{"title":"Alkalinity","description":"","products":[{"product_id":"stainless-steel-cover-magnetic-mini-stirrer-hi200m","title":"Stainless Steel Cover Magnetic Mini-Stirrer - HI200M-2","description":"\u003cp\u003eIdeally,  when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing and the sample to be homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI200M mini-magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI200M magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI200M stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab,  a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI200M magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With \u003cstrong\u003eSpeedsafe™\u003c\/strong\u003e,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI200M is equipped with a replaceable fuse. The circuitry of the HI200M is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI200M-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Stainless Steel Cover Magnetic Mini-Stirrer - HI200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 120 x 120 x 45 mm (4.8 x 4.8 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 710 g (1.6 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI200M magnetic mini-stirrer is supplied with micro stir bar (1) and instructions\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI200M-1\"\u003eStainless Steel Cover Magnetic Mini-Stirrer - HI200M\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235047793,"sku":"HI200M-2","price":9610.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi200m-front.jpg?v=1792645911"},{"product_id":"magnetic-stir-bars-10-hi731319","title":"Magnetic Stir Bars (10) - HI731319","description":"\u003cp\u003eThe HI731319 set of 10 magnetic stir bars made for a variety of applications. Used in a laboratory setting,  a magnetic stirrer together with magnetic stir bars continually stir buffers and\/or samples to keep them homogeneous. By keeping samples uniform during measurement and titration,  erroneous results are eliminated by preventing any temperature gradients or inadequate mixing when chemicals are added to a sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Magnetic Stir Bars (10) - HI731319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 25 mm x 7 mm \/ 1” x 0.3”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eQuantity: 10\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731319\"\u003eMagnetic Stir Bars (10) - HI731319\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235277169,"sku":"HI731319","price":8250.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731319.jpg?v=1792645914"},{"product_id":"mini-titrator-for-measuring-titratable-alkalinity-in-water-and-wastewater-hi84531","title":"Mini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eAlkalinity is the ability of water to neutralize acids. Total titratable alkalinity is a measure of primarily three types of alkalinities present in a water sample: hydroxides, carbonates, and bicarbonates. Alkalinity in water can be the result of contributions from common chemicals including carbonates, bicarbonates, hydroxides, phosphates, borate and organic acid salts.\u003c\/p\u003e\n\u003cp\u003eThe alkalinity of a water sample indicates its ability to resist pH change. The amount of alkalinity in water is mostly due to the bicarbonate\/carbonate present. A low alkalinity level indicates that the water is susceptible to pH changes, while a high alkalinity level indicates that the water will be able to resist pH changes. Alkalinity can also be used to determine the corrosive capacity of water and can provide an estimation of water hardness.\u003c\/p\u003e\n\u003ch5\u003eDouble Junction pH Electrode\u003c\/h5\u003e\n\u003cp\u003eThe HI84531 is supplied with the HI1131B refillable, double junction, combination pH electrode. By design, the HI1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for direct measurements or acid base titrations in the water industry.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84531 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 600 rpm, regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Help.jpg\" alt=\"titrator screenshot\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Interface\u003c\/strong\u003eThe HI84531 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-Titration-Results.jpg\" alt=\"Titrate LR \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84531-TitrationCurve_400x201_1.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGraphic Mode \u003c\/strong\u003e This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Log.jpg\" alt=\"mini titrator acidity logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eLog-on-Demand\u003c\/strong\u003eThe HI84531 allows for data logging of up to 400 samples: 200 titration results and 200 pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-pH-Electrode-Condition.jpg\" alt=\"mini titrator pH mv meter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003e In addition to being an automatic titrator, the HI84531 also can be used as a pH\/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-CALCheck.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003eAccuracy is always ensured with Hanna's unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty\/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84531 is used as a pH meter, but also an accurate titration since the endpoint of a titratable alkalinity titration is determined by a set pH value.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI84531-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone, two or three-point calibration; four available buffers (4.01, 7.01, 8.30, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003eacid-base titration (strong alkalinity\/total alkalinity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eendpoint titration: 8.30 pH (phenolphthalein) \/ 4.50 pH (bromcresol green-methyl red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 30.0 to 400.0 mg\/L; 0.6 to 8.0 meq\/L\nHigh Range: 300 to 4000 mg\/L; 6.0 to 80.0 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.1 mg\/L (ppm); 0.1 meq\/L; High Range: 1 mg\/L (ppm); 0.1 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±1 mg\/L or 3% of reading, whichever is greater\nHigh Range: ±10 mg\/L or 3% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003eLow Range: 50 mL; High Range: 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eHI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer at 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84531 is supplied with HI1131B pH electrode, HI7662-M temperature probe, HI84531-50 low range titrant (120 mL), HI84531-51 high range titrant (120 mL), HI84531-55 calibration standard (230 mL), 100 mL beakers (2), dosing pump valve, 5 mL syringe, 2000 µL automatic pipette with two plastic tips, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, power adapter, instruction manual and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI84531-01\" target=\"_blank\" rel=\"noopener\"\u003eMini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871244550513,"sku":"HI84531-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84531_1.jpg?v=1792645926"},{"product_id":"heavy-duty-stainless-steel-cover-mini-stirrer-2-5l-hi300n-1","title":"Heavy-Duty Stainless Steel Cover Mini-Stirrer (2.5L) - HI300N-1 - HI300N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing,  ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI300N magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI300N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI300N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI300N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI300N is equipped with a replaceable fuse. The circuitry of the HI300N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI300N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Heavy-Duty Stainless Steel Cover Mini-Stirrer (2.5L) - HI300N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI300N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI300N-1\"\u003eHeavy-Duty Stainless Steel Cover Mini-Stirrer (2.5L) - HI300N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248646513,"sku":"HI300N-2","price":16640.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi300n_v2_1.jpg?v=1792645932"},{"product_id":"auto-reverse-stainless-steel-cover-mini-stirrer-2-5l-hi302n-1","title":"Auto-Reverse Stainless Steel Cover Mini-Stirrer (2.5L) - HI302N-1 - HI302N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements, the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing, ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI302N magnetic stirrer is compact and lightweight, allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable, space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI302N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eAdjustable Auto Reverse\u003c\/h5\u003e\n\u003cp\u003eHI302N stirrer has an adjustable auto-reverse setting. A reverse period knob allows the user to adjust the reverse interval from 30 seconds to 3 minutes. Once the interval time is set, the fluid will rotate in one direction for that amount of time and then reverse its rotation for that same amount of time, all at the desired speed in a repeated cycle until the stirrer is switched off.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI302N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI302N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe, a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level, the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load of glory is suddenly removed from the stirrer, the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety, in the event of a short circuit, the HI302N is equipped with a replaceable fuse. The circuitry of the HI302N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI302N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAuto-Reverse Stainless Steel Cover Mini-Stirrer (2.5L) - HI302N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI302N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI302N-1\" target=\"_blank\" rel=\"noopener\"\u003eAuto-Reverse Stainless Steel Cover Mini-Stirrer (2.5L) - HI302N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248712049,"sku":"HI302N-2","price":17731.0,"currency_code":"INR","in_stock":true}]},{"product_id":"auto-reverse-stainless-steel-cover-mini-stirrer-with-tachometer-2-5l-hi304n-1","title":"Auto-Reverse Stainless Steel Cover Mini-Stirrer with Tachometer (2.5L) - HI304N-1 - HI304N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing,  ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI304N magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI304N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eAdjustable Auto Reverse\u003c\/h5\u003e\n\u003cp\u003eHI304N stirrer has an adjustable auto-reverse setting. A reverse period knob allows the user to adjust the reverse interval from 30 seconds to 3 minutes. Once the interval time is set,  the fluid will rotate in one direction for that amount of time and then reverse its rotation for that same amount of time,  all at the desired speed in a repeated cycle until the stirrer is switched off.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Tachometer\u003c\/h5\u003e\n\u003cp\u003eHI304N stirrer has a built-in 4-digit LCD tachometer that shows the stirring speed in RPM for ultimate accuracy.