{"title":"Process Control – Mini Controllers","description":"","products":[{"product_id":"orp-mini-controller-with-analog-output-bl932700-115-230vac","title":"ORP Mini Controller with Analog Output - BL932700-115\/230VAC","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL932700_angle.jpg\" alt=\"BL932700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAdjustable Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL932700 features a dosing relay which may be configured to dose above or below a user programmable mV setpoint.\u003c\/p\u003e\n\u003ch4\u003eSelectable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eThe mini controller may be programmed to deactivate a valve,  pump,  or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes.\u003c\/p\u003e\n\u003ch4\u003eSelectable Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch,  normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.”\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL932700_rear.jpg\" alt=\"BL932700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAnalog Output Communication\u003c\/h4\u003e\n\u003cp\u003eThe BL932700 features a 4 - 20 mA analog output for connection to a data logger,  chart recorder,  or other device.\u003c\/p\u003e\n\u003ch4\u003eExternal Disabling Feature\u003c\/h4\u003e\n\u003cp\u003eA normally open contact may connect to a level controller or flow monitor. This safety feature may be used to prevent continuous dosing in the event of specific or undesired system conditions.\u003c\/p\u003e\n\u003ch4\u003eMatching Pin Connection\u003c\/h4\u003e\n\u003cp\u003eAn included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL932700-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e ORP Mini Controller with Analog Output - BL932700-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e ±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e  maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from -1000 to 1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable from -1000 to 1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Terminals\u003c\/td\u003e\n\u003ctd\u003e reducing or oxidizing, selectable on the back panel \u003cbr\u003econtact open=reductant dosage=relay ON if measurement \u0026gt; setpoint \u003cbr\u003econtact closed=oxidant dosage=relay ON if measurement \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e 4 to 20 mA, accuracy ±0.20 mA, 500 Ω maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e  BL932700-0: 12 VDC adapter (included); \u003cbr\u003eBL932700-1: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e BL932700-0: 200 g (7.1 oz.)\u003cbr\u003eBL932700-1: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL932700-0 (12 VDC) and BL932700-1 ( 115\/230V) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL932700-1\"\u003eORP Mini Controller with Analog Output - BL932700-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162728817,"sku":"BL932700-1","price":30117.0,"currency_code":"INR","in_stock":true}]},{"product_id":"orp-mini-controller-bl982411-115-230vac","title":"ORP Mini Controller – BL982411-115\/230VAC","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL982411_angle.jpg\" alt=\"BL982411\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAdjustable Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL982411 features a dosing relay which may be configured to dose above or below a user programmable mV setpoint.\u003c\/p\u003e\n\u003ch4\u003eSelectable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eThe mini controller may be programmed to deactivate a valve,  pump,  or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes.\u003c\/p\u003e\n\u003ch4\u003eSelectable Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch,  normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.”\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL982411_rear.jpg\" alt=\"BL982411\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe mini controller is protected for up to a 2A load from a connected pump or device.\u003c\/p\u003e\n\u003ch4\u003eEasy Peripheral Connection\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks provide for easy connection to power,  communication,  dosing control,  or sensors.\u003c\/p\u003e\n\u003ch4\u003eMatching Pin Connection\u003c\/h4\u003e\n\u003cp\u003eAn included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL982411-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e ORP Mini Controller – BL982411-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 199.9 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 199.9 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Terminals\u003c\/td\u003e\n\u003ctd\u003e reducing or oxidizing, selectable on the back panel  contact open=reductant dosage=relay ON if measurement \u0026gt; setpoint  contact closed=oxidant dosage=relay ON if measurement \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983315-1 (115\/230 VAC) and BL983315-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL982411-1\"\u003eORP Mini Controller – BL982411-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162761585,"sku":"BL982411-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"conductivity-mini-controller-0-1999-s-cm-115-230vac-bl983313-1","title":"Conductivity Mini Controller (0 - 1999 µS\/cm) 115\/230VAC - BL983313-1","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313_angle.jpg\" alt=\"BL983313\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983313 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313_rear.jpg\" alt=\"BL983313\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983313 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983313-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity Mini Controller (0 - 1999 µS\/cm) 115\/230VAC - BL983313-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026gt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983313-1 (115\/230 VAC) and BL983313-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983313-1\"\u003eConductivity Mini Controller (0 - 1999 µS\/cm) 115\/230VAC - BL983313-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162794353,"sku":"BL983313-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"conductivity-mini-controller-0-1999-s-cm-230vac-4-20-ma-output-bl983313-2","title":"Conductivity Mini Controller (0 - 1999 µS\/cm) | 230VAC \/ 4-20 mA Output- BL983313-2","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313_angle.jpg\" alt=\"BL983313\" width=\"410\" height=\"410\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983313 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313_rear.jpg\" alt=\"BL983313\" width=\"410\" height=\"410\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" width=\"411\" height=\"284\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983313 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-Front-View-300x300.jpg\" alt=\"\" width=\"410\" height=\"410\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL983313-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eConductivity Mini Controller (0 - 1999 µS\/cm) 230VAC \/ 4-20 mA Output- BL983313-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003econtact closed when measure \u0026gt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL983313-2\" target=\"_blank\" rel=\"noopener\"\u003eConductivity Mini Controller (0 - 1999 µS\/cm) 115\/230VAC \/ 4-20 mA Output- BL983313-2\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162827121,"sku":"BL983313-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313.png?v=1792645809"},{"product_id":"resistivity-mini-controller-bl983314-115-230vac","title":"Resistivity Mini Controller - BL983314-115\/230VAC","description":"\u003ch4\u003eAbout the BL983314 Resistivity Mini Controllers\u003c\/h4\u003e\n\u003cp\u003eReadings are automatically temperature compensated with three different coefficients (β=2.4,  3.5 or 4.5 %\/℃). The alarm contact can be used for connection to an alarm,  pump,  solenoid or dosing system.\u003c\/p\u003e\n\u003cp\u003eThe relay contact is open when readings are higher than the setpoint,  while for measurements lower than setpoint,  the relay contact is closed. The hysteresis is typically 0.20 Mω •cm from the setpoint.\u003c\/p\u003e\n\u003cp\u003eMeasurements are displayed on the LCD and the multi-coloured LED continuously indicates if the controller is in measurement,  dosing,  or alarm mode. Users can choose automatic or manual dosing mode with a switch on the front panel. Manual control is particularly useful during maintenance operations,  because it permits operators to enable or disable the dosing relay according to need.\u003c\/p\u003e\n\u003cp\u003eThe overtime control system advises users when the relay is active for too long,  helping to prevent over-dosage.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983314-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Resistivity Mini Controller - BL983314-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 19.90 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.10 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003e factory calibrated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 Vdc contact closed when measure \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 19.90 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e 10 VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Probe\u003c\/td\u003e\n\u003ctd\u003e HI3314 resistivity probe with 2 m (6.6’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e BL983314-0: 12 VDC adapter (included); BL983314-1: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3x2.1x3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e BL983314-0: 200 g (7.1 oz.); BL983314-1: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983314-0 (12 VDC) and BL983314-1 (115\/230V) are supplied with HI3314 resistivity probe with 2 m (6.6’) cable, mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983314-1\"\u003eResistivity Mini Controller - BL983314-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871165972849,"sku":"BL983314-1","price":30117.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl983314_front_2.jpg?v=1792645806"},{"product_id":"tds-mini-controller-0-0-to-199-9-ppm-bl983315-115-230vac","title":"TDS Mini Controller (0.0 to 199.9 ppm) - BL983315-115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_angle.jpg\" alt=\"BL983315\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_rear.jpg\" alt=\"BL983315\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983315-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0.0 to 199.9 ppm) - BL983315-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 199.9 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 199.9 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983315-1 (115\/230 VAC) and BL983315-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983315-1\"\u003eTDS Mini Controller (0.0 to 199.9 ppm) - BL983315-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166005617,"sku":"BL983315-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"tds-mini-controller-0-0-to-199-9-ppm-bl983315-2-230-vac-output-4-20-ma","title":"TDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 230 VAC,  Output: 4-20 mA","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThis compact, panel mounted, process controller is ideal for measuring total dissolved solids (TDS) of a process stream. This controller features a large LCD with protective cover. Users may choose from automatic or manual dosing modes.