{"title":"New Launch","description":"\u003cp\u003eProducts shown on the New Launch page (\/pages\/new-launch). Add or remove products here.\u003c\/p\u003e","products":[{"product_id":"dual-channel-universal-process-controller-for-industrial-applications-hi520-controller-with-3-relays-and-2-analog-outputs","title":"Dual-Channel Universal Process Controller for Industrial Applications - HI520-controller with 3 relays and 2 analog outputs - HI520-0320","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eDescription:\u003c\/h2\u003e\n\u003cp\u003eHI520 is an advanced process controller that can be configured for applications requiring monitoring and\/or control of four main water-analysis parameters: pH, ORP, Conductivity, and Dissolved Oxygen. This controller features a digital probe input(s) that automatically detects and updates the controller with the parameter that it measures.\u003c\/p\u003e\n\u003cp\u003eHI520 is Hanna's first dual-input process controller that accepts virtually any combination of compatible probes. Designed to adapt to unique process control requirements, users have the option to enable or disable each channel independently.\u003c\/p\u003e\n\u003cp\u003eAdditionally, HI520 introduces enhanced industrial control by operating a control-loop system whereby users have the option to run channel control either independently or configure to be triggered sequentially upon reaching the other channel's set point(s) (1, 2, or both). The device operates a logical channel with built-in mathematical functions. This function is intended for when the controller works as an analyzer for monitoring high\/low parameter levels between two identical inputs with identical measuring configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI510_HI520_1p1_0323_Page_02_Image_0001.jpg\" alt=\"HI520\" width=\"448\" height=\"539\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eControl Modes\u003c\/h4\u003e\n\u003cp\u003eSet points for control operations can be configured to be on\/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.\u003c\/p\u003e\n\u003ch4\u003eHold Function\u003c\/h4\u003e\n\u003cp\u003eHold can also be triggered manually and by using and external digital input for disabling control mode when performing maintenance.\u003c\/p\u003e\n\u003ch4\u003eConfigurable Alarm System\u003c\/h4\u003e\n\u003cp\u003eConfigurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.\u003c\/p\u003e\n\u003ch4\u003eAuto-cleaning cycle\u003c\/h4\u003e\n\u003cp\u003eThe cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.\u003c\/p\u003e\n\u003ch4\u003eRelays\u003c\/h4\u003e\n\u003cp\u003eAvailable with up to five control and one alarm electromechanical relays.\u003c\/p\u003e\n\u003ch4\u003eAnalog Outputs\u003c\/h4\u003e\n\u003cp\u003eUp to four galvanically isolated analog outputs for control of pumps and valves.\u003c\/p\u003e\n\u003ch4\u003eDigital RS485 Output\u003c\/h4\u003e\n\u003cp\u003eCan daisy-chain up to 32 devices to a remote monitoring system.\u003c\/p\u003e\n\u003ch4\u003eDigital Inputs\u003c\/h4\u003e\n\u003cp\u003eTwo digital inputs available for modes including disabling, cleaning and placing the controller into hold status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/aHI510_controller_hold.png\" alt=\"HI520\" width=\"300\" height=\"186\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLarge LCD\u003c\/h4\u003e\n\u003cp\u003eThe LCD displays measurement information along with indicators of potential problems. The DIAG key then provides details of the issue.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bHI510_controller_logging.png\" alt=\"HI520\" width=\"300\" height=\"186\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eData-logging\u003c\/h4\u003e\n\u003cp\u003eStore info at selectable intervals along with relay control settings and calibrations data. Up to 100 lots, each holding 8600 records. Transfer to a flash drive as a .csv file using the USB Type-C port.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/cHI510_controller_diagnostic.png\" alt=\"HI520\" width=\"300\" height=\"186\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp Button\u003c\/h4\u003e\n\u003cp\u003eUsing the help and diagnostic button (? DIAG) will provide information related to errors or in setup mode, information about settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI520-0320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eDual-Channel Universal Process Controller for Industrial Applications - HI520-controller with 3 relays and 2 analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD, 128 x 64 pixel B\/W with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e2 independent, galvanically isolated inputs (conﬁgurable for Hold \u0026amp; Cleaning functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn state\u003c\/td\u003e\n\u003ctd\u003e5 to 24 Vdc, low or high level active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 or 4 independent, galvanically isolated outputs 0 – 22 mA conﬁgurable as: 0 – 20 mA;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 – 20 mA 22 mA as alarm signal, conﬁgurable option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Communication\u003c\/td\u003e\n\u003ctd\u003eRS485 serial port - Remote monitoring and control USB-C port - Retrieve log ﬁles and ﬁrmware upgrading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003eUp to 5 relays (independently conﬁgurable for process variables, Hold \u0026amp; Cleaning functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromechanical relay SPDT and SPST contact outputs 5A – 250 Vac; 5A – 30 Vdc (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protected\u003c\/td\u003e\n\u003ctd\u003e5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay for All Measurement Alarms\u003c\/td\u003e\n\u003ctd\u003eElectromechanical relay SPDT contact output 5A – 250 Vac; 5A – 30 Vdc (resistive load) Fuse protected: 5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003eInterval log, up to 100 ﬁles, maximum 8600 records on each stored ﬁle. When the maximum limit of 100 stored ﬁles is reached, the most recent ﬁle will automatically erase the oldest one.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent log, maximum 100 records. When the maximum limit is reached, the last record overwrites the oldest one.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 – 240 Vac ±10%; 50\/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure*\u003c\/td\u003e\n\u003ctd\u003eSingle case ½ DIN, type 4X, IP65 ingress protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.6 kg (3.5 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth: 144.0 mm (5.7 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e144.0 mm (5.7 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e151.3 mm (6.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI520-0320\" target=\"_blank\" rel=\"noopener\"\u003eDual-Channel Universal Process Controller for Industrial Applications - HI520-controller with 3 relays and 2 analog outputs\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871313494385,"sku":"HI520-0320","price":150950.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/520_open_fuse-panel-900x900-e9c0b20e-2680-429b-ac5b-ab5a4217a362.jpg?v=1792646127"},{"product_id":"dual-channel-universal-process-controller-for-industrial-applications-hi520-controller-with-5-relays-and-4-analog-outputs","title":"Dual-Channel Universal Process Controller for Industrial Applications - HI520-controller with 5 relays and 4 analog outputs - HI520-0540","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eDescription:\u003c\/h2\u003e\n\u003cp\u003eHI520 is an advanced process controller that can be configured for applications requiring monitoring and\/or control of four main water-analysis parameters: pH, ORP, Conductivity, and Dissolved Oxygen. This controller features a digital probe input(s) that automatically detects and updates the controller with the parameter that it measures.\u003c\/p\u003e\n\u003cp\u003eHI520 is Hanna's first dual-input process controller that accepts virtually any combination of compatible probes. Designed to adapt to unique process control requirements, users have the option to enable or disable each channel independently.\u003c\/p\u003e\n\u003cp\u003eAdditionally, HI520 introduces enhanced industrial control by operating a control-loop system whereby users have the option to run channel control either independently or configure to be triggered sequentially upon reaching the other channel's set point(s) (1, 2, or both). The device operates a logical channel with built-in mathematical functions. This function is intended for when the controller works as an analyzer for monitoring high\/low parameter levels between two identical inputs with identical measuring configurations.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI510_HI520_1p1_0323_Page_02_Image_0001.jpg\" alt=\"HI520\" width=\"448\" height=\"539\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eControl Modes\u003c\/h4\u003e\n\u003cp\u003eSet points for control operations can be configured to be on\/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.\u003c\/p\u003e\n\u003ch4\u003eHold Function\u003c\/h4\u003e\n\u003cp\u003eHold can also be triggered manually and by using and external digital input for disabling control mode when performing maintenance.\u003c\/p\u003e\n\u003ch4\u003eConfigurable Alarm System\u003c\/h4\u003e\n\u003cp\u003eConfigurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.\u003c\/p\u003e\n\u003ch4\u003eAuto-cleaning cycle\u003c\/h4\u003e\n\u003cp\u003eThe cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.\u003c\/p\u003e\n\u003ch4\u003eRelays\u003c\/h4\u003e\n\u003cp\u003eAvailable with up to five control and one alarm electromechanical relays.\u003c\/p\u003e\n\u003ch4\u003eAnalog Outputs\u003c\/h4\u003e\n\u003cp\u003eUp to four galvanically isolated analog outputs for control of pumps and valves.\u003c\/p\u003e\n\u003ch4\u003eDigital RS485 Output\u003c\/h4\u003e\n\u003cp\u003eCan daisy-chain up to 32 devices to a remote monitoring system.\u003c\/p\u003e\n\u003ch4\u003eDigital Inputs\u003c\/h4\u003e\n\u003cp\u003eTwo digital inputs available for modes including disabling, cleaning and placing the controller into hold status.