CHECK® feature\u003c\/li\u003e\n\u003cli\u003eStainless steel temperature probe\u003c\/li\u003e\n\u003cli\u003eWater resistant\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI146-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pronto Water-resistant Wall-Mounted Precision Thermometer (°C)  HI146-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -50.0 to 150.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.3°C (-20 to 90°C); ±0.5°C (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e stainless steel probe (fixed) with 2 m (6.6’) cable; 160 x dia 3 mm (6.3 x dia 0.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AA \/ approximately 5 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e IP54; 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 86 x 110 x 43 mm (3.4 x 4.3 x 1.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI146-00 (Pronto) is supplied with stainless steel temperature probe, battery and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI146-00\"\u003ePronto Water-resistant Wall-Mounted Precision Thermometer (°C) HI146-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871233606001,"sku":"HI146-00","price":9924.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi146_2.jpg?v=1792645909"},{"product_id":"advanced-ph-orp-benchtop-meter-hi6221-02","title":"Advanced pH\/ORP Benchtop Meter- HI6221-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eLaboratory\u003c\/h2\u003e\n\u003cp\u003eMeasure pH\/mV (pH) or mV\/Rel. mV (ORP) with Temperature\u003c\/p\u003e\n\u003cp\u003eHI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH \/ ORP measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the benchtop meter is delivered with Hanna Instruments HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe.\u003c\/p\u003e\n\u003cp\u003eHI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction reference and HT glass design allow the HI1131B to be used in a wide variety of applications including samples with metals and elevated temperatures. Probe connection to the unit is secured through a galvanically isolated BNC connection. HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221_front-rear.png\" alt=\"front back\" width=\"1250\" height=\"691\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThis system responds to a complex range of measurement and monitoring requirements, providing accuracy, reproducibility, and reliability. HI6221 is supplied with an electrode holder that has a flexible arm. The holder can be mounted quickly and provides secure support for electrodes while taking measurements in sample containers.\u003c\/p\u003e\n\u003ch4\u003eUser interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003cli\u003eThe user can select between five different views:\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH\/mV (pH) or mV\/Rel.mV (ORP) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor and system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic (using temperature probe) or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for pH\/ORP measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e5-point pH calibration with automatic recognition for standard buffers (Hanna and NIST buffers)\u003c\/li\u003e\n\u003cli\u003eChoice of standard or custom buffers for calibration\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLogging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnectivity features \u0026amp; services\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection\u003c\/li\u003e\n\u003cli\u003eUSB type A for USB stick, keyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHelp section for meter guidance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eVideo support presentation of main functionalities\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eCustomize calibration options such as Last Calibration, Automatic, semi-automtic or manual calibration, First Calibration Point, daily or periodic Calibration Reminder, and buffer Groups.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_08_Image_0007.jpg\" alt=\"\" width=\"460\" height=\"276\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_02_Image_0001.png\" alt=\"\" width=\"450\" height=\"450\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eCapacitive touch screen with multi-touch support\u003c\/h2\u003e\n\u003cp\u003eThe benchtop unit has a 7-inch color display with 800 x 480p resolution. The capacitive, multi-touch screen supports video playback and data plotting.\u003c\/p\u003e\n\u003ch2\u003eSystem Menu key\u003c\/h2\u003e\n\u003cp\u003eThis key will enter the system menu where User accounts, System Settings, and Logging can be configured. The Help menu is also accessed on the system menu screen.\u003c\/p\u003e\n\u003ch2\u003eMeasurement setup menu\u003c\/h2\u003e\n\u003cp\u003eOpens sensor setup parameters.\u003c\/p\u003e\n\u003ch2\u003eDirect\/Autohold readings\u003c\/h2\u003e\n\u003cp\u003eWhen Direct\/Autohold is selected, measurement reading is held on display when measurement stability is reached. This option removes the subjective nature of stability as a measurement that has not reached equilibrium will not be used.\u003c\/p\u003e\n\u003cp\u003eWhen not selected, sample measurements are displayed continuously.\u003c\/p\u003e\n\u003ch4\u003eHI6221 is supplied with:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHI1131B pH electrode; HI7662-TW temperature probe\u003c\/li\u003e\n\u003cli\u003epH calibration starter kit consisting of:\u003cul\u003e\n\u003cli\u003epH 4.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 7.01 buffer solution sachet (4 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 10.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHI700601 electrode cleaning solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eHI7082 3.5M KCl electrolyte solution (30 mL)\u003c\/li\u003e\n\u003cli\u003eHI764060 electrode holder\u003c\/li\u003e\n\u003cli\u003eCapillary pipette\u003c\/li\u003e\n\u003cli\u003e24 VDC power adapter\u003c\/li\u003e\n\u003cli\u003eUSB-C to USB-A cable\u003c\/li\u003e\n\u003cli\u003eQuick reference guide with instrument quality certificate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last signiﬁcant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last signiﬁcant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV oﬀset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Calibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003epH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom buﬀers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration 1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOﬀset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDaily: 0 m in. to 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003ePeriodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect; Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Isopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (pH, mV, Rel.mV, Abs.mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eTemperature, Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eLast calibration date, electrode oﬀset, average slope, and electrode condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003epH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle \/ Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003eUsers Up to 9 users and adm in. account (default):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP \/ Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (2.65 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6221-02\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871319884145,"sku":"HI6221-02","price":122546.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221-head-on-700x700-cd07ed0c-fd8c-42df-a0a8-112410be6851_4_2.jpg?v=1792646147"},{"product_id":"advanced-conductivity-benchtop-meter-hi6321","title":"Advanced Conductivity Benchtop Meter - HI6321-02","description":"\u003cp\u003eHI6321 is a streamlined Conductivity\/Resistivity\/TDS\/Salinity\/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity\/ resistivity\/TDS\/salinity probe.\u003c\/p\u003e\n\u003cp\u003eRecommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures.\u003c\/li\u003e\n\u003cli\u003eStandard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for \u0026gt;1Mohm.cm resistivity measurements.\u003c\/li\u003e\n\u003cli\u003eNatural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe result is reliable electrolytic conductivity (EC), TDS (Total Dissolved Solids), resistivity, or Seawater Salinity in percent, psu, or ppt units.\u003c\/p\u003e\n\u003cp\u003eTDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement.\u003c\/p\u003e\n\u003cp\u003eSal psu: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 ℃ and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g\/Kg water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 ℃.\u003c\/p\u003e\n\u003cp\u003eSal ppt: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g\/L and covers 10 to 31 ℃ temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 ℃ and an approximate salinity value of 35 in seawater.\u003c\/p\u003e\n\u003cp\u003eSal %: in this scale 100% salinity is equivalent to roughly 10% solids.\u003c\/p\u003e\n\u003ch2\u003eUser interface\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThe user can select between five different views:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMeasurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure µS\/cm, mS\/cm (Conductivity); ω·cm, kω·cm, Mω·cm (Resistivity); ppm, ppt (TDS); ppt, PSU,\n% (Salinity) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor\nand system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for conductivity measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCalibration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStandard single point salinity calibration in 100% salinity standard, with the reading salinity scale set to %\u003c\/li\u003e\n\u003cli\u003eStandard single or multiple conductivity calibration with standards\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogging\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConnectivity features \u0026amp; services\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection o USB type A for USB stick,\nkeyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 µS\/cm; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 µS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±1 Ω·cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water 0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration points\u003c\/td\u003e\n\u003ctd\u003eAuto standard recognition \/ User standard, Single Point \/ Multi Point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Standard solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 µS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling\u003c\/td\u003e\n\u003ctd\u003erate 1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information Last calibration date, oﬀset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (26.5 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6321\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322734961,"sku":"HI6321-02","price":148128.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6321-right-facing-700x700-d4924805-c4b9-4224-b973-d8a72a57f915.jpg?v=1792646150"},{"product_id":"advanced-dissolved-oxygen-benchtop-meter-with-optical-do-probe-opdo-hi6421","title":"Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®) - HI6421-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHI6421 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated module designed for fresh and saltwater measurements of dissolved oxygen.\u003c\/p\u003e\n\u003cp\u003eHI6421 includes Hanna's HI7641133 optical dissolved oxygen probe (opdo®) that is based on the principle of fluorescence quenching. An immobilized Pt-based luminophore is excited by the light of a blue LED and emits a red light. As oxygen interacts with the luminophore it reduces the intensity and lifetime of the luminescence. The lifetime of the luminescence is measured by a photodetector and is used to calculate the dissolved oxygen concentration.\u003c\/p\u003e\n\u003cp\u003eThe probe is fitted with easy to use Smart Caps (HI764113-1) which lock in place and contain pre-loaded calibration coefficients that are automatically transmitted to the probe. The Smart Cap features an immobilized O₂ sensitive luminophore with rugged insoluble black oxygen permeable protective layer. Over time, the sensor’s optical components can age but are compensated for by using the reference signal to compensate the measuring path. As a result, the sensor provides accurate DO measurements over long periods of time without the need for frequent calibration. Concentration measured. Additional features include built-in methods and calculations for the measurement of BOD (Biological Oxygen Demand), OUR (Oxygen Uptake Rate), and SOUR (Specific Oxygen Update Rate). Pressure compensation is done automatically (built-in barometer) or users have the option to manually enter required value. Pressure is displayed in user-configurable units: mmHg, mbar, kPa, inHg, psi, atm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6321_1p0_1222_WEB.jpg\" alt=\"systemUI\" width=\"700\" height=\"537\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch4\u003eUser interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThe user can select between five different views:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure %Sat, mg\/L, ppm (DO); mg\/L, ppm (BOD); mg\/L (OUR); ppm, mg\/L (SOUR)\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the\nsensor and system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/auto-hold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOne or two points calibration at 0% and\/or 100% saturation\u003c\/li\u003e\n\u003cli\u003eSingle point manual calibration in mg\/L or % saturation using a reference method\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLogging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, auto-hold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and auto-hold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnectivity features \u0026amp; services\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data ta USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection\u003c\/li\u003e\n\u003cli\u003eUSB type A for USB stick, keyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHelp section for meter guidance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eVideo support presentation of main functionalities\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information:\u003c\/h2\u003e\n\u003cp\u003eHI6421 is supplied with HI7641133 optical dissolved oxygen probe (opdo®); HI764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate.\u003c\/p\u003e\n\u003ch2\u003eAccessories:\u003c\/h2\u003e\n\u003cp\u003eHI7641133 optical dissolved oxygen probe (opdo®)\u003cbr\u003e\nHI764113-1 Smart cap with O-ring\u003cbr\u003e\nHI764113-2 Calibration\/storage vessel\u003cbr\u003e\nHI764113-3 Stainless steel protective shield\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003e \u003c\/p\u003e\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo\u003csup\u003e®\u003c\/sup\u003e) - HI6421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO meter Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Meter Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 500.