{"title":"Testers – Multiparameter Testers","description":"","products":[{"product_id":"combo-ph-conductivity-tds-tester-low-range-hi98129","title":"Combo pH\/Conductivity\/TDS Tester (Low Range) - HI98129","description":"\u003cp\u003eThe HI98129 is a highly accurate, waterproof pH meter that can also measure EC\/TDS in the low range (0 to 3999 µS\/cm EC\/ 0 to 2000 ppm TDS) and temperature. This floating, waterproof combination tester has an easy to read, LCD and an automatic shut-off. In addition, pH and EC\/TDS readings are automatically temperature compensated (ATC) to prevent temperature-related variations in your measurements. For EC\/TDS readings, the EC\/TDS conversion factor (CONV) is selectable by the user, as well as the temperature compensation coefficient β (BETA).\u003c\/p\u003e\n\u003ch4\u003eReplaceable pH Electrode Cartridge\u003c\/h4\u003e\n\u003cp\u003eThe HI98129 tester features an easy to replace pH electrode cartridge with an extendable cloth junction. The extendable cloth junction helps increase electrode life and the replaceable pH cartridge means that this tester does not need to be thrown away when the pH sensor is exhausted. Also, the sturdy, snap-in connector means there are no pins to bend or break!\u003c\/p\u003e\n\u003ch4\u003eHigh Accuracy EC\/TDS Graphite Probe\u003c\/h4\u003e\n\u003cp\u003eThe graphite conductivity probe provides greater accuracy because it cannot be contaminated by salt deposits in the solution. The exposed temperature sensor provides fast response times and guarantees highly accurate temperature compensated readings.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e3 sensors in a single meter\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH electrode with extractable junction\u003c\/p\u003e\n\u003cp\u003eAmperometric EC\/TDS sensor\u003c\/p\u003e\n\u003cp\u003eExposed temperature probe for faster EC\/TDS readings\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWaterproof\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDesigned to float if accidently dropped in sample\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWide pH Range\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH range is from 0.00 to 14.00 pH\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSelectable EC to TDS conversion factor\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eChoice of either a 0.45 or 1.0 conversion factor\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAutomatic Temperature Compensation\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAll readings are compensated for variations in temperature\u003c\/p\u003e\n\u003cp\u003eTemperature displayed in ℃ or ℉ along with pH, EC or TDS reading\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eStability indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHOLD button\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eFreezes reading on the display to allow recording of measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBEPS (Battery Error Prevention System\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBattery % level at startup\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAuto-off feature automatically shuts off meter after 8 minutes of non-use to maximize battery life\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCombo pH\/Conductivity\/TDS Tester (Low Range) - HI98129\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 1382 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic with β adjustable from 0.0 to 2.4% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 (replaceable; included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 100 hours of continuous use, auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98129 is supplied with HI73127 pH electrode and HI73128 electrode removal tool, batteries (4 x 1.5V) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98129\" target=\"_blank\" rel=\"noopener\"\u003eCombo pH\/Conductivity\/TDS Tester (Low Range) - HI98129\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871262245233,"sku":"HI98129","price":19524.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98129-ppm_1.jpg?v=1792645989"},{"product_id":"groline-hydroponic-waterproof-pocket-ph-ec-tds-temperature-tester-hi98131","title":"GroLine Hydroponic Waterproof Pocket pH\/EC\/TDS\/Temperature Tester - HI98131","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI98131 GroLine tester features a large multi level LCD which displays both pH, EC or TDS and temperature readings simultaneously. The pH readings are displayed with a 0.01 resolution and with an accuracy of ±0.05 pH, while the EC and TDS readings are displayed with a 0.01 mS\/cm and 10 ppm (mg\/L) resolution and 2% full scale accuracy. The EC range of the HI98131 is from 0.01 to 6.00 mS\/cm and TDS is from 0 to 3000 ppm using a 0.5 conversion factor. The HI98131 also offers the option to use a 0.7 (700 ppm) EC to TDS conversion factor. An exposed temperature sensor allows for rapid temperature compensated measurements of EC and TDS. The LCD screen has indicators for calibration status and stability. The battery percent level is displayed at start up alerting the user to the remaining battery power that is available. The HI98131 is a versatile pocket meter designed for hydroponics, greenhouse and agriculture applications.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98131-gro-line-combo-removable-probe.jpg\" alt=\"groline hydroponics ph ec ppm meter\" width=\"1000\" height=\"1000\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSimplified one button calibration\u003c\/h5\u003e\n\u003cp\u003eOne or two point pH calibration is automatic to a pre-programmed buffer set (4.01, 7.01 and 10.01) or single point pH and EC calibration with the Hanna Quick Cal calibration solution. To perform a quick cal calibration, simply press and hold the left power\/mode button while in measurement mode for three seconds and let go to enter calibration mode. Once both pH and EC are calibrated \"CAL OK\" is displayed and the meter returns to measurement mode.\u003c\/p\u003e\n\u003ch5\u003eHI73127 Replaceable pH electrode\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003eThe HI99131 is supplied with the HI73127 replaceable pH electrode. This electrode features an extractable junction that can be pulled 1\/8\" out to clear any clogging that results in drifting and erratic readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFeatures at-a-glance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003e3 sensors in a single meter\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH electrode with extractable junction\u003c\/p\u003e\n\u003cp\u003eAmperometric EC\/TDS sensor\u003c\/p\u003e\n\u003cp\u003eExposed temperature probe for faster EC\/TDS readings\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWaterproof\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eDesigned to withstand the humidity of a growing environment\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eWide pH Range\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003epH range is from 0.00 to 14.00 pH\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eSelectable EC to TDS conversion factor\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eChoice of either a 0.5 or 0.7 conversion factor\u003c\/p\u003e\n\u003cp\u003e0.5 (500 CF) conversion factor is for an EC reading of 1000 μS\/cm = 500 ppm\u003c\/p\u003e\n\u003cp\u003e0.7 (700 CF) conversion factor is for an EC reading of 1000 μS\/cm = 700 ppm\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAutomatic Temperature Compensation\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eAll readings are compensated for variations in temperature\u003c\/p\u003e\n\u003cp\u003eTemperature displayed in ℃ or ℉ along with pH, EC or TDS reading\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eStability indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter displays a clock tag that will disappear when the reading has achieved stability\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eHOLD button\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eFreezes reading on the display to allow recording of measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBEPS (Battery Error Prevention System\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eMeter will automatically shut off if there is not enough power to get an accurate measurement\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eBattery % level at startup\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eLow Battery Indicator\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eWhen the level is below 5%, the battery symbol on the LCD blinks to indicate a low battery condition.