{"title":"Pool, spa, and cold plunge","description":"","products":[{"product_id":"pool-line-ph-controller-and-dosing-pump-bl100-meter-and-probe","title":"Pool Line pH Controller and Dosing Pump - BL100-Meter and probe - BL100-00","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eBL100 pH Controller and Dosing Pump is a system engineered for maintaining the pH of swimming pools,  hot tubs,  and spas. Typically chlorine,  whether liquid or solid,  is alkaline and will raise the pH of the water that it is added to. As the pH increases above pH 7.4,  a form of chlorine known as hypochlorite ion (OCl\u003csup\u003e-\u003c\/sup\u003e) increases. This form of chlorine is 100 time less effective at killing bacteria as compared to the other form of chlorine known as hypochlorous acid (HOCl). For this reason it is important to maintain the correct pH level in order to ensure that the more powerful hypochlorous acid form is available for disinfection. The BL100 was developed to be an inexpensive solution for the consumer to maintain the ideal pH at all times. Simply insert the probe and injection valve in-line with the recirculation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl100.gif\" alt=\"''\" width=\"1000\" height=\"1001\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe BL100 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth pH and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level alarms for pH. When an alarm is activated,  all dosing will stop. For added safety,  the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-flow.jpg\" alt=\"flow rate\" width=\"1000\" height=\"727\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate,  like the proportional band,  allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-proportional.jpg\" alt=\"Automatic Proportional Pump Control\" width=\"1000\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed,  will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-level.jpg\" alt=\" Acid Tank Level\/Flow Switch Input\" width=\"1000\" height=\"725\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/peristaltic-pump.jpg\" alt=\"Pooline Peristaltic Pump\" width=\"1000\" height=\"1000\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe BL100 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Persitaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL100-HI10053_flowcellprobe.jpg\" alt=\"pH probe mounted in flow thorugh cell\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003epH electrode with flow cell\u003c\/h5\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe BL100 is available in multiple configurations including a meter only,  meter and probe,  and\n a complete package that includes bypass loop\n and panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI10053 Amplified pH\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe BL100 uses the HI10053 amplified probe that incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector. The built in amplifier helps to reduce electrical noise from recirculation pumps to provide for a stable,  reliable measurement. The pH glass used is ideal for low conductivity water and provides for fast response..\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL100-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line pH Controller and Dosing Pump - BL100-Meter and probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.10 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e User calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH) \u003cbr\u003eProcess calibration: single point, adjustable (±0.50 pH around measured pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 6.00 to 8.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Proportional Band\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0.10 to 2.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e adjustable 0.10 to 1.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0 °C (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5 °C (±0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e proportional and on\/off control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records a set of consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e external switches can be connected to hold the control due to external events (low reagent level, recirculation pump doesn't work)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted with built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e HI10053 pH\/temperature probe with quick connect DIN connector (supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F), max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL100-00 is supplied with BL100 controller, HI10053 pH\/temperature probe, 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003e\u003cbr\u003eBL100-10 is supplied with BL100 controller, HI10053 pH\/temperature probe, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003e\u003cbr\u003eBL100-20 is supplied with BL100 controller, HI10053 pH\/temperature probe, panel mounted flow cell assembly, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL100-00\"\u003ePool Line pH Controller and Dosing Pump - BL100-Meter and probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159026033,"sku":"BL100-00","price":39804.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl100-hi10053_flowcellprobe_1.jpg?v=1792645790"},{"product_id":"pool-line-orp-controller-and-dosing-pump-bl101-meter-and-probe","title":"Pool Line ORP Controller and Dosing Pump - BL101-Meter and probe - BL101-00","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eBL101 ORP Controller and Dosing Pump is a system engineered for maintaining the ORP of swimming pools,  hot tubs,  and spas. Typically liquid chlorine is used as a disinfectant to keep the water safe from harmful bacteria. Chlorine,  as an oxidizer,  will increase the oxidation- reduction potential (ORP) of water when it is added to it. When the ORP value is greater than 650mV then bacteria that are present will be killed within seconds. The BL101 was developed to be an inexpensive solution for the consumer to maintain the ideal ORP value at all times. Simply insert the probe and injection valve in-line with the re-circulation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL101.gif\" alt=\"\" width=\"1000\" height=\"1001\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe BL101 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth ORP (mV) and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level alarms for ORP. When an alarm is activated,  all dosing will stop. For added safety,  the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-flow.jpg\" alt=\"flow rate\" width=\"1000\" height=\"727\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate,  like the proportional band,  allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-proportional.jpg\" alt=\"Automatic Proportional Pump Control\" width=\"1000\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed,  will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-level.jpg\" alt=\" Acid Tank Level\/Flow Switch Input\" width=\"1000\" height=\"725\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOxidation Chemical Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL101 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ORP-peristaltic-pump.jpg\" alt=\"Pooline ORP Peristaltic Pump\" width=\"1000\" height=\"1000\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe BL101 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line. The loss of prime can be problematic with a diaphragm pump due to the gassing of chlorine.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have any gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Persitaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL100-HI10053_flowcellprobe.jpg\" alt=\"pH probe mounted in flow thorugh cell\" width=\"720\" height=\"720\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eORP electrode with flow cell\u003c\/h4\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe BL101 is available in multiple configurations including a meter only,  meter and probe,  and\n a complete package that includes bypass loop\nand panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI10053 ORP\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe BL101 uses the HI20083 amplified probe that incorporates both ORP and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL101-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line ORP Controller and Dosing Pump - BL101-Meter and probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e -2000 to 2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Calibration\u003c\/td\u003e\n\u003ctd\u003e process calibration: single point, adjustable (± 50 mV around measured ORP value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e High or Low Mode Operation \u003cbr\u003eHigh set point dosing is activated when reading is higher than set point \u003cbr\u003e Low set point dosing is activated when reading is lower than set point (dose oxidizer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e On\/Off control using adjustable set point (200 to 900 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Proportional Band\u003c\/td\u003e\n\u003ctd\u003e adjustable proportional band (10 to 200 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e adjustable hysteresis (10-100 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0 °C (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5 °C (±0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e proportional and on\/off control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records a set of consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e external switches can be connected to hold the control due to external events (low reagent level, recirculation pump doesn't work)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted with built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e selectable flow rate (0.5 to 3.5 L \/ hour; 0.13 to 0.96 g\/hour) \u003cbr\u003emanual control for pump priming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003e HI20083 ORP\/temperature probe with quick connect DIN connector (supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F), max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL101-00 is supplied with BL101 controller, HI20083 ORP\/temperature probe, ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003eBL101-10 is supplied with BL101 controller, HI20083 ORP\/temperature probe, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003eBL101-20 is supplied with BL101 controller, HI20083 ORP\/temperature probe, panel mounted flow cell assembly, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (15 m), tubing adapter 1\/2” - 6 mm with racord (2), ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL101-00\"\u003ePool Line ORP Controller and Dosing Pump - BL101-Meter and probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159189873,"sku":"BL101-00","price":39804.0,"currency_code":"INR","in_stock":true}]},{"product_id":"pool-line-ph-controller-and-dosing-pump-bl100","title":"Pool Line pH Controller and Dosing Pump - BL100","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eBL100 pH Controller and Dosing Pump is a system engineered for maintaining the pH of swimming pools, hot tubs, and spas. Typically chlorine, whether liquid or solid, is alkaline and will raise the pH of the water that it is added to. As the pH increases above pH 7.4, a form of chlorine known as hypochlorite ion (OCl\u003csup\u003e-\u003c\/sup\u003e) increases. This form of chlorine is 100 time less effective at killing bacteria as compared to the other form of chlorine known as hypochlorous acid (HOCl). For this reason it is important to maintain the correct pH level in order to ensure that the more powerful hypochlorous acid form is available for disinfection. The BL100 was developed to be an inexpensive solution for the consumer to maintain the ideal pH at all times. Simply insert the probe and injection valve in-line with the recirculation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl100.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe BL100 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth pH and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level alarms for pH. When an alarm is activated, all dosing will stop. For added safety, the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-flow.jpg\" alt=\"flow rate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-proportional.jpg\" alt=\"Automatic Proportional Pump Control\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed, will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-level.jpg\" alt=\" Acid Tank Level\/Flow Switch Input\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAcid Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL100 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/peristaltic-pump.jpg\" alt=\"Pooline Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe BL100 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have nay gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Peristaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL100-HI10053_flowcellprobe.jpg\" alt=\"pH probe mounted in flow thorugh cell\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003epH electrode with flow cell\u003c\/h5\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe BL100 is available in multiple configurations including a meter only, meter and probe, and\u003cbr\u003e\na complete package that includes bypass loop\u003cbr\u003e\nand panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI10053 Amplified pH\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe BL100 uses the HI10053 amplified probe that incorporates both pH and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector. The built in amplifier helps to reduce electrical noise from recirculation pumps to provide for a stable, reliable measurement. The pH glass used is ideal for low conductivity water and provides for fast response..\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL100-web\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line pH Controller and Dosing Pump - BL100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.10 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e User calibration: automatic, one or two-point with buffer solution (4.01, 7.01, 10.01 pH) \u003cbr\u003eProcess calibration: single point, adjustable (±0.50 pH around measured pH)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e Automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 6.00 to 8.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Proportional Band\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0.10 to 2.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e adjustable 0.10 to 1.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0 °C (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5 °C (±0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e proportional and on\/off control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records a set of consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e external switches can be connected to hold the control due to external events (low reagent level, recirculation pump doesn't work)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted with built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e HI10053 pH\/temperature probe with quick connect DIN connector (supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F), max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL100-00 is supplied with BL100 controller, HI10053 pH\/temperature probe, 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003e\u003cbr\u003eBL100-10 is supplied with BL100 controller, HI10053 pH\/temperature probe, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003e\u003cbr\u003eBL100-20 is supplied with BL100 controller, HI10053 pH\/temperature probe, panel mounted flow cell assembly, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), 20 ml sachet of pH 7.01 buffer (3), 20 ml sachet of pH 4.01 buffer (3), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL100-web\"\u003ePool Line pH Controller and Dosing Pump - BL100\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159714161,"sku":"BL100","price":40702.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl100_front.jpg?v=1792645794"},{"product_id":"pool-line-orp-controller-and-dosing-pump-bl101","title":"Pool Line ORP Controller and Dosing Pump - BL101","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eBL101 ORP Controller and Dosing Pump is a system engineered for maintaining the ORP of swimming pools,  hot tubs,  and spas. Typically liquid chlorine is used as a disinfectant to keep the water safe from harmful bacteria. Chlorine,  as an oxidizer,  will increase the oxidation- reduction potential (ORP) of water when it is added to it. When the ORP value is greater than 650mV then bacteria that are present will be killed within seconds. The BL101 was developed to be an inexpensive solution for the consumer to maintain the ideal ORP value at all times. Simply insert the probe and injection valve in-line with the re-circulation pump and provide the chemical to be dosed.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL101.gif\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMulti-color LCD\u003c\/h4\u003e\n\u003cp\u003eThe BL101 features a multi-colored LCD that provides for a quick way to see the status of the pool controller. If in control mode and operating as intended the display will be green. If control is not enabled then the display will be yellow while in an alarm state the display flashes red.\u003c\/p\u003e\n\u003ch5\u003eIntuitive LCD\u003c\/h5\u003e\n\u003cp\u003eBoth ORP (mV) and temperature are displayed with status icons that show when the pump is dosing and the control mode status.\u003c\/p\u003e\n\u003ch5\u003eProgrammable Alarm System\u003c\/h5\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level alarms for ORP. When an alarm is activated,  all dosing will stop. For added safety,  the alarm system also offers overdosing protection in that if the set point value is not corrected within a programmed time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-flow.jpg\" alt=\"flow rate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003ch5\u003eAdjustable Flow Rate\u003c\/h5\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than smaller ones in per unit of time. The adjustable flow rate,  like the proportional band,  allows for better control in maintaining a desired set point .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-proportional.jpg\" alt=\"Automatic Proportional Pump Control\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Proportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe peristaltic dosing pump can be controlled by simple on\/off or more advanced proportional control which helps prevents overshooting of the set point. When using proportional control the flow rate that is programmed,  will be impacted by the proportional band used. The closer the reading is to the set point the longer it takes for the peristaltic pump to complete one revolution. If the reading is outside the proportional band then the amount of time it takes to complete one revolution is based on the flow rate programmed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl-level.jpg\" alt=\" Acid Tank Level\/Flow Switch Input\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOxidation Chemical Tank Level\/Flow Switch Input\u003c\/h4\u003e\n\u003cp\u003eThe BL101 allows for a connection to an optional level controller or flow switch. This input can be used to disable the dosing pump when there is no chemical left in the reservoir tank or there is no flow due to the pump being turned off.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ORP-peristaltic-pump.jpg\" alt=\"Pooline ORP Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Dosing Pump\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eThe BL101 features a peristaltic dosing pump that is superior to diaphragm versions due to the ability to self-prime when there is no liquid in the uptake line. The loss of prime can be problematic with a diaphragm pump due to the gassing of chlorine.\u003c\/p\u003e\n\u003ch4\u003eBrushless Motor\u003c\/h4\u003e\n\u003cp\u003eThe brushless motor does not have any gears or brushes that can wear out. A brushless design provides for a long life and little maintenance. The compact stepper motor allows for very precision control over the dosing of the chemical.\u003c\/p\u003e\n\u003ch4\u003eLong-life Persitaltic Tubing\u003c\/h4\u003e\n\u003cp\u003eThe industrial grade peristaltic tubing is chemical resistant and provides for a relatively long-life. As tubing stretches over time it can be easily replaced. No special tools required.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL100-HI10053_flowcellprobe.jpg\" alt=\"pH probe mounted in flow thorugh cell\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eORP electrode with flow cell\u003c\/h4\u003e\n\u003ch5\u003eThree Configuration Options\u003c\/h5\u003e\n\u003cp\u003eThe BL101 is available in multiple configurations including a meter only,  meter and probe,  and\n a complete package that includes bypass loop\nand panel mounted flow through cell. All models include aspiration tubing with filter and dispensing tubing with injection valve.