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Accuracy\u003c\/td\u003e\n\u003ctd\u003efrom 0.00 to 20.00 mg\/L (ppm) 1.5 % of reading or ± 0.01 mg\/L (ppm), whichever is greater from 20.00 to 50.00 mg\/L (ppm) ±5 % of reading from 0.0 to 200.0 % saturation ± 1.5 % of reading or ± 0.1 %, whichever is greater from 200.0 to 500.0 % saturation ±5 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Range\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa; 17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least signiﬁcant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Points\u003c\/td\u003e\n\u003ctd\u003eOne or two points automatic calibration at 100% (8.26 mg\/L) and 0% (0 mg\/L). Single point manual using a value entered by the user in % saturation or mg\/L.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Standards\u003c\/td\u003e\n\u003ctd\u003e0 and 100% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic from 0 to 70 PSU (manually set) 0.0 to 70.0 % \/ 0.0 to 45.0 g\/L \/ 0.0 to 42.0 psu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Isopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (DO, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Simple\u003c\/td\u003e\n\u003ctd\u003eGLP Basic view information Last calibration date, oﬀset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Full\u003c\/td\u003e\n\u003ctd\u003eGLP Simple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds \/ 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP \/ Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg (26.5 lbs.)1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6421\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo\u003csup\u003e®\u003c\/sup\u003e) - HI6421\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871326273905,"sku":"HI6421-02","price":215460.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6421.jpg?v=1792646160"},{"product_id":"foodcare-t-type-thermocouple-thermometer-with-detachable-probe-hi935004","title":"Foodcare T-Type Thermocouple Thermometer with Detachable Probe - HI935004","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI935004 is a waterproof portable T-Type thermocouple thermometer made for the food professional that is required to monitor temperature as part of a hazardous analysis of critical control points (HACCP) plan including in food service,  production,  packaging,  transportation,  restaurants or catering. The HI935004,  as a meter,  can measure over a wide range of temperatures from -50.0 ℃ (-58.0 ℉) up to 300 ℃ (572 ℉) and offers a very high accuracy of ±0.4 ℃ (±0.7 ℉). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for abnormal drift of the internal electronics,  battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe is not connected or has been damaged.\u003c\/p\u003e\n\u003cp\u003eHI935004 Foodcare thermometer is supplied with the replaceable FC767PW T-Type thermocouple probe that will reach 90% of the final reading within 15 seconds. The tip of FC767PW is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids. The AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003cp\u003eThe HI935004 with the HI767PW is certified according to EN13485:2001 standard that has strict requirements for accuracy,  response time,  operating and storage conditions as applied to the measurement of product temperature which are intended for use in transportation,  storage and distribution facilities of refrigerated,  frozen or deep-frozen food and ice cream.\u003c\/p\u003e\n\u003cp\u003eThere are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/T-Type-with-Cal-Check.jpg\" alt=\" HI935004 CAL Check\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eThe calibration check (CAL Check) feature of the HI935004 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within ±0.3 ℃. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cp\u003eThe included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%,  a warning symbol will blink to indicate low battery condition. When low battery power may affect your results,  the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\n\u003ch4\u003eMissing or Damaged Probe Messages\u003c\/h4\u003e\n\u003cp\u003eThe \"NO PROBE\" message is displayed on the meter when a thermocouple probe is not attached. If the probe is damaged the message will be displayed along with four blinking dashed lines. For an accurate temperature measurement it is important to know that not only is the meter working properly but that the probe is okay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC766PW.jpg\" alt=\"FC767PW Penetration T-Type Thermocouple Probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFast Response Probe\u003c\/h4\u003e\n\u003cp\u003eFC767PW T-Type thermocouple probe that will reach 90% of the final reading within 15 seconds.\u003c\/p\u003e\n\u003ch4\u003eSmall Penetration Tip\u003c\/h4\u003e\n\u003cp\u003eThe tip of FC767PW is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids.\u003c\/p\u003e\n\u003ch4\u003eAISI316 Stainless Steel Body\u003c\/h4\u003e\n\u003cp\u003eThe AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003ch4\u003eAdditional Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eSupplied with Instrument Quality Certificate\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI935004 with the FC767PW are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA,  or to internationally acceptable physical standards. For traceability,  the HI935004 meter is supplied with an instrument quality certificate including measured values along with reference values.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge LCD\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn enhanced LCD displays the measurement reading in ℃ or ℉,  stability indicator,  error messages,  and low battery indicator.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes,  the indicator disappears and a reading can be taken.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Shut-off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eErgonomic,  rugged,  waterproof (IP65) design\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFor additional protection the HI710027 shockproof rubber boot is available as an accessory.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI935004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Foodcare T-Type Thermocouple Thermometer with Detachable Probe - HI935004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI935004\"\u003eFoodcare T-Type Thermocouple Thermometer with Detachable Probe - HI935004\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871387681137,"sku":"HI935004","price":11479.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi935004-connection.jpg?v=1792646317"},{"product_id":"professional-foodcare-portable-ph-meter-hi98161","title":"Professional Foodcare Portable pH Meter - HI98161","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202.jpg\" alt=\"HACCP pH meter for food and dairy\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe FC2023 is the ideal electrode to measure the pH of milk, yogurt, meats, cheeses, fruit, sushi, rice, jams, jellies, dough, ice cream, yogurt, beverages, and juice.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202x-conical-tip.png\" alt=\"conical glass tip\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConical Glass Tip\u003c\/h4\u003e\n\u003cp\u003eMade from low-temperature glass, the conical shaped tip facilitates penetration of solids, semi-solids, and emulsions to directly measure pH in food products including meat, cheese, yogurt, and milk.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202x-open-junction.png\" alt=\"open junction reference\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOpen Junction Reference\u003c\/h4\u003e\n\u003cp\u003eThe open junction uses a solid gel interface (viscolene) between the sample and the internal Ag\/AgCl reference, preventing silver from entering the sample, preventing clogging for a fast, stable reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/pvdf-body.png\" alt=\"pvdf body\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003ePVDF Body\u003c\/h4\u003e\n\u003cp\u003ePolyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, as well as abrasion, fungal growth, and ultraviolet and nuclear radiation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98161_setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eSetup screen\u003c\/h5\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units, and language for help screens and guides.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98161_Cal-Check.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration\u003c\/h4\u003e\n\u003cp\u003epH calibration features detailed CAL Check™ messages. Users are guided through the calibration procedure with step-by-step on-screen instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98161_GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP\u003c\/h4\u003e\n\u003cp\u003eComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including date, time, offset, slope, and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eContextual help at the press of a button\u003c\/p\u003e\n\u003cp\u003eFive-point pH calibration with seven standard buffers and five custom buffers\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC)\u003c\/p\u003e\n\u003cp\u003eDisplays overall condition of the pH electrode after calibration based on the offset and slope characteristics\u003c\/p\u003e\n\u003cp\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/p\u003e\n\u003cp\u003eAutoHold freezes displayed measurement reading when stable\u003c\/p\u003e\n\u003cp\u003eGLP data including date, time, pH calibration buffers, offset, and slope\u003c\/p\u003e\n\u003cp\u003e200 hour battery life with battery level displayed on measurement screen\u003c\/p\u003e\n\u003cp\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eProfessional Foodcare Portable pH Meter - HI98161\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e10¹² Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.8°F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eFC2023 Foodcare PVDF body, pH electrode with internal temperature sensor, quick connect DIN connector and 1 m (3.3’ cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e200 samples (100 pH and 100 mV range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400gm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98161 is supplied with FC2023 PVDF body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700641 electrode cleaning solution for dairy products sachet (2), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720161 hard carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98161\" target=\"_blank\" rel=\"noopener\"\u003eProfessional Foodcare Portable pH Meter - HI98161\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871387877745,"sku":"HI98161","price":100325.25,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98161.jpg?v=1792646319"},{"product_id":"0-1-resolution-k-type-thermocouple-thermometer-with-high-low-limit-display-hi93531","title":"0.1° Resolution K-Type Thermocouple Thermometer with High\/Low Limit Display - HI93531","description":"\u003cp\u003eThe HI93531 is a 0.1° resolution K-type thermocouple thermometer that can be used with a wide variety of K-type probes. This thermometer offers temperature readouts in both degrees Celsius and Fahrenheit. Featuring up to ±0.5℃ accuracy and high and low limit temperature display,  the HI93531 is perfectly suited for high accuracy temperature measurements in the laboratory or field.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eInterchangeable Probes\u003c\/strong\u003e - A wide range of K-type thermocouple probes are available to meet the specific needs of users. Any of the HI766 series of probes can be interchanged with the HI93531 to measure the temperature of surfaces,  gases,  air,  liquid,  semi-solid samples,  and more.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e℃\/℉ Readout\u003c\/strong\u003e - Measurements can be displayed in either degrees Celsius or Fahrenheit. A simple press of the ℃\/℉ button will switch between the scales.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHigh\/Low Function\u003c\/strong\u003e - The maximum and minimum temperature values are continuously monitored and displayed on the lower portion of the HI93531 LCD display during a measurement session. The CLR button clears the high and low values on the LCD display.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHOLD Function\u003c\/strong\u003e - The HOLD button on the face of the meter freezes the display to allow the user time to record readings. Although the display is frozen,  the meter continues to internally monitor the temperature and update the high and low measurement values.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBattery Error Prevention System (BEPS)\u003c\/strong\u003e - The Battery Error Prevention System detects when the batteries become too weak to ensure reliable measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e - When the battery level is below 10%,  a warning symbol will blink to indicate low battery condition.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 0.1° Resolution K-Type Thermocouple Thermometer with High\/Low Limit Display - HI93531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Range\u003c\/td\u003e\n\u003ctd\u003e -200.0 to 999.9°C and 1000 to 1371°C; -328.0 to 999.9°F and 1000 to 2500°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C (-149.9 to 999.9°C); 0.2°C (-200.0 to -150.0°C); 1°C (outside) 0.1°F (-24.9 to 999.9°F); 0.2°F (-249.9 to -25.0°F); 0.3°F (-328.0 to -250.0°F); 1°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5°C (-100.0 to 999.9°C); ±1°C (outside); ±1°F (-148.0 to 999.9°F); ±1.5°F (outside) (for 1 year, excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e HI766 series K-type thermocouple (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e user selectable: 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AA (3) \/ approximately 500 hours of continuous use (with backlight off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 60°C (14 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 150 x 80 x 36 mm (5.9 x 3.1 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 235 g (8.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI93531 is supplied with batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93531\"\u003e0.1° Resolution K-Type Thermocouple Thermometer with High\/Low Limit Display - HI93531\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871407898993,"sku":"HI93531","price":24102.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93531_manual.jpg?v=1792646473"},{"product_id":"karl-fischer-volumetric-titrator-hi933","title":"Karl Fischer Volumetric Titrator HI933-02","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI903-angle.jpg\" alt=\"HI903 Angled\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eTitrator Capabilities\u003c\/h5\u003e\n\u003ch4\u003eDynamic Titrant Dosing\u003c\/h4\u003e\n\u003cp\u003eThe dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eDrift Rate Compensation\u003c\/h4\u003e\n\u003cp\u003eThe HI903 automatically adjusts the titration calculation to account for the effects of any ambient humidity entering the titration cell. This provides a more accurate result by correcting for water not present in the actual sample.\u003c\/p\u003e\n\u003ch4\u003eTitration Results Averaging\u003c\/h4\u003e\n\u003cp\u003eSuccessive results from a titration method may be averaged with recording of the standard deviation.\u003c\/p\u003e\n\u003ch4\u003eTitrant Recordkeeping\u003c\/h4\u003e\n\u003cp\u003eThe HI903’s titrant database can store information for up to 20 titrants. The database may be programmed to remind a user when to standardize their titrant, reducing error in analysis.