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI304N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI304N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI304N is equipped with a replaceable fuse. The circuitry of the HI304N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI304N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Auto-Reverse Stainless Steel Cover Mini-Stirrer with Tachometer (2.5L) - HI304N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI304N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI304N-1\"\u003eAuto-Reverse Stainless Steel Cover Mini-Stirrer with Tachometer (2.5L) - HI304N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248744817,"sku":"HI304N-2","price":18844.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi304_v2.jpg?v=1792645933"},{"product_id":"heavy-duty-stainless-steel-cover-mini-stirrer-with-autospeed-5-l-hi310n-1","title":"Heavy-Duty Stainless Steel Cover Mini-Stirrer with Autospeed (5 L) - HI310N-1 - HI310N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing,  ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI310N magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI310N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI310N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI310N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI310N is equipped with a replaceable fuse. The circuitry of the HI310N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch5\u003eAutospeed\u003c\/h5\u003e\n\u003cp\u003eFor Non-newtonian fluids like oil and clay,  the viscosity changes during the stirring process,  making it necessary to adjust the power to maintain a constant speed during the stirring. Hanna Auto-Speed stirrers are designed with automatic feedback control to maintain constant speed when the torque load changes and are therefore ideal for stirring non-Newtonian fluids where the viscosity changes during stirring. They are also ideal for mixing applications where one solution is added to another which changes the capacity and thereby the torque load on the stirrer. The Auto-Speed stirrers maintain a constant stirring speed during the mixing up to the full capacity of 5 liters. They can also be used with Newtonian fluids up to a capacity of 5 liters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI310N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Heavy-Duty Stainless Steel Cover Mini-Stirrer with Autospeed (5 L) - HI310N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI310N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI310N-1\"\u003eHeavy-Duty Stainless Steel Cover Mini-Stirrer with Autospeed (5 L) - HI310N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248810353,"sku":"HI310N-2","price":18844.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi310_v2.jpg?v=1792645934"},{"product_id":"alkalinity-chemical-test-kit-hi3811","title":"Alkalinity Chemical Test Kit - HI3811","description":"\u003cp\u003eThe HI3811 is a titration-based chemical test kit that determines the alkalinity concentration in samples within a 0 to 100 mg\/L (ppm) CaCO\u003csub\u003e3\u003c\/sub\u003e or 0 to 300 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e range. The HI3811 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 110 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the sample beakers,  plastic syringe,  phenolphthalein indicator,  and bromophenol blue indicator.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution \u003c\/strong\u003e\u003cul\u003e\n\u003cli\u003eReadings from 0 to 100 mg\/L are determined to 1 mg\/L resolution\u003c\/li\u003e\n\u003cli\u003eReadings from 0 to 300 mg\/L are determined to 3 mg\/L resolution\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3811-100+I472 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 1 (10mL) dropper bottle of phenolphthalein indicator,  1 (10mL) dropper bottle of bromophenol blue indicator,  and 1 (120mL) bottle of HI3811-0 reagent.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eAlkalinity is the quantitative capacity of a water sample to neutralize an acid to a set pH. This measurement is very important in determining the corrosive characteristics of water due primarily to hydroxide,  carbonate,  and bicarbonate ions. Other sources of alkalinity can be from anions that can be hydrolyzed such as phosphates,  silicates,  borates,  fluoride,  and salts of some organic acids. Alkalinity is critical in the treatments of drinking water,  wastewater,  boiler and cooling systems,  and soils.\u003c\/p\u003e\n\u003cp\u003eAlkalinity can be measured as Phenolphthalein Alkalinity and Total Alkalinity. The Phenolphthalein Alkalinity is determined by neutralizing the sample to a pH of 8.3 using a dilute hydrochloric acid solution and a phenolphthalein indicator. This process converts hydroxide ions to water,  and carbonate ions to bicarbonate ions:\u003c\/p\u003e\n\u003cp\u003eOH\u003csup\u003e-\u003c\/sup\u003e + HCl → H\u003csub\u003e2\u003c\/sub\u003eO + Cl\u003csup\u003e-\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e + HCl → HCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e + Cl\u003csup\u003e-\u003c\/sup\u003e\u003c\/p\u003e\n\u003cp\u003eSince bicarbonate ions can be converted to carbonic acid with additional hydrochloric acid,  the Phenolphthalein Alkalinity measures total hydroxide ions,  but only half of the bicarbonate contribution. To completely convert the carbonate ions,  hydrochloric acid is added until the sample pH is 4.5,  which is known as Total Alkalinity:\u003c\/p\u003e\n\u003cp\u003eHCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e + HCl → H\u003csub\u003e2\u003c\/sub\u003eCO\u003csub\u003e3\u003c\/sub\u003e + Cl\u003csup\u003e-\u003c\/sup\u003e\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3811\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Alkalinity Chemical Test Kit - HI3811\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range) 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003e acid titration using phenolphthalein and bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 460 g (17.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 200x120x60 mm (7.9x4.7x2.4 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3811 test kit comes with 10 mL phenolphthalein indicator, 10 mL bromophenol blue indicator, 120 mL alkalinity titrant, 10 mL calibrated vessel, 50 mL calibrated vessel, and calibrated syringe with tip.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3811\"\u003eAlkalinity Chemical Test Kit - HI3811\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871256707441,"sku":"HI3811","price":5835.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3811.jpg?v=1792645974"},{"product_id":"alkalinity-test-kit-replacement-reagents-110-tests-hi3811-100","title":"Alkalinity Test Kit Replacement Reagents (110 tests) - HI3811-100","description":"\u003cp\u003eThe HI3811-100 are high-quality reagents that are pre-measured,  allowing  users to achieve fast and accurate alkalinity measurements with the chemical test kit. These reagents follow the phenolphthalein\/bromophenol blue method to determine phenolphthalein alkalinity\/total alkalinity concentration.\u003c\/p\u003e\n\u003cp\u003eFor determination of phenolphthalein alkalinity,  the dilute hydrochloric acid titrant neutralizes the sample to the pH endpoint near pH 8.3. With addition of phenolphthalein indicator,  the solution turns pink to visually indicate it is near the pH endpoint. For total alkalinity determination,  dilute hydrochloric acid is also used as the titrant. With addition of bromophenol blue indicator,  the solution turns yellow to blue\/green as it reaches the pH endpoint near pH 4.5. The number of milliliters of titrant used to reach the appropriate endpoint will determine the alkalinity as mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e. These reagents are designed to be used with samples that have an expected alkalinity range of 0 to 100 mg\/L and 0 to 300 mg\/L CaCO\u003csub\u003e3\u003c\/sub\u003e.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3811-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Alkalinity Test Kit Replacement Reagents (110 tests) - HI3811-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 110 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e phenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3811-100\"\u003eAlkalinity Test Kit Replacement Reagents (110 tests) - HI3811-100\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871256904049,"sku":"HI3811-100","price":5129.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3811-100.jpg?v=1792645975"},{"product_id":"water-quality-test-kit-hi3817","title":"Water Quality Test Kit - HI3817","description":"\u003cp\u003eThe HI3817 is a chemical test kit that determines that uses titration,  colorimetry,  and direct measurement to measure six parameters common to water quality testing: alkalinity,  chloride,  hardness,  iron,  pH,  and sulfite. The HI3817 is supplied with all of the necessary reagents and equipment to perform each analysis,  and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the pH tester,  sample beaker,  indicator and reagent bottles and packets,  and color comparison cube.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eSix of the most common parameters in water quality can be monitored with this combination chemical test kit. They include: alkalinity,  chloride,  hardness,  iron,  pH,  and sulfite. These parameters are important in determining the corrosive characteristics of water due to carbonates and chloride. Sulfite is also critical to prevent pitting and oxidation of metal components. A high level of sulfite results in a lowered pH,  which can also promote corrosion in drinking water infrastructure. This kit is ideal not only for professionals,  but also for students studying environmental science,  as it offers great performance and ease of use. HI3817 is equipped with all the accessories and reagents to perform multiple tests for each parameter. The pHep®,  our popular pH electronic tester,  is included for your convenience. This small and easy to use pH meter will provide more accurate and reliable pH readings than conventional litmus paper. The pHep® also has the added benefit of introducing students to the use of a pH meter.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3817\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI3817 Water Quality Test Kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003e electronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003e life of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003e phenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L Cl⁻; 0 to 1000 mg\/L Cl⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 10 mg\/L (0 to 1000 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003e mercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003e EDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Measurement Type\u003c\/td\u003e\n\u003ctd\u003e colorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003e phenanthroline\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 20.0 mg\/L Na₂SO₃; 0 to 200 mg\/L Na₂SO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.2 mg\/L (0.0 to 20.0 mg\/L range); 2 mg\/L (0 to 200 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Method\u003c\/td\u003e\n\u003ctd\u003e iodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3817 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of iron, which include reagents for 50 tests, electronic pH tester, hard carrying case and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3817\"\u003eHI3817 Water Quality Test Kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871257231729,"sku":"HI3817","price":35690.