{"title":"Research","description":"","products":[{"product_id":"marine-salinity-waterproof-tester-hi98319","title":"Marine Salinity Waterproof Tester - HI98319","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eSalinity measurements calculated from a conductivity measurement using known tables\u003c\/p\u003e\n\u003cp\u003eChoice of measurement units displayed in parts per thousand (ppt), Practical Salinity Units (PSU), or specific gravity (S.G.)\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eAmperometric graphite sensor reduces polarization effects and does not oxidize\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eDedicated calibration button with automatic recognition of the 35.00 ppt calibration solution in calibration mode\u003c\/p\u003e\n\u003cp\u003eSupplied complete with meter and calibration sachets in a durable plastic storage case.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Salinity Waterproof Tester - HI98319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 70.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1 ppt for 0.0 to 40.0 ppt; ±2 ppt for readings over 40.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003eall ranges calibrated with 35.00 ppt salinity standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 70.0 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 PSU for 0.0 to 40.0 PSU ; ±2 PSU for readings over 40.0 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Range\u003c\/td\u003e\n\u003ctd\u003e1.000 to 1.041 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.001 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5.0 to 50.0°C (41.0 to 122.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Method\u003c\/td\u003e\n\u003ctd\u003eppt - International Oceanographic Tables, 1966\nPSU - Standard Methods for the Examination of Water and Wastewater, 2520 B, Electrical Conductivity Method\nStandard Methods for the Examination of Water and Wastewater, 2520 C, Density Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C; 32.0 to 122.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C; ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable 8 minutes, 60 minutes, or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 3V lithium ion \/ approximately 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e68 g (2.4 oz.) without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98319 is supplied with protective cap, 35.00 ppt calibration solution sachet (4), CR2032 battery (1), plastic storage case, instrument quality certificate and instructional manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98319\" target=\"_blank\" rel=\"noopener\"\u003eMarine Salinity Waterproof Tester - HI98319\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871121965425,"sku":"HI98319","price":9363.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98319-angle-c.jpg?v=1792645678"},{"product_id":"waterproof-portable-ec-tds-resistivity-salinity-meter-hi98192","title":"Waterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.\u003c\/p\u003e\n\u003cp\u003eHI98192 has an expanded conductivity range from 0.000 µS\/cm to 1000 mS\/cm actual conductivity (400 mS\/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.\u003c\/p\u003e\n\u003cp\u003eHI98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.\u003c\/p\u003e\n\u003cp\u003eChoose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.\u003c\/p\u003e\n\u003ch5\u003eEC and TDS measurements are fully customizable and include:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eCell constant selection between 0.0 and 10.000\u003c\/li\u003e\n\u003cli\u003eSelection of linear or non-linear (natural water), or No temperature compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe temperature compensation coefficient range is configurable from 0.00 to 10.00%\/℃ with a choice of reference temperatures of 15℃, 20℃ and 25℃. The conductivity to TDS factor is adjustable from 0.40 and 1.00.\u003c\/p\u003e\n\u003cp\u003eThe HI98192 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.\u003c\/p\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.\u003c\/p\u003e\n\u003cp\u003eGLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.\u003c\/p\u003e\n\u003cp\u003eAccess help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.\u003c\/p\u003e\n\u003cp\u003eThe compact, durable HI720192 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter, probe, beakers and conductivity standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-1.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThree stages of conformity\u003c\/strong\u003e\nPerforms all 3 stages of USP water quality testing requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-2-guide.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eOn-screen guide\u003c\/strong\u003e\nUsers are provided with on-screen instructions for each USP stage\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-2-progress.jpg\" alt=\"USP 2 progress\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProgress bar\u003c\/strong\u003e\nDisplays progress towards meeting stage 2 stability requirements.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eCompact, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003eMethods\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eUSP \u0026lt;645\u0026gt; capable for checking the quality of water used in pharmaceutical manufacturing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eSalinity readings\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eSeawater salinity can be displayed as % NaCl, natural seawater scale (ppt) or practical salinity scale (PSU)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-ranging and fixed range options\u003c\/h5\u003e\n\u003ch5\u003eCalibration\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePerform up to a five point calibration for enhanced accuracy\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP Features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data provides calibration data including date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eAuto Hold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes first stable reading on the display\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003eTemperature compensation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eNo temperature compensation, linear temperature compensation and non-linear temperature compensation – ISO\/DIN 7888\u003c\/li\u003e\n\u003cli\u003eConfigurable linear temperature compensation coefficient range from 0.00 to 10.00%\/℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLog on Demand: Store measurement data at the press of a button\u003c\/li\u003e\n\u003cli\u003eInterval lot logging: Log measurements at a selectable interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via opto-isolated USB with optional HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003e100-hour battery life\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eApproximately 100 hours of continuous use (without backlight)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, Graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Environmental, pharmaceutical, plating, water treatment, food manufacturing, and water and wastewater\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/l18xilr9j4?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/b47438229e5b7d8641acbd496846c11c50147bcf.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWaterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 µS\/cm*; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm (actual conductivity; temperature compensated to 400 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.01 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic up to five points with seven memorized standards (0.00 µS\/cm, 84.0 µS\/cm, 1.413 mS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g\/L); 10.00 to 99.99 ppt (g\/L); 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm; 0.1 ppm; 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 mg\/L (ppm) or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003enoTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO\/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e15°C, 20°C and 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Multi-range Measurement Modes\u003c\/td\u003e\n\u003ctd\u003eautorange, autoend, lock and fixed range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003emax. one point only in % range (with HI7037 standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 (PSU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 80.00 (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω cm; 100 to 999 Ω cm; 1.00 to 9.99 KΩ cm; 10.0 to 99.9 KΩ cm; 100 to 999 KΩ cm; 1.00 to 9.99 MΩ cm; 10.0 to 100.0 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω cm; 1 Ω cm; 0.01 KΩ cm; 0.1 KΩ cm; 1 KΩ cm; 0.01 MΩ cm; 0.1 MΩ cm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±10 Ω or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2°C; ±0.4°F (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e\n\u003ctd\u003eHI763133, four ring conductivity\/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 100 hours of continuous use (without backlight), 25 hours with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 µS\/cm calibration solution (230 mL), HI7035M 111.8 mS\/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98192\" target=\"_blank\" rel=\"noopener\"\u003eWaterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170396529,"sku":"HI98192","price":103693.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98192_manual_1.jpg?v=1792645815"},{"product_id":"pure-water-tester-0-0-99-9-s-cm-hi98308","title":"Pure Water Tester (0.0 - 99.9 µS\/cm) - HI98308","description":"\u003cp\u003eThe HI98308 features an amperometric graphite electrode that provides better repeatability in measurements since they do not oxidize. An amperometric measurement of EC is based on Ohm's Law, I = V\/R, where R depends on the distance between two pins and their surface. Oxidation changes both the distance and surface, which will affect accuracy. The non-oxidizing graphite pins are able to provide an optimal surface for accurate, dependable results. When calibration is needed, simply submerge the electrode tip into calibration solution and adjust the trimmer on the side of the tester.\u003c\/p\u003e\n\u003cp\u003eThe HI98308 uses a conductometric measurement to determine the purity of water. The HI98308 Pure Water Test (PWT) enables users to check the purity of distilled or demineralized water in laboratory or industrial environments. PWT is suited for fields such as printed circuit board washing, laundry, steam cleaning, checking car battery water and all areas where distilled, demineralized or pure water is used. This tester is housed in durable casing that provides excellent protection against harsh industrial environments.\u003c\/p\u003e\n\u003cp\u003eElectrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges on atomic or larger sized particles in a medium are moved under the influence of a potential difference. EC is a measure of concentration, however, it is non-specic for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na\u003csup\u003e+\u003c\/sup\u003e and Cl-. This is a simplified definition as the measurement is affected by many things such as the type of ionic compound(s) dissolved in the water; the ions mobility, the solution viscosity, temperature as well as concentration.\u003c\/p\u003e\n\u003cp\u003eElectrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. \"Conductance\" and \"Resistance\" depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are \"normalized\" terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna's meters provide these measurements also.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance:\u003c\/h4\u003e\n\u003cp\u003eOne-point calibration\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eCalibrate with 84 µS\/cm EC solution using a screwdriver\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eExposed Temperature Probe\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eFast response to changes in sample temperature\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC)\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eSamples automatically compensated for temperature variations\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eGraphite electrode\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eReduced polarization effects\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePure Water Tester (0.0 - 99.9 µS\/cm) - HI98308\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, one point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 0 to 50°C (32 to 122°F) with β=2%\/°C typical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e175 x 41 x 23 mm (6.9 x 1.6 x 0.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e95 g (3.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98308 is supplied with protective cap, calibration screwdriver (HI98308), batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98308\" target=\"_blank\" rel=\"noopener\"\u003ePure Water Tester (0.0 - 99.9 µS\/cm) - HI98308\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170462065,"sku":"HI98308","price":8601.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98308-pwt_1.jpg?v=1792645815"},{"product_id":"professional-waterproof-portable-ph-orp-ise-meter-hi98191","title":"Professional Waterproof Portable pH\/ORP\/ISE Meter - HI98191","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eFor the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable.\u003c\/p\u003e\n\u003cp\u003eHanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.\u003c\/p\u003e\n\u003cp\u003eThe HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g\/L, ppb, μg\/L, mg\/mL, M, mol\/L, mmol\/L, % w\/v, user defined) and has an expanded measuring range of 1.00 x 10\u003csup\u003e-7\u003c\/sup\u003e to 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e.\u003c\/p\u003e\n\u003cp\u003ePressing the \"AutoHold\" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An \"out of calibration range\" warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.\u003c\/p\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna's HI920015 micro USB cable and HI92000 software.\u003c\/p\u003e\n\u003cp\u003eAccess help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.\u003c\/p\u003e\n\u003cp\u003eThe high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eThe compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eSetup Screen\u003c\/strong\u003e\nOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\npH calibration features detailed CAL Check™ messages. Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGLP\u003c\/strong\u003e\nComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-ISE-Fluoride.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eISE Measurements\u003c\/strong\u003e\nThe HI98191 includes ISE measurements when used with our wide selection of ISE electrodes or a custom version.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003epH CAL Check™\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/li\u003e\n\u003cli\u003eDisplays overall probe condition based on offset and slope after calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eISE direct concentration readout in a choice of concentration units\u003c\/h5\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003ch5\u003eFive-point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes a stable reading on the display for recording or logging\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data including date, time, calibrated values, slope and offset (pH)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200-hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Food \u0026amp; Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/1pmzf9o20h?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/2872b8cf233378bfb91dce12e7b14732390aacd8.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eProfessional Waterproof Portable pH\/ORP\/ISE Meter - HI98191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e10¹² Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003efrom 1.00 E⁻⁷ to 9.99 E¹⁰ concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e3 digits 0.01; 0.1; 1; 10 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading (monovalent ions), ±1% of reading (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.8°F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI72911B Titanium body, pH electrode with internal temperature sensor, BNC connector and 1 m (3.3’ cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e300 samples (100 each range pH, mV and ISE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98191 is supplied with HI72911B titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720191 hard carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98191\" target=\"_blank\" rel=\"noopener\"\u003eProfessional Waterproof Portable pH\/ORP\/ISE Meter - HI98191\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871192252785,"sku":"HI98191","price":94938.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98191_manual.jpg?v=1792645854"},{"product_id":"halo-wireless-ph-meter-with-microbulb-hi10832","title":"HALO® Wireless pH Meter with Microbulb  - HI10832","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eDownload the FREE app and try before you buy!\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.hannainst.hannalab\u0026amp;hl=en\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Google.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/itunes.apple.com\/us\/app\/hanna-lab\/id913755813?ls=1\u0026amp;mt=8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Apple.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI13302_Angle_2017_720x720_72_RGB.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe HALO® Wireless pH Meter with Microbulb incorporates Bluetooth® Smart technology with an application-specific design featuring and ultra-tiny glass sensing bulb. There are several features that make it ideal for measuring the pH in vials,  test tubes,  and smaller vessel applications.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_bulb.png\" alt=\"Micro bulb Tip\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMicro Bulb Tip\u003c\/h4\u003e\n\u003cp\u003eThe 3 mm micro bulb tip design allows for measurement in samples less than 100 µL. HI10832 is ideal for samples that need to be measured in test tubes,  vials,  and 96 well plates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_GP_glass.png\" alt=\"GP glass\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGeneral Purpose Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eGeneral Purpose (GP) glass is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples from -5 to 50℃ (23 to 122℉).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_bulb.png\" alt=\"HI10832 \" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSpheric Glass Tip\u003c\/h4\u003e\n\u003cp\u003eThe spheric bulb is for general purpose use within laboratory environments and applications that measure aqueous solutions due to its large surface area. Other tip shapes are available including flat tip for surface measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eHanna Lab App\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes can connect with HI2202 edge\u003csup\u003eblu\u003c\/sup\u003e meter or a compatible Apple or Android device running the Hanna Lab App.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Android-Compatible.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe Hanna Lab App turns a compatible Apple or Android device into a full-featured pH meter when used with the Hanna HALO pH probe with Bluetooth Smart technology. Functions include calibration,  measurement,  data logging,  graphing and data sharing. Measurement and logging of pH and temperature at one second intervals start as soon as the probe is connected. Measurements can be displayed alone on the display,  with tabulated data,  or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/calibration.png\" alt=\"\" width=\"331\" height=\"331\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFive-Point Calibration\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App incorporates a probe calibration using up to five pH buffers that are automatically recognized and temperature corrected to 25.0℃ during calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo2.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReal-Time Data\u003c\/h4\u003e\n\u003cp\u003eDisplay of pH and temperature updated every second. Readings are automatically saved to a history file every hour,  limited only by the available memory on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo3.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFluid,  Dynamic Graphing\u003c\/h4\u003e\n\u003cp\u003eMeasurement can be displayed with tabulated data or a graph on the display. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11312hand.jpg\" alt=\"HALO pH probe features\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eConnecting the HALO probe to the Hanna Lab App is simple. Tap the Bluetooth icon in the top-right corner to view all available HALO probes then press the button on your HALO probe. Select the newly discovered HALO probe from the list of available probes. If a previously associated probe is in discovery mode when the app is opened it will connect to that probe automatically.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/appenabledthm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP (Good Laboratory Practice)\u003c\/h4\u003e\n\u003cp\u003eDisplays date and time of current calibration,  probe offset,  and average slope,  along with calibrated buffers,  mV values,  temperature and slopes between each buffer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-alarm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-share.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog \u0026amp; Share Data\u003c\/h4\u003e\n\u003cp\u003eSaved log files may be annotated with measurement specific information. Data is easily shared via email in CSV format.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-help.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp \u0026amp; Tutorials\u003c\/h4\u003e\n\u003cp\u003eDemo probe mode helps you explore features of the Hanna Lab App. General app information,  General HALO information,  pH tutorial,  maintenance tutorial,  and contact information are available in help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHanna Lab App Features\/Benefits:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConnects to HALO electrodes via Bluetooth Smart Technology (Bluetooth 4.0)\u003cbr\u003e\u003cbr\u003eUp to five-point pH calibration with seven standard pH buffers available\u003cbr\u003e\u003cbr\u003eCalibration reminder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eAlerts you when HALO needs calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eReal-time data\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays pH and temperature updated every second\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBasic GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration along with probe offset and average slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFull GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFluid,  dynamic graphing\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using the pinch-to-zoom technology for enhanced  viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMeasurement alarms\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts you if the measurement threshold is exceeded\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne button sample tagging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePressing either the probe icon in the Hanna Lab App or button on the HALO pH probe will tag sample data for easy reference\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eData-logging with custom annotations\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSaved log files may be annotated with measurement  specific  information\u003c\/li\u003e\n\u003cli\u003eData is autosaved every hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFour ways to save and share data:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll data since last autosave\u003c\/li\u003e\n\u003cli\u003eAnnotations only\u003c\/li\u003e\n\u003cli\u003eAll data within a timed interval\u003c\/li\u003e\n\u003cli\u003eAnnotations only within a timed interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eShare data via email in CSV format\u003cbr\u003e\u003cbr\u003e Help and tutorials:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDemo probe mode to help explore features of the Hanna Lab App\u003c\/li\u003e\n\u003cli\u003eGeneral app information\u003c\/li\u003e\n\u003cli\u003eGeneral HALO information\u003c\/li\u003e\n\u003cli\u003epH tutorial\u003c\/li\u003e\n\u003cli\u003eMaintenance tutorial\u003c\/li\u003e\n\u003cli\u003eContact information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility:\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes are compatible with HI2202 edgeblu meter and the following devices: \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eAndroid\u003c\/strong\u003e\u003cbr\u003e Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eiOS\u003c\/strong\u003e\u003cbr\u003e iPad (3rd generation or newer)\u003cbr\u003e iPhone (4S or newer)\u003cbr\u003e iPod Touch (5th generation or newer)\u003cbr\u003e \u003cbr\u003e Information about which products have Bluetooth Smart Technology (4.0),  also known as low energy (LE),  can be found \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/List_of_iOS_devices\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/v1yd9ivxgc?