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/aHI510_controller_hold.png\" alt=\"HI520\" width=\"300\" height=\"186\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLarge LCD\u003c\/h4\u003e\n\u003cp\u003eThe LCD displays measurement information along with indicators of potential problems. The DIAG key then provides details of the issue.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bHI510_controller_logging.png\" alt=\"HI520\" width=\"300\" height=\"186\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eData-logging\u003c\/h4\u003e\n\u003cp\u003eStore info at selectable intervals along with relay control settings and calibrations data. Up to 100 lots, each holding 8600 records. Transfer to a flash drive as a .csv file using the USB Type-C port.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/cHI510_controller_diagnostic.png\" alt=\"HI520\" width=\"300\" height=\"186\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp Button\u003c\/h4\u003e\n\u003cp\u003eUsing the help and diagnostic button (? DIAG) will provide information related to errors or in setup mode, information about settings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI520-0540\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eDual-Channel Universal Process Controller for Industrial Applications - HI520-controller with 5 relays and 4 analog outputs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChannels\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD, 128 x 64 pixel B\/W with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Inputs\u003c\/td\u003e\n\u003ctd\u003e2 independent, galvanically isolated inputs (conﬁgurable for Hold \u0026amp; Cleaning functions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOn state\u003c\/td\u003e\n\u003ctd\u003e5 to 24 Vdc, low or high level active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Outputs\u003c\/td\u003e\n\u003ctd\u003e2 or 4 independent, galvanically isolated outputs 0 – 22 mA conﬁgurable as: 0 – 20 mA;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e4 – 20 mA 22 mA as alarm signal, conﬁgurable option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Communication\u003c\/td\u003e\n\u003ctd\u003eRS485 serial port - Remote monitoring and control USB-C port - Retrieve log ﬁles and ﬁrmware upgrading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelays\u003c\/td\u003e\n\u003ctd\u003eUp to 5 relays (independently conﬁgurable for process variables, Hold \u0026amp; Cleaning functions\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectromechanical relay SPDT and SPST contact outputs 5A – 250 Vac; 5A – 30 Vdc (resistive load)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFuse protected\u003c\/td\u003e\n\u003ctd\u003e5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay for All Measurement Alarms\u003c\/td\u003e\n\u003ctd\u003eElectromechanical relay SPDT contact output 5A – 250 Vac; 5A – 30 Vdc (resistive load) Fuse protected: 5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Logging\u003c\/td\u003e\n\u003ctd\u003eInterval log, up to 100 ﬁles, maximum 8600 records on each stored ﬁle. When the maximum limit of 100 stored ﬁles is reached, the most recent ﬁle will automatically erase the oldest one.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEvent log, maximum 100 records. When the maximum limit is reached, the last record overwrites the oldest one.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 – 240 Vac ±10%; 50\/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure*\u003c\/td\u003e\n\u003ctd\u003eSingle case ½ DIN, type 4X, IP65 ingress protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.6 kg (3.5 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth: 144.0 mm (5.7 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHeight\u003c\/td\u003e\n\u003ctd\u003e144.0 mm (5.7 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDepth\u003c\/td\u003e\n\u003ctd\u003e151.3 mm (6.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI520-0540\" target=\"_blank\" rel=\"noopener\"\u003eDual-Channel Universal Process Controller for Industrial Applications - HI520-controller with 5 relays and 4 analog outputs\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871313559921,"sku":"HI520-0540","price":181797.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/520_open_fuse-panel-900x900-e9c0b20e-2680-429b-ac5b-ab5a4217a362_1_3.jpg?v=1792646127"},{"product_id":"iris-visible-spectrophotometer-with-method-identification-via-barcode-reader-hi802","title":"iris® Visible Spectrophotometer with Method Identification via Barcode  Reader - HI802-02","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI802_4-2438x2438-385b52ac-08da-466b-bf6f-87c6c4e9ede2.jpg\" alt=\"Vial barcode reader for HI802\" width=\"594\" height=\"594\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eMethod identification\u003c\/p\u003e\n\u003ch5\u003eVial barcode reader\u003c\/h5\u003e\n\u003cp\u003eAutomatic method identification of barcoded sample vials is an exciting feature of HI802. The HI802 visible spectrophotometer scans an inserted barcoded vial and automatically detects both method type and method range, significantly reducing the risk of errors and aiding measurement procedure.\u003c\/p\u003e\n\u003ch5\u003eVial rotation\u003c\/h5\u003e\n\u003cp\u003eVial rotation during measurement allows for method identification and for a number of absorbance readings. The instrument then converts the readings to concentration units and the result is shown on the LCD display. This rotational averaging of signals during measurement (with the lamp on) ensures improved method accuracy.\nShared single-zero measurement.Use of a single-zero measurement across multiple vial methods where blank correction is done with DI water. This ensures that sample features, rather than instrument changes, are\nreflected in the instrument’s measurements and contributes to ease of use and stable readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI802_8-5168x3448-bfb651bf-1f2a-4c2e-8f9c-f5b939804630-scaled.jpg\" alt=\"iris® Visible Spectrophotometer with Method Identification via Barcode Reader - HI802\" width=\"2560\" height=\"1708\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003ch5\u003eAdvanced split–beam optical system\u003c\/h5\u003e\n\u003cp\u003eIn a spectrophotometer the optical system is the heart of the instrument. Ensuring that the optical system is built with the best design and highest quality materials will guarantee accurate readings and a long life for the meter. When developing this meter our research and development team payed special attention to details and combined many small improvements to a typical spectrophotometer design to create a portable meter with unprecedented performance.\u003c\/p\u003e\n\u003ch5\u003eSpectral range\u003c\/h5\u003e\n\u003cp\u003eThe meter features a spectral range of 340nm to 900nm allowing for a wide selection of analytical methods. The flexibility of this range permits compliance with many methods from regulatory organizations and associations for a variety of applications.\u003c\/p\u003e\n\u003ch5\u003eReplaceable tungsten–halogen lamp\u003c\/h5\u003e\n\u003cp\u003eTo be able to measure in a wide variety of wavelengths a broadband light source is necessary. In the iris® visible spectrophotometer, this is accomplished by a tungsten–halogen lamp. As these lamps do not last indefinitely, it is necessary to change them throughout the life of the meter. The pre–alignment of the lighting fixture guarantees that the bulb is in the same position every time it is changed. This generates peace of mind as there is no need to worry about realigning the light source.\u003c\/p\u003e\n\u003ch5\u003eConcave grating\u003c\/h5\u003e\n\u003cp\u003eThis element of the optical system is what generates the spectrum of light. When the light from the tungsten lamp hits the grating it is met with interference coatings that turn the polychromatic white light into a rainbow. This rainbow contains dispersed light at all wavelengths in the visible spectrum. The rotation of this grating is what allows for a specific wavelength to be selected. This ability is one of the biggest differences between a spectrophotometer and a photometer. The concave grating which accomplishes this is superior to other types of diffraction, such as prisms, as it minimizes stray light generated and has constant bandwidth. It also combines elements of the optical system that would typically be separate, for example if a flat grating was used a concave mirror would need to be added in order to refocus the light. The combination of these two pieces creates greater efficiency and a smaller optical system to yield a more compact portable meter.\u003c\/p\u003e\n\u003ch5\u003eBeam splitter\u003c\/h5\u003e\n\u003cp\u003eThe beam splitter is added to the optical system for use with a reference detector to ensure that the measurement compensates for any drift in the light source. It works by splitting the light emitted by the tungsten lamp into two beams and sending one beam of light to the reference detector that measures intensity. If there are any fluctuations in the light source the meter detects this and compensates through a mathematical calculation. The reference detector also saves battery life and leads to improved speed of the meter as the lamp doesn’t\nhave to warm up prior to use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eiris® Visible Spectrophotometer with Method Identification via Barcode Reader - HI802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength range\u003c\/td\u003e\n\u003ctd\u003e340 to 900 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength resolution\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 3.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric accuracy\u003c\/td\u003e\n\u003ctd\u003e5 mAbs at 0.000 to 0.500 Abs,\n1 % at 0.500 to 3.