\u003c\/p\u003e\n\u003ch5\u003eHI10053 ORP\/Temperature Probe\u003c\/h5\u003e\n\u003cp\u003eThe BL101 uses the HI20083 amplified probe that incorporates both ORP and temperature sensors and connects to the controller with a single waterproof Quick Connect DIN connector.\u003c\/p\u003e\n\u003ch5\u003eNPT Threads for In-line and Tank Mounting\u003c\/h5\u003e\n\u003cp\u003eThe ABS body of the probe has a 1\/2” threaded fitting for insertion to an in-line “T” fitting or the flow cell. The back end part of the probe has 3\/4” NPT threads for submersion\/ tank mounting. The probe body has a hex fitting for tightening snuggly with a wrench. .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL101-web\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line ORP Controller and Dosing Pump - BL101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e -2000 to 2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Calibration\u003c\/td\u003e\n\u003ctd\u003e process calibration: single point, adjustable (± 50 mV around measured ORP value)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e High or Low Mode Operation \u003cbr\u003eHigh set point dosing is activated when reading is higher than set point \u003cbr\u003e Low set point dosing is activated when reading is lower than set point (dose oxidizer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e On\/Off control using adjustable set point (200 to 900 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Proportional Band\u003c\/td\u003e\n\u003ctd\u003e adjustable proportional band (10 to 200 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e adjustable hysteresis (10-100 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0 °C (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5 °C (±0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e proportional and on\/off control\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003e triggered after 5 sec. if the controller records a set of consecutive readings over or under threshold values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e overtime protection (1 to 180 m in. or Off)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003e external switches can be connected to hold the control due to external events (low reagent level, recirculation pump doesn't work)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 15 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e wall mounted with built-in pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e selectable flow rate (0.5 to 3.5 L \/ hour; 0.13 to 0.96 g\/hour) \u003cbr\u003emanual control for pump priming\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003e HI20083 ORP\/temperature probe with quick connect DIN connector (supplied)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 100 - 240 Vac, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F), max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 90 x 142 x 80 mm (3.5 x 5.6 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (32 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL101-00 is supplied with BL101 controller, HI20083 ORP\/temperature probe, ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003cbr\u003eBL101-10 is supplied with BL101 controller, HI20083 ORP\/temperature probe, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (5), ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode. BL101-20 is supplied with BL101 controller, HI20083 ORP\/temperature probe, panel mounted flow cell assembly, 50 mm saddle for probe and chemical injector (2), aspiration filter (1), 1\/2” threaded injection valve (1), flexible aspiration PVC tubing (5 m), rigid dispensing PE tubing (15 m), tubing adapter 1\/2” - 6 mm with racord (2), ORP test solution (3 pcs.), power connection cable, instruction manual and quality certificates for the instrument and electrode.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL101-web\"\u003ePool Line ORP Controller and Dosing Pump - BL101\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159746929,"sku":"BL101","price":40702.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl100_front_2ddf55cf-84e8-4a29-ace1-49a0410f5dfb.jpg?v=1792645796"},{"product_id":"swimming-pool-controller-with-built-in-dosing-pumps-bl120","title":"Swimming Pool Controller with Built-in Dosing Pumps - BL120-10","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl121-front.jpg\" alt=\"BL121\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eController Overview\u003c\/h5\u003e\n\u003ch4\u003eMultiple Configurations\u003c\/h4\u003e\n\u003cp\u003eThe controller is available in one of two configurations: an in-line model which allows for direct installation of the probe and chemical injection fittings into existing piping (BL120-10) or a panel mounted system with a bypass flow cell (BL120-20). The bypass flow cell allows for calibration and maintenance of the probe without having to stop the recirculation pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL120-410_FlowCell.jpg\" alt=\"\" width=\"600\" height=\"600\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eDigital Combination Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI1036-1802 is a digital probe that measures pH, ORP, and temperature. This probe also incorporates a potential matching pin. The pin is considered the “earth ground” connection and is used to prevent ground loop effects from causing erratic readings and damage to the system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1036-18_close-up.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121-cords.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eDosing \u0026amp; Control\u003c\/h5\u003e\n\u003ch4\u003ePeristaltic Dosing System\u003c\/h4\u003e\n\u003cp\u003eThe BL120 is equipped with two peristaltic dosing pumps with replaceable chemical resistant tubing. When using a diaphragm pump, chlorine gas formed from outgassing can collect in the pump head resulting in the pump losing its prime; the buildup of chlorine gas is not a problem with peristaltic pumps that use rollers and tubing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eProportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe BL120 features proportionally controlled dosing pumps. Based on the sensitivity of the process to chemical addition, these controllers allow the user to adjust a proportional band. This setting determines the amount of time that the pumps are dosing as a percentage of the deviation from the set point allowing for very fine control in maintaining the desired set point.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Flow Rate\u003c\/h4\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than small bodies since it takes more chemical to realize a change in the reading. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point.\u003c\/p\u003e\n\u003ch4\u003eORP Dosing Consent\u003c\/h4\u003e\n\u003cp\u003eWith chlorine disinfection there is an inverse relationship between pH and ORP. As the pH level increases, the ORP level decreases. The BL120 utilizes a dosing consent feature that will not dose chlorine until the pH value is first corrected since it is possible to have a low ORP value even though there is sufficient chlorine. The dosing consent feature prevents wastage of chemicals and avoids a higher than necessary chlorine concentration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121_Connection.jpg\" alt=\"BL121 Display\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch5 style=\"margin-top: 0;\"\u003eConnections \u0026amp; Display\u003c\/h5\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121-SCREENSHOTS.gif\" alt=\"BL121 Display\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCirculation Pump Monitoring\u003c\/h4\u003e\n\u003cp\u003eAn inline flow switch or a mechanical relay connected to the recirculation pump power source may be connected to the hold input of the BL120. With no flow or when no power is applied to the recirculation pump, the hold circuit disables the dosing pumps. This will prevent any dosing of chemical when there is no movement of water in the system.\u003c\/p\u003e\n\u003ch4\u003eMultifaceted Display\u003c\/h4\u003e\n\u003cp\u003eThe versatile display of the BL121 allows for three screen modes. The LCD can display all three parameters at one time, a 3-second cycle of single parameters, or a real-time plot screen with options for parameter selection, zooming, and log recall.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Alarm System\u003c\/h4\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level of alarms for all parameters. When an alarm is activated, all dosing will stop. The alarm system also offers overdosing protection if the value is not corrected within a specified time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003ch4\u003eMulticolored LED Indicators\u003c\/h4\u003e\n\u003cp\u003eThe BL120 offers multiple LED indicators for status, servicing, and pump operation. The STATUS LED changes color based on operational state; green when setting are in range, yellow when user intervention is required, and red for problems. The SERVICE LED indicates any alarms and process errors experienced by the controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121-USB.jpg\" alt=\"\" width=\"688\" height=\"688\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eCommunication \u0026amp; Security\u003c\/h5\u003e\n\u003ch4\u003eAutomatic Logging\u003c\/h4\u003e\n\u003cp\u003eThe readings for each parameter are automatically logged every 10 seconds. A new log is started each time the instrument is calibrated or at the start of a new day. Logged data include pH, ORP, and temperature values, last calibration data, setup configuration, and any event data. Each log is saved as a .csv file for easy transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eUSB Connectivity\u003c\/h4\u003e\n\u003cp\u003eFor review and storage the users can easily transfer data to a PC using a flash drive and the USB port.\u003c\/p\u003e\n\u003ch4\u003ePassword Protection\u003c\/h4\u003e\n\u003cp\u003eHanna’s BL120 controller features a password protection solution that offers restricted access to calibration, setup, and review of logged data. The password can be set and enabled\/disabled during general setup of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL120-web\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSwimming Pool Controller with Built-in Dosing Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003epH buffer calibration: Automatic, two points (4.01, 7.01, 10.01 pH)\npH process calibration: Single point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic -5.0 to 105.0 ºC (23.0 to 221.0 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0 ºC (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 ºC (±1.8 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003eProportional feed using adjustable set point and adjustable proportional band.\nDelay to start at power-on and overdosing protection using.\nOver feed safety timer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsent Relay\u003c\/td\u003e\n\u003ctd\u003epH dosing interlocked with ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003eHigh and Low with enable\/disable option for all parameters.\nAlarm is triggered for 5 consecutive readings over\/under threshold.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eOver feed safety timer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e(BL122 only - 3) 4 to 20 mA, sourcing, configurable\nOutput impedance ≤ 500 Ohm Accuracy \u0026lt; 0.5 % FS\nGalvanically isolated up to 50 V relative to earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolated, powered contact type\nLow level in acid\/base tank (contact open)\nLow level in chlorine tank (contact open)\nHold input (contact open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-parameter Probe\u003c\/td\u003e\n\u003ctd\u003eHI1036-18XX (02, 05, 10, 15, 20 m of cable) pH\/ORP\/Temperature with matching pin combined digital probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic Log of measurements (pH, ORP, Temperature) and events: alarms, errors, power-failed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e60 days logging with 10 s period (or 100 logs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003epH\/ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 - 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0-50 ºC (32-122 ºF) Max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e245 x 188 x 55 mm (73 mm with pumps)\n9.6 x 7.4 x 2.2” (2.9” with pumps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1700 g (60 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL120-web\" target=\"_blank\" rel=\"noopener\"\u003eSwimming Pool Controller with Built-in Dosing Pumps\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871159779697,"sku":"BL120-10","price":143417.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl121-front_b14d4c47-29ba-409b-995e-31a1fc79b7e0.jpg?v=1792645796"},{"product_id":"swimming-pool-controller-with-built-in-dosing-pumps-analog-outputs-and-in-line-mounting-kit","title":"Swimming Pool Controller with Built-in Dosing Pumps,  Analog Outputs and In-line Mounting Kit - BL121-10","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl121-front.jpg\" alt=\"HI902C Angled\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eController Overview\u003c\/h5\u003e\n\u003ch4\u003eMultiple Configurations\u003c\/h4\u003e\n\u003cp\u003eThe controller is available in one of two configurations: an in-line model which allows for direct installation of the probe and chemical injection fittings into existing piping (BL120-10) or a panel mounted system with a bypass flow cell (BL120-20). The bypass\nflow cell allows for calibration and maintenance of the probe without having to stop the recirculation pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL120-410_FlowCell.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eDigital Combination Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI1036-1802 is a digital probe that measures pH, ORP, and temperature. This probe also incorporates a\npotential matching pin. The pin is considered the “earth ground” connection and is used to prevent ground loop effects from causing\nerratic readings and damage to the system.\u003c\/p\u003e\n\u003ch5\u003eDosing \u0026amp; Control\u003c\/h5\u003e\n\u003ch4\u003ePeristaltic Dosing System\u003c\/h4\u003e\n\u003cp\u003eThe BL120 is equipped with two peristaltic dosing pumps with replaceable chemical resistant tubing. When using a diaphragm pump,\u003cbr\u003e\nchlorine gas formed from outgassing can collect in the pump head resulting in the pump losing its prime; the buildup of chlorine gas is\u003cbr\u003e\nnot a problem with peristaltic pumps that use rollers and tubing.\u003c\/p\u003e\n\u003ch4\u003eProportional Pump Control\u003c\/h4\u003e\n\u003cp\u003eThe BL120 features proportionally controlled dosing pumps. Based on the sensitivity of the process to chemical addition, these controllers\u003cbr\u003e\nallow the user to adjust a proportional band. This setting determines the amount of time that the pumps are dosing as a percentage of the\u003cbr\u003e\ndeviation from the set point allowing for very fine control in maintaining the desired set point.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Flow Rate\u003c\/h4\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than\u003cbr\u003e\nsmall bodies since it takes more chemical to realize a change in the reading. The adjustable flow rate, like the proportional band, allows\u003cbr\u003e\nfor better control in maintaining a desired set point.\u003c\/p\u003e\n\u003ch4\u003eORP Dosing Consent\u003c\/h4\u003e\n\u003cp\u003eWith chlorine disinfection there is an inverse relationship between pH and ORP. As the pH level increases, the ORP level decreases. The\u003cbr\u003e\nBL120 utilizes a dosing consent feature that will not dose chlorine until the pH value is first corrected since it is possible to have a\u003cbr\u003e\nlow ORP value even though there is sufficient chlorine. The dosing consent feature prevents wastage of chemicals and avoids a higher than\u003cbr\u003e\nnecessary chlorine concentration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121-SCREENSHOTS.gif\" alt=\"BL121 Display\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eConnections \u0026amp; Display\u003c\/h5\u003e\n\u003ch4\u003eCirculation Pump Monitoring\u003c\/h4\u003e\n\u003cp\u003eAn inline flow switch or a mechanical relay connected to the recirculation pump power source\nmay be connected to the hold input of the BL120. With no flow or when no power is applied to the recirculation pump, the hold\ncircuit disables the dosing pumps. This will prevent any dosing of chemical when there is no movement of water in the system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMultifaceted Display\u003c\/h4\u003e\n\u003cp\u003eThe versatile display of the BL121 allows for three screen modes. The LCD can display all three parameters at one time, a 3-second cycle of single parameters, or a real-time plot screen with options for parameter selection, zooming, and log recall.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Alarm System\u003c\/h4\u003e\n\u003cp\u003eHanna controllers allow users to\nenable or disable the low and high level of alarms for all\nparameters. When an alarm is activated, all dosing will stop.\nThe alarm system also offers overdosing protection if the value\nis not corrected within a specified time interval then the\nmeter will go into alarm status.\u003c\/p\u003e\n\u003ch4\u003eMulticolored LED Indicators\u003c\/h4\u003e\n\u003cp\u003eThe BL120 offers multiple LED\nindicators for status, servicing, and pump operation. The\nSTATUS LED changes color based on operational state; green when\nsetting are in range, yellow when user intervention is\nrequired, and red for problems. The SERVICE LED indicates any\nalarms and process errors experienced by the controller.\u003c\/p\u003e\n\u003ch5\u003eCommunication \u0026amp; Security\u003c\/h5\u003e\n\u003ch4\u003eAutomatic Logging\u003c\/h4\u003e\n\u003cp\u003eThe readings for each parameter are automatically logged every\u003cbr\u003e\n10 seconds. A new log is started each time the instrument is\u003cbr\u003e\ncalibrated or at the start of a new day. Logged data include pH,\u003cbr\u003e\nORP, and temperature values, last calibration data, setup\u003cbr\u003e\nconfiguration, and any event data. Each log is saved as a .csv file\u003cbr\u003e\nfor easy transfer.\u003c\/p\u003e\n\u003ch4\u003eUSB Connectivity\u003c\/h4\u003e\n\u003cp\u003eFor review and storage the users can easily transfer data to a\u003cbr\u003e\nPC using a flash drive and the USB port.\u003c\/p\u003e\n\u003ch4\u003ePassword Protection\u003c\/h4\u003e\n\u003cp\u003eHanna’s BL120 controller features a password protection solution\u003cbr\u003e\nthat offers restricted access to calibration, setup, and review of\u003cbr\u003e\nlogged data. The password can be set and enabled\/disabled during\u003cbr\u003e\ngeneral setup of the instrument.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL121-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSwimming Pool Controller with Built-in Dosing Pumps, Analog Outputs and In-line Mounting Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003epH buffer calibration: Automatic, two points (4.01, 7.01, 10.01 pH)\npH process calibration: Single point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic -5.0 to 105.0 ºC (23.0 to 221.0 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0 ºC (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 ºC (±1.8 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003eProportional feed using adjustable set point and adjustable proportional band.\nDelay to start at power-on and overdosing protection using.\nOver feed safety timer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsent Relay\u003c\/td\u003e\n\u003ctd\u003epH dosing interlocked with ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003eHigh and Low with enable\/disable option for all parameters.\nAlarm is triggered for 5 consecutive readings over\/under threshold.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eOver feed safety timer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e(BL122 only - 3) 4 to 20 mA, sourcing, configurable\nOutput impedance ≤ 500 Ohm Accuracy \u0026lt; 0.5 % FS\nGalvanically isolated up to 50 V relative to earth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolated, powered contact type\nLow level in acid\/base tank (contact open)\nLow level in chlorine tank (contact open)\nHold input (contact open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-parameter Probe\u003c\/td\u003e\n\u003ctd\u003eHI1036-18XX (02, 05, 10, 15, 20 m of cable) pH\/ORP\/Temperature with matching pin combined digital probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic Log of measurements (pH, ORP, Temperature) and events: alarms, errors, power-failed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e60 days logging with 10 s period (or 100 logs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003epH\/ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 - 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0-50 ºC (32-122 ºF) Max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e245 x 188 x 55 mm (73 mm with pumps)\n9.6 x 7.4 x 2.2” (2.9” with pumps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1700 g (60 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL121-10\" target=\"_blank\" rel=\"noopener\"\u003eSwimming Pool Controller with Built-in Dosing Pumps, Analog Outputs and In-line Mounting Kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162007921,"sku":"BL121-10","price":160555.