\u003c\/p\u003e\n\u003cp\u003eWhen in automatic mode, the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983315 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_angle.jpg\" alt=\"BL983315\" width=\"500\" height=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_rear.jpg\" alt=\"BL983315\" width=\"500\" height=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003cp\u003eBL983315 uses a 0.5 conversion factor in which 1.0 µS\/cm = 0.5 ppm.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel available with 4-20 mA galvanic isolated output with external dosing disable contact\u003c\/li\u003e\n\u003cli\u003eLarge Clear LCD\u003c\/li\u003e\n\u003cli\u003eFire Retardant Casing\u003c\/li\u003e\n\u003cli\u003eSplash-Resistant Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" width=\"600\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL983315-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 230 VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 199.9 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 12 VDC adapter (included)\nmodels “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL983315-2\" target=\"_blank\" rel=\"noopener\"\u003eTDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 115\/230 VAC, Output: 4-20 mA\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166038385,"sku":"BL983315-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315-2.png?v=1792645812"},{"product_id":"tds-mini-controller-0-00-to-10-00-ppt-bl983318-115-230vac","title":"TDS Mini Controller (0.00 to 10.00 ppt) - BL983318 -115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983318-1.jpg\" alt=\"BL983318\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983318 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is active.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983318_rear.jpg\" alt=\"BL983318\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7632.jpg\" alt=\"HI7632\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983318 mini controller uses the \u003cstrong\u003eHI7632\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7632 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983318-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0.00 to 10.00 ppt) - BL983318 -115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 10.00 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 10 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983318-0 (12 VDC) and BL983318-1 (115\/230 VAC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983318-1\"\u003eTDS Mini Controller (0.00 to 10.00 ppt) - BL983318 -115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166071153,"sku":"BL983318-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"conductivity-mini-controller-0-00-10-00-ms-cm-bl983317-12vdc","title":"Conductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-12VDC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317_angle.jpg\" alt=\"BL983317\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983317 features a dosing relay that is activated when the reading is below a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is above the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is below the set point and the relay is active.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317_rear.jpg\" alt=\"BL983317\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7632.jpg\" alt=\"HI7632\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983317 mini controller uses the \u003cstrong\u003eHI7632\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7632 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983317-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-12VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 10 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983317-0 (12 VDC) and BL983317-1 (115\/230 VAC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983317-1\"\u003eConductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-12VDC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166103921,"sku":"BL983317-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"ph-mini-controller-with-analog-output-bl931700","title":"pH Mini Controller with Analog Output - BL931700-1","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL931700_angle.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eEnhanced Accuracy \u0026amp; Precision\u003c\/h4\u003e\n\u003cp\u003eThe BL931700 model offers a manual two-point calibration with pH values displayed out to two decimal places.\u003c\/p\u003e\n\u003ch4\u003eExternal Disabling Feature\u003c\/h4\u003e\n\u003cp\u003eA normally open contact may connect to a level controller or flow monitor. This safety feature may be used to prevent continuous dosing in the event of specific or undesired system conditions.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL931700 features a dosing relay which may be configured to dose above or below a user programmable pH setpoint.\u003c\/p\u003e\n\u003ch4\u003eSelectable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eThe mini controller may be programmed to deactivate a valve,  pump,  or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes.\u003c\/p\u003e\n\u003ch4\u003eSelectable Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch,  normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.”\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL931700_rear.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAnalog Output Communication\u003c\/h4\u003e\n\u003cp\u003eThe BL931700 features a 4 - 20 mA analog output for connection to a data logger,  chart recorder,  or other device.\u003c\/p\u003e\n\u003ch4\u003eMatching Pin Connection\u003c\/h4\u003e\n\u003cp\u003eAn included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.\u003c\/p\u003e\n\u003ch4\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe mini controller is protected for up to a 2A load from the connected pump or device.