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/40e78888f8bf4b55edc940174475d319898347de.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI10832\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HALO\u003csup\u003e®\u003c\/sup\u003e Wireless pH Meter with Microbulb  - HI10832\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e single, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e open junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e viscolene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd\u003e viscolene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e general purpose (GP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e spherical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e  pH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F) - GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 163.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e No.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e Bluetooth Smart (Bluetooth 4.0), 10 m (33') range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e CR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e test tubes, vials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e -2.000 to 16.000 pH \u003cbr\u003e ±800 mV\u003cbr\u003e -20.0 to 120.0 ºC *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1, 0.01, 0.001 pH \u003cbr\u003e 1, 0.1 mV\u003cbr\u003e0.1 ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e ±0.005 pH \u003cbr\u003e ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e Up to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffers\u003c\/td\u003e\n\u003ctd\u003e 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from -5.0 to 100.0 ºC \/ 23.0 to 212.0 ºF *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\/System Requirements\u003c\/td\u003e\n\u003ctd\u003e  Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownload Information\u003c\/td\u003e\n\u003ctd\u003e Hanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI10832 (HALO) is supplied with storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, battery, quality certificate and instruction sheet. Smartphone and tablet not included.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI10832\"\u003eHALO\u003csup\u003e®\u003c\/sup\u003e Wireless pH Meter with Microbulb - HI10832\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871197790577,"sku":"HI10832","price":48523.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-dynamic-graphing-ipad-screen-hanna-lab-app_8.jpg?v=1792645864"},{"product_id":"halo-pei-body-gel-filled-ph-electrode-with-bluetooth-hi12302","title":"HALO® PEI Body Gel Filled pH Electrode with Bluetooth® - HI12302","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eDownload the FREE app and try before you buy!\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.hannainst.hannalab\u0026amp;hl=en\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Google.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/itunes.apple.com\/us\/app\/hanna-lab\/id913755813?ls=1\u0026amp;mt=8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Apple.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI12302family.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe HI12302 HALO is a revolutionary pH electrode that incorporates Bluetooth Smart (Bluetooth 4.0) wireless technology with an application-specific design. This electrode has many features that makes it ideal for use in the field or on the production floor. These features include Low Temperature (LT) glass,  spheric bulb,  integrated temperature sensor,  PEI body,  and double reference junction with silver-free gel electrolyte.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI12302_SphericTip.png\" alt=\"Speric Tip\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSpheric Glass Tip\u003c\/h5\u003e\n\u003cp\u003eThe spheric bulb is for general purpose use within laboratory environments and applications that measure aqueous solutions due to its large surface area. Other tip shapes include conic for penetration and flat tip for surface measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI12302_GPGlass.png\" alt=\"temperature sensor\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eBuilt-In Temperature Sensor\u003c\/h5\u003e\n\u003cp\u003eHI12302 features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode. A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in order to compensate for the effect that temperature has on the membrane potential as predicted by the Nernst equation. By having an accurate reading it is possible to provide a temperature compensated reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI12302_body.jpg\" alt=\"pH electrode\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI12302_PEIBody.png\" alt=\"pei body\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003ePEI Body\u003c\/h5\u003e\n\u003cp\u003eThe body of the HI12302 is composed of polyetherimide (PEI) resin. PEI is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. PEI is a high quality plastic that is chemically resistant to many aggressive chemicals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI12302_CeramicJunction.png\" alt=\"single ceramic double junction reference\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSingle Ceramic Double Junction Reference\u003c\/h5\u003e\n\u003cp\u003eThe HI12302 is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction also known as a salt bridge is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer portion of the reference cell has a single ceramic frit. A single ceramic junction allows the gel electrolyte to flow at a rate of 15 to 20 µL\/hour.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/electrode_fill_solutions_comparison.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eConventional electrodes are normally single junction. As depicted by the figure above,  these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions,  such as high pressure,  high temperature,  highly acidic or alkaline solutions,  the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked,  the reference electrode can become contaminated,  leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample,  some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.\u003c\/p\u003e\n\u003cp\u003eHanna’s double junction system,  as the name implies,  has two junctions,  only one of which is in contact with the sample as shown in the figure. Under adverse conditions,  the same tendency of sample ingress is evident. However,  as the reference electrode system is separated physically from the intermediate electrolyte area,  the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free.” Since there is no silver present,  there is no precipitate that can form to clog the junction.\u003c\/p\u003e\n\u003ch2\u003eHanna Lab App\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes can connect with HI2202 edge\u003csup\u003eblu\u003c\/sup\u003e meter or a compatible Apple or Android device running the Hanna Lab App.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Android-Compatible.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe Hanna Lab App turns a compatible Apple or Android device into a full-featured pH meter when used with the Hanna HALO pH probe with Bluetooth Smart technology. Functions include calibration,  measurement,  data logging,  graphing and data sharing. Measurement and logging of pH and temperature at one second intervals start as soon as the probe is connected. Measurements can be displayed alone on the display,  with tabulated data,  or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/calibration.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFive-Point Calibration\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App incorporates a probe calibration using up to five pH buffers that are automatically recognized and temperature corrected to 25.0℃ during calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo2.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReal-Time Data\u003c\/h4\u003e\n\u003cp\u003eDisplay of pH and temperature updated every second. Readings are automatically saved to a history file every hour,  limited only by the available memory on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo3.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFluid,  Dynamic Graphing\u003c\/h4\u003e\n\u003cp\u003eMeasurement can be displayed with tabulated data or a graph on the display. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI12302hand.png\" alt=\"HALO pH probe features\" width=\"622\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eConnecting the HALO probe to the Hanna Lab App is simple. Tap the Bluetooth icon in the top-right corner to view all available HALO probes then press the button on your HALO probe. Select the newly discovered HALO probe from the list of available probes. If a previously associated probe is in discovery mode when the app is opened it will connect to that probe automatically.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/appenabledthm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP (Good Laboratory Practice)\u003c\/h4\u003e\n\u003cp\u003eDisplays date and time of current calibration,  probe offset,  and average slope,  along with calibrated buffers,  mV values,  temperature and slopes between each buffer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-alarm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-share.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog \u0026amp; Share Data\u003c\/h4\u003e\n\u003cp\u003eSaved log files may be annotated with measurement specific information. Data is easily shared via email in CSV format.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-help.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp \u0026amp; Tutorials\u003c\/h4\u003e\n\u003cp\u003e\u0026gt;Demo probe mode helps you explore features of the Hanna Lab App. General app information,  General HALO information,  pH tutorial,  maintenance tutorial,  and contact information are available in help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHanna Lab App Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eConnects to HALO electrodes via Bluetooth Smart Technology (Bluetooth 4.0)\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eUp to five-point pH calibration with seven standard pH buffers available\u003c\/strong\u003e \u003cbr\u003e\u003cstrong\u003eCalibration reminder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eAlerts you when HALO needs calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eReal-time data\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays pH and temperature updated every second\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBasic GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration along with probe offset and average slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFull GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration,  probe offset and average slope along with calibrated buffers,  mV values,  temperature and slopes between each buffer\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFluid, dynamic graphing\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMeasurement alarms\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts you if the measurement threshold is exceeded\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne button sample tagging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePressing either the probe icon in the Hanna Lab App or button on the HALO pH probe will tag sample data for easy reference\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eData-logging with custom annotations\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSaved log files may be annotated with measurement  specific  information\u003c\/li\u003e\n\u003cli\u003eData is autosaved every hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFour ways to save and share data:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll data since last autosave\u003c\/li\u003e\n\u003cli\u003eAnnotations only\u003c\/li\u003e\n\u003cli\u003eAll data within a timed interval\u003c\/li\u003e\n\u003cli\u003eAnnotations only within a timed interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eShare data via email in CSV format\u003cbr\u003e\u003cbr\u003e Help and tutorials:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDemo probe mode to help explore features of the Hanna Lab App\u003c\/li\u003e\n\u003cli\u003eGeneral app information\u003c\/li\u003e\n\u003cli\u003eGeneral HALO information\u003c\/li\u003e\n\u003cli\u003epH tutorial\u003c\/li\u003e\n\u003cli\u003eMaintenance tutorial\u003c\/li\u003e\n\u003cli\u003eContact information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility:\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes are compatible with HI2202 edgeblu meter and the following devices: \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eAndroid\u003c\/strong\u003e\u003cbr\u003e Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eiOS\u003c\/strong\u003e\u003cbr\u003e iPad (3rd generation or newer)\u003cbr\u003e iPhone (4S or newer)\u003cbr\u003e iPod Touch (5th generation or newer)\u003cbr\u003e \u003cbr\u003e Information about which products have Bluetooth Smart Technology (4.0),  also known as low energy (LE),  can be found \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/List_of_iOS_devices\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/v1yd9ivxgc?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/40e78888f8bf4b55edc940174475d319898347de.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI12302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HALO\u003csup\u003e®\u003c\/sup\u003e PEI Body Gel Filled pH Electrode with Bluetooth\u003csup\u003e®\u003c\/sup\u003e - HI12302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e pH: 0 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e ceramic, single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e spheric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e -5 to 70°C (23 to 158°F) - LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 100 mm \/ 165 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e Bluetooth Smart (Bluetooth 4.0), 10 m (33') range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e CR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e field applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Environment: 0.0 to 50.0°C (32.0 to 122.0°F), electronic module is not waterproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e -2.000 to 16.000 pH \/ ±800 mV \/ -20.0 to 120.0 ºC *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1, 0.01, 0.001 pH \/ 1, 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e ±0.005 pH \/ ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e Up to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffers\u003c\/td\u003e\n\u003ctd\u003e 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e Automatic from -5.0 to 100.0 ºC \/ 23.0 to 212.0 ºF *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\/System Requirements\u003c\/td\u003e\n\u003ctd\u003e Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownload Information\u003c\/td\u003e\n\u003ctd\u003e Hanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI12302 (HALO) is supplied with storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, battery, quality certificate and instruction sheet.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI12302\"\u003eHALO\u003csup\u003e®\u003c\/sup\u003e PEI Body Gel Filled pH Electrode with Bluetooth\u003csup\u003e®\u003c\/sup\u003e - HI12302\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871206834545,"sku":"HI12302","price":20840.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi12302_front_2017.jpg?v=1792645875"},{"product_id":"halo-bluetooth-wireless-soil-ph-electrode-hi12922","title":"HALO®  Bluetooth® Wireless Soil pH Electrode - HI12922","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eDownload the FREE app and try before you buy!\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.hannainst.hannalab\u0026amp;hl=en\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Google.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/itunes.apple.com\/us\/app\/hanna-lab\/id913755813?ls=1\u0026amp;mt=8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Apple.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Conical-HALO_Angle2_HI12922.jpg\" alt=\"HALO - Soil pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe HALO® Wireless Soil pH Meter incorporates Bluetooth® Smart technology with an application-specific design. There are several features that make it ideal for measuring the pH of soil.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/glass-body.png\" alt=\"Low Temperature (LT) glass\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLow Temperature Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eLow Temperature (LT) glass Low temperature glass for fast stabilization and more accurate results at lower temperatures.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/triple-ceramic-5dbd0808.png\" alt=\"Triple Ceramic Junction\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eTriple Ceramic Junction\u003c\/h4\u003e\n\u003cp\u003eThe triple ceramic junction allows a higher flow rate of electrolyte from the reference cell into the measurement sample. The increased flow provides greater continuity between the reference electrode and the indicating electrode.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/glass-conical-tip.png\" alt=\"Conical tip \" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConical Glass Tip\u003c\/h4\u003e\n\u003cp\u003eThe conical shaped tip design allows for penetration into solids,  semi-solids,  and emulsions. The HI12922 is ideal for the direct measurement of pH in soil and soil slurries.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-hanna-lab-ipad-iphone.jpg\" alt=\"HALOTM - pH Probe with Bluetooth Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo2.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReal-Time Data\u003c\/h4\u003e\n\u003cp\u003eDisplay of soil pH and temperature updated every second. Readings are automatically saved to a history file every hour,  limited only by the available memory on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo3.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFluid,  Dynamic Graphing\u003c\/h4\u003e\n\u003cp\u003eMeasurements can be displayed alone on the display,  with tabulated data,  or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/appenabledthm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP (Good Laboratory Practice)\u003c\/h4\u003e\n\u003cp\u003eDisplays date and time of current calibration,  offset,  and average slope,  along with calibrated buffers,  mV values,  temperature and slopes between each buffer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11312hand.jpg\" alt=\"HALO pH probe features\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-alarm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-share.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog \u0026amp; Share Data\u003c\/h4\u003e\n\u003cp\u003eSaved log files may be annotated with measurement-specific information. Data is easily shared via email in CSV format.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-help.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp \u0026amp; Tutorials\u003c\/h4\u003e\n\u003cp\u003eDemo mode helps you explore features of the Hanna Lab App. General app information,  HALO information,  pH tutorial,  maintenance tutorial,  and contact information are available in help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHALO Features\/Benefits:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConnects to Hanna Lab App with a compatible Apple or Android Device via Bluetooth Smart Technology (Bluetooth 4.0)\u003cbr\u003e\u003c\/strong\u003e \u003cbr\u003e\u003cstrong\u003eUp to five-point pH calibration with seven standard pH buffers available\u003c\/strong\u003e \u003cbr\u003e\u003cstrong\u003eCalibration reminder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts you when HALO pH meter for beer needs calibration\u003c\/li\u003e\n\u003cli\u003eAppropriate preprogrammed calibration buffer set for application specific Halo pH electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eReal-time data\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays pH and temperature updated every second\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBasic Good Laboratory Practice (GLP)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration along with offset and average slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFull GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration,  offset and average slope along with calibrated buffers,  mV values,  temperature and slopes between each buffer\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFluid,  dynamic graphing\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMeasurement alarms\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts you if the measurement threshold is exceeded\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne button sample tagging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePressing either the icon in the Hanna Lab App or button on the HALO will tag sample data for easy reference\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eData logging with custom annotations\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSaved log files may be annotated with measurement specific information\u003c\/li\u003e\n\u003cli\u003eData is autosaved every hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFour ways to save and share data:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll data since last autosave\u003c\/li\u003e\n\u003cli\u003eAnnotations only\u003c\/li\u003e\n\u003cli\u003eAll data within a timed interval\u003c\/li\u003e\n\u003cli\u003eAnnotations only within a timed interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eShare data via email in CSV format\u003cbr\u003e\u003cbr\u003eHelp and tutorials:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDemo mode to help explore features of the Hanna Lab App\u003c\/li\u003e\n\u003cli\u003eGeneral app information\u003c\/li\u003e\n\u003cli\u003eGeneral HALO information\u003c\/li\u003e\n\u003cli\u003epH tutorial\u003c\/li\u003e\n\u003cli\u003eMaintenance tutorial\u003c\/li\u003e\n\u003cli\u003eContact information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility:\u003c\/h2\u003e\n\u003ch5\u003eHALO is compatible with the following devices:\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eAndroid\u003c\/strong\u003e\u003cbr\u003eCompatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eiOS\u003c\/strong\u003e\u003cbr\u003eiPad (3rd generation or newer)\u003cbr\u003eiPhone (4S or newer)\u003cbr\u003eiPod Touch (5th generation or newer)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eHI2202 edge\u003csup\u003eblu\u003c\/sup\u003e Meter\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eInformation about which products have Bluetooth Smart Technology (4.0),  also known as low energy (LE),  can be found \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/List_of_iOS_devices\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI12922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HALO\u003csup\u003e®\u003c\/sup\u003e  Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless Soil pH Electrode - HI12922\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e ceramic, triple\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e 3.5M KCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e Low Temperature (LT) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e conic (12 x 12 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 12 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e -5 to 70°C (23 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 195 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e Bluetooth Smart (Bluetooth 4.0), 10 m (33') range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e CR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e Soil \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e  -2.000 to 16.000 pH \u003cbr\u003e ±800 mV \u003cbr\u003e-20.0 to 120.0 ºC *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1, 0.01, 0.001 pH \u003cbr\u003e 1, 0.1 mV\u003cbr\u003e0.1 ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e ±0.005 pH \u003cbr\u003e ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e up to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffers\u003c\/td\u003e\n\u003ctd\u003e 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from -5.0 to 100.0 ºC \/ 23.0 to 212.0 ºF *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\/System Requirements\u003c\/td\u003e\n\u003ctd\u003e  Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownload Information\u003c\/td\u003e\n\u003ctd\u003e Hanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI12922 (HALO) is supplied with auger, storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, fill solution, battery, quality certificate, and instruction sheet. Smartphone and tablet not included.