{"title":"Accessories – Lab Supplies","description":"","products":[{"product_id":"stainless-steel-temperature-probe-hi7662-t","title":"Stainless Steel Temperature Probe - HI7662-T","description":"\u003cp\u003eHI7662-T is a stainless steel temperature probe that can be used for Hanna's benchtop meters and potentiometric titration systems.\u003c\/p\u003e\n\u003cp\u003eHigh accuracy thermometers provide the versatility,  speed,  and reliability required by users in all areas concerning temperature measurement. Speed is important when the reactions being monitored have the potential to change rapidly,  which can happen during titrations,  or standard or sample additions.\u003c\/p\u003e\n\u003cp\u003epH readings must be temperature compensated in order to obtain accurate results. The source of temperature measurement can be from the HI7662-T Temperature Sensor or from a trimmer that is manually adjusted. In either case,  the instrument is adjusting the pH reading to compensate for changes in the pH sensor. Temperature compensation provides the actual pH of the buffer or sample at the temperature of measurement.\u003c\/p\u003e\n\u003cp\u003eTemperature compensation can be obtained in three ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eA separate probe specifically for measuring temperature\u003c\/li\u003e\n\u003cli\u003eA probe with a temperature sensor built-in\u003c\/li\u003e\n\u003cli\u003eManual adjustment for temperature\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7662-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7662-T Stainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e - 5.0 to 105.0°C, 23.0 to 221.0°F, 268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C, 0.1 °F, 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1°C, ±0.4°F, ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor Type\u003c\/td\u003e\n\u003ctd\u003e NTC thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e AISI 316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 1 m (3.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e For use with Hanna benchtop meters and potentiometric titration systems with a phono connector input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7662-T\"\u003eHI7662-T Stainless Steel Temperature Probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871193792881,"sku":"HI7662-T","price":9600.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7662-tw_temperature-probe-2100x2100-f2e73f65-ddfd-45f4-b7ac-f9f3c97a8796.jpg?v=1792645857"},{"product_id":"plastic-beaker-set-100-ml-10-hi740036p","title":"Plastic Beaker Set,  100 mL (10) - HI740036P","description":"\u003cp\u003eThe HI740036P is a set of 10 replacement plastic beakers used with Hanna test kits and various meters. While Hanna offers rugged plastic beakers in several different sizes,  the HI740036P are the 100 mL graduated beaker version.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740036P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Plastic Beaker Set, 100 mL (10) - HI740036P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Size: 100 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740036P\"\u003ePlastic Beaker Set, 100 mL (10) - HI740036P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235113329,"sku":"HI740036P","price":2348.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740036p.jpg?v=1792645912"},{"product_id":"magnetic-stir-bars-10-hi731319","title":"Magnetic Stir Bars (10) - HI731319","description":"\u003cp\u003eThe HI731319 set of 10 magnetic stir bars made for a variety of applications. Used in a laboratory setting,  a magnetic stirrer together with magnetic stir bars continually stir buffers and\/or samples to keep them homogeneous. By keeping samples uniform during measurement and titration,  erroneous results are eliminated by preventing any temperature gradients or inadequate mixing when chemicals are added to a sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Magnetic Stir Bars (10) - HI731319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 25 mm x 7 mm \/ 1” x 0.3”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eQuantity: 10\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731319\"\u003eMagnetic Stir Bars (10) - HI731319\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235277169,"sku":"HI731319","price":8250.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731319.jpg?v=1792645914"},{"product_id":"power-adapter-115-vac-to-12-vdc-hi710005","title":"Power Adapter 115 VAC to 12 VDC - HI710005","description":"\u003cp\u003eHI710005 is a power adapter that will convert 115 VAC outlets to 12 VDC to enable use with Hanna meters. The adapter has two flat prongs for use in the United States.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI710005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Power Adapter 115 VAC to 12 VDC - HI710005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 50 x 62.5 x 40 mm \/ 2.0 x 2.5 x 1.6”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI710005\"\u003ePower Adapter 115 VAC to 12 VDC - HI710005\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235309937,"sku":"HI710005","price":2348.