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3817_2.jpg?v=1792645979"},{"product_id":"backpack-lab-water-quality-educational-test-kit-hi3817bp","title":"Backpack Lab Water Quality Educational Test Kit - HI3817BP","description":"\u003cp\u003eThe HI3817BP is a classroom in a backpack! The Backpack Lab Water Quality Educational Test Kit contains lessons, activities, and test kits to help students understand the importance of common water quality parameters. Using titration, colorimetry, and direct measurement, educators and students can easily measure parameters such as acidity, alkalinity, carbon dioxide, dissolved oxygen, hardness, pH, EC, TDS, and turbidity. The HI3817BP is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents and buffers are individually available as they run out. Hanna chemical test kits and pocket testers included in this Backpack Lab provide teachers with a valuable tool in helping students assess the water quality of streams, rivers, and lakes.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTests for ten important water quality parameters\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eClassrooms can gain an extensive understanding of water quality through measurement of these ten parameters:\nAcidity, alkalinity, carbon dioxide, dissolved oxygen, hardness, nitrate, phosphate, pH, EC, and TDS.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete testing setup\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the pH tester, sample beaker, indicator and reagent bottles and packets, and glass bottle for dissolved oxygen.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents and buffers for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive educational material\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThe lesson plan and components are tied together by a comprehensive teacher's manual that includes information about each parameter, classroom activities designed to introduce students to each parameter, and detailed field-testing procedures.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3817BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eBackpack Lab Water Quality Educational Test Kit - HI3817BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at 1382 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003emodified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 500 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 5 mg\/L (0 to 500 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Method\u003c\/td\u003e\n\u003ctd\u003emethyl orange \/ phenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L CO₂; 0.0 to 50.0 mg\/L CO₂; 0 to 100 mg\/L CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (0.0 to 10.0 mg\/L range); 0.5 mg\/L (0.0 to 50.0 mg\/L range); 1 mg\/L (0 to 100 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 50 mg\/L NO₃⁻-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003ecadmium reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mg\/L PO₄³⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Number of Test\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3817BP Backpack Lab includes HI98129 Combo pH\/EC\/TDS\/temperature tester, acidity test kit, alkalinity test kit, carbon dioxide test kit, dissolved oxygen test kit, hardness test kit, nitrate test kit, phosphate test kit, set of 10 field test procedures, teacher's resource CD, teacher's guide and backpack.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3817BP\" target=\"_blank\" rel=\"noopener\"\u003eBackpack Lab Water Quality Educational Test Kit - HI3817BP\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871261720945,"sku":"HI3817BP","price":55321.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3817bp-water-backpack-lab_1200x1200_300_rgb.jpg?v=1792645980"},{"product_id":"cooling-and-boiler-chemical-test-kit-hi3821","title":"Cooling and Boiler Chemical Test Kit - HI3821","description":"\u003cp\u003eThe HI3821 is a chemical test kit that determines that uses titration and colorimetry to measure six parameters common to cooling and boiler systems: alkalinity, chloride, hardness, dissolved oxygen, phosphate, and sulfite. The HI3821 is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the dissolved oxygen glass bottle,  sample beaker,  indicator and reagent bottles and packets,  and color comparison cube.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eCorrosion can occur in many key areas of a boiler. It can shorten the life of a boiler,  or at the very least,  increase the costs associated with maintaining a boiler. Corrosion can form in water heaters,  deaerators,  superheater tubes,  and economizers,  among other places. Monitoring the alkalinity,  chloride,  hardness,  dissolved oxygen,  phosphate,  and sulfite concentrations in cooling and boiler systems is essential in preventing hazardous or costly situations.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Cooling and Boiler Chemical Test Kit - HI3821\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003e modified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003e phenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100 mg\/L Cl⁻; 0 to 1000 mg\/L Cl⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L (0 to 100 mg\/L range); 10 mg\/L (0 to 1000 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003e mercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003e EDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Measurement Type\u003c\/td\u003e\n\u003ctd\u003e colorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 5 mg\/L PO₄³⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003e ascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Number of Test\u003c\/td\u003e\n\u003ctd\u003e 50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 20.0 mg\/L Na₂SO₃; 0 to 200 mg\/L Na₂SO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.2 mg\/L (0.0 to 20.0 mg\/L range); 2 mg\/L (0 to 200 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Method\u003c\/td\u003e\n\u003ctd\u003e iodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 2.5 kg (5.5 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3821 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of phosphate, which includes reagents for 50 tests, hard carrying case, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3821\"\u003eCooling and Boiler Chemical Test Kit - HI3821\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871261917553,"sku":"HI3821","price":48183.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3821_1.jpg?v=1792645983"},{"product_id":"boiler-and-feedwater-chemical-test-kit-hi3827","title":"Boiler and Feedwater Chemical Test Kit - HI3827","description":"\u003cp\u003eThe HI3827 is a chemical test kit that determines that uses titration, colorimetry, and direct measurement to measure six parameters common to boilers and feedwater testing: alkalinity, chloride, hardness, phosphate, pH, and sulfite. The HI3827 is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the pH tester, sample beaker, indicator and reagent bottles and packets, and color comparison cube.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eMonitoring the alkalinity, chloride, hardness, phosphate, pH, and sulfite concentrations in boiler and feedwater is essential in preventing hazardous or costly situations. These parameters are important in determining the corrosive characteristics of water due to carbonates and chloride. Sulfite is also critical to prevent pitting and oxidation of metal components. A high level of sulfite results in a lowered pH, which can also promote corrosion.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3827\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eBoiler and Feedwater Chemical Test Kit - HI3827\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003eelectronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003elife of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L Cl⁻; 0 to 1000 mg\/L Cl⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 10 mg\/L (0 to 1000 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Method\u003c\/td\u003e\n\u003ctd\u003emercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mg\/L PO₄³⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Number of Test\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L Na₂SO₃; 0 to 200 mg\/L Na₂SO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Resolution\u003c\/td\u003e\n\u003ctd\u003e0.2 mg\/L (0.0 to 20.0 mg\/L range); 2 mg\/L (0 to 200 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Method\u003c\/td\u003e\n\u003ctd\u003eiodometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.2 kg (4.8 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3827 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, with the exception of phosphate, which includes reagents for 50 tests, hard carrying case, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3827\" target=\"_blank\" rel=\"noopener\"\u003eBoiler and Feedwater Chemical Test Kit - HI3827\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871267357041,"sku":"HI3827","price":36287.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3827_2.jpg?v=1792645992"},{"product_id":"tube-set-and-valve-for-mini-titrators-hi70500","title":"Tube Set and Valve for Mini Titrators - HI70500","description":"\u003cp\u003eThe HI70500 tube set includes tubing,  filter,  titrant cap,  valve,  valve fittings,  and dosing tip. The tube set allows for the connection between titrant bottle,  syringe,  and sample beaker. The tubing set  is easily replaced and can be connected in a matter of minutes.\u003c\/p\u003e\n\u003cp\u003eThe HI70500 is used with the HI845XX series of mini titrators,  including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84500\u003c\/strong\u003e Sulfur Dioxide Mini Titrator for Wine Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84502\u003c\/strong\u003e Total Acidity Mini Titrator for Wine Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84529\u003c\/strong\u003e Titratable Acidity Mini Titrator for the Dairy Industry\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84530\u003c\/strong\u003e Titratable Acidity Mini Titrator for Water Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84531\u003c\/strong\u003e Titratable Alkalinity Mini Titrator for Water Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84532\u003c\/strong\u003e Titratable Acidity Mini Titrator for Fruit Juices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84533\u003c\/strong\u003e Formol Number Mini Titrator for Wines and Fruit Juices\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Tube Set and Valve for Mini Titrators - HI70500\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70500\"\u003eTube Set and Valve for Mini Titrators - HI70500\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871367233905,"sku":"HI70500","price":12597.