{"title":"Accessories – ISE Meters","description":"","products":[{"product_id":"stainless-steel-temperature-probe-hi7662-t","title":"Stainless Steel Temperature Probe - HI7662-T","description":"\u003cp\u003eHI7662-T is a stainless steel temperature probe that can be used for Hanna's benchtop meters and potentiometric titration systems.\u003c\/p\u003e\n\u003cp\u003eHigh accuracy thermometers provide the versatility,  speed,  and reliability required by users in all areas concerning temperature measurement. Speed is important when the reactions being monitored have the potential to change rapidly,  which can happen during titrations,  or standard or sample additions.\u003c\/p\u003e\n\u003cp\u003epH readings must be temperature compensated in order to obtain accurate results. The source of temperature measurement can be from the HI7662-T Temperature Sensor or from a trimmer that is manually adjusted. In either case,  the instrument is adjusting the pH reading to compensate for changes in the pH sensor. Temperature compensation provides the actual pH of the buffer or sample at the temperature of measurement.\u003c\/p\u003e\n\u003cp\u003eTemperature compensation can be obtained in three ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eA separate probe specifically for measuring temperature\u003c\/li\u003e\n\u003cli\u003eA probe with a temperature sensor built-in\u003c\/li\u003e\n\u003cli\u003eManual adjustment for temperature\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7662-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7662-T Stainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e - 5.0 to 105.0°C, 23.0 to 221.0°F, 268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C, 0.1 °F, 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1°C, ±0.4°F, ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor Type\u003c\/td\u003e\n\u003ctd\u003e NTC thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e AISI 316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 1 m (3.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e For use with Hanna benchtop meters and potentiometric titration systems with a phono connector input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7662-T\"\u003eHI7662-T Stainless Steel Temperature Probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871193792881,"sku":"HI7662-T","price":9600.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7662-tw_temperature-probe-2100x2100-f2e73f65-ddfd-45f4-b7ac-f9f3c97a8796.jpg?v=1792645857"},{"product_id":"liquid-membrane-ise-sensor-handle-hi4000-50","title":"Liquid Membrane ISE Sensor Handle - HI4000-50","description":"\u003cp\u003eThe HI4000-50 replacement sensor handle is compatible with Hanna's liquid ISE modules. The sensor handle can be used as a sensing half-cell with the calcium,  nitrate,  or potassium half-cell modules. The HI5315 reference half-cell electrode is required for use with the HI4000-50 sensing half-cell to complete the electrical circuit and to provide a stable reference voltage.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eReplaceable Liquid Modules\u003c\/strong\u003e - The calcium,  nitrate,  and potassium half-cell modules can easily be replaced on the sensor handle. The HI4000-50 acts as the sensing electrode in an ISE measurement system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body is composed of durable epoxy material.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4000-50 has a universal BNC connector for easy connection to any meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch4\u003eTheory of Operation\u003c\/h4\u003e\n\u003cp\u003eA liquid membrane ion selective electrode develops a voltage due to the ion exchange that occurs between the solution and the polymer membrane that contains organic ion exchange resin. When the ionic strength of the solution is fixed by the addition of ISA,  the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Liquid Membrane ISE Sensor Handle - HI4000-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e epoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-50\"\u003eLiquid Membrane ISE Sensor Handle - HI4000-50\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276564849,"sku":"HI4000-50","price":38702.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-50_2.jpg?v=1792646029"},{"product_id":"replacement-ph-assembly-for-ammonia-ise-hi4000-51","title":"Replacement pH Assembly for Ammonia ISE - HI4000-51","description":"\u003cp\u003eThe HI4000-51 replacement pH reference assembly is for use with Hanna's HI4101 ammonia gas sensing ion selective electrode (ISE). This internal glass pH assembly provides the sensing and reference components for the ammonia combination ISE.