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi710005.jpg?v=1792645914"},{"product_id":"electrode-holder-with-steel-base-hi76405","title":"Electrode Holder with Steel Base - HI76405","description":"\u003cp\u003eThe HI76405 cantilever electrode stand features a large and sturdy steel base. The rectangular base provides a great level of strength and stability when adjusting the electrode arm. The electrode arm is able to hold up to three 12 mm diameter or less electrodes. When paired with a multichannel meter,  this feature allows simultaneous measurements of a single sample to be performed and viewed. For measurements that require temperature compensation,  a Hanna temperature probe can be placed in the electrode holder to obtain accurately compensated readings.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI76405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Electrode Holder with Steel Base - HI76405\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 12 in. x 6.5 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI76405\"\u003eElectrode Holder with Steel Base - HI76405\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235342705,"sku":"HI76405","price":13503.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi76405.jpg?v=1792645914"},{"product_id":"power-adapter-230-vac-to-12-vdc-hi710006","title":"Power Adapter 230 VAC to 12 VDC - HI710006","description":"\u003cp\u003eHI710005 is a power adapter that will convert 115 VAC outlets to 12 VDC to enable use with Hanna meters within the United States. The adapter has two round prongs for use in European countries.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI710006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Power Adapter 230 VAC to 12 VDC - HI710006\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 50 x 62.5 x 40 mm \/ 2.0 x 2.5 x 1.6”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI710006\"\u003ePower Adapter 230 VAC to 12 VDC - HI710006\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871388074353,"sku":"HI710006","price":2348.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/power-supply_720x600_f73fe03c-bd18-41f6-b412-3434dcf46f46.jpg?v=1792646321"},{"product_id":"magnetic-stir-bars-10-medium-sized-hi731320","title":"Magnetic Stir Bars (10) Medium Sized - HI731320","description":"\u003cp\u003eThe HI731320 set of 10 magnetic stir bars made for a variety of applications. Used in a laboratory setting,  a magnetic stirrer together with magnetic stir bars continually stir buffers and\/or samples to keep them homogeneous. By keeping samples uniform during measurement and titration,  erroneous results are eliminated by preventing any temperature gradients or inadequate mixing when chemicals are added to a sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Magnetic Stir Bars (10) Medium Sized - HI731320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e L 50 mm x dia 7 mm\/ 2 in. x 0.3 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eQuantity: 10\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731320\"\u003eMagnetic Stir Bars (10) Medium Sized - HI731320\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871393415537,"sku":"HI731320","price":10619.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731319_3.jpg?v=1792646363"},{"product_id":"glass-test-tube-with-caps-25-ml-2-pcs-hi740220","title":"Glass Test Tube with caps, 25 mL (2 pcs) - HI740220","description":"\u003cp\u003eHI740220 are two replacement 25 mL glass vials with caps for the HI83749 Portable Turbidity and Bentocheck Meter. When determining the amount of bentonite fining reagent to add to a wine,  four samples should be prepared in 25 mL glass vials. Each vial should contain a fixed amount of wine along with an increasing amount of bentonite suspension. After mixing and allowing to settle for 15 minutes,  each sample can be filtered and the turbidity can be determined.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Glass Cylinder Set (2 x 25 mL) - HI740220\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Package: glass 25 mL vial and caps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cbr\u003e\u003cbr\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740220\"\u003eGlass Cylinder Set (2 x 25 mL) - HI740220\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871393939825,"sku":"HI740220","price":2204.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740220.jpg?v=1792646369"},{"product_id":"graduated-pipette-2000-l-hi731342","title":"Graduated Pipette (2000 µL) - HI731342","description":"\u003cp\u003eThe HI731342 Graduated Pipette is able to accurately transfer 2000 µL volumes of liquid that need to be precisely dosed. The liquid is aspirated into disposable tips, eliminating cross contamination of samples.\u003c\/p\u003e\n\u003cp\u003eBy simply pressing the pushbutton to the first stop, immersing the disposable tip into the sample, and slowly releasing the pushbutton, an accurate volume of 2000 µL of liquid is taken up. To dispense the liquid, users can press the pushbutton past the first stop to the second stop to ensure the full volume is expelled. The built-in tip ejector provides a hassle-free way for users to discard their HI731352 Plastic Pipette Tips.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI731342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eGraduated Pipette (2000 µL) - HI731342\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI731342\" target=\"_blank\" rel=\"noopener\"\u003eGraduated Pipette (2000 µL) - HI731342\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871394038129,"sku":"HI731342","price":16969.