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70500.jpg?v=1792646269"},{"product_id":"magnetic-stir-bars-10-medium-sized-hi731320","title":"Magnetic Stir Bars (10) Medium Sized - HI731320","description":"\u003cp\u003eThe HI731320 set of 10 magnetic stir bars made for a variety of applications. Used in a laboratory setting,  a magnetic stirrer together with magnetic stir bars continually stir buffers and\/or samples to keep them homogeneous. By keeping samples uniform during measurement and titration,  erroneous results are eliminated by preventing any temperature gradients or inadequate mixing when chemicals are added to a sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Magnetic Stir Bars (10) Medium Sized - HI731320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e L 50 mm x dia 7 mm\/ 2 in. x 0.3 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eQuantity: 10\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731320\"\u003eMagnetic Stir Bars (10) Medium Sized - HI731320\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871393415537,"sku":"HI731320","price":10619.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731319_3.jpg?v=1792646363"},{"product_id":"iris-visible-spectrophotometer-hi801","title":"iris Visible Spectrophotometer - HI801-02","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/iris-rainbow.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSuperior design for superior results.\u003c\/h4\u003e\n\u003cp\u003eiris can test a wide variety of analytical measurements and is capable of measuring in a spectral range of 340 nm to 900 nm.\u003c\/p\u003e\n\u003cp\u003eWith the compact design of its advanced optical system, iris can be used in almost any sized space while providing accurate and consistent results. The split beam optical system allows iris to automatically compensate for any drift in light source, resulting in superior accuracy.\u003c\/p\u003e\n\u003ch4\u003eNo need for measurement conversions.\u003c\/h4\u003e\n\u003cp\u003eWhether you are testing for chlorine or running enzymatic assays, our spectrophotometer will conveniently display results in the units that matter most to you. iris can measure in transmittance, absorbance, and concentration based on your need.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801-Hand.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eThe convenience of pre-programmed methods with the option to expand.\u003c\/h4\u003e\n\u003cp\u003eiris comes pre-programmed with more than 80 commonly used chemical analysis methods to help you get started. Simply update these methods by connecting to a computer or flash drive.\u003c\/p\u003e\n\u003cp\u003eCustomize your iris with up to 100 personal methods. iris will guide you through the method creation process step-by-step. For added versatility, each method can include up to 10 calibration points, five different wavelengths, and up to five reaction timers.\u003c\/p\u003e\n\u003cp\u003eEasily access your favorite methods directly from the home screen to save time.\u003c\/p\u003e\n\u003cp\u003eBuilt in timers make make measuring seamless. The countdown timer displays the time remaining until a measurement will be taken, ensuring consistent results between measurements and users. If you get stuck, the tutorial mode will walk you through the steps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/IRIS-with-light.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eChange sample size easily.\u003c\/h4\u003e\n\u003cp\u003eWith our universal cuvette holder and auto-recognition feature, cuvette sizes can be changed when needed. The programmed cuvette size will be displayed on the screen every time you test to ensure that the proper path length is being used by the meter when calculating measurements for correct results.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Cuvette-Insert-Round.jpg\" alt=\"sides\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eRound\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Cuvette-Insert-Vial.jpg\" alt=\"data logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eVial\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Cuvetter-Insert-Square.jpg\" alt=\"basic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eSquare\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Lamp-removal.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eWorry free replacements.\u003c\/h4\u003e\n\u003cp\u003eiris uses a tungsten-halogen lamp for greater energy efficiency, longer service life, and improved light quality for a wide variety of wavelengths. Replacement lamps are shipped pre-aligned and ready for installation so that you can get back to testing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Battery.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eDesigned for dynamic environments.\u003c\/h4\u003e\n\u003cp\u003eiris' compact profile and long-lasting battery make it easy to set up anywhere in your lab. The rechargeable lithium ion battery lasts for 3, 000 measurements, or 8 hours – well over a full day of use out in the field.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_with-USB-Stick.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eQuality data without the hassle.\u003c\/h4\u003e\n\u003cp\u003eExport your results with a USB drive or direct PC link organized by sample ID, method, or date range. Save data as a .pdf or .csv for maximum data integrity or flexibility – all without the use of specialized software.\u003c\/p\u003e\n\u003ch4\u003eMenu navigation that makes sense.\u003c\/h4\u003e\n\u003cp\u003eQuickly navigate between screens with custom keys, and access your favorite methods directly from the home screen with our “favorite methods” feature.\u003c\/p\u003e\n\u003ch4\u003eSort and share your data.\u003c\/h4\u003e\n\u003cp\u003eSave data as a .pdf or .csv for maximum data integrity or flexibility. Have the freedom to choose the file format that's best for you.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI801_Lab.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAll of your important information is easily visible.\u003c\/h4\u003e\n\u003cp\u003eWith a 6” display, the screen is large and easy to read. The high contrast makes every character on the display stand out even during outdoor use. The wide viewing angle allows for measurements to be seen from far away, so while working around the lab it is not necessary to hover over the meter to see the measurements.\u003c\/p\u003e\n\u003ch4\u003eZero resistance with a capacitive touch pad.\u003c\/h4\u003e\n\u003cp\u003eMenu buttons are part of the display. Built to be fully sealed and easy to clean, the meter recognizes key touches even through gloves.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI8010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePortable pH Meter - HI8010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eManual, two point, through trimmers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eManual from 0 to 100°C (32 to 212.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100°C (32 to 212.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1230B PEI body pH probe with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1 x 9V battery approx. 100 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185x82x53 mm (7.3x3.2x2.1”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e265 g (9.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI8010 is supplied with HI1230B pH electrode, calibration screwdriver, battery and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI8010\" target=\"_blank\" rel=\"noopener\"\u003ePortable pH Meter - HI8010\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871396036977,"sku":"HI801-02","price":403987.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/spectrophotometer-iris-front-hi801_1_1.jpg?v=1792646390"},{"product_id":"marine-alkalinity-checker-hc-hi755","title":"Marine Alkalinity Checker® HC - HI755","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI755 Checker®HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure alkalinity. Crucial in marine environments, alkalinity provides both the carbonate ion required for calcium carbonate skeletal regeneration of coral reefs, as well as a pH buffer against large changes in acidity. Designed as a more accurate alternative to chemical test kits, the HI755 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eInstructional Video\u003c\/h2\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI755\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI755\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 300 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 ppm (mg\/L) ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Method\u003c\/td\u003e\n\u003ctd\u003ecolorimetric method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI755 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, alkalinity reagent starter kit for 25 tests (1 bottle of alkalinity reagent), ­­­(1) battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI755\" target=\"_blank\" rel=\"noopener\"\u003eMarine Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI755\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871396102513,"sku":"HI755","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi755-checkerhc_front.jpg?v=1792646392"},{"product_id":"5-ml-syringe-for-mini-titrators-hi740236","title":"5 mL Syringe for Mini Titrators - HI740236","description":"\u003cp\u003eThe HI740236 replacement 5 mL plastic syringe allows for reliable titrant delivery and dosing for a variety of titrations. The syringe is easily replaced and can be connected in a matter of minutes. The HI845XX series of mini automatic titrators features a highly accurate titrant delivery system consisting of the 5 mL syringe driven by a dosing motor. The syringe,  along with the HI70500 tube set,  completes the replacement parts of the dosing system.\u003c\/p\u003e\n\u003cp\u003eThe HI740236 is used with the HI845XX series of mini titrators,  including:\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84500\u003c\/strong\u003e Sulfur Dioxide Mini Titrator for Wine Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84502\u003c\/strong\u003e Total Acidity Mini Titrator for Wine Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84529\u003c\/strong\u003e Titratable Acidity Mini Titrator for the Dairy Industry\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84530\u003c\/strong\u003e Titratable Acidity Mini Titrator for Water Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84531\u003c\/strong\u003e Titratable Alkalinity Mini Titrator for Water Analysis\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84532\u003c\/strong\u003e Titratable Acidity Mini Titrator for Fruit Juices\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI84533\u003c\/strong\u003e Formol Number Mini Titrator for Wines and Fruit Juices\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI740236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 5 mL Syringe for Mini Titrators - HI740236\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI740236\"\u003e5 mL Syringe for Mini Titrators - HI740236\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871397085553,"sku":"HI740236","price":1396.