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl121-front_ccb6b8f6-663d-466f-ab9a-2fac766aa4ce.jpg?v=1792645797"},{"product_id":"cloud-enabled-swimming-pool-controller-with-built-in-dosing-pumps-bl122","title":"Cloud Enabled Swimming Pool Controller with Built-in Dosing Pumps - BL122-10","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL122_front_Probe.jpg\" alt=\"Pool Line Cloud pH\/ORP Controller\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe chlorine level is measured based on the ORP or REDOX principle. An increase of the ORP value correlates with an increase of the free chlorine level. pH and disinfectant testings are made together for more efficient disinfection and control. The efficacy of sanitizers, is dependent on a controlled pH value. The ORP value is the most consistent indicator of the sanitizing effectiveness of the pool\/hot tub or water treatment. Typically 650-750 mV at 7.2 pH indicates proper water treatment (all harmful bacteria are killed in matter of seconds). pH and disinfectant testings are made using the HI1036-1802 combined electrode installed inline or in flow cell. To prevent the ground loop effects from causing erratic readings and damage to the system the electrode has a matching pin considered the “earth ground“ connection. The greatest detectives were specially designed to detect the broken electrode based on a shifted ISO potential value. The HI1036-1802 uses a Ag\/AgCl reference with 3.5 M KCl. The ORP values are referenced to it.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Hanna_Cloud_App.jpg\" alt=\"hannacloud.com\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eRemote Access with Most Browsers\u003c\/h4\u003e\n\u003ch4\u003ehannacloud.com\u003c\/h4\u003e\n\u003cp\u003eHanna Cloud is a web based application that connects you to measurement devices such as the BL122 and BL123. Measurements and data storage are accessible from your PC, tablet or phone. Multiple registered devices may be connected to Hanna Cloud.\u003c\/p\u003e\n\u003cp\u003eMeasurements, trends, history, device settings, alarms and messages are transmitted to your “Dashboard” as your instrument measures and controls your process.\u003c\/p\u003e\n\u003cp\u003eMultiple secondary users may also be added to your device account to monitor measurements and receive email or pop-up messages from your process device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Pool_controller_measurment.jpg\" alt=\" Pool Controller Measurement \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHanna Cloud Features\u003c\/h4\u003e\n\u003ch5\u003eMeasurement\u003c\/h5\u003e\n\u003cp\u003eMeasurement, alarm, hold and pump status are easily viewable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Pool_contorller_notifications.jpg\" alt=\"Pool Controller Notifications\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eNotifications\u003c\/h4\u003e\n\u003cp\u003eSelect which notifications you would like to receive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Pool-Controller-GLP.jpg\" alt=\"GLP Data\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP\u003c\/h4\u003e\n\u003cp\u003eReview of GLP data including date and time of the last calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Pool_controller_logging.jpg\" alt=\" Pool Controller Logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLogging\u003c\/h4\u003e\n\u003cp\u003eLog history in table form. Can be transferred as a PDF or csv.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Pool-Controller-Graphing.jpg\" alt=\"Pool Controller Graphing\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGraphing\u003c\/h4\u003e\n\u003cp\u003eUse a graph to view trends over the last 12 hours or change to a specific time period.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121-cords.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eDosing \u0026amp; Control\u003c\/h4\u003e\n\u003ch4\u003ePeristaltic Dosing System\u003c\/h4\u003e\n\u003cp\u003eThe BL122 and BL123 are equipped with two peristaltic dosing pumps with replaceable chemical resistant tubing. When using a diaphragm pump, chlorine gas formed from outgassing can collect in the pump head resulting in the pump losing its prime; the buildup of chlorine gas is not a problem with peristaltic pumps that use rollers and tubing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eProportional Pump Control\u003c\/h4\u003e\n\u003cp\u003ePool LIne controllers feature proportionally controlled dosing pumps. Based on the sensitivity of the process to chemical addition, these controllers allow the user to adjust a proportional band. This setting determines the amount of time that the pumps are dosing as a percentage of the deviation from the set point allowing for very fine control in maintaining the desired set point.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Flow Rate\u003c\/h4\u003e\n\u003cp\u003eThe flow rate from the dosing pumps is adjustable from 0.5 to 3.5L\/h. Larger bodies of water require more chemical to be dosed than small bodies since it takes more chemical to realize a change in the reading. The adjustable flow rate, like the proportional band, allows for better control in maintaining a desired set point.\u003c\/p\u003e\n\u003ch4\u003eORP Dosing Consent\u003c\/h4\u003e\n\u003cp\u003eWith chlorine disinfection there is an inverse relationship between pH and ORP. As the pH level increases, the ORP level decreases. The BL120 utilizes a dosing consent feature that will not dose chlorine until the pH value is first corrected since it is possible to have a low ORP value even though there is sufficient chlorine. The dosing consent feature prevents wastage of chemicals and avoids a higher than necessary chlorine concentration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL122-Ethernet-Connection.jpg\" alt=\"Pool Line Controller Connections\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch5 style=\"margin-top: 0;\"\u003eConnections \u0026amp; Display\u003c\/h5\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121-SCREENSHOTS.gif\" alt=\"Pool Line Controller Display\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eCirculation Pump Monitoring\u003c\/h4\u003e\n\u003cp\u003eAn inline flow switch or a mechanical relay connected to the re-circulation pump power source may be connected to the hold input of the Pool Line controller. With no flow or when no power is applied to the re-circulation pump, the hold circuit disables the dosing pumps. This will prevent any dosing of chemical when there is no movement of water in the system.\u003c\/p\u003e\n\u003ch4\u003eMultifaceted Display\u003c\/h4\u003e\n\u003cp\u003eThe versatile display of the BL122 and BL123 allows for three screen modes. The LCD can display all three parameters at one time, a 3-second cycle of single parameters, or a real-time plot screen with options for parameter selection, zooming, and log recall.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Alarm System\u003c\/h4\u003e\n\u003cp\u003eHanna controllers allow users to enable or disable the low and high level of alarms for all parameters. When an alarm is activated, all dosing will stop. The alarm system also offers overdosing protection if the value is not corrected within a specified time interval then the meter will go into alarm status.\u003c\/p\u003e\n\u003ch4\u003eMulticolored LED Indicators\u003c\/h4\u003e\n\u003cp\u003eThe Pool LIne cloud controllers offer multiple LED indicators for status, servicing, and pump operation. The STATUS LED changes color based on operational state; green when setting are in range, yellow when user intervention is required, and red for problems. The SERVICE LED indicates any alarms and process errors experienced by the controller.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL121-USB.jpg\" alt=\"\" width=\"688\" height=\"688\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eCommunication \u0026amp; Security\u003c\/h5\u003e\n\u003ch4\u003eAutomatic Logging\u003c\/h4\u003e\n\u003cp\u003eThe readings for each parameter are automatically logged every 10 seconds. A new log is started each time the instrument is calibrated or at the start of a new day. Logged data include pH, ORP, and temperature values, last calibration data, setup configuration, and any event data. Each log is saved as a .csv file for easy transfer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eUSB Connectivity\u003c\/h4\u003e\n\u003cp\u003eFor review and storage the users can easily transfer data to a PC using a flash drive and the USB port.\u003c\/p\u003e\n\u003ch4\u003ePassword Protection\u003c\/h4\u003e\n\u003cp\u003eHanna’s BL122 and BL123 controllers feature a password protection solution that offers restricted access to calibration, setup, and review of logged data. The password can be set and enabled\/disabled during general setup of the instrument.\u003c\/p\u003e\n\u003ch4\u003eMultiple Configurations\u003c\/h4\u003e\n\u003cp\u003eThe controller is available in one of two configurations: an in-line model which allows for direct installation of the probe and chemical injection fittings into existing piping (BL122-10 \u0026amp; BL123-10) or a panel mounted system with a bypass flow cell (BL122-20 \u0026amp; BL123-20). The bypass flow cell allows for calibration and maintenance of the probe without having to stop the recirculation pump.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Pool_Line_Flow_Cell.jpg\" alt=\"\" width=\"600\" height=\"600\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eDigital Combination Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI1036-1802 is a digital probe that measures pH, ORP, and temperature. This probe also incorporates a potential matching pin. The pin is considered the “earth ground” connection and is used to prevent ground loop effects from causing erratic readings and damage to the system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1036-18_close-up.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL122-web\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCloud Enabled Swimming Pool Controller with Built-in Dosing Pumps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003epH buffer calibration: Automatic, two points (4.01, 7.01, 10.01 pH)\npH process calibration: Single point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic -5.0 to 105.0 ºC (23.0 to 221.0 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105.0 ºC (23.0 to 221.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 ºC (±1.8 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003eProportional feed using adjustable set point and adjustable proportional band.\nDelay to start at power-on and overdosing protection using.\nOver feed safety timer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConsent Relay\u003c\/td\u003e\n\u003ctd\u003epH dosing interlocked with ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003eHigh and Low with enable\/disable option for all parameters.\nAlarm is triggered for 5 consecutive readings over\/under threshold.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eOver feed safety timer.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e4 to 20 mA (3), sourcing, configurable\nOutput impedance ≤ 500 Ohm Accuracy \u0026lt; 0.5 % FS\nGalvanically isolated up to 50 V relative to earth\nAnalog outputs only available with BL123-10 and BL123-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003eGalvanic isolated, powered contact type\nLow level in acid\/base tank (contact open)\nLow level in chlorine tank (contact open)\nHold input (contact open)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e10 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMulti-parameter Probe\u003c\/td\u003e\n\u003ctd\u003eHI1036-18XX (02, 05, 10, 15, 20 m of cable) pH\/ORP\/Temperature with matching pin combined digital probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic Log of measurements (pH, ORP, Temperature) and events: alarms, errors, power-failed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e60 days logging with 10 s period (or 100 logs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003epH\/ORP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 - 240 VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0-50 ºC (32-122 ºF) Max 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e245 x 188 x 55 mm (73 mm with pumps)\n9.6 x 7.4 x 2.2” (2.9” with pumps)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1700 g (60 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003e\u003cstrong\u003eIn-Line Configuration\u003c\/strong\u003eBL122-10 pH\/ORP\/temperature pool controller is supplied with HI1036-1802 pH\/ORP\/ temperature digital probe with matching pin, 50 mm probe saddle (1), fitting for probe, chemical injectors (2), 50 mm saddle for injectors (2), peristaltic pump tubing (2), 5 m of injection tubing, aspiration filter (2), aspiration filter weight, pH 7.01 buffer sachets, 20mL (3), pH 4.01 buffer sachets, 20mL (3), 470 mV test solution sachets (3), power cable and instruction manual. *CAL injectors (2), 50 mm saddle for injectors (2), peristaltic pump tubing (2), 5 m of injection tubing, aspiration filter (2), aspiration filter weight, pH 7.01 buffer sachets, 20mL (3), pH 4.01 buffer sachets, 20mL (3), 470 mV test solution sachets (3), power cable and instruction manual. \u003cstrong\u003eFlow Cell Panel Mounted Configuration\u003c\/strong\u003eBL122-20 pH\/ORP\/temperature pool controller with flow cell is supplied with panel mounted flow cell, HI1036-1802 pH\/ORP\/temperature digital probe with matching pin, Two valves for flow-cell connections with fittings and tubing (10 m), injector (2), 50mm saddle for injectors (2), 50 mm saddle for valves (2), peristaltic pump tubing (2), suction and injection tubing (10 m), 5 m of injection tubing, aspiration filter (2), aspiration filter weight (2), pH 7.01 buffer sachets, 20mL (3), pH 4.01 buffer sachets, 20mL (3), 470 mV test solution sachets (3), power cable and instruction manual. BL123-20 pH\/ORP\/temperature pool controller with flow cell and analog output is supplied with panel mounted flow cell, HI1036-1802 pH\/ORP\/temperature digital probe with matching pin, Two valves for flow-cell connections with fittings and tubing (10 m), injector (2), 50mm saddle for injectors (2), 50 mm saddle for valves (2), peristaltic pump tubing (2), suction and injection tubing (10 m), 5 m of injection tubing, aspiration filter (2), aspiration filter weight (2), pH 7.01 buffer sachets, 20mL (3), pH 4.01 buffer sachets, 20mL (3), 470 mV test solution sachets (3), power cable and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL122-web\" target=\"_blank\" rel=\"noopener\"\u003eCloud Enabled Swimming Pool Controller with Built-in Dosing Pumps\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162138993,"sku":"BL122-10","price":197606.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl121-usb-cover-off_2_1.jpg?v=1792645798"},{"product_id":"pool-line-calibration-and-maintenance-kit-bl123-70-30","title":"Pool Line Calibration and Maintenance Kit – BL123-70-30","description":"\u003cp\u003eEl Kit de Mantenimiento y Calibración Línea Piscina BL123-70-30 contiene:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e30 Sobres de Solución Estándar pH 7.01 (20 mL)\u003c\/li\u003e\n\u003cli\u003e30 Sobres de Solución Estándar pH 4.01 (20 mL)\u003c\/li\u003e\n\u003cli\u003e30 Sobres de Solución de Limpieza de Electrodos (20 mL)\u003c\/li\u003e\n\u003cli\u003e30 Sobres de Solución de Almacenamiento de Electrodos (20 mL)\u003c\/li\u003e\n\u003cli\u003e30 Sobres de Solución de Prueba de ORP (20 mL)\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162171761,"sku":"BL123-70-30","price":24308.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl123-70-556x720-b3dea297-e195-43a3-8c12-6c2eb47ffb5c_1.png?v=1792645798"},{"product_id":"pool-line-bleach-test-kit-hi38434","title":"Pool Line Bleach Test Kit - HI38434","description":"\u003cp\u003eSodium hypochlorite (bleach) is a commonly used disinfectant for swimming pools, spas and hot tubs. Bleach purchased for disinfection will usually contain 100 to 150 g\/L (10 to 15%) of chlorine. The concentration of bleach will degrade and lose its strength during storage. For bodies of water that are continuously monitored and controlled with process instrumentation this change in concentration can cause issues with instrument settings. Control parameters are set based on the strength of the chemical being dosed. For this reason it is important to monitor the concentration of chlorine that is being purchased for the automatic dosing into the swimming pool, hot tub or spa.\u003c\/p\u003e\n\u003cp\u003eAvailable chlorine refers to chlorine liberated by the action of dilute acids on hypochlorite:\u003c\/p\u003e\n\u003cp\u003eOCl\u003csup\u003e-\u003c\/sup\u003e + Cl\u003csup\u003e-\u003c\/sup\u003e + 2H\u003csup\u003e+\u003c\/sup\u003e = Cl\u003csub\u003e2\u003c\/sub\u003e + H\u003csub\u003e2\u003c\/sub\u003eO\u003c\/p\u003e\n\u003cp\u003eHI38434 uses an iodometric titration method. First,  the hypochlorite solution is treated with potassium iodide and acidified with a strong acid. The amount of iodine generated is equivalent to the chlorine in the sample. The next step is to determine the concentration of iodine by the titration with thiosulfate to reduce the iodine back to iodide ions. The amount of thiosulfate added is then used to calculate the amount of chlorine that was in the original sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI38434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Bleach Test Kit - HI38434\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHypochlorite Measurement Type\u003c\/td\u003e\n\u003ctd\u003e chemical test kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHypochlorite Range\u003c\/td\u003e\n\u003ctd\u003e 50 to 150 g\/L (5 to 15%) Chlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHypochlorite Resolution\u003c\/td\u003e\n\u003ctd\u003e 5 g\/L (0.5%) as Chlorine (Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHypochlorite Method\u003c\/td\u003e\n\u003ctd\u003e iodometric titration method \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHypochlorite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100 (average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 485 g (17.1 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 235 x 175 x 115 mm (9.2 x 6.9 x 4.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI38434\"\u003ePool Line Bleach Test Kit - HI38434\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871271944561,"sku":"HI38434","price":10707.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi38434_1.jpg?v=1792646007"},{"product_id":"swimming-pool-chemical-test-kit-hi3887","title":"Swimming Pool Chemical Test Kit - HI3887","description":"\u003cp\u003eThe HI3887 is a colorimetric chemical test kit that determines the free chlorine concentration and pH level in samples within a 0.0 to 2.5 mg\/L (ppm) Cl\u003csup\u003e-\u003c\/sup\u003erange and 6.0 to 8.5 pH range. The HI3887 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 50 tests for free chlorine and 100 tests for pH.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the color comparison cubes and reagent dropper bottles.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eFree chlorine readings from 0.0 to 2.5 mg\/L are determined to 0.5 mg\/L resolution.\u003c\/li\u003e\n\u003cli\u003epH readings from 6.0 to 8.5 pH are determined to 0.5 pH resolution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eChlorine is one of the most commonly used disinfectants for drinking water, wastewater, and water used for pools and spas. It can be added to in various forms including calcium hypochlorite, sodium hypochlorite, or in some instances, chlorine gas. When added to water, chlorine creates hypochlorous acid (HOCl) which dissociates into hypochlorite ion (OCl\u003csup\u003e-\u003c\/sup\u003e).\u003c\/p\u003e\n\u003cp\u003eHOCl ↔ H\u003csup\u003e+\u003c\/sup\u003e + OCl\u003csup\u003e-\u003c\/sup\u003e\u003cbr\u003e\nhypochlorous acid ↔ hydrogen ion + hypochlorite ion\u003c\/p\u003e\n\u003cp\u003eHOCl is the form of chlorine that acts as a stronger disinfectant as compared to OCl\u003csup\u003e-\u003c\/sup\u003e. To ensure the added chlorine is effective at sanitizing, the pH of the water must be taken into account. Around pH 7.5, HOCl and OCl\u003csup\u003e-\u003c\/sup\u003e are present in relatively equal amounts. Below pH 7.5, the equilibrium shifts to favor HOCl; above pH 7.5, the equilibrium shifts to favor OCl\u003csup\u003e-\u003c\/sup\u003e. Depending on the application, addition of chlorine is effective when added to water with a neutral or slightly acidic pH value.