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731342_1200x1200_300_rgb.jpg?v=1792646371"},{"product_id":"graduated-pipette-1000-l-hi731341","title":"Graduated Pipette (1000 µL) - HI731341","description":"\u003cp\u003eThe HI731341 Graduated Pipette is able to accurately transfer 1000 µL volumes of liquid that need to be precisely dosed. The liquid is aspirated into disposable tips, eliminating cross contamination of samples.\u003c\/p\u003e\n\u003cp\u003eBy simply pressing the pushbutton to the first stop, immersing the disposable tip into the sample, and slowly releasing the pushbutton, an accurate volume of 1000 µL of liquid is taken up. To dispense the liquid, users can press the pushbutton past the first stop to the second stop to ensure the full volume is expelled. The built-in tip ejector provides a hassle-free way for users to discard their HI731351 Plastic Pipette Tips.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI731341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eGraduated Pipette (1000 µL) - HI731341\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI731341\" target=\"_blank\" rel=\"noopener\"\u003eGraduated Pipette (1000 µL) - HI731341\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871394070897,"sku":"HI731341","price":16969.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731341.jpg?v=1792646372"},{"product_id":"graduated-pipette-200-l-hi731340","title":"Graduated Pipette (200 µL) - HI731340","description":"\u003cp\u003eThe HI731340 Graduated Pipette is able to accurately transfer 200 µL volumes of liquid that need to be precisely dosed. The liquid is aspirated into disposable tips, eliminating cross contamination of samples.\u003c\/p\u003e\n\u003cp\u003eBy simply pressing the pushbutton to the first stop, immersing the disposable tip into the sample, and slowly releasing the pushbutton, an accurate volume of 200 µL of liquid is taken up. To dispense the liquid, users can press the pushbutton past the first stop to the second stop to ensure the full volume is expelled. The built-in tip ejector provides a hassle-free way for users to discard their HI731350 Plastic Pipette Tips.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI731340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eGraduated Pipette (200 µL) - HI731340\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI731340\" target=\"_blank\" rel=\"noopener\"\u003eGraduated Pipette (200 µL) - HI731340\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871394103665,"sku":"HI731340","price":16969.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731340_1200x1200_300_rgb.jpg?v=1792646373"},{"product_id":"plastic-pipette-tips-1000-l-hi731351","title":"Plastic Pipette Tips (1000 µL) - HI731351","description":"\u003cp\u003eTogether,  the HI731341 Graduated Pipette and HI731351 Plastic Pipette Tips are able to accurately transfer 1000 µL volumes of liquid that need to be precisely dosed. The liquid is aspirated into disposable tips,  eliminating cross contamination of samples.\u003c\/p\u003e\n\u003cp\u003eBy simply pressing the pushbutton to the first stop,  immersing the disposable tip into the sample,  and slowly releasing the pushbutton,  an accurate volume of 1000 µL of liquid is taken up. To dispense the liquid,  users can press the pushbutton past the first stop to the second stop to ensure the full volume is expelled. The built-in tip ejector provides a hassle-free way for users to discard their plastic tips.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Plastic Pipette Tips (1000 µL) - HI731351\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Quantity: 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731351\"\u003ePlastic Pipette Tips (1000 µL) - HI731351\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871394169201,"sku":"HI731351","price":1833.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731351_1200x1200_240_rgb_1.jpg?v=1792646373"},{"product_id":"graduated-pipette-100-l-hi731339p","title":"Graduated Pipette (100 µL) - HI731339P","description":"\u003cp\u003eThe HI731339P Graduated Pipette is able to accurately transfer 100 µL of solution to a sample cuvette. The liquid is aspirated into disposable tips,  eliminating cross contamination of samples.\u003c\/p\u003e\n\u003cp\u003eBy simply pressing the pushbutton to the first stop,  immersing the disposable tip into the sample,  and slowly releasing the pushbutton,  an accurate volume of 100 µL of liquid is taken up. To dispense the liquid,  users then press the pushbutton past the first stop to the second stop to ensure the full volume is expelled. The HI731339P uses the HI731349P Plastic Pipette Tips.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731339P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Graduated Pipette (100 µL) - HI731339P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731339P\"\u003eGraduated Pipette (100 µL) - HI731339P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871394365809,"sku":"HI731339P","price":2766.