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi740236-1200by1200-rgb.jpg?v=1792646399"},{"product_id":"marine-alkalinity-checker-hc-calibration-check-set-hi755-11","title":"Marine Alkalinity Checker® HC Calibration Check Set - HI755-11","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI755-11 is a high-quality set of calibration standards that allows users to validate the Marine Alkalinity Checker® HC - HI755. The HI755-11 includes one sealed cuvette for zero ppm CaCO\u003csub\u003e3\u003c\/sub\u003e and one cuvette that is tinted to an equivalent 100 ±10 ppm CaCO\u003csub\u003e3\u003c\/sub\u003e sample @ 25℃. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI755-11 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI755-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI755-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eCuvettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI755-11\" target=\"_blank\" rel=\"noopener\"\u003eMarine Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI755-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871398134129,"sku":"HI755-11","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi755-11.jpg?v=1792646412"},{"product_id":"pool-and-spa-photometer-hi83326","title":"Pool and Spa Photometer - HI83326-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI83326 benchtop photometer measures 11 different key water quality parameters using 12 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eMade with the pool and spa industry in mind, a basic necessity of pool water treatment is to maintain the water in a safe and pleasant condition for the swimmers. In pool and spa water treatment, disinfection is essential to rid the pool of bacteria and control nuisance organisms like algae which may occur in the pool, spa, filtration equipment, or piping. There are a number of available disinfectant compounds including chlorine, bromine, and ozone. In order to achieve ideal water conditions, water requires testing on a daily and sometimes hourly basis to ensure there is enough residual disinfectant and to maintain pH levels. Equally important is calcium hardness and alkalinity; these levels should be monitored weekly to ensure the pool or spa water is well balanced to avoid corrosion and scale formation.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\n\u003cp\u003eThe HI83326 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the three wavelengths of light (525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eBacklit 128 x 64 Pixel Graphic LCD Display\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit graphic display allows for easy viewing in low light conditions\u003c\/li\u003e\n\u003cli\u003eThe 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement is taken after the countdown timer expires.\u003c\/li\u003e\n\u003cli\u003eCountdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAbsorbance mode\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHanna's exclusive CAL Check cuvettes for validation of light source and detector\u003c\/li\u003e\n\u003cli\u003eAllows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUnits of Measure\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAppropriate unit of measure along with chemical form is displayed along with reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eResult Conversion\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAutomatically convert readings to other chemical forms with the touch of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCuvette Cover\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAids in preventing stray light from affecting measurements\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eDigital pH Electrode Input\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH and temperature with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eSpace saving having a pH meter and photometer built into one meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button\u003c\/li\u003e\n\u003cli\u003eSample ID and User ID information can be added to a logged reading using alphanumeric keypad\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port\u003c\/li\u003e\n\u003cli\u003eData is exported as a .CSV file for use with common spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBattery Status Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eIndicates the amount of battery life left\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eError Messages\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePhotometric error messages include no cap, high zero, and standard too low\u003c\/li\u003e\n\u003cli\u003epH calibration messages include clean electrode, check buffer and check probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/method-selection.png\" alt=\"method selection\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMethod Selection\u003c\/h4\u003e\n\u003cp\u003eUsers can easily select any one of the 20 measurement methods via the dedicated METHOD button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/data-logging.png\" alt=\"data logging\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eData Logging\u003c\/h4\u003e\n\u003cp\u003eUp to 1000 measurement readings can be logged with user and sample ID and recalled for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-measurement-mode.png\" alt=\"ph measurement mode\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003epH Measurement Mode\u003c\/h4\u003e\n\u003cp\u003eSelecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdvanced Optical System\u003c\/h4\u003e\n\u003cp\u003eHI83326 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/OpticalSystem.jpg\" alt=\"photometer multiparameter optical\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHigh Efficiency LED Light Source\u003c\/h4\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch4\u003eHigh Quality Narrow Band Interference Filters\u003c\/h4\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (±1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch4\u003eReference Detector for a Stable Light Source\u003c\/h4\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the HI83326 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch4\u003eLarge Cuvette Size\u003c\/h4\u003e\n\u003cp\u003eThe sample cell of the HI83326 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch4\u003eFocusing Lens for Greater Light Yield\u003c\/h4\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI83326-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool and Spa Photometer - HI83326\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH\npH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH\npH electrode: 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH\npH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 ℃; 23.0 to 212.0 °F); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 4.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.003Abs @ 1.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 8.00 mg\/L (as Br\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003eHigh range: 0.00 to 5.00 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003eHigh Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±15% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003eHigh Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003eHigh Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eHigh Range: Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0.00 to 2.50 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±0.04 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: Adaptation of the Ascorbic Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 3 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003edigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e3 LEDs with 525 nm, 575 nm, and 610 nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e128 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003ecalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003elog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery \/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0 ℃ (32 to 122.0 °F); 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI83226 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI83326-01\" target=\"_blank\" rel=\"noopener\"\u003ePool and Spa Photometer - HI83326\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871411798385,"sku":"HI83326-02","price":105387.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83326-upper-angle-cover-closed_1.jpg?v=1792646512"},{"product_id":"marine-alkalinity-dkh-checker-hc-calibration-check-set-hi772-11","title":"Marine Alkalinity (dKH) Checker® HC Calibration Check Set - HI772-11","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI772-11 is a high-quality set of calibration standards that allows users to validate the Marine Alkalinity Checker® HC - HI772. The HI772-11 includes one sealed cuvette for zero dKH and one cuvette that is tinted to an equivalent 100 ±10 ppm CaCO\u003csub\u003e3\u003c\/sub\u003e dKH sample @ 25℃. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI772-11 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker-1-2-3.png\" alt=\"checker 123\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI77200P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI77200P 1500 mg\/L (ppm) TDS and pH 7.01 Sachets (20 x 20 mL, 10 each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e TDS calibration solution; standard calibration buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 7.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 20 (10 each)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Value @25°C\u003c\/td\u003e\n\u003ctd\u003e 1500 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI77200P\"\u003eHI77200P 1500 mg\/L (ppm) TDS and pH 7.01 Sachets (20 x 20 mL, 10 each)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871412191601,"sku":"HI772-11","price":2920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi772-11.jpg?v=1792646519"},{"product_id":"marine-alkalinity-checker-hc-reagents-25-tests-hi772-26","title":"Marine Alkalinity Checker® HC Reagents (25 Tests) - HI772-26","description":"\u003cp\u003eThe HI772-26 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with the Marine Alkalinity Checker® HC. These reagents follow the Colorimetric Method in which the reaction causes a distinctive range of colors from yellow to green to blue to develop. By simply adding the packet of HI772-26 reagent to the sample, the reaction will take place and the Marine Alkalinity Checkers will determine the concentration from the color that is produced. The results will be displayed in ppm of CaCO\u003csub\u003e3\u003c\/sub\u003e for the HI755 Checker or in dKH for the HI772 Checker . These reagents are designed to be used with samples that have an expected range of 0 to 300 ppm CaCO\u003csub\u003e3\u003c\/sub\u003e or 0.0 to 20.0 dKH.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI772-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Alkalinity (dKH) Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI772-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eCuvettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI772-11\" target=\"_blank\" rel=\"noopener\"\u003eMarine Alkalinity (dKH) Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI772-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871412224369,"sku":"HI772-26","price":1020.