\u003c\/p\u003e\n\u003ch4\u003eSelectable Endpoint Criteria\u003c\/h4\u003e\n\u003cp\u003eThe HI903 employs a dual platinum pin electrode for bivoltammetric endpoint determination. Users may choose termination criteria based on mV stability times or drift rates.\u003c\/p\u003e\n\u003ch4\u003eMultistage Cell Preparation\u003c\/h4\u003e\n\u003cp\u003eA pre-titration stage eliminates residual water present in the solvent and the cell, providing a reliable baseline start to analysis. Standby mode then keeps the solvent dry between titrations and when the titrator is not in use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI903_BuretteAndDosing.jpg\" alt=\"Burette and Dosing\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eBurettes \u0026amp; Dosing System\u003c\/h5\u003e\n\u003ch4\u003ePrecision Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eOur unmatched 40, 000 step piston driven pump is capable of delivering as little as 0.125 µL of titrant accurately and precisely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eChemically Resistant Tubing \u0026amp; Syringe\u003c\/h4\u003e\n\u003cp\u003eAspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.\u003c\/p\u003e\n\u003ch4\u003eAnti-Diffusion Dispensing Tip\u003c\/h4\u003e\n\u003cp\u003eA specially designed glass dispensing tip delivers titrant precisely into high turbulence mixing zones, ensuring a rapid reaction. Its angular construction helps prevent titrant from diffusing into the sample solvent.\u003c\/p\u003e\n\u003ch5\u003eTitration \u0026amp; Solvent System\u003c\/h5\u003e\n\u003ch4\u003eEfficient Sample Handling\u003c\/h4\u003e\n\u003cp\u003eThe HI903 features a quick-remove sample port with a replaceable rubber septum allowing for fast and easy sample introduction to the titration vessel. An integrated magnetic stirrer ensures homogeneity for an accurate and speedy reaction.\u003c\/p\u003e\n\u003ch4\u003eChemically Resistant Titration Vessel\u003c\/h4\u003e\n\u003cp\u003eThe glass and PTFE titration cell and fittings are designed to withstand the harsh solvents and reagents involved in Karl Fischer reactions.\u003c\/p\u003e\n\u003ch4\u003eSealed Solvent System\u003c\/h4\u003e\n\u003cp\u003eThe titration vessel is completely sealed to minimize exposure to ambient humidity, keep the system dry, and reduce titrant consumption while saving time between titrations. Solvent may be exchanged in a matter of seconds without opening the titration vessel.\u003c\/p\u003e\n\u003ch4\u003eVisually Recognizable Desiccant\u003c\/h4\u003e\n\u003cp\u003eA rechargeable, color-indicating, silica gel desiccant prevents the ingress of ambient humidity into the sealed system while maintaining full titrator functionality. The desiccant color change allows a user to recognize when it’s adsorption capacity has depleted and is ready for replacement or recharging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI903_TitrationSolventSystem.jpg\" alt=\"Titrant and Solvent System\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screenshots-Array_HI903.jpg\" alt=\"\" width=\"1200\" height=\"574\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eInterface \u0026amp; Display\u003c\/h5\u003e\n\u003ch4\u003eInteractive Color Display\u003c\/h4\u003e\n\u003cp\u003eA large, color LCD screen clearly shows the chosen titration method along with results, units, dosing size, titration volume, drift rate, and mV value.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eDetailed Titration Graphs\u003c\/h4\u003e\n\u003cp\u003eA real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.\u003c\/p\u003e\n\u003ch4\u003eSimple \u0026amp; Quick Navigation\u003c\/h4\u003e\n\u003cp\u003eVirtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.\u003c\/p\u003e\n\u003ch5\u003eData \u0026amp; Storage\u003c\/h5\u003e\n\u003ch4\u003eCustomizable Titration Reports\u003c\/h4\u003e\n\u003cp\u003eEach titration report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application and procedures.\u003c\/p\u003e\n\u003ch4\u003eFlexible GLP Management\u003c\/h4\u003e\n\u003cp\u003eAll necessary GLP (Good Laboratory Practice) information can be recorded with each sample including: sample identification, company and operator name, date, time, and electrode ID codes.\u003c\/p\u003e\n\u003ch4\u003eEffortless Data Transfer\u003c\/h4\u003e\n\u003cp\u003eData can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The USB port allows for the transfer of titration methods, titration reports, and software upgrades via USB flash drive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/USB-Key-copy.jpg\" alt=\"USB Transfer\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eConnectivity \u0026amp; Functionality\u003c\/h5\u003e\n\u003ch4\u003eConfigurable Balance Interface\u003c\/h4\u003e\n\u003cp\u003eSample size may be automatically entered from any laboratory analytical balance with a RS232 serial output saving time and labor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMultiple Peripherals\u003c\/h4\u003e\n\u003cp\u003eUsers can print reports directly from the titrator using a standard parallel printer. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.\u003c\/p\u003e\n\u003ch5\u003eMethods of Analysis\u003c\/h5\u003e\n\u003ch4\u003eCustomizable Methods\u003c\/h4\u003e\n\u003cp\u003eThe HI903 can store up to 100 user-defined or standard titration methods. Each method may be customized and optimized for performance based on application and user requirements.\u003c\/p\u003e\n\u003ch4\u003eTitration Method Support\u003c\/h4\u003e\n\u003cp\u003eOnsite installation, training, and customization is available from one of our Applications or Service experts. Hanna offers continued support via phone or webinar for any questions you might have along the way.\u003c\/p\u003e\n\u003ch4\u003eAdaptable Standard Methods\u003c\/h4\u003e\n\u003cp\u003eOur technical experts can program and customize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI903 Karl Fischer system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/clearbeaker_goldliquid_copy.jpg\" alt=\"Methods of Analysis\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI903-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eKarl Fischer Volumetric Titrator HI903\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eKarl Fischer Volumetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003e100 ppm to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm to 0.0001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Units\u003c\/td\u003e\n\u003ctd\u003e%, ppm, mg\/g, µg\/g, mg, µg, mg\/mL, µg\/mL, mg\/pc, µg\/pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Type\u003c\/td\u003e\n\u003ctd\u003eliquid or solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Titration Conditioning\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackground Drift Correction\u003c\/td\u003e\n\u003ctd\u003eautomatic or user-selectable value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndpoint Criteria\u003c\/td\u003e\n\u003ctd\u003efixed mV persistence, relative drift stop or absolute drift stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Type\u003c\/td\u003e\n\u003ctd\u003edynamic with optional pre-dispensing rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResult Statistics\u003c\/td\u003e\n\u003ctd\u003emean, standard deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full burette volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe\u003c\/td\u003e\n\u003ctd\u003e5 mL precision ground glass with PTFE plunger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve\u003c\/td\u003e\n\u003ctd\u003emotor-driven 3-way, PTFE liquid contact material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTubing\u003c\/td\u003e\n\u003ctd\u003ePTFE with light block and thermal jacketing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispensing Tip\u003c\/td\u003e\n\u003ctd\u003eglass, fixed position, anti-diffusing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Vessel\u003c\/td\u003e\n\u003ctd\u003econical with operation volume between 50-150 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolvent Handling System\u003c\/td\u003e\n\u003ctd\u003esealed system, integrated diaphragm air pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarization Current\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 15, 20, 30 or 40 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e2 mV to 1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette\u003c\/td\u003e\n\u003ctd\u003e5 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Resolution\u003c\/td\u003e\n\u003ctd\u003e1\/40000 of the burette volume (0.125 µL per dose) with 5 mL burette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Type\u003c\/td\u003e\n\u003ctd\u003emagnetic, optically regulated, digital stirrer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Speed\u003c\/td\u003e\n\u003ctd\u003e200 to 2000 rpm; resolution 100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitrator Methods\u003c\/td\u003e\n\u003ctd\u003eup to 100 methods (standard and user-defined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReports\u003c\/td\u003e\n\u003ctd\u003eup to 100 complete titration reports and drift rate reports can be stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP Conformity\u003c\/td\u003e\n\u003ctd\u003eGood Laboratory Practice and instrument data storage and printing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeripheral Devices\u003c\/td\u003e\n\u003ctd\u003econnections for VGA display, PC-keyboard, parallel printer, USB device input, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7 in. (320 x 240 pixel) color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003epolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Portuguese. Spanish, and French\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC; -01models, US plug (type A); -02models, European plug (type C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eoperating: 10 to 40°C (50 to 104°F), up to 95% RH\nstorage: -20 to 70°C (-4 to 158°F), up to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapproximately 10 kg (22 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI903-01\" target=\"_blank\" rel=\"noopener\"\u003eKarl Fischer Volumetric Titrator HI903\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871419826545,"sku":"HI933-02","price":919424.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi903.jpg?v=1792646609"},{"product_id":"foodcare-k-type-thermocouple-thermometer-with-detachable-probe-hi935001","title":"Foodcare K-Type Thermocouple Thermometer with Detachable Probe - HI935001","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI935001 is a waterproof portable K-Type thermocouple thermometer made for the food professional that is required to monitor temperature as part of a hazardous analysis of critical control points (HACCP) plan including in food service,  production,  packaging,  transportation,  restaurants or catering. The HI935001,  as a meter,  can measure over a wide range of temperatures from -50.0 ℃ (-58.0 ℉) up to 300 ℃ (572 ℉) and offers a very high accuracy of ±0.4 ℃ (±0.7 ℉). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for abnormal drift of the internal electronics,  battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe is not connected or has been damaged.\u003c\/p\u003e\n\u003cp\u003eHI935001 Foodcare thermometer is supplied with the replaceable FC766PW K-Type thermocouple probe that will reach 90% of the final reading within 15 seconds. The tip of FC766PW is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids. The AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003cp\u003eThere are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI935001-no-probe-CAL-CHECK.jpg\" alt=\" HI935001 CAL Check\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eThe calibration check (CAL Check) feature of the HI935001 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within ±0.3 ℃. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cp\u003eThe included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%,  a warning symbol will blink to indicate low battery condition. When low battery power may affect your results,  the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\n\u003ch4\u003eMissing or Damaged Probe Messages\u003c\/h4\u003e\n\u003cp\u003eThe \"NO PROBE\" message is displayed on the meter when a thermocouple probe is not attached. If the probe is damaged the message will be displayed along with four blinking dashed lines. For an accurate temperature measurement it is important to know that not only is the meter working properly but that the probe is okay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC766PW.jpg\" alt=\"FC766PW Penetration K-Type Thermocouple Probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFast Response Probe\u003c\/h4\u003e\n\u003cp\u003eFC766PW K-Type thermocouple probe that will reach 90% of the final reading within 15 seconds.\u003c\/p\u003e\n\u003ch4\u003eSmall Penetration Tip\u003c\/h4\u003e\n\u003cp\u003eThe tip of FC766PW is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids.\u003c\/p\u003e\n\u003ch4\u003eAISI316 Stainless Steel Body\u003c\/h4\u003e\n\u003cp\u003eThe AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003ch4\u003eAdditional Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eSupplied with Instrument Quality Certificate\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI935001 with the FC766PW are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA,  or to internationally acceptable physical standards. For traceability,  the HI935001 meter is supplied with an instrument quality certificate including measured values along with reference values.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge LCD\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn enhanced LCD displays the measurement reading in ℃ or ℉,  stability indicator,  error messages,  and low battery indicator.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes,  the indicator disappears and a reading can be taken.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Shut-off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eErgonomic,  rugged,  waterproof (IP65) design\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFor additional protection the HI710027 shockproof rubber boot is available as an accessory.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI935001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Foodcare K-Type Thermocouple Thermometer with Detachable Probe - HI935001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Range\u003c\/td\u003e\n\u003ctd\u003e -50.0 to 199.9 ℃; 200 to 300 ℃ \u003cbr\u003e-58.0 to 399.9 °F; 400 to 572 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 ℃ (-50.0 to 199.9 ℃); 1 ℃ (200 to 300 ℃)\u003cbr\u003e 0.1 °F (-58.0 to 399.9 °F); 1 °F (400 to 572 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.4 ℃ (-50.0 to 300 ℃) \u003cbr\u003e±0.7 °F (-58.0 to 572 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e HI766PW detachable pentration probe (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e user selectable: off, 8 or 60 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA battery (3 pcs.) \/ approximately 3500 hours of continuous use \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e operating conditions: -30 to 50°C (-22 to 122°F); \u003cbr\u003estorage and transportation: -40 to 70°C (-40 to 158°F); \u003cbr\u003erelative humidity: 100% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 140 x 57 x 28 mm (5.5 x 2.2 x 1.