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731339.jpg?v=1792646375"},{"product_id":"plastic-pipette-tips-2000-l-hi731352","title":"Plastic Pipette Tips (2000 µL) - HI731352","description":"\u003cp\u003eTogether,  the HI731342 Graduated Pipette and HI731352 Plastic Pipette Tips are able to accurately transfer 2000 µL volumes of liquid that need to be precisely dosed. The liquid is aspirated into disposable tips,  eliminating cross contamination of samples.\u003c\/p\u003e\n\u003cp\u003eBy simply pressing the pushbutton to the first stop,  immersing the disposable tip into the sample,  and slowly releasing the pushbutton,  an accurate volume of 2000 µL of liquid is taken up. To dispense the liquid,  users can press the pushbutton past the first stop to the second stop to ensure the full volume is expelled. The built-in tip ejector provides a hassle-free way for users to discard their plastic tips.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Plastic Pipette Tips (2000 µL) - HI731352\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Quantity: 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731352\"\u003ePlastic Pipette Tips (2000 µL) - HI731352\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871394398577,"sku":"HI731352","price":2348.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731352_1200x1200_300_rgb.jpg?v=1792646375"},{"product_id":"plastic-beaker-set-20-ml-10-hi740037p","title":"Plastic Beaker Set,  20 mL (10) - HI740037P","description":"\u003cp\u003eThe HI740037P is a set of 10 replacement plastic beakers used with Hanna test kits and various meters. While Hanna offers rugged plastic beakers in several different sizes,  the HI740037P are the  20 mL graduated beaker version.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740037P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Plastic Beaker Set, 20 mL (10) - HI740037P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Size: 5 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740037P\"\u003ePlastic Beaker Set, 20 mL (10) - HI740037P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871395676529,"sku":"HI740037P","price":2348.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740037p.jpg?v=1792646386"},{"product_id":"electrode-refilling-pipettes-20-pcs-hi740157p","title":"Electrode Refilling Pipettes (20 pcs.) - HI740157P","description":"\u003cp\u003eThe HI740157P electrode refilling pipettes allow for safe,  convenient,  and precise transfer of electrolyte fill solution into refillable Hanna electrodes. The plastic,  unified design of the pipettes is convenient for quickly refilling or topping off electrolyte solution,  ensuring there is adequate head pressure for measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740157P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Electrode Refilling Pipettes (20 pcs.) - HI740157P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Quantity: 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740157P\"\u003eElectrode Refilling Pipettes (20 pcs.) - HI740157P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871395774833,"sku":"HI740157P","price":1833.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi704157p.jpg?v=1792646387"},{"product_id":"test-tube-cooling-rack-hi740216","title":"Test Tube Cooling Rack - HI740216","description":"\u003cp\u003eThe HI740216 Test Tube Cooling Rack is able to hold up to 25 test tubes measuring 16 mm in diameter. When paired with the HI839800 COD Test Tube Heater,  customers are provided with an effective solution to their testing needs.\u003c\/p\u003e\n\u003cp\u003eAfter performing the heated digestion reaction for COD,  total nitrogen,  and total phosphorus analysis,  the test tube heater is turned off and the blank and reagent vials are allowed to cool for approximately 20 minutes. The test tube vials can are carefully removed from the test tube heater and placed in the cooling rack. Reagent vials should be near room temperature prior to determination with a COD photometer.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Test Tube Cooling Rack - HI740216\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Capacity: 25 vials (dia 16 x 100 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740216\"\u003eTest Tube Cooling Rack - HI740216\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871395938673,"sku":"HI740216","price":9600.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740216_1.jpg?v=1792646390"},{"product_id":"lab-safety-shield-hi740217","title":"Lab Safety Shield - HI740217","description":"\u003cp\u003eThe HI740217 is a lab safety shield designed for use with the HI839800 COD Test Tube Heater.\u003c\/p\u003e\n\u003cp\u003eWhile performing the heated digestion reaction for COD,  total nitrogen,  and total phosphorus analysis,  the HI740217 safety shield can be secured on top of the test tube heater. The durable plastic material is clear to allow users to visually monitor the display of the test tube heater. LED indicating lights are shown in addition to the temperature and countdown timer on the display screen.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Lab Safety Shield - HI740217\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740217\"\u003eLab Safety Shield - HI740217\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871395971441,"sku":"HI740217","price":18246.