{"title":"Benchtop Meters – Multiparameter","description":"","products":[{"product_id":"multiparameter-modular-system-ph-orp-ph-orp-ise-ec-and-do-hi6000","title":"Multiparameter Modular System - pH\/ORP, pH\/ORP\/ISE, EC and DO - HI6000","description":"\u003cp\u003eThe HI6000 multiparameter modular system is a totally flexible benchtop meter platform that\u003cbr\u003e\nis customizable to a user’s laboratory measurement and application needs.\u003cbr\u003e\nHanna offers four different measurement modules for pH\/ORP, pH\/ORP\/ISE, DO, and EC.\u003cbr\u003e\nTogether with appropriate sensors, the meter provides quick and reliable measurement\u003cbr\u003e\ndisplayed on the large, 7-inch capacitive touch display. The display supports multi-touch,\u003cbr\u003e\nvideo playback and data plotting.\u003cbr\u003e\nThe meter is supplied with an electrode holder that has a flexible arm. The holder can be\u003cbr\u003e\nmounted quickly and provides secure support for electrodes while taking measurements in\u003cbr\u003e\nsample containers.\u003cbr\u003e\nMeasure\u003cbr\u003e\n• HI6000-1 module choice of measurement unit:\u003cbr\u003e\n• pH - pH, mV\u003cbr\u003e\n• ORP* - mV, Rel.mV\u003cbr\u003e\n• HI6000-2 module choice of measurement unit:\u003cbr\u003e\n• pH - pH, mV\u003cbr\u003e\n• ORP* - mV, Rel.mV\u003cbr\u003e\n• ISE - ppt, ppm, ppb, g\/L, mg\/L, μg\/L, mg\/mL, μg\/mL, M, mol\/L, mmol\/L, %w\/v, user\u003cbr\u003e\ndefined\u003cbr\u003e\n• HI6000-3 module choice of measurement unit:\u003cbr\u003e\n• Conductivity – μS\/cm or mS\/cm,\u003cbr\u003e\n• Resistivity – Ω•cm, kΩ•cm, MΩ•cm,\u003cbr\u003e\n• TDS – ppm, ppt,\u003cbr\u003e\n• Salinity – ppt, PSU, %,\u003c\/p\u003e\n\u003cp\u003e• HI6000-4 module choice of measurement unit:\u003cbr\u003e\n• DO – % Sat, mg\/L, ppm\u003cbr\u003e\n• BOD - ppm, mg\/L,\u003cbr\u003e\n• OUR - ppm, mg\/L\u003cbr\u003e\n• SOUR - ppm, mg\/L\u003cbr\u003e\n• Pressure - mmHg, mbar, kPa, inHg, psi, atm\u003cbr\u003e\n• Application-specific profiles allow quick and direct measurement without the need to\u003cbr\u003e\nupdate the sensor and system settings\u003cbr\u003e\n• Method-specific application reports can be generated\u003cbr\u003e\n• Measurement stability indicator (using the Stability Criteria setting)\u003cbr\u003e\n• Temperature compensation can be Automatic (using integrated temperature sensor) or set\u003cbr\u003e\nmanually\u003cbr\u003e\n• Audible and \/ or alarm messages for measurements outside predefined limits\u003cbr\u003e\n• Non-volatile memory for data storage and settings\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460229489,"sku":"HI6000","price":101958.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6000-Front-4216x4216-216efe98-4e65-4c20-b70a-453d3fe4eedb-scaled.jpg?v=1792646964"},{"product_id":"hi6000-1-ph-orp-module-designed-to-be-used-with-the-hi6000-multiparameter-modular-system","title":"HI6000-1 pH\/ORP Module designed to be used with the HI6000 Multiparameter Modular System","description":"\u003cp\u003eMeasurement\u003cbr\u003e\n• Measure pH or mV with temperature (HI6000-1);\u003cbr\u003e\n• Application-specific profiles allow quick and direct measurement without the need to\u003cbr\u003e\nupdate the sensor and system settings\u003cbr\u003e\n• Active log during measurement\u003cbr\u003e\n• Measurement stability indicator (using the Stability Criteria setting)\u003cbr\u003e\n• Reading modes:\u003cbr\u003e\n• Direct and direct\/autohold\u003cbr\u003e\n• Temperature compensation can be Automatic (using temperature probe) or set manually\u003c\/p\u003e\n\u003cp\u003e•Audible and\/or alarm messages for measurements outside of predefined limits\u003cbr\u003e\n•Galvanic isolation for pH\/ORP measurement\u003cbr\u003e\nCalibration\u003cbr\u003e\n•pH calibration using\u003cbr\u003e\n•Up to five Hanna Instruments pH buffers (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and\u003cbr\u003e\n12.45)\u003cbr\u003e\n•Up to five custom buffers\u003cbr\u003e\n•mV calibration using a single point to calibrate offset.\u003cbr\u003e\n•ISE calibration using up to five nominal standard values (e.g. for ppm: 0.010, 0.100, 1.00,\u003cbr\u003e\n10.0, 100, 1000, 10000 ppm) and\/or up to five custom solutions (user supplied)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6000-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI6000-1 pH\/ORP Module designed to be used with the HI6000 Multiparameter Modular System. - HI6000-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\ncompensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\npoints\u003c\/td\u003e\n\u003ctd\u003eup to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\nbuffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18,\n10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration\npoint\u003c\/td\u003e\n\u003ctd\u003eOffset or point (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential\npoint\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Isopotential\npoint\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e−2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point offset, ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range*\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\n-4.0 