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 178 g  (6.27 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI935001 is supplied with FC766PW K-Type thermocouple penetration probe, batteries, instruction manual, and instrument quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI935001\"\u003eFoodcare K-Type Thermocouple Thermometer with Detachable Probe - HI935001\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871423398257,"sku":"HI935001","price":11392.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi935001-fahrenheit.jpg?v=1792646620"},{"product_id":"foodcare-k-type-thermocouple-thermometer-with-ultra-fast-probe-hi9350011","title":"Foodcare K-Type Thermocouple Thermometer with Ultra-Fast Probe - HI9350011","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI9350011 is a waterproof portable K-Type thermocouple thermometer made for the food professional that is required to monitor temperature as part of a hazardous analysis of critical control points (HACCP) plan including in food service,  production,  packaging,  transportation,  restaurants or catering. The HI9350011,  as a meter,  can measure over a wide range of temperatures from -50.0 ℃ (-58.0 ℉) up to 300 ℃ (572 ℉) and offers a very high accuracy of ±0.4 ℃ (±0.7 ℉). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for abnormal drift of the internal electronics,  battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe is not connected or has been damaged.\u003c\/p\u003e\n\u003cp\u003eHI9350011 Foodcare thermometer is supplied with the replaceable FC766C1 K-Type thermocouple probe that will reach 90% of the final reading within 4 seconds. The tip of FC766PW is just 1.6 mm (0.06\") in diameter allowing for easy penetrations into solids and semi-solids. The AISI 316 stainless steel body is 95 mm (3.7\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003cp\u003eThere are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI935001-no-probe-CAL-CHECK.jpg\" alt=\" HI935001 CAL Check\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eThe calibration check (CAL Check) feature of the HI9350011 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within ±0.3 ℃. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cp\u003eThe included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%,  a warning symbol will blink to indicate low battery condition. When low battery power may affect your results,  the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\n\u003ch4\u003eMissing or Damaged Probe Messages\u003c\/h4\u003e\n\u003cp\u003eThe \"NO PROBE\" message is displayed on the meter when a thermocouple probe is not attached. If the probe is damaged the message will be displayed along with four blinking dashed lines. For an accurate temperature measurement it is important to know that not only is the meter working properly but that the probe is okay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC766C1-probe.jpg\" alt=\"FC766C1 Ultra-Fast K-Type Thermocouple Probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eUltra-Fast Response Probe\u003c\/h4\u003e\n\u003cp\u003eFC766C1 K-Type thermocouple probe that will reach 90% of the final reading within 4 seconds.\u003c\/p\u003e\n\u003ch4\u003eSmall Penetration Tip\u003c\/h4\u003e\n\u003cp\u003eThe tip of FC766C1 is just 1.6 mm (0.06\") in diameter allowing for easy penetrations into solids and semi-solids.\u003c\/p\u003e\n\u003ch4\u003eAISI316 Stainless Steel Body\u003c\/h4\u003e\n\u003cp\u003eThe AISI 316 stainless steel body is 95 mm (3.7\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003ch4\u003eAdditional Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eSupplied with Instrument Quality Certificate\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI9350011 with the FC766C1 are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA,  or to internationally acceptable physical standards. For traceability,  the HI935001 meter is supplied with an instrument quality certificate including measured values along with reference values.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge LCD\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn enhanced LCD displays the measurement reading in ℃ or ℉,  stability indicator,  error messages,  and low battery indicator.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes,  the indicator disappears and a reading can be taken.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Shut-off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eErgonomic,  rugged,  waterproof (IP65) design\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFor additional protection the HI710027 shockproof rubber boot is available as an accessory.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI9350011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Foodcare K-Type Thermocouple Thermometer with Ultra-Fast Probe - HI9350011\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Range\u003c\/td\u003e\n\u003ctd\u003e -50.0 to 199.9 ℃; 200 to 300 ℃ \u003cbr\u003e-58.0 to 399.9 °F; 400 to 573 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 ℃ (-50.0 to 199.9 ℃); 1 ℃ (200 to 300 ℃)\u003cbr\u003e 0.1 °F (-58.0 to 399.9 °F); 1 oF (400 to 573 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ± 0.4 ℃ (-50.0 to 300 ℃) \u003cbr\u003e± 0.7°F (-58.0 to 573 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e HI766C1 ultra-fast detachable penetration probe (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e user selectable: off, 8 or 60 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA battery (3 pcs.) \/ approximately 3500 hours of continuous use \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e operating conditions: -30 to 50°C (-22 to 122°F); \u003cbr\u003estorage and transportation: -40 to 70°C (-40 to 158°F); \u003cbr\u003erelative humidity: 100% \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 140 x 57 x 28 mm (5.5 x 2.2 x 1.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 178 g  (6.27 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI9350011 is supplied with FC766C1 ultra-fast K-Type thermocouple penetration probe, batteries, instruction manual, and instrument quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI9350011\"\u003eFoodcare K-Type Thermocouple Thermometer with Ultra-Fast Probe - HI9350011\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871423431025,"sku":"HI9350011","price":12947.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi9350011-celsius_1_1.jpg?v=1792646620"},{"product_id":"foodcare-t-type-thermocouple-thermometer-with-ultra-fast-detachable-probe-hi9350041","title":"Foodcare T-Type Thermocouple Thermometer with Ultra-Fast Detachable Probe - HI9350041","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI9350041 is a waterproof portable T-Type thermocouple thermometer made for the food professional that is required to monitor temperature as part of a hazardous analysis of critical control points (HACCP) plan including in food service, production, packaging, transportation, restaurants or catering. The HI9350041, as a meter, can measure over a wide range of temperatures from -50.0 ℃ (-58.0 ℉) up to 300 ℃ (572 ℉) and offers a very high accuracy of ±0.4 ℃ (±0.7 ℉). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for abnormal drift of the internal electronics, battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe is not connected or has been damaged.\u003c\/p\u003e\n\u003cp\u003eHI9350041 Foodcare thermometer is supplied with the replaceable FC767C1 Ultra-Fast T-Type thermocouple probe that will reach 90% of the final reading within 4 seconds. The tip of FC767C1 is just 1.6 mm (0.06\") in diameter allowing for easy penetrations into solids and semi-solids. The AISI 316 stainless steel body is 95 mm (3.7\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003cp\u003eThe HI9350041 with the HI767C1 is certified according to EN13485:2001 standard that has strict requirements for accuracy, response time, operating and storage conditions as applied to the measurement of product temperature which are intended for use in transportation, storage and distribution facilities of refrigerated, frozen or deep-frozen food and ice cream.\u003c\/p\u003e\n\u003cp\u003eThere are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/T-Type-with-Cal-Check.jpg\" alt=\" HI935004 CAL Check\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eThe calibration check (CAL Check) feature of the HI9350041 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within ±0.3 ℃. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cp\u003eThe included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\n\u003ch4\u003eMissing or Damaged Probe Messages\u003c\/h4\u003e\n\u003cp\u003eThe \"NO PROBE\" message is displayed on the meter when a thermocouple probe is not attached. If the probe is damaged the message will be displayed along with four blinking dashed lines. For an accurate temperature measurement it is important to know that not only is the meter working properly but that the probe is okay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC767C1.jpg\" alt=\"FC767C1 Ultra-Fast T-Type Thermocouple Probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eUltra-Fast Response Probe\u003c\/h4\u003e\n\u003cp\u003eFC767C1 T-Type thermocouple probe is incredibly fast and will reach 90% of the final reading within 4 seconds.\u003c\/p\u003e\n\u003ch4\u003eSmall Penetration Tip\u003c\/h4\u003e\n\u003cp\u003eThe tip of FC767C1 is just 1.6 mm (0.06\") in diameter allowing for easy penetrations into solids and semi-solids.\u003c\/p\u003e\n\u003ch4\u003eAISI316 Stainless Steel Body\u003c\/h4\u003e\n\u003cp\u003eThe AISI 316 stainless steel body is 95 mm (3.7\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003ch4\u003eAdditional Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eSupplied with Instrument Quality Certificate\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI9350041 with the FC767C1 are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA, or to internationally acceptable physical standards. For traceability, the HI9350041 meter is supplied with an instrument quality certificate including measured values along with reference values.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge LCD\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn enhanced LCD displays the measurement reading in ℃ or ℉, stability indicator, error messages, and low battery indicator.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes, the indicator disappears and a reading can be taken.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Shut-off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP65) design\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFor additional protection the HI710027 shockproof rubber boot is available as an accessory.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI9350041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFoodcare T-Type Thermocouple Thermometer with Ultra-Fast Detachable Probe - HI9350041\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-Type Thermocouple Temperature Range\u003c\/td\u003e\n\u003ctd\u003e‑50.0 to 199.9 °C ; 200 to 300 °C\n‑58.0 to 399.9 °F ; 400 to 572 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-Type Thermocouple Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (‑50.0 to 199.9 °C); 1 °C (200 to 300 °C)\n0.1 °F (‑58.0 to 399.9 °F); 1 °F (400 to 572 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eT-Type Thermocouple Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4 °C (‑50.0 to 300 °C)\n±0.7 °F (‑58.0 to 572 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA battery (3 pcs.) \/ approximately 3500 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eclimatic environments: for air (type E)\nrated operating conditions: -20 to 50°C (-4 to 122°F);\nlimiting conditions: -30 to 50°C (-22 to 122°F);\nstorage and transportation conditions: -40 to 70°C (-40 to to 70°C (-40 to 158°F);\nRH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 x 57 x 28 mm (5.5 x 2.2 x 1.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e178 g (6.27 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI9350041 portable T-type thermometer is supplied complete with: HI767C1 ultra-fast temperature probe, batteries, quick reference guide, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI9350041\" target=\"_blank\" rel=\"noopener\"\u003eFoodcare T-Type Thermocouple Thermometer with Ultra-Fast Detachable Probe - HI9350041\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871423463793,"sku":"HI9350041","price":12947.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi9350041_manual.jpg?v=1792646620"},{"product_id":"foodcare-k-type-thermocouple-thermometer-with-fixed-attached-probe-hi935007","title":"Foodcare K-Type Thermocouple Thermometer with Fixed Attached Probe - HI935007","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI935007 is a waterproof portable K-Type thermocouple thermometer made for the food professional that is required to monitor temperature as part of a hazardous analysis of critical control points (HACCP) plan including in food service, production, packaging, transportation, restaurants or catering. The HI935007, as a meter, can measure over a wide range of temperatures from -50.0 ℃ (-58.0 ℉) up to 300 ℃ (572 ℉) and offers a very high accuracy of ±0.4 ℃ (±0.7 ℉). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for abnormal drift of the internal electronics, battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe is not connected or has been damaged.\u003c\/p\u003e\n\u003cp\u003eHI935007 Foodcare thermometer is supplied with a fixed attached penetration K-Type thermocouple probe that will reach 90% of the final reading within 15 seconds. The tip of FC766PW is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids. The AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003cp\u003eThere are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI935001-no-probe-CAL-CHECK.jpg\" alt=\" HI935007 CAL Check\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eThe calibration check (CAL Check) feature of the HI935007 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within ±0.3 ℃. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cp\u003eThe included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%, a warning symbol will blink to indicate low battery condition. When low battery power may affect your results, the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\n\u003ch4\u003eDamaged Probe Messages\u003c\/h4\u003e\n\u003cp\u003eIf the probe is damaged the message will be displayed along with four blinking dashed lines. For an accurate temperature measurement it is important to know that not only is the meter working properly but that the probe is okay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC766PW.jpg\" alt=\"Penetration K-Type Thermocouple Probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFast Response Probe\u003c\/h4\u003e\n\u003cp\u003eThe attached penetration K-Type thermocouple probe that will reach 90% of the final reading within 15 seconds.\u003c\/p\u003e\n\u003ch4\u003eSmall Penetration Tip\u003c\/h4\u003e\n\u003cp\u003eThe tip of the probe is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids.\u003c\/p\u003e\n\u003ch4\u003eAISI316 Stainless Steel Body\u003c\/h4\u003e\n\u003cp\u003eThe AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003ch4\u003eAdditional Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eSupplied with Instrument Quality Certificate\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI935007 with the K-Type penetration probe are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA, or to internationally acceptable physical standards. For traceability, the HI935007 meter is supplied with an instrument quality certificate including measured values along with reference values.