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement mode\u003c\/td\u003e\n\u003ctd\u003eTransmittance (%), absorbance and concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample cell\u003c\/td\u003e\n\u003ctd\u003e10 mm square, 50 mm rectangular,\n16 mm round, 22 mm round, 13 mm round (vial) with barcode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength selection\u003c\/td\u003e\n\u003ctd\u003eAutomatic, based on the selected method (editable for user\nmethods only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eTungsten halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical system\u003c\/td\u003e\n\u003ctd\u003eSplit beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength calibration\u003c\/td\u003e\n\u003ctd\u003eInternal, automatic at power-on (with visual feedback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.1 % T at 340 nm with NaNO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral bandwidth\u003c\/td\u003e\n\u003ctd\u003e5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of methods\u003c\/td\u003e\n\u003ctd\u003eUp to 150 factory (103 pre-loaded), up to 100 user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData points stored\u003c\/td\u003e\n\u003ctd\u003e9999 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport capability\u003c\/td\u003e\n\u003ctd\u003ecsv file format, pdf file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1x USB A (mass storage host), 1x USB B (mass storage device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e3000 measurements or 8 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e15 Vdc power adapter, 10.8 Vdc Li-ion rechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F), 0 to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e155 x 205 x 322 mm (6.1 x 8.0 x 12.6\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg (6.6 Ibs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI802-01 (115V) and HI802-02 (230V) is supplied with sample cuvette and cap,\u003cbr\u003e\n22 mm (4 pcs.), cuvette adapter (3 pcs.), vial adapter with barcode reading feature ,\u003cbr\u003e\ncloth for wiping cuvettes, scissors, USB cable, 15 VDC power adapter, USB flash drive,\u003cbr\u003e\ninstrument quality certificate, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI802\" target=\"_blank\" rel=\"noopener\"\u003e iris® Visible Spectrophotometer with Method Identification via Barcode Reader - HI802\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871459443057,"sku":"HI802-02","price":430920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI802_Cuvette-22mm-2100x2100-5d91fb98-b9eb-4b18-b2b3-84854b9f7a4e.jpg?v=1792646960"},{"product_id":"hi6553-02-ph-orp-ise-and-ec-tds-and-do-benchtop-meter-starter-kit","title":"HI6553-02 pH\/ORP\/ISE and EC\/TDS and DO Benchtop Meter Starter Kit","description":"\u003cp\u003eHI6553-02 (EU power plug) is supplied with HI6000 housing unit; HI6000-2 pH\/ORP\/ISE hardware module (installed); HI6000-3 EC hardware module (installed); HI6000-4 DO hardware module (installed); HI1131B pH electrode; HI7662-TW temperature probe; HI7631233 EC \u0026amp; resistivity probe; HI7641133 optical DO probe; pH 4.01 buffer solution, 2 sachets; pH 7.01 buffer solution, 2 sachets; pH 10.01 buffer solution, 2 sachets; electrode cleaning solution, 2 sachets; pH \u0026amp; ORP electrode storage solution (25 mL); 3.5M KCl electrolyte solution (30 mL); capillary pipette, 1 piece; 1413 μS\/cm standard solution, 2 sachets; 5000 μS\/cm standard solution, 2 sachets; 12880 μS\/cm standard solution, 2 sachets; Electrode rinse solution, 2 sachets; DO Smart Cap with O-ring, 1 pc. of each; calibration\/storage vessel, 1 piece; Lens cleaning wipe, 1 piece; syringe and sachet with silicone grease, 1 piece of each; electrode holder with base plate, screw, cable holder clip (requires mounting), adapter (attached); 24 VDC power adapter; USB-C to USB-A cable; meter quick reference guide; hardware modules quick reference guides and quality certificates; Smart Cap, probes, and meter quality certificates.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003cthead style=\"color: #292f36;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"font-weight: bold;\"\u003eSpecification Name\u003c\/th\u003e\n\u003cth style=\"font-weight: bold;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI6553-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; - 2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eStandard Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustom Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCustom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOption to select from eight standard buffers and user-defined custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFirst Calibration Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOffset or Point (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eIsopotential Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point offset, ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯5\u003c\/sup\u003e to 300.0 ppt (g\/L or mg\/mL)\n5.0×10\u003csup style=\"font-weight: 500;\"\u003e¯3\u003c\/sup\u003e to 1.0×10\u003csup style=\"font-weight: 500;\"\u003e5\u003c\/sup\u003e ppm (mg\/L or µg\/mL)\n1.0 to 5.0×10\u003csup style=\"font-weight: 500;\"\u003e7\u003c\/sup\u003e ppb (µg\/L)\n1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯7\u003c\/sup\u003e to 10.0 M (mol\/L)\n1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯4\u003c\/sup\u003e to 1.0×10\u003csup style=\"font-weight: 500;\"\u003e4\u003c\/sup\u003e mmol\/L\n1.0×10\u003csup style=\"font-weight: 500;\"\u003e¯6\u003c\/sup\u003e to 60.0 %w\/v\n5.0×10\u003csup style=\"font-weight: 500;\"\u003e¯7\u003c\/sup\u003e to 5.0×10\u003csup style=\"font-weight: 500;\"\u003e7\u003c\/sup\u003e user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAll Standards; Standard Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e7 standard solutions available for each concentration unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Custom Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eISE Custom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Cell Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0500 to 200.0000 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle; Up to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity Calibration Solutions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e84 μS\/cm; 1413 μS\/cm; 5000 μS\/cm; 12880 μS\/cm; 80000 μS\/cm; 111800 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eResistivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 Ω•cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU; 0.01 ppt; 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 point, using 100 % salinity calibration solution (% scale only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eManual\n\u0026gt; 0.00 to 45.00 PSU or ppt\n\u0026gt; 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Range (HI7641133 optical DO probe)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0 % saturation; 0.00 to 90.00 mg\/L (ppm) concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 % saturation; 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eRefer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 100.0 % (8.26 mg\/L) and 0.0 % (0.00 mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Manual (user entered value in % saturation, mg\/L, or ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e450.0 to 850.0 mmHg; 600.0 to 1133.2 mbar; 60.00 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±3 mmHg within ±15 % from calibration point; ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBarometric Pressure Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic (meter-integrated barometer); Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor pH and conductivity: ±0.2 °C; ±0.4 °F; ±0.2 K\nFor DO: Refer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor pH and DO: Automatic; Manual\nFor Conductivity: Linear; Natural; Standard; Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReference Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFor Conductivity: 0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDirect\nDirect\/Autohold\nFor ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction\nFor Conductivity: Direct\/USP\nFor DO Only: OUR, SOUR, BOD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eBasic View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eMeasurement data; Measurement profile (if enabled); Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSimple GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nFor pH: Last calibration date, slope, offset (pH, Rel. mV - ISE only)\nFor Conductivity: Last calibration date and offset\nFor DO: Last calibration date, offset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eFull GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSimple GLP Information; Calibration point details (pH, ISE, conductivity, salinity, and DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eGraph View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic view information; Measurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTable View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eBasic view information; Table with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading Stability Criteria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eReading Sampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Manual; Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Number of Records\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e50,000 maximum per file and stores at least 1,000,000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Automatic Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Sample ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIncremental Mode; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging Export Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e.CSV file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity USB-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e2 ports\nkeyboard and\/or printer input\nUSB Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity USB-C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 port\nPC Connectivity and USB-C Type Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFTP; Web Server (Log transfer and download); Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConnectivity RS232\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration Reminder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDaily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eUsers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240 VAC to 24 VDC 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C \/ 32 to 122 °F \/ 273 to 323 K maximum 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 \")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e8.05 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460852081,"sku":"HI6553-02","price":253874.