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi772-26.jpg?v=1792646519"},{"product_id":"freshwater-alkalinity-checker-hc-hi775","title":"Freshwater Alkalinity Checker® HC - HI775","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe HI775 Checker® HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure alkalinity. Present in varying concentrations in freshwater bodies, alkalinity, from carbonate and noncarbonate salts, provides a buffer against drastic pH changes in water. Used in the drinking water treatment process, the concentration of alkalinity dictates which chemicals are used and at what volumes, as well as protecting finished, potable drinking water in the distribution system. If being used to test samples where chlorine is present the HI93755-53 Chlorine remover is available so that any possibility of a chlorine interference is avoided. Designed as a more accurate alternative to chemical test kits, the HI775 provides quick, accurate results in four easy steps:\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Water Quality, Environmental, Education, Industrial\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFreshwater Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI775\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 ppm (mg\/L) ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ecolorimetric method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e81.5mm x 61mm x 37.5mm (3.2 in. x 2.4 in. x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI775 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, alkalinity reagent starter kit for 25 tests (1 bottle of alkalinity reagent), (1) 1 ml syringe and tip), ­­­ battery, instructions and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI775\" target=\"_blank\" rel=\"noopener\"\u003eFreshwater Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI775\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871412912497,"sku":"HI775","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi775-checkerhc-front.jpg?v=1792646521"},{"product_id":"freshwater-alkalinity-checker-hc-calibration-check-set-hi775-11","title":"Freshwater Alkalinity Checker HC® Calibration Check Set - HI775-11","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI775-11 is a high-quality set of calibration standards that allows users to validate the Freshwater Alkalinity Checker® HC - HI775 . The HI 775-11 includes one sealed cuvette for zero ppm CaCO\u003csub\u003e3\u003c\/sub\u003e and one cuvette that is tinted to an equivalent 100 ±10 ppm CaCO\u003csub\u003e3\u003c\/sub\u003e sample @ 25℃. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature controlled environment.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI727-11 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI775-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFreshwater Alkalinity Checker HC\u003csup\u003e®\u003c\/sup\u003e Calibration Check Set - HI775-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eCuvettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI775-11\" target=\"_blank\" rel=\"noopener\"\u003eFreshwater Alkalinity Checker HC\u003csup\u003e®\u003c\/sup\u003e Calibration Check Set - HI775-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871412945265,"sku":"HI775-11","price":2920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/generic-cuvett_29.jpg?v=1792646523"},{"product_id":"freshwater-alkalinity-checker-hc-reagents-25-tests-hi775-26","title":"Freshwater Alkalinity Checker® HC Reagents (25 Tests) - HI775-26","description":"\u003cp\u003eThe HI775-26 are high-quality reagents that are pre-measured, allowing for users to achieve fast and accurate measurements with their Freshwater Alkalinity Checker® HC. These reagents follow the Colorimetric Method in which the reaction causes a distinctive range of colors from yellow to green to blue to develop. By simply adding one drop of the Chlorine Remover to remove the chlorine interference, and subsequently adding 1 mL of the Alkalinity Reagent to the sample, the reaction will take place and the HI775 will determine the concentration from the color that is produced. The results will be displayed in ppm of CaCO\u003csub\u003e3\u003c\/sub\u003e . These reagents are designed to be used with samples that have an expected range of 0 to 500 ppm CaCO\u003csub\u003e3\u003c\/sub\u003e.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI775-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFreshwater Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC Reagents (25 Tests) - HI775-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eBottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e25 Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eColorimetric method. The reaction causes a distinctive range of colors from yellow to blue to develop. This meter has been developed to work with fresh water samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI775-26\" target=\"_blank\" rel=\"noopener\"\u003eFreshwater Alkalinity Checker\u003csup\u003e®\u003c\/sup\u003e HC Reagents (25 Tests) - HI775-26\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871412978033,"sku":"HI775-26","price":2920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi775-26.jpg?v=1792646523"},{"product_id":"pool-line-alkalinity-checker-hc-hi7754","title":"Pool Line Alkalinity Checker HC - HI7754","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker1234.jpg\" alt=\"How to use Hanna Checker Handheld Colorimeter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI7754 Pool Line Checker® Handheld Colorimeter is designed for the measurement of alkalinity in swimming pools, hot tubs, and spas. Alkalinity is a very important parameter in monitoring swimming pool water chemistry. Alkalinity is the buffering capacity of a solution to resist a pH change from the addition of an acid or base. This can be a challenge when using common forms of chlorine, in that, as a base when the chlorine is added the pH will increase. As the pH of the water increased above pH 7.4 the chlorine becomes predominately in the hypochlorite form instead of the hypochlorous acid as the pH decreases from pH 7.4. Hypochlorous acid is 100 times more effective as a sanitizer than the hypochlorite form. When water is low in alkalinity the pH will increase as the chlorine is added. When there is adequate alkalinity then as the chlorine is added the base is absorbed and the pH remains the same. Monitoring alkalinity is important in maintaining a stable pH of a swimming pool hot tub, or spa.\u003c\/p\u003e\n\u003cp\u003eThe contoured style of these Checkers’ fit in your palm and pocket perfectly and the large LCD is easy to read. The auto shut-off feature assures the battery life will not be drained if you forget to turn it off.\u003c\/p\u003e\n\u003cp\u003eTo perform a measurement the instrument a water sample is placed into a cuvette and the meter is zeroed. Next, a reagent is added that will react with alkalinity to produce a distinctive range of colors from yellow to greenish-blue. Last, place the vial into the Checker, press the button and read the results. It’s that easy. It is important to note that if chlorine is in the water sample to be tested then it is necessary to add HI937554-53 chlorine remover first before proceeding with the test.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003ePool Line Alkalinity Checker HC - HI7754\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 ppm (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 ppm ± 5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ecolorimetric Method. The reaction causes a distinctive range of colors from yellow to greenish blue to develop. This checker has been developed to work with fresh water samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter 10 minutes of non-use and 2 minutes after reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.3 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5mm (3.2 x 2.4 x 1.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7754 Checker HC is supplied with sample cuvettes with caps (2 pcs.), Alkalinity reagent starter (25 tests), 1.5VAAA battery (1 pc.), and instructions all packaged into a custom carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7754\" target=\"_blank\" rel=\"noopener\"\u003ePool Line Alkalinity Checker HC - HI7754\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871413010801,"sku":"HI7754","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7754.jpg?v=1792646524"},{"product_id":"pool-line-alkalinity-checker-hc-reagents-25-tests-hi7754-26","title":"Pool Line Alkalinity Checker HC Reagents (25 Tests) - HI7754-26","description":"\u003cp\u003eThe HI7754-26 are high-quality reagents that are pre-measured,  allowing for users to achieve fast and accurate measurements with their Freshwater Alkalinity Checker® HC. These reagents follow a colorimetric method in which the reaction causes a distinctive range of colors from yellow to green to blue to develop. By simply adding one drop of the Chlorine Remover to remove the chlorine interference,  and subsequently adding 1 mL of the Alkalinity Reagent to the sample,  the reaction will take place and the HI7754 Pool Line Checker HC for alkalinity will determine the concentration from the color that is produced. The results will be displayed in ppm of CaCO\u003csub\u003e3\u003c\/sub\u003e. These reagents are designed to be used with samples that have an expected range of 0 to 500 ppm CaCO\u003csub\u003e3\u003c\/sub\u003e.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7754-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Alkalinity Checker HC Reagents (25 Tests) - HI7754-26\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Colorimetric method. The reaction causes a distinctive range of colors from yellow to blue to develop. These reagents have been developed to work with fresh water samples.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7754-26\"\u003ePool Line Alkalinity Checker HC Reagents (25 Tests) - HI7754-26\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871413076337,"sku":"HI7754-26","price":2920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7754-26.jpg?v=1792646525"},{"product_id":"pool-line-alkalinity-checker-hc-calibration-check-set-hi7754-11","title":"Pool Line Alkalinity Checker HC Calibration Check Set - HI7754-11","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Soulution-Certificate-of-Analysis.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eHI7754-11 is a high-quality set of calibration standards that allows users to validate the performance HI7754 Pool Line Alkalinity Checker® HC. The HI7754-11 includes one sealed cuvette for zero ppm CaCO\u003csub\u003e3\u003c\/sub\u003e and one cuvette that is tinted to an equivalent 100 ±10 ppm CaCO\u003csub\u003e3 \u003c\/sub\u003esample @ 25℃. The calibration check set is produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eThe HI7754-11 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7754-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line Alkalinity Checker HC Calibration Check Set - HI7754-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7754-11 is supplied with HI7754-11A - alkalinity certified standard cuvette - A (1 pc.), HI7754-11B - alkalinity certified standard cuvette – B (1 pc.), certificate of analysis, and instruction for use.