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge LCD\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn enhanced LCD displays the measurement reading in ℃ or ℉, stability indicator, error messages, and low battery indicator.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes, the indicator disappears and a reading can be taken.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Shut-off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP65) design\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFor additional protection the HI710027 shockproof rubber boot is available as an accessory.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI935007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFoodcare K-Type Thermocouple Thermometer with Fixed Attached Probe - HI935007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Range\u003c\/td\u003e\n\u003ctd\u003e-50.0 to 199.9 ℃; 200 to 300 ℃\n-58.0 to 399.9 °F; 400 to 573 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ℃ (-50.0 to 199.9 ℃); 1 ℃ (200 to 300 ℃)\n0.1 °F (-58.0 to 399.9 °F); 1 oF (400 to 573 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eK-Type Thermocouple Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.4 ℃ (-50.0 to 300 ℃)\n± 0.7°F (-58.0 to 573 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eK-Type attached penetration probe (fixed)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: off, 8 or 60 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA battery (3 pcs.) \/ approximately 3500 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eoperating conditions: -30 to 50°C (-22 to 122°F);\nstorage and transportation: -40 to 70°C (-40 to 158°F);\nrelative humidity: 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e140 x 57 x 28 mm (5.5 x 2.2 x 1.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e178 g (6.27 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI935007 is supplied with K-Type thermocouple penetration probe, batteries, instruction manual, and instrument quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI935007\" target=\"_blank\" rel=\"noopener\"\u003eFoodcare K-Type Thermocouple Thermometer with Fixed Attached Probe - HI935007\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871423824241,"sku":"HI935007","price":11479.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi935007-celsius.jpg?v=1792646622"},{"product_id":"foodcare-t-type-thermocouple-thermometer-with-fixed-attached-probe-hi935008","title":"Foodcare T-Type Thermocouple Thermometer with Fixed Attached Probe - HI935008","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI935008 is a waterproof portable T-Type thermocouple thermometer made for the food professional that is required to monitor temperature as part of a hazardous analysis of critical control points (HACCP) plan including in food service,  production,  packaging,  transportation,  restaurants or catering. The HI935008,  as a meter,  can measure over a wide range of temperatures from -50.0 ℃ (-58.0 ℉) up to 300 ℃ (572 ℉) and offers a very high accuracy of ±0.4 ℃ (±0.7 ℉). The accuracy of the meter is assured with advanced diagnostic features including CAL-Check that checks for abnormal drift of the internal electronics,  battery error prevention system (BEPS) that will not allow a reading to be taken when there is not sufficient battery power and probe diagnostics that alert the user when the probe has been damaged.\u003c\/p\u003e\n\u003cp\u003eHI935008 Foodcare thermometer is supplied with an attached T-Type thermocouple penetration probe that will reach 90% of the final reading within 15 seconds. The tip of the probe is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids. The AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003cp\u003eThe HI935008 with the fixed attached penetration probe is certified according to EN13485:2001 standard that has strict requirements for accuracy,  response time,  operating and storage conditions as applied to the measurement of product temperature which are intended for use in transportation,  storage and distribution facilities of refrigerated,  frozen or deep-frozen food and ice cream.\u003c\/p\u003e\n\u003cp\u003eThere are many considerations when designing a thermometer for the food professional. Below are features that we considered to be important and beneficial.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/T-Type-with-Cal-Check.jpg\" alt=\" HI935008 CAL Check\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eThe calibration check (CAL Check) feature of the HI935008 is an internal diagnostic feature that checks for any drift in the electronics that occurs with all digital thermometers over time. When the meter is turned CAL Check looks to see if the internal calibration is within ±0.3 ℃. If the drift is greater and error (err) message will be displayed. With CAL Check you can be confident that the meter is working properly.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cp\u003eThe included AAA batteries provide 3500 hours of continuous use. When the battery level is below 10%,  a warning symbol will blink to indicate low battery condition. When low battery power may affect your results,  the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\n\u003ch4\u003eDamaged Probe Messages\u003c\/h4\u003e\n\u003cp\u003eThe \"NO PROBE\" message is displayed on the meter when the signal is interrupted between the probe and meter. If the probe is damaged the message will be displayed along with four blinking dashed lines. For an accurate temperature measurement it is important to know that not only is the meter working properly but that the probe is okay.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC766PW.jpg\" alt=\"Penetration T-Type Thermocouple Probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFast Response Probe\u003c\/h4\u003e\n\u003cp\u003eThe T-Type thermocouple penetration probe that will reach 90% of the final reading within 15 seconds.\u003c\/p\u003e\n\u003ch4\u003eSmall Penetration Tip\u003c\/h4\u003e\n\u003cp\u003eThe tip of the probe is just 3 mm (0.12\") in diameter allowing for easy penetrations into solids and semi-solids.\u003c\/p\u003e\n\u003ch4\u003eAISI316 Stainless Steel Body\u003c\/h4\u003e\n\u003cp\u003eThe AISI 316 stainless steel body is 155 mm (6.1\") long and is safe for food contact in compliance with Regulation (EC) 1935\/2004.\u003c\/p\u003e\n\u003ch4\u003eAdditional Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eSupplied with Instrument Quality Certificate\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI935008 with the attached probe are calibrated according to an ISO9001 calibration system using standards and reference instruments in which the accuracy is traceable the National Institute of Standards (NIST) in the USA,  or to internationally acceptable physical standards. For traceability,  the HI935008 meter is supplied with an instrument quality certificate including measured values along with reference values.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge LCD\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn enhanced LCD displays the measurement reading in ℃ or ℉,  stability indicator,  error messages,  and low battery indicator.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAn hourglass indicator is displayed on the LCD until a stable reading is obtained. Once a reading stabilizes,  the indicator disappears and a reading can be taken.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Shut-off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter can be set to automatically turn off after 8 minutes or 60 minutes to conserve battery life in the event that the meter is left on. The auto-off feature can also be disabled.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eErgonomic,  rugged,  waterproof (IP65) design\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFor additional protection the HI710027 shockproof rubber boot is available as an accessory.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI935008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Foodcare T-Type Thermocouple Thermometer with Fixed Attached Probe - HI935008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI935008\"\u003eFoodcare T-Type Thermocouple Thermometer with Fixed Attached Probe - HI935008\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871423857009,"sku":"HI935008","price":11479.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi935008-celsius.jpg?v=1792646622"},{"product_id":"foodcare-thermistor-thermometer-hi93501","title":"Foodcare Thermistor Thermometer  - HI93501","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/foodcare-thermistor-thermometer-hi93501.jpg\" alt=\"HI93501 Foodcare Thermistor Thermometer CAL Check Feature\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCAL Check™ Feature\u003c\/h4\u003e\n\u003cp\u003eThe HI93501 includes Hanna‘s exclusive CAL Check™ technology. CAL Check™ allows the user to check calibration status. If the meter is calibrated,  the display will automatically show \"0.0℃\" during startup.\u003c\/p\u003e\n\u003ch4\u003eLow Battery Indicator\u003c\/h4\u003e\n\u003cp\u003eThe included AAA batteries provide 4500 hours of continuous use. When the battery level is below 10%,  a warning symbol will blink to indicate low battery condition. When low battery power may affect your results,  the meter will shut down to avoid erroneous readings caused by low battery level.\u003c\/p\u003e\n\u003ch4\u003eAutomatic Shut-off\u003c\/h4\u003e\n\u003cp\u003eThe auto-off feature can be set to shut the meter off at 8 or 60 minutes,  or it can be disabled so that the meter continuously stays on. The auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/connection-hi93501.jpg\" alt=\"HI93501 Foodcare Thermistor Thermometer CAL Check Feature\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt to be Durable\u003c\/h4\u003e\n\u003cp\u003eWaterproof casing and optional shockproof rubber boot offers maximum protection for a durable thermometer than can handle any environment.\u003c\/p\u003e\n\u003ch4\u003ePortable Design\u003c\/h4\u003e\n\u003cp\u003eMade to fit comfortably in your hand for on-the-go testing,  the large LCD display provides at-a-glance readings from any angle.\u003c\/p\u003e\n\u003ch4\u003eSingle Button Operation\u003c\/h4\u003e\n\u003cp\u003eWith single button operation,  temperature measurements could not more simple. This single button turns the meter on and off and allows you to cycle through options when in Setup Mode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/food-probe-fc762pw.png\" alt=\"FC762PW_foodcare_thermistor_penetration_probe\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCompletely Interchangeable Probes\u003c\/h4\u003e\n\u003cp\u003eThe HI93501 works with a wide range of thermistor probes,  including an assortment of specially engineered HI762 probes,  so you can get the right probe for your needs.\u003c\/p\u003e\n\u003ch4\u003eSupplied with the FC762PW\u003c\/h4\u003e\n\u003cp\u003eThe FC762PW is a rugged penetration probe designed for general use. The stainless steel probe is both durable and easy to clean,  the perfect combination to meet the tough environment encountered in the food sector.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Foodcare Thermistor Thermometer  - HI93501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermistor Temperature Range\u003c\/td\u003e\n\u003ctd\u003e -50.0 to 150.0°C \u003cbr\u003e-58.0 to 302.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermistor Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C \u003cbr\u003e  0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermistor Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1°C (-50.0 to 150.0°C) \u003cbr\u003e ±0.2°F (-58.0 to 302.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e  user selectable: 8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e  1.5V AAA (3) \/ approximately 4500 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -20 to 50°C (-4 to 122°F); RH max 100% (Storage Temperature: -40 to 70°C (-40 to 158°F))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e  140 x 57 x 28 mm (5.5 x 2.2 x 1.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 175 g (6.17 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eMeter is supplied complete with HI762PW temperature probe, batteries (3), quick reference guide, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93501\"\u003eFoodcare Thermistor Thermometer - HI93501\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871423889777,"sku":"HI93501","price":11479.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93501-fahrenheit.jpg?v=1792646623"},{"product_id":"digital-refractometer-for-measuring-sodium-chloride-in-food-hi96821","title":"Digital Refractometer for Measuring Sodium Chloride in Food - HI96821","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI96821 portable refractometer converts the refractive index of a food sample to g\/100 g, g\/100 mL, specific gravity and °Baume. These conversions are based on internationally recognized references for unit conversion. The HI96821 is ideal for the analysis of salad dressings, cheeses, condiments, canned and jarred foods, soups, brines and whey. The HI96821 is an easy to use tool for measuring sodium chloride in foods, whether on the production line or in the lab.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for sodium chloride analysis in foods\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eHigh accuracy measurements in g\/100 g, g\/100 mL, specific gravity and °Baume\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMaking a Standard NaCl Solution (g\/100 g)\u003c\/h4\u003e\n\u003cp\u003eTo make an NaCl Solution, follow the procedure below:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePlace container (such as a glass vial or dropper bottle that has a cover) on an analytical balance.\u003c\/li\u003e\n\u003cli\u003eTare the balance.\u003c\/li\u003e\n\u003cli\u003eWeigh out X grams of high purity dried Sodium Chloride (CAS #: 7647-14-5: MW 58.44) directly into a beaker\u003c\/li\u003e\n\u003cli\u003eAdd distilled or deionized water to the beaker so the total weight of the solution is 100g.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eExample 10g\/100 g NaCl:\u003c\/h5\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable width=\"100%\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eNaCl (g)\u003c\/td\u003e\n\u003ctd\u003eWater (g)\u003c\/td\u003e\n\u003ctd\u003eTotal (g)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e10.000\u003c\/td\u003e\n\u003ctd\u003e90.000\u003c\/td\u003e\n\u003ctd\u003e100.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Refractive_Index_Diagrams-94ed188b.jpg\" alt=\"refractive index\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eRefractive Index\u003c\/h2\u003e\n\u003cp\u003eThe HI96821 takes measurements based on a sample’s refractive index. Refractive index is a measurement of how light behaves as it passes through the sample. Depending on the sample’s composition, light will refract and reflect differently. By measuring this activity with a linear image sensor, the sample’s refractive index can be assessed and used to determine its physical properties such as concentration and density. In addition to the linear image sensor, the HI96821 uses an LED light, prism and lens to make measurement possible.