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6553-White__49705.jpg?v=1792646970"},{"product_id":"ph-orp-ise-conductivity-dissolved-oxygen-kit-hi6553p-02","title":"pH\/ORP\/ISE, Conductivity, Dissolved Oxygen Kit - HI6553P-02","description":"\u003cp\u003eHI6553P-02 (EU power plug) is supplied with HI6000 housing unit; one HI6000-2 pH\/ORP\/ISE hardware module (installed); HI6000-3 EC hardware module (installed); HI6000-4 DO hardware module (installed); HI1131B pH electrode; HI7662-TW temperature probe; HI7631233 EC \u0026amp; resistivity probe; HI764833 polarographic DO probe; pH 4.01 buffer solution, 2 sachets; pH 7.01 buffer solution, 2 sachets; pH 10.01 buffer solution, 2 sachets; electrode cleaning solution, 2 sachets; pH \u0026amp; ORP electrode storage solution (25 mL); 3.5M KCl electrolyte solution (30 mL); DO electrolyte solution (30 mL); capillary pipette, 1 piece; 1413 μS\/cm standard solution, 2 sachets; 5000 μS\/cm standard solution, 2 sachets; 12880 μS\/cm standard solution, 2 sachets; electrode rinse solution, 2 sachets; pH electrode cap; membrane cap and O-ring, 2 pieces; electrode holder with base plate, screw, cable holder clip (requires mounting), adapter (attached); 24 VDC power adapter; USB-C to USB-A cable; meter quick reference guide; hardware modules quick reference guides and quality certificates; probes and meter quality certificates.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable width=\"1229\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSpecification Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eHI6553P-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; – 2.000 to 20.000 Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003epH Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCalibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCalibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eStandard Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eHanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCustom Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCustom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eOption to select from eight standard buffers and user-defined custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eFirst Calibration Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eOffset or Point (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eIsopotential Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSingle point offset, ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1.0×10\u003csup\u003e¯5\u003c\/sup\u003e to 300.0 ppt (g\/L or mg\/mL)\n5.0×10\u003csup\u003e¯3\u003c\/sup\u003e to 1.0×10\u003csup\u003e5\u003c\/sup\u003e ppm (mg\/L or µg\/mL)\n1.0 to 5.0×10\u003csup\u003e7\u003c\/sup\u003e ppb (µg\/L)\n1.0×10\u003csup\u003e¯7\u003c\/sup\u003e to 10.0 M (mol\/L)\n1.0×10\u003csup\u003e¯4\u003c\/sup\u003e to 1.0×10\u003csup\u003e4\u003c\/sup\u003e mmol\/L\n1.0×10\u003csup\u003e¯6\u003c\/sup\u003e to 60.0 %w\/v\n5.0×10\u003csup\u003e¯7\u003c\/sup\u003e to 5.0×10\u003csup\u003e7\u003c\/sup\u003e user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1, 2, 3 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAll Standards; Standard Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e7 standard solutions available for each concentration unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Custom Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Custom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading or ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Cell Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.0500 to 200.0000 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSingle; Up to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Calibration Solutions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e84 μS\/cm; 1413 μS\/cm; 5000 μS\/cm; 12880 μS\/cm; 80000 μS\/cm; 111800 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eResistivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eResistivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eResistivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading or ±1 Ω•cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.01 PSU; 0.01 ppt; 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1 point, using 100 % salinity calibration solution (% scale only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eManual\n\u0026gt; 0.00 to 45.00 PSU or ppt\n\u0026gt; 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Range (\u003cspan style=\"color: #4d4d4d;\"\u003eHI764833 polarographic DO probe)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.0 to 300.0 % saturation; 0.00 to 45.00 mg\/L (ppm) concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 % saturation; 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eRefer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eOne or two points at 100.0 % (8.26 mg\/L) and 0.0 % (0.00 mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Manual (user entered value in % saturation, mg\/L, or ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e450.0 to 850.0 mmHg; 600.0 to 1133.2 mbar; 60.00 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±3 mmHg within ±15 % from calibration point; ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic (meter-integrated barometer); Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e−20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor pH and conductivity: ±0.2 °C; ±0.4 °F; ±0.2 K\nFor DO: Refer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor pH and DO: Automatic; Manual\nFor Conductivity: Linear; Natural; Standard; Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReference Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor Conductivity: 0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReading Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eDirect\nDirect\/Autohold\nFor ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction\nFor Conductivity: Direct\/USP\nFor DO Only: OUR, SOUR, BOD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBasic View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eMeasurement data; Measurement profile (if enabled); Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSimple GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eBasic view information\nFor pH: Last calibration date, slope, offset (pH, Rel. mV – ISE only)\nFor Conductivity: Last calibration date and offset\nFor DO: Last calibration date, offset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eFull GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSimple GLP Information; Calibration point details (pH, ISE, conductivity, salinity, and DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eGraph View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eBasic view information; Measurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTable View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eBasic view information; Table with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReading Stability Criteria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReading Sampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Manual; Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Number of Records\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e50,000 maximum per file and stores at least 1,000,000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Automatic Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Sample ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eIncremental Mode; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Export Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e.CSV file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity USB-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e2 ports\nkeyboard and\/or printer input\nUSB Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity USB-C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1 port\nPC Connectivity and USB-C Type Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFTP; Web Server (Log transfer and download); Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity RS232\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCalibration Reminder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eDaily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eUsers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eDC adapter 100-240 VAC to 24 VDC 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0 to 50 °C \/ 32 to 122 °F \/ 273 to 323 K maximum 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e8.05 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460884849,"sku":"HI6553P-02","price":195264.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6553-White__49705-1.jpg?v=1792646970"},{"product_id":"multiparameter-bluetooth-portable-ph-ec-turbidity-opdo-meter-hi98594","title":"Multiparameter Bluetooth® Portable pH\/EC\/Turbidity\/OPDO® Meter - HI98594","description":"\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003cbr\u003e\nHI98594 can display from 1 to 14 parameters on the high contrast backlit LCD. The pH, EC and\u003cbr\u003e\nDO measurements are automatically compensated for temperature variations. Dissolved\u003cbr\u003e\noxygen concentration measurements are automatically compensated for barometric pressure\u003cbr\u003e\nand salinity.\u003cbr\u003e\n\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003cbr\u003e\nHI98594 can be used to log one data point or continuously log at selected time intervals. All\u003cbr\u003e\nlogs have the option to store data into a named lot and the ability to add remarks. Both help to\u003cbr\u003e\nprovide for meaningful data including notes on local environmental conditions.