{"title":"Solutions – ISE Solutions","description":"","products":[{"product_id":"ionic-strength-adjuster-isa-for-halide-ises-hi4000-00","title":"Ionic Strength Adjuster (ISA) for Halide ISEs - HI4000-00","description":"\u003cp\u003eHI4000-00 is an ionic strength adjuster (ISA) solution for use with bromide,  cadmium,  chloride,  cupric,  iodide,  and silver\/sulfide ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Halide ISEs - HI4000-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-00\"\u003eIonic Strength Adjuster (ISA) for Halide ISEs - HI4000-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276466545,"sku":"HI4000-00","price":9924.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-00.jpg?v=1792646027"},{"product_id":"ise-slope-check-buffers-with-chloride-background-hi4000-47","title":"ISE Slope Check Buffers with Chloride Background - HI4000-47","description":"\u003cp\u003eHI4000-47 is a package containing pH 4 and pH 7 buffer packets with chloride ions and two plastic beakers. The special pH 4 and pH 7 buffers have a chloride background to verify the inner pH glass assembly housed within the ammonia and carbon dioxide gas sensing ISEs.\u003c\/p\u003e\n\u003cp\u003eBefore assembling an ammonia or carbon dioxide ISE for the first time,  or if reactivating after storage,  the inner glass assembly should be conditioned and tested as a pH electrode. The pH buffer packets can be added to 50 mL of deionized or distilled water and the sensor assembly carefully immersed in solution. When the mV measurement in each buffer solution is stable and recorded,  the mV difference can be calculated. A calculated mV difference equal or greater than 160 mV is acceptable for temperatures between 20 and 25℃.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e ISE Slope Check Buffers with Chloride Background - HI4000-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e packets and beakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 10 packets each buffer; 2 beakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-47\"\u003eISE Slope Check Buffers with Chloride Background - HI4000-47\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276499313,"sku":"HI4000-47","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-47.jpg?v=1792646027"},{"product_id":"ammonia-ise-filling-solution-hi4001-40","title":"Ammonia ISE Filling Solution - HI4001-40","description":"\u003cp\u003eThe HI4001-40 fill solution is a chloride ion-containing electrolyte that is required to provide a reference potential for the HI4101 ammonia gas sensing ion selective electrode (ISE). As ammonia diffuses through the gas permeable membrane,  the thin film of electrolyte on the surface of the pH sensing glass undergoes a pH change. The change in pH of the filling solution is proportional to the concentration of ammonia gas in the solution. The HI4001-40 is four bottles of 30 mL ammonia filling solution that ensure optimum measurement performance from the HI4101 ammonia ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE Filling Solution - HI4001-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-40\"\u003eAmmonia ISE Filling Solution - HI4001-40\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278399857,"sku":"HI4001-40","price":15692.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-40_2.jpg?v=1792646035"},{"product_id":"ammonia-ise-100-ppm-standard-hi4001-02","title":"Ammonia ISE 100 ppm Standard - HI4001-02","description":"\u003cp\u003eHI4001-02 is a 100 mg\/L (ppm) standard solution of ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N) used to calibrate the ammonia gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE 100 ppm Standard - HI4001-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 mg\/L (ppm) ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-02\"\u003eAmmonia ISE 100 ppm Standard - HI4001-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278432625,"sku":"HI4001-02","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-02-1200by1200-rgb.jpg?v=1792646036"},{"product_id":"ammonia-ise-1000-ppm-standard-hi4001-03","title":"Ammonia ISE 1000 ppm Standard - HI4001-03","description":"\u003cp\u003eHI4001-03 is a 1000 mg\/L (ppm) standard solution of ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N) used to calibrate the ammonia gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE 1000 ppm Standard - HI4001-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1000 mg\/L (ppm) ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-03\"\u003eAmmonia ISE 1000 ppm Standard - HI4001-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278498161,"sku":"HI4001-03","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-03.jpg?v=1792646037"},{"product_id":"ionic-strength-adjuster-isa-for-ammonia-and-cyanide-ises-hi4001-00","title":"Ionic Strength Adjuster (ISA) for Ammonia and Cyanide ISEs - HI4001-00","description":"\u003cp\u003eHI4001-00 is an alkaline ionic strength adjuster (ISA) solution for use with ammonia and cyanide ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Ammonia and Cyanide ISEs - HI4001-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-00\"\u003eIonic Strength Adjuster (ISA) for Ammonia and Cyanide ISEs - HI4001-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278530929,"sku":"HI4001-00","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-00.jpg?v=1792646037"},{"product_id":"ammonia-ise-conditioning-and-storage-solution-hi4001-45","title":"Ammonia ISE Conditioning and Storage Solution - HI4001-45","description":"\u003cp\u003eThe HI4001-45 solution is for the conditioning and storage for the HI4101 ammonia gas sensing ion selective electrode (ISE). Measurement of ammonia in solutions is determined by a pH change of the internal thin film of electrolyte. This conditioning and storage solution is necessary to keep the glass pH sensing element hydrated in order to accurately determine ammonia concentrations. The HI4001-45 is a 500 mL bottle of conditioning and storage solution that ensures optimum measurement performance from the HI4101 ammonia ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE Conditioning and Storage Solution - HI4001-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-45\"\u003eAmmonia ISE Conditioning and Storage Solution - HI4001-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278596465,"sku":"HI4001-45","price":8101.