\u003c\/p\u003e\n\u003cp\u003eWhen chlorine is first added to water, it is available as free chlorine. The measurement of free chlorine signifies the amount available for disinfection. Once chlorine begins to sanitize bacteria and pathogens present in the water, it becomes combined chlorine; combined chlorine is no longer available to act as a disinfectant.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3887\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSwimming Pool Chemical Test Kit - HI3887\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e6.0 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003epH indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 2.5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Number of Tests\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eDPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3887 test kit comes with color comparison cubes (2), 20 mL reagent 1, 15 mL reagent 2, 25 mL HI 3881-0 pH 6.0-8.5 reagent.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3887\" target=\"_blank\" rel=\"noopener\"\u003eSwimming Pool Chemical Test Kit - HI3887\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871274991985,"sku":"HI3887","price":5835.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3887_2017.jpg?v=1792646021"},{"product_id":"pool-line-quick-total-hardness-chemical-test-kit-hi38904","title":"Pool Line Quick Total Hardness Chemical Test Kit - HI38904","description":"\u003cp\u003eWater hardness, especially as calcium, is an important parameter along with pH and alkalinity in maintaining the water chemistry of a swimming pool or hot tub. Water hardness includes both calcium and magnesium ions that are found naturally in water and will vary in concentration based on region and water source. Water sources include lakes, rivers, streams, and groundwater (wells) with groundwater typically being the highest since minerals are picked up by rainwater as it percolates through the soil. For examples in areas with a lot of limestone the groundwater will be high in calcium carbonate.\u003c\/p\u003e\n\u003cp\u003eHardness is an important measurement since if the levels are high the calcium carbonate is likely to precipitate, especially as the pH increases, will lead to cloudy water, clogged filters, and heater inefficiency. If hardness is low then the pool water will attack with calcium carbonate (lime) that is used in grout and concrete leading to pitting and etching.\u003c\/p\u003e\n\u003cp\u003eThe HI38904 is a titration-based chemical test kit that determines the total hardness concentration within the 0 to 800 ppm (mg\/L) range. The HI38904 is supplied with all of the necessary reagents and equipment to perform the analysis for total hardness.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the sample beaker and reagent dropper bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eReadings from 0 to 800 ppm (mg\/L) are determined with a 10 ppm (mg\/L) resolution.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"200\"\u003e \u003ccol width=\"200\"\u003e \u003ccol width=\"200\"\u003e \u003ccol width=\"200\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eHardness Level\u003c\/th\u003e\n\u003cth\u003e℉H\u003c\/th\u003e\n\u003cth\u003e°dH\u003c\/th\u003e\n\u003cth\u003eppm (mg\/L)\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVery Soft\u003c\/td\u003e\n\u003ctd\u003e0 - 7\u003c\/td\u003e\n\u003ctd\u003e0 - 4\u003c\/td\u003e\n\u003ctd\u003e0 - 70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSoft\u003c\/td\u003e\n\u003ctd\u003e7 - 15\u003c\/td\u003e\n\u003ctd\u003e4 - 8\u003c\/td\u003e\n\u003ctd\u003e70 - 150\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSlightly Hard\u003c\/td\u003e\n\u003ctd\u003e15 – 25\u003c\/td\u003e\n\u003ctd\u003e8 - 14\u003c\/td\u003e\n\u003ctd\u003e150 - 250\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMedium Hard\u003c\/td\u003e\n\u003ctd\u003e25-32\u003c\/td\u003e\n\u003ctd\u003e14 - 18\u003c\/td\u003e\n\u003ctd\u003e250 - 320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHard\u003c\/td\u003e\n\u003ctd\u003e32 - 42\u003c\/td\u003e\n\u003ctd\u003e18 - 23\u003c\/td\u003e\n\u003ctd\u003e320 - 420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eVery Hard\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;42\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;23\u003c\/td\u003e\n\u003ctd\u003e\u0026gt;420\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003e1 TH = 1 ℉H = 0.562 °dH = 0.2 meq\/L = 10 ppm (mg\/L) CaCO\u003csub\u003e3\u003c\/sub\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI38904\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Quick Total Hardness Chemical Test Kit - HI38904\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 TH\n0 to 800 ppm (mg\/L) CaCO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e1 TH\n10 ppm (mg\/L) CaCO3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eDrop-count titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI38904 Hardness Chemical Test Kit is supplied with 30 mL hardness buffer, 10 mL calmagite indicator, and 50 mL plastic beaker with cap.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI38904\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Quick Total Hardness Chemical Test Kit - HI38904\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871275057521,"sku":"HI38904","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi38904-1.jpg?v=1792646023"},{"product_id":"pool-line-ph-4-01-buffer-sachets-25-x-20-ml-hi700044p","title":"Pool Line pH 4.01 Buffer Sachets (25 x 20 mL) - HI700044P","description":"\u003cp\u003eHI700044P is a high-quality pH 4.01 calibration buffer produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature-controlled environment monitored with certified thermometers. Reported values are accurate to ±0.02 pH @ 25℃ and are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch4\u003eConvenience of individual packaging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for users that do not calibrate frequently\u003c\/li\u003e\n\u003cli\u003eEvery pH buffer sachet is as fresh as the day it was packaged\u003c\/li\u003e\n\u003cli\u003eLight block packaging prevents oxidation from UV light that could alter the buffer value\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEach sachet marked with lot number and expiration date.\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI700044P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line pH 4.01 Buffer Sachets (25 x 20 mL) - HI700044P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e calibration buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 4.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI700044P\"\u003ePool Line pH 4.01 Buffer Sachets (25 x 20 mL) - HI700044P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871326503281,"sku":"HI700044P","price":3796.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi700044_box.jpg?v=1792646164"},{"product_id":"pool-line-ph-7-01-buffer-sachets-hi700074p","title":"Pool Line pH 7.01 Buffer Sachets - HI700074P","description":"\u003cp\u003eHI700074P is a high-quality pH 7.01 calibration buffer produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature-controlled environment monitored with certified thermometers. Reported values are accurate to ±0.02 pH @ 25℃ and are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch4\u003eConvenience of individual packaging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for users that do not calibrate frequently\u003c\/li\u003e\n\u003cli\u003eEvery pH buffer sachet is as fresh as the day it was packaged\u003c\/li\u003e\n\u003cli\u003eLight block packaging prevents oxidation from UV light that could alter the buffer value\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEach sachet marked with lot number and expiration date.\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI700074P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line pH 7.01 Buffer Sachets - HI700074P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e calibration buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 7.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI700074P\"\u003ePool Line pH 7.01 Buffer Sachets - HI700074P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871326568817,"sku":"HI700074P","price":3796.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi700074_box.jpg?v=1792646165"},{"product_id":"pool-line-470-mv-orp-test-solution-25-x-20-ml-hi700224p","title":"Pool Line 470 mV ORP Test Solution (25 x 20 mL) - HI700224P","description":"\u003cp\u003eHI700224P is an ORP test solution designed for testing the performance of ORP electrodes. When the ORP electrode is placed in the test solution the reading obtained should be close to the 470 mV value. This solution allows users to quickly see if their electrodes are reading correctly. Using this as a diagnostic tool,  users can then decide if the ORP electrode needs to be cleaned,  polished,  and conditioned or replaced. The test solutions are produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eConvenience of individual packaging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for Service Technicians that perform routine probe maintenance\u003c\/li\u003e\n\u003cli\u003eEach sachet is as fresh as the day it was packaged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEach sachet marked with lot number and expiration date\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna ORP test solution is specially formulated to have an expiration of 5 years from the date the solution was packaged.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI700224P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line 470 mV ORP Test Solution (25 x 20 mL) - HI700224P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e ORP test solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 470 mV ±10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI700224P\"\u003ePool Line 470 mV ORP Test Solution (25 x 20 mL) - HI700224P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871330402673,"sku":"HI700224P","price":3796.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi700224_box.jpg?v=1792646167"},{"product_id":"pool-line-electrode-storage-solution-25-x-20-ml-hi7003004p","title":"Pool Line Electrode Storage Solution (25 x 20 mL) - HI7003004P","description":"\u003cp\u003eHI7003004P Pool Line Electrode Storage Solution is a specially formulated storage solution for the proper maintenance of pH and ORP probes when not in use. To optimize the response time it is important to keep the pH bulb hydrated. It is also important to keep the junction of both pH and ORP probes. All electrodes have a junction that is an electrical pathway between the solution tested and an inner electrode. Keeping this junction hydrated keeps the junction free flowing,  which provides for faster and more stable readings.\u003c\/p\u003e\n\u003cp\u003eFor process probes the HI7003004P should also be used to rehydrate the electrode after cleaning the oils and lotions that will coat the sensors over time. After using a cleaning solution the probe should be allowed to soak for 15 minutes to allow for the hydration layer to form. After that time then the a calibration should be performed.\u003c\/p\u003e\n\u003cp\u003eA well-maintained swimming pool,  hot tub,  or spa starts with accurate readings and the proper storage of a pH\/ORP electrode is required to ensure maximum performance and long life.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance\u003c\/h4\u003e\n\u003ch5\u003eConvenience of individual packaging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for Service Technicians that perform routine probe maintenance\u003c\/li\u003e\n\u003cli\u003eEach sachet is as fresh as the day it was packaged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eEach sachet marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna pH and ORP storage solutions are specially formulated to have an expiration of 5 years from the date the solution was packaged.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7003004P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Electrode Storage Solution (25 x 20 mL) - HI7003004P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Electrode storage solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7003004P\"\u003ePool Line Electrode Storage Solution (25 x 20 mL) - HI7003004P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871333056881,"sku":"HI7003004P","price":3796.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7003004_box.jpg?v=1792646175"},{"product_id":"pool-line-general-purpose-cleaning-solution-20-ml-x-25-sachets-hi7006014p","title":"Pool Line General Purpose Cleaning Solution (20 mL x 25 Sachets) - HI7006014P","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note,  because during calibration,  the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. The pH meters on the market today will allow an offset voltage (pH 7.01) of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated then any changes to the probe will result in inaccurate readings.\u003c\/p\u003e\n\u003cp\u003eCleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the sachet containing the cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.\u003c\/p\u003e\n\u003cp\u003eAfter any cleaning procedure is performed it is important to rehydrate the glass of a pH electrode by placing in storage solution for 15 minutes. After the probe is rehydrated then a calibration must be performed. This is very important for process probes since many are used to monitor and control the dosing of chemicals. It is critical that the probe is clean and calibrated in order for a meter to maintain the ideal set point. The cleaning of pH and ORP process probes should be part of a routine maintenance program.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-01-08_at_3.20.38_PM.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eLight block foil packaging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eLight-tight packet helps to prevent against degradation by UV light\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne-time use sachet packets\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach sachet marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7006014P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line General Purpose Cleaning Solution (20 mL x 25 Sachets) - HI7006014P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e General purpose cleaning solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7006014P\"\u003ePool Line General Purpose Cleaning Solution (20 mL x 25 Sachets) - HI7006014P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871338103153,"sku":"HI7006014P","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7006014_box.jpg?v=1792646189"},{"product_id":"pool-line-470-mv-orp-test-solution-500-ml-hi70224l","title":"Pool Line 470 mV ORP Test Solution (500 mL) - HI70224L","description":"\u003cp\u003eOxidation-reduction is a process by which a molecule or ion loses or gains electrons. This occurs most readily in swimming pool, hot tubs, and spas where an oxidizer, such as chlorine, is added to the water to destroy contaminants. The higher the ORP value, the greater the sanitizing power of the water.\u003c\/p\u003e\n\u003cp\u003eHI70224L is an ORP test solution designed for testing the performance of ORP electrodes. When the ORP electrode is placed in the test solution the reading obtained should be close to the 470 mV value. This solution allows users to quickly see if their electrodes are reading correctly. Using this as a diagnostic tool, users can then decide if the ORP electrode needs to be cleaned, polished, and conditioned. Test solutions are produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eThe HI70224L bottle is labeled with:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAir tight bottle with tamper-proof seal\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI70224L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line 470 mV ORP Test Solution (500 mL) - HI70224L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003eORP test solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e470 mV ±10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eBottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI70224L\" target=\"_blank\" rel=\"noopener\"\u003ePool Line 470 mV ORP Test Solution (500 mL) - HI70224L\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871349768561,"sku":"HI70224L","price":3569.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70224l-720x720-2a.jpg?v=1792646214"},{"product_id":"pool-line-general-purpose-cleaning-solution-500-ml-hi70614l","title":"Pool Line General Purpose Cleaning Solution (500 mL) - HI70614L","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note,  because during calibration,  the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. The pH meters on the market today will allow an offset voltage (pH 7.01) of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated then any changes to the probe will result in inaccurate readings.\u003c\/p\u003e\n\u003cp\u003eCleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI70614L cleaning solution for 15 to 20 minutes will dissolve any mineral deposits or other coatings.\u003c\/p\u003e\n\u003cp\u003eAfter any cleaning procedure is performed it is important to rehydrate the glass of a pH electrode by placing in storage solution for 15 minutes. After the probe is rehydrated then a calibration must be performed. This is very important for process probes since many are used to monitor and control the dosing of chemicals. It is critical that the probe is clean and calibrated in order for a meter to maintain the ideal set point. The cleaning of pH and ORP process probes should be part of a routine maintenance program.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-01-08_at_3.20.38_PM.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eAir tight bottle with tamper-proof seal\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eEach bottle marked with lot number and expiration date.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eHanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70614L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line General Purpose Cleaning Solution (500 mL) - HI70614L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e general purpose cleaning solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70614L\"\u003ePool Line General Purpose Cleaning Solution (500 mL) - HI70614L\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871367790961,"sku":"HI70614L","price":1900.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70614l.jpg?v=1792646275"},{"product_id":"pool-line-cleaning-solution-for-oils-and-lotions-500-ml-hi70774l","title":"Pool Line Cleaning Solution for Oils and Lotions (500 mL) - HI70774L","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note,  because during calibration,  the instrument assumes that the electrode is clean and that the standardization curve created during the calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result as any changes to the surface occurs.\u003c\/p\u003e\n\u003cp\u003eThe HI70774L Pool Line Cleaning Solution is ideal for Service Technicians in the routine maintenance of process pH and ORP probes used in monitoring and control of swimming pools,  hot tubs,  and spas. The cleaning solution will ensure that the probes are cleaned of any oils that have accumulated on the probes. The proper maintenance and calibration of pH and ORP probes is critical when using with process meters for maintaining desired set points.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-01-08_at_3.20.38_PM.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eCleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. By simply immersing the electrode in the HI70774L cleaning solution for 15 to 20 minutes will dissolve any oily residues. The probe should then be placed in storage solution for 15 minutes to allow for hydration of a pH or ORP electrode. After hydration then the probe can be calibrated.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70774L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Cleaning Solution for Oils and Lotions (500 mL) - HI70774L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e cleaning solution for oils and lotions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70774L\"\u003ePool Line Cleaning Solution for Oils and Lotions (500 mL) - HI70774L\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871384764785,"sku":"HI70774L","price":3569.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70774l.jpg?v=1792646307"},{"product_id":"pool-line-low-range-phosphate-checker-hc-hi7134","title":"Pool Line Low Range Phosphate Checker HC - HI7134","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI7134 Pool Line Checker HC is designed for the measurement of low levels of phosphate in swimming pools, hot tubs, and spas. The HI7134 can measure phosphate from 0.00 to 2.50 ppm (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e). Phosphate can be introduced into a swimming pool by either the water that is being added or the breakdown of organic materials such as leaves and grass clippings. Phosphate is commonly added to municipal drinking water to minimize the corrosion of pipes in the distribution system. At high levels phosphate is a nutrient that encourages algae growth. From pool companies, it is recommend to keep phosphate less than 1000 ppb (1.0 ppm) to prevent algae from growing. The water can be treated with chemicals to remove phosphate and the HI7134 Pool Line Checker can be used to monitor and track changes to the phosphate level.