to 248.0 °F\n253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\n0.1 °F\n0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C\n±0.4 °F\n±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode\u003c\/td\u003e\n\u003ctd\u003eDirect; Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement data\nMeasurement profile (if enabled)\nStability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nLast calibration date, slope, offset (pH, Rel. mV - ISE\nonly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information\nCalibration point details (pH \u0026amp; ISE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Graph\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nMeasurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Table\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nTable with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI6000-01 (US power plug) is supplied with HI764060 electrode holder; 24 VDC power adapter; USB-C to USB-A cable; quick reference guide and instrument quality certificate.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460262257,"sku":"HI6000-1","price":22588.2,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6000-1-3448x3448-d803e944-e6e3-4465-856f-e402a8e6d00d-scaled.jpg?v=1792646965"},{"product_id":"hi6000-2-ph-orp-ise-module-is-designed-to-be-used-with-the-hi6000-multiparameter-modular-system","title":"HI6000-2 (pH\/ORP\/ISE) module is designed to be used with the HI6000 Multiparameter Modular System","description":"\u003cp\u003eMeasurement\u003cbr\u003e\n• Measure pH, mV, or ISE with temperature (HI6000-2)\u003cbr\u003e\n• Application-specific profiles allow quick and direct measurement without the need to\u003cbr\u003e\nupdate the sensor and system settings\u003cbr\u003e\n• Active log during measurement\u003cbr\u003e\n• Measurement stability indicator (using the Stability Criteria setting)\u003cbr\u003e\n• Reading modes:\u003cbr\u003e\n• Direct and direct\/autohold\u003cbr\u003e\n• Known Addition, Known Subtraction, Analyte Addiiton, Analyte Subtration (HI6000-2)\u003cbr\u003e\n• Temperature compensation can be Automatic (using temperature probe) or set manually\u003c\/p\u003e\n\u003cp\u003e•Audible and\/or alarm messages for measurements outside of predefined limits\u003cbr\u003e\n•Galvanic isolation for pH\/ORP measurement\u003cbr\u003e\nCalibration\u003cbr\u003e\n•pH calibration using\u003cbr\u003e\n•Up to five Hanna Instruments pH buffers (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and\u003cbr\u003e\n12.45)\u003cbr\u003e\n•Up to five custom buffers\u003cbr\u003e\n•mV calibration using a single point to calibrate offset.\u003cbr\u003e\n•ISE calibration using up to five nominal standard values (e.g. for ppm: 0.010, 0.100, 1.00,\u003cbr\u003e\n10.0, 100, 1000, 10000 ppm) and\/or up to five custom solutions (user supplied)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6000-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI6000-1 pH\/ORP Module designed to be used with the HI6000 Multiparameter Modular System. - HI6000-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\ncompensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\npoints\u003c\/td\u003e\n\u003ctd\u003eup to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\nbuffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18,\n10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration\npoint\u003c\/td\u003e\n\u003ctd\u003eOffset or point (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential\npoint\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Isopotential\npoint\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e−2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point offset, ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003e1.0×10-5 to 300.0 ppt (g\/L or\nmg\/mL)\n5.0×10-3 to 1.0×105 ppm\n(mg\/L or µg\/mL)\n1.0 to 5.0×107 ppb (µg\/L)\n1.0×10-7 to 10.0 M (mol\/L)\n1.0×10-4 to 1.0×104 mmol\/L\n1.0×10-6 to 60.0 %w\/v\n5.0×10-7 to 5.0×107 user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions)\n±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration type\u003c\/td\u003e\n\u003ctd\u003eAll standards\nStandard group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Standards\u003c\/td\u003e\n\u003ctd\u003e7 standard solutions available\nfor each concentration unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Custom standards\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Custom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range*\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\n-4.0 to 248.0 °F\n253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\n0.1 °F\n0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C\n±0.4 °F\n±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode\u003c\/td\u003e\n\u003ctd\u003eDirect; Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement data\nMeasurement profile (if enabled)\nStability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nLast calibration date, slope, offset (pH, Rel. mV - ISE\nonly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information\nCalibration point details (pH \u0026amp; ISE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Graph\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nMeasurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Table\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nTable with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI6000-02 (EU power plug) is supplied with HI764060\u003cbr\u003e\nelectrode holder; 24 VDC power adapter; USB-C to USB-A cable; quick reference guide and\u003cbr\u003e\ninstrument quality certificate.