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-45.jpg?v=1792646038"},{"product_id":"ammonia-ise-0-1m-standard-hi4001-01","title":"Ammonia ISE 0.1M Standard - HI4001-01","description":"\u003cp\u003eHI4001-01 is a 0.1M standard solution of ammonia used to calibrate the ammonia gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE 0.1M Standard - HI4001-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M ammonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-01\"\u003eAmmonia ISE 0.1M Standard - HI4001-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278629233,"sku":"HI4001-01","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-01-1200by1200-rgb.jpg?v=1792646039"},{"product_id":"bromide-ise-0-1m-standard-hi4002-01","title":"Bromide ISE 0.1M Standard - HI4002-01","description":"\u003cp\u003eHI4002-01 is a 0.1M standard bromide solution used to calibrate the bromide solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Bromide ISE 0.1M Standard - HI4002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M bromide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4002-01\"\u003eBromide ISE 0.1M Standard - HI4002-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280955761,"sku":"HI4002-01","price":11531.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4002-01.jpg?v=1792646043"},{"product_id":"cadmium-ise-0-1m-standard-hi4003-01","title":"Cadmium ISE 0.1M Standard - HI4003-01","description":"\u003cp\u003eHI4003-01 is a 0.1M standard cadmium solution used to calibrate the cadmium solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4003-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCadmium ISE 0.1M Standard - HI4003-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M cadmium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4003-01\" target=\"_blank\" rel=\"noopener\"\u003eCadmium ISE 0.1M Standard - HI4003-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281054065,"sku":"HI4003-01","price":11531.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4003-01.jpg?v=1792646044"},{"product_id":"ionic-strength-adjuster-isa-for-calcium-ises-hi4004-00","title":"Ionic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00","description":"\u003cp\u003eHI4004-00 is an ionic strength adjuster (ISA) solution for use with calcium ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-00\"\u003eIonic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281152369,"sku":"HI4004-00","price":12010.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-00.jpg?v=1792646046"},{"product_id":"calcium-ise-0-1m-standard-hi4004-01","title":"Calcium ISE 0.1M Standard - HI4004-01","description":"\u003cp\u003eHI4004-01 is a 0.1M standard calcium solution used to calibrate the calcium liquid membrane ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4004-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCalcium ISE 0.1M Standard - HI4004-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M calcium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4004-01\" target=\"_blank\" rel=\"noopener\"\u003eCalcium ISE 0.1M Standard - HI4004-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281185137,"sku":"HI4004-01","price":11191.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-01.jpg?v=1792646046"},{"product_id":"calcium-ise-conditioning-and-storage-solution-hi4004-45","title":"Calcium ISE Conditioning and Storage Solution - HI4004-45","description":"\u003cp\u003eThe HI4004-45 solution is for the conditioning and storage for the HI4004 and HI4104 calcium liquid membrane ion selective electrodes (ISEs). Measurement of calcium in solutions is determined by calcium ion exchange through the organic polymer membrane. The membrane of the half-cell or combination calcium ISE should be presoaked in HI4004-45 solution for at least one half-hour before calibration to optimize the sensor response. The HI4004-45 is a 500 mL bottle of conditioning and storage solution that ensures optimum measurement performance from the HI4004 and HI4104 calcium ISEs.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Calcium ISE Conditioning and Storage Solution - HI4004-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-45\"\u003eCalcium ISE Conditioning and Storage Solution - HI4004-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281250673,"sku":"HI4004-45","price":10228.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-45.jpg?v=1792646047"},{"product_id":"ionic-strength-adjuster-isa-for-carbon-dioxide-ises-hi4005-00","title":"Ionic Strength Adjuster (ISA) for Carbon Dioxide ISEs - HI4005-00","description":"\u003cp\u003eHI4005-00 is an ionic strength adjuster (ISA) solution for use with carbon dioxide ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Carbon Dioxide ISEs - HI4005-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-00\"\u003eIonic Strength Adjuster (ISA) for Carbon Dioxide ISEs - HI4005-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281283441,"sku":"HI4005-00","price":10939.