\u003c\/p\u003e\n\u003ch4\u003eTheory of Operation\u003c\/h4\u003e\n\u003cp\u003eA gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film of electrolyte are the same. The pH change is proportional to the concentration of dissolved gas in the sample solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4000-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eReplacement pH Assembly for Ammonia ISE - HI4000-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4000-51\" target=\"_blank\" rel=\"noopener\"\u003eReplacement pH Assembly for Ammonia ISE - HI4000-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276597617,"sku":"HI4000-51","price":49080.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-51.jpg?v=1792646029"},{"product_id":"replacement-membrane-cap-for-ammonia-ise-hi4000-52","title":"Replacement Membrane Cap for Ammonia ISE - HI4000-52","description":"\u003cp\u003eThe HI4000-52 replacement membrane cap is for use with Hanna's HI4101 ammonia gas sensing ion selective electrode (ISE). This durable Delrin® cap easily screws onto the outer body of the ISE when the gas-sensing membrane needs replacement.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Replacement Membrane Cap for Ammonia ISE - HI4000-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 1 cap\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-52\"\u003eReplacement Membrane Cap for Ammonia ISE - HI4000-52\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278662001,"sku":"HI4000-52","price":5021.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-52.jpg?v=1792646039"},{"product_id":"replacement-ph-assembly-for-carbon-dioxide-ise-hi4000-54","title":"Replacement pH Assembly for Carbon Dioxide ISE - HI4000-54","description":"\u003cp\u003eThe HI4000-54 replacement pH reference assembly is for use with Hanna's HI4105 carbon dioxide gas sensing ion selective electrode (ISE). This internal glass pH assembly provides the sensing and reference components for the carbon dioxide combination ISE.\u003c\/p\u003e\n\u003ch4\u003eTheory of Operation\u003c\/h4\u003e\n\u003cp\u003eA gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film of electrolyte are the same. The pH change is proportional to the concentration of dissolved gas in the sample solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Replacement pH Assembly for Carbon Dioxide ISE - HI4000-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-54\"\u003eReplacement pH Assembly for Carbon Dioxide ISE - HI4000-54\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278694769,"sku":"HI4000-54","price":49080.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-54.jpg?v=1792646040"},{"product_id":"halide-polishing-strips-24-pcs-hi4000-70","title":"Halide Polishing Strips (24 pcs) - HI4000-70","description":"\u003cp\u003eThe HI4000-70 is a pack of 24 halide polishing strips. A scratched,  pitted,  or oxidized sensing surface can be restored with HI4000-70 polishing strip. The user simply needs a small portion of the micro abrasive strip to polish a solid state membrane. By wetting the frosted side with purified water,  the polishing strip gently reconditions the sensing surface. A worn pellet surface can cause drift,  decreased sensitivity at low concentration levels,  or poor repeatability between measurements. Optimum ISE response can be restored by removing the damaged surface with the HI4000-70 polishing strips.\u003c\/p\u003e\n\u003cp\u003eHI4000-70 is made for use on the following ion selective electrodes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI4002 \/ HI4102 Bromide ISE\u003c\/li\u003e\n\u003cli\u003eHI4003 \/ HI4103 Cadmium ISE\u003c\/li\u003e\n\u003cli\u003eHI4007 \/ HI4107 Chloride ISE\u003c\/li\u003e\n\u003cli\u003eHI4008 \/ HI4108 Cupric ISE\u003c\/li\u003e\n\u003cli\u003eHI4009 \/ HI4109 Cyanide ISE\u003c\/li\u003e\n\u003cli\u003eHI4011 \/ HI4111 Iodide ISE\u003c\/li\u003e\n\u003cli\u003eHI4012 \/ HI4112 Lead\/Sulfate ISE\u003c\/li\u003e\n\u003cli\u003eHI4015 \/ HI4115 Silver\/Sulfide ISE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Halide Polishing Strips (24 pcs) - HI4000-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 24 strips\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-70\"\u003eHalide Polishing Strips (24 pcs) - HI4000-70\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280857457,"sku":"HI4000-70","price":4450.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-70.jpg?v=1792646041"},{"product_id":"ammonia-ise-membrane-kit-20-pcs-hi4001-51","title":"Ammonia ISE Membrane Kit (20 pcs) - HI4001-51","description":"\u003cp\u003eThe HI4001-51 replacement membrane kit contains 20 loose PTFE membranes for the ammonia gas sensing ISE. When the ammonia ISE is first being assembled,  or after a membrane is worn,  the HI4001-51 membrane kit allows for easy assemblage or replacement. With the help of HI740159 plastic tweezers and a pair of laboratory gloves,  the PTFE membrane is ensured to remain dry and undamaged for more reliable,  accurate measurements. The loose PTFE membrane is placed on the outer probe body and pulled taut once the membrane cap is screwed on.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE Membrane Kit (20 pcs) - HI4001-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 20 membranes\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-51\"\u003eAmmonia ISE Membrane Kit (20 pcs) - HI4001-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280890225,"sku":"HI4001-51","price":14605.