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7754-11\"\u003ePool Line Alkalinity Checker HC Calibration Check Set - HI7754-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871413141873,"sku":"HI7754-11","price":2920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7754-11.jpg?v=1792646525"},{"product_id":"aquaculture-photometer-hi83303","title":"Aquaculture Photometer - HI83303-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI83303 benchtop photometer measures 12 different key water quality parameters using 20 different methods. This photometer features an innovative optical system that uses LEDs, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eMade with the aquaculture industry in mind, the HI83303 is a comprehensive solution to maintaining optimal chemical and environmental conditions, preventing disease and increasing production. The HI83303 measures vital parameters such as alkalinity, calcium, nitrite, and phosphate. Alkalinity plays a part in a dynamic relationship with pH and CO\u003csub\u003e2\u003c\/sub\u003e concentrations, high alkalinity water lowers fluctuations in pH. The buffering capacity acts to store extra CO2 essential for photosynthesis in the ponds to produce oxygen. Maintaining calcium at certain levels is vital to proper fish growth and development. Excessive nitrite can be toxic to fish. When nitrite interacts with hemoglobin the iron becomes oxidized and the blood cell can no longer carry oxygen. Phosphate is essential to plant growth; too much phosphate in an aquaculture system can contribute to algal blooms decreasing dissolved oxygen vital for a successful ecosystem.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input allows the user to measure pH by a traditional glass electrode. The digital pH electrode has a built-in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built-in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\n\u003cp\u003eThe HI83303 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the five wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for educators to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eBacklit 128 x 64 Pixel Graphic LCD Display\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit graphic display allows for easy viewing in low light conditions\u003c\/li\u003e\n\u003cli\u003eThe 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement is taken after the countdown timer expires.\u003c\/li\u003e\n\u003cli\u003eCountdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eAbsorbance mode\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHanna's exclusive CAL Check cuvettes for validation of light source and detector\u003c\/li\u003e\n\u003cli\u003eAllows for the user to plot concentration versus absorbance for a specific wavelength for use with user-supplied chemistry or for teaching principles of photometry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eUnits of Measure\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAppropriate unit of measure along with chemical form is displayed along with reading\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eResult Conversion\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAutomatically convert readings to other chemical forms with the touch of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCuvette Cover\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAids in preventing stray light from affecting measurements\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eDigital pH Electrode Input\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH and temperature with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eSpace saving having a pH meter and photometer built into one meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button\u003c\/li\u003e\n\u003cli\u003eSample ID and User ID information can be added to a logged reading using alphanumeric keypad\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port\u003c\/li\u003e\n\u003cli\u003eData is exported as a .CSV file for use with common spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eBattery Status Indicator\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eIndicates the amount of battery life left\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eError Messages\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003ePhotometric error messages include no cap, high zero, and standard too low\u003c\/li\u003e\n\u003cli\u003epH calibration messages include clean electrode, check buffer and check probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/method-selection.png\" alt=\"method selection\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMethod Selection\u003c\/h4\u003e\n\u003cp\u003eUsers can easily select any one of the 20 measurement methods via the dedicated METHOD button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/data-logging.png\" alt=\"data logging\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eData Logging\u003c\/h4\u003e\n\u003cp\u003eUp to 1000 measurement readings can be logged with user and sample ID and recalled for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-measurement-mode.png\" alt=\"ph measurement mode\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003epH Measurement Mode\u003c\/h4\u003e\n\u003cp\u003eSelecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdvanced Optical System\u003c\/h4\u003e\n\u003cp\u003eHI83303 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/OpticalSystem.jpg\" alt=\"photometer multiparameter optical\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHigh Efficiency LED Light Source\u003c\/h4\u003e\n\u003cp\u003eA LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003ch4\u003eHigh-Quality Narrow Band Interference Filters\u003c\/h4\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (±1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003ch4\u003eReference Detector for a Stable Light Source\u003c\/h4\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the HI83303 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003ch4\u003eLarge Cuvette Size\u003c\/h4\u003e\n\u003cp\u003eThe sample cell of the HI83303 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003ch4\u003eFocusing Lens for Greater Light Yield\u003c\/h4\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI83303-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAquaculture Photometer - HI83303\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH\npH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH\npH electrode: 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH\npH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 ℃; 23.0 to 212.0 °F); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 4.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.003Abs @ 1.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\nSeawater: 0 to 300 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater:Low Range: 0.00 to 3.00 mg\/L\nMedium Range: 0.00 to 10.00 mg\/L\nHigh Range: 0.0 to 100.0 mg\/L\n(all as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003eLow and Medium Range: 0.01 mg\/L\nHigh Range: 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading\nMedium Range: ±0.05 mg\/L ±5% of reading\nHigh range: ±0.5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 400 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e)\nSeawater: 200 to 600 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater: ±10 mg\/L ±5% of reading\nSeawater: ±6% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater: Adaptation of the Oxalate method\nSeawater: Adaptation of the Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\nHigh range: 0.00 to 5.00 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading\nHigh Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0 to 600 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N)\nHigh Range: 0 to 150 mg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e)\nSeawater Ultra Low Range: 0 to 200 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 1 µg\/L; 1 mg\/L\nSeawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±20 µg\/L ±4% of reading\nHigh Range: ±4 mg\/L ±4% of reading\nSeawater\n±10 µg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eLow Range and Seawater: Adaptation of the EPA Diazotization method 354.1\nHigh Range: Adaptation of the Ferrous Sulfate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: 0.00 to 2.50 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\nHigh range: 0.0 to 30.0 mg\/L(as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e)\nSeawater Ultra Low Range: 0 to 200 µg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0.01 mg\/L; 0.1 mg\/L\nSeawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater\nLow Range: ±0.04 mg\/L ±4% of reading\nHigh Range: ±1 mg\/L ±4% of reading\nSeawater Ultra Low Range: ±5 µg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: Adaptation of the Ascorbic Acid method\nFreshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 5 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003edigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e128 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003ecalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003elog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery \/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0 ℃ (32 to 122.0 °F); 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97 mm (8.1 x 7.0 x 3.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI83303 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI83303-01\" target=\"_blank\" rel=\"noopener\"\u003eAquaculture Photometer - HI83303\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871415173489,"sku":"HI83303-02","price":91941.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83303-upper-angle-cover-closed_1.jpg?v=1792646546"},{"product_id":"high-range-titrant-for-titratable-alkalinity-in-water-mini-titrator-hi84531-51","title":"High Range Titrant for Titratable Alkalinity in Water Mini Titrator - HI84531-51","description":"\u003cp\u003eThe HI84531-51 is a 120 mL bottle of acidic titrant solution that is used for high range (300 to 4000 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e) determination of alkalinity in water.\u003c\/p\u003e\n\u003cp\u003eWater alkalinity is an expression of a water's acid-neutralizing capacity and it is determined by titration with standard acidic solutions. Alkalinity is an important parameter for control and treatment of potable water and wastewater because it indicates the buffering capacity of water,  or the ability to resist a pH change. The ability to resist large swings in pH results primarily from the presence of bicarbonates and carbonates. A low water alkalinity signifies that the water is susceptible to pH change,  while a high alkalinity indicates that water is able to resist a major change of pH.