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-00.jpg?v=1792646048"},{"product_id":"carbon-dioxide-ise-0-1m-standard-hi4005-01","title":"Carbon Dioxide ISE 0.1M Standard - HI4005-01","description":"\u003cp\u003eHI4005-01 is a 0.1M standard carbon dioxide solution used to calibrate the carbon dioxide gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE 0.1M Standard - HI4005-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M carbon dioxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-01\"\u003eCarbon Dioxide ISE 0.1M Standard - HI4005-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283282289,"sku":"HI4005-01","price":11783.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-01.jpg?v=1792646049"},{"product_id":"carbon-dioxide-ise-1000-ppm-standard-hi4005-03","title":"Carbon Dioxide ISE 1000 ppm Standard - HI4005-03","description":"\u003cp\u003eHI4005-03 is a 1000 ppm (mg\/L) standard solution of carbon dioxide (as CaCO\u003csub\u003e3\u003c\/sub\u003e) used to calibrate the carbon dioxide gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE 1000 ppm Standard - HI4005-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1000 mg\/L (ppm) carbon dioxide (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-03\"\u003eCarbon Dioxide ISE 1000 ppm Standard - HI4005-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283347825,"sku":"HI4005-03","price":11783.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-03.jpg?v=1792646050"},{"product_id":"carbon-dioxide-ise-filling-solution-hi4005-40","title":"Carbon Dioxide ISE Filling Solution - HI4005-40","description":"\u003cp\u003eThe HI4005-40 fill solution is a chloride ion-containing electrolyte that is required to provide a reference potential for the HI4105 carbon dioxide gas sensing ion selective electrode (ISE). As carbon dioxide diffuses through the gas permeable membrane,  the thin film of electrolyte on the surface of the pH sensing glass undergoes a pH change. The change in pH of the filling solution is proportional to the concentration of carbon dioxide gas in the solution. The HI4005-40 is four bottles of 30 mL carbon dioxide filling solution that ensure optimum measurement performance from the HI4105 carbon dioxide ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE Filling Solution - HI4005-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-40\"\u003eCarbon Dioxide ISE Filling Solution - HI4005-40\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283380593,"sku":"HI4005-40","price":13910.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-40.jpg?v=1792646050"},{"product_id":"carbon-dioxide-ise-conditioning-and-storage-solution-hi4005-45","title":"Carbon Dioxide ISE Conditioning and Storage Solution - HI4005-45","description":"\u003cp\u003eThe HI4005-45 solution is for the conditioning and storage for the HI4105 carbon dioxide gas sensing ion selective electrode (ISE). Measurement of carbon dioxide in solutions is determined by a pH change of the internal thin film of electrolyte. This conditioning and storage solution is necessary to keep the glass pH sensing element hydrated in order to accurately determine carbon dioxide concentrations. The HI4005-45 is a 500 mL bottle of conditioning and storage solution that ensures optimum measurement performance from the HI4105 carbon dioxide ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4005-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCarbon Dioxide ISE Conditioning and Storage Solution - HI4005-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4005-45\" target=\"_blank\" rel=\"noopener\"\u003eCarbon Dioxide ISE Conditioning and Storage Solution - HI4005-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283413361,"sku":"HI4005-45","price":8441.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-45.jpg?v=1792646051"},{"product_id":"chloride-ise-0-1m-standard-hi4007-01","title":"Chloride ISE 0.1M Standard - HI4007-01","description":"\u003cp\u003eHI4007-01 is a 0.1M standard chloride solution used to calibrate the chloride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4007-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Chloride ISE 0.1M Standard - HI4007-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M chloride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4007-01\"\u003eChloride ISE 0.1M Standard - HI4007-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283544433,"sku":"HI4007-01","price":7962.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4007-01.jpg?v=1792646053"},{"product_id":"chloride-ise-100-ppm-standard-hi4007-02","title":"Chloride ISE 100 ppm Standard - HI4007-02","description":"\u003cp\u003eHI4007-02 is a 100 ppm (mg\/L) standard solution of chloride used to calibrate the chloride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4007-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Chloride ISE 100 ppm Standard - HI4007-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 mg\/L (ppm) chloride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4007-02\"\u003eChloride ISE 100 ppm Standard - HI4007-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283577201,"sku":"HI4007-02","price":7962.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4007-02.jpg?v=1792646053"},{"product_id":"chloride-ise-1000-ppm-standard-hi4007-03","title":"Chloride ISE 1000 ppm Standard - HI4007-03","description":"\u003cp\u003eHI4007-03 is a 1000 ppm (mg\/L) standard solution of chloride used to calibrate the chloride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4007-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChloride ISE 1000 ppm Standard - HI4007-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e1000 mg\/L (ppm) chloride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4007-03\" target=\"_blank\" rel=\"noopener\"\u003eChloride ISE 1000 ppm Standard - HI4007-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283642737,"sku":"HI4007-03","price":7962.