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of this Checker HC fits in the palm of your and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eTo perform a measurement the instrument a water sample is placed into a cuvette and the meter is zeroed. Next, a reagent is added that will react with phosphate to produce a blue color. Last, place the vial into the Checker HC, press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Low Range Phosphate Checker HC - HI7134\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm ± 4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e Edition, Ascorbic Acid Method. The reaction between phosphate and the reagent causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 10 minutes of non-use and 2 minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7134 Checker HC is supplied with sample cuvettes with caps (2 pcs.), phosphate low range reagent starter kit (6 tests), 1.5VAAA battery (1 pc), and instructions that are packaged into a plastic case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7134\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Low Range Phosphate Checker HC - HI7134\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390237041,"sku":"HI7134","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7134.jpg?v=1792646330"},{"product_id":"pool-line-phosphate-low-range-checker-hc-calibration-check-set-hi7134-11","title":"Pool Line Phosphate Low Range Checker® HC Calibration Check Set - HI7134-11","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI7134-11 is a high-quality set of calibration standards that allows users to validate the performance HI7134 Pool Line Phosphate Low Range Checker® HC. The HI7134-11 includes one sealed cuvette for zeroing the meter and one cuvette that contains a standard with a value of 1.00 ±0.08 ppm phosphate sample @ 25℃. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eThe HI7134-11 is Supplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7134-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Phosphate Low Range Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI7134-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7134-11 is supplied with HI7134-11A – phosphate low range certified standard cuvette - A (1 pc.), HI7134-11B – phosphate low range certified standard cuvette – B (1 pc.), HI7134-0 phosphate reagent (1 pc.), certificate of analysis, and instruction for use.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7134-11\"\u003ePool Line Phosphate Low Range Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI7134-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390269809,"sku":"HI7134-11","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7134-11.jpg?v=1792646331"},{"product_id":"pool-line-low-range-phosphate-checker-hc-reagents-25-tests-hi7134-25","title":"Pool Line Low Range Phosphate Checker HC Reagents (25 Tests) - HI7134-25","description":"\u003cp\u003eHI7134-25 Pool Line Low Range Phosphate Checker HC Reagents are high-quality reagents that are pre-measured,  allowing users to achieve fast and accurate measurements with the HI7134 Low Range Phosphate Checker® HC. These reagents follow the Ascorbic Acid Method in which the reaction between phosphate and reagent causes a blue tint in the sample. By simply adding the packet of HI7134-25 reagent to the sample,  the reaction will take place and the HI7134 will determine the concentration from the color that is produced. The results will be displayed in ppm (mg\/L) of phosphate. HI7134-25 Pool Line Low Range Phosphate Checker HC Reagents are designed to be used when measuring swimming pool,  hot tub,  or spa water that has an expected range of 0.00 to 2.50 ppm phosphate.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7134-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Low Range Phosphate Checker HC Reagents (25 Tests) - HI7134-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e adaptation of the Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, Ascorbic Acid method. The reaction between phosphate and the reagent causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7134-25\"\u003ePool Line Low Range Phosphate Checker HC Reagents (25 Tests) - HI7134-25\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390302577,"sku":"HI7134-25","price":1020.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7134-25.jpg?v=1792646331"},{"product_id":"pool-line-high-range-iron-checker-hc-hi7214","title":"Pool Line High Range Iron Checker HC - HI7214","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eMany water sources can contain iron. The exact concentration will depend on geographic region and whether the water is from a lake, river, or groundwater. Groundwater will typically have the highest since minerals are picked up as rain percolates through the soil to the aquifers below. Iron in swimming pools, spas, and hot tubs present different problems. One problem is staining. Iron will be introduced in a reduced state and as it is exposed to air or other oxidizers, such has chlorine or bromine, the iron will be oxidized causing rust stains. The reaction of iron with oxidizers will create an increase demand for the oxidizers required to maintain a consistent disinfection level. A high demand in chorine could indicate an iron issue in which the water should either be pre-treated before adding to the body of water or treated by filtering it out.\u003c\/p\u003e\n\u003cp\u003eHI7214 Pool Line Checker Handheld Colorimeter is designed for the measurement of iron in swimming pools, hot tubs, and spas within a 0.00 to 5.00 ppm (mg\/L) range. The contoured style of these Checkers fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eTo perform a measurement the instrument a water sample is placed into a cuvette and the meter is zeroed. Next, a reagent is added that will react with iron to produce an orange color. Last, place the vial into the Checker, press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line High Range Iron Checker HC - HI7214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 ppm (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method. The reaction between iron and reagent causes an orange tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 10 minutes of non-use and 2 minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7214 Checker HC is supplied with sample cuvettes with caps (2pcs. each), iron high range starter reagent kit (6 tests), 1.5VAAA battery (1), and instructions packaged into a carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7214\" target=\"_blank\" rel=\"noopener\"\u003ePool Line High Range Iron Checker HC - HI7214\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391613297,"sku":"HI7214","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7214.jpg?v=1792646348"},{"product_id":"pool-line-iron-checker-hc-calibration-check-set-hi7214-11","title":"Pool Line Iron Checker HC Calibration Check Set - HI7214-11","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI7214-11 is a high-quality set of calibration standards that allows users to validate the performance HI7214 Pool Line Iron Checker® HC. The HI7214-11 includes one sealed cuvette for zero ppm Iron and one cuvette with a standard that is 1.00 ±0.06 ppm Iron @ 25℃. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eThe HI7214-11 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7214-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Iron Checker HC Calibration Check Set - HI7214-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7214-11 is supplied with HI7214-11A - iron certified standard cuvette - A (1 pc.), HI7214-11B - iron certified standard cuvette – B (1 pc.), certificate of analysis, and instruction for use.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7214-11\"\u003ePool Line Iron Checker HC Calibration Check Set - HI7214-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391646065,"sku":"HI7214-11","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7214-11.jpg?v=1792646349"},{"product_id":"pool-line-high-range-iron-checker-hc-reagents-25-tests-hi7214-25","title":"Pool Line High Range Iron Checker HC Reagents (25 Tests) - HI7214-25","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7214-25_certificate.jpg\" alt=\"HI721 iron checker HC CAL Check standards\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eHI7214-25 Pool Line Free Iron Checker HC Reagents are high-quality reagents that are pre-measured,  allowing users to achieve fast and accurate measurements with the HI7214 High Range Iron Checker HC. These reagents follow the Phenanthroline Method in which the reaction between iron and reagent causes an orange tint in the sample. By simply adding the packet of HI7214-25 reagent to the sample,  the reaction will take place and the HI7214 will determine the concentration from the color that is produced. The results will be displayed in ppm (mg\/L) of iron. HI7214-25 Pool Line Iron Checker HC Reagents are designed to be used when measuring swimming pool,  hot tub,  or spa water that has an expected range of 0.00 to 5.00 ppm iron.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7214-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line High Range Iron Checker HC Reagents (25 Tests) - HI7214-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e adaptation of the Standard Methods for the Examination of Water and Wastewater, 23rd Edition, 3500-Fe B, Phenanthroline Method. The reaction between iron and   reagent causes an orange tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7214-25\"\u003ePool Line High Range Iron Checker HC Reagents (25 Tests) - HI7214-25\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391678833,"sku":"HI7214-25","price":1020.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7214-25.jpg?v=1792646349"},{"product_id":"pool-and-spa-photometer-hi83326","title":"Pool and Spa Photometer - HI83326-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI83326 benchtop photometer measures 11 different key water quality parameters using 12 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eMade with the pool and spa industry in mind, a basic necessity of pool water treatment is to maintain the water in a safe and pleasant condition for the swimmers. In pool and spa water treatment, disinfection is essential to rid the pool of bacteria and control nuisance organisms like algae which may occur in the pool, spa, filtration equipment, or piping. There are a number of available disinfectant compounds including chlorine, bromine, and ozone. In order to achieve ideal water conditions, water requires testing on a daily and sometimes hourly basis to ensure there is enough residual disinfectant and to maintain pH levels. Equally important is calcium hardness and alkalinity; these levels should be monitored weekly to ensure the pool or spa water is well balanced to avoid corrosion and scale formation.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\n\u003cp\u003eThe HI83326 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eBacklit 128 x 64 Pixel Graphic LCD Display\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit graphic display allows for easy viewing in low light conditions\u003c\/li\u003e\n\u003cli\u003eThe 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement is taken after the countdown timer expires.\u003c\/li\u003e\n\u003cli\u003eCountdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAbsorbance mode\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHanna's exclusive CAL Check cuvettes for validation of light source and detector\u003c\/li\u003e\n\u003cli\u003eAllows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUnits of Measure\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAppropriate unit of measure along with chemical form is displayed along with reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eResult Conversion\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAutomatically convert readings to other chemical forms with the touch of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCuvette Cover\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAids in preventing stray light from affecting measurements\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eDigital pH Electrode Input\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH and temperature with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eSpace saving having a pH meter and photometer built into one meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button\u003c\/li\u003e\n\u003cli\u003eSample ID and User ID information can be added to a logged reading using alphanumeric keypad\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port\u003c\/li\u003e\n\u003cli\u003eData is exported as a .CSV file for use with common spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBattery Status Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eIndicates the amount of battery life left\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eError Messages\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePhotometric error messages include no cap, high zero, and standard too low\u003c\/li\u003e\n\u003cli\u003epH calibration messages include clean electrode, check buffer and check probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/method-selection.png\" alt=\"method selection\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMethod Selection\u003c\/h4\u003e\n\u003cp\u003eUsers can easily select any one of the 20 measurement methods via the dedicated METHOD button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/data-logging.png\" alt=\"data logging\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eData Logging\u003c\/h4\u003e\n\u003cp\u003eUp to 1000 measurement readings can be logged with user and sample ID and recalled for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-measurement-mode.png\" alt=\"ph measurement mode\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003epH Measurement Mode\u003c\/h4\u003e\n\u003cp\u003eSelecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdvanced Optical System\u003c\/h4\u003e\n\u003cp\u003eHI83326 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/OpticalSystem.jpg\" alt=\"photometer multiparameter optical\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHigh Efficiency LED Light Source\u003c\/h4\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch4\u003eHigh Quality Narrow Band Interference Filters\u003c\/h4\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (±1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch4\u003eReference Detector for a Stable Light Source\u003c\/h4\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the HI83326 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch4\u003eLarge Cuvette Size\u003c\/h4\u003e\n\u003cp\u003eThe sample cell of the HI83326 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch4\u003eFocusing Lens for Greater Light Yield\u003c\/h4\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI83326-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool and Spa Photometer - HI83326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH\npH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH\npH electrode: 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH\npH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 ℃; 23.0 to 212.0 °F); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 4.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.003Abs @ 1.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 8.00 mg\/L (as Br\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003eHigh range: 0.00 to 5.00 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003eHigh Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±15% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003eHigh Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003eHigh Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eHigh Range: Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0.00 to 2.50 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±0.04 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: Adaptation of the Ascorbic Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 3 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003edigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e3 LEDs with 525 nm, 575 nm, and 610 nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e128 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003ecalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003elog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery \/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0 ℃ (32 to 122.0 °F); 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI83226 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI83326-01\" target=\"_blank\" rel=\"noopener\"\u003ePool and Spa Photometer - HI83326\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871411798385,"sku":"HI83326-02","price":105387.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83326-upper-angle-cover-closed_1.jpg?v=1792646512"},{"product_id":"pool-line-alkalinity-checker-hc-hi7754","title":"Pool Line Alkalinity Checker HC - HI7754","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI7754 Pool Line Checker® Handheld Colorimeter is designed for the measurement of alkalinity in swimming pools, hot tubs, and spas. Alkalinity is a very important parameter in monitoring swimming pool water chemistry. Alkalinity is the buffering capacity of a solution to resist a pH change from the addition of an acid or base. This can be a challenge when using common forms of chlorine, in that, as a base when the chlorine is added the pH will increase. As the pH of the water increased above pH 7.4 the chlorine becomes predominately in the hypochlorite form instead of the hypochlorous acid as the pH decreases from pH 7.4. Hypochlorous acid is 100 times more effective as a sanitizer than the hypochlorite form. When water is low in alkalinity the pH will increase as the chlorine is added. When there is adequate alkalinity then as the chlorine is added the base is absorbed and the pH remains the same. Monitoring alkalinity is important in maintaining a stable pH of a swimming pool hot tub, or spa.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of these Checkers’ fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eTo perform a measurement the instrument a water sample is placed into a cuvette and the meter is zeroed. Next, a reagent is added that will react with alkalinity to produce a distinctive range of colors from yellow to greenish-blue. Last, place the vial into the Checker, press the button and read the results. It’s that easy. It is important to note that if chlorine is in the water sample to be tested then it is necessary to add HI937554-53 chlorine remover first before proceeding with the test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Alkalinity Checker HC - HI7754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 ppm (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 ppm ± 5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ecolorimetric Method. The reaction causes a distinctive range of colors from yellow to greenish blue to develop. This checker has been developed to work with fresh water samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 10 minutes of non-use and 2 minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7754 Checker HC is supplied with sample cuvettes with caps (2 pcs.), Alkalinity reagent starter (25 tests), 1.5VAAA battery (1 pc.), and instructions all packaged into a custom carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7754\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Alkalinity Checker HC - HI7754\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871413010801,"sku":"HI7754","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7754.jpg?v=1792646524"},{"product_id":"pool-line-alkalinity-checker-hc-reagents-25-tests-hi7754-26","title":"Pool Line Alkalinity Checker HC Reagents (25 Tests) - HI7754-26","description":"\u003cp\u003eThe HI7754-26 are high-quality reagents that are pre-measured,  allowing for users to achieve fast and accurate measurements with their Freshwater Alkalinity Checker® HC. These reagents follow a colorimetric method in which the reaction causes a distinctive range of colors from yellow to green to blue to develop. By simply adding one drop of the Chlorine Remover to remove the chlorine interference,  and subsequently adding 1 mL of the Alkalinity Reagent to the sample,  the reaction will take place and the HI7754 Pool Line Checker HC for alkalinity will determine the concentration from the color that is produced. The results will be displayed in ppm of CaCO\u003csub\u003e3\u003c\/sub\u003e. These reagents are designed to be used with samples that have an expected range of 0 to 500 ppm CaCO\u003csub\u003e3\u003c\/sub\u003e.