\u003cbr\u003e\nDual Power Source\u003cbr\u003e\nThe meter operates on a built-in lithium-ion battery. When the rechargeable battery is low\u003cbr\u003e\nthe meter will automatically switch to the 1.5 AA alkaline batteries.\u003cbr\u003e\n\u003cstrong\u003eQuick-Calibration\u003c\/strong\u003e\u003cbr\u003e\nQuick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved\u003cbr\u003e\noxygen. Standard calibration options are available including pH up to three points,\u003cbr\u003e\nconductivity at one point, turbidity with 3 provided standards and dissolved oxygen up to two\u003cbr\u003e\npoints.\u003cbr\u003e\n\u003cstrong\u003eGLP Data\u003c\/strong\u003e\u003cbr\u003e\nCalibration information is captured along with time and date stamp. Information includes\u003cbr\u003e\ncalibration values along with other values that have an impact on the measurement. GLP data\u003cbr\u003e\nis stored with logged data.\u003cbr\u003e\n\u003cstrong\u003eBluetooth® 5.0 Connectivity and Hanna Lab App Compatibility\u003c\/strong\u003e\u003cbr\u003e\nHI98594 offers the ability to connect wirelessly to a smart device running the Hanna Lap App.\u003cbr\u003e\nUsing the app, log lots can be e-mailed or downloaded for review.\u003cbr\u003e\n\u003cstrong\u003eShare\u003c\/strong\u003e\u003cbr\u003e\nLogs can be shared as a .CSV or PDF.\u003cbr\u003e\n\u003cstrong\u003eGLP\u003c\/strong\u003e\u003cbr\u003e\nComprehensive GLP data can be reviewed for all parameters when the logged data is\u003cbr\u003e\ndownloaded to a smart device.\u003cbr\u003e\n\u003cstrong\u003eUnit Selection\u003c\/strong\u003e\u003cbr\u003e\nWhen reviewing data on a smart device there is an option to select the measurement units to\u003cbr\u003e\nbe displayed independently of the meter settings.\u003cbr\u003e\n\u003cstrong\u003eData Graphing\u003c\/strong\u003e\u003cbr\u003e\nFor trend analysis the Hanna Lab App offers the option to graph logged data.\u003cbr\u003e\n\u003cstrong\u003eMulti-function Sensor\u003c\/strong\u003e\u003cbr\u003e\nPre-installed Sensors\u003cbr\u003e\nThe HI7698594 is supplied with pre-installed pH\/ORP, EC\/Turbidity and optical DO sensors\u003cbr\u003e\n\u003cstrong\u003eQuick sensor replacement\u003c\/strong\u003e\u003cbr\u003e\nSensor replacement is quick and easy with field replaceable, screw type connectors and are\u003cbr\u003e\ncolor coded for easy identification. These meters automatically recognize sensors.\u003cbr\u003e\n\u003cstrong\u003eOptical Dissolved Oxygen Smart Caps\u003c\/strong\u003e\u003cbr\u003e\nThe optical dissolved oxygen sensor uses a smart cap that has an RFID tag that stores\u003cbr\u003e\ncalibration coefficients unique to each cap. The RFID keeps track of the age of the cap and\u003cbr\u003e\nalerts the user when it should be replaced.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98594\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMultiparameter Bluetooth® Portable pH\/EC\/Turbidity\/OPDO® Meter - HI98594\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH* \/ ±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH \/ ±1.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Calibration\u003c\/td\u003e\n\u003ctd\u003e•One point using HI9828-20 Quick calibration solution\n•Up to three points using pH 4.01, pH 6.86, pH 7.01, pH\n9.18, pH 10.01 standard buffers and one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0 % saturation\n0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 % saturation\n0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e•±1.5 % of reading from 0.0 to 200.0 % saturation\n•±5 % of reading from 200.0 to 500.0 % saturation\n•±1.5 % of reading from 0.00 to 20.00 mg\/L\n•±5 % of reading from 20.00 to 50.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO calibration\u003c\/td\u003e\n\u003ctd\u003e•One point, quick calibration in water-saturated air\n•One or two points, at 100 % and 0 %\n•One point, using a custom solution (% saturation or mg\/L )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic 450 to 850 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm\n0 to 400 mS\/cm (absolute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e•Manual\n1 μS\/cm\n0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm\n•Automatic\n1 μS\/cm from 0 to 9999 μS\/cm\n0.01 mS\/cm from 10.00 to 99.99 mS\/cm\n0.1 mS\/cm from 100.0 to 400.0 mS\/cm\n•Automatic (mS\/cm)\n0.001 mS\/cm from 0.000 to 9.999 mS\/cm\n0.01 mS\/cm from 10.00 to 99.99 mS\/cm\n0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e•One point using HI9828-20 Quick calibration solution\n•One point using 84 μS\/cm, 1413 μS\/cm, 5.00 mS\/cm,\n12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm standard\nsolutions or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω·cm\n0 to 1000.0 kΩ·cm\n0 to 1.0000 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω·cm\n0.1 kΩ·cm\n0.0001 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range*\u003c\/td\u003e\n\u003ctd\u003e0 to 400000 ppm (mg\/L)\n(the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e•Manual\n1 ppm (mg\/L)\n0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L)\n•Automatic\n1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L)\n0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L)\n0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L)\n•Automatic: ppt (g\/L)\n0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L)\n0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L)\n0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calilbration\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003eOne point, using a custom solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt , σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt , σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Calibration\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 FNU\n100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 FNU from 0.0 to 99.9 FNU\n1 FNU from 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 FNU or ±2 % of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Calibration\/td\u0026gt;\u003c\/td\u003e\n\u003ctd\u003eAutomatic\nUp to three points using 0 FNU, 20 FNU, 200 FNU, and a\ncustom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Range\u003c\/td\u003e\n\u003ctd\u003e450.0 to 850.0 mmHg\n17.72 to 33.46 inHg\n600.0 to 1133.2 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mmHg\n0.01 inHg\n0.1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3.0 mmHg within ±15 °C from calibration temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−5.00 to 50.00 °C\n23.00 to 122.00 °F\n268.15 to 323.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\n0.01 °F\n0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15 °C\n±0.27 °F\n±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Temperature compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Logging memory\u003c\/td\u003e\n\u003ctd\u003e•Interval logging 50000 records\n•Log-on-demand (all parameters) 20000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Logging interval\u003c\/td\u003e\n\u003ctd\u003e1 second to 3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - USB-C (Host) functions\u003c\/td\u003e\n\u003ctd\u003eMass-storage host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - USB-C (Device) functions\u003c\/td\u003e\n\u003ctd\u003eMass-storage device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Protection rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Environment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Battery type\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5 V AA alkaline batteries\n1 x internal, Li-ion rechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Battery life\u003c\/td\u003e\n\u003ctd\u003e≈ 126 hours\n90 hours using alkaline AA batteries\n36 hours using Li-ion battery**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Dimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Weight\u003c\/td\u003e\n\u003ctd\u003e435 g (13.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eAll HI98594 models are supplied with:\u003cbr\u003e\nHI7698594 Multisensor probe\u003cbr\u003e\nHI7698296 Protective probe shield\u003cbr\u003e\nHI76984942 Probe maintenance kit\u003cbr\u003e\nHI7698194-1 pH \/ ORP sensor\u003cbr\u003e\nHI7698594-4 EC \/ Turbidity sensor\u003cbr\u003e\nHI7698594-5 Optical DO sensor\u003cbr\u003e\nHI764113-1 DO Smart Cap with o-ring\u003c\/p\u003e\n\u003cp\u003eHI7698293 Long calibration beaker\u003cbr\u003e\nHI9828-25 Quick calibration standard solution (500 mL)\u003cbr\u003e\nHI7040 Zero oxygen solution set (120 mL)\u003cbr\u003e\nHI9829-16 0 FNU calibration solution (230 mL)\u003cbr\u003e\nHI9829-17 20 FNU calibration solution (230 mL)\u003cbr\u003e\nHI9829-18 200 FNU calibration solution (230 mL)\u003cbr\u003e\nHI710034 Protective rubber boot\u003cbr\u003e\nHI920016 USB cable\u003cbr\u003e\n1.5V AA alkaline batteries (4 pieces)\u003cbr\u003e\nQuality certificates (instrument, probe, DO Smart Cap)\u003cbr\u003e\nQuick reference guide\u003c\/p\u003e\n\u003cp\u003eHI98594 is supplied with multisensor probe with 4m (13.1’) cable\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98309\" target=\"_blank\" rel=\"noopener\"\u003eMultiparameter Bluetooth® Portable pH\/EC\/Turbidity\/OPDO® Meter - HI98594\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461081457,"sku":"HI98594","price":444386.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98594-Front-Boot-4372x4373-576a180c-4bf8-43dd-8d9f-23605bc733c7-1-scaled.jpg?v=1792646974"},{"product_id":"multiparameter-ph-ec-ise-turbidity-do-portable-meter-with-gps-and-autonomously-logging-probe-hi98394","title":"Multiparameter pH\/EC\/ISE\/Turbidity\/DO Portable Meter with GPS and Autonomously Logging Probe - HI98394","description":"\u003cp\u003eHI98394 is a portable logging multiparameter system (meter and autonomously logging probe) that monitors up to 14 different water quality parameters (7 measured and 7 calculated) such as pH, ORP, turbidity, dissolved oxygen, conductivity, chloride, nitrate, ammonium and temperature. Each parameter is fully configurable.