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4007-03_1l.jpg?v=1792646054"},{"product_id":"ionic-strength-adjuster-isa-for-nitrate-ises-hi4013-00","title":"Ionic Strength Adjuster (ISA) for Nitrate ISEs - HI4013-00","description":"\u003cp\u003eHI4013-00 is an ionic strength adjuster (ISA) solution for use with nitrate ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Nitrate ISEs - HI4013-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-00\"\u003eIonic Strength Adjuster (ISA) for Nitrate ISEs - HI4013-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283773809,"sku":"HI4013-00","price":10228.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-00.jpg?v=1792646056"},{"product_id":"nitrate-ise-0-1m-standard-hi4013-01","title":"Nitrate ISE 0.1M Standard - HI4013-01","description":"\u003cp\u003eHI4013-01 is a 0.1M standard nitrate solution used to calibrate the nitrate liquid membrane ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate ISE 0.1M Standard - HI4013-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-01\"\u003eNitrate ISE 0.1M Standard - HI4013-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285313905,"sku":"HI4013-01","price":9888.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-01.jpg?v=1792646058"},{"product_id":"nitrate-ise-100-ppm-standard-hi4013-02","title":"Nitrate ISE 100 ppm Standard - HI4013-02","description":"\u003cp\u003eHI4013-02 is a 100 ppm (mg\/L) standard solution of nitrate (as NO\u003csub\u003e3\u003c\/sub\u003e-N) used to calibrate the nitrate liquid membrane combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate ISE 100 ppm Standard - HI4013-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 mg\/L (ppm) nitrate (as NO\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-02\"\u003eNitrate ISE 100 ppm Standard - HI4013-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285346673,"sku":"HI4013-02","price":9888.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-02.jpg?v=1792646058"},{"product_id":"cupric-ise-0-1m-standard-hi4008-01","title":"Cupric ISE 0.1M Standard - HI4008-01","description":"\u003cp\u003eHI4008-01 is a 0.1M standard cupric solution used to calibrate the cupric solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4008-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCupric ISE 0.1M Standard - HI4008-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M cupric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4008-01\" target=\"_blank\" rel=\"noopener\"\u003eCupric ISE 0.1M Standard - HI4008-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285379441,"sku":"HI4008-01","price":13313.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4008-01.jpg?v=1792646059"},{"product_id":"tisab-ii-for-fluoride-ises-500-ml-hi4010-00","title":"TISAB II for Fluoride ISEs (500 mL) - HI4010-00","description":"\u003cp\u003eHI4010-00 TISAB II is an ionic strength adjuster solution for use with fluoride ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003cp\u003eTISAB II is formulated for water sample analysis to provide samples and standards alike with a constant ionic strength. The solution also adjusts the pH background of the solution and complexes with various metal ions,  such as aluminum and iron,  that form compounds with fluoride. The complexing ability of TISAB II ensures a total fluoride measurement can be determined.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TISAB II for Fluoride ISEs (500 mL) - HI4010-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-00\"\u003eTISAB II for Fluoride ISEs (500 mL) - HI4010-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285510513,"sku":"HI4010-00","price":6319.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-00.jpg?v=1792646062"},{"product_id":"fluoride-ise-0-1m-standard-0-1m-hi4010-01","title":"Fluoride ISE 0.1M Standard 0.1M - HI4010-01","description":"\u003cp\u003eHI4010-01 is a 0.1M standard fluoride solution used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4010-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFluoride ISE 0.1M Standard 0.1M - HI4010-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M fluoride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4010-01\" target=\"_blank\" rel=\"noopener\"\u003eFluoride ISE 0.1M Standard 0.1M - HI4010-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285543281,"sku":"HI4010-01","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-01.jpg?v=1792646062"},{"product_id":"fluoride-ise-100-ppm-standard-hi4010-02","title":"Fluoride ISE 100 ppm Standard - HI4010-02","description":"\u003cp\u003eHI4010-02 is a 100 ppm (mg\/L) standard solution of fluoride used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Fluoride ISE 100 ppm Standard - HI4010-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 mg\/L (ppm) fluoride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-02\"\u003eFluoride ISE 100 ppm Standard - HI4010-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285576049,"sku":"HI4010-02","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-02-1200by1200-rgb.jpg?v=1792646062"},{"product_id":"tisab-ii-for-fluoride-ises-1-gallon-hi4010-05","title":"TISAB II for Fluoride ISEs (1 gallon) - HI4010-05","description":"\u003cp\u003eHI4010-05 TISAB II is an ionic strength adjuster solution for use with fluoride ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003cp\u003eTISAB II is formulated for water sample analysis to provide samples and standards alike with a constant ionic strength. The solution also adjusts the pH background of the solution and complexes with various metal ions,  such as aluminum and iron,  that form compounds with fluoride. The complexing ability of TISAB II ensures a total fluoride measurement can be determined.