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI12922\"\u003eHALO\u003csup\u003e®\u003c\/sup\u003e Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless Soil pH Electrode - HI12922\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871211094385,"sku":"HI12922","price":27430.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi12922_front_2017.jpg?v=1792645885"},{"product_id":"halo-bluetooth-wireless-ph-electrode-for-test-tubes-hi13302","title":"HALO® Bluetooth® Wireless pH Electrode for Test Tubes - HI13302","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eDownload the FREE app and try before you buy!\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.hannainst.hannalab\u0026amp;hl=en\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Google.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/itunes.apple.com\/us\/app\/hanna-lab\/id913755813?ls=1\u0026amp;mt=8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Apple.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI13302_Angle_2017_720x720_72_RGB.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe HALO® Wireless pH probe incorporates Bluetooth Smart technology® Smart technology with an application-specific design. This electrode features include general purpose (GP) glass,  spheric bulb,  integrated temperature sensor,  and a slim glass body that fits easily into a test tube or a vial.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_GP_glass.png\" alt=\"GP glass\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGeneral Purpose Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eGeneral Purpose (GP) glass,  as the name implies,  is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples from -5 to 50℃ (23 to 122℉).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_bulb.png\" alt=\"spherical bulb\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSpheric Glass Tip\u003c\/h4\u003e\n\u003cp\u003eThe spheric bulb is for general purpose use within laboratory environments and applications that measure aqueous solutions due to its large surface area. Other tip shapes include conic for penetration and flat tip for surface measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_temp_sensor.png\" alt=\"built-in temperature sensor\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-In Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eHI13302 features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode. A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in order to compensate for the effect that temperature has on the membrane potential as predicted by the Nernst equation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI13302_5mm_Tip.png\" alt=\"pH electrode\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_5mm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003e5 mm Glass Body\u003c\/h5\u003e\n\u003cp\u003eThe glass body of the HI13302 is only 5 mm in diameter allowing for the measurement of pH in test tubes and other small vials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1330_open_junction.png\" alt=\"Open Junction\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eDouble Junction with Open Reference\u003c\/h5\u003e\n\u003cp\u003eThe HI13302 is a double junction design. pH electrodes are available as single junction or double junction. A double junction pH electrode uses 3.5M KCl in the outer reference,  which does not react Tris buffer or metal to cause a precipitate that would clog the junction. The HI13302 has an open outer reference junction that also resists clogging and requires very little sample to take a measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eHanna Lab App\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes can connect with HI2202 edge\u003csup\u003eblu\u003c\/sup\u003e meter or a compatible Apple or Android device running the Hanna Lab App.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Android-Compatible.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe Hanna Lab App turns a compatible Apple or Android device into a full-featured pH meter when used with the Hanna HALO pH probe with Bluetooth Smart technology. Functions include calibration,  measurement,  data logging,  graphing and data sharing. Measurement and logging of pH and temperature at one second intervals start as soon as the probe is connected. Measurements can be displayed alone on the display,  with tabulated data,  or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/calibration.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFive-Point Calibration\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App incorporates a probe calibration using up to five pH buffers that are automatically recognized and temperature corrected to 25.0ºC during calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo2.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReal-Time Data\u003c\/h4\u003e\n\u003cp\u003eDisplay of pH and temperature updated every second. Readings are automatically saved to a history file every hour,  limited only by the available memory on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo3.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFluid,  Dynamic Graphing\u003c\/h4\u003e\n\u003cp\u003eMeasurement can be displayed with tabulated data or a graph on the display. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\n\u003cp\u003eConnecting the HALO probe to the Hanna Lab App is simple. Tap the Bluetooth icon in the top-right corner to view all available HALO probes then press the button on your HALO probe. Select the newly discovered HALO probe from the list of available probes. If a previously associated probe is in discovery mode when the app is opened it will connect to that probe automatically.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/appenabledthm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP (Good Laboratory Practice)\u003c\/h4\u003e\n\u003cp\u003eDisplays date and time of current calibration,  probe offset,  and average slope,  along with calibrated buffers,  mV values,  temperature and slopes between each buffer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-alarm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-share.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog \u0026amp; Share Data\u003c\/h4\u003e\n\u003cp\u003eSaved log files may be annotated with measurement specific information. Data is easily shared via email in CSV format.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-help.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp \u0026amp; Tutorials\u003c\/h4\u003e\n\u003cp\u003eDemo probe mode helps you explore features of the Hanna Lab App. General app information,  General HALO information,  pH tutorial,  maintenance tutorial,  and contact information are available in help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHanna Lab App Features\/Benefits:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConnects to HALO electrodes via Bluetooth Smart Technology (Bluetooth 4.0)\u003cbr\u003eUp to five-point pH calibration with seven standard pH buffers available\u003cbr\u003eCalibration reminder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eAlerts you when HALO needs calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eReal-time data\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays pH and temperature updated every second\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBasic GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration along with probe offset and average slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFull GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFluid,  dynamic graphing\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using the pinch-to-zoom technology for enhanced  viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMeasurement alarms\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts you if the measurement threshold is exceeded\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne button sample tagging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePressing either the probe icon in the Hanna Lab App or button on the HALO pH probe will tag sample data for easy reference\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eData-logging with custom annotations\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSaved log files may be annotated with measurement specific information\u003c\/li\u003e\n\u003cli\u003eData is autosaved every hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFour ways to save and share data:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll data since last autosave\u003c\/li\u003e\n\u003cli\u003eAnnotations only\u003c\/li\u003e\n\u003cli\u003eAll data within a timed interval\u003c\/li\u003e\n\u003cli\u003eAnnotations only within a timed interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eShare data via email in CSV format\u003cbr\u003e\u003cbr\u003e Help and tutorials:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDemo probe mode to help explore features of the Hanna Lab App\u003c\/li\u003e\n\u003cli\u003eGeneral app information\u003c\/li\u003e\n\u003cli\u003eGeneral HALO information\u003c\/li\u003e\n\u003cli\u003epH tutorial\u003c\/li\u003e\n\u003cli\u003eMaintenance tutorial\u003c\/li\u003e\n\u003cli\u003eContact information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility:\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes are compatible with HI2202 edgeblu meter and the following devices: \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eAndroid\u003c\/strong\u003e\u003cbr\u003e Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eiOS\u003c\/strong\u003e\u003cbr\u003e iPad (3rd generation or newer)\u003cbr\u003e iPhone (4S or newer)\u003cbr\u003e iPod Touch (5th generation or newer)\u003cbr\u003e \u003cbr\u003e Information about which products have Bluetooth Smart Technology (4.0),  also known as low energy (LE),  can be found \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/List_of_iOS_devices\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/v1yd9ivxgc?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/40e78888f8bf4b55edc940174475d319898347de.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI13302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HALO\u003csup\u003e®\u003c\/sup\u003e Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless pH Electrode for Test Tubes - HI13302\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e open junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd\u003e viscolene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e general purpose (GP)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e spherical\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 12 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e -5 to 50°C (23 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/183 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e built in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e Bluetooth Smart (Bluetooth 4.0), 10 m (33') range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e CR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e test tubes, vials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e -2.000 to 16.000 pH \u003cbr\u003e ±800 mV\u003cbr\u003e -20.0 to 120.0 ºC *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1, 0.01, 0.001 pH \u003cbr\u003e 1, 0.1 mV\u003cbr\u003e0.1 ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e ±0.005 pH \u003cbr\u003e ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e Up to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffers\u003c\/td\u003e\n\u003ctd\u003e 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from -5.0 to 100.0 ºC \/ 23.0 to 212.0 ºF *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\/System Requirements\u003c\/td\u003e\n\u003ctd\u003e  Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownload Information\u003c\/td\u003e\n\u003ctd\u003e Hanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI13302 (HALO) is supplied with storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, battery, quality certificate and instruction sheet.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI13302\"\u003eHALO\u003csup\u003e®\u003c\/sup\u003e Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless pH Electrode for Test Tubes - HI13302\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871219548529,"sku":"HI13302","price":40361.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi13302_front_2017.jpg?v=1792645891"},{"product_id":"halo-bluetooth-wireless-ph-meter-for-flat-surfaces-hi14142","title":"HALO®  Bluetooth® Wireless pH Meter for Flat Surfaces  - HI14142","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eDownload the FREE app and try before you buy!\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.hannainst.hannalab\u0026amp;hl=en\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Google.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/itunes.apple.com\/us\/app\/hanna-lab\/id913755813?ls=1\u0026amp;mt=8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Apple.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Skin_Halo_Tip.png\" alt=\"HALOTM - Flat tip pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe HALO® Wireless pH Meter for Flat Surfaces incorporates Bluetooth® Smart technology with an application-specific design. There are several features that make it ideal for measuring the pH of agar plates,  skin,  or leather,  by providing a flat glass tip that allows a larger surface area than a typical pH electrode..\u003c\/p\u003e\n\u003ch5\u003eFlat Tip Bulb\u003c\/h5\u003e\n\u003cp\u003eThe flat shaped tip design allows for easy measurement on surfaces (such as agar plates,  skin,  leather,  paper,  and samples that cannot easily be penetrated) or samples with a small volume.\u003c\/p\u003e\n\u003ch5\u003eLow Temperature Glass Formulation\u003c\/h5\u003e\n\u003cp\u003eLow Temperature (LT) glass Low temperature glass for fast stabilization and more accurate results at lower temperatures. This is beneficial since many food products are stored at low temperatures.\u003c\/p\u003e\n\u003ch5\u003eOpen Junction Design\u003c\/h5\u003e\n\u003cp\u003eThe open junction design consists of a solid gel (viscolene) interface between the sample and internal reference. This interface not only prevents silver from entering the sample,  but also makes it impermeable to clogging from food products,  maintaining a fast response and stable reading.\u003c\/p\u003e\n\u003ch5\u003eMaintenance Free Gel-filled Reference\u003c\/h5\u003e\n\u003cp\u003eBecause the internal reference is gel,  there is no fill solution to replenish as the probe is used. Other than routine calibration and cleaning,  this a maintenance free probe.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Temperature Sensor\u003c\/h5\u003e\n\u003cp\u003eThe thermistor temperature sensor built into the tip of the pH electrode. A thermistor based temperature sensor provides for a high accuracy temperature while being in the tip of the electrode allows for a rapid temperature compensated measurement.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-hanna-lab-ipad-iphone.jpg\" alt=\"HALOTM - pH Probe with Bluetooth Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo2.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReal-Time Data\u003c\/h4\u003e\n\u003cp\u003eDisplay of beer pH and temperature updated every second. Readings are automatically saved to a history file every hour,  limited only by the available memory on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo3.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFluid,  Dynamic Graphing\u003c\/h4\u003e\n\u003cp\u003eMeasurements can be displayed alone on the display,  with tabulated data,  or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/appenabledthm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP (Good Laboratory Practice)\u003c\/h4\u003e\n\u003cp\u003eDisplays date and time of current calibration,  offset,  and average slope,  along with calibrated buffers,  mV values,  temperature and slopes between each buffer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11312hand.jpg\" alt=\"HALO pH probe features\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-alarm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-share.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog \u0026amp; Share Data\u003c\/h4\u003e\n\u003cp\u003eSaved log files may be annotated with measurement-specific information. Data is easily shared via email in CSV format.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-help.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp \u0026amp; Tutorials\u003c\/h4\u003e\n\u003cp\u003eDemo mode helps you explore features of the Hanna Lab App. General app information,  HALO information,  pH tutorial,  maintenance tutorial,  and contact information are available in help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHALO Features\/Benefits:\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eConnects to Hanna Lab App with a compatible Apple or Android Device via Bluetooth Smart Technology (Bluetooth 4.0)\u003cbr\u003eUp to five-point pH calibration with seven standard pH buffers available\u003cbr\u003eCalibration reminder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts you when HALO pH meter for beer needs calibration\u003c\/li\u003e\n\u003cli\u003eAppropriate preprogrammed calibration buffer set for application specific Halo pH electrodes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eReal-time data\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays pH and temperature updated every second\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBasic Good Laboratory Practice (GLP)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration along with offset and average slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFull GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration,  offset and average slope along with calibrated buffers,  mV values,  temperature and slopes between each buffer\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFluid,  dynamic graphing\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMeasurement alarms\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts you if the measurement threshold is exceeded\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne button sample tagging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePressing either the icon in the Hanna Lab App or button on the HALO will tag sample data for easy reference\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eData logging with custom annotations\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSaved log files may be annotated with measurement specific information\u003c\/li\u003e\n\u003cli\u003eData is autosaved every hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFour ways to save and share data:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll data since last autosave\u003c\/li\u003e\n\u003cli\u003eAnnotations only\u003c\/li\u003e\n\u003cli\u003eAll data within a timed interval\u003c\/li\u003e\n\u003cli\u003eAnnotations only within a timed interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eShare data via email in CSV format\u003cbr\u003e\u003cbr\u003eHelp and tutorials:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDemo mode to help explore features of the Hanna Lab App\u003c\/li\u003e\n\u003cli\u003eGeneral app information\u003c\/li\u003e\n\u003cli\u003eGeneral HALO information\u003c\/li\u003e\n\u003cli\u003epH tutorial\u003c\/li\u003e\n\u003cli\u003eMaintenance tutorial\u003c\/li\u003e\n\u003cli\u003eContact information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility:\u003c\/h2\u003e\n\u003ch5\u003eHALO is compatible with the following devices:\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eAndroid\u003c\/strong\u003e\u003cbr\u003eCompatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e\u003cbr\u003e \u003cstrong\u003eiOS\u003c\/strong\u003e\u003cbr\u003eiPad (3rd generation or newer)\u003cbr\u003eiPhone (4S or newer)\u003cbr\u003eiPod Touch (5th generation or newer)\u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eHI2202 edge\u003csup\u003eblu\u003c\/sup\u003e Meter\u003c\/strong\u003e\u003cbr\u003e\u003cbr\u003eInformation about which products have Bluetooth Smart Technology (4.0),  also known as low energy (LE),  can be found \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/List_of_iOS_devices\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI14142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HALO\u003csup\u003e®\u003c\/sup\u003e  Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless pH Meter for Flat Surfaces  - HI14142\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 12.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e Viscolene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e Low Temperature (LT) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e flat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 12 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 50 mm \/ 114 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm (glass)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e Bluetooth Smart (Bluetooth 4.0), 10 m (33') range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e CR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e flat surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e  -2.000 to 16.000 pH \u003cbr\u003e ±800 mV \u003cbr\u003e-20.0 to 120.0 ºC *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1, 0.01, 0.001 pH \u003cbr\u003e 1, 0.1 mV\u003cbr\u003e0.1 ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e ±0.005 pH \u003cbr\u003e ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e up to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffers\u003c\/td\u003e\n\u003ctd\u003e 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from -5.0 to 100.0 ºC \/ 23.0 to 212.0 ºF *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\/System Requirements\u003c\/td\u003e\n\u003ctd\u003e  Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownload Information\u003c\/td\u003e\n\u003ctd\u003e Hanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI14142 (HALO) is supplied with storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, battery, quality certificate and instruction sheet. Smartphone and tablet not included.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI14142\"\u003eHALO\u003csup\u003e®\u003c\/sup\u003e Bluetooth\u003csup\u003e®\u003c\/sup\u003e Wireless pH Meter for Flat Surfaces - HI14142\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871229411697,"sku":"HI14142","price":30673.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-calibration-reminder-and-ph-measurement-alarms-ipad-screen-hanna-lab-app_9.jpg?v=1792645899"},{"product_id":"t-shaped-celsius-thermometer-125mm-hi145-00","title":"T-Shaped Celsius Thermometer (125mm) - HI145-00","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion, such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on, a calibration test is immediately performed. With this unique feature, the HI145 series performs a self-check of its calibration status and displays it on the LCD, ensuring accuracy, repeatability, and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations, making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 125 mm (5\") long AISI 316 stainless steel probe. The sharp conical tip provides fast response and improved accuracy over the entire range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI145-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eT-Shaped Celsius Thermometer (125mm) - HI145-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-50.0 to 220°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (-50.0 to 199.9°C); 1°C (200 to 220°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3°C (-20 to 90°C); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e92 x 165 x 38 mm (3.6 x 6.5 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e65 g (2.