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-51.jpg?v=1792646041"},{"product_id":"calcium-module-for-half-cell-ise-hi4004-51","title":"Calcium Module for Half-Cell ISE - HI4004-51","description":"\u003cp\u003eThe HI4004-51 calcium module is for use with the HI4004 calcium half-cell ion selective electrode (ISE). The liquid membrane sensor contains an organic polymer within the inert PVC matrix that is responsible for exchange of calcium ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the calcium ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4004-51 calcium half-cell module easily screws onto the HI4004 probe body,  allowing for quick assemblage or replacement. Presoaking the calcium sensor in HI4004-45 conditioning solution or a calcium standard (0.01M) without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4004-51 calcium module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Calcium Module for Half-Cell ISE - HI4004-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-51\"\u003eCalcium Module for Half-Cell ISE - HI4004-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281316209,"sku":"HI4004-51","price":28747.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-51_1.jpg?v=1792646048"},{"product_id":"carbon-dioxide-ise-membrane-kit-3-pcs-hi4005-53","title":"Carbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53","description":"\u003cp\u003eThe HI4005-53 replacement membrane kit contains 3 membrane caps with pre-formed PTFE membranes for the carbon dioxide gas sensing ISE. When the carbon dioxide ISE is first being assembled,  or after a membrane is worn,  the HI4005-53 membrane kit allows for easy assemblage or replacement. By simply screwing on the pre-assembled cap and membrane,  the sensitive PTFE membrane is ensured to remain dry and undamaged for more reliable,  accurate measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 3 membranes\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-53\"\u003eCarbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283446129,"sku":"HI4005-53","price":15594.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-53.jpg?v=1792646051"},{"product_id":"nitrate-module-for-half-cell-ise-3-pcs-hi4013-53","title":"Nitrate Module for Half-Cell ISE (3 pcs) - HI4013-53","description":"\u003cp\u003eThe HI4013-53 nitrate module is for use with the HI4013 nitrate half-cell ion selective electrode (ISE). The liquid membrane sensor contains an organic polymer within the inert PVC matrix that is responsible for exchange of nitrate ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the nitrate ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4013-53 nitrate half-cell module easily screws onto the HI4013 probe body,  allowing for quick assemblage or replacement. Presoaking the nitrate sensor in a dilute standard without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4013-53 nitrate module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate Module for Half-Cell ISE (3 pcs) - HI4013-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 3 modules\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-53\"\u003eNitrate Module for Half-Cell ISE (3 pcs) - HI4013-53\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285248369,"sku":"HI4013-53","price":35138.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-53.jpg?v=1792646057"},{"product_id":"hi4013-51-nitrate-module-for-half-cell-ise-1-pc","title":"HI4013-51 Nitrate Module for Half-Cell ISE (1 pc.)","description":"\u003cp\u003eThe HI4013-51 nitrate module is for use with the HI4013 nitrate half-cell ion-selective electrode (ISE). The liquid membrane sensor contains an organic polymer within the inert PVC matrix that is responsible for the exchange of nitrate ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the nitrate ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4013-51 nitrate half-cell module easily screws onto the HI4013 probe body,  allowing for quick assemblage or replacement. Presoaking the nitrate sensor in a dilute standard without ionic strength adjuster (ISA) for at least one-half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4013-53 nitrate module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI4013-51 Nitrate Module for Half-Cell ISE (1 pc.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-51\"\u003eHI4013-51 Nitrate Module for Half-Cell ISE (1 pc.)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871288033649,"sku":"HI4013-51","price":27444.