\u003cbr\u003eHI98394 has a graphic, backlit display that automatically sizes the digits to fit the screen with on‑screen graphing capability. HI98394 features an internal 12-channel GPS receiver \/ antenna module that guarantees a position accuracy of 10 m (30 ft). GPS information can be transferred to a PC and can be viewed using GPS mapping software. Clicking on visited locations, using a mapping software, displays the measurement information. The GPS coordinates are shown on the LCD together with up to 10 measurement parameters, and are recorded with logged data. A 3-bar antenna indicator, in the bottom right corner of the LCD, indicates GPS signal strength.\u003cbr\u003eThe multisensor probe features an internal temperature sensor and a removable protective shield.\u003cbr\u003eThe probe is compatible with:\u003cbr\u003e• HI7698194-1 sensor for pH and ORP measurements\u003cbr\u003e• HI7609829-10 (ISE ammonium), HI7609829-11 (ISE chloride),\u003cbr\u003eHI7609829-12 (ISE nitrate) can be substituted for pH\/ORP sensors\u003cbr\u003e• HI7698194-2 galvanic DO sensor for dissolved oxygen measurements\u003cbr\u003e• HI7698594-4 sensor for turbidity and conductivity (with associated parameters) measurements\u003cbr\u003eThe HI98394 system is easy to setup and use. The built-in tutorial mode guide users step-by-step through sensor preparation, installation, maintenance, and calibration processes. The meters can log data that can be easily downloaded as a .csv file (or graph) to a type-C, USB flash drive. The HI98394 is designed to withstand harsh environmental conditions and are ideal for field measurements. Each meter comes with a protective\u003cbr\u003erubber boot and meets IP67 standard (30 minutes immersion at 1 meter depth). The multisensor probe is totally sealed against water and dust, and meets IP68 standard (continuous immersion in water).\u003c\/p\u003e\n\u003ch5\u003eMain feature points\u003c\/h5\u003e\n\u003cp\u003e• Monitors up to 14 different water quality parameters\u003cbr\u003e• Rugged, water-resistant meter and waterproof probe\u003cbr\u003e• Autonomously logging probe with weighted cap\u003cbr\u003e• Field-replaceable sensors with auto recognition\u003cbr\u003e• Instantaneous conductivity and turbidity measurements\u003cbr\u003e• Built-in barometer for percent saturation and\u003cbr\u003eDO concentration compensation\u003cbr\u003e• Good Laboratory Practice feature, the last 5\u003cbr\u003ecalibrations are automatically stored\u003cbr\u003e• Graphical display of logged data on backlit LCD screen\u003cbr\u003e• Log-on-demand and automatic logging on meter for all parameters\u003cbr\u003e• Quick calibration feature to provide single point calibration for pH, conductivity, and dissolved oxygen with one solution\u003cbr\u003e• Probe shipped with sensors installed\u003cbr\u003e• Waterproof Quick Connect DIN connection between meter and probe\u003cbr\u003e• USB-C interface for PC communication\u003c\/p\u003e\n\u003ch5\u003eRugged Custom Carrying Case\u003c\/h5\u003e\n\u003cp\u003e• The HI98394 meter, probe*, and all accessories are supplied in a rugged carrying case designed to provide years of use.\u003cbr\u003eThe inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.\u003c\/p\u003e\n\u003ch4\u003eOrdering Info\u003c\/h4\u003e\n\u003cp\u003eHI98394 pH\/ORP, EC\/Turbidity, galvanic DO sensors probe\u003c\/p\u003e\n\u003cp\u003eHI98394\/10 pH\/ORP, EC\/Turbidity, galvanic DO sensors probe\u003c\/p\u003e\n\u003cp\u003eHI98394\/20 pH\/ORP, EC\/Turbidity, galvanic DO sensors probe with 20 m (65.6’) cable\u003c\/p\u003e\n\u003cp\u003eHI98394\/30 pH\/ORP, EC\/Turbidity, galvanic DO sensors probe with 30 m (98.4’) cable\u003c\/p\u003e\n\u003cp\u003eHI98394\/40 pH\/ORP, EC\/Turbidity, galvanic DO sensors probe\u003c\/p\u003e\n\u003cp\u003eHI98394\/50 pH\/ORP, EC\/Turbidity, galvanic DO sensors probe\u003cbr\u003ewith 50 m (164’) cable\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461441905,"sku":"HI98394","price":323190.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98394-Front-Boot_full.jpg?v=1792646979"},{"product_id":"standard-automatic-potentiometric-titrator-hi930","title":"Standard Automatic Potentiometric Titrator-HI930","description":"\u003cstyle\u003e\n  .hanna-product-description {\n    color: #333;\n    line-height: 1.6;\n  }\n\n  .hanna-product-description h2 {\n    font-size: 28px;\n    line-height: 1.3;\n    margin: 40px 0 20px;\n    color: #222;\n  }\n\n  .hanna-subheading {\n    font-size: 21px;\n    line-height: 1.4;\n    font-weight: 600;\n    margin: 25px 0 12px;\n    color: #222;\n  }\n\n  .hanna-product-description p {\n    margin: 0 0 18px;\n  }\n\n  .hanna-product-description ul {\n    margin: 0 0 25px;\n    padding-left: 25px;\n  }\n\n  .hanna-product-description li {\n    margin-bottom: 10px;\n  }\n\n  .hanna-intro {\n    margin-bottom: 35px;\n  }\n\n  .hanna-highlight-box {\n    background: #f5f7f8;\n    border-left: 4px solid #0076a8;\n    padding: 25px;\n    margin: 25px 0;\n  }\n\n  .hanna-feature {\n    margin-bottom: 28px;\n  }\n\n  .hanna-feature .hanna-subheading {\n    margin-bottom: 8px;\n  }\n\n  .hanna-industries {\n    display: grid;\n    grid-template-columns: repeat(4, 1fr);\n    gap: 15px;\n    margin: 25px 0 40px;\n  }\n\n  .hanna-industry {\n    background: #f5f5f5;\n    padding: 18px;\n    text-align: center;\n    font-weight: 600;\n    border-radius: 4px;\n  }\n\n  .hanna-comparison,\n  .hanna-specs,\n  .hanna-manual-auto {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0 40px;\n    font-size: 14px;\n  }\n\n  .hanna-comparison th,\n  .hanna-comparison td,\n  .hanna-specs th,\n  .hanna-specs td,\n  .hanna-manual-auto th,\n  .hanna-manual-auto td {\n    border: 1px solid #ddd;\n    padding: 12px;\n    text-align: left;\n    vertical-align: top;\n  }\n\n  .hanna-comparison th,\n  .hanna-specs th,\n  .hanna-manual-auto th {\n    background: #f2f2f2;\n    font-weight: 700;\n  }\n\n  .hanna-specs th {\n    width: 32%;\n  }\n\n  .hanna-manual-auto th {\n    font-size: 18px;\n  }\n\n  .hanna-included {\n    background: #fafafa;\n    padding: 25px;\n    border: 1px solid #ddd;\n    margin-bottom: 40px;\n  }\n\n  .hanna-note {\n    font-size: 13px;\n    color: #666;\n  }\n\n  @media (max-width: 768px) {\n\n    .hanna-product-description h2 {\n      font-size: 24px;\n    }\n\n    .hanna-subheading {\n      font-size: 19px;\n    }\n\n    .hanna-industries {\n      grid-template-columns: 1fr 1fr;\n    }\n\n    .hanna-comparison,\n    .hanna-specs,\n    .hanna-manual-auto {\n      font-size: 13px;\n    }\n\n    .hanna-comparison th,\n    .hanna-comparison td,\n    .hanna-specs th,\n    .hanna-specs td,\n    .hanna-manual-auto th,\n    .hanna-manual-auto td {\n      padding: 9px;\n    }\n  }\n\n  @media (max-width: 480px) {\n\n    .hanna-industries {\n      grid-template-columns: 1fr;\n    }\n\n    .hanna-comparison,\n    .hanna-specs,\n    .hanna-manual-auto {\n      display: block;\n      overflow-x: auto;\n      white-space: nowrap;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hanna-product-description\"\u003e\n\u003c!-- INDUSTRIES --\u003e\n\u003ch2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Hanna12432-1290x821_da3f1bb4-c57f-446d-b39b-3cc10f56af81.jpg?v=1789966462\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2\u003eWhich industries use Automatic Titrators?\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-industries-1024x1024_c3b58256-1c21-4c8c-b065-18c6ad57915f.jpg?v=1789966494\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-industries\"\u003e\n\u003cdiv class=\"hanna-industry\"\u003eFood\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eBeverage Manufacturing\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eLaboratory\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eEducation and Research\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eIndustrial\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003ePetrochemical\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eMunicipalities\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- SPACE SAVING --\u003e\n\u003ch2\u003eSave Valuable Lab Space\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-stirre_caba5c30-3852-4c2e-a2aa-d5605e1efa0e.png?v=1789966545\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eA Simple Setup for Easy Integration\u003c\/div\u003e\n\u003cp\u003eWe thoughtfully designed this automatic titration system to have a small footprint. The flexible electrode holder and magnetic stirrer are directly built into the top of the titrator unit instead of on the side. This ensures that the titrator requires minimal space in a laboratory setting, helping improve workflow and increase productivity.\u003c\/p\u003e\n\u003c!-- FEATURES --\u003e\n\u003ch2\u003eAuto Titrator Features at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eTough Cycoloy® Body and Chemically Resistant Tubing\u003c\/div\u003e\n\u003cp\u003eDurable, heat-resistant and resistant to staining. The titrator menu buttons are part of the display, making it fully sealed and easy to clean.\u003c\/p\u003e\n\u003cp\u003eAspiration and dispensing tubes are constructed of chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light-sensitive reagents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eA Flexible Electrode Holder with Adjustable Arm\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eUse electrodes with different diameters by simply changing the electrode guide.\u003c\/li\u003e\n\u003cli\u003eCreate the best tube alignment for your titration with a rotating holder. There is no need to move electrodes around.\u003c\/li\u003e\n\u003cli\u003eConveniently modify the height of the electrode holder using the adjustable arm and press-to-release button.\u003c\/li\u003e\n\u003cli\u003ePositions the electrodes in the center of the beaker, allowing for smaller sample sizes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eMagnetic Stirrer\u003c\/div\u003e\n\u003cp\u003eStirring ensures uniform mixing of the titrant and sample, allowing the reaction to reach completion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003e40,000-Step Dosing Pump\u003c\/div\u003e\n\u003cp\u003eCapable of dosing extremely small volumes of titrant so you can achieve a very precise endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eMultiple Titration Types\u003c\/div\u003e\n\u003cp\u003ePaired with the right electrode, this potentiometric titrator can perform a variety of standard titrations, including pH and mV tests with fixed endpoints or single equivalence points.