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-00 is supplied complete with 125 mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI145-00\" target=\"_blank\" rel=\"noopener\"\u003eT-Shaped Celsius Thermometer (125mm) - HI145-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871229542769,"sku":"HI145-00","price":6195.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145_1.jpg?v=1792645902"},{"product_id":"t-shaped-fahrenheit-thermometer-125mm-hi145-01","title":"T-Shaped Fahrenheit Thermometer (125mm) - HI145-01","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion,  such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on,  a calibration test is immediately performed. With this unique feature,  the HI145 series performs a self-check of its calibration status and displays it on the LCD,  ensuring accuracy,  repeatability,  and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations,  making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 125 mm (5\") long AISI 316 stainless steel probe. The sharp conical tip provides fast response and improved accuracy over the entire range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI145-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e T-Shaped Fahrenheit Thermometer (125mm) - HI145-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -58.0 to 428°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°F (-58.0 to 199.9°F); 1°F (200 to 428°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.6°F (-4 to 194°F); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 92 x 165 x 38 mm (3.6 x 6.5 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 65 g (2.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-01 is supplied complete with 125 mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI145-01\"\u003eT-Shaped Fahrenheit Thermometer (125mm) - HI145-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871229575537,"sku":"HI145-01","price":6195.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-01_hi145-30_face_1.jpg?v=1792645903"},{"product_id":"t-shaped-celsius-thermometer-300mm-hi145-20","title":"T-Shaped Celsius Thermometer (300mm) - HI145-20","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion, such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on, a calibration test is immediately performed. With this unique feature, the HI145 series performs a self-check of its calibration status and displays it on the LCD, ensuring accuracy, repeatability, and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations, making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 300 mm (12\") long AISI 316 stainless steel probe, ideal for monitoring hot liquids, such as in deep frying and soup preparation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI145-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eT-Shaped Celsius Thermometer (300mm) - HI145-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-50.0 to 220°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (-50.0 to 199.9°C); 1°C (200 to 220°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3°C (-20 to 90°C); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e92 x 340 x 38 mm (3.6 x 13.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e80 g (2.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-20 is supplied complete with 300mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI145-20\" target=\"_blank\" rel=\"noopener\"\u003eT-Shaped Celsius Thermometer (300mm) - HI145-20\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871230984561,"sku":"HI145-20","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-20_2.jpg?v=1792645903"},{"product_id":"t-shaped-fahrenheit-thermometer-300mm-hi145-30","title":"T-Shaped Fahrenheit Thermometer (300mm) - HI145-30","description":"\u003cp\u003eHI145 thermometers were developed for HACCP programs that require high standards of performance with simplicity of use. The durable T-shaped handle fits comfortably in hand and is ideal for applications where applied force is necessary for insertion,  such as with incoming meat inspection and semi-frozen foods. The LCD positioned on top of the meter allows for easy reading in cooking applications.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - When the HI145 is turned on,  a calibration test is immediately performed. With this unique feature,  the HI145 series performs a self-check of its calibration status and displays it on the LCD,  ensuring accuracy,  repeatability,  and condence in readings.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHACCP Compliant\u003c\/strong\u003e - The HI145 is in compliance with food regulations,  making it an ideal instrument for use as a tool for control in HACCP analysis.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAISI 316 Stainless Steel Probe\u003c\/strong\u003e - The HI145 thermometer is equipped with a 300 mm (12\") long AISI 316 stainless steel probe,  ideal for monitoring hot liquids,  such as in deep frying and soup preparation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eEnhanced Battery Life\u003c\/strong\u003e- The HI145 uses AAA batteries and offers an exceptional 10, 000 hours of continuous use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto Shut-off\u003c\/strong\u003e- The battery life of the thermometer is preserved by this feature which automatically turns the meter off after 8 minutes of non-use.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI145-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e T-Shaped Fahrenheit Thermometer (300mm) - HI145-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -58.0 to 428°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°F (-58.0 to 199.9°F); 1°F (200 to 428°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.6°F (-4 to 194°F); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AAA \/ approximately 10,000 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 92 x 340 x 38 mm (3.6 x 13.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 80 g (2.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI145-30 is supplied complete with 300mm probe, battery, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI145-30\"\u003eT-Shaped Fahrenheit Thermometer (300mm) - HI145-30\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871233573233,"sku":"HI145-30","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi145-30.jpg?v=1792645910"},{"product_id":"professional-waterproof-portable-ph-orp-meter-hi98190","title":"Professional Waterproof Portable pH\/ORP Meter - HI98190","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eFor the measurement of pH, the HI98190 handheld pH meter comes with an HI12963 titanium body amplified pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium probe body is chemically resistant to aggressive chemicals and is virtually unbreakable. The HI12963 pH\/temperature electrode features a newly designed Quick Connect DIN connector that provides a simple waterproof connection without any threads.\u003cbr\u003e\u003cbr\u003eHanna's unique CAL Check™ feature alerts the user to potential problems during the calibration process. By comparing previous calibration data to the current calibration, the meter will alert the user with display prompts when the probe needs to be cleaned or is broken, and if the pH buffer might be contaminated. After calibration, the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. Calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.\u003cbr\u003e\u003cbr\u003ePressing the \"AutoHoldin. virtual key seen in measurement mode, the portable ph meter will freeze a stable reading, allowing for the reading to be documented or logged. An \"out of calibration rangein. warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.\u003cbr\u003e\u003cbr\u003eThe log-on-demand mode allows the user to record and save up to 200 samples (100 for pH and 100 for mV). This data, along with the associated GLP data, can then be transferred to a PC with Hanna's HI920015 micro USB cable and HI92000 software.\u003cbr\u003e\u003cbr\u003eThe high contrast graphic LCD is easy to read outdoors in bright sunlight as well as in low-lit areas with the use of the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.\u003cbr\u003e\u003cbr\u003eThe compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter and electrode, beakers, buffer solutions, cleaning solutions, and storage solutions.\u003c\/p\u003e\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSetup screen\u003c\/h4\u003e\n\u003cp\u003eOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-CAL.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration\u003c\/h4\u003e\n\u003cp\u003epH calibration features detailed CAL Check™ messages. Users are guided through the calibration procedure with step-by-step on-screen instructions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP\u003c\/h4\u003e\n\u003cp\u003eComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003epH CAL Check™\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/li\u003e\n\u003cli\u003eDisplays overall probe condition based on offset and slope after calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003ch5\u003eFive-point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold - freezes reading on display upon stabilization\u003c\/h5\u003e\n\u003ch5\u003eGLP features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data including date, time, pH calibration buffers, offset and slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200 hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Food \u0026amp; Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental\u003c\/p\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003cdiv style=\"position: relative; max-width: 100%; margin: 0 0 32px;\"\u003e\u003cvideo style=\"width: 100%; aspect-ratio: 16 \/ 9; height: auto; border: 0;\" src=\"https:\/\/cdn.shopify.com\/videos\/c\/o\/v\/92c2819bf7a34a3cbb71080a6ee9cf37.mp4\" controls=\"controls\" playsinline=\"\"\u003e\n\u003c\/video\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003esku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98190\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH \/ -2.00 to 20.00 pH \/ -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Accuracy @ 25°C \/ 77°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH \/ ±0.01 pH \/ ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to five point calibration, seven standard buffers available (pH 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45), and five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C (-4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Accuracy @ 25°C \/ 77°F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.4 °C (±0.8 °F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eLog Feature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOn demand, 200 samples (100 pH and 100 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eConnectivity\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePC Connectivity - opto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eGLP\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4 pcs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Consumption\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eapprox. 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 to 50 °C (32 to 122 °F) max. RH 100% IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e192 x 93 x 35.2 mm (7.3 x 3.6 x 1.4in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e407 g (14.2 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eOrdering Information\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI98190 is supplied with HI12963 titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720190 hard carrying case.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eWarranty\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 years\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eRecommended Probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI12963 Titanium body, pH electrode with internal temperature sensor, quick DIN connector and 1 m (3.3' cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cp\u003eHI98190 is supplied with HI12963 titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720190 hard carrying case.\u003c\/p\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn2.hubspot.net\/hubfs\/2134380\/product-manuals\/MAN98191_05_19.pdf\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eProfessional Waterproof Portable pH\/ORP Meter - HI98190\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871241503089,"sku":"HI98190","price":82815.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98190_1.jpg?v=1792645919"},{"product_id":"ph-orp-temperature-combo-tester-hi98121","title":"pH\/ORP\/Temperature Combo Tester - HI98121","description":"\u003cp\u003eThe HI98121 is a lightweight ergonomically designed tester. This tester is designed to float making it ideal for taking readings virtually anywhere. With the HI98121 it is possible to monitor both pH and ORP at the same time. The HI98121 is commonly used to monitor pH and chlorine for many applications including swimming, food sanitization, plating wastewater treatment, and cooling tower water treatment.\u003c\/p\u003e\n\u003cp\u003eBy definition pH is the measurement of the voltage generated by an electrochemical cell at zero current. The potential generated is proportional to the thermodynamic activity of the ion being measured.\u003c\/p\u003e\n\u003cp\u003eSimilar to a pH measurement that quantifies the how acidic or alkaline solutions are, ORP (Oxidation Reduction Potential) measurements quantify the overall state of a solution as having the ability to oxidize or reduce a chemical species. Oxidizing and reducing reagents are used to participate in chemical reactions known as a redox reaction.\u003c\/p\u003e\n\u003cp\u003eAn ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange, a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eWaterproof\u003c\/li\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eHOLD feature\u003c\/li\u003e\n\u003cli\u003eSimple to use\u003c\/li\u003e\n\u003cli\u003eEconomical\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003epH\/ORP\/Temperature Combo Tester - HI98121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic for pH readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 replaceable pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003efixed ORP sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approximately 250 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98121 (ORP\/pH) is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98121\" target=\"_blank\" rel=\"noopener\"\u003epH\/ORP\/Temperature Combo Tester - HI98121\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871251431793,"sku":"HI98121","price":23427.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98121.jpg?v=1792645946"},{"product_id":"silica-high-range-checker-hc-hi770","title":"Silica High-Range Checker® HC - HI770","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI770 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure silica. Silica is found in all natural surface and saline waters in the dissolved form. Due to the potential to cause scaling, it is undesirable and therefore monitored in industrial applications, and heating and reverse osmosis systems. Designed as a more accurate alternative to chemical test kits, the HI770 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Industrial, Aquariums\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSilica High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI770\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA method 370.1 for drinking, surface and saline waters and Standard Method 4500-SiO₂ C for domestic and industrial waters.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI770 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, silica HR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI770\" target=\"_blank\" rel=\"noopener\"\u003eSilica High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI770\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871255986545,"sku":"HI770","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi770-checkerhc-front.jpg?v=1792645964"},{"product_id":"silica-low-range-checker-hc-hi705","title":"Silica Low-Range Checker® HC - HI705","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI705 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure silica. Silica is found in all natural waters in the dissolved form. Due to the potential to cause scaling, it is undesirable and therefore monitored in industrial applications, and in heating and reverse osmosis systems. Designed as a more accurate alternative to chemical test kits, the HI705 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e* To zero 6 drops of reagent A and one packet of reagent B are added to the sample to be tested.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSilica Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI705\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the ASTM D859, heteropoly blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI705 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) cuvettes with caps, silica LR reagent starter kit for 12 tests (1 bottle of reagent A, 12 packets of reagent B, and 12 packets of reagent C), battery, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI705\" target=\"_blank\" rel=\"noopener\"\u003eSilica Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI705\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871256019313,"sku":"HI705","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi705-checkerhc-front_1.jpg?v=1792645965"},{"product_id":"environmental-monitoring-chemical-test-kit-hi3814","title":"Environmental Monitoring Chemical Test Kit - HI3814","description":"\u003cp\u003eThe HI3814 is a chemical test kit that determines that uses titration and direct measurement to measure six parameters common in environmental testing: acidity, alkalinity, carbon dioxide, hardness, dissolved oxygen, and pH. The HI3814 is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the pH tester,  sample beaker,  indicator and reagent bottles and packets,  and glass bottle for dissolved oxygen.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eThe six most important parameters in environmental applications can be monitored with this combination chemical test kit. They include: acidity,  alkalinity,  carbon dioxide,  dissolved oxygen,  hardness,  and pH. This kit is ideal not only for professionals,  but also for students studying environmental science,  as it offers great performance and ease of use. HI3814 is equipped with all the accessories and reagents to perform over 100 tests for each parameter. The pHep®,  our popular pH electronic tester,  is included for your convenience. This small and easy to use pH meter will provide more accurate and reliable pH readings than conventional litmus paper. The pHep® also has the added benefit of introducing students to the use of a pH meter.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Environmental Monitoring Chemical Test Kit - HI3814\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003e electronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003e life of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003e modified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L CaCO₃; 0 to 500 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 5 mg\/L (0 to 500 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Method\u003c\/td\u003e\n\u003ctd\u003e methyl orange \/ phenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003e phenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 10.0 mg\/L CO₂; 0.0 to 50.0 mg\/L CO₂; 0 to 100 mg\/L CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mg\/L (0.0 to 10.0 mg\/L range); 0.5 mg\/L (0.0 to 50.0 mg\/L range); 1 mg\/L (0 to 100 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Method\u003c\/td\u003e\n\u003ctd\u003e phenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003e EDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 2.3 kg (5.1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3814 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, electronic pH tester, hard carrying case, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3814\"\u003eEnvironmental Monitoring Chemical Test Kit - HI3814\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871257035121,"sku":"HI3814","price":29036.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3814_2.jpg?v=1792645977"},{"product_id":"water-quality-test-kit-hi3817","title":"Water Quality Test Kit - HI3817","description":"\u003cp\u003eThe HI3817 is a chemical test kit that determines that uses titration,  colorimetry,  and direct measurement to measure six parameters common to water quality testing: alkalinity,  chloride,  hardness,  iron,  pH,  and sulfite. The HI3817 is supplied with all of the necessary reagents and equipment to perform each analysis,  and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the pH tester,  sample beaker,  indicator and reagent bottles and packets,  and color comparison cube.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eSix of the most common parameters in water quality can be monitored with this combination chemical test kit. They include: alkalinity,  chloride,  hardness,  iron,  pH,  and sulfite. These parameters are important in determining the corrosive characteristics of water due to carbonates and chloride. Sulfite is also critical to prevent pitting and oxidation of metal components. A high level of sulfite results in a lowered pH,  which can also promote corrosion in drinking water infrastructure. This kit is ideal not only for professionals,  but also for students studying environmental science,  as it offers great performance and ease of use. HI3817 is equipped with all the accessories and reagents to perform multiple tests for each parameter. The pHep®,  our popular pH electronic tester,  is included for your convenience. This small and easy to use pH meter will provide more accurate and reliable pH readings than conventional litmus paper. The pHep® also has the added benefit of introducing students to the use of a pH meter.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI3817 Water Quality Test Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003e electronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003e life of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003e phenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L Cl⁻; 0 to 1000 mg\/L Cl⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 10 mg\/L (0 to 1000 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003e mercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003e EDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Measurement Type\u003c\/td\u003e\n\u003ctd\u003e colorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003e phenanthroline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 20.0 mg\/L Na₂SO₃; 0 to 200 mg\/L Na₂SO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.2 mg\/L (0.0 to 20.0 mg\/L range); 2 mg\/L (0 to 200 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Method\u003c\/td\u003e\n\u003ctd\u003e iodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3817 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of iron, which include reagents for 50 tests, electronic pH tester, hard carrying case and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3817\"\u003eHI3817 Water Quality Test Kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871257231729,"sku":"HI3817","price":35690.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3817_2.jpg?v=1792645979"},{"product_id":"cooling-and-boiler-chemical-test-kit-hi3821","title":"Cooling and Boiler Chemical Test Kit - HI3821","description":"\u003cp\u003eThe HI3821 is a chemical test kit that determines that uses titration and colorimetry to measure six parameters common to cooling and boiler systems: alkalinity, chloride, hardness, dissolved oxygen, phosphate, and sulfite. The HI3821 is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the dissolved oxygen glass bottle,  sample beaker,  indicator and reagent bottles and packets,  and color comparison cube.