\u003c\/p\u003e\n\u003cp\u003eVariations in temperature will affect the accuracy of refractometry readings, so the use of temperature compensation is highly recommended for reliable results. The HI96821 contains a built-in temperature sensor and is programmed with temperature compensation algorithms in accordance with internationally recognized references which vary based on the parameter being measured.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance:\u003c\/h4\u003e\n\u003cp\u003eOne-point calibration\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eCalibrate with distilled or deionized water\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eSmall sample size\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eSample size can be as small as 2 metric drops (100 μl)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC)\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eSamples automatically compensated for temperature variations\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eQuick, accurate results\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eReadings are displayed in approximately 1.5 seconds\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDual-level LCD\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eThe dual-level LCD displays measurement and temperature readings simultaneously\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eStainless steel sample well\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eEasy to clean and corrosion-resistant\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBattery indicators\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eBattery percent level remaining at startup and low battery indicator\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAutomatic shut-off\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eTo conserve battery life the meter shuts off automatically after three minutes of non-use\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eIP65 water resistant protection\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eWater resistant ABS plastic casing designed to perform under laboratory and field conditions.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI96821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eDigital Refractometer for Measuring Sodium Chloride in Food - HI96821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Range\u003c\/td\u003e\n\u003ctd\u003e1.000 to 1.216 Specific Gravity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Specific Gravity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.002 Specific Gravity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSodium Chloride Range\u003c\/td\u003e\n\u003ctd\u003e0 to 28 g\/100 g; 0 to 34 g\/100 mL; 0 to 26 °Baume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSodium Chloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 g\/100 g; 0.1 g\/100 mL; 0.1 °Baume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSodium Chloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 g\/100 g; ±0.2 g\/100 mL; ±0.2 °Baume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80°C (32 to 176°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 °C (±0.5 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic between 0 and 40°C (32 to 104°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter three minutes of inactivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 5000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e192 x 102 x 67 mm (7.6 x 4.01 x 2.6”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e420 g (14.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefractometer Light Source\u003c\/td\u003e\n\u003ctd\u003eyellow LED\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMinimum Sample Volume\u003c\/td\u003e\n\u003ctd\u003e100 µL (to cover prism totally)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Cell\u003c\/td\u003e\n\u003ctd\u003estainless steel ring and flint glass prism\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Time\u003c\/td\u003e\n\u003ctd\u003eapproximately 1.5 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI96821 is supplied with battery and instruction manual\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI96821\" target=\"_blank\" rel=\"noopener\"\u003eDigital Refractometer for Measuring Sodium Chloride in Food - HI96821\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871439028593,"sku":"HI96821","price":27357.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi96821_1.jpg?v=1792646749"},{"product_id":"free-chlorine-and-uhr-total-chlorine-portable-photometer-meter-only-hi97771","title":"Free Chlorine and UHR Total Chlorine Portable Photometer- Meter Only - HI97771","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eChlorine is a common chemical used by for disinfection. High levels of chlorine, whether in liquid or produced by electrolysis of salt, is used in a variety of industries including produce washing, food processing, and the disinfection of medical equipment due to its' effectiveness as a biocide. The 2017 FDA Food Code 4-501.114 states that based on temperature the chlorine concentration of equipment wash water should be between 25 and 100 mg\/L. HI97771 is designed to measure very high concentrations, 500 mg\/L (ppm), of total chlorine in water. This meter also has a free chlorine range and can measure up to 5.00 mg\/L (ppm).\u003c\/p\u003e\n\u003cp\u003eThe HI97771 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods, reviewing GLP data, recalling the last 50 measurements, and customizing the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eHI97771 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/PHOTOMETER-OPTICAL-SYSTEM.jpg\" alt=\"photometer optical system\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cul\u003e\u003cli\u003e\u003cul\u003e\u003cli\u003eLED that generates very little heat\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cul\u003e\u003cli\u003e8 nm narrowband interference filter that is accurate to ±1 nm and offers 25% increase in light efficiency.\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cul\u003e\u003cli\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/1p00mgl-Certificate-Value-Screen.jpg\" alt=\"\" width=\"350\" height=\"202\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eAdvanced features including CAL-Check to verify performance and if necessary, recalibrate.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI97101-Log-Recall-Screen.jpg\" alt=\"\" width=\"350\" height=\"202\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog Regall\u003c\/h4\u003e\n\u003cp\u003eThe Last 50 readings are autmatically stored for review.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Setup-Screen.jpg\" alt=\"method option\" width=\"350\" height=\"202\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSetup Options\u003c\/h4\u003e\n\u003cp\u003eBacklit dot matrix LCD that offers an exceptionally intuitive user interface that is easy to read and understand.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Measure-Tutorial-Screen.jpg\" alt=\"\" width=\"350\" height=\"202\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eTutorial Mode\u003c\/h4\u003e\n\u003cp\u003eTutorial mode for step-by-step instructions to guide a first-time user in how to perform a measurement correctly.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/2c00min-Reaction-Time-Screen.jpg\" alt=\"\" width=\"350\" height=\"202\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReaction Timer\u003c\/h4\u003e\n\u003cp\u003eBuilt-in reaction timer that ensures consistency amongst multiple users.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHI97771  FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch5\u003eStable Light Source:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe internal reference system of the HI97771  photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement..\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh Efficiency Light Source:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh Quality Filters:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGreater Light Yield:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes..\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCAL Check Functionality:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMulitple Measurement Methods:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge Cuvette Size:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe sample cell of the HI97771 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eIntuitive Dot Matrix Display:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe HI97771 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-off Protection:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI97771\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine and Ultra High Range Total Chlorine Portable Photometer - HI97771-meter only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003efree chlorine: adaptation of the EPA 330.5 DPD method total chlorine: adaptation of the Standard Methods for Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-Cl.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003edate, time of last calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eautomatic logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e50 measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA battery (3 pcs.) \/ \u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 15 minutes of inactivity (30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); relative humidity: 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.) with batteries\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI97771 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate HI97771C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI97771\" target=\"_blank\" rel=\"noopener\"\u003eFree Chlorine and Ultra High Range Total Chlorine Portable Photometer - HI97771-meter only\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871449579889,"sku":"HI97771","price":45928.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi97771_angle_1_1_1.jpg?v=1792646859"},{"product_id":"foodcare-meat-ph-tester-hi981036","title":"Foodcare Meat pH Tester - HI981036","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981036-Meat-pH-Tester-NEW-720x720-5090354b-ab96-4127-9a92-77f47ea51d87.jpg\" alt=\"\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eBetter Features for Better Testing\u003c\/h4\u003e\n\u003cp\u003eAn onscreen stability indicator ensures confidence in your results. The selectable auto-off feature prolongs battery life for peace-of-mind and energy savings if the meter is accidentally left on.\u003c\/p\u003e\n\u003ch4\u003ePocket Sized\u003c\/h4\u003e\n\u003cp\u003eThe compact size makes the Meat pH Tester ideal for on-the-go testing. A large LCD display provides at-a-glance readings from any angle and single button operation streamlines the testing process for any user.\u003c\/p\u003e\n\u003ch4\u003eLong Battery Life\u003c\/h4\u003e\n\u003cp\u003eThe included CR2032 Li-ion battery provides up to 1000 hours of continuous use. When the battery needs changing,  a blinking icon battery icon will notify you so you never miss a measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981036-Meat-pH-Tester-Lean-NEW-720x720-5189930a-8c07-4e54-8c9e-05ebb248a938.jpg\" alt=\"\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC2053-Cap-circle.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eUnique Open Junction with Removable Sleeve\u003c\/h4\u003e\n\u003cp\u003eThe outer junction is protected by a sleeve that can be removed to clean the junction.  Electrolyte can be added to refresh the junction, improving the pH measurement and extending the life of the electrode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202x-conical-tip.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConical Glass Tip\u003c\/h4\u003e\n\u003cp\u003eThe conical shaped tip design allows for direct penetration into meat and meat products.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/pvdf-body.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003ePVDF Body\u003c\/h4\u003e\n\u003cp\u003ePolyvinylidene fluoride (PVDF) is a durable food-grade plastic that is resistant to most chemicals and solvents used for disinfection, including chlorine (bleach).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981036-Meat-pH-Tester-Box-open.jpg\" alt=\"\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMeat, Grease, and Fats Cleaning Solution\u003c\/h4\u003e\n\u003cp\u003eYour Meat pH Tester comes with cleaning solution that has been engineered to keep your electrode free from oils and protiens found in meat and meat products. This concentrated combination of detergents cleans your tester quickly and effectively so that your tester stays in optimum condition.\u003c\/p\u003e\n\u003ch4\u003epH 4 \u0026amp; 7 Buffer Sachets\u003c\/h4\u003e\n\u003cp\u003eWhen performing a pH calibration it is important that the correct buffers are used. We include some start buffers to get you going. The single-use sachets are individually sealed so you use fresh buffer each time you calibrate.\u003c\/p\u003e\n\u003ch4\u003eStorage Solution\u003c\/h4\u003e\n\u003cp\u003eProper storage of your electrode will ensure reliable measurements and a longer electrode life. Our storage solution is specially formulated to keep the pH glass hydrated while minimizing organic growth.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFoodcare Meat pH Tester - HI981036\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 12.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH @ 25 °C \/ 77 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two-point with standard buffers (pH 4.01 and 7.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003epH electrode with conical tip and removable sleeve junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: off, 8 or 60 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 lithium ion battery (1) \/ approximately 1000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 95% max\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 x 148 x 21 mm (2 x 5.8 x 0.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e43 g (1.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981036 is supplied with built in Meat pH electrode, HI70004 pH 4.01 buffer solution sachet (2), HI70007 pH 7.01 buffer solution sachet (2), HI700630 acid cleaning solution for meat grease and fats sachet (2), HI9071 bridge electrolyte gel, HI9072 storage solution (13 ml), instruction manual, instrument quality certificate, and plastic carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981036\" target=\"_blank\" rel=\"noopener\"\u003eFoodcare Meat pH Tester - HI981036\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451054449,"sku":"HI981036","price":13385.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981036-meat-ph-tester-battery-compartment_1.jpg?v=1792646877"},{"product_id":"portable-ph-ec-tds-temperature-meter-ec-range-0-to-6000-s-cm-tds-range-0-to-3000-ppm-mg-l-hi9811-51","title":"Portable pH\/EC\/TDS\/Temperature Meter, EC range: 0 to 6000 µS\/cm, TDS range: 0 to 3000 ppm (mg\/L)  - HI9811-51","description":"\u003ch2\u003eDetails\u003c\/h2\u003e\n\u003cp\u003eThe HI9811-5 portable meter features a large LCD which displays either pH, EC, TDS or temperature readings along with tutorial instructions. The HI9811-5 is a simplistic pH\/EC\/TDS meter that is calibrated manually to a single point with the use of two trimmers. pH is calibrated to pH 7.01 while EC\/TDS is calibrated to either 1.41 mS\/cm (1413 µS\/cm) or 1500 ppm. The LCD screen has battery life indicator as well as on-screen tutorial messages.