\u003c\/p\u003e\n\u003ch4\u003eEasy Peripheral Connection\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks provide for easy connection to power,  communication,  dosing control,  or sensors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL931700-web\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH Mini Controller with Analog Output - BL931700\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, 2 points through offset and slope trimmers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e 10¹² Ohm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 14 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e 4 to 20 mA, accuracy ±0.20 mA, 500 Ω maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e BL931700-0: 12 VDC adapter (included); \u003cbr\u003eBL931700-1: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e BL931700-0: 200 g (7.1 oz.);\u003cbr\u003eBL931700-1: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL931700-0 (12 VDC) and BL931700-1 (115\/230 VAC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL931700-web\"\u003epH Mini Controller with Analog Output - BL931700\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166136689,"sku":"BL931700-1","price":40657.95,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl931700_front.jpg?v=1792645810"},{"product_id":"tds-mini-controller-0-to-1999-ppm-bl983319-1-115-230vac","title":"TDS Mini Controller (0 to 1999 ppm) - BL983319-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983319_angle.jpg\" alt=\"BL983319\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983319 features a dosing relay that is activated when the reading is below a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983319_rear.jpg\" alt=\"BL983319\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983319 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983319-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0 to 1999 ppm) - BL983319-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 1999 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 1999 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983319-1 (115\/230 VAC) and BL983319-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983319-1\"\u003eTDS Mini Controller (0 to 1999 ppm) - BL983319-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166366065,"sku":"BL983319-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"conductivity-ec-controller-0-0-199-9-s-cm-bl983320-1-115-230vac","title":"Conductivity (EC) Controller (0.0 - 199.9 µS\/cm) - BL983320-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983320_angle.jpg\" alt=\"BL983320\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983320 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983320_rear.jpg\" alt=\"BL983320\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983320 mini controller uses the \u003cstrong\u003e\u003ca href=\"https:\/\/www.hannainst.com\/ec-tds-probe-for-low-range-mini-controllers.html\" target=\"_blank\" rel=\"noopener\"\u003eHI7634\u003c\/a\u003e\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983320-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity (EC) Controller (0.0 - 199.9 µS\/cm) - BL983320-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026gt; setpoint \u003cbr\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983320-1 (115\/230 VAC) and BL983320-0 (12 VDC) supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983320-1\"\u003eConductivity (EC) Controller (0.0 - 199.9 µS\/cm) - BL983320-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871168561521,"sku":"BL983320-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"conductivity-ec-mini-controller-0-0-199-9-s-cm-bl983320-2-230vac-output-4-20-ma","title":"Conductivity (EC) Mini Controller (0.0 - 199.9 µS\/cm) - BL983320-2 | 230VAC,  Output: 4-20 mA","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThis compact, panel mounted, process controller is for measuring electrolytic conductivity (EC) of a process stream. Users may choose from automatic or manual dosing modes. When in automatic mode the dry contact relay is activated when a reading is above the set point.\u003c\/p\u003e\n\u003cp\u003eBL983320's relay can be used to activate a solenoid that switches from one DI (deionized) tank to another or to open a valve that will allow lower EC water to flow into a tank being monitored in order to lower its EC. The BL983320 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983320_angle.jpg\" alt=\"BL983320\" width=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983320 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983320_rear.jpg\" alt=\"BL983320\" width=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" width=\"800\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983320 mini controller uses the \u003cstrong\u003e\u003ca href=\"\/hi7634-ec-tds-probe-for-mini-controller-low-range.html\" target=\"_blank\" rel=\"noopener\"\u003eHI7634\u003c\/a\u003e\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL983320-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eConductivity (EC) Mini Controller (0.0 - 199.9 µS\/cm) - BL983320-2 | 115\/230VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003eβ =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003econtact closed when measure \u0026gt; setpoint\nmaximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eadjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_BLCONTROLLERS_1p1_1222.pdf\"\u003eHanna BL Series Product Literature\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871168627057,"sku":"BL983320-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI983320.png?v=1792645813"},{"product_id":"tds-mini-controller-0-00-to-19-99-ppm-bl983321-115-230vac","title":"TDS Mini Controller (0.00 to 19.99 