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460589937,"sku":"HI6000-2","price":37647.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6000-2-3448x3448-3a07ca94-9c25-4288-8092-e3ab26c79ca0-scaled.jpg?v=1792646966"},{"product_id":"hi6000-3-conductivity-module","title":"HI6000-3 Conductivity Module","description":"\u003cp\u003eMeasurement\u003cbr\u003e\n• Measure μS\/cm, mS\/cm (Conductivity); Ω·cm, kΩ·cm, MΩ·cm (Resistivity); ppm, ppt (TDS);\u003cbr\u003e\nppt, PSU, % (Salinity) with temperature\u003cbr\u003e\n• Application-specific profiles allow quick and direct measurement without the need to\u003cbr\u003e\nupdate the sensor and system settings\u003cbr\u003e\n• Active log during measurement\u003cbr\u003e\n• Measurement stability indicator (using the Stability Criteria setting)\u003cbr\u003e\n• Reading modes: direct and direct\/autohold\u003cbr\u003e\n• Temperature compensation can be Automatic or set manually\u003cbr\u003e\n• Audible and\/or alarm messages for measurements outside of predefined limits\u003cbr\u003e\n• Galvanic isolation for conductivity measurement\u003c\/p\u003e\n\u003cp\u003eCalibration\u003cbr\u003e\n• Conductivity calibration using:\u003cbr\u003e\n• Up to four Hanna Instruments standards – 84 μS\/cm, 1413 μS\/cm, 5000 μS\/cm, 12880\u003cbr\u003e\nμS\/cm, 80000 μS\/cm and 111800 μS\/cm – for cell factor determination; and 0 μS\/cm for\u003cbr\u003e\nOffset\u003cbr\u003e\n• Up to four custom standards\u003cbr\u003e\n• Salinity (%) calibration using 100% salinity standard\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6000-3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI6000-3 Conductivity Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm;\n100.0 to 999.9 μS\/cm; 1.000 to 9.999 mS\/cm;\n10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm;\n0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Cell Constant\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.0000 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Points\u003c\/td\u003e\n\u003ctd\u003eSingle Up to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Solutions\u003c\/td\u003e\n\u003ctd\u003e84 μS\/cm\n1413 μS\/cm\n5000 μS\/cm\n12880 μS\/cm\n80000 μS\/cm\n111800 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eLinear\nNatural\nStandard\nDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Reference Temperature\u003c\/td\u003e\n\u003ctd\u003e5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Temperature Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm;\n10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm;\n1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm;\n0.01 MΩ·cm; 0.1 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω•cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm;\n100.0 to 999.9 ppm; 1.000 to 9.999 ppt;\n10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with\n1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU (Practical Salinity Scale)\n0.00 to 80.00 ppt (Natural Sea Water)\n0.0 to 400.0 % (Percent Scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\n0.01 ppt\n0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point, using 100 % salinity calibration solution (% scale\nonly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range*\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C\n−4.0 to 248.0 °F\n253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\n0.1 °F\n0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C\n±0.4 °F\n±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calilbration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode\u003c\/td\u003e\n\u003ctd\u003eDirect\nDirect\/Autohold\nDirect\/USP (Conductivity only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eView Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement data\nMeasurement profile (if enabled)\nStability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eView Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nLast calibration date and offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eView Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information\nCalibration point details (conductivity \u0026amp; salinity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eView Graph\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nMeasurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eView Table\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nTable with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460622705,"sku":"HI6000-3","price":37647.