\u003c\/p\u003e\n\u003cp\u003eThe supplied HI1285-5 probe is a polypropylene body, amplified pH electrode with a built-in EC\/TDS and temperature sensors. The amplifier for the pH electrode prevents interference from humidity and electrical noise from common sources including from motors, ballasts or pumps. The HI9811-5 is a versatile meter best suited for agricultural, greenhouse and hydroponic applications.\u003c\/p\u003e\n\u003ch5\u003eHI1285-5 polypropylene body amplified pH electrode with built in EC\/TDS and temperature sensors\u003c\/h5\u003e\n\u003cp\u003eThe HI9811-5 is supplied with a polypropylene body pH\/EC\/TDS\/temperature probe. The pH, EC, TDS, and temperature sensors are housed in a single body that connects to the meter with a DIN connector. This probe is specially engineered with a fiber junction and gel electrolyte to produce a fast response with reduced contamination.\u003c\/p\u003e\n\u003ch5\u003eAmplified pH electrode\u003c\/h5\u003e\n\u003cp\u003eThe pH electrode circuit has a built in amplifier that will reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include motors, ballasts, and pumps which are common in greenhouses.\u003c\/p\u003e\n\u003ch5\u003eAmperometric EC\/TDS sensor\u003c\/h5\u003e\n\u003cp\u003eThe EC\/TDS readings are performed by an amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins is dependent upon the amount of salts (fertilizer) present. A greater amount of salt present results in an increase in conductance.\u003c\/p\u003e\n\u003ch5\u003ePolypropylene body\u003c\/h5\u003e\n\u003cp\u003eThe polypropylene body houses all the sensors in a single body design and is durable. The probe is gel filled for maintenance free operation. It does not have to be refilled periodically.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 sensors in a single probe\u003c\/li\u003e\n\u003cli\u003ePre-amplified pH electrode for resistance to electrical noise\u003c\/li\u003e\n\u003cli\u003eGel filled maintenance free pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures at-a-glance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWater Resistant\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003cul\u003e\u003cli\u003eAll readings are compensated for variations in temperature\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow Battery Indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI9811-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePortable pH\/EC\/TDS\/Temperature Meter - HI9811-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0 to 14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through offset trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e10 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through slope trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e10 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through slope trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003eβ = 2% \/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5 ppm (mg\/L) = 1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 70.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-parameter Probe\u003c\/td\u003e\n\u003ctd\u003eHI1285-5 combination, amplified pH\/EC\/TDS\/temperature probe with built-in temperature sensor, 8-pin DIN connector and 1 m (3.3 in.) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 150 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e230 g (8.1 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI9811-5 is supplied with HI1285-5 multiparameter probe, HI70007 pH 7.01 buffer solution sachet, HI70442 1500 ppm calibration solution sachet, HI70031 1413 µS\/cm calibration solution sachet, HI700661 electrode cleaning solution sachets (2), 9V battery, instructions and rugged carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI9811-5\" target=\"_blank\" rel=\"noopener\"\u003ePortable pH\/EC\/TDS\/Temperature Meter - HI9811-5\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451349361,"sku":"HI9811-51","price":31299.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI9811-51_720x720__42358.jpg?v=1792646881"},{"product_id":"portable-ph-ec-tds-temperature-meter-ec-range-0-to-1990-s-cm-tds-range-0-to-1990-ppm-mg-l-hi9812-51","title":"Portable pH\/EC\/TDS\/Temperature Meter, EC range: 0 to 1990 µS\/cm, TDS range: 0 to 1990 ppm (mg\/L) - HI9812-51","description":"\u003ch2\u003eDetails\u003c\/h2\u003e\n\u003cp\u003eThe HI9812-5 portable meter features a large LCD which displays either pH, EC, TDS or temperature readings along with tutorial instructions. The HI9812-5 is a simplistic pH\/EC\/TDS meter that is calibrated manually to a single point with the use of two trimmers. pH is calibrated to pH 7.01 while EC\/TDS is calibrated to either 1.41 mS\/cm (1413 µS\/cm) or 1500 ppm. The LCD screen has battery life indicator as well as on-screen tutorial messages.\u003c\/p\u003e\n\u003cp\u003eThe supplied HI1285-5 probe is a polypropylene body, amplified pH electrode with a built-in EC\/TDS and temperature sensors. The amplifier for the pH electrode prevents interference from humidity and electrical noise from common sources including from motors, ballasts or pumps. The HI9812-5 is a versatile meter best suited for agricultural, greenhouse and hydroponic applications.\u003c\/p\u003e\n\u003ch5\u003eHI1285-5 polypropylene body amplified pH electrode with built in EC\/TDS and temperature sensors\u003c\/h5\u003e\n\u003cp\u003eThe HI9812-5 is supplied with a polypropylene body pH\/EC\/TDS\/temperature probe. The pH, EC, TDS, and temperature sensors are housed in a single body that connects to the meter with a DIN connector. This probe is specially engineered with a fiber junction and gel electrolyte to produce a fast response with reduced contamination.\u003c\/p\u003e\n\u003ch5\u003eAmplified pH electrode\u003c\/h5\u003e\n\u003cp\u003eThe pH electrode circuit has a built in amplifier that will reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include motors, ballasts, and pumps which are common in greenhouses.\u003c\/p\u003e\n\u003ch5\u003eAmperometric EC\/TDS sensor\u003c\/h5\u003e\n\u003cp\u003eThe EC\/TDS readings are performed by an amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins is dependent upon the amount of salts (fertilizer) present. A greater amount of salt present results in an increase in conductance.\u003c\/p\u003e\n\u003ch5\u003ePolypropylene body\u003c\/h5\u003e\n\u003cp\u003eThe polypropylene body houses all the sensors in a single body design and is durable. The probe is gel filled for maintenance free operation. It does not have to be refilled periodically.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 sensors in a single probe\u003c\/li\u003e\n\u003cli\u003ePre-amplified pH electrode for resistance to electrical noise\u003c\/li\u003e\n\u003cli\u003eGel filled maintenance free pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eFeatures at-a-glance\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWater Resistant\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003cul\u003e\u003cli\u003eAll readings are compensated for variations in temperature\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eLow Battery Indicator\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI9812-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePortable pH\/EC\/TDS\/Temperature Meter - HI9812-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through offset trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic with built in temperature sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e10 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through slope trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e10 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through slope trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003eβ = 2% \/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5 ppm (mg\/L) = 1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-parameter Probe\u003c\/td\u003e\n\u003ctd\u003eHI1285-5 combination, amplified pH\/EC\/TDS\/temperature probe with built-in temperature sensor, 8-pin DIN connector and 1 m (3.3 in.) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 150 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e230 g (8.1 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI9812-5 is supplied with HI1285-5 multiparameter probe, HI70007 pH 7.01 buffer solution sachet, HI70032 1382 ppm calibration solution sachet, HI70031 1413 µS\/cm calibration solution sachet, HI700661 electrode cleaning solution sachets (2), 9V battery, instructions and rugged carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI9812-5\" target=\"_blank\" rel=\"noopener\"\u003ePortable pH\/EC\/TDS\/Temperature Meter - HI9812-5\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451545969,"sku":"HI9812-51","price":31299.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi9812-5_2017.jpg?v=1792646883"},{"product_id":"portable-ph-ec-tds-meter-range-ph-0-0-to-14-0-ph-ec-0-00-to-4-00-ms-cm-tds-0-to-1999-ppm-mg-l-hi9813-51","title":"Portable pH\/EC\/TDS meter, range: pH 0.0 to 14.0 pH EC 0.00 to 4.00 mS\/cm TDS 0 to 1999 ppm (mg\/L) - HI9813-51","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI9813-5 portable meter features a large LCD which displays either pH, EC, TDS or temperature readings along with tutorial instructions. The pH readings are displayed with a 0.1 resolution and an accuracy of ±0.1 pH while the EC and TDS readings are displayed with a 0.01 mS\/cm and 1 ppm (mg\/L) resolution and 2% full-scale accuracy. The EC range of the HI9813-5 is from 0.00 to 4.00 mS\/cm and TDS is from 0 to 1999 ppm. The temperature correction coefficient (β) is fixed at 2 %\/oC and allows for automatic temperature compensated measurements of EC and TDS. The HI9813-5 is a basic pH\/EC\/TDS meter that is calibrated manually to a single point with the use of two trimmers. pH is calibrated to pH 7.01 while EC\/TDS is calibrated to either 1.41 mS\/cm (1413 µS\/cm) or 1500 ppm. The LCD screen has battery life indicator as well as on-screen tutorial messages. The supplied HI1285-5 probe is a polypropylene body, amplified pH electrode with a built-in EC\/TDS and temperature sensors. The amplifier for the pH electrode prevents interference from humidity and electrical noise from common sources including from motors, ballasts or pumps. The HI9813-5 is a versatile meter for the agricultural, greenhouse and hydroponic uses.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1285-5.jpg\" alt=\"hi1285-5 electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eHI1285-5 polypropylene body amplified pH electrode with built-in EC\/TDS and temperature sensors\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe HI9813-5 is supplied with a polypropylene body pH\/EC\/TDS\/temperature probe. The pH, EC, TDS, and temperature sensor are housed in a single body that connects to the meter with a DIN connector.\u003c\/p\u003e\n\u003ch5\u003eAmplified pH electrode\u003c\/h5\u003e\n\u003cp\u003eThe pH electrode circuit has a built-in amplifier that will reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include motors, ballasts, and pumps which are common in greenhouses.\u003c\/p\u003e\n\u003ch5\u003eAmperometric EC\/TDS sensor\u003c\/h5\u003e\n\u003cp\u003eThe EC\/TDS readings are performed by an amperometric sensor. An alternating voltage is applied to the sensor and the amount of current that passes between the two stainless steel pins is dependent upon the amount of salts (fertilizer) present. A greater amount of salt present results in an increase in conductance.\u003c\/p\u003e\n\u003ch5\u003ePolypropylene body\u003c\/h5\u003e\n\u003cp\u003eThe polypropylene body houses all the sensors in a single body design and is durable. The probe is gel filled for maintenance free operation. It does not have to be refilled periodically.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e3 sensors in a single probe\u003c\/li\u003e\n\u003cli\u003ePre-amplified pH electrode for resistance to electrical noise\u003c\/li\u003e\n\u003cli\u003eGel filled maintenance free pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch5\u003eWater Resistant\u003c\/h5\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAll readings are compensated for variations in temperature\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEC to TDS conversion factor\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFactor automatically adjusts from 0.56 to 0.78 based on actual EC readings\u003c\/li\u003e\n\u003cli\u003eFactor based on 442 curve for natural water\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eLow Battery Indicator\u003c\/h5\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI9813-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePortable pH\/EC\/TDS Meter - HI9813-5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through offset trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 4.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through slope trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1999 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, 1-point through slope trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003eβ=2%\/°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003evariable based on reading from 0.56 to 0.72 according to the TDS 442 curve for natural water\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-parameter Probe\u003c\/td\u003e\n\u003ctd\u003eHI 1285-5 combination, amplified pH\/EC\/TDS\/temperature probe with built-in temperature sensor, 8-pin DIN connector and 1 m (3.3 in.) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 150 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e145 x 80 x 36 mm (5.7 x 3.1 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e230 g (8.1 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI9813-5 is supplied with HI 1285-5 pH\/EC\/TDS\/°C probe, HI 70007 pH 7.01 sachet (1), HI 70031 1413 µS\/cm (1.413 mS\/cm) sachet (1), HI 70442 1500 ppm sachet (1), HI 700661 cleaning solution sachet (2), 9V alkaline battery (1) and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI9813-5\" target=\"_blank\" rel=\"noopener\"\u003ePortable pH\/EC\/TDS Meter - HI9813-5\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451808113,"sku":"HI9813-51","price":31299.75,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi9813-5main.jpg?v=1792646887"},{"product_id":"professional-portable-meat-ph-meter-hi98163","title":"Professional Portable Meat pH Meter - HI98163","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eIn the meat processing industry, the monitoring of pH is considered to be of the utmost importance due to its effect on the meat's quality factors including water binding capacity and shelf life. Upon slaughter, biochemical processes begin to break down the meat. Glycolysis begins post-mortem, converting glycogen to lactic acid, reducing the pH of the carcass. Depending on a number of factors such as type of animal and even breed, this decrease in pH can take anywhere from a single hour to many. It is vital to monitor pH during this phase as once the lowest pH value is reached, the pH will begin to slowly rise, indicating that decomposition has begun.\u003c\/p\u003e\n\u003cp\u003eThe pH value of meat influences its' water binding capacity which directly impacts consumer qualities such as tenderness and color. Lower pH values result in a lower water-binding capacity and lighter colors. Factors such as these can be important when considering how to efficiently produce meat products. For example, when producing dry sausages the meat must have a low water binding capacity so that it can dry evenly.