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eCorrosion can occur in many key areas of a boiler. It can shorten the life of a boiler,  or at the very least,  increase the costs associated with maintaining a boiler. Corrosion can form in water heaters,  deaerators,  superheater tubes,  and economizers,  among other places. Monitoring the alkalinity,  chloride,  hardness,  dissolved oxygen,  phosphate,  and sulfite concentrations in cooling and boiler systems is essential in preventing hazardous or costly situations.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Cooling and Boiler Chemical Test Kit - HI3821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003e modified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003e phenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L Cl⁻; 0 to 1000 mg\/L Cl⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 10 mg\/L (0 to 1000 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003e mercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003e EDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Measurement Type\u003c\/td\u003e\n\u003ctd\u003e colorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 5 mg\/L PO₄³⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003e ascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Number of Test\u003c\/td\u003e\n\u003ctd\u003e 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 20.0 mg\/L Na₂SO₃; 0 to 200 mg\/L Na₂SO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.2 mg\/L (0.0 to 20.0 mg\/L range); 2 mg\/L (0 to 200 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Method\u003c\/td\u003e\n\u003ctd\u003e iodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 2.5 kg (5.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3821 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of phosphate, which includes reagents for 50 tests, hard carrying case, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3821\"\u003eCooling and Boiler Chemical Test Kit - HI3821\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871261917553,"sku":"HI3821","price":48183.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3821_1.jpg?v=1792645983"},{"product_id":"sulfite-chemical-test-kit-hi3822","title":"Sulfite Chemical Test Kit - HI3822","description":"\u003cp\u003eThe HI3822 is a chemical test kit that determines the sulfite concentration in two ranges: 0 to 20 mg\/L and 0 to 200 mg\/L Na\u003csub\u003e2\u003c\/sub\u003eSO\u003csub\u003e3\u003c\/sub\u003e. The HI3822 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 110 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the sample beakers,  indicator and reagent bottles,  and calibrated syringe.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eReadings from 0 to 20 mg\/L are determined to 0.2 mg\/L resolution.\u003c\/li\u003e\n\u003cli\u003eReadings from 0 to 200 mg\/L are determined to 2 mg\/L resolution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3822-100 can be ordered to replace the reagents supplied with the kit.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eThere are many reasons to monitor the concentration of sulfite in water. In boiler feed and effluent waters,  a sulfite concentration of approximately 20 mg\/L must be maintained to prevent pitting and oxidation of metal components. A high level of sulfite results in a lowered pH,  thus promoting corrosion. The monitoring of sulfite is important in environmental control as well. Sulfite ions are toxic to aquatic lifeforms; the chemical demand that sulfide produces on oxygen in water can destroy the delicate ecological balance of lakes,  rivers and ponds.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3822\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sulfite Chemical Test Kit - HI3822\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 20 mg\/L Na₂SO₃; 0 to 200 mg\/L Na₂SO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.2 mg\/L (0 to 20 mg\/L range); 2 mg\/L (0 to 200 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Method\u003c\/td\u003e\n\u003ctd\u003e iodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 910 g (34.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 260x120x60 mm (10.2x4.7x2.4 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3822 test kit comes with 30 mL sulfamic acid solution, 30 mL EDTA reagent, 15 mL sulfuric acid solution, 10 mL starch indicator, 120 mL titrant solution, 20 mL calibrated vessel, 50 mL calibrated vessel, and calibrated syringe with tip.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3822\"\u003eSulfite Chemical Test Kit - HI3822\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871261950321,"sku":"HI3822","price":11078.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3822_2.jpg?v=1792645984"},{"product_id":"marine-test-kit-hi3823","title":"Marine Test Kit - HI3823","description":"\u003cp\u003eThe HI3823 is a chemical test kit that uses titration and direct measurement to measure six parameters common in aquaculture testing: alkalinity, carbon dioxide, hardness, dissolved oxygen, pH, and salinity. The HI3823 is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the pH tester, sample beaker, indicator and reagent bottles and packets, and glass bottle for dissolved oxygen.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eThe six most important parameters in aquaculture applications can be monitored with this combination chemical test kit. They include: alkalinity, carbon dioxide, dissolved oxygen, hardness, pH, and salinity. This kit is ideal not only for professionals, but also for educators and students studying marine science, as it offers great performance and ease of use. HI3823 is equipped with all the accessories and reagents to perform over 100 tests for each parameter. The pHep®, our popular pH electronic tester, is included for your convenience. This small and easy to use pH meter will provide more accurate and reliable pH readings than conventional litmus paper. The pHep® also has the added benefit of introducing students to the use of a pH meter.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Test Kit - HI3823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003eelectronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003elife of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003emodified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L CO₂; 0.0 to 50.0 mg\/L CO₂; 0 to 100 mg\/L CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (0.0 to 10.0 mg\/L range); 0.5 mg\/L (0.0 to 50.0 mg\/L range); 1 mg\/L (0 to 100 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.4 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Method\u003c\/td\u003e\n\u003ctd\u003emercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 kg (5.1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3823 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, electronic pH tester, hard carrying case, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3823\" target=\"_blank\" rel=\"noopener\"\u003eMarine Test Kit - HI3823\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871262048625,"sku":"HI3823","price":53805.6,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3823.jpg?v=1792645985"},{"product_id":"combo-ph-conductivity-tds-tester-low-range-hi98129","title":"Combo pH\/Conductivity\/TDS Tester (Low Range) - HI98129","description":"\u003cp\u003eThe HI98129 is a highly accurate, waterproof pH meter that can also measure EC\/TDS in the low range (0 to 3999 µS\/cm EC\/ 0 to 2000 ppm TDS) and temperature. This floating, waterproof combination tester has an easy to read, LCD and an automatic shut-off. In addition, pH and EC\/TDS readings are automatically temperature compensated (ATC) to prevent temperature-related variations in your measurements. For EC\/TDS readings, the EC\/TDS conversion factor (CONV) is selectable by the user, as well as the temperature compensation coefficient β (BETA).\u003c\/p\u003e\n\u003ch4\u003eReplaceable pH Electrode Cartridge\u003c\/h4\u003e\n\u003cp\u003eThe HI98129 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!\u003c\/p\u003e\n\u003ch4\u003eHigh Accuracy EC\/TDS Graphite Probe\u003c\/h4\u003e\n\u003cp\u003eThe graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e3 sensors in a single meter\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH electrode with extractable junction\u003c\/p\u003e\n\u003cp\u003eAmperometric EC\/TDS sensor\u003c\/p\u003e\n\u003cp\u003eExposed temperature probe for faster EC\/TDS readings\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWaterproof\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDesigned to float if accidently dropped in sample\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWide pH Range\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH range is from 0.00 to 14.00 pH\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSelectable EC to TDS conversion factor\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eChoice of either a 0.45 or 1.0 conversion factor\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAutomatic Temperature Compensation\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAll readings are compensated for variations in temperature\u003c\/p\u003e\n\u003cp\u003eTemperature displayed in ℃ or ℉ along with pH, EC or TDS reading\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eStability indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHOLD button\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eFreezes reading on the display to allow recording of measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBEPS (Battery Error Prevention System\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBattery % level at startup\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAuto-off feature automatically shuts off meter after 8 minutes of non-use to maximize battery life\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCombo pH\/Conductivity\/TDS Tester (Low Range) - HI98129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 1382 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic with β adjustable from 0.0 to 2.4% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 (replaceable; included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 100 hours of continuous use, auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98129 is supplied with HI73127 pH electrode and HI73128 electrode removal tool, batteries (4 x 1.5V) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98129\" target=\"_blank\" rel=\"noopener\"\u003eCombo pH\/Conductivity\/TDS Tester (Low Range) - HI98129\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871262245233,"sku":"HI98129","price":19524.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98129-ppm_1.jpg?v=1792645989"},{"product_id":"boiler-and-feedwater-chemical-test-kit-hi3827","title":"Boiler and Feedwater Chemical Test Kit - HI3827","description":"\u003cp\u003eThe HI3827 is a chemical test kit that determines that uses titration, colorimetry, and direct measurement to measure six parameters common to boilers and feedwater testing: alkalinity, chloride, hardness, phosphate, pH, and sulfite. The HI3827 is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the pH tester, sample beaker, indicator and reagent bottles and packets, and color comparison cube.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eMonitoring the alkalinity, chloride, hardness, phosphate, pH, and sulfite concentrations in boiler and feedwater is essential in preventing hazardous or costly situations. These parameters are important in determining the corrosive characteristics of water due to carbonates and chloride. Sulfite is also critical to prevent pitting and oxidation of metal components. A high level of sulfite results in a lowered pH, which can also promote corrosion.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3827\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eBoiler and Feedwater Chemical Test Kit - HI3827\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003eelectronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003elife of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L Cl⁻; 0 to 1000 mg\/L Cl⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 10 mg\/L (0 to 1000 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003emercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mg\/L PO₄³⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Number of Test\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L Na₂SO₃; 0 to 200 mg\/L Na₂SO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Resolution\u003c\/td\u003e\n\u003ctd\u003e0.2 mg\/L (0.0 to 20.0 mg\/L range); 2 mg\/L (0 to 200 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Method\u003c\/td\u003e\n\u003ctd\u003eiodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg (4.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3827 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of phosphate, which includes reagents for 50 tests, hard carrying case, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3827\" target=\"_blank\" rel=\"noopener\"\u003eBoiler and Feedwater Chemical Test Kit - HI3827\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871267357041,"sku":"HI3827","price":36287.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3827_2.jpg?v=1792645992"},{"product_id":"formaldehyde-chemical-test-kit-hi3838","title":"Formaldehyde Chemical Test Kit - HI3838","description":"\u003cp\u003eThe HI3838 is a titration-based chemical test kit that determines the formaldehyde concentration in two ranges: 0.0 to 1.0% and 0 to 10%. Each 0.1% with each 0.1 ml of titrant equals 0.1% for the low range and 1% for the high range. The HI3838 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents to perform approximately 110 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the sample beaker, indicator and reagent bottles, and calibrated syringe.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution \u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eReadings from 0.0 to 1.0% are determined to 0.1% resolution.\u003c\/li\u003e\n\u003cli\u003eReadings from 1 to 10% are determined to 1% resolution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3838-100 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 1 (15mL) dropper bottle of Alizarin yellow R indicator, 1 (30 g) bottle sodium sulfite, and 1 (120 mL) bottle of HI3838-0 titrant solution.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eFormaldehyde is an important organic compound used to make many materials and chemical compounds. Its role in many industries varies from holding dyes onto fabrics, to assisting in the electroplating of metals. Formaldehyde is also used in biological preservation, drug testing, and photograph development. Each application uses different levels of formaldehyde and requires monitoring to optimize its given purpose. Formaldehyde is also a large consideration for human health. Due to its widespread use, there are regulations in place for formaldehyde limits within workplaces to avoid overexposure.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFormaldehyde Chemical Test Kit - HI3838\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormaldehyde Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormaldehyde Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 1.0%; 0 to 10%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormaldehyde Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% (0.0 to 1.0% range); 1% (0 to 10% range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormaldehyde Method\u003c\/td\u003e\n\u003ctd\u003esodium sulfite \/ hydrochloric acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFormaldehyde Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e910 g (2 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e260 x 120 x 60 mm (10.2 x 4.7 x 2.4 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3838 test kit comes with 15 mL dropper bottle Alizarin Yellow R indicator, 30 g sodium sulfite, 120 mL HI3838-0 titrant solution, plastic spoon, plastic bottle, 10 mL calibrated vessel, filter cartridge, calibrated titration syringe, and plungers.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3838\" target=\"_blank\" rel=\"noopener\"\u003eFormaldehyde Chemical Test Kit - HI3838\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871269618033,"sku":"HI3838","price":9631.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3838_2.jpg?v=1792646001"},{"product_id":"multiparameter-benchtop-photometer-and-ph-meter-hi83300","title":"Multiparameter Benchtop Photometer and pH meter - HI83300-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eFrom aluminum to zinc, the HI83300 benchtop photometer measures 37 different key water quality parameters using 60 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\n\u003cp\u003eThe HI83300 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eBacklit 128 x 64 Pixel Graphic LCD Display\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit graphic display allows for easy viewing in low light conditions\u003c\/li\u003e\n\u003cli\u003eThe 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement is taken after the countdown timer expires.\u003c\/li\u003e\n\u003cli\u003eCountdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAbsorbance mode\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHanna's exclusive CAL Check cuvettes for validation of light source and detector\u003c\/li\u003e\n\u003cli\u003eAllows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUnits of Measure\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAppropriate unit of measure along with chemical form is displayed along with reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eResult Conversion\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAutomatically convert readings to other chemical forms with the touch of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCuvette Cover\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAids in preventing stray light from affecting measurements\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eDigital pH Electrode Input\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH and temperature with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eSpace saving having a pH meter and photometer built into one meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button\u003c\/li\u003e\n\u003cli\u003eSample ID and User ID information can be added to a logged reading using alphanumeric keypad\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port\u003c\/li\u003e\n\u003cli\u003eData is exported as a .CSV file for use with common spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBattery Status Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eIndicates the amount of battery life left\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eError Messages\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePhotometric error messages include no cap, high zero, and standard too low\u003c\/li\u003e\n\u003cli\u003epH calibration messages include clean electrode, check buffer and check probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/method-selection.png\" alt=\"method selection\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMethod Selection\u003c\/h4\u003e\n\u003cp\u003eUsers can easily select any one of the 60 measurement methods via the dedicated METHOD button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/data-logging.png\" alt=\"data logging\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eData Logging\u003c\/h4\u003e\n\u003cp\u003eUp to 1000 measurement readings can be logged with user and sample ID and recalled for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-measurement-mode.png\" alt=\"ph measurement mode\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003epH Measurement Mode\u003c\/h4\u003e\n\u003cp\u003eSelecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdvanced Optical System\u003c\/h4\u003e\n\u003cp\u003eHI83300 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/OpticalSystem.jpg\" alt=\"photometer multiparameter optical\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHigh Efficiency LED Light Source\u003c\/h4\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch4\u003eHigh Quality Narrow Band Interference Filters\u003c\/h4\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (±1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch4\u003eReference Detector for a Stable Light Source\u003c\/h4\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch4\u003eLarge Cuvette Size\u003c\/h4\u003e\n\u003cp\u003eThe sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch4\u003eFocusing Lens for Greater Light Yield\u003c\/h4\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI83300-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMultiparameter Benchtop Photometer and pH meter - HI83300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH\npH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH\npH electrode: 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH\npH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 ℃; 23.0 to 212.0 °F); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 4.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.003Abs @ 1.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\nSeawater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.00 mg\/L (as Al\u003csup\u003e3+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the aluminon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 3.00 mg\/L (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\nMedium Range: 0.00 to 10.00 mg\/L (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\nHigh Range: 0.0 to 100.0 mg\/L (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading\nMedium Range: ±0.05 mg\/L ±5% of reading\nHigh range: ±0.5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.50 mg\/L (as SDBS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 5540C, Anionic Surfactants as MBAS.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 8.00 mg\/L (as Br\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 400 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e)\nSeawater: 200 to 600 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater: ±10 mg\/L ±5% of reading\nSeawater: ±6% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater: Adaptation of the Oxalate method\nSeawater: Adaptation of the Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L (as Cl⁻)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±6% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Chlorophenol Red method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\nUltra Low Range: 0.000 to 0.500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\nUltra Low Range: 0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\nUltra Low Range: ±0.020 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\nUltra Low Range: 0.000 to 0.500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\nUltra High Range: 0 to 500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\nUltra Low Range: 0.001 mg\/L\nUltra High Range:1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\nUltra Low Range: ±0.020 mg\/L ±3% of reading\nUltra High Range: ±3 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\nFree Chlorine (ULR) \u0026amp; Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-Cl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Cr\u003csup\u003e6+\u003c\/sup\u003e)\nHigh Range: 0 to 1000 µg\/L (as Cr\u003csup\u003e6+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±1 µg\/L ±4% of reading\nHigh Range: ±5 µg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 PCU (Platinum Cobalt Units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Resolution\u003c\/td\u003e\n\u003ctd\u003e1 PCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 PCU ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Colorimetric Platinum Cobalt method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\nHigh range: 0.00 to 5.00 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading\nHigh Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±15% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as F\u003csup\u003e-\u003c\/sup\u003e)\nHigh range: 0.0 to 20.0 mg\/L (as F\u003csup\u003e-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\nHigh Range: ±0.5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 250 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\nMedium Range: 200 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\nHigh Range: 400 to 750 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±5 mg\/L ±4% of reading\nMedium Range: ±7 mg\/L ±3% of reading\nHigh Range: ±10 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA recommended method 130.