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-51-1200x1200-a8a29fc2-c121-4aed-b8b6-f97072dcd2d9.jpg?v=1792646072"},{"product_id":"potassium-module-for-half-cell-ise-hi4014-51","title":"Potassium Module for Half-Cell ISE - HI4014-51","description":"\u003cp\u003eThe HI4014-51 potassium module is for use with the HI4014 potassium half-cell ion selective electrode (ISE). The liquid membrane sensor is comprised of a valinomycin-containing polymer within an inert PVC matrix. The sensor is responsible for the exchange of potassium ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the potassium ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4014-51 potassium half-cell module easily screws onto the HI4014 probe body,  allowing for quick assemblage or replacement. Presoaking the potassium sensor in a dilute standard without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4014-51 potassium module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4014-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Potassium Module for Half-Cell ISE - HI4014-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 1 module\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4014-51\"\u003ePotassium Module for Half-Cell ISE - HI4014-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290720625,"sku":"HI4014-51","price":28747.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4014-51_1.jpg?v=1792646082"},{"product_id":"calcium-module-for-combination-ise-hi4104-51","title":"Calcium Module for Combination ISE - HI4104-51","description":"\u003cp\u003eThe HI4104-51 calcium module is for use with the HI4104 calcium combination ion selective electrode (ISE). The liquid membrane sensor contains an organic polymer within the inert PVC matrix that is responsible for exchange of calcium ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the calcium ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4104-51 calcium combination module easily screws onto the HI4104 probe body,  allowing for quick assemblage or replacement. Pre-soaking the calcium sensor in HI4004-45 conditioning solution or a calcium standard (0.01M) without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4104-51 calcium module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4104-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Calcium Module for Combination ISE - HI4104-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 1 module\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4104-51\"\u003eCalcium Module for Combination ISE - HI4104-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871293604209,"sku":"HI4104-51","price":32064.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4104-51.jpg?v=1792646086"},{"product_id":"fluoride-module-for-combination-ise-hi4110-51","title":"Fluoride Module for Combination ISE  - HI4110-51","description":"\u003cp\u003eThe HI4110-51 fluoride module is for use with the HI4110 fluoride combination ion selective electrode (ISE). The module is a lanthanum fluoride (LaF\u003csub\u003e3\u003c\/sub\u003e) crystal membrane that contains openings within its lattice structure that allow fluoride ion exchange between the sample and internal solution. A charge imbalance develops between the sample and the internal cell in response to the fluoride ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4110-51 fluoride combination module easily screws onto the HI4110 probe body,  allowing for quick assemblage or replacement. Hanna recommends pre-soaking the fluoride sensor in a standard near expected concentrations before calibration. Conditioning in this way will activate the sensing crystal and help optimize the sensor response. Gently shaking the sensor down before measurement will place the internal solution next to the sensing membrane,  ensuring reliable,  accurate measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4110-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Fluoride Module for Combination ISE  - HI4110-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 1 module\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4110-51\"\u003eFluoride Module for Combination ISE - HI4110-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871293800817,"sku":"HI4110-51","price":32064.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4110-51.jpg?v=1792646089"},{"product_id":"nitrate-module-for-combination-ise-3-pcs-hi4113-53","title":"Nitrate Module for Combination ISE (3 pcs) - HI4113-53","description":"\u003cp\u003eThe HI4113-53 nitrate module is for use with the HI4113 nitrate combination ion selective electrode (ISE). The liquid membrane sensor contains an organic polymer within the inert PVC matrix that is responsible for exchange of nitrate ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the nitrate ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4113-53 nitrate combination module easily screws onto the HI4113 probe body,  allowing for quick assemblage or replacement. Presoaking the nitrate sensor in a dilute standard without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4113-53 nitrate module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4113-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate Module for Combination ISE (3 pcs) - HI4113-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 3 modules\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4113-53\"\u003eNitrate Module for Combination ISE (3 pcs) - HI4113-53\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871293899121,"sku":"HI4113-53","price":35138.