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eDynamic Titrant Dosing\u003c\/div\u003e\n\u003cp\u003eGuarantees timely and accurate results by relating the titrant volume dosed to the mV response from the titration reaction. This allows larger doses at the beginning of a titration and smaller, more precise doses near the titration endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eEquivalence Endpoint Detection\u003c\/div\u003e\n\u003cp\u003eCrucial for applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eSignal Stability Timing\u003c\/div\u003e\n\u003cp\u003eMonitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures dependable measurement values throughout the titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eClip Lock™ Exchangeable Burette System\u003c\/div\u003e\n\u003cp\u003eWith this special feature, it only takes a few seconds to exchange titrants and reagents, helping prevent cross-contamination. An audible clicking sound confirms that the Clip Lock is securely in place.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eGutters and Wells\u003c\/div\u003e\n\u003cp\u003eProvides optimal protection against spills. An external gutter system shields important connections from spills, while interior trays help safeguard internal electronics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eSecurity Options for Users\u003c\/div\u003e\n\u003cp\u003eDetermine appropriate permission settings for each user, administrator, or non-administrator level to prevent unwanted edits or changes to titration method options and results.\u003c\/p\u003e\n\u003cp\u003eAdministrators can also set a PIN code on the titrator unit to protect against unauthorized access.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-designed-for-dynamic-environments-704x1024_7fdbcdb8-b26f-4fc1-8182-3f15678d5180.jpg?v=1789966588\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- PH METER --\u003e\n\u003ch2\u003eGet More Done\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-electrode-holder-head-raised-800-627x1024_93388bc5-722a-4318-9cae-4447ed072337.jpg?v=1789966638\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eDoubles as a Research-Grade pH\/mV Meter\u003c\/div\u003e\n\u003cp\u003eWith our versatile Automatic Titrator, multiple analyses can be performed using one sample. This unit functions not only as a titrator, but also as a pH meter and mV\/ORP meter.\u003c\/p\u003e\n\u003cp\u003eHanna Instruments offers a variety of compatible BNC pH electrodes to choose from, allowing you to select the electrode best suited to your application.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI930-SCREENS-ph-Calibration_08e64a48-2d76-42f2-972d-ef10a6fe055f.jpg?v=1789966620\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c!-- MANUAL VS AUTOMATIC --\u003e\n\u003ch2\u003eWhy Switch from Manual to Automatic Titration?\u003c\/h2\u003e\n\u003ctable class=\"hanna-manual-auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eManual Titration\u003c\/th\u003e\n\u003cth\u003eAutomatic Titration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Interpreting Results By Eye Is Tricky and Can Vary \u003c\/strong\u003e\n\u003cp\u003eIndicator colors used to determine the endpoint are subjective and can look different to each operator.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Monitors and Detects the Exact Endpoint for You \u003c\/strong\u003e\n\u003cp\u003eEliminate the guesswork. Once the titration is complete, a digital result is displayed on the easy-to-read screen.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Inconsistent Results and Room for Error \u003c\/strong\u003e\n\u003cp\u003eSeveral operator shift changes can occur in a laboratory, making it difficult to attain reproducible measurements.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Achieve Repeatable Results at the Push of a Button \u003c\/strong\u003e\n\u003cp\u003eUsers can perform and replicate tests the same way each time with high accuracy.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Inconvenient and Inefficient \u003c\/strong\u003e\n\u003cp\u003eManual titrations are time-consuming and require your full attention. Over-titrating and re-running titrations can occur.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Free Up Your Time and Increase Productivity \u003c\/strong\u003e\n\u003cp\u003eAn Automatic Titrator performs the bulk of the work for you. While a titration is running, you can focus on other tasks.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Record Keeping Is a Hassle \u003c\/strong\u003e\n\u003cp\u003eData is documented by hand in a laboratory notebook or entered digitally. Both approaches can be prone to mistakes.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Gain Complete Data Traceability \u003c\/strong\u003e\n\u003cp\u003eGenerate detailed digital reports. Required data is automatically stored for each application and GLP information is recorded.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Increases Chemical Consumption and Expenses \u003c\/strong\u003e\n\u003cp\u003eA high volume of titrant may be needed to compensate for the inability to deliver small doses.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Reduce Titrant and Sample Usage \u003c\/strong\u003e\n\u003cp\u003eThe system can dose extremely small volumes of titrant into small sample sizes, helping minimize waste.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- TRACEABLE DATA --\u003e\n\u003ch2\u003eStay Compliant with Traceable Data Right at Your Fingertips\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-usb_f26501a1-0790-4cfb-a1c5-2f51839563f8.jpg?v=1789966689\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-subheading\"\u003ePrepare for Audits and Meet Requirements\u003c\/div\u003e\n\u003cp\u003eStore up to 50 titration and pH\/mV customizable analysis reports and simply transfer data via USB.\u003c\/p\u003e\n\u003cp\u003eInformation such as date, time, method settings, results and calibration data are recorded with each sample.\u003c\/p\u003e\n\u003cp\u003eIn addition, a real-time titration curve can be displayed during each titration. This is useful when new methods are tested or when a procedure requires optimization.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screenshot-2026-06-17-141017_3b3f702e-701c-421b-9d63-05993c2d2f54.jpg?v=1789966722\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2\u003eApplications and Standard Methods\u003c\/h2\u003e\n\u003ctable class=\"hanna-comparison\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIndustry\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSample\u003c\/th\u003e\n\u003cth\u003eStandard Methods\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGovernment\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkali, Free \u0026amp; Total\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eMineral Carbonized Concrete\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeverage\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory\u003c\/td\u003e\n\u003ctd\u003eAmine Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D6979\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAmine Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D6979\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- HI930 COMPARISON --\u003e\n\u003ch2\u003eWhich Hanna Instruments Automatic Titrator Is Best for Your Testing Needs?\u003c\/h2\u003e\n\u003cp\u003eThe following comparison provides an overview of the HI930, HI931 and HI932 automatic titrators and their capabilities.\u003c\/p\u003e\n\u003ctable class=\"hanna-comparison\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eHI930\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/957b8414-c6ae-4cf8-ac41-e0fac67228dc_2e86f625-4716-4dcf-b360-f2026c4ef571.jpg?v=1789966761\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eHI931\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/81fc29c3-4b76-4fd7-b0a9-ac24e342b708_a496a8e0-605f-4238-99e4-790b4880f6ab.jpg?v=1789966786\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eHI932\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ad4ea1d0-5f85-4e21-92b6-437ae561de8e_5c9d06f6-b44e-497d-b10c-3a8fbbc51970.jpg?v=1789966810\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Boards\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Capability (max.)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeristaltic Pump Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Electrodes\u003c\/td\u003e\n\u003ctd\u003epH, ORP\u003c\/td\u003e\n\u003ctd\u003epH, ORP, ISE, Photometric\u003c\/td\u003e\n\u003ctd\u003epH, ORP, ISE, Photometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Electrode Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutosampler Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Capability\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Type\u003c\/td\u003e\n\u003ctd\u003eMagnetic\u003c\/td\u003e\n\u003ctd\u003eOverhead Propeller\u003c\/td\u003e\n\u003ctd\u003eOverhead Propeller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Location\u003c\/td\u003e\n\u003ctd\u003eIntegrated, on top\u003c\/td\u003e\n\u003ctd\u003eOn the side\u003c\/td\u003e\n\u003ctd\u003eOn the side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLIMS Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter Connection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eDB-25 Parallel Port\u003c\/td\u003e\n\u003ctd\u003eUSB-A on Network Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalance Connection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyboard Connection\u003c\/td\u003e\n\u003ctd\u003eUSB-A (hot swap)\u003c\/td\u003e\n\u003ctd\u003eUSB-A (hot swap) \/ PS\/2\u003c\/td\u003e\n\u003ctd\u003eUSB-A (hot swap) \/ USB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Software Connection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUSB-B\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum No. of Methods\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum No. of Reports\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"hanna-note\"\u003e* All titrators are compatible with the Silver Billet HI148B.