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TISAB II for Fluoride ISEs (1 gallon) - HI4010-05\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 1 gallon (3.78 L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-05\"\u003eTISAB II for Fluoride ISEs (1 gallon) - HI4010-05\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285641585,"sku":"HI4010-05","price":15352.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-05-1200by1200-rgb.jpg?v=1792646064"},{"product_id":"fluoride-ise-1000-ppm-standard-hi4010-03","title":"Fluoride ISE 1000 ppm Standard - HI4010-03","description":"\u003cp\u003eHI4010-03 is a 1000 ppm (mg\/L) standard solution of fluoride used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Fluoride ISE 1000 ppm Standard - HI4010-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1000 mg\/L (ppm) fluoride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-03\"\u003eFluoride ISE 1000 ppm Standard - HI4010-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285674353,"sku":"HI4010-03","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-03-1200by1200-rgb.jpg?v=1792646064"},{"product_id":"tisab-iii-concentrate-for-fluoride-ises-hi4010-06","title":"TISAB III Concentrate for Fluoride ISEs - HI4010-06","description":"\u003cp\u003eHI4010-06 TISAB III is a more concentrated solution of ionic strength adjuster than TISAB II for use with fluoride ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003cp\u003eTISAB III is a concentrated ISA solution formulated for water sample analysis to provide samples and standards alike with a constant ionic strength. The solution also adjusts the pH background of the solution and complexes with various metal ions,  such as aluminum and iron,  that form compounds with fluoride. The complexing ability of TISAB III ensures a total fluoride measurement can be determined.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TISAB III Concentrate for Fluoride ISEs - HI4010-06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-06\"\u003eTISAB III Concentrate for Fluoride ISEs - HI4010-06\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285707121,"sku":"HI4010-06","price":10115.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-06.jpg?v=1792646064"},{"product_id":"fluoride-ise-10-ppm-standard-with-tisab-ii-hi4010-10","title":"Fluoride ISE 10 ppm Standard with TISAB II - HI4010-10","description":"\u003cp\u003eHI4010-10 is a 10 ppm (mg\/L) fluoride standard that is premixed with TISAB II. TISAB II is an ISA solution that is used to fix the activity of the fluoride ions in the solution so that a concentration measurement can be made. The TISAB II also reduces interferences from a low pH and from interfering ions that will complex with fluoride,  making it not detectable by the ISE.\u003c\/p\u003e\n\u003cp\u003eThis solution is used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility. ISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength.\u003c\/p\u003e\n\u003cp\u003eThe HI4010-10 standard comes premixed with TISAB II ionic strength adjuster,  so it is ready to use for calibration without any further addition of ISA. Samples that are measured following calibration with the HI4010-10 standard should have the appropriate volume of TISAB II or TISAB III added before measurement with the fluoride ISE.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eColor coded solution for easy standard identification\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEasy to identify which standard is being used for calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Fluoride ISE 10 ppm Standard with TISAB II - HI4010-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 10 ppm (mg\/L) fluoride with TISAB II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-10\"\u003eFluoride ISE 10 ppm Standard with TISAB II - HI4010-10\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287378289,"sku":"HI4010-10","price":9291.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-10_2.jpg?v=1792646065"},{"product_id":"fluoride-ise-1-ppm-standard-with-tisab-ii-hi4010-11","title":"Fluoride ISE 1 ppm Standard with TISAB II - HI4010-11","description":"\u003cp\u003eHI4010-11 is a 1 ppm (mg\/L) fluoride standard that is premixed with TISAB II. TISAB II is an ISA solution that is used to fix the activity of the fluoride ions in the solution so that a concentration measurement can be made. The TISAB II also reduces interferences from a low pH and from interfering ions that will complex with fluoride,  making it not detectable by the ISE.\u003c\/p\u003e\n\u003cp\u003eThis solution is used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility. ISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength.\u003c\/p\u003e\n\u003cp\u003eThe HI4010-11 standard comes premixed with TISAB II ionic strength adjuster,  so it is ready to use for calibration without any further addition of ISA. Samples that are measured following calibration with the HI4010-11 standard should have the appropriate volume of TISAB II or TISAB III added before measurement with the fluoride ISE.