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4113-53_1.png?v=1792646091"},{"product_id":"potassium-module-for-combination-ise-hi4114-51","title":"Potassium Module for Combination ISE - HI4114-51","description":"\u003cp\u003eThe HI4114-51 potassium module is for use with the HI4114 potassium combination ion selective electrode (ISE). The liquid membrane sensor is comprised of a valinomycin-containing polymer within an inert PVC matrix. The sensor is responsible for the exchange of potassium ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the potassium ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4114-51 potassium combination module easily screws onto the HI4114 probe body,  allowing for quick assemblage or replacement. Presoaking the potassium sensor in a dilute standard without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4114-51 potassium module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4114-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Potassium Module for Combination ISE - HI4114-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 1 module\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4114-51\"\u003ePotassium Module for Combination ISE - HI4114-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871296127345,"sku":"HI4114-51","price":32064.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4114-51.jpg?v=1792646091"},{"product_id":"electrode-refilling-pipettes-20-pcs-hi740157p","title":"Electrode Refilling Pipettes (20 pcs.) - HI740157P","description":"\u003cp\u003eThe HI740157P electrode refilling pipettes allow for safe,  convenient,  and precise transfer of electrolyte fill solution into refillable Hanna electrodes. The plastic,  unified design of the pipettes is convenient for quickly refilling or topping off electrolyte solution,  ensuring there is adequate head pressure for measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740157P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Electrode Refilling Pipettes (20 pcs.) - HI740157P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Quantity: 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740157P\"\u003eElectrode Refilling Pipettes (20 pcs.) - HI740157P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871395774833,"sku":"HI740157P","price":1833.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi704157p.jpg?v=1792646387"},{"product_id":"plastic-tweezers-hi740159","title":"Plastic Tweezers - HI740159","description":"\u003cp\u003eWith the help of HI740159 plastic tweezers,  the PTFE membranes of the ammonia and carbon dioxide gas sensing ISEs are ensured to remain dry and undamaged for more reliable,  accurate measurements. The loose PTFE membrane is placed on the outer probe body and pulled taut once the membrane cap is screwed on.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Plastic Tweezers - HI740159\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740159\"\u003ePlastic Tweezers - HI740159\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871395807601,"sku":"HI740159","price":1715.0,"currency_code":"INR","in_stock":true}]},{"product_id":"stainless-steel-temperature-probe-hi7662","title":"Stainless Steel Temperature Probe - HI7662","description":"\u003cp\u003eHI7662 is a stainless steel temperature probe that can be used for compatible Hanna meters.\u003c\/p\u003e\n\u003cp\u003eHigh accuracy thermometers provide the versatility,  speed,  and reliability required by users in all areas concerning temperature measurement. Speed is important when the reactions being monitored have the potential to change rapidly.\u003c\/p\u003e\n\u003cp\u003epH readings must be temperature compensated in order to obtain accurate results. The source of temperature measurement can be from the HI7662 Temperature Sensor or from a trimmer that is manually adjusted. In either case,  the instrument is adjusting the pH reading to compensate for changes in the pH sensor. Temperature compensation provides the actual pH of the buffer or sample at the temperature of measurement.\u003c\/p\u003e\n\u003ch4\u003eTemperature compensation can be obtained in three ways:\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eA separate probe specifically for measuring temperature\u003c\/li\u003e\n\u003cli\u003eA probe with a temperature sensor built-in\u003c\/li\u003e\n\u003cli\u003eManual adjustment for temperature\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Stainless Steel Temperature Probe - HI7662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7662\"\u003eStainless Steel Temperature Probe - HI7662\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871409308017,"sku":"HI7662","price":9924.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7662.jpg?v=1792646491"}],"url":"https:\/\/hannainst.in\/collections\/ise-meters-accessories.oembed","provider":"hanna","version":"1.0","type":"link"}