ppm) - BL983321-115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983321_angle.jpg\" alt=\"BL983321\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983321 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983321_rear.jpg\" alt=\"BL983321\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983321 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983321-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0.00 to 19.99 ppm) - BL983321-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 19.99 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 19.99 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983321-1 (115\/230 VAC) and BL983321-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983321-1\"\u003eTDS Mini Controller (0.00 to 19.99 ppm) - BL983321-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871168659825,"sku":"BL983321-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"conductivity-controller-0-00-to-19-99-s-cm-bl983322-1-115-230vac","title":"Conductivity Controller (0.00 to 19.99 µS\/cm) - BL983322-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983322_angle.jpg\" alt=\"BL983322\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983322 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983322_rear.jpg\" alt=\"BL983322\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983322 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003ch4\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983322-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity Controller (0.00 to 19.99 µS\/cm) - BL983322-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e  ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983322-1 (115\/230 VAC) and BL983322-0 (12 VDC) supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983322-1\"\u003eConductivity Controller (0.00 to 19.99 µS\/cm) - BL983322-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871168692593,"sku":"BL983322-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"tds-mini-controller-0-0-to-49-9-ppm-bl983324-115-230vac","title":"TDS Mini Controller (0.0 to 49.9 ppm) - BL983324-115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983324_angle.jpg\" alt=\"BL983324\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983324 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983324_rear.jpg\" alt=\"BL983324\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983324 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983324-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0.0 to 49.9 ppm) - BL983324-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 49.9 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mg\/L ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983324-1 (115\/230 VAC) and BL983324-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983324-1\"\u003eTDS Mini Controller (0.0 to 49.9 ppm) - BL983324-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170429297,"sku":"BL983324-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"tds-mini-controller-0-to-999-ppm-bl983329-1-115-230vac","title":"TDS Mini Controller (0 to 999 ppm) - BL983329-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983329_angle.jpg\" alt=\"BL983329\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983329 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983329_rear.jpg\" alt=\"BL983329\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983329 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983329-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0 to 999 ppm) - BL983329-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 999 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 999 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026gt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983329-1 (115\/230 VAC) and BL983329-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983329-1\"\u003eTDS Mini Controller (0 to 999 ppm) - BL983329-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170527601,"sku":"BL983329-1","price":22547.0,"currency_code":"INR","in_stock":true}]},{"product_id":"conductivity-mini-controller-0-00-10-00-ms-cm-bl983317-2-230vac-output-4-20-ma","title":"Conductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-2 | 230VAC, Output: 4-20 mA","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe BL983317 is a compact, panel mounted, process controllers for measuring conductivity of a process stream. The device features a large LCD with protective cover. Users may choose from automatic or manual dosing modes.\u003c\/p\u003e\n\u003cp\u003eWhen in automatic mode, the dry contact relay is activated when a reading is below the set point. The relay can be used to activate a dosing pump to add chemical until the desired set point is reached. Chemicals that can be dosed include nutrient solutions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317-2-BL-Series-Controllers-1-300x300.jpg\" alt=\"The BL983317 is a compact, panel mounted, process controller for measuring conductivity of a process stream. \" width=\"410\" height=\"410\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983317 features a dosing relay that is activated when the reading is below a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is above the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is below the set point and the relay is active.