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eColor coded solution for easy standard identification\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEasy to identify which standard is being used for calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Fluoride ISE 1 ppm Standard with TISAB II - HI4010-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1 ppm (mg\/L) fluoride with TISAB II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-11\"\u003eFluoride ISE 1 ppm Standard with TISAB II - HI4010-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287443825,"sku":"HI4010-11","price":9291.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-11_2.jpg?v=1792646066"},{"product_id":"fluoride-ise-2-ppm-standard-with-tisab-ii-hi4010-12","title":"Fluoride ISE 2 ppm Standard with TISAB II - HI4010-12","description":"\u003cp\u003eHI4010-12 is a 2 ppm (mg\/L) fluoride standard that is premixed with TISAB II. TISAB II is an ISA solution that is used to fix the activity of the fluoride ions in the solution so that a concentration measurement can be made. The TISAB II also reduces interferences from a low pH and from interfering ions that will complex with fluoride,  making it not detectable by the ISE.\u003c\/p\u003e\n\u003cp\u003eThis solution is used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility. ISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration should be performed at a minimum of two points accuracy.\u003c\/p\u003e\n\u003cp\u003eThe HI4010-12 standard comes premixed with TISAB II (Total Ionic Strength Adjuster Buffer),  and is ready to use for calibration. It is important that if the calibration standard has TISAB II then the sample must also have TISAB II added in the same proportions. Users that calibrate with the HI4010-12 must add TISAB II to their sample. The ratio is 1:1 in which a 50 ml sample to be tested will require 50 ml of TISAB.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eColor coded solution for easy standard identification\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEasy to identify which standard is being used for calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Fluoride ISE 2 ppm Standard with TISAB II - HI4010-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 2 ppm (mg\/L) fluoride with TISAB II\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-12\"\u003eFluoride ISE 2 ppm Standard with TISAB II - HI4010-12\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287476593,"sku":"HI4010-12","price":9291.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-12.jpg?v=1792646066"},{"product_id":"iodide-ise-0-1m-standard-hi4011-01","title":"Iodide ISE 0.1M Standard - HI4011-01","description":"\u003cp\u003eHI4011-01 is a 0.1M standard iodide solution used to calibrate the iodide solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4011-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Iodide ISE 0.1M Standard - HI4011-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M iodide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4011-01\"\u003eIodide ISE 0.1M Standard - HI4011-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287607665,"sku":"HI4011-01","price":13086.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-40a.jpg?v=1792646068"},{"product_id":"fluoride-calibration-solution-kit-hi4010-30","title":"Fluoride Calibration Solution Kit - HI4010-30","description":"\u003cp\u003eHI4010-30 is a fluoride solution kit that contains four bottles each of the following:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI4010-11 fluoride standard (1 ppm) with TISAB II\u003c\/li\u003e\n\u003cli\u003eHI4010-10 fluoride standard (10 ppm) with TISAB II\u003c\/li\u003e\n\u003cli\u003eHI4010-00 TISAB II ionic strength adjuster\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe standards are used to calibrate the fluoride solid state ion selective electrode (ISE) while the TISAB II solution is added to samples to stabilize the ionic strength. The HI4010-11 and HI4010-10 standards come premixed with TISAB II ionic strength adjuster,  so they are ready to use for calibration without any further addition of ISA. Samples that are measured after calibrating with the HI4010-11 and HI4010-10 standards need to have the appropriate volume of HI4010-00 TISAB II added before taking any measurements with the fluoride ISE.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eColor coded solution for easy standard identification\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEasy to identify which standard is being used for calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4010-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Fluoride Calibration Solution Kit - HI4010-30\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI4010-30 kit includes HI4010-10 standard (4), HI4011-11 standard (4), and HI4010-00 ISA (4).\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4010-30\"\u003eFluoride Calibration Solution Kit - HI4010-30\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287640433,"sku":"HI4010-30","price":33310.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-30.jpg?v=1792646068"},{"product_id":"sulfate-ise-0-1m-standard-hi4012-21","title":"Sulfate ISE 0.1M Standard - HI4012-21","description":"\u003cp\u003eHI4012-21 is a 0.1M standard sulfate solution used for titration measurements with the lead\/sulfate solid state ion selective electrode (ISE). This solution is necessary to standardize lead perchlorate solutions for sulfate titrations. Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4012-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sulfate ISE 0.1M Standard - HI4012-21\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M sulfate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4012-21\"\u003eSulfate ISE 0.1M Standard - HI4012-21\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287738737,"sku":"HI4012-21","price":13086.