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, EDTA Colorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Range\u003c\/td\u003e\n\u003ctd\u003e0 to 400 µg\/L (as N\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±4% of full scale reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 12.5 mg\/L (as I\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.600 mg\/L (as Fe)\nHigh Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±8% of reading\nHigh Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the TPTZ Method\nAdaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as Mg\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Mn)\nHigh Range: 0.0 to 20.0 (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±10 µg\/L ±3% of reading\nHigh Range: ±0.2 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN Method\nHigh Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo\u003csup\u003e6+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.000 mg\/L (as Ni)\nHigh Range: 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow range: ±0.010 mg\/L ±7% of reading\nHigh Range: ±0.07 g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN method\nHigh Range: Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0 to 600 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N)\nHigh Range: 0 to 150 mg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e)\nSeawater Ultra Low Range: 0 to 200 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 1 µg\/L; 1 mg\/L\nSeawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±20 µg\/L ±4% of reading\nHigh Range: ±4 mg\/L ±4% of reading\nSeawater\n±10 µg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA Diazotization method 354.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1000 µg\/L (as DEHA)\n0.00 to 1.50 mg\/L (as Carbohydrazide)\n0.00 to 2.50 mg\/L (as Hydroquinone)\n0.00 to 4.50 mg\/L (as ISO-ascorbic acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L (DEHA); 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 µg\/L ±5% of reading (DEHA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the iron reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0.00 to 2.50 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\nHigh range: 0.0 to 30.0 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\nSeawater Ultra Low Range: 0 to 200 µg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0.01 mg\/L; 0.1 mg\/L\nSeawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±0.04 mg\/L ±4% of reading\nHigh Range: ±1 mg\/L ±4% of reading\nSeawater Ultra Low Range: ±5 µg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: Adaptation of the Ascorbic Acid method\nFreshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L (as K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3.0 mg\/L ±7% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Turbidimetric Tetraphenylborate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e)\nHigh Range: 0 to 200 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading\nHigh Range: ±1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method\nHigh Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as SO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Method\u003c\/td\u003e\n\u003ctd\u003eTurbidimetric - Sulfate is precipitated with barium chloride crystals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 5 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003edigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e128 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003ecalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003elog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery \/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0 ℃ (32 to 122.0 °F); 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97 mm (8.1 x 7.0 x 3.8”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI83300 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI83300-01\" target=\"_blank\" rel=\"noopener\"\u003eMultiparameter Benchtop Photometer and pH meter\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871272108401,"sku":"HI83300-02","price":164963.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83300-upper-angle-cover-closed_1.jpg?v=1792646009"},{"product_id":"direct-soil-measurement-ph-portable-meter-hi99121","title":"Direct Soil Measurement pH Portable Meter - HI99121","description":"\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1292d.jpg\" alt=\"pH meter for direct soil measurement\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc215d-fill.png\" alt=\"Maintenance free gel filled electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eRefillable\u003c\/h4\u003e\n\u003cp\u003eTurn cap to create positive head pressure allowing for more reference electrolyte to flow.\u003cbr\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/check-mark.png\" alt=\"Maintenance free gel filled electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eBuilt-In Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eAutomatic compensation of temperature variations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/check-mark.png\" alt=\"Maintenance free gel filled electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAmplified Electrode\u003c\/h4\u003e\n\u003cp\u003eFast,  stable response that is immune to electrical noise due to humidity.\u003c\/p\u003e\n\u003cp\u003eSoil can be acid,  neutral or alkaline,  according to its pH value. Most plants prefer a pH range from 5.5 to 7.5; but some species prefer more acid or alkaline soils. Nevertheless,  every plant requires a particular range of pH,  for optimum growth. \u003cbr\u003e\u003cbr\u003epH strongly influences the availability of nutrients and the presence of microorganisms and plants in the soil. For example,  fungi prefer acidic conditions whereas most bacteria,  especially those supplying nutrients to the plants,  have a preference for moderately acidic or slightly alkaline soils. In fact,  in strongly acidic conditions,  nitrogen fixing and the mineralization of vegetable residual is reduced. Plants absorb the nutrients dissolved in the soil water and the nutrient solubility depends largely on the pH value. Hence,  theavailability of elements is different at different pH levels. \u003cbr\u003e\u003cbr\u003eEach plant needs elements in different quantities and this is the reason why each plant requires a particular range of pH to optimize its growth. For example,  iron,  copper and manganese are not soluble in an alkaline environment. This means that plants needing these elements should theoretically be in an acidic type of soil. Nitrogen,  phosphorus,  potassium and sulfur,  on the other hand,  are readily available in a pH range close to neutrality. Furthermore,  abnormal pH values,  increase the concentration of toxic elements for plants. For example,  in acid conditions,  there can be an excess of aluminum ions in such quantities that the plant cannot tolerate. Negative effects on chemical and physical structure are also present when pH values are too far from neutral conditions (break up of aggregates,  a less permeable and more compact soil). \u003cbr\u003e\u003cbr\u003eThe HI99121 meter features a large multi level LCD screen which displays both pH and temperature readings simultaneously with 0.01 pH resolution and an accuracy of ±0.02 pH. The LCD screen also has indicators for calibration status and stability,  as well as on-screen tutorial messages. The HI99121 has many advanced features that are found in more expensive portable instrumentation including automatic calibration,  buffer recognition, and temperature compensation. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available. The supplied HI12923 is a glass body,  amplified pH electrode with a built-in temperature sensor designed specifically for measuring the pH in soils.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatic Temperature Compensation\u003c\/li\u003e\n\u003cli\u003eOne or two-point automatic calibration\u003c\/li\u003e\n\u003cli\u003eBEPS - Alerts the user of low battery power that could adversely affect readings\u003c\/li\u003e\n\u003cli\u003eCompact,  heavy-duty,  and waterproof\u003c\/li\u003e\n\u003cli\u003eBattery % displayed on start-up\u003c\/li\u003e\n\u003cli\u003eHELP feature,  displays messages on LCD\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eNote: Use the soil auger for stony ground to prevent damaging the glass probe.\u003cbr\u003e             For high accuracy and ensure the soil is wet use the HI7051M soil preparation solution.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI99121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Direct Soil Measurement pH Portable Meter - HI99121\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e -2.00 to 16.00 pH; -2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH; 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.02 pH; ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e automatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic ‐5.0 to 105.0 °C\/23.0 to 221.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003e probe condition indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e ±825 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±1 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -5.0 to 105.0°C \/ 23.0 to 221.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5°C (up to 60°C); ±1.0°C (outside) \/ ±1°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e HI12923 glass body, pre-amplified pH electrode for soil measurement with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e user selectable: after 8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V (3) AAA \/ approximately 1400 hours of continuous use; auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003e IP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 196 g (6.91 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI99121 is supplied with HI12923 pH electrode, HI721319 soil auger, HI7051M soil preparation solution (230 mL), HI70004 pH 4.01 buffer solution sachet (20 mL), HI70007 pH 7.01 buffer solution sachet (20 mL), HI700663 cleaning solution sachet for inorganic soil deposits (20 mL), HI700664 cleaning solution sachet for organic soil deposits (20 mL), 100 mL plastic beaker, batteries, instructions, and a hard carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI99121\"\u003eDirect Soil Measurement pH Portable Meter - HI99121\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871272206705,"sku":"HI99121","price":73140.3,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi99121_c.jpg?v=1792646011"},{"product_id":"soil-testtm-direct-soil-ec-tester-hi98331","title":"Soil Test™ Direct Soil EC Tester - HI98331","description":"\u003cp\u003eThe HI98331 features a stainless steel penetration electrode that provides the ability to take direct measurements in soil. When calibration is needed, simply submerge the electrode tip into calibration solution and and enter calibration mode for automatic 1 point calibration.\u003c\/p\u003e\n\u003cp\u003eElectrolytic conductivity, abbreviated as EC, is a measurement made in which electrical charges of particles in a medium are moved under the influence of a potential difference. EC is a measure of concentration, however, it is non-specic for ion type. An ion is a charged particle present in the solution that contributes to the current flow. Ions are formed when a salt such as sodium chloride is dissolved in water to form particles having electrical charges. Sodium chloride, separates into Na\u003csup\u003e+\u003c\/sup\u003e and Cl\u003csup\u003e-\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eElectrical conductance, the ability of a substance to conduct an electrical current is the reciprocal of electrical resistance. “Conductance” and “Resistance” depend on the geometrical dimensions of the substance being measured. Conductivity and resistivity are “normalized” terms that are used to denote a bulk intrinsic property of a substance. This is the measurement a standardized EC probe on a Conductivity or resistivity meter provides. Conductivity measurements can be used to provide additional industry specific measurements; TDS, Salinity and USP compliant conductivity. Many of Hanna’s meters provide these measurements also.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance:\u003c\/h4\u003e\n\u003ch5\u003eOne-point calibration\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAutomatic calibration to 1413 µS\/cm conductivity standard\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Temperature Compensation (ATC)\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSamples automatically compensated for temperature variations\u003c\/li\u003e\n\u003cli\u003eUses a fixed 2%\/℃ temperature correction coefficient\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eStainless steel penetration electrode\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAllows for direct measurement in soil\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSoil Test™ Direct Soil EC Tester - HI98331\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 4000 µS\/cm; 0.00 to 4.00 mS\/cm (dS\/m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm; 0.01 mS\/cm (dS\/m)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±50 µS\/cm (0 to 2000 µS\/cm), ±300 µS\/cm (2000 to 4000 µS\/cm); ±0.05 mS\/cm (0.00 to 2.00 mS\/cm), ±0.30 mS\/cm (2.00 to 4.00 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at 1.41 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic, temperature coefficient (β) fixed 2% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e\n\u003ctd\u003e114 mm (4.5 “) Stainless steel penetration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 Li-ion approximately 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e50 x 196 x 21 mm (2.0 x 7.7 x 0.9“)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e74 g (2.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98331 is supplied with a stainless steel penetration probe, batteries, and instrument quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98331\" target=\"_blank\" rel=\"noopener\"\u003eSoil Test™ Direct Soil EC Tester - HI98331\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871272239473,"sku":"HI98331","price":12154.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98331-groline-2017.jpg?v=1792646011"},{"product_id":"ascorbic-acid-test-kit-hi3850","title":"Ascorbic Acid Test Kit - HI3850","description":"\u003cp\u003eThe HI3850 is an iodometric chemical test kit that determines the concentration of ascorbic acid from the number of drops of reagent necessary to cause a specific color change in the sample. The HI3850 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 100 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the reagent bottles,  plastic pipettes,  and plastic vessels.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eIodometric method\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThe concentration of ascorbic acid in a sample is easily calculated from the number of drops of reagent HI3850C-0 used.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3850-100 reagent set can be ordered to replace the reagents supplied with the kit. This set comes with 1 (100 mL) bottle HI3850A-0 ascorbic acid reagent A,  1 (25mL) dropper bottle Starch Indicator,  and 1 (100 mL) bottle HI3850C-0 ascorbic acid reagent C.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eSignificance of Use\u003c\/h4\u003e\n\u003cp\u003eAscorbic acid and its sodium,  potassium,  and calcium salts are commonly used as antioxidant food additives.\u003c\/p\u003e\n\u003cp\u003eAscorbic acid (Vitamin C) is added as a flavoring and preservative agent to juice-based beverages. This kit is especially designed for the determination of the content of Vitamin C in beverages. It is based on a drop-count titration and is practical also with intensively colored samples.\u003c\/p\u003e\n\u003cp\u003eThe National Academy of Sciences recommends the consumption of 60 mg of ascorbic acid per day. Vitamin C deficiency,  which typically causes abnormalities in bones and teeth,  was first characterized by sailors in the 18\u003csup\u003eth\u003c\/sup\u003e century. These abnormalities were eliminated by compelling sailors to eat limes,  a source of vitamin c. Many vegetables also contain large quantities of vitamin C,  but ascorbic acid is commonly destroyed by many cooking processes,  and hence citrus fruits are regarded as the most reliable source of vitamin C.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ascorbic Acid Test Kit - HI3850\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAscorbic Acid Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAscorbic Acid Range\u003c\/td\u003e\n\u003ctd\u003e 10-200 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAscorbic Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e 10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAscorbic Acid Method\u003c\/td\u003e\n\u003ctd\u003e Iodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAscorbic Acid Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100 (average)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 519 g (18.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 235x175x115 mm (9.2x6.9x4.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3850 test kit comes with 100 mL bottle HI3850A-0 ascorbic acid reagent A, 1 (25mL) dropper bottle Starch Indicator, 100 mL bottle HI3850C-0 ascorbic acid reagent C, 2 (50mL) calibrated vessels, 1 (3 mL) plastic pipette, 1 (1 mL) plastic pipette, 1 plastic test tube with cap.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3850\"\u003eAscorbic Acid Test Kit - HI3850\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871274533233,"sku":"HI3850","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3850-1200by1200-rgb_1.jpg?v=1792646014"},{"product_id":"glycol-chemical-test-kit-hi3859","title":"Glycol Chemical Test Kit - HI3859","description":"\u003cp\u003eThe HI3859 is a visual chemical test kit that determines the presence or absence of glycol. The HI3859 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents to perform 25 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the reagent bottles and packets, plastic pipettes, and glass vials.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eYes \/ No\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThe presence of glycol in a sample is easily recognized in the form of an intense purple color.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3859-025 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 1 (125 mL) bottle of HI3859A-0 reagent, 25 packets of HI3859B-0 reagent, and 25 packets of HI3859C-0 reagent.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eEthylene glycol is widely used as a coolant and antifreeze. Its presence in motor oil or tranmission fluid is an indication of a perforated engine block or of a leakage in the cooling systems. The Hanna Glycol test kit can be used for water as well as oil samples to determine traces of ethylene glycol and other 1, 2 glycols above 30 mg\/L (ppm). Ethylene glycol and other 1, 2 glycols are determined by a two step reaction:\u003c\/p\u003e\n\u003cp\u003eStep 1: Glycol is oxidized to two carbonyl groups under acidic conditions.\u003c\/p\u003e\n\u003cp\u003eStep 2: The carbonyl groups react with the indicator in the HI3859C-0 reagent powder packet to give a colored solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eGlycol Chemical Test Kit - HI3859\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlycol Measurement Type\u003c\/td\u003e\n\u003ctd\u003eOther (Visual)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlycol Range\u003c\/td\u003e\n\u003ctd\u003eThe test detects traces of glycol above 30 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlycol Method\u003c\/td\u003e\n\u003ctd\u003eAppearance of color\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlycol Number of Tests\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e380 g (13.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235x175x115 mm (9.2x6.9x4.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3859 test kit comes with 125 mL glycol reagent A, 25 packets glycol reagent B, 25 packets glycol reagent C, 25 mL glycol standard 0.025%, 3 mL plastic pipette, 1 mL plastic pipettes (25), 10 mL glass vials with caps (2), and brush.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3859\" target=\"_blank\" rel=\"noopener\"\u003eGlycol Chemical Test Kit - HI3859\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871274598769,"sku":"HI3859","price":14760.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3859_1200_1.jpg?v=1792646016"},{"product_id":"phenols-test-kit-with-checker-disc-hi3864","title":"Phenols Test Kit with Checker Disc - HI3864","description":"\u003cp\u003eThe HI3864 is a chemical test kit that determines the phenol concentration in two ranges: 0.00 to 1.00 mg\/L (LR) and 0.5 to 5.0 mg\/L (HR). The HI3864 is supplied with all of the necessary reagents and equipment to perform both analyses,  including the Checker® disc. The Checker® disc makes concentration determination more accurate and easier than a typical color comparator.The test kit contains enough reagents to perform 100 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the glass vials,  reagent packets,  and Checker® disc.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eReadings from 0.00 to 1.00 mg\/L are determined to 0.02 mg\/L resolution.\u003c\/li\u003e\n\u003cli\u003eReadings from 0.5 to 5.0 mg\/L are determined to 0.1 mg\/L resolution.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3864-100 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 100 packets of HI3864A-0 and 100 packets of HI3864B-0.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSignificance of Use\u003c\/h4\u003e\n\u003cp\u003ePhenols are widely used in pharmaceuticals,  dyes and indicators,  and as general disinfectants. They may occur in household and industrial wastewaters and in natural waters; they can also enter potable water supplies and chlorination of such waters results in malodorous chlorophenol products that are detectable from 0.001 mg\/L (1ppb). The Hanna colorimetric method determines phenol and all ortho and para substituted phenols. Since substitution generally lowers the response,  the readable value obtained by this method is the minimum concentration of phenolic compounds present. Natural water usually contains less than 0.001 mg\/L of phenols,  but sometimes values up to 0.02 mg\/L (20 ppb) also occur. Since the concentration of phenols in wastewater is generally subjected to biological and chemical degradation,  preserve samples in the refrigerator and analyze within four hours after collection.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3864\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Phenols Test Kit with Checker Disc - HI3864\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhenols Measurement Type\u003c\/td\u003e\n\u003ctd\u003e Checker Disc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhenols Range\u003c\/td\u003e\n\u003ctd\u003e Low Range:0.00 to 1.00 mg\/L \u003cbr\u003eHigh Range: 0.5 to 5.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhenols Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.02 mg\/L (0.00 to 1.00 mg\/L range); 0.1 mg\/L (0.5 to 5.0 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhenols Method\u003c\/td\u003e\n\u003ctd\u003e aminoantipyrine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhenols Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 573 g (20.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 235x175x115 mm (9.2x6.9x4.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3864 test kit comes with HI3864A-0 reagent (100 packets), HI3864B-0 reagent (100 packets), checker disc with LR and HR discs, glass vials with caps (2), and a mirror.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3864\"\u003ePhenols Test Kit with Checker Disc - HI3864\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871274697073,"sku":"HI3864","price":16655.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3864.jpg?v=1792646017"},{"product_id":"advanced-ph-orp-benchtop-meter-hi6221-02","title":"Advanced pH\/ORP Benchtop Meter- HI6221-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eLaboratory\u003c\/h2\u003e\n\u003cp\u003eMeasure pH\/mV (pH) or mV\/Rel. mV (ORP) with Temperature\u003c\/p\u003e\n\u003cp\u003eHI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH \/ ORP measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the benchtop meter is delivered with Hanna Instruments HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe.\u003c\/p\u003e\n\u003cp\u003eHI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction reference and HT glass design allow the HI1131B to be used in a wide variety of applications including samples with metals and elevated temperatures. Probe connection to the unit is secured through a galvanically isolated BNC connection. HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221_front-rear.png\" alt=\"front back\" width=\"1250\" height=\"691\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThis system responds to a complex range of measurement and monitoring requirements, providing accuracy, reproducibility, and reliability. HI6221 is supplied with an electrode holder that has a flexible arm. The holder can be mounted quickly and provides secure support for electrodes while taking measurements in sample containers.\u003c\/p\u003e\n\u003ch4\u003eUser interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003cli\u003eThe user can select between five different views:\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH\/mV (pH) or mV\/Rel.mV (ORP) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor and system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic (using temperature probe) or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for pH\/ORP measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e5-point pH calibration with automatic recognition for standard buffers (Hanna and NIST buffers)\u003c\/li\u003e\n\u003cli\u003eChoice of standard or custom buffers for calibration\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLogging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnectivity features \u0026amp; services\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection\u003c\/li\u003e\n\u003cli\u003eUSB type A for USB stick, keyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHelp section for meter guidance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eVideo support presentation of main functionalities\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eCustomize calibration options such as Last Calibration, Automatic, semi-automtic or manual calibration, First Calibration Point, daily or periodic Calibration Reminder, and buffer Groups.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_08_Image_0007.jpg\" alt=\"\" width=\"460\" height=\"276\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_02_Image_0001.png\" alt=\"\" width=\"450\" height=\"450\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eCapacitive touch screen with multi-touch support\u003c\/h2\u003e\n\u003cp\u003eThe benchtop unit has a 7-inch color display with 800 x 480p resolution. The capacitive, multi-touch screen supports video playback and data plotting.\u003c\/p\u003e\n\u003ch2\u003eSystem Menu key\u003c\/h2\u003e\n\u003cp\u003eThis key will enter the system menu where User accounts, System Settings, and Logging can be configured. The Help menu is also accessed on the system menu screen.\u003c\/p\u003e\n\u003ch2\u003eMeasurement setup menu\u003c\/h2\u003e\n\u003cp\u003eOpens sensor setup parameters.\u003c\/p\u003e\n\u003ch2\u003eDirect\/Autohold readings\u003c\/h2\u003e\n\u003cp\u003eWhen Direct\/Autohold is selected, measurement reading is held on display when measurement stability is reached. This option removes the subjective nature of stability as a measurement that has not reached equilibrium will not be used.\u003c\/p\u003e\n\u003cp\u003eWhen not selected, sample measurements are displayed continuously.\u003c\/p\u003e\n\u003ch4\u003eHI6221 is supplied with:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHI1131B pH electrode; HI7662-TW temperature probe\u003c\/li\u003e\n\u003cli\u003epH calibration starter kit consisting of:\u003cul\u003e\n\u003cli\u003epH 4.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 7.01 buffer solution sachet (4 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 10.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHI700601 electrode cleaning solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eHI7082 3.5M KCl electrolyte solution (30 mL)\u003c\/li\u003e\n\u003cli\u003eHI764060 electrode holder\u003c\/li\u003e\n\u003cli\u003eCapillary pipette\u003c\/li\u003e\n\u003cli\u003e24 VDC power adapter\u003c\/li\u003e\n\u003cli\u003eUSB-C to USB-A cable\u003c\/li\u003e\n\u003cli\u003eQuick reference guide with instrument quality certificate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last signiﬁcant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last signiﬁcant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV oﬀset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Calibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003epH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom buﬀers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration 1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOﬀset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDaily: 0 m in. to 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003ePeriodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect; Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Isopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (pH, mV, Rel.mV, Abs.mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eTemperature, Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eLast calibration date, electrode oﬀset, average slope, and electrode condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003epH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle \/ Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003eUsers Up to 9 users and adm in. account (default):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP \/ Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (2.65 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6221-02\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871319884145,"sku":"HI6221-02","price":122546.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221-head-on-700x700-cd07ed0c-fd8c-42df-a0a8-112410be6851_4_2.jpg?v=1792646147"},{"product_id":"advanced-conductivity-benchtop-meter-hi6321","title":"Advanced Conductivity Benchtop Meter - HI6321-02","description":"\u003cp\u003eHI6321 is a streamlined Conductivity\/Resistivity\/TDS\/Salinity\/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity\/ resistivity\/TDS\/salinity probe.\u003c\/p\u003e\n\u003cp\u003eRecommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures.\u003c\/li\u003e\n\u003cli\u003eStandard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for \u0026gt;1Mohm.cm resistivity measurements.\u003c\/li\u003e\n\u003cli\u003eNatural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe result is reliable electrolytic conductivity (EC), TDS (Total Dissolved Solids), resistivity, or Seawater Salinity in percent, psu, or ppt units.\u003c\/p\u003e\n\u003cp\u003eTDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement.\u003c\/p\u003e\n\u003cp\u003eSal psu: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 ℃ and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g\/Kg water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 ℃.\u003c\/p\u003e\n\u003cp\u003eSal ppt: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g\/L and covers 10 to 31 ℃ temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 ℃ and an approximate salinity value of 35 in seawater.\u003c\/p\u003e\n\u003cp\u003eSal %: in this scale 100% salinity is equivalent to roughly 10% solids.\u003c\/p\u003e\n\u003ch2\u003eUser interface\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThe user can select between five different views:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMeasurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure µS\/cm, mS\/cm (Conductivity); ω·cm, kω·cm, Mω·cm (Resistivity); ppm, ppt (TDS); ppt, PSU,\n% (Salinity) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor\nand system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for conductivity measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCalibration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStandard single point salinity calibration in 100% salinity standard, with the reading salinity scale set to %\u003c\/li\u003e\n\u003cli\u003eStandard single or multiple conductivity calibration with standards\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogging\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConnectivity features \u0026amp; services\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection o USB type A for USB stick,\nkeyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 µS\/cm; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 µS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±1 Ω·cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water 0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration points\u003c\/td\u003e\n\u003ctd\u003eAuto standard recognition \/ User standard, Single Point \/ Multi Point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Standard solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 µS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling\u003c\/td\u003e\n\u003ctd\u003erate 1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information Last calibration date, oﬀset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (26.5 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6321\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322734961,"sku":"HI6321-02","price":148128.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6321-right-facing-700x700-d4924805-c4b9-4224-b973-d8a72a57f915.jpg?v=1792646150"},{"product_id":"multiparameter-portable-ph-ec-do-waterproof-meter-hi98199","title":"Multiparameter Portable pH\/EC\/DO Waterproof Meter - HI98199","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98199_with-boot-HI829113_angle-pH.jpg\" alt=\"HI98199\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSuperior Durability\u003c\/h5\u003e\n\u003cp\u003eAn IP67-rated, waterproof meter means that this meter is built to withstand immersion in 1m of water for up to 30 minutes. The meter has rubber gaskets sealing the battery compartment and connectors in epoxy to prevent any water from entering and damaging the internal electronics from water. With an ergonomic design and waterproofing the HI98199 will fit well in your hand and provides years of use.\u003c\/p\u003e\n\u003cp\u003eNote: The meter is displayed with an optional shockproof rubber boot for additional protection.\u003c\/p\u003e\n\u003ch5\u003eDot Matrix Display\u003c\/h5\u003e\n\u003cp\u003eThe large dot matrix display provides for an intuitive user interface in which the user is guided through any setup configuration or calibration. A dedicated help key provides for contextual help that is related to the screen being viewed at the time. The dot matrix display is viewable under bright sunlight and has a backlight for when viewing under poor lighting conditions.\u003c\/p\u003e\n\u003ch5\u003eAlphanumeric Keypad\u003c\/h5\u003e\n\u003cp\u003eThe low profile vulcanized rubber keypad along with virtual keys provide for a quick entry of password, user ID and sample site. The configuration of the meter can be password protected to prevent any unwanted changes. The user and sample ID are stored with any logged readings and can be transferred to a PC for analysis or long term record keeping.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI827113_HI763093_HI764103_HI98199_Group_3.jpg\" alt=\"Digital probes for HI98199\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eDigital Probes\u003c\/h5\u003e\n\u003cp\u003eHI98199 uses highly advance digital electrodes featuring a built-in microprocessor that performs the measurements. When these probes are connected to the meter they are automatically detected and the meter is updated to display the appropriate parameter. These digital electrodes also feature a quick connect DIN connector that provides a secure waterproof connection.\u003c\/p\u003e\n\u003ch5\u003eFlexibility\u003c\/h5\u003e\n\u003cp\u003eHI98199 is supplied with a pH\/temperature probe. The meter can always be upgraded to measure dissolved oxygen or conductivity by purchasing the compatible probe.\u003c\/p\u003e\n\u003ch5\u003eTraceability\u003c\/h5\u003e\n\u003cp\u003eThe calibration information for a connected probe can be viewed at anytime using the dedicated Good Laboratory Practice (GLP) button on the meter. The calibration information includes the date, time, calibration points and probe characteristic.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98199_Connection_angle.jpg\" alt=\"HI98199 USB\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eQuick Connect Digital Probe Connection with Auto-Sensor Recognition\u003c\/h5\u003e\n\u003cp\u003eThe Quick Connect DIN connector is designed for quick and secure waterproof connection. The meter will automatically recognizes the probe attached and uploads stored calibration data. Each probe then transmits readings digitally to the meter overcoming challenges faced with standard analog probes.\u003c\/p\u003e\n\u003ch5\u003eUSB-C Port for Data Transfer\u003c\/h5\u003e\n\u003cp\u003eThe USB-C port is used for transferring logged data to a PC using Windows compatible software. The HI98199 can log up to 45, 000 samples either by interval logging at a set time period or by log on demand of an individual reading.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Pressure Transducer\u003c\/h5\u003e\n\u003cp\u003eThe HI98199 has a built in pressure transducer for the measurement of barometric pressure. The pressure measurement can be viewed with any probe connected but the measurement is used when measuring dissolved oxygen for automatic atmospheric pressure compensation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMultiparameter Portable pH\/EC\/DO Waterproof Meter - HI98199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one, two, or three points of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading or ±2 µS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic single-point, with six standard solutions (84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 200.0 ppt (g\/L) (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L) whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e25 °C or 20 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Type\u003c\/td\u003e\n\u003ctd\u003efour ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Multi-range Measurement Modes\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ0, σ15\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω cm; 0.1 kΩ cm; 0.0001 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003egalvanic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0%: ±1.5% of reading or ±1.0% whichever is greater\n300.0 to 500.0%: ±3% of reading\n0.00 to 30.00 ppm (mg\/L) ±1.5% of reading or ±0.10 ppm (mg\/L), whichever is greater\n30.00 ppm (mg\/L) to 50.00 ppm (mg\/L): ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two points at 0, 100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00 °C; 23.00 to 131.00 °F; 268.15 to 328.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C; 0.01 °F; 0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15 °C; ±0.27 °F; ±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 55 °C (23 to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003econtinuous logging or log-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e45000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Interval\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003evia USB-C with Hanna software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eNot used (disabled), 5, 10, 15, 20, 30, 60 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Timeout Reminder\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003edot matrix\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 400 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185.0 x 93.0 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98199 is supplied with the HI829113 pH digital probe with 4m (13’) cable, pH calibration solution sachets, PC software, micro USB cable, batteries, quality certificate, and instruction manual in a rugged carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98199\" target=\"_blank\" rel=\"noopener\"\u003eMultiparameter Portable pH\/EC\/DO Waterproof Meter - HI98199\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322767729,"sku":"HI98199","price":101000.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98199_with_hi829113_1.jpg?v=1792646150"},{"product_id":"waterproof-phep5-ph-temperature-tester-hi98128","title":"Waterproof pHep®5 pH\/Temperature Tester - HI98128","description":"\u003cp\u003eThe pHep®5 is a waterproof pH tester with a 0.01 pH resolution and an accuracy of ±0.5 pH. The one, two, or three-point calibration is automatic to two selectable buffer sets (4.01, 7.01 and 10.01 or 4.01, 6.86, and 9.18). The pHep®5 also features a replaceable electrode with a stainless steel round connector. The HI73127 replacement pH electrode also features an extractable cloth that is used to renew the junction by extracting ⅛” of the cloth junction to expose a new portion. Any clogging that was present is cleared and the response time will be back to normal, extending the life of the pH electrode.\u003c\/p\u003e\n\u003ch4\u003eFeatures\u003c\/h4\u003e\n\u003cp\u003eWaterproof casing designed to float if dropped in water\u003c\/p\u003e\n\u003cp\u003eExpanded pH Range from -2.0 to 16.0 pH\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation, displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eStability indicator confirms the reading has stabilized\u003c\/p\u003e\n\u003cp\u003eHOLD button for easier measurement recording\u003c\/p\u003e\n\u003cp\u003eBattery Error Prevention System (BEPS)\u003c\/p\u003e\n\u003cp\u003eAuto-off to preserve battery life\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWaterproof pHep\u003csup\u003e®\u003c\/sup\u003e5 pH\/Temperature Tester - HI98128\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one, two, or three points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 60.0°C \/ 23.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 replaceable pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 300 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-5 to 50°C (23 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98128 (pHep\u003csup\u003e®\u003c\/sup\u003e5) is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98128\" target=\"_blank\" rel=\"noopener\"\u003eWaterproof pHep\u003csup\u003e®\u003c\/sup\u003e5 pH\/Temperature Tester - HI98128\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322898801,"sku":"HI98128","price":13266.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98128.jpg?v=1792646152"},{"product_id":"advanced-dissolved-oxygen-benchtop-meter-with-optical-do-probe-opdo-hi6421","title":"Advanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo®) - HI6421-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHI6421 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated module designed for fresh and saltwater measurements of dissolved oxygen.\u003c\/p\u003e\n\u003cp\u003eHI6421 includes Hanna's HI7641133 optical dissolved oxygen probe (opdo®) that is based on the principle of fluorescence quenching. An immobilized Pt-based luminophore is excited by the light of a blue LED and emits a red light. As oxygen interacts with the luminophore it reduces the intensity and lifetime of the luminescence. The lifetime of the luminescence is measured by a photodetector and is used to calculate the dissolved oxygen concentration.\u003c\/p\u003e\n\u003cp\u003eThe probe is fitted with easy to use Smart Caps (HI764113-1) which lock in place and contain pre-loaded calibration coefficients that are automatically transmitted to the probe. The Smart Cap features an immobilized O₂ sensitive luminophore with rugged insoluble black oxygen permeable protective layer. Over time, the sensor’s optical components can age but are compensated for by using the reference signal to compensate the measuring path. As a result, the sensor provides accurate DO measurements over long periods of time without the need for frequent calibration. Concentration measured. Additional features include built-in methods and calculations for the measurement of BOD (Biological Oxygen Demand), OUR (Oxygen Uptake Rate), and SOUR (Specific Oxygen Update Rate). Pressure compensation is done automatically (built-in barometer) or users have the option to manually enter required value. Pressure is displayed in user-configurable units: mmHg, mbar, kPa, inHg, psi, atm.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6321_1p0_1222_WEB.jpg\" alt=\"systemUI\" width=\"700\" height=\"537\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch4\u003eUser interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThe user can select between five different views:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure %Sat, mg\/L, ppm (DO); mg\/L, ppm (BOD); mg\/L (OUR); ppm, mg\/L (SOUR)\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the\nsensor and system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/auto-hold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eOne or two points calibration at 0% and\/or 100% saturation\u003c\/li\u003e\n\u003cli\u003eSingle point manual calibration in mg\/L or % saturation using a reference method\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLogging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, auto-hold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and auto-hold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnectivity features \u0026amp; services\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data ta USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection\u003c\/li\u003e\n\u003cli\u003eUSB type A for USB stick, keyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHelp section for meter guidance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eVideo support presentation of main functionalities\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eOrdering Information:\u003c\/h2\u003e\n\u003cp\u003eHI6421 is supplied with HI7641133 optical dissolved oxygen probe (opdo®); HI764060 electrode holder; capillary pipette; 24 VDC power adapter; USB-C to USB-A cable; probe quality certificate; quick reference guide with instrument quality certificate.\u003c\/p\u003e\n\u003ch2\u003eAccessories:\u003c\/h2\u003e\n\u003cp\u003eHI7641133 optical dissolved oxygen probe (opdo®)\u003cbr\u003e\nHI764113-1 Smart cap with O-ring\u003cbr\u003e\nHI764113-2 Calibration\/storage vessel\u003cbr\u003e\nHI764113-3 Stainless steel protective shield\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\u003cp\u003e \u003c\/p\u003e\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo\u003csup\u003e®\u003c\/sup\u003e) - HI6421\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO meter Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 600.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Meter Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 90.00 mg\/L (ppm) concentration; 0.0 to 500.0 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L (ppm); 0.1 % saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO (HI7641133 Optical probe) Accuracy\u003c\/td\u003e\n\u003ctd\u003efrom 0.00 to 20.00 mg\/L (ppm) 1.5 % of reading or ± 0.01 mg\/L (ppm), whichever is greater from 20.00 to 50.00 mg\/L (ppm) ±5 % of reading from 0.0 to 200.0 % saturation ± 1.5 % of reading or ± 0.1 %, whichever is greater from 200.0 to 500.0 % saturation ±5 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Range\u003c\/td\u003e\n\u003ctd\u003e450 to 850 mmHg; 600 to 1133 mBar; 60 to 133 kPa; 17 to 33 inHg; 8.7 to 16.4 psi; 0.592 to 1.118 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mmHg; 1 mBar; 1 kPa; 1 inHg; 0.1 psi; 0.001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric Pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point ±3 mmHg ±1 least signiﬁcant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Points\u003c\/td\u003e\n\u003ctd\u003eOne or two points automatic calibration at 100% (8.26 mg\/L) and 0% (0 mg\/L). Single point manual using a value entered by the user in % saturation or mg\/L.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Standards\u003c\/td\u003e\n\u003ctd\u003e0 and 100% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic from 0 to 70 PSU (manually set) 0.0 to 70.0 % \/ 0.0 to 45.0 g\/L \/ 0.0 to 42.0 psu\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Isopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (DO, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Simple\u003c\/td\u003e\n\u003ctd\u003eGLP Basic view information Last calibration date, oﬀset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Full\u003c\/td\u003e\n\u003ctd\u003eGLP Simple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds \/ 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP \/ Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.2 kg (26.5 lbs.)1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6421\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Dissolved Oxygen Benchtop Meter with Optical DO Probe (opdo\u003csup\u003e®\u003c\/sup\u003e) - HI6421\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871326273905,"sku":"HI6421-02","price":215460.