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317-2-BL-Series-Controllers-Rear-image-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317-2-BL-Series-Controllers-HI7632-probe-300x208.jpg\" alt=\"HI7632 Probe for BL983317-2 Mini controllers\" width=\"411\" height=\"285\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983317 mini controller uses the \u003cstrong\u003eHI7632\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-Front-View-300x300.jpg\" alt=\"BL983317-2 Hanna BL Series Controller Rear View\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7632 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-300x300.jpg\" alt=\"Side view of BL Series Mini Controllers\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL983317-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eConductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-2 | 230VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/\u003csup\u003eo\u003c\/sup\u003eC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 12 VDC adapter (included)\nmodels “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983317-2 (230VAC) is supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458099569,"sku":"BL983317-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317.png?v=1792646954"},{"product_id":"tds-mini-controller-0-to-1999-ppm-bl983319-2-230vac-output-4-20-ma","title":"TDS Mini Controller (0 to 1999 ppm) - BL983319-2 | 230VAC, Output: 4-20 mA","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThis compact, panel mounted, process controller is ideal for measuring total dissolved solids (TDS) of a process stream. This controller features a large LCD with protective cover. Users may choose from automatic or manual dosing modes.\u003c\/p\u003e\n\u003cp\u003eWhen in automatic mode, the dry contact relay is activated when a reading is below the set point. The relay can be used to supply power to a dosing pump to add fertilizer to a nutrient solution in order to maintain an ideal concentration.\u003c\/p\u003e\n\u003cp\u003eBL983319 uses a 0.65 conversion factor in which 100 μ S\/cm = 65 ppm.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel available with 4-20 mA galvanic isolated output with external dosing disable contact\u003c\/li\u003e\n\u003cli\u003eLarge Clear LCD\u003c\/li\u003e\n\u003cli\u003eFire Retardant Casing\u003c\/li\u003e\n\u003cli\u003eSplash-Resistant Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983319_front-3600x3600-4ac6c371-1e32-4d-300x300.jpg\" alt=\"BL983319-2 Mini Controller for EC measurements\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983319 features a dosing relay that is activated when the reading is below a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983319_rear-3300x3300-fae2712c-3c60-45f-300x300.jpg\" alt=\"Rear view of BL983319\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-3502x3503-d9358726-5b43-4766-b483--300x300.jpg\" alt=\"HI7634 probe for BL983319-2\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983319 mini controller uses the \u003cstrong\u003e\u003ca href=\"\/hi7634-ec-tds-probe-for-mini-controller-low-range.html\" target=\"_blank\" rel=\"noopener\"\u003eHI7634\u003c\/a\u003e\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-Front-View-300x300.jpg\" alt=\"BL983317-2 Hanna BL Series Controller Rear View\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-300x300.jpg\" alt=\"Side view of BL Series Mini Controllers\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI983319-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTDS Mini Controller (0 to 1999 ppm) - BL983319-2 | 230VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1999 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 VAC, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 1999 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003econtact closed when measure \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eadjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e230VAC; 50\/60Hzs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983319-2 (230VAC) is supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_BLCONTROLLERS_1p1_1222.pdf\"\u003eHanna BL983319 Product Literature\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458132337,"sku":"BL983319-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983319.png?v=1792646953"},{"product_id":"conductivity-controller-0-00-to-19-99-s-cm-bl983322-2-230vac-output-4-20-ma","title":"Conductivity Controller (0.00 to 19.99 μS\/cm) - BL983322-2 | 230VAC, Output: 4-20 mA","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl983322_front-300x300.jpg\" alt=\"Conductivity Controller (0.00 to 19.99 μS\/cm) - BL983322-2 | 220V, Output: 4-20 mA\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983322 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983322_rear-2100x2100-bfebfac4-2c6b-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-3502x3503-d9358726-5b43-4766-b483--300x300.jpg\" alt=\"HI7634 probe for BL983319-2\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983322 mini controller uses the \u003cstrong\u003e\u003ca href=\"\/hi7634-ec-tds-probe-for-mini-controller-low-range.html\" target=\"_blank\" rel=\"noopener\"\u003eHI7634\u003c\/a\u003e\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-Front-View-300x300.jpg\" alt=\"BL983317-2 Hanna BL Series Controller Rear View\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-300x300.jpg\" alt=\"Side view of BL Series Mini Controllers\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI983322-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eConductivity Controller (0.00 to 19.99 μS\/cm) - BL983322-2 | 230VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 19.99 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 VAC, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 19.99 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eadjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e230VAC; 50\/60Hzs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983322-2 (230VAC) is supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_BLCONTROLLERS_1p1_1222.pdf\"\u003eHanna BL Series Product