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4012-21.jpg?v=1792646070"},{"product_id":"ionic-strength-adjuster-isa-for-lead-sulfate-ises-hi4012-00","title":"Ionic Strength Adjuster (ISA) for Lead\/Sulfate ISEs - HI4012-00","description":"\u003cp\u003eHI4012-00 is an ionic strength adjuster (ISA) solution for use with lead\/sulfate ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4012-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Lead\/Sulfate ISEs - HI4012-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4012-00\"\u003eIonic Strength Adjuster (ISA) for Lead\/Sulfate ISEs - HI4012-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287705969,"sku":"HI4012-00","price":10362.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4012-00_1.jpg?v=1792646070"},{"product_id":"nitrate-ise-1000-ppm-standard-hi4013-03","title":"Nitrate ISE 1000 ppm Standard - HI4013-03","description":"\u003cp\u003eHI4013-03 is a 1000 ppm (mg\/L) standard solution of nitrate (as NO\u003csub\u003e3\u003c\/sub\u003e-N) used to calibrate the nitrate liquid membrane combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate ISE 1000 ppm Standard - HI4013-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1000 mg\/L (ppm) nitrate (as NO\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-03\"\u003eNitrate ISE 1000 ppm Standard - HI4013-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287968113,"sku":"HI4013-03","price":9888.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-03.jpg?v=1792646072"},{"product_id":"interferent-suppressant-isa-isisa-for-nitrate-ises-hi4013-06","title":"Interferent Suppressant ISA (ISISA) for Nitrate ISEs - HI4013-06","description":"\u003cp\u003eHI4013-06 is a nitrate interferent suppressant ISA solution for use with nitrate ion selective electrodes (ISEs). When using the nitrate ISE to measure nitrate in samples such as drinking water and wastewater,  the HI4013-06 solution must be added to stabilize the ionic strength of the solution,  as well as to remove interfering ions,  including chloride.\u003c\/p\u003e\n\u003cp\u003eHanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Interferent Suppressant ISA (ISISA) for Nitrate ISEs - HI4013-06\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-06\"\u003eInterferent Suppressant ISA (ISISA) for Nitrate ISEs - HI4013-06\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871288000881,"sku":"HI4013-06","price":9888.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-06.jpg?v=1792646072"},{"product_id":"ionic-strength-adjuster-isa-for-potassium-ises-hi4014-00","title":"Ionic Strength Adjuster (ISA) for Potassium ISEs - HI4014-00","description":"\u003cp\u003eHI4014-00 is an ionic strength adjuster (ISA) solution for use with potassium ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4014-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Potassium ISEs - HI4014-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4014-00\"\u003eIonic Strength Adjuster (ISA) for Potassium ISEs - HI4014-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290261873,"sku":"HI4014-00","price":12494.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4014-00.jpg?v=1792646074"},{"product_id":"potassium-ise-0-1m-standard-hi4014-01","title":"Potassium ISE 0.1M Standard - HI4014-01","description":"\u003cp\u003eHI4014-01 is a 0.1M standard potassium solution used to calibrate the potassium liquid membrane ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4014-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Potassium ISE 0.1M Standard - HI4014-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M potassium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4014-01\"\u003ePotassium ISE 0.1M Standard - HI4014-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290327409,"sku":"HI4014-01","price":11191.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4014-01_1200.jpg?v=1792646074"},{"product_id":"sodium-ise-conditioning-solution-hi4016-46","title":"Sodium ISE Conditioning Solution - HI4016-46","description":"\u003cp\u003eThe HI4016-46 solution is for conditioning,  or etching,  the FC300B sodium ion selective electrode (ISE). Measurement of sodium in solutions is determined by ion exchange between the selectively permeable glass membrane and the sample solution. By conditioning the glass membrane,  a thin layer of glass is removed,  exposing a fresh surface in which sodium ion exchange can occur. After conditioning,  the electrode should be soaked in storage solution before calibration and measurement. The HI4016-46 is a 500 mL bottle of conditioning solution that ensures optimum measurement performance from the FC300B sodium ISE.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eNote\u003c\/strong\u003e: Use caution when handling HI4016-46 conditioning solution. Personal protective equipment should be worn.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4016-46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium ISE Conditioning Solution - HI4016-46\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4016-46\"\u003eSodium ISE Conditioning Solution - HI4016-46\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290425713,"sku":"HI4016-46","price":1277.