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740217_1.jpg?v=1792646390"},{"product_id":"plastic-beaker-set-170-ml-6-hi740224","title":"Plastic Beaker Set,  170 mL (6) - HI740224","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Plastic Beaker Set, 170 mL (6) - HI740224\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Quantity: 6\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740224\"\u003ePlastic Beaker Set, 170 mL (6) - HI740224\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871396954481,"sku":"HI740224","price":6808.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740224_1.jpg?v=1792646398"},{"product_id":"5-ml-syringe-for-mini-titrators-hi740236","title":"5 mL Syringe for Mini Titrators - HI740236","description":"\u003cp\u003eThe HI740236 replacement 5 mL plastic syringe allows for reliable titrant delivery and dosing for a variety of titrations. The syringe is easily replaced and can be connected in a matter of minutes. The HI845XX series of mini automatic titrators features a highly accurate titrant delivery system consisting of the 5 mL syringe driven by a dosing motor. The syringe,  along with the HI70500 tube set,  completes the replacement parts of the dosing system.\u003c\/p\u003e\n\u003cp\u003eThe HI740236 is used with the HI845XX series of mini titrators,  including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84500\u003c\/strong\u003e Sulfur Dioxide Mini Titrator for Wine Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84502\u003c\/strong\u003e Total Acidity Mini Titrator for Wine Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84529\u003c\/strong\u003e Titratable Acidity Mini Titrator for the Dairy Industry\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84530\u003c\/strong\u003e Titratable Acidity Mini Titrator for Water Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84531\u003c\/strong\u003e Titratable Alkalinity Mini Titrator for Water Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84532\u003c\/strong\u003e Titratable Acidity Mini Titrator for Fruit Juices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84533\u003c\/strong\u003e Formol Number Mini Titrator for Wines and Fruit Juices\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 5 mL Syringe for Mini Titrators - HI740236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740236\"\u003e5 mL Syringe for Mini Titrators - HI740236\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871397085553,"sku":"HI740236","price":1396.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740236-1200by1200-rgb.jpg?v=1792646399"},{"product_id":"stainless-steel-temperature-probe-hi7662","title":"Stainless Steel Temperature Probe - HI7662","description":"\u003cp\u003eHI7662 is a stainless steel temperature probe that can be used for compatible Hanna meters.\u003c\/p\u003e\n\u003cp\u003eHigh accuracy thermometers provide the versatility,  speed,  and reliability required by users in all areas concerning temperature measurement. Speed is important when the reactions being monitored have the potential to change rapidly.\u003c\/p\u003e\n\u003cp\u003epH readings must be temperature compensated in order to obtain accurate results. The source of temperature measurement can be from the HI7662 Temperature Sensor or from a trimmer that is manually adjusted. In either case,  the instrument is adjusting the pH reading to compensate for changes in the pH sensor. Temperature compensation provides the actual pH of the buffer or sample at the temperature of measurement.\u003c\/p\u003e\n\u003ch4\u003eTemperature compensation can be obtained in three ways:\u003c\/h4\u003e\n\u003col\u003e\n\u003cli\u003eA separate probe specifically for measuring temperature\u003c\/li\u003e\n\u003cli\u003eA probe with a temperature sensor built-in\u003c\/li\u003e\n\u003cli\u003eManual adjustment for temperature\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Stainless Steel Temperature Probe - HI7662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7662\"\u003eStainless Steel Temperature Probe - HI7662\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871409308017,"sku":"HI7662","price":9924.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7662.jpg?v=1792646491"},{"product_id":"holmium-oxide-glass-filter-for-spectrophotometers-hi801-11","title":"Holmium Oxide Glass Filter for Spectrophotometers - HI801-11","description":"\u003cp\u003eHolmium is a rare earth element that is silvery white and malleable. Holmium reacts with oxygen to form holmium oxide. Glasses that contain holmium oxide or holmium oxide solution are useful in the calibration of spectrophotometers due to their sharp absorption peaks in the visible spectrum. The National Institute of Technology (N.I.S.T.), formerly National Bureau of Standards (N.B.S.) uses a holmium oxide solution sealed into silica cuvettes as the standard reference material (SRM 2034) for traceability. The holmium oxide solution is prepared with holmium oxide dissolved in perchloric acid. This solution has many well-defined absorption bands. The SRM2034 was found to be stable for up to thirty years*\u003c\/p\u003e\n\u003cp\u003eThe HI801-11 is traceable to SRM2034 and is supplied with certificate of that identifies the peak absorbance values of the filter within 0.1 nm of uncertainty. The HI801-11 holmium oxide filter is used with the wavelength check mode found in the HI801 iris spectrophotometer. The filter is placed into the meter and the wavelength check mode is then used to verify the wavelength positioning. Once the check is complete the meter will display the wavelength peaks and they are compared to the values found on the certificate. The values should be within ±1.5 nm of the certified value.