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6421.jpg?v=1792646160"},{"product_id":"free-chlorine-checker-hc-hi701","title":"Free Chlorine Checker® HC - HI701","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI701 Checker®HC (Handheld Colorimeter) is a simple, accurate and cost effective way to measure free chlorine. Free chlorine is the active form of chlorine used for disinfection of drinking water, swimming pools and spas, and vegetable rinse water. Free chlorine in water is also harmful to a reverse osmosis membrane and needs to be monitored for removal from source water prior to being used. Designed as a more accurate alternative to chemical test kits, the HI701 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFor use with freshwater samples\u003c\/li\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Pools and Spas\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI701\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of USEPA method 330.5. The reaction between free chlorine and the DPD reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI701 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, free chlorine reagent starter kit (reagents for 6 tests), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI701\" target=\"_blank\" rel=\"noopener\"\u003eFree Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI701\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871346229617,"sku":"HI701","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi701-checkerhc-front.jpg?v=1792646208"},{"product_id":"copper-high-range-checker-hc","title":"Copper High-Range Checker® HC - HI702","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI702 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure high ranges of copper. Designed as a more accurate alternative to chemical test kits, the HI702 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water quality, Environmental, Plating, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI702\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCopper High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the EPA method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI702 Checker\u003csup\u003e®\u003c\/sup\u003eHC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI702\" target=\"_blank\" rel=\"noopener\"\u003eCopper High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871346393457,"sku":"HI702","price":7014.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi702-checkerhc-front.jpg?v=1792646210"},{"product_id":"phosphorus-high-range-checkerhc-hi706","title":"Phosphorus High-Range Checker®HC - HI706","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI706 Checker®HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure phosphorus. Common in natural systems, such as lakes, oceans, and soil, phosphorus is an essential element in plant growth. However, when present in large concentrations, phosphorus can cause excessive microorganism and algae growth, as well as corrosion to piping systems. Designed as a more accurate alternative to chemical test kits, the HI706 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Aquariums\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePhosphorus High-Range Checker\u003csup\u003e®\u003c\/sup\u003eHC - HI706\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 15.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Heteropolymolybdenum Blue method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI706 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, phosphorus HR reagent starter kit for 20 tests (1 bottle of phosphorus reagent A, 20 packets of phosphorus HR reagent B), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI706\" target=\"_blank\" rel=\"noopener\"\u003ePhosphorus High-Range Checker\u003csup\u003e®\u003c\/sup\u003eHC - HI706\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871367364977,"sku":"HI706","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi706-checkerhc-front.jpg?v=1792646271"},{"product_id":"waterproof-portable-ph-temperature-meter-hi991001","title":"Waterproof Portable pH\/Temperature Meter - HI991001","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI991001 meter features a large multi level LCD screen which displays both pH and temperature readings simultaneously with 0.01 pH resolution and an accuracy of ±0.02 pH. The LCD screen also has indicators for calibration status and stability, as well as on-screen tutorial messages. The HI991001 has many advanced features that are found in more expensive portable instrumentation including automatic calibration, buffer recognition, and temperature compensation. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1296.jpg\" alt=\"HI1296D\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eHI12963 pH Electrode with Quick Connect DIN Connector\u003c\/h2\u003e\n\u003cp\u003eThe HI991001 is supplied with the pre-amplified titanium body pH\/temperature electrode. The titanium body is resistant to many aggressive chemicals including those used in plating and chemical manufacturing. The titanium body acts as a matching pin that, together with the built-in amplifier, will help reduce the effects of electrical noise on the high impedance pH measurement. Examples of sources of electrical noise include rectifiers, motors and ballasts.\u003c\/p\u003e\n\u003cp\u003eThe HI12963 pH electrode also features an extractable cloth junction. The extractable cloth junction of the HI12963 allows for the renewing of the junction. Simply extract ⅛\" of the junction by pulling on the junction will expose a new portion. Any clogging that was present will be cleared and the response time will be back to normal extending the life of the pH electrode.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eTitanium body that is resistant to harsh chemicals\u003c\/li\u003e\n\u003cli\u003ePre-amplified and matching pin for resistance to electrical noise\u003c\/li\u003e\n\u003cli\u003eExtractable cloth junction to clear any clogging\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature sensor for automatic temperature compensated readings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch5\u003eWaterproof\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDesigned to float if accidentally dropped in a tank\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eExpanded pH Range\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003epH range is from -2.00 to 16.00 pH\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Two-Point Calibration\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eOne or two-point calibration is automatic to two selectable buffer sets (4.01, 7.01 and 10.01 or NIST 4.01, 6.86, and 9.18).\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll readings are compensated for variations in temperature\u003c\/li\u003e\n\u003cli\u003eTemperature displayed in ℃ or ℉ along with pH reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eStability Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHOLD button\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes reading on the display to allow recording of measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBEPS (Battery Error Prevention System)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBattery % level at startup\u003c\/h5\u003e\n\u003ch5\u003eLow Battery Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-Off\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeter automatically shuts off after 8 minutes of non-use to maximize battery life\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI991001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWaterproof Portable pH\/Temperature Meter - HI991001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH; -2.0 to 16.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH; 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH; ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic ‐5.0 to 105.0 °C\/23.0 to 221.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eprobe condition indicator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Sensor Check\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±825 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mV (pH‐mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 80.0°C \/ 23.0 to 176.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C (up to 60°C); ±1.0°C (outside) \/ ±1°F (up to 140°F); ±2.0°F (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI12963 pre-amplified pH probe with internal temperature sensor, quick connect DIN connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: after 8 min, 60 min or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (3) AAA \/ approximately 1400 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e154 x 63 x 30 mm (6.1 x 2.5 x 1.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e196 g (6.91 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI991001 is supplied with HI12963 pH probe with internal temperature sensor, HI70004 pH 4.01 buffer sachet (20 mL x1), HI70007 pH 7.01 buffer sachet (20 mL x1), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL beaker (1), calibration certificates for both meter and probe, batteries, instructions, and rugged thermoformed carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI991001\" target=\"_blank\" rel=\"noopener\"\u003eWaterproof Portable pH\/Temperature Meter - HI991001\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871368151409,"sku":"HI991001","price":57977.1,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi991001_c_manual.jpg?v=1792646279"},{"product_id":"nitrite-low-range-checker-hc-hi707","title":"Nitrite Low-Range Checker® HC-HI707","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI707 Checker® HC (Handheld Colorimeter) provides a simple,  accurate and cost effective way to measure nitrite. As an intermediate part of the nitrogen cycle,  nitrites are present in a variety of sources,  from drinking water to industrial water.  Due to the harmful effects to the environment and aquatic life,  nitrite levels must be closely monitored.  Designed as a more accurate alternative to chemical test kits,  the HI707 provides quick,  accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size,  big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality,  Environmental,  Education,  Aquaculture,  Boiling and Cooling Towers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrite Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC-HI707\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 600 ppb NO₂-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 ppb\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±20 ppb ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003e adaptation of the EPA Diazotization method 354.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e LED @ 470 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e silicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e (1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI707 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, nitrite LR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI707\"\u003eNitrite Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC-HI707\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871368380785,"sku":"HI707","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi707-checkerhc-front.jpg?v=1792646281"},{"product_id":"nitrite-high-range-checker-hc-hi708","title":"Nitrite High-Range Checker® HC - HI708","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI708 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure nitrite. As an intermediate part of the nitrogen cycle, nitrites are present in a variety of sources, from drinking water to industrial water. Due to the harmful effects to the environment and aquatic life, nitrite levels must be closely monitored. Designed as a more accurate alternative to chemical test kits, the HI708 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Aquaculture, Boiling and Cooling Towers\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI708\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eNitrite High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI708\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Ferrous Sulfate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 575 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI708 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, nitrite HR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI708\" target=\"_blank\" rel=\"noopener\"\u003eNitrite High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI708\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871384928625,"sku":"HI708","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi708-checkerhc-front.jpg?v=1792646310"},{"product_id":"manganese-high-range-checker-hc-hi709","title":"Manganese High-Range Checker® HC - HI709","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI709 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure manganese. Designed as a more accurate alternative to chemical test kits, the HI709 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water quality, Environmental, Plating, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eManganese High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI709\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading ± 0.2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method. The reaction between manganese and reagents causes a pink tint in the sample\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI709 Checker\u003csup\u003e®\u003c\/sup\u003eHC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI709\" target=\"_blank\" rel=\"noopener\"\u003eManganese High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI709\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871387615601,"sku":"HI709","price":7014.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi709-checkerhc-front.jpg?v=1792646316"},{"product_id":"total-chlorine-checker-hc-hi711","title":"Total Chlorine Checker® HC - HI711","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI711 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure total chlorine. Chlorine is a popular disinfectant used in municipal water, fruits and vegetables, as well as equipment in the food and beverage industry. Though beneficial in destroying pathogens, levels greater than 4 parts per million (ppm) is harmful to humans and therefore, must be monitored. Designed as a more accurate alternative to chemical test kits, the HI711 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Education, Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI711\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 ppm ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of USEPA method 330.5, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter two minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI711 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, total chlorine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI711\" target=\"_blank\" rel=\"noopener\"\u003eTotal Chlorine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI711\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871388270961,"sku":"HI711","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi711-checkerhc-front.jpg?v=1792646324"},{"product_id":"phosphate-low-range-checker-hc-hi713","title":"Phosphate Low-Range Checker® HC - HI713","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI713 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure phosphate. Phosphate is a common food additive that enhances flavor and acts as a buffering agent. Important for growth and development of plant roots, phosphate is also present in fertilizers. However, high concentrations of phosphates are detrimental to the environment; for this reason, it is closely monitored in natural and municipal waters. Designed as a more accurate alternative to chemical test kits, the HI713 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Aquaculture, Education, Agriculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePhosphate Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI713\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.50 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, Ascorbic-Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter three minutes of non-use and two minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI713 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, phosphate LR reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI713\" target=\"_blank\" rel=\"noopener\"\u003ePhosphate Low-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI713\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871388533105,"sku":"HI713","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi713-checkerhc-front.jpg?v=1792646328"},{"product_id":"bromine-checker-hc-hi716","title":"Bromine Checker® HC - HI716","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI716 Checker® HC (Handheld Colorimeter) provides a simple,  accurate and cost effective way to measure bromine.  Introduced as an alternative to chlorine,  the use of bromine as a sanitizer is increasing in use in many countries.  Bromine is less volatile and has more effective results above a pH of 7.4,  but is an overall slower acting disinfectant. Designed as a more accurate alternative to chemical test kits,  the HI716 provides quick,  accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size,  big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality,  Industrial,  Municipal Water,  Pool and Spa\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Bromine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI716\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 8.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.08 ppm ±5% of reading @ 25 ℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003e adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method. The reaction between bromine and the reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e LED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e silicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e (1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 86.0mm x 61mm x 37.5mm (3.4 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI716 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, bromine reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI716\"\u003eBromine Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI716\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390466417,"sku":"HI716","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi716-checkerhc-front.jpg?v=1792646334"},{"product_id":"phosphate-high-range-checker-hc-hi717","title":"Phosphate High-Range Checker® HC - HI717","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI717 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost effective way to measure phosphate. Phosphate is a common food additive that enhances flavor and acts as a buffering agent. Important for growth and development of plant roots, phosphate is also present in fertilizers. However, high concentrations of phosphates are detrimental to the environment; for this reason, it is closely monitored in both natural and municipal water systems. Designed as a more accurate alternative to chemical test kits, the HI717 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Aquaculture, Education, Industrial, Agriculture\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePhosphate High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI717\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 ppm ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Heteropolymolybdenum Blue method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI717 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, phosphate HR reagent starter kit for 20 tests (1 bottle of phosphate HR reagent A, 20 packets of phosphate HR reagent B), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI717\" target=\"_blank\" rel=\"noopener\"\u003ePhosphate High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI717\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390597489,"sku":"HI717","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi717-checkerhc-front.jpg?v=1792646336"},{"product_id":"magnesium-hardness-checker-hc-hi719","title":"Magnesium Hardness Checker® HC - HI719","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI719 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure magnesium hardness. Designed as a more accurate alternative to chemical test kits, the HI719 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water quality, Environmental, Plating, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI719\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMagnesium Hardness Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI719\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading ± 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, EDTA colorimetric method. The reaction between magnesium and reagents causes a reddish-violet tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5 mm (3.4 in. x 2.4 in. x 1.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI719 Checker\u003csup\u003e®\u003c\/sup\u003eHC is supplied with 2 cuvettes and caps, reagent starter kit (50 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI719\" target=\"_blank\" rel=\"noopener\"\u003eMagnesium Hardness Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI719\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871390957937,"sku":"HI719","price":7014.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi719-checkerhc-front.jpg?v=1792646340"},{"product_id":"calcium-hardness-checker-hc","title":"Calcium Hardness Checker® HC - HI720","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI720 Checker®HC (Handheld Colorimeter) is a simple, accurate, and cost effective way to measure calcium. Designed as a more accurate alternative to chemical test kits, the HI720 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water quality, Environmental, Plating, Education\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI720\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCalcium Hardness Checker\u003csup\u003e®\u003c\/sup\u003e HC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5% of reading ± 0.20 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eadaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method. The reaction between calcium and reagents causes a reddish-violet tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI720 Checker\u003csup\u003e®\u003c\/sup\u003eHC is supplied with 2 cuvettes and caps, reagent starter kit (6 packets of reagent), 1 X 1.5X AAA battery, and an instruction manual. *CALcium Hardness Checker\u003csup\u003e®\u003c\/sup\u003e HC\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391220081,"sku":"HI720","price":7014.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi720-checkerhc-front.jpg?v=1792646343"},{"product_id":"iron-checker-hc-hi721","title":"Iron Checker® HC - HI721","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI721 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure iron. Naturally present in water in low concentrations, iron may affect the taste of water, as well as stain both laundry and household appliances. Also an indicator of corrosion, iron is monitored in industrial plants and water cooling and heating systems. Designed as a more accurate alternative to chemical test kits, the HI721 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Education, Industrial, Municipal Water, Aquarium\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eIron Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI721\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 ppm ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 525 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter three minutes of non-use and two minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI721 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, iron reagent starter kit for 6 tests (6 powder reagent packets), battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI721\" target=\"_blank\" rel=\"noopener\"\u003eIron Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI721\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871391351153,"sku":"HI721","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi721-checkerhc-front.jpg?v=1792646344"}],"url":"https:\/\/hannainst.in\/collections\/industry-research.oembed","provider":"hanna","version":"1.0","type":"link"}