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6000-3-3448x3448-752681ed-37ef-4b2e-9dd8-c2e653e7ee5c.jpg?v=1792646966"},{"product_id":"hi6000-4-dissolved-oxygen-module","title":"HI6000-4 Dissolved Oxygen Module","description":"\u003cp\u003eMeasurement\u003cbr\u003e\n• Measure %Sat, mg\/L, ppm (DO);\u003cbr\u003e\n• mg\/L, ppm (BOD), mg\/L (OUR), ppm, mg\/L (SOUR)\u003cbr\u003e\n• Application-specific profiles allow quick and direct measurement without the need to\u003cbr\u003e\nupdate the sensor and system settings\u003c\/p\u003e\n\u003cp\u003e•Active log during measurement\u003cbr\u003e\n•Measurement stability indicator (using the Stability Criteria setting)\u003cbr\u003e\n•Reading modes: direct and direct\/autohold; BOD, OUR, SOUR\u003cbr\u003e\n•Temperature compensation can be Automatic or set manually\u003cbr\u003e\n•Audible and\/or alarm messages for measurements outside of predefined limits\u003cbr\u003e\n•Galvanic isolation for measurement\u003c\/p\u003e\n\u003cp\u003eCalibration\u003cbr\u003e\n•One or two points automatic calibration at 100.0 % (8.26 mg\/L) and 0.0 % (0.00 mg\/L)\u003cbr\u003e\n•One point manual calibration using a valued entered by the user\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6000-4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI6000-4 Dissolved Oxygen Module\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 600.0 % saturation; 0.00 to 90.00 mg\/L (ppm)\nconcentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 % saturation; 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Accuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric pressure Range\u003c\/td\u003e\n\u003ctd\u003e450.0 to 850.0 mmHg \/ 600.0 to 1133.2 mbar \/ 60.00\nto 113.32 kPa \/ 17.72 to 33.46 inHg \/\n8.702 to 16.436 psi \/ 0.5921 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mmHg \/ 0.1 mBar \/ 0.01 kPa \/ 0.01 inHg \/ 0.001 psi \/ 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from the calibration point;\n±3 mmHg ±1, least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBarometric pressure Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (meter-integrated barometer) or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range*\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003eRefer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO calibration\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 100.0 % (8.26 mg\/L) and 0.0 %\n(0.00 mg\/L) Automatic;\nManual (user entered value in % saturation, mg\/L, or\nppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature user calibration\u003c\/td\u003e\n\u003ctd\u003e1 point, configurable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity compensation\u003c\/td\u003e\n\u003ctd\u003eManual; 0.00 to 45.00 psu or ppt; 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460655473,"sku":"HI6000-4","price":37647.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6000-4-3448x3448-3536c873-0e72-4bca-88ce-27311fc51575.jpg?v=1792646967"},{"product_id":"hi6553-02-ph-orp-ise-and-ec-tds-and-do-benchtop-meter-starter-kit","title":"HI6553-02 pH\/ORP\/ISE and EC\/TDS and DO Benchtop Meter Starter Kit","description":"\u003cp\u003eHI6553-02 (EU power plug) is supplied with HI6000 housing unit; HI6000-2 pH\/ORP\/ISE hardware module (installed); HI6000-3 EC hardware module (installed); HI6000-4 DO hardware module (installed); HI1131B pH electrode; HI7662-TW temperature probe; HI7631233 EC \u0026amp; resistivity probe; HI7641133 optical DO probe; pH 4.01 buffer solution, 2 sachets; pH 7.01 buffer solution, 2 sachets; pH 10.01 buffer solution, 2 sachets; electrode cleaning solution, 2 sachets; pH \u0026amp; ORP electrode storage solution (25 mL); 3.5M KCl electrolyte solution (30 mL); capillary pipette, 1 piece; 1413 μS\/cm standard solution, 2 sachets; 5000 μS\/cm standard solution, 2 sachets; 12880 μS\/cm standard solution, 2 sachets; Electrode rinse solution, 2 sachets; DO Smart Cap with O-ring, 1 pc. of each; calibration\/storage vessel, 1 piece; Lens cleaning wipe, 1 piece; syringe and sachet with silicone grease, 1 piece of each; electrode holder with base plate, screw, cable holder clip (requires mounting), adapter (attached); 24 VDC power adapter; USB-C to USB-A cable; meter quick reference guide; hardware modules quick reference guides and quality certificates; Smart Cap, probes, and meter quality certificates.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003cthead style=\"color: #292f36;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"font-weight: bold;\"\u003eSpecification Name\u003c\/th\u003e\n\u003cth style=\"font-weight: bold;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI6553-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; - 2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustom Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption to select from eight standard buffers and user-defined custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirst Calibration Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOffset or Point (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsopotential Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point offset, ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯5\u003c\/sup\u003e to 300.0 ppt (g\/L or mg\/mL)\n5.0×10\u003csup style=\"font-weight: 500;\"\u003e¯3\u003c\/sup\u003e to 1.0×10\u003csup style=\"font-weight: 500;\"\u003e5\u003c\/sup\u003e ppm (mg\/L or µg\/mL)\n1.0 to 5.0×10\u003csup style=\"font-weight: 500;\"\u003e7\u003c\/sup\u003e ppb (µg\/L)\n1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯7\u003c\/sup\u003e to 10.0 M (mol\/L)\n1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯4\u003c\/sup\u003e to 1.0×10\u003csup style=\"font-weight: 500;\"\u003e4\u003c\/sup\u003e mmol\/L\n1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯6\u003c\/sup\u003e to 60.0 %w\/v\n5.0×10\u003csup style=\"font-weight: 500;\"\u003e¯7\u003c\/sup\u003e to 5.0×10\u003csup style=\"font-weight: 500;\"\u003e7\u003c\/sup\u003e user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAll Standards; Standard Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 standard solutions available for each concentration unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Custom Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Custom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Cell Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.0000 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle; Up to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Calibration Solutions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84 μS\/cm; 1413 μS\/cm; 5000 μS\/cm; 12880 μS\/cm; 80000 μS\/cm; 111800 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω•cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU; 0.01 ppt; 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 point, using 100 % salinity calibration solution (% scale only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\n\u0026gt; 0.00 to 45.00 PSU or ppt\n\u0026gt; 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Range (HI7641133 optical DO probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0 % saturation; 0.00 to 90.00 mg\/L (ppm) concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 % saturation; 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 100.0 % (8.26 mg\/L) and 0.0 % (0.00 mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Manual (user entered value in % saturation, mg\/L, or ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450.0 to 850.0 mmHg; 600.0 to 1133.2 mbar; 60.00 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from calibration point; ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic (meter-integrated barometer); Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor pH and conductivity: ±0.2 °C; ±0.4 °F; ±0.2 K\nFor DO: Refer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor pH and DO: Automatic; Manual\nFor Conductivity: Linear; Natural; Standard; Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor Conductivity: 0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect\nDirect\/Autohold\nFor ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction\nFor Conductivity: Direct\/USP\nFor DO Only: OUR, SOUR, BOD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeasurement data; Measurement profile (if enabled); Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSimple GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nFor pH: Last calibration date, slope, offset (pH, Rel. mV - ISE only)\nFor Conductivity: Last calibration date and offset\nFor DO: Last calibration date, offset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimple GLP Information; Calibration point details (pH, ISE, conductivity, salinity, and DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGraph View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic view information; Measurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTable View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic view information; Table with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading Stability Criteria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading Sampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Manual; Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Number of Records\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,000 maximum per file and stores at least 1,000,000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Automatic Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Sample ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncremental Mode; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Export Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.CSV file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity USB-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 ports\nkeyboard and\/or printer input\nUSB Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity USB-C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 port\nPC Connectivity and USB-C Type Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFTP; Web Server (Log transfer and download); Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity RS232\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Reminder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDaily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240 VAC to 24 VDC 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C \/ 32 to 122 °F \/ 273 to 323 K maximum 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 \")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.05 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460852081,"sku":"HI6553-02","price":253874.