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7754-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Alkalinity Checker HC Reagents (25 Tests) - HI7754-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Colorimetric method. The reaction causes a distinctive range of colors from yellow to blue to develop. These reagents have been developed to work with fresh water samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7754-26\"\u003ePool Line Alkalinity Checker HC Reagents (25 Tests) - HI7754-26\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871413076337,"sku":"HI7754-26","price":2920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7754-26.jpg?v=1792646525"},{"product_id":"pool-line-alkalinity-checker-hc-calibration-check-set-hi7754-11","title":"Pool Line Alkalinity Checker HC Calibration Check Set - HI7754-11","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI7754-11 is a high-quality set of calibration standards that allows users to validate the performance HI7754 Pool Line Alkalinity Checker® HC. The HI7754-11 includes one sealed cuvette for zero ppm CaCO\u003csub\u003e3\u003c\/sub\u003e and one cuvette that is tinted to an equivalent 100 ±10 ppm CaCO\u003csub\u003e3 \u003c\/sub\u003esample @ 25℃. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eThe HI7754-11 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7754-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Alkalinity Checker HC Calibration Check Set - HI7754-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7754-11 is supplied with HI7754-11A - alkalinity certified standard cuvette - A (1 pc.), HI7754-11B - alkalinity certified standard cuvette – B (1 pc.), certificate of analysis, and instruction for use.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7754-11\"\u003ePool Line Alkalinity Checker HC Calibration Check Set - HI7754-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871413141873,"sku":"HI7754-11","price":2920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7754-11.jpg?v=1792646525"},{"product_id":"pool-line-ph-checker-hc-calibration-check-set-hi779-11","title":"Pool Line pH Checker® HC Calibration Check Set - HI779-11","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI779-11.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI779-11 è composto da due cuvette standard per la verifica della calibrazione,  che permettono all'utente di convalidare il Checker® HC HI779 per pH della serie Pool Line. HI779-11 include due cuvette sigillate; una contenente un campione per l’azzeramento dello strumento ed una cuvetta contenente una soluzione colorata corrispondente al valore di 8.0 pH ±0.1 pH a 25℃. Gli standard per calibrazione vengono prodotti nei nostri stabilimenti ISO 9001,  utilizzando prodotti chimici e materiali certificati,  in un ambiente a temperatura controllata\u003c\/p\u003e\n\u003cp\u003eHI779-11 è fornito con il Certificato di analisi\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCodice prodotto\u003c\/li\u003e\n\u003cli\u003eNumero di lotto\u003c\/li\u003e\n\u003cli\u003eData di scadenza\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI779-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line pH Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI779-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI779-11 is supplied with HI779-11A - pH certified standard cuvette - A (1), HI779-11B - pH certified standard cuvette – B (1), certificate of analysis, and instruction for use.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI779-11\"\u003ePool Line pH Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI779-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871413174641,"sku":"HI779-11","price":1900.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi779-11-720x720-103035d0-0c6c-4f39-871a-0c41cd239048.png?v=1792646525"},{"product_id":"cal-check-cuvette-kit-for-hi83326-pool-and-spa-photometer-hi83326-11","title":"CAL Check Cuvette Kit for HI83326 Pool and Spa Photometer - HI83326-11","description":"\u003cp\u003eHI83326-11 is a set of high-quality calibration standards that allow users to validate absorbance measurements for the HI83326 Pool and Spa Photometer. The HI83326-11 includes six sealed cuvettes,  including one to zero the meter. The calibration set is produced in Hanna Instrument’s state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch5\u003eSupplied with Certificate of Analysis,  which contains:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003cli\u003eStandard value at 25℃\u003c\/li\u003e\n\u003cli\u003eReference meter NIST traceable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eValidation of the HI83326 Pool and Spa Photometer is quick and easy with CAL Check Standards. The CAL Check screen guides the user through the measurement of each standard and applies the factory calibration corrections to each measurement. The HI83326 stores the results of the most recent CAL CheckT measurements which may be viewed on the CAL Check menu. Compare these results with the values printed on the Certificate provided with each HANNA® CAL Check Standards kit.\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eTo perform a validation:\u003c\/li\u003e\n\u003cli\u003ePress Setup button.\u003c\/li\u003e\n\u003cli\u003eHighlight CAL Check,  then press Select.\u003c\/li\u003e\n\u003cli\u003eFollow the prompts on the screen. The meter will prompt to measure each cuvette provided in the HANNA® CAL Check Standards kit.\u003c\/li\u003e\n\u003cli\u003eYou are now ready to perform a measurement.\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI83326-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI83326-11 CAL Check Cuvette Kit for HI83326 Pool and Spa Photometer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI83326-11\"\u003eHI83326-11 CAL Check Cuvette Kit for HI83326 Pool and Spa Photometer\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871415861617,"sku":"HI83326-11","price":17958.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83326-11-720x720-213592ba-0f52-4dcf-ac71-e62ff49056a2_1.png?v=1792646554"},{"product_id":"pool-line-chlorine-removal-kit-hi937554-53","title":"Pool Line Chlorine Removal Kit - HI937554-53","description":"\u003cp\u003eThe HI937554-53 is a reducing reagent used to remove the interference from chlorine when measuring alkalinity with the HI7754 Pool Line Alkalinity Checker HC. One drop of HI937554-53 reagent is added to sample vial prior to adding the reagents used to determine alkalinity.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93755-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI93755-53 Chlorine Remover Reagent for HI775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93755-53\"\u003eHI93755-53 Chlorine Remover Reagent for HI775\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871433851249,"sku":"HI937554-53","price":1303.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi937554-53.jpg?v=1792646703"},{"product_id":"pool-line-ph-alkalinity-free-amp-total-chlorine-and-cyanuric-acid-portable-photometer-hi971044","title":"Pool Line pH,  Alkalinity,  Free \u0026amp; Total Chlorine,  and Cyanuric Acid Portable Photometer - HI971044","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eFree and Total Chlorine, pH, Alkalinity, and Cyanuric Acid are some of the most important parameters when maintaining a safe and clean pool.\u003c\/p\u003e\n\u003cp\u003eChlorine is a common chemical used by many due to is disinfection properties. Free chlorine can exist in two forms and which form is present is based on the pH. At pH less than 7.6 hypochlorous acid (HOCl) is the predominate form found while at pH greater than 7.6 the hypochlorite (OCl-) form becomes predominate. This is very important when it comes to preventing biological growth in water or keeping a swimming pool safe since hypochlorous acid is 100 times more effective as a sanitizer. Total chlorine represents both the free chlorine and combined chlorine present. Combined chlorine is the chlorine bound to nitrogen substances such as ammonia. In swimming pools, combined chlorine that we can smell, is irritating to the eyes. A free chlorine measurement is subtracted from a total chlorine measurement to determine how much combined chlorine is present.\u003c\/p\u003e\n\u003cp\u003eAlkalinity is also a very important parameter in monitoring swimming pool water chemistry. Alkalinity is the buffering capacity of a solution to resist change from an acid or base. Chlorine can also be a base that will increase the pH of the water as it is added to it. Having a sufficient level of alkalinity helps to buffer against the pH so that it takes more over time in order to cause a pH change.\u003c\/p\u003e\n\u003cp\u003eCyanuric acid is often added to a swimming pool to prevent the loss of chlorine to sunlight. Cyanuric acid is commonly found in dry chlorine such as trichloroisocyanurate (trichlor). This form can be purchased as a solid “puck” and placed in flotation devices to erode slowly into the water. Maintaining the proper level of cyanuric acid will increase the life of chlorine in the pool. Cyanuric acid will build up overtime as more chemical is added. Unfortunately, having too much will decease the Redox (ORP) potential that is effective at killing the bacteria in the pool. For this reason cyanuric acid should be measured for pools that are using it as a stabilizer.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eImportant Note: \u003c\/strong\u003eChlorine by DPD chemical measurement is preferred over ORP measurements due to the masking of the oxidation potential from chlorine and other oxidizers when using cyanuric acid (isocyanurate containing sanitizers) as a stabilizer. It will be possible to obtain a 625 -650 mV ORP reading when using cyanuric acid.\u003c\/p\u003e\n\u003cp\u003eHI971044 allows any user to measure these key swimming pool water quality parameters with laboratory grade accuracy. The reagents are pre-made and the meter offers a tutorial mode to guide the user step by step in performing the measurements.\u003c\/p\u003e\n\u003cp\u003eThe HI971044 has an innovative optical system that offers superior performance in accuracy, repeatability, and the short amount of time it takes to perform a measurement. This compact, waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically, step by step, in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different units of measure, reviewing GLP data, recalling the last 50 measurements, and customizing the meter to user preferences.\u003c\/p\u003e\n\u003cp\u003eHI971044 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/PHOTOMETER-OPTICAL-SYSTEM.jpg\" alt=\"photometer optical system\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cul\u003e\u003cli\u003e\u003cul\u003e\u003cli\u003eLED that generates very little heat\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cul\u003e\u003cli\u003e8 nm narrowband interference filter that is accurate to ±1 nm and offers 25% increase in light efficiency.\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cul\u003e\u003cli\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/li\u003e\u003c\/ul\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Cal_Check.jpg\" alt=\"CAL Check HI97700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eAdvanced features including CAL-Check to verify performance, GLP for last calibration date, setup options, and the ability to see all accessories used with the meter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/tutorial.jpg\" alt=\"tutorial mode HI97104\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eTutorial Mode\u003c\/h4\u003e\n\u003cp\u003eWhen enabled, the tutorial mode will guide the user step by step through the measurement process .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Method_Selection.jpg\" alt=\"method option\" width=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMethod Options\u003c\/h4\u003e\n\u003cp\u003eChoice of powder or economical liquid reagents for chlorin measurments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHI97104 FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch5\u003eStable Light Source:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe internal reference system of the HI9771044 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh Efficiency Light Source:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce little heat, which could otherwise affect electronic stability.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh Quality Filters:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter, stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGreater Light Yield:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eA focusing lens collects all of the light that exits the cuvette, eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCAL Check Functionality:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between sample measurements and users.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge Cuvette Size:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe sample cell of the HI971044 fits a round, glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eIntuitive Dot Matrix Display:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe HI971044 is designed with a backlit, graphic LCD. With virtual keys, a battery status indicator, and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation, and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-off Protection:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI971044-kit.jpg\" alt=\"HI971044 is available as a kit\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eThe HI971044 is available as a kit (HI97104C) which includes:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePortable Photometer\u003c\/li\u003e\n\u003cli\u003eSample cuvettes (2)\u003c\/li\u003e\n\u003cli\u003eCaps\u003c\/li\u003e\n\u003cli\u003eCAL Check™ standards with certificate\u003c\/li\u003e\n\u003cli\u003eCuvette cleaning cloth\u003c\/li\u003e\n\u003cli\u003eScissors\u003c\/li\u003e\n\u003cli\u003eRugged carrying case\u003cul\u003e\u003cli\u003eCarrying case has thermoformed insert for meter and accessories\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI971044-certi.jpg\" alt=\"certificate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003e*Reagents ordered separately\u003c\/h5\u003e\n\u003ch5\u003eCAL Check™ standards with certificate\u003c\/h5\u003e\n\u003cp\u003eThe CAL Check™standards are used for calibration and performance verification of photometers with the CAL Check™ function. Individual sets of CAL Check™ standards are available for each parameter on the HI971044:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH: HI977794-11\u003c\/li\u003e\n\u003cli\u003eChlorine: HI97701-11\u003c\/li\u003e\n\u003cli\u003eAlkalinity: HI97775-11\u003c\/li\u003e\n\u003cli\u003eCyanuric Acid: HI97722-11\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eSupplied with Certificate of Analysis\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003cli\u003eStandard value @ 25°C\u003c\/li\u003e\n\u003cli\u003eReference meter NIST traceable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eProvided storage containers\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLight tight\u003c\/li\u003e\n\u003cli\u003eProtects from accidental breakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI971044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line pH, Alkalinity, Free \u0026amp; Total Chlorine, and Cyanuric Acid Portable Photometer - HI971044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e6.5 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003ephenol red method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 mg\/L (as CaCO3)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ecolorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of US EPA method 330.5, DPD Colorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±15% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003elight emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell with narrow band interference filter @ 525 nm and 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points Stored\u003c\/td\u003e\n\u003ctd\u003e50 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5 V AA Alkaline (3 pcs.) \/ \u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 15 minutes of inactivity(30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); 0 to 100% RH, IP67, floating case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI971044C (Kit version) is supplied with sample cuvettes and caps (2 pcs. Each), plastic stopper (2 pcs.), A Zero CAL Check Cuvette A, HI97701B CAL Check cuvette B for free and total chlorine, HI977794B CAL Check cuvette B for pH, HI97722B CAL Check cuvette B for cyanuric acid, HI97775B CAL Check cuvette B for alkalinity, scissors, cuvette cleaning cloth, 1.5V AA batteries (3 pcs.), CAL Check standard certificates, instrument quality certificate, and instruction manual packaged in a rugged carrying case.\u003cbr\u003e\nHI971044 (Meter only) is supplied with cuvettes and caps (2 pcs. each), plastic stopper (2 pcs.), 1.5V AA batteries (3), instrument quality certificate, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI971044\" target=\"_blank\" rel=\"noopener\"\u003ePool Line pH, Alkalinity, Free \u0026amp; Total Chlorine, and Cyanuric Acid Portable Photometer - HI971044\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871439159665,"sku":"HI971044","price":45928.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi971044.jpg?v=1792646751"},{"product_id":"pool-line-ph-cal-checktm-kit-for-hi971044-portable-photometer-hi977794-11","title":"Pool Line pH CAL Check™ Kit for HI971044 Portable Photometer - HI977794-11","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI977794-11 is a high-quality set of calibration standards that allows users to validate the performance the pH measurement of the HI971044 Pool Line pH, free and total chlorine, alkalinity and cyanuric acid portable photometer. The HI977794-11 includes one sealed cuvette for zero (unreacted sample known as a blank) and one cuvette that is tinted to a pH 8.0 value. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eThe HI977794-11 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI977794-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line pH CAL CheckTM Cuvette Kit for HI971044 Portable Photometer - HI977794-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI977794-11 is supplied with HI977794-11A - pH certified standard cuvette - A (1 pc.), HI977794-11B - pH certified standard cuvette – B (1 pc.), certificate of analysis, and instruction for use.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI977794-11\" target=\"_blank\" rel=\"noopener\"\u003ePool Line pH CAL CheckTM Cuvette Kit for HI971044 Portable Photometer - HI977794-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871450759537,"sku":"HI977794-11","price":20224.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi977794-11.jpg?v=1792646873"},{"product_id":"pool-line-ph-amp-temperature-pocket-tester-with-0-1-ph-resolution-hi981074","title":"Pool Line pH \u0026amp; Temperature Pocket Tester with 0.1 pH Resolution - HI981074","description":"\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cp\u003eSlim, ergonomic design that fits comfortably in the hand or pocket\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator and calibration tags\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eCalibration to one or two points with standard buffers (pH 4.01, 7.01, and 10.01)\u003c\/p\u003e\n\u003cp\u003eStability indicator confirms the reading has stabilized\u003c\/p\u003e\n\u003cp\u003eExtractable cloth junction to clear clogging\u003c\/p\u003e\n\u003cp\u003eAutomatic shut-off with three user controlled settings to conserve battery life\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line pH \u0026amp; Temperature Pocket Tester with 0.1 pH Resolution - HI981074\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-points (pH 4.01 \/ 7.01 \/ 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, 0 to 50 oC (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e8 minutes, 60 minutes, or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 3V Li-Ion \/ approximately 800 hours of use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e65 g (2.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981074\" target=\"_blank\" rel=\"noopener\"\u003ePool Line pH \u0026amp; Temperature Pocket Tester with 0.1 pH Resolution - HI981074\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451251057,"sku":"HI981074","price":5511.