Literature\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458165105,"sku":"BL983322-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983322.png?v=1792646953"},{"product_id":"tds-mini-controller-0-to-999-ppm-bl983329-2-230vac-output-4-20-ma","title":"TDS Mini Controller (0 to 999 ppm) - BL983329-2 | 230VAC, Output: 4-20 mA","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983329_front-2100x2100-315e0372-9605-49-300x300.jpg\" alt=\"TDS Mini Controller (0 to 999 ppm) - BL983329-2 | 220VAC, Output: 4-20 mA\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983329 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983329_rear-2100x2100-9e9af798-457a-300x300.jpg\" alt=\"TDS Mini Controller (0 to 999 ppm) - BL983329-2 | 220VAC, Output: 4-20 mA\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-3502x3503-d9358726-5b43-4766-b483--300x300.jpg\" alt=\"HI7634 probe for BL983319-2\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983329 mini controller uses the \u003cstrong\u003e\u003ca href=\"\/hi7634-ec-tds-probe-for-mini-controller-low-range.html\" target=\"_blank\" rel=\"noopener\"\u003eHI7634\u003c\/a\u003e\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL983329-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTDS Mini Controller (0 to 999 ppm) - BL983329-2 | 230VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 999 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eadjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003econtact closed when measure \u0026gt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e220VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9’’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983329-2 (230VAC) is supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_BLCONTROLLERS_1p1_1222.pdf\"\u003eHanna BL Series Product Literature\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458230641,"sku":"BL983329-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983329.png?v=1792646955"},{"product_id":"conductivity-mini-controller-0-00-10-00-ms-cm-bl983327-2-220vac-output-4-20-ma","title":"Conductivity Mini Controller (0.00-10.00 mS\/cm) - BL983327-2 | 220VAC, Output: 4-20 mA","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983327_front-2100x2100-9ee5cfa6-4aef-41-300x300.jpg\" alt=\"Conductivity Mini Controller (0.00-10.00 mS\/cm) - BL983327-2 | 220VAC, Output: 4-20 mA\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983327 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is active.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983327_rear-2100x2100-7ef9be8b-7f75-4b7-300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7632-2100x2100-15de3c98-5644-4496-bf7b--300x300.jpg\" alt=\"\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983327 mini controller uses the \u003cstrong\u003e\u003ca href=\"\/hi7632-ec-tds-probe-for-mini-controller-high-range.html\" target=\"_blank\" rel=\"noopener\"\u003eHI7632\u003c\/a\u003e\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-Front-View-300x300.jpg\" alt=\"BL983317-2 Hanna BL Series Controller Rear View\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7632 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-2-300x300.jpg\" alt=\"Side view of BL Series Mini Controllers\" width=\"300\" height=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458197873,"sku":null,"price":23480.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983327.png?v=1792646955"},{"product_id":"ph-mini-controller-bl981411","title":"pH Mini Controller – BL981411-1","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL981411_angle.jpg\" alt=\"BL981411\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAdjustable Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL981411 features a dosing relay which may be configured to dose above or below a user programmable pH setpoint.\u003c\/p\u003e\n\u003ch4\u003eSelectable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eThe mini controller may be programmed to deactivate a valve, pump, or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes.\u003c\/p\u003e\n\u003ch4\u003eSelectable Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch, normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.”\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL981411_rear.jpg\" alt=\"BL981411\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe mini controller is protected for up to a 2A load from a connected pump or device.\u003c\/p\u003e\n\u003ch4\u003eEasy Peripheral Connection\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks provide for easy connection to power, communication, dosing control, or sensors.\u003c\/p\u003e\n\u003ch4\u003eMatching Pin Connection\u003c\/h4\u003e\n\u003cp\u003eAn included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL981411-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003epH Mini Controller – BL981411\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, through CAL (offset) trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eacid or alkaline\u003cbr\u003e\ncontact open=acid dosage=relay ON if measurement \u0026gt; setpoint\u003cbr\u003e\ncontact closed=alkaline dosage=relay ON if measurement \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003eBL981411-0: 12 VDC adapter (included);\u003cbr\u003e\nBL981411-1: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eBL981411-0: 200 g (7.1 oz.);\u003cbr\u003e\nBL981411-1: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL981411-0 (12 VDC) and BL981411-1 (115\/230V) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL981411-web\"\u003epH Mini Controller – BL981411\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871462097265,"sku":"BL981411-1","price":30438.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl981411_front.jpg?v=1792646988"}],"url":"https:\/\/hannainst.in\/collections\/mini-controllers-process-control.oembed","provider":"hanna","version":"1.0","type":"link"}