\u003c\/p\u003e\n\u003cp\u003e* NIST Special Publication 260-192\u003c\/p\u003e\n\u003ch5\u003eFEATURES\/BENEFITS:\u003c\/h5\u003e\n\u003ch5\u003eHolmium Oxide Filter\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSupplied with Certificate of Analysis\ntraceable to SRM2034\u003c\/li\u003e\n\u003cli\u003eAll values are certified and have an uncertainty of less than 0.1 nm\u003c\/li\u003e\n\u003cli\u003ePackaged in light tight plastic cuvette holder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI801-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eiris Visible Spectrophotometer - HI801\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e6.5 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Phenol Red method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 3.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e5 mAbs at 0.000-0.500 Abs 1% at 0.500-3.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 mg\/L (as CaCO3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 300 mg\/L (as CaCO3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.00 mg\/L (as Al3+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the aluminon method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003eLow Range:0.00 to 3.00 mg\/L (as NH3 -N)\nMedium Range: 0.00 to10.00 mg\/L (as NH3 -N)\nHigh Range: 0.0 to 100.0 mg\/L (as NH3 -N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003eLow and Medium Range: 0.01 mg\/L\nHigh Range: 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading\nMedium Range: ±0.05 mg\/L ±5% of reading\nHigh range: ±0.5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426 Nessler method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.50 mg\/L (as SDBS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 5540C, Anionic Surfactants as MBAS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 8.00 mg\/L (as Br2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Range\u003c\/td\u003e\n\u003ctd\u003e0 to 400 mg\/L (as Ca2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Oxalate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as ClO2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Chlorophenol Red method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 150 mg\/L (as O2 )\nMedium Range: 0 to 1500 mg\/L (as O2 )\nHigh Range: 0 to 15000 mg\/L (as O2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±5 mg\/L or ±4% of reading\nMedium Range: ±15 mg\/L or ±4% of reading\nHigh Range: ±150 mg\/L or ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA 410.4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L (as Cl)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±6% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercury(II) thiocyanate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as ClO2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Chlorophenol Red method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003eUltra Low Range : 0.000 to 0.500 mg\/L (as Cl2 )\nLow Range : 0.00 to 5.00 mg\/L (as Cl2)\nHigh Range : 0.00 to 10.00 mg\/L (as Cl2)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003eUltra Low Range : 0.001 mg\/\nLow Range : 0.01 mg\/L\nHigh Range : 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003eUltra Low Range : ±0.020 mg\/L ±3% of reading\nLow Range : ±0.03 mg\/L ±3% of reading\nHigh Range : ±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003eUltra Low Range : 0.000 to 0.500 mg\/L (as Cl2 )\nLow Range : 0.00 to 5.00 mg\/L (as Cl2)\nHigh Range : 0.00 to 10.00 mg\/L (as Cl2)\nUltra High Range : 0 to 500 mg\/L (as Cl2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003eUltra Low Range : 0.001 mg\/L\nLow Range : 0.01 mg\/L\nHigh Range : 0.01 mg\/L\nUltra High Range : 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003eUltra Low Range : ±0.020 mg\/L ±3% of reading\nLow Range : ±0.03 mg\/L ±3% of reading\nHigh Range : ±0.03 mg\/L ±3% of reading\nUltra High Range : ±3 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0 to 300 µg\/L (as Cr(VI))\nHigh Range : 0 to 1000 µg\/L (as Cr(VI))\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 1 µg\/L\nHigh Range : 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±10 µg\/L ±4% of reading\nHigh Range : ±5 µg\/L ±4% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1687, Diphenylcarbohydrazide method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 PCU (Platinum Cobalt Units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Resolution\u003c\/td\u003e\n\u003ctd\u003e1 PCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 PCU ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Colorimetric Platinum Cobalt method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Maple Syrup Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 100.00 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Maple Syrup Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 %T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Maple Syrup Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Maple Syrup Method\u003c\/td\u003e\n\u003ctd\u003eDirect measure\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.000 to 1.500 mg\/L (as Cu)\nHigh Range : 0.00 to 5.00 mg\/L (as Cu)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range :0.001 mg\/L\nHigh Range : 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.010 mg\/L ±5% of reading\nHigh Range : ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanide Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 0.200 mg\/L (as CN-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanide Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.005 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanide Method\u003c\/td\u003e\n\u003ctd\u003ePyridine-Pyrazalone\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±15% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.00 to 2.00 mg\/L (as F)\nHigh Range : 0.0 to 20.0 mg\/L (as F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.01 mg\/L\nHigh Range : 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.03 mg\/L ±3% of reading\nHigh Range : ±0.5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0 to 250 mg\/L (as CaCO3 )\nMedium Range : 200 to 500 mg\/L (as CaCO3 )\nHigh Range : 400 to 750 mg\/L (as CaCO3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±5 mg\/L ±4% of reading\nMedium Range : ±7 mg\/L ±3% of reading\nHigh Range : ±10 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA recommended method 130.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 mg\/L (as CaCO3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (CaCO3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, EDTA Colorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Range\u003c\/td\u003e\n\u003ctd\u003e0 to 400 µg\/L (as N2H4 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±4% of full scale reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, method D1385, p-Dimethylaminobenzaldehyde method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 12.5 mg\/L (as I2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.000 to 1.600 mg\/L (as Fe)\nHigh Range : 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.001 mg\/L\nHigh Range : 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.010 mg\/L ±8% of reading\nHigh Range : ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eLow Range : Adaptation of the TPTZ Method\nHigh Range : Adaptation of the EPA Phenanthroline method 315B, for natural and treated waters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as Mg2+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0 to 300 µg\/L (as Mn)\nHigh Range : 0.0 to 20.0 mg\/L (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 1 µg\/L\nHigh Range : 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±10 µg\/L ±3% of reading\nHigh Range : ±0.2 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003eLow Range : Adaptation of the PAN Method\nHigh Range : Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo6+)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.000 to 1.000 mg\/L (as Ni)\nHigh Range : 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.001 mg\/L\nHigh Range : 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.010 mg\/L ±7% of reading\nHigh Range : ±0.07g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003eLow Range : Adaptation of the PAN method\nHigh Range : Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO3 - N)\nChromotropic Acid : 0.0 to 30.0 mg\/L (as N03--N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\nChromotropic Acid : ±1.0 mg\/L or ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\nChromotropic Acid : Chromotropic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003eMarine Ultra Low Range : 0 to 200 µg\/L (as N02 -N)\nLow Range : 0 to 600 µg\/L (as NO2 -N)\nHigh Range : 0 to 150 mg\/L (as NO2-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003eMarine Ultra Low Range : 1 µg\/L\nLow Range : 1 µg\/L\nHigh Range : 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003eMarine Ultra Low Range : ±10 µg\/L ±4% of reading\nLow Range : ±20 µg\/L ±4% of reading\nHigh Range : ±4 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eMarine Ultra Low Range : Adaptation of the EPA Diazotization method 354.1\nLow Range : Adaptation of the EPA Diazotization method 354.1\nHigh Range : Adaptation of the Ferrous Sulfate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.0 to 25.0 mg\/L (as N)\nHigh Range : 10 to 150 mg\/L (as N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.1 mg\/L\nHigh Range : 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±1.0 mg\/L or ±5% of reading\nHigh Range : ±3 mg\/L or ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Method\u003c\/td\u003e\n\u003ctd\u003eChromotropic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Range\u003c\/td\u003e\n\u003ctd\u003eCarbohydrazide : 0.00 to 1.50 mg\/L (as Carbohydrazide)\nDiethylhydroxylamine)(DEHA) : 0 to 1000 µg\/L (as DEHA)\nHydroquinone : 0.00 to 2.50 mg\/L (as Hydroquinone)\nIso-ascorbic Acid :0.00 to 4.50 mg\/L (as Iso-ascorbic acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Resolution\u003c\/td\u003e\n\u003ctd\u003eCarbohydrazide : 0.01 mg\/L\nDiethylhydroxylamine)(DEHA) : 1 µg\/L\nHydroquinone : 0.01 mg\/L\nIso-ascorbic Acid : 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Accuracy\u003c\/td\u003e\n\u003ctd\u003eCarbohydrazide : ±0.02 mg\/L ±3% of reading\nDiethylhydroxylamine)(DEHA) : ±5 µg\/L ±5% of reading\nHydroquinone : ±0.04 mg\/L ±3% of