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4016-46.jpg?v=1792646076"},{"product_id":"sodium-ise-storage-solution-hi4016-45","title":"Sodium ISE Storage Solution - HI4016-45","description":"\u003cp\u003eThe HI4016-45 solution is for storage of the FC300B sodium ion selective electrode (ISE). Measurement of sodium in solutions is determined by ion exchange between the selectively permeable glass membrane and the sample solution. The glass sensing membrane must remain hydrated in order to accurately determine sodium concentrations. This solution provides ideal conditions to rehydrate the membrane surface and prepare it for sodium measurements. The HI4016-45 is a 500 mL bottle of storage solution that ensures optimum measurement performance from the FC300B sodium ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4016-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium ISE Storage Solution - HI4016-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4016-45\"\u003eSodium ISE Storage Solution - HI4016-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290392945,"sku":"HI4016-45","price":4192.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4016-45-1200by1200-rgb.jpg?v=1792646076"},{"product_id":"sodium-ise-electrode-fill-solution-4-x-30-ml-hi7079","title":"Sodium ISE Electrode Fill Solution (4 x 30 mL) - HI7079","description":"\u003cp\u003eThe electrolyte level in refillable electrodes should be checked before performing any measurement. If the level is low,  refill with the proper electrolyte solution to ensure the correct electrode performance.\u003c\/p\u003e\n\u003cp\u003eThis simple maintenance helps guarantee adequate head pressure to promote efficiency and precision of your refillable electrodes.\u003c\/p\u003e\n\u003cp\u003eSome electrolyte solutions are also available in FDA compliant bottles.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium ISE Electrode Fill Solution (4 x 30 mL) - HI7079\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e electrolyte solution, 2 M NH4Cl + AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7079\"\u003eSodium ISE Electrode Fill Solution (4 x 30 mL) - HI7079\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290491249,"sku":"HI7079","price":5243.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/30ml_5.png?v=1792646078"},{"product_id":"sodium-ise-100-ppm-standard-hi4016-02","title":"Sodium ISE 100 ppm Standard - HI4016-02","description":"\u003cp\u003eHI4016-02 is a 100 ppm (mg\/L) standard sodium solution used to calibrate the sodium glass ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4016-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium ISE 100 ppm Standard - HI4016-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 ppm (mg\/L) sodium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4016-02\"\u003eSodium ISE 100 ppm Standard - HI4016-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290524017,"sku":"HI4016-02","price":9631.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4016-02-1200by1200-rgb.jpg?v=1792646078"},{"product_id":"sodium-ise-0-1m-standard-hi4016-01","title":"Sodium ISE 0.1M Standard - HI4016-01","description":"\u003cp\u003eHI4016-01 is a 0.1M standard sodium solution used to calibrate the sodium glass ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4016-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium ISE 0.1M Standard - HI4016-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M sodium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4016-01\"\u003eSodium ISE 0.1M Standard - HI4016-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290556785,"sku":"HI4016-01","price":9631.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4016-01.jpg?v=1792646078"},{"product_id":"sodium-ise-1000-ppm-standard-hi4016-03","title":"Sodium ISE 1000 ppm Standard - HI4016-03","description":"\u003cp\u003eHI4016-03 is a 1000 ppm (mg\/L) standard sodium solution used to calibrate the sodium glass ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4016-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium ISE 1000 ppm Standard - HI4016-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1000 ppm (mg\/L) sodium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4016-03\"\u003eSodium ISE 1000 ppm Standard - HI4016-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290622321,"sku":"HI4016-03","price":9631.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4016-03-1200by1200-rgb.jpg?v=1792646080"},{"product_id":"sodium-ise-10-ppm-standard-hi4016-10","title":"Sodium ISE 10 ppm Standard - HI4016-10","description":"\u003cp\u003eHI4016-10 is a 10 ppm (mg\/L) standard sodium solution used to calibrate the sodium glass ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4016-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium ISE 10 ppm Standard - HI4016-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 10 ppm (mg\/L) sodium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4016-10\"\u003eSodium ISE 10 ppm Standard - HI4016-10\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290655089,"sku":"HI4016-10","price":9631.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4016-10-1200by1200-rgb.jpg?v=1792646080"},{"product_id":"ionic-strength-adjuster-isa-for-sodium-ises-hi4016-00","title":"Ionic Strength Adjuster (ISA) for Sodium ISEs - HI4016-00","description":"\u003cp\u003eHI4016-00 is an ionic strength adjuster (ISA) solution for use with sodium ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4016-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Sodium ISEs - HI4016-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4016-00\"\u003eIonic Strength Adjuster (ISA) for Sodium ISEs - HI4016-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290687857,"sku":"HI4016-00","price":6865.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-00_1.jpg?v=1792646080"}],"url":"https:\/\/hannainst.in\/collections\/ise-solutions-solutions.oembed?page=2","provider":"hanna","version":"1.0","type":"link"}