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6553-White__49705.jpg?v=1792646970"},{"product_id":"edge-multiparameter-ph-meter-230v-hi2020","title":"edge® Multiparameter pH Meter, 230V - HI2020-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eedge® is packed with many cutting edge features to ensure accuracy and usability.\u003c\/p\u003e\n\u003ch5\u003eDigital Electrodes\u003c\/h5\u003e\n\u003cp\u003eedge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.\u003c\/p\u003e\n\u003ch5\u003eSensor Check\u003c\/h5\u003e\n\u003cp\u003eWhen used with Hanna’s pH electrodes equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. During calibration, Sensor Check checks the state of the junction. The reference junction is also evaluated and reported on the display.\u003c\/p\u003e\n\u003ch5\u003e3.5 mm Probe Input\u003c\/h5\u003e\n\u003cp\u003ePlugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.\u003c\/p\u003e\n\u003ch5\u003eWall Mount\u003c\/h5\u003e\n\u003cp\u003eUsing the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.\u003c\/p\u003e\n\u003ch5\u003eCradle and Electrode Holder\u003c\/h5\u003e\n\u003cp\u003eedge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.\u003c\/p\u003e\n\u003ch5\u003eTwo USB Ports\u003c\/h5\u003e\n\u003cp\u003eedge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.\u003c\/p\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cp\u003eedge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.\u003c\/p\u003e\n\u003ch5\u003eTwo Operating Modes\u003c\/h5\u003e\n\u003cp\u003eedge can be used in Extended or Basic Operating Modes. Extended Mode enables all features available while the Basic Mode reduces the amount of features to a very simple operation. For example, in extended mode edge offers 5 point calibration with 2 custom buffers while in basic mode calibration can only be performed to 3 points with 5 preprogrammed buffers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/45ms0xpvk5?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/8c55539d67ea1d24de589d4f7ab0d40faf95a394.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI2020-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e® Multiparameter pH Meter - HI2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 pH, 0.01 pH, 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.002 pH, ±0.01 pH, ±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eGlass and reference junction diagnostics ( HI 11311 \u0026amp; HI 12301 only), out of calibration range , probe condition, response time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm, 30.0 to 299.9 µS\/cm, 300 to 2999 µS\/cm, 3.00 to 29.99 mS\/cm, 30.0 to 200.0 mS\/cm, up to 500.0 mS\/cm (absolute EC)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm, 0.1 µS\/cm, 1 µS\/cm, 0.01 mS\/cm, 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point offset calibration (0.00 µS\/cm in air), 1 point slope calibration in EC standard 84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm and 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 ppm (mg\/L), 15.0 to 149.9 ppm (mg\/L), 150 to 1499 ppm (mg\/L), 1.50 to 14.99 g\/L, 15.0 to 100.0 g\/L, up to 400.0 g\/L (absolute TDS)**, with 0.80 conversion factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g\/L, 0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0% NaCl***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point with HI 7037L 100% NaCl sea water standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e2.00 to 42.00 PSU***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 80.0 g\/L***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 ppm (mg\/L), 0.0 up to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 digit, ±1.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eone or two points at 0% (HI 7040 solution) and 100% (in air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC: 0 to 50 ºC; 32.0 to 122.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (with 1 g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e-500 to 4000 m (with 100 m resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 ºC, -4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C, ±0.9 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI11310 pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eManual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 1000*** records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 micro USB port for charging and PC connectivity, 1 USB port for storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eBuilt-in rechargeable battery with up to 8 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7mm (8” x 5.5” x 0.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g (8.82 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI2020 pH kit includes: HI11310 glass body, refillable pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI2020-01\" target=\"_blank\" rel=\"noopener\"\u003e® Multiparameter pH Meter - HI2020\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461736817,"sku":"HI2020-02","price":69984.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sides-png-700_C3_97700.png?v=1792646983"}],"url":"https:\/\/hannainst.in\/collections\/multiparameter-benchtop-meters.oembed","provider":"hanna","version":"1.0","type":"link"}