reading\nIso-ascorbic Acid : ±0.03 mg\/L ±3 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the iron reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O3 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.00 to 2.50 mg\/L (as PO4 3-)\nHigh Range : 0.0 to 30.0 mg\/L (as PO4 3-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.01 mg\/L\nHigh Range : 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.04 mg\/L ±4% of reading\nHigh Range : ±1.0 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eLow Range : Adaptation of the Ascorbic Acid method\nHigh Range : Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.60 mg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 mg\/L or ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-P E, ascorbic acid method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.00 to 1.60 mg\/L (as P)\nHigh Range : 0.0 to 32.6 mg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.01 mg\/L\nHigh Range : 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.05 mg\/L or ±4% of reading\nHigh Range : ±0.5 mg\/L or ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-P E, ascorbic acid method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.00 to 1.15 mg\/L (as P)\nHigh Range : 0.0 to 32.6 mg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.01 mg\/L\nHigh Range : 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.05 mg\/L or ±6% of reading\nHigh Range : ±0.5 mg\/L or ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Method\u003c\/td\u003e\n\u003ctd\u003eLow Range : Adaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-P E, ascorbic acid method.\nHigh Range : Adaptation of the Standard Methods for the Examination of Water and Wastewate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.0 to 20.0 mg\/L (as K)\nMedium Range : 10 to 100 mg\/L (as K)\nHigh Range : 20 to 200 mg\/L (as K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.1 mg\/L\nMedium Range : 1 mg\/L\nHigh Range : 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±2 mg\/L ±7% of reading\nMedium Range : ±10 mg\/L ±7% of reading\nHigh Range : ±20 mg\/L ±7% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Turbidimetric Tetraphenylborate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.00 to 2.00 mg\/L (as SiO2 )\nHigh Range : 0 to 200 mg\/L (as SiO2 )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range : 0.01 mg\/L\nHigh Range : 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range : ±0.03 mg\/L ±3% of reading\nHigh Range : ±1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eLow Range : Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method\nHigh Range : Adaptation of the USEPA Method 370.1 for drinking, surface and saline waters, domestic and industrial wastes and\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as SO42-)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Method\u003c\/td\u003e\n\u003ctd\u003eSulfate is precipitated with barium chloride crystals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Range\u003c\/td\u003e\n\u003ctd\u003e340 to 900 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Resolution\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Modes\u003c\/td\u003e\n\u003ctd\u003eTransmittance (% T), absorbance (abs), concentration with choice of units (ppm, mg\/L, ppt, ºf, ºe, ppb, meq\/L, μg\/L, PCU, Pfund, pH, dKH, ºdH, meq\/kg or no measurement unit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Selection\u003c\/td\u003e\n\u003ctd\u003eautomatic, based on the selected method (editable for user methods only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical System\u003c\/td\u003e\n\u003ctd\u003esplit beam sample and reference light detectors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength Calibration\u003c\/td\u003e\n\u003ctd\u003einternal, automatic at power-on, visual feedback\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points Stored\u003c\/td\u003e\n\u003ctd\u003eup to 9999 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport Capability\u003c\/td\u003e\n\u003ctd\u003e.csv file format, .pdf file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e(1) USB - A (mass storage host); (1) USB - B (mass storage device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e15 VDC power adapter; 10.8 VDC Li-Ion rechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3000 measurements or 8 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); 0 to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg (6.6 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e155 x 205 x 322 mm (6.1 x 8.0 x 12.6*rdquo;)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI801 is supplied with 22 mm sample cuvette and cap (4), 10 mm square, 13 mm round and 16 mm round cuvette adapters, cloth for wiping cuvettes, scissors, USB cable, lithium ion rechargeable battery, 115VAC to 15VDC power adapter, USB drive, instruction manual, and instrument quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003ehttps:\/\/manuals.hannainst.com\/HI801-01\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871414747505,"sku":"HI801-11","price":41408.55,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi801-11_holmium-filter-15.jpg?v=1792646539"}],"url":"https:\/\/hannainst.in\/collections\/lab-supplies-accessories.oembed","provider":"hanna","version":"1.0","type":"link"}