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981074.jpg?v=1792646879"},{"product_id":"pool-line-waterproof-orp-amp-temperature-tester-hi981204","title":"Pool Line Waterproof ORP \u0026amp; Temperature Tester - HI981204","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003e2 sensors in a single meter\u003c\/p\u003e\n\u003cp\u003eWaterproof casing designed to float if dropped in water\u003c\/p\u003e\n\u003cp\u003eORP range of ±1000 mV\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eHOLD button for easier measurement recording\u003c\/p\u003e\n\u003cp\u003eBattery Error Prevention System (BEPS)\u003c\/p\u003e\n\u003cp\u003eReplaceable, platinum ORP Electrode\u003c\/p\u003e\n\u003cp\u003eAutomatic shut-off with three user controlled settings\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Waterproof ORP \u0026amp; Temperature Tester - HI981204\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0 °C (23.0 to 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4)\/ Approximately 300 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50 °C (23 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e83 g (2.9 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981204 is supplied with HI700224 470 mV ORP test solution, 20 ml sachet (6 pcs.), 20 mL sachet (1 pc.), HI73120 ORP electrode, HI73128 Electrode removal tool, storage\/protection cap, 1.5V batteries (4 pcs.), instrument quality certificate, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981204\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Waterproof ORP \u0026amp; Temperature Tester - HI981204\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451644273,"sku":"HI981204","price":23291.55,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981204.jpg?v=1792646885"},{"product_id":"pool-line-combo-ph-orp-tester-hi981214","title":"Pool Line Combo pH\/ ORP Tester - HI981214","description":"\u003cp\u003eHI981214 Pool Line Combo tester is a highly accurate, waterproof pH meter that can also measure ORP and temperature. This floating, waterproof combination tester has an easy to read, LCD and an automatic shut-off. All pH readings are automatically temperature compensated (ATC) for variations in temperature.\u003c\/p\u003e\n\u003cp\u003eHI981214 is ideal for checking the pH and disinfection levels of swimming pools, hot tubs, and spas. The accurate reading of pH is critical to ensure that the chlorine is in predominately the hypochlorous acid form instead of the hypochlorite form, which is less effective at killing bacteria. The ideal pH for a pool is between 7.2 and 7.4.\u003c\/p\u003e\n\u003cp\u003eThe ORP portion of the meter is used to monitor the disinfection level of the pool to always be sure that there is enough chlorine present to keep bathers safe from bacteria. The ideal ORP reading is +650 mV. At this voltage any bacteria will be inactivated in a short time. It is important to note that if a stabilizer such as cyanuric acid is used that the stabilizer as a reducing agent will mask the oxidation potential of chlorine. ORP should not be used when chlorine is introduced as solid puck since it is likely that it will have stabilizers as well.\u003c\/p\u003e\n\u003ch5\u003eReplaceable ORP Electrode Cartridge\u003c\/h5\u003e\n\u003cp\u003eThe HI981214 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!\u003c\/p\u003e\n\u003ch5\u003ePlatinum ORP Electrode\u003c\/h5\u003e\n\u003cp\u003eThe ORP probe uses a platinum tip sensor, which is ideal for oxidation reactions such as adding chlorine for disinfection.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance:\u003c\/h4\u003e\n\u003cp\u003e3 sensors in a single meter\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH electrode with extractable junction\u003c\/li\u003e\n\u003cli\u003eORP electrode\u003c\/li\u003e\n\u003cli\u003eTemperature probe for pH temperature compensated measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eWaterproof\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eDesigned to float if accidently dropped in sample\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eWide Range\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003epH range is from -2.00 to 16.00 pH\u003c\/li\u003e\n\u003cli\u003eORP range of ±1000 mV\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eAutomatic Temperature Compensation\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAll pH readings are compensated for variations in temperature\u003c\/li\u003e\n\u003cli\u003eTemperature displayed in oC or oF along with pH or ORP reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eStability indicator\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eHOLD button\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eFreezes reading on the display to allow recording of measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBEPS (Battery Error Prevention System\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eBattery % level at startup\u003c\/p\u003e\n\u003cp\u003eLow Battery Indicator\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAuto-off\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eAuto-off feature automatically shuts off the meter after 8 minutes of non-use to maximize battery life\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Combo pH\/ ORP Tester - HI981214\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0 °C (23.0 to 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4)\/ Approximately 250 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50 °C (23 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e83 g (2.9 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981214 is supplied with HI700044 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI700074 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI7003004 storage solution for pH \u0026amp; ORP electrodes, 20 mL sachet (1 pc.), HI700224 470 mV ORP test solution, 20 ml sachet (2 pcs.), HI7006014pH \u0026amp; ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, storage\/protection cap, 1.5V batteries (4 pcs.), instrument quality certificate, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981214\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Combo pH\/ ORP Tester - HI981214\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451677041,"sku":"HI981214","price":31626.45,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981214.jpg?v=1792646885"},{"product_id":"pool-line-ph-amp-temperature-tester-with-0-1-ph-resolution-hi981274","title":"Pool Line pH \u0026amp; Temperature Tester with 0.1 pH Resolution  - HI981274","description":"\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cp\u003eSlim, ergonomic design that fits comfortably in the hand or pocket\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eHOLD button for easier measurement recording\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation, displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eHI73127 replacement pH electrode has an extractable cloth junction\u003c\/p\u003e\n\u003cp\u003eAutomatic shut-off with three user settings\u003c\/p\u003e\n\u003cp\u003eBattery Error Prevention System (BEPS)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981274\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line pH \u0026amp; Temperature Tester with 0.1 pH Resolution - HI981274\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0 °C (23.0 to 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4)\/ Approximately 250 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50 °C (23 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e83 g (2.9 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981274 is supplied with HI700044 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI700074 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI7003004 storage solution for pH \u0026amp; ORP electrodes, 20 mL sachet (1 pc.), HI700224 470 mV ORP test solution, 20 ml sachet (2 pcs.), HI7006014pH \u0026amp; ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, storage\/protection cap, 1.5V batteries (4 pcs.), instrument quality certificate, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981274\" target=\"_blank\" rel=\"noopener\"\u003ePool Line pH \u0026amp; Temperature Tester with 0.1 pH Resolution - HI981274\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451775345,"sku":"HI981274","price":16248.6,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981274.jpg?v=1792646887"},{"product_id":"pool-line-combo-ph-ec-tds-tester-high-range-hi981304","title":"Pool Line Combo pH\/EC\/TDS Tester (High Range) - HI981304","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eAmperometric EC\/TDS sensor, pH electrode, and temperature probe in one meter\u003c\/p\u003e\n\u003cp\u003eHigh accuracy EC\/TDS graphite probe reduces polarization effects and does not oxidize\u003c\/p\u003e\n\u003cp\u003eSelectable EC to TDS conversion factor of 0.45 or 1.0\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation coefficient β (BETA), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eHOLD button for easier measurement recording\u003c\/p\u003e\n\u003cp\u003eBattery Error Prevention System (BEPS) with low battery indicator\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Combo pH\/EC\/TDS Tester (High Range) - HI981304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point calibration at 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point calibration at 6.44 ppt using 0.5 conversion factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic EC\/TDS: ß=0.0 to 2.4% \/ ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0 °C (32.0 to 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4)\/ Approximately 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e93 g (3.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981304 is supplied with HI700044 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI700074 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI7003004 Storage solution for pH \u0026amp; ORP electrodes, 20 mL sachet (1 pc.), HI700304 12880 µS\/cm conductivity standard, 20 mL sachet (1 pc.), HI700384 6.44 ppt TDS standard, 20 mL sachet (1 pc.), HI7006014pH \u0026amp; ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, Storage \/ Protection cap, 1.5V batteries (4 pcs.), Instrument quality certificate, and Instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981304\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Combo pH\/EC\/TDS Tester (High Range) - HI981304\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451906417,"sku":"HI981304","price":26357.4,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981304.jpg?v=1792646889"},{"product_id":"pool-line-professional-waterproof-portable-ph-orp-meter-hi981914","title":"Pool Line Professional Waterproof Portable pH\/ ORP Meter - HI981914","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHI981914 Pool Line Professional Waterproof Portable pH\/ORP meter is a highly accurate that is equivalent to meters used in laboratories. HI 981914 offers many advanced features from a large dot matrix LCD that provides for an intuitive user interface in the operation of the meter, log on demand for storing readings, USB port for transferring data, GLP data for tracking calibration data, and Hanna’s exclusive CAL Check for pH calibration diagnostics. During the calibration process the meter analyzes the mV signal being generated and provides warnings to whether the probe needs to be cleaned or of the buffer is contaminated. After calibration the meter displays the overall health of the pH electrode as a percentage and is based on both the offset (mV value in pH 7 buffer) and slope (mV difference from pH 7 to pH 4\/10) characteristics.\u003c\/p\u003e\n\u003cp\u003eThe HI981914 uses pH and ORP probes with a BNC connector. The BNC connector can be used with process probes for evaluation of their performance. For pH it is possible to set the meter to a “default” calibration that resets the meter to the ideal mV response for a pH probe. When this is done then it is possible to connect a pH probe and perform a calibration. CAL-Check will provide the diagnostic messages to indicate potential problems. For example if the meter display condition at 10% or flashing then it would be recommended to clean the probe. If after cleaning the probe and the condition remains low after a subsequent calibration then this would be an indicator that the probe is reaching it end of life. The probe characteristics can be reviewed using the GLP feature. An acceptable offset value is ±30 mV and the slope should be better than 90%. Values greater than ±60 mV or a slope less than 85% are indicators that the probe needs to be replaced in the near future to avoid a service calls due to probe failure or loss of control parameters.\u003c\/p\u003e\n\u003cp\u003eFor ORP probes the mV function and a 470 mV test solution is used to check the performance of an ORP electrode. A probe not reading correctly should be cleaned and the platinum sensor surface polished. If an acceptable value is not obtained then the ORP probe should be replaced.\u003c\/p\u003e\n\u003cp\u003eThe HI981914 can be used for process calibration as well in which the measurement is made with a calibrated pH probe or a measurement by an ORP probe and the value entered into a process controller to match the measured values.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSetup Screen\u003c\/h4\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981914-diagnostic.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCAL Check Probe Diagnostics\u003c\/h4\u003e\n\u003cp\u003eChoose from seven standard pH buffers and five custom values to obtain up to five-point calibration and achieve high precision readings with a 0.001 pH resolution and a pH accuracy of ±0.002.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP\u003c\/h4\u003e\n\u003cp\u003eComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003epH CAL Check™\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/li\u003e\n\u003cli\u003eDisplays overall probe condition based on offset and slope after calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFive point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eFive point ISE calibration with seven preprogrammed standard in choice of concentration\u003c\/h5\u003e\n\u003ch5\u003eISE direct concentration readout in a choice of concentration units\u003c\/h5\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003efreezes reading on display upon stabilization\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data including date, time, calibrated values, slope and offset (pH)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200-hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/h5\u003e\n\u003ch5\u003eBattery Error Prevention System (BEPS)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eTurns meter off when battery power is too low for an accurate measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Food \u0026amp; Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/1pmzf9o20h?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/2872b8cf233378bfb91dce12e7b14732390aacd8.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981914\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Professional Waterproof Portable pH\/ ORP Meter - HI981914\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0; -2.00 to 20.00; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1; 0.01; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e10¹² Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Relative Offset\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003eFrom 1.00 E-7 to 9.99 E10 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e3 digits 0.01, 0.1, 1, 10 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading (monovalent ions)\n±1% of reading (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C (-4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4 °C (±0.8 °F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI72911B titanium body pH \u0026amp; temperature probe (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e300 records, log on demand (100 records per pH, mV, or ISE range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e5, 10, 30, 60 minutes or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%, IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981914 is supplied with HI72911B pH electrode with built-in temperature sensor, HI7662 temperature probe, HI7004M pH 4.01 buffer (230 mL), HI7007M pH 7.01 buffer (230 mL), HI7006014 general purpose cleaning solution sachets (20 mL x 3 pcs.), 100 mL plastic beakers (2 pcs.), 1.5V AAA batteries (4 pcs.), HI920015 micro USB cable, instrument quality certificate, and instruction manual packaged in a rugged thermoformed carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981914\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Professional Waterproof Portable pH\/ ORP Meter - HI981914\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871453020529,"sku":"HI981914","price":94938.75,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981914.jpg?v=1792646905"},{"product_id":"pool-line-multiparameter-waterproof-portable-ph-orp-ec-temperature-meter-hi981954","title":"Pool Line Multiparameter Waterproof Portable pH\/ ORP\/EC\/Temperature Meter - HI981954","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHI981954 Pool Line Multiparameter Waterproof Portable Temperature meter is a single tool that allows swimming pool, hot tub, and spa service technicians to measure key water quality parameters for both traditional and electrolytic saltwater pools. The auto-ranging conductivity\/TDS readings can be used for low range readings to track the increase in chemicals as water evaporates from a pool and for the higher range measurement of salt required for the proper electrolysis of sodium chloride to produce chlorine.\u003c\/p\u003e\n\u003cp\u003eThe HI981954 can be used for both routine measurements and for process calibration in which the measurement information is then used to update the calibration of process pH, ORP and conductivity meters.\u003c\/p\u003e\n\u003cp\u003eHI981954 offers many advanced features from a large dot matrix LCD that provides for an intuitive user interface in the operation of the meter, log on demand for storing readings, USB port for transferring data, and GLP data for tracking calibration data. The HI98195 has 5 sensors (pH, ORP, EC, temperature, barometric pressure) and 6 interpretative measurements (pH in mV, absolute conductivity, TDS, resistivity, salinity, seawater sigma). The HI981954 can display up to 11 parameters simultaneously on the large dot matrix LCD. The readings can be scaled in size based on the number of parameters (1 to 11) that are displayed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981954-setupscreen.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSetup Screen\u003c\/h4\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981954-calibration.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eStandard or Quick Calibration\u003c\/h4\u003e\n\u003cp\u003eQuick Calibration provides a speedy, single point calibration for pH and conductivity. Standard pH calibration options are available for calibrating up to three points from a selection of five standard buffers and one custom buffer. Conductivity calibration is a single point from six standard selections or one custom standard.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI981954-glp.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP\u003c\/h4\u003e\n\u003cp\u003eComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including date, time, and calibration values are stored with logged data for retrieval at a later time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003epH CAL Check™\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFive point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eQuick Calibration of pH and EC sensors with a single solution\u003c\/h5\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003efreezes reading on display upon stabilization\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data including date, time, calibrated values, slope and offset (pH)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200-hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/h5\u003e\n\u003ch5\u003eBattery Error Prevention System (BEPS)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eTurns meter off when battery power is too low for an accurate measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981954\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Multiparameter Waterproof Portable pH\/ ORP\/EC\/Temperature Meter - HI981954\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 9999 µS\/cm; 0.000 to 200.0 mS\/cm (absolute EC up to 400.0 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003eauto-ranging: 1 µS\/cm from 0 to 9999 µS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm; auto-ranging (fixed mS\/cm): 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 from 100.0 to 400.0 mS\/cm ; manual: 1 µS\/cm; 0.001 mS\/cm; 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 µS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic single point, with six standard solutions (84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 9999 ppm (mg\/L); 0 to 400, 000 ppm (mg\/L) (maximum value depends on TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003emanual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L); auto-ranging: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L); auto-ranging (fixed ppt):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003edependent on resistivity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 K, 0.01 °C, 0.01 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15 °C; ±0.27 °F; ±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 55 °C (23 to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e45,000 records (continuous logging or log-on-demand of all parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Interval\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB to PC with HI9298194 Hanna software installed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 360 hours of continuous use without backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981954 is supplied with HI7698195 multiparameter probe, HI7698194-1 pH\/ORP sensor, HI7698194-3 EC\/TDS\/Salinity\/Resistivity sensor, HI9828-20 quick calibration solution (230 mL), HI7698295 protective probe shield, HI76981952 probe maintenance kit, HI7698290 calibration beaker, HI920015 micro USB cable, 1.5V AAA batteries (4 pcs.), instrument quality certificate, probe quality certificate, and instruction manual packaged in a rugged thermoformed carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981954\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Multiparameter Waterproof Portable pH\/ ORP\/EC\/Temperature Meter - HI981954\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871453184369,"sku":"HI981954","price":165650.4,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981954.jpg?v=1792646906"},{"product_id":"pool-line-combo-tds-tester-high-range-hi983024","title":"Pool Line Combo TDS Tester (High Range) - HI983024","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eSlim, ergonomic design that fits comfortably in the hand or pocket\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eTwo-button operation\u003c\/p\u003e\n\u003cp\u003eGraphite sensor reduces polarization effects and does not oxidize\u003c\/p\u003e\n\u003cp\u003eAutomatic calibration at 1382 ppm (mg\/L) with a single push of a button.