\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003e\u003cstrong\u003eAuto-off\u003c\/strong\u003e\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003eSelectable time before meter will automatically shuts off to conserve battery life. Options are after 8 minutes, 60 minutes , or disabled.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eGroLine Hydroponic Waterproof Pocket pH\/EC\/TDS\/Temperature Tester - HI98131\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points using standard buffers (pH 4.01, 7.01,10.01); one point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at 1.41 mS\/cm or 5.00 mS\/cm; one point calibration using quick calibration solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3000 ppm (500 CF); 0 to 3999 ppm (700 CF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e10 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003edone through conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eEC\/TDS: automatic with β set at 1.9%\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5 (500 ppm) or 0.7 (700 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCell Type\u003c\/td\u003e\n\u003ctd\u003eamperometric two pole\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eauto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98131 is supplied with HI73127 pH electrode, HI73128 electrode removal tool, batteries (4), instructions and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98131\" target=\"_blank\" rel=\"noopener\"\u003eGroLine Hydroponic Waterproof Pocket pH\/EC\/TDS\/Temperature Tester - HI98131\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871415304561,"sku":"HI98131","price":21563.0,"currency_code":"INR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98131_front_2.jpg?v=1792646548"},{"product_id":"combo-ph-conductivity-tds-tester-high-range-hi98130","title":"Combo pH\/Conductivity\/TDS Tester (High Range) - HI98130","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003epH electrode with extractable cloth junction\u003c\/p\u003e\n\u003cp\u003eAmperometric EC\/TDS sensor\u003c\/p\u003e\n\u003cp\u003eExposed temperature probe for faster EC\/TDS readings\u003c\/p\u003e\n\u003cp\u003eCompact, waterproof design fits right in your pocket so you can take it anywhere\u003c\/p\u003e\n\u003cp\u003eWaterproof and designed to float in water\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eBEPS (Battery Error Prevention System with three user controlled automatic shutoff settings\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCombo pH\/Conductivity\/TDS Tester (High Range) - HI98130\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, at one or two points with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point at: 6.44 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic with β adjustable from 0.0 to 2.4% \/ °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127 (replaceable; included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4) \/ approx. 100 hours of continuous use, auto-off after 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e163 x 40 x 26 mm (6.4 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e100 g (3.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98130 is supplied with HI73127 pH electrode and HI73128 electrode removal tool, batteries (4 x 1.5V) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98130\" target=\"_blank\" rel=\"noopener\"\u003eCombo pH\/Conductivity\/TDS Tester (High Range) - HI98130\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451840881,"sku":"HI98130","price":19524.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98130-2016.jpg?v=1792646888"},{"product_id":"pool-line-combo-ph-ec-tds-tester-high-range-hi981304","title":"Pool Line Combo pH\/EC\/TDS Tester (High Range) - HI981304","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eAmperometric EC\/TDS sensor, pH electrode, and temperature probe in one meter\u003c\/p\u003e\n\u003cp\u003eHigh accuracy EC\/TDS graphite probe reduces polarization effects and does not oxidize\u003c\/p\u003e\n\u003cp\u003eSelectable EC to TDS conversion factor of 0.45 or 1.0\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation coefficient β (BETA), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eHOLD button for easier measurement recording\u003c\/p\u003e\n\u003cp\u003eBattery Error Prevention System (BEPS) with low battery indicator\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI981304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Combo pH\/EC\/TDS Tester (High Range) - HI981304\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or pH 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 20.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point calibration at 12.88 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one-point calibration at 6.44 ppt using 0.5 conversion factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic EC\/TDS: ß=0.0 to 2.4% \/ ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.45 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0 °C (32.0 to 140.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (±1.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI73127\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eAfter 8 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V (4)\/ Approximately 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e171 x 41 x 26 mm (6.7 x 1.6 x 1.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e93 g (3.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI981304 is supplied with HI700044 pH 4.01 buffer solution, 20 mL sachet (1 pc.), HI700074 pH 7.01 buffer solution, 20 mL sachet (1 pc.), HI7003004 Storage solution for pH \u0026amp; ORP electrodes, 20 mL sachet (1 pc.), HI700304 12880 µS\/cm conductivity standard, 20 mL sachet (1 pc.), HI700384 6.44 ppt TDS standard, 20 mL sachet (1 pc.), HI7006014pH \u0026amp; ORP electrode cleaning solution, 20 mL sachet (1 pc.), HI73127 pH electrode, HI73128 Electrode removal tool, Storage \/ Protection cap, 1.5V batteries (4 pcs.), Instrument quality certificate, and Instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI981304\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Combo pH\/EC\/TDS Tester (High Range) - HI981304\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871451906417,"sku":"HI981304","price":26357.4,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi981304.jpg?v=1792646889"}],"url":"https:\/\/hannainst.in\/collections\/multiparameter-testers-testers.oembed","provider":"hanna","version":"1.0","type":"link"}