\u003c\/p\u003e\n\u003cp class=\"hanna-note\"\u003e** Adapter required for photometric connection on the HI932 Automatic Titrator.\u003c\/p\u003e\n\u003cp class=\"hanna-note\"\u003e*** With the network box you can transfer to a PC and print directly; network box sold separately.\u003c\/p\u003e\n\u003c!-- WHAT'S INCLUDED --\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cdiv class=\"hanna-included\"\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Automatic Potentiometric Titrator (HI930)\u003c\/li\u003e\n\u003cli\u003ePump assembly\u003c\/li\u003e\n\u003cli\u003eBurette assembly kit including burette with 25 mL syringe, aspiration tube with fitting and protection tube, dispensing tube with dispensing tip, protection tube and tube guide, tube locks, tool for burette cap removal and light spectrum protection\u003c\/li\u003e\n\u003cli\u003ePlastic beaker, 100 mL – 3 pcs.\u003c\/li\u003e\n\u003cli\u003eBeaker support\u003c\/li\u003e\n\u003cli\u003eElectrodes holder and support rod with positioning collar and screw\u003c\/li\u003e\n\u003cli\u003eMagnetic stirrer – 1 pc.\u003c\/li\u003e\n\u003cli\u003eStir bars – 2 pcs.\u003c\/li\u003e\n\u003cli\u003ePump and burette locking screws with plastic head\u003c\/li\u003e\n\u003cli\u003eTemperature sensor – 1 pc.\u003c\/li\u003e\n\u003cli\u003eShorting cap – 1 pc.\u003c\/li\u003e\n\u003cli\u003eO-ring set – 5 × 10.5 mm + 5 × 3 mm\u003c\/li\u003e\n\u003cli\u003ePower adapter – 1 pc.\u003c\/li\u003e\n\u003cli\u003eUSB memory stick – 1 pc.\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate – 1 pc.\u003c\/li\u003e\n\u003cli\u003eInstruction manual – 1 pc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"hanna-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalysis Type\u003c\/th\u003e\n\u003ctd\u003eStandard titration (Standardization, Fixed pH\/mV, Equivalence point pH\/mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEndpoint Mode\u003c\/th\u003e\n\u003ctd\u003eFixed mV\u003cbr\u003eFixed pH\u003cbr\u003emV equivalence point (1st or 2nd derivative)\u003cbr\u003epH equivalence point (1st or 2nd derivative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Size\u003c\/th\u003e\n\u003ctd\u003e5 mL, 10 mL, 25 mL, 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Flow Rate\u003c\/th\u003e\n\u003ctd\u003e0.1\/0.3 mL to 2 × burette volume per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.005 mL (5 mL burette)\u003cbr\u003e±0.010 mL (10 mL burette)\u003cbr\u003e±0.025 mL (25 mL burette)\u003cbr\u003e±0.050 mL (50 mL burette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStirrer Type\u003c\/th\u003e\n\u003ctd\u003eIntegrated magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStirrer Range\u003c\/th\u003e\n\u003ctd\u003e200 to 1400 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStirrer Resolution\u003c\/th\u003e\n\u003ctd\u003e100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Range\u003c\/th\u003e\n\u003ctd\u003e−2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Calibration\u003c\/th\u003e\n\u003ctd\u003eSingle point, offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Range\u003c\/th\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Calibration\u003c\/th\u003e\n\u003ctd\u003eUp to 5 points with standard or custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003ctd\u003e−5.0 to 105 °C\u003cbr\u003e23.0 to 221.0 °F\u003cbr\u003e268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1 °C \/ ±0.2 °F \/ ±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Storage Methods\u003c\/th\u003e\n\u003ctd\u003eUp to 15 titration methods (standard and user-defined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Storage Reports\u003c\/th\u003e\n\u003ctd\u003eUp to 50 titrations and pH\/mV reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections – Measurement\u003c\/th\u003e\n\u003ctd\u003e1 × BNC socket (pH, ORP electrodes)\u003cbr\u003e1 × 4 mm banana socket (reference electrode)\u003cbr\u003e1 × RCA socket (temperature sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections – Peripheral\u003c\/th\u003e\n\u003ctd\u003e1 × USB standard A (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode Holder\u003c\/th\u003e\n\u003ctd\u003e4 × multi-purpose slots (titrant tubes)\u003cbr\u003e4 × 12-mm electrode slots (3 integrated, 1 with included adapter)\u003cbr\u003e1 × temperature sensor slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5.7 in. graphical color display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e100 – 240 VAC, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Draw\u003c\/th\u003e\n\u003ctd\u003e0.5 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure Material\u003c\/th\u003e\n\u003ctd\u003eABS, PC-ABS, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e315 × 205 × 375 mm (12.4 × 8.1 × 14.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 3.6 kg (7.9 lbs.) with burette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Environment\u003c\/th\u003e\n\u003ctd\u003e10 to 40 °C (50 to 104 °F), up to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Environment\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C (−4 to 158 °F), up to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- FINAL --\u003e\n\u003cdiv class=\"hanna-highlight-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eStandard Automatic Potentiometric Titrator – HI930\u003c\/div\u003e\n\u003cp\u003eThe HI930 provides a compact and versatile solution for laboratories requiring accurate, repeatable and traceable automatic titration. With precise dosing, multiple titration modes, integrated stirring, pH\/mV measurement and digital data storage, it is designed to simplify routine laboratory analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003csection class=\"banner--product-resources\" style=\"color: #000000;\"\u003e\n\u003cdiv class=\"custom-fields\"\u003e\n\u003cdiv class=\"flex-center\"\u003e\n\u003cdiv class=\"resources-container\"\u003e\n\u003cdiv class=\"tabs-content\" style=\"color: inherit;\"\u003e\n\u003cdiv id=\"specifications-accordion\" class=\"tabs-panel is-active\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"grid-container\"\u003e\n\u003cdiv class=\"table-specs\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eAnalysis Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard titration (Standardization, Fixed pH\/mV, Equivalence point pH\/mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eEndpoint Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed mV Fixed pH mV equivalence point (1st or 2nd derivative) pH equivalence point (1st or 2nd derivative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mL, 10 mL, 25 mL, 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.3 mL to 2 × burette volume per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.005 mL (5 mL burette) ±0.010 mL (10 mL burette) ±0.025 mL (25 mL burette) ±0.050 mL (50 mL burette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStirrer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStirrer Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 to 1400 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStirrer Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point, offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 points with standard or custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−5.0 to 105 °C 23.0 to 221.0 °F 268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C \/ ±0.2 °F \/ ±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eData Storage Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 15 titration methods (standard and user-defined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eData Storage Reports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 50 titrations and pH\/mV reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eConnections Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × BNC socket (pH, ORP electrodes) 1 × 4 mm banana socket (reference electrode) 1 × RCA socket (temperature sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eConnections Peripheral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × USB standard A (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eElectrode Holder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 × multi-purpose slots (titrant tubes) 4 × 12-mm electrode slots (3 integrated, 1 with included adapter) 1 × temperature sensor slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.7 in. graphical color display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 – 240 VAC, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS, PC-ABS, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eKeypad\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 x 205 x 375 mm (12.4 x 8.1 x 14.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 3.6 kg (7.9 lbs.) with burette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 40 °C (50 to 104 °F), up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStorage Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20 to 70 °C (−4 to 158 °F), up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv style=\"color: #000000;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"color: #000000;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"tabs-contents\" style=\"color: #000000;\"\u003e\n\u003cdiv id=\"tab-related\" class=\"tab-content has-jsContent is-active\" role=\"tabpanel\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/pages.hannainst.com\/hubfs\/product-manuals\/MAN930_01_26.pdf?__hstc=4846506.88f998383056e7a1dc413c6f6ed9074c.1781604137253.1781604137253.1781681130757.2\u0026amp;__hssc=4846506.1.1781681130757\u0026amp;__hsfp=ee46b245bab50259c1a5d23673c0a667\"\u003eStandard Automatic Potentiometric Titrator Manual (HI930)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461769585,"sku":"HI930","price":706978.13,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI930-Automatic-Potentiometric-Titrator_Right-Facing-2026__99768.jpg?v=1792646984"}],"url":"https:\/\/hannainst.in\/collections\/new-launch.oembed","provider":"hanna","version":"1.0","type":"link"}