\u003c\/p\u003e\n\u003cp\u003eAutomatic shut-off with user-controlled settings\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI983024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Combo TDS Tester (High Range) - HI983024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point calibration at 6.44 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic, 0.0 to 50.0 °C(32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eselectable at 8 minutes, 60 minutes or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 Li-ion 3V (1)\/ Approximately 250 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e68 g (2.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI983024 is supplied with HI700384 6.44 ppt TDS standard, 20 mL sachet (1 pc.), Storage \/ Protection cap, CR2032 battery (1 pc.), Instrument quality certificate, and Instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI983024\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Combo TDS Tester (High Range) - HI983024\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871454626161,"sku":"HI983024","price":9038.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi983024.jpg?v=1792646916"},{"product_id":"pool-line-hr-combo-ec-tester-hi983044","title":"Pool Line HR Combo EC Tester - HI983044","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eSlim, ergonomic design that fits comfortably in the hand or pocket\u003c\/p\u003e\n\u003cp\u003eGraphite sensor reduces polarization effects and does not oxidize\u003c\/p\u003e\n\u003cp\u003eAmperometric conductivity sensor and temperature measurements in one probe\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eBEPS (Battery Error Prevention System) with battery % level displayed at startup\u003c\/p\u003e\n\u003cp\u003eAutomatic shut-off with three user controlled settings\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI983044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line High-Range Combo EC Tester - HI983044\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point calibration at 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic, 0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eselectable at 8 minutes, 60 minutes or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 Li-ion 3V (1)\/ Approximately 250 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e68 g (2.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI983044\" target=\"_blank\" rel=\"noopener\"\u003ePool Line High-Range Combo EC Tester - HI983044\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871454953841,"sku":"HI983044","price":9038.25,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi983044.jpg?v=1792646919"},{"product_id":"pool-line-ec-tds-tester-high-range-hi983124","title":"Pool Line EC\/TDS Tester (High Range) - HI983124","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eUser selected EC to TDS conversion factor from 0.45 or 1.00\u003c\/p\u003e\n\u003cp\u003eUser selected temperature compensation coefficient β (BETA)\u003c\/p\u003e\n\u003cp\u003eReplaceable, amperometric, graphite EC\/TDS sensor\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC) displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eBattery Error Prevention System (BEPS) with battery % level displayed at startup\u003c\/p\u003e\n\u003cp\u003eAuto-off feature automatically shuts off the meter after 8 minutes of non-use to maximize battery life\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI983124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line EC\/TDS Tester (High Range) - HI983124\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRango CE\u003c\/td\u003e\n\u003ctd\u003e0.00 a 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolución CE\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExactitud CE\u003c\/td\u003e\n\u003ctd\u003e±2% de la escala completa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibración CE\u003c\/td\u003e\n\u003ctd\u003ecalibración automática de un punto a 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRango TDS\u003c\/td\u003e\n\u003ctd\u003e0.00 a 10.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolución TDS\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExactitud TDS\u003c\/td\u003e\n\u003ctd\u003e±2% de la escala completa\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibración TDS\u003c\/td\u003e\n\u003ctd\u003ecalibración automática de un punto a 6.44 ppt (usando un factor de conversión de 0.5)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompensación de Temperatura CE\/TDS\u003c\/td\u003e\n\u003ctd\u003eAutomática CE\/TDS: ß=0.0 a 2.4% \/ ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFactor de Conversión de CE a TDS\u003c\/td\u003e\n\u003ctd\u003e0.45 a 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRango de Temperatura\u003c\/td\u003e\n\u003ctd\u003e0.0 a 60.0 °C (32.0 a 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolución de Temperatura\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrecisión de Temperatura\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrodo de pH\u003c\/td\u003e\n\u003ctd\u003eHI73311\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eApagado Automático\u003c\/td\u003e\n\u003ctd\u003eApagado Automático\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo de Batería\/Duración\u003c\/td\u003e\n\u003ctd\u003e1.5V (4)\/ Aproximadamente 100 horas\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmbiente\u003c\/td\u003e\n\u003ctd\u003e0 a 50 °C (32 a 122 °F); HR 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensiones\u003c\/td\u003e\n\u003ctd\u003e171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeso\u003c\/td\u003e\n\u003ctd\u003e85 g (3.1 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInformación Sobre Pedidos\u003c\/td\u003e\n\u003ctd\u003eEl HI983124 se suministra con estándar de conductividad de 12880 µS\/cm HI700304, sobre de 20 mL (3 piezas), estándar de TDS de 6.44 ppt HI700384, sobre de 20 mL (3 piezas), electrodo de CE\/TDS HI73311, herramienta de extracción de electrodos HI73128, tapa de almacenamiento\/protección, pilas de 1.5 V (4 uds.), certificado de calidad del instrumento y manual de instrucciones.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI983124\" target=\"_blank\" rel=\"noopener\"\u003ePool Line EC\/TDS Tester (High Range) - HI983124\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871455019377,"sku":"HI983124","price":13385.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi983124.jpg?v=1792646921"},{"product_id":"pool-line-digital-thermometer-hi985394","title":"Pool Line Digital Thermometer - HI985394","description":"\u003cp\u003eThe Checktemp Digital Thermometer is a high-accuracy NTC thermistor thermometer connected to a weighted, stainless steel probe by a 3 m (9.9’) flexible, silicone cable.\u003c\/p\u003e\n\u003cp\u003eThe weighted, stainless steel probe is designed to measure temperature in swimming pools and hot tubs. Attached to the meter by 3 m of cable, the probe is capable of taking temperature readings at various depths. The probe is made of AISI 316 stainless steel, which makes it easy to clean.\u003c\/p\u003e\n\u003cp\u003eThe HI985394 Pool Line Digital Thermometer is equipped with Hanna’s exclusive CAL Check® feature for reliable and accurate measurements. CAL Check automatically runs a self-check upon startup and looks for any drift in the internal electronics. The thermometer then reports the instruments status back to the user in a matter of seconds; 0 for ok and Err if something is wrong.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAISI 316 stainless steel weighted probe\u003c\/li\u003e\n\u003cli\u003e±0.3℃ (±0.5℉) Accuracy\u003c\/li\u003e\n\u003cli\u003eCAL Check™ - Automatically verifies calibration at startup\u003c\/li\u003e\n\u003cli\u003e℃\/℉ readout – User selectable\u003c\/li\u003e\n\u003cli\u003eIP 65 water resistant protection\u003c\/li\u003e\n\u003cli\u003eUser-selectable auto-off (select from 8 min., 60 min., or disable)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI985394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Digital Thermometer - HI985394\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 80.0°C (-4.0 to 176.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3°C (±0.5°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eWeighted stainless steel probe with silicone cable (3 m \/ 9.9’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e8 minutes (default), 60 minutes, or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA alkaline (3) \/ approximately 2 years of use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-30 to 50°C (-22 to 122 °F); IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e107 x 59 x 17 mm (4.2 x 2.3 x 0.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e109 g (3.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI985394 Pool Line Digital Thermometer is supplied with an attached weighted stainless-steel probe to a 3 m (9.9’) silicone cable, 1.5 V AAA batteries (3 pcs.), instrument quality certificate, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI985394\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Digital Thermometer - HI985394\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871456592241,"sku":"HI985394","price":9481.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi985394.jpg?v=1792646928"},{"product_id":"pool-line-ph-checker-hc-hi779","title":"Pool Line pH Checker® HC - HI779","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"HI782 Checker use\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe HI779 Pocket Colorimeter from the Pool Line Series is designed to measure pH in swimming pools, hot tubs and spas, on a scale between 6.3 and 8.6 pH. HI779 follows the same principle as chemical test kits and swimming pool litmus papers, but with one key advantage. The value is in fact determined electronically, thanks to a light source and a photodetector, which precisely detect the color produced by the reaction of the sample with phenol red. So you no longer have to guess what color the sample is to determine the pH. The instrument offers extremely greater sensitivity than the human eye and can detect pH values with resolution down to 0.1 pH.\u003c\/p\u003e\n\u003cp\u003eThe shape of the tool fits perfectly in your palm and pocket, and the large LCD display is easy to read. The automatic shut-off function ensures long battery life.\u003c\/p\u003e\n\u003cp\u003eTo take a measurement, fill a cuvette with a water sample, place it in the instrument and zero the Checker®. Next, add the reagent, which will react with the hydrogen ion, causing a color change. Finally, place the vial in the Checker®, press the button and read the results. It's that easy!\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI779\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line pH Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI779\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e6.3 to 8.6 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 pH of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Phenol Red Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 10 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI779 Checker HC is supplied with sample cuvettes with caps (2 pcs.), pH starter reagent kit, 1.5VAAA battery (1 pc.), and instruction manual packaged in a plastic carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI779\" target=\"_blank\" rel=\"noopener\"\u003ePool Line pH Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI779\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871457345905,"sku":"HI779","price":6808.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi779_front-720x720-9a686fb6-91ba-466c-a0b4-44106789affa.png?v=1792646940"},{"product_id":"pool-line-ph-checker-hc-reagents-100-tests-hi779-25","title":"Pool Line pH Checker HC Reagents (100 Tests) – HI779-25","description":"\u003cp\u003eHI779-25 sono reagenti di alta qualità,  che assicurano agli utenti di ottenere misurazioni rapide e accurate con con il Checker® HC HI779. Questi reagenti seguono il metodo Rosso Fenolo in cui il reagente produce un cambiamento di colore nel campione,  legato al valore di pH. Aggiungendo semplicemente 5 gocce di reagente HI779-25 al campione,  avverrà la reazione e HI779 determinerà la concentrazione sulla base del colore prodotto,  che può variare tra tonalità del giallo o rosso. I risultati verranno visualizzati in pH con risoluzione 0.1 pH. La confezione di reagenti HI779-25 consente di effettuare 100 analisi.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI779-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line pH Checker HC Reagents (100 Tests) – HI779-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of Phenol Red Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI779-25\"\u003ePool Line pH Checker HC Reagents (100 Tests) – HI779-25\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871457411441,"sku":"HI779-25","price":2184.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi779-25_box-720x720-feb4593e-0401-4534-8edc-ade76375ed40.png?v=1792646941"},{"product_id":"pool-line-free-chlorine-checker-hc-hi7014","title":"Pool Line Free Chlorine Checker® HC - HI7014","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/How-to-use-a-Hanna-Checker.jpg\" alt=\"How to use a Hanna Checker\" width=\"800\" height=\"597\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eChlorine is a strong oxidizing agent that is used to keep bodies of water safe from bacterial contamination. Free Chlorine in a swimming pool is usually kept between 1 and 3 ppm (mg\/L).\u003c\/p\u003e\n\u003cp\u003eCombined chlorine is the quantity of chlorine that has combined with nitrogen containing compounds. It is much less effective as a disinfectant than free chlorine. Total chlorine is a measurement of both combined chlorine and free chlorine. Ideally there is a balance between free and total chlorine which means that the combined chlorine levels are near zero. The presence of chloramines is undesirable because of the distinctive “swimming pool smell” as well as irritation to the eyes and mucous membranes caused by combined chlorines like dichloramines.\u003c\/p\u003e\n\u003cp\u003eHI7014 Pool Line Checker® Handheld Colorimeter is designed for the measurement of free chlorine in swimming pools, hot tubs, and spas. The contoured style of the Checker fits in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of this Checker fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eTo perform a measurement the instrument a water sample is placed into a cuvette and the meter is zeroed. Next, a reagent is added that will react with free chlorine to produce a pink color. Last, place the vial into the Checker, press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Free Chlorine Checker® HC - HI7014\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ± 3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of US EPA Method 330.5. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 2 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7014 Checker HC is supplied with sample cuvettes with caps (2), free chlorine starter reagent kit for 6 tests, 1.5VAAA battery (1), and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7014\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Free Chlorine Checker® HC - HI7014\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458820465,"sku":"HI7014","price":8600.85,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Hanna-Pool-Line-Checker-HI7014-Front-scaled.jpg?v=1792646954"},{"product_id":"pool-line-copper-high-range-checker-hi7024","title":"Pool Line Copper High Range Checker - HI7024","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/How-to-use-a-Hanna-Checker.jpg\" alt=\"How to use a Hanna Checker\" width=\"800\" height=\"597\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eIn certain regions Copper can be found naturally in groundwater. Copper can also found in small amounts in the drinking water supplied by a municipality. Other sources of copper include any corrosion from piping and heat exchangers. Copper is normally not a concern but with pools the level can build up as water is evaporated and replaced. High levels of copper are undesirable in swimming pools, hot tubs, and spas, as it can stain bathing suits, hair, and other surfaces green. It can also cause the water to have an undesirable color when high levels of chlorine are present.\u003c\/p\u003e\n\u003cp\u003eHI7024 Pool Line Checker Handheld Colorimeter is designed for the measurement of copper in swimming pools, hot tubs, and spas. The contoured style of the Checker fits in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eTo perform a measurement with the instrument a water sample is placed into a cuvette and the meter is zeroed. Next, a reagent is added that will react with the copper in the water sample. Last, place the vial into the Checker, press the button and read the results. It’s that easy.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Copper High Range Checker - HI7024\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 ppm (as Cu2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 ppm ±5% of reading @ 25 °C (77 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eFactory calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA Alkaline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7024\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Copper High Range Checker - HI7024\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7024 Pool Line Copper Checker HC is supplied with sample cuvette and cap (2 pcs. each), copper high range reagent starter kit (6 tests), 1.5 V AAA battery (1 pc.), and instruction manual packaged in a plastic carrying case.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458853233,"sku":"HI7024","price":7014.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7024_Front-3266x3266-6be22078-8a24-4dc2-a9cc-a52f74d71431-scaled.jpg?v=1792646954"},{"product_id":"pool-line-free-chlorine-checker-hc-calibration-check-set-0-00-and-1-00-ppm-free-cl-hi7014-11","title":"Pool Line Free Chlorine Checker  HC® Calibration Check set (0.00 and 1.00 ppm  Free Cl) - HI7014-11","description":"\u003cp\u003eHI7014-11 is a high-quality set of calibration standards that allows users to validate the performance HI7014 Pool Line Free Chlorine Checker® HC. The HI7014-11 includes one sealed cuvette for zero ppm free chlorine and one cuvette that is tinted to an equivalent 1.00 ±0.05 ppm free chlorine sample @ 25°C. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003cp\u003eThe HI7014-11 is supplied with Certificate of Analysis\u003c\/p\u003e\n\u003cp\u003eProduct code\u003c\/p\u003e\n\u003cp\u003eLot number\u003c\/p\u003e\n\u003cp\u003eExpiration date\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7014-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Free Chlorine Checker  HC® Calibration Check set (0.00 and 1.00 ppm  Free Cl) - HI7014-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±3% of reading @ 25 °C (77 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 200 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); max. 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 x 61.0 x 37.5 mm (3.4 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7014-11 is supplied with HI7014-11A - free chlorine certified standard cuvette - A (1), HI701-11B - free chlorine certified standard cuvette – B (1), certificate of analysis, and instruction for use.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7014-11\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Free Chlorine Checker HC® Calibration Check set (0.00 and 1.00 ppm Free Cl)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458951537,"sku":"HI7014-11","price":1674.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7014-11-4437x4437-09821475-8da8-4337-9d89-ca9c924d9e26-scaled.jpg?v=1792646956"}],"url":"https:\/\/hannainst.in\/collections\/industry-pool-spa-and-cold-plunge.oembed","provider":"hanna","version":"1.0","type":"link"}