\u003c\/p\u003e\n\u003cp\u003eDepending on the type of the final product and the steps required to get there, pH values will vary throughout the meat processing industry. It is imperative, regardless of the final product, that pH be maintained at a low value to prevent bacterial spoilage and comply with food safety regulations. By monitoring pH values throughout the meat production process, you can ensure the creation of consistent and safe meat products.\u003c\/p\u003e\n\u003cp\u003eMeat products can provide a number of challenges for the person that needs to measure pH. Oils and solids from the meat can coat the sensitive glass membrane surface and\/or clog the reference junction. The FC2323 that is supplied with the HI98163 is designed specifically for measuring pH in meat. Design considerations include a stainless steel piercing blade around conic tip shape probe for easy penetration, an open junction that resist clogging, and a Polyvinylidene Fluoride (PVDF) food grade plastic body that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth. The FC2323 is an ideal general-purpose pH electrode for meat that connects to the HI98163 with a quick-connect, waterproof DIN connector, allowing for a secure, non-threaded attachment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc232d.jpg\" alt=\"HACCP pH meter for meat\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe FC2323 is an amplified pH electrode with a built-in temperature sensor. This probe is designed with low temperature (LT) glass, a conical tip shape, and is housed in a food grade PVDF body with a removable, piercing stainless steel blade. This electrode also features a unique open junction design in which there a viscolene (hard gel) electrolyte layer that is free of silver chloride (AgCl) between the sample to be measured and the internal reference cell. The open junction design resists clogging and the probe's conical tip makes it ideal for pH measurements in meat and semi-solid food samples.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202x-conical-tip.png\" alt=\"conical glass tip\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eConical Glass Tip\u003c\/h4\u003e\n\u003cp\u003eThe conical shaped tip design allows for penetration into solids, semi-solids, and emulsions for the direct measurement of pH in food products including meat, cheese, yogurt, and milk.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc202x-open-junction.png\" alt=\"open junction reference\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOpen Junction Reference\u003c\/h4\u003e\n\u003cp\u003eThe open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag\/AgCl reference. This interface not only prevents silver from entering the sample, but also makes it impermeable to clogging, resulting in a fast response and stable reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/pvdf-body.png\" alt=\"pvdf body\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003ePVDF Body\u003c\/h4\u003e\n\u003cp\u003ePolyvinylidene fluoride (PVDF) is a food grade plastic that is resistant to most chemicals and solvents, including sodium hypochlorite. It has high abrasion resistance, mechanical strength and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.\u003c\/p\u003e\n\u003cp\u003eBesides being supplied with a unique pH electrode for meat, the HI98163 has the Hanna's unique CAL Check™ feature that alerts the user to potential problems during the calibration process. This is a very important for the food processor since it is likely that the probe will be coated with the solids found in the food product being measured. This coating can easily lead to errors in pH measurement. By comparing previous calibration data to the current calibration, the meter will inform the user, with display prompts, when the probe needs to be cleaned, replaced, or if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed on screen as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode, both of which can be found in the GLP data.\u003c\/p\u003e\n\u003cp\u003ePressing the \"AutoHold\" virtual key in measurement mode, the meter will freeze and automatically log a stable reading. An \"out of calibration range\" warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.\u003c\/p\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 200 samples. The logged data, along with the associated GLP data, can then be recalled or transferred to a PC with Hanna's HI920015 micro USB cable and HI92000 software for traceability in record keeping for specific product batches. GLP data includes date, time, calibration buffers, offset, and slope, and is directly accessible by pressing the dedicated GLP key.\u003c\/p\u003e\n\u003cp\u003eA contextual help menu based on the screen that is currently being viewed can be accessed at any time by the press of a dedicated button.\u003c\/p\u003e\n\u003cp\u003eThe high contrast, graphic LCD screen is easy to view outdoors in bright sunlight as well as in low-lit areas with the backlight. A combination of dedicated and virtual keys allows for easy, intuitive meter operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eThe compact, durable HI720161 carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions and cleaning solutions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98161_setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSetup screen\u003c\/h4\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98161_Cal-Check.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration\u003c\/h4\u003e\n\u003cp\u003epH calibration features detailed CAL Check™ messages. Users are guided through the calibration procedure with step-by-step on-screen instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98161_GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP\u003c\/h4\u003e\n\u003cp\u003eComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003eSupplied with FC2323 Foodcare pH\/Temperature electrode\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBody made of food grade PVDF plastic\u003c\/li\u003e\n\u003cli\u003ePiercing stainless steel blade for easy penetration into meats\u003c\/li\u003e\n\u003cli\u003eOpen junction design that resist clogging from food solids\u003c\/li\u003e\n\u003cli\u003eLow temperature pH sensing glass suitable for refrigerated products\u003c\/li\u003e\n\u003cli\u003eBuilt in temperature sensor for temperature compensated measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFive-point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eCAL Check\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination\u003c\/li\u003e\n\u003cli\u003eDisplays overall condition of the pH electrode after calibration that is based on the offset and slope characteristics\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes displayed measurement reading upon stabilization\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP Features\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eGLP data including date, time, pH calibration buffers, offset, and slope\u003c\/li\u003e\n\u003cli\u003eGLP data stored with logged data for traceability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200 hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eProfessional Portable Meat pH Meter - HI98163\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e10¹² Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.8°F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eFC2323 Foodcare PVDF body, pH electrode with internal temperature sensor, quick connect DIN connector and 1 m (3.3’ cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e200 samples (100 pH and 100 mV range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98163 is supplied with FC2323 PVDF body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700630 electrode acid cleaning solution for meat grease and fat deposits sachet (2), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual with quick start guide, instrument quality certificate and HI720161 hard carrying case\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98163\" target=\"_blank\" rel=\"noopener\"\u003eProfessional Portable Meat pH Meter - HI98163\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871452561777,"sku":"HI98163","price":100325.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98163.jpg?v=1792646899"},{"product_id":"checktemp-digital-thermometer-hi98501","title":"Checktemp® Digital Thermometer - HI98501","description":"\u003cp\u003eThe HI 98501 Checktemp® is a digital thermometer with stainless steel penetration probe. It delivers high accuracy temperature measurements over a wide temperature range without worrying about breakage or condensation.\u003c\/p\u003e\n\u003cp\u003eThe Checktemp® offers NO breakage, NO waste, NO injuries and NO difficulty in reading; the digital display prevents a parallax error (observing the wrong measurement due to the angle of view) and is optimized for a wide range of environmental temperatures. Checktemp® is provided with Hanna’s unique CAL Check™ function for accurate measurements every time. The Checktemp® implements a CAL Check™ upon startup and reports the status as 0 or Err.\u003c\/p\u003e\n\u003cp\u003eThe sharp-tip probe of the Checktemp® easily penetrates semi-solid products making routine temperature checks simple and quick for both incoming and outgoing goods. Checktemp® is the ideal instrument for measuring temperature according to HACCP requirements.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2℃ (±0.5℉) - Accuracy\u003c\/li\u003e\n\u003cli\u003eMost accurate temperature tester in the world\u003c\/li\u003e\n\u003cli\u003eCAL Check™ - Automatically verifies calibration at startup\u003c\/li\u003e\n\u003cli\u003e℃\/℉ Status – User selectable\u003c\/li\u003e\n\u003cli\u003eLarge display with wide environmental temperature range and viewing angle.\u003c\/li\u003e\n\u003cli\u003eIP 65 water resistant protection\u003c\/li\u003e\n\u003cli\u003eHACCP Compatible - Use as a tool for control in HACCP analysis\u003c\/li\u003e\n\u003cli\u003eAISI 316 stainless steel penetration Probe\u003c\/li\u003e\n\u003cli\u003e3000 hours of battery life (Continuous use)\u003c\/li\u003e\n\u003cli\u003eAuto-Off (select from 8 min., 60 min., or turn the feature off)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChecktemp\u003csup\u003e®\u003c\/sup\u003e Digital Thermometer - HI98501\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-50.0 to 150.0 ºC \/ -58.0 to 302 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ºC (-50.0 to 150.0 ºC)\n0.1 ºF (-58.0 to 199.9 ºF) \/ 1 ºF (above 200 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 ºC (-30.0 to 120.0 ºC)\n±0.3 ºC (outside: -50.0 to -30.0 ºC and 120.0 to 150.0 ºC)\n±0.5 ºF (-22.0 to 199.9 ºF)\n±1 ºF (outside: -58.0 to -22.0 ºF and 200 to 302 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e8 min (default), 60 min or OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1 x CR2032; approx. 2000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 ºC (-22 to 122 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 x 185 x 21 mm (2 x 7.3 x 0.9“)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e50 g (1.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eCertification: EN 13485:2001 - Suitability: Storage; Environment: E; Accuracy Class: 0.5; IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98501\" target=\"_blank\" rel=\"noopener\"\u003eChecktemp\u003csup\u003e®\u003c\/sup\u003e Digital Thermometer - HI98501\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871455510897,"sku":"HI98501","price":4903.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98501.jpg?v=1792646925"},{"product_id":"checktemp-1-digital-thermometer-hi98509","title":"Checktemp® 1 Digital Thermometer - HI98509","description":"\u003cp\u003eThe Checktemp® 1 Digital Thermometer - HI98509 is a high-accuracy thermometer with a 1 m (3.3') flexible, silicone cable connecting the meter and the stainless steel probe. The sharp-tip penetration probe easily lances semi-solid products such as fruits, vegetables, and cheeses. This probe can also handle liquid, air and measurements in frozen materials. The probe incorporates an NTC thermistor sensor to measure the temperature.\u003c\/p\u003e\n\u003cp\u003eThermistors make it possible to obtain extremely high accuracy in a very short period of time. The Hanna CAL Check™ feature has been incorporated into the Checktemp®1 for reliable and accurate measurements. CAL Check™ automatically runs a self-check upon startup and reports status back to the user; \"-0-\" for ok and \"Err\" if something is wrong.\u003c\/p\u003e\n\u003cp\u003eChecktemp®1 makes routine controls fast and simple for both incoming and outgoing goods. Constructed of AISI 316 stainless steel material, this probe is in compliance with food regulations, making it an ideal instrument for measuring temperature according to HACCP requirements.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003e±0.2℃ (±0.5℉) - Accuracy\u003c\/li\u003e\n\u003cli\u003eMost accurate temperature tester in the world\u003c\/li\u003e\n\u003cli\u003eCAL Check™ - Automatically verifies calibration at startup\u003c\/li\u003e\n\u003cli\u003eSilicone probe cable - 3.3' silicone cable maintains flexibility and performance\u003c\/li\u003e\n\u003cli\u003e℃\/℉ Status – User selectable\u003c\/li\u003e\n\u003cli\u003eLarge display with wide environmental temperature range and viewing angle.\u003c\/li\u003e\n\u003cli\u003eIP 65 water resistant protection\u003c\/li\u003e\n\u003cli\u003eHACCP Compatible - Use as a tool for control in HACCP analysis\u003c\/li\u003e\n\u003cli\u003eAISI 316 stainless steel penetration Probe\u003c\/li\u003e\n\u003cli\u003eAuto-Off (select from 8 min., 60 min., or turn the feature off)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChecktemp\u003csup\u003e®\u003c\/sup\u003e 1 Digital Thermometer - HI98509\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-50.0 to 150.0 ºC \/ -58.0 to 302 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ºC (-50.0 to 150.0 ºC)\n0.1 ºF (-58.0 to 199.9 ºF) \/ 1 ºF (above 200 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 ºC (-30.0 to 120.0 ºC)\n±0.3 ºC (outside: -50.0 to -30.0 ºC and 120.0 to 150.0 ºC)\n±0.5 ºF (-22.0 to 199.9 ºF)\n±1 ºF (outside: -58.0 to -22.0 ºF and 200 to 302 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003estainless steel, 1 m (3.3 in.) cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e8 min (default), 60 min or OFF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3 x 1.5 V AAA alkaline; approx. 2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-30 to 50 ºC (-22 to 122 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107 x 59 x 17 mm (4.2 x 5.3 x 0.7 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e130 g (4.6 oz.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eCertication: EN 13485:2001 - Suitability: Storage; Environment: E; Accuracy Class: 0.5; Protection: IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98509\" target=\"_blank\" rel=\"noopener\"\u003eChecktemp\u003csup\u003e®\u003c\/sup\u003e 1 Digital Thermometer - HI98509\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871455576433,"sku":"HI98509","price":5093.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98509_checktemp-1-front_1_1.jpg?v=1792646924"}],"url":"https:\/\/hannainst.in\/collections\/industry-meat.oembed","provider":"hanna","version":"1.0","type":"link"}