\u003c\/p\u003e\n\u003cp\u003eAlkalinity can be used to estimate levels of hardness or to determine the corrosive capacity of water. Alkalinity of surface water,  quantified by mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003eor meq\/L,  may be caused by carbonates,  bicarbonates,  hydroxides,  phosphates,  borates,  silicates,  or organic acid salts. Conventionally,  the water alkalinity is approximated as sum of components. Three types of alkalinities exist together to form total alkalinity (TA):\u003c\/p\u003e\n\u003ch5\u003eTA = OH\u003csup\u003e-\u003c\/sup\u003e + CO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e + HCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h5\u003e\n\u003cp\u003eOH\u003csup\u003e-\u003c\/sup\u003e = hydroxide alkalinity\u003c\/p\u003e\n\u003cp\u003eCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e = carbonate alkalinity\u003c\/p\u003e\n\u003cp\u003eHCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e = bicarbonate alkalinity\u003c\/p\u003e\n\u003cp\u003eTA = total alkalinity\u003c\/p\u003e\n\u003cp\u003eDifferent tests can be performed to determine the quantity of different alkalinities present. According to the Standard Methods of Water and Wastewater Analysis,  there are two options to determine water alkalinity:\u003c\/p\u003e\n\u003cp\u003e1) Strong alkalinity determination by titration of the water sample with strong acid solution to 8.3 pH (known as phenolphthalein alkalinity),  or\u003c\/p\u003e\n\u003cp\u003e2) Total alkalinity determination by titration of the water sample with strong acid solution to 4.5 pH (known as bromcresol green alkalinity).\u003c\/p\u003e\n\u003cp\u003eReplacement reagents required to operate the HI84531 include:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"185\"\u003e\n\u003ccol width=\"270\"\u003e\n\u003ccol width=\"270\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eLow Range - 30 to 400 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eHigh Range - 300 to 4000 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePump calibration standard\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-55\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-55\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eTitrant solution\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-50\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-51\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI84531-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e High Range Titrant for Titratable Alkalinity in Water Mini Titrator - HI84531-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e High Range Titrant for Titratable Alkalinity in Water Mini Titrator \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 120 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI84531-51\"\u003eHigh Range Titrant for Titratable Alkalinity in Water Mini Titrator - HI84531-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871417991537,"sku":"HI84531-51","price":2240.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/untitled_4.jpg?v=1792646582"},{"product_id":"pump-calibration-standard-for-titratable-alkalinity-in-water-mini-titrator-hi84531-55","title":"Pump Calibration Standard for Titratable Alkalinity in Water Mini Titrator - HI84531-55","description":"\u003cp\u003eThe HI84531-55 is a 230 mL bottle of pump calibration standard solution that is used for both low and high range determination of alkalinity in water.\u003c\/p\u003e\n\u003cp\u003eTitratable alkalinity in waters,  as performed on the HI84531 mini titrator,  utilizes a simple sample preparation,  a high quality titrant dosing pump,  potentiometric endpoint detector,  and automatic computations. To maintain the high precision of the titrator,  a simple pump calibration procedure is required. A change of measurement range requires a different titrant along with a pump recalibration. The pump calibration involves the analysis of a known volume of a known solution and compensates for changes in pump dosing that may occur due to many factors including tube stretching or aging. This procedure should be performed regularly with the HI84531-55 pump calibration solution to accurately determine alkalinity levels in water.\u003c\/p\u003e\n\u003cp\u003eReplacement reagents required to operate the HI84531 include:\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"210\"\u003e\n\u003ccol width=\"300\"\u003e\n\u003ccol width=\"300\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eLow Range - 30 to 400 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eHigh Range - 300 to 4000 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePump calibration standard\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-55\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-55\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eTitrant solution\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-50\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-51\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI84531-55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pump Calibration Standard for Titratable Alkalinity in Water Mini Titrator - HI84531-55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Pump Calibration Standard for Titratable Alkalinity in Water Mini Titrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI84531-55\"\u003ePump Calibration Standard for Titratable Alkalinity in Water Mini Titrator - HI84531-55\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871418057073,"sku":"HI84531-55","price":2240.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/untitled_4_1.jpg?v=1792646582"},{"product_id":"low-range-titrant-for-titratable-alkalinity-in-water-mini-titrator-hi84531-50","title":"Low Range Titrant for Titratable Alkalinity in Water Mini Titrator - HI84531-50","description":"\u003cp\u003eThe HI84531-50 is a 120 mL bottle of acidic titrant solution that is used for low range (30 to 400 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e) determination of alkalinity in water.\u003c\/p\u003e\n\u003cp\u003eWater alkalinity is an expression of a water's acid-neutralizing capacity and it is determined by titration with standard acidic solutions. Alkalinity is an important parameter for control and treatment of potable water and wastewater because it indicates the buffering capacity of water,  or the ability to resist a pH change. The ability to resist large swings in pH results primarily from the presence of bicarbonates and carbonates. A low water alkalinity signifies that the water is susceptible to pH change,  while a high alkalinity indicates that water is able to resist a major change of pH.\u003c\/p\u003e\n\u003cp\u003eAlkalinity can be used to estimate levels of hardness or to determine the corrosive capacity of water. Alkalinity of surface water,  quantified by mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e or meq\/L,  may be caused by carbonates,  bicarbonates,  hydroxides,  phosphates,  borates,  silicates,  or organic acid salts. Conventionally,  the water alkalinity is approximated as sum of components. Three types of alkalinities exist together to form total alkalinity (TA):\u003c\/p\u003e\n\u003ch5\u003eTA = OH\u003csup\u003e-\u003c\/sup\u003e + CO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e + HCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h5\u003e\n\u003cp\u003eOH\u003csup\u003e-\u003c\/sup\u003e = hydroxide alkalinity\u003c\/p\u003e\n\u003cp\u003eCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e = carbonate alkalinity\u003c\/p\u003e\n\u003cp\u003eHCO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e = bicarbonate alkalinity\u003c\/p\u003e\n\u003cp\u003eTA = total alkalinity\u003c\/p\u003e\n\u003cp\u003eDifferent tests can be performed to determine the quantity of different alkalinities present. According to the Standard Methods of Water and Wastewater Analysis,  there are two options to determine water alkalinity:\u003c\/p\u003e\n\u003cp\u003e1) Strong alkalinity determination by titration of the water sample with strong acid solution to 8.3 pH (known as phenolphthalein alkalinity),  or\u003c\/p\u003e\n\u003cp\u003e2) Total alkalinity determination by titration of the water sample with strong acid solution to 4.5 pH (known as bromcresol green alkalinity).\u003c\/p\u003e\n\u003cp\u003eReplacement reagents required to operate the HI84531 include:\u003cbr\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"210\"\u003e\n\u003ccol width=\"300\"\u003e\n\u003ccol width=\"300\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eLow Range - 30 to 400 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003eHigh Range - 300 to 4000 mg\/L as CaCO\u003csub\u003e3\u003c\/sub\u003e\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ePump calibration standard\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-55\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-55\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eTitrant solution\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-50\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eHI84531-51\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI84531-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Low Range Titrant for Titratable Alkalinity in Water Mini Titrator - HI84531-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Low Range Titrant for Titratable Alkalinity in Water Mini Titrator\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 120 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI84531-50\"\u003eLow Range Titrant for Titratable Alkalinity in Water Mini Titrator - HI84531-50\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871418089841,"sku":"HI84531-50","price":2240.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/untitled_1.png?v=1792646583"},{"product_id":"automatic-potentiometric-titrator-hi931","title":"Automatic Potentiometric Titrator - HI931-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eSuperior design for the busy lab.\u003c\/h4\u003e\n\u003cp\u003eThe Cycoloy® body is durable, heat-resistant, and resists staining. Dedicated menu buttons are part of the control panel making it fully sealed and easy to clean. A high contrast LCD display makes every character on the display stand out and the wide viewing angle allows measurements to be seen from any angle. The backlight is adjustable for your viewing preference and with a backlight saver option protects the display during periods of inactivity.\u003c\/p\u003e\n\u003ch4\u003eMaximize your workspace.\u003c\/h4\u003e\n\u003cp\u003eThis new generation of titrator features a 50% smaller footprint than the HI901 Automatic Titrator for maximum use of your benchtop lab space.\u003c\/p\u003e\n\u003ch4\u003eIntuitive User Interface\u003c\/h4\u003e\n\u003cp\u003eFunctional keys on the control panel that correspond to virtual keys on the display allow for simple and quick navigation between screens and menu. If you need additional information about a screen, simply press the dedicated button for help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Titration_screens.jpg\" alt=\"Titration Screens\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMultiple Titration Types\u003c\/h4\u003e\n\u003cp\u003ePaired with the right electrode, this potentiometric titrator can perform any number of standard titrations including pH and mV tests with fixed endpoints or single equivalence points.\u003c\/p\u003e\n\u003ch4\u003eReal-Time Graphing\u003c\/h4\u003e\n\u003cp\u003eA real-time titration curve can be viewed as the titration progresses. This feature is useful when new methods are tested or when a procedure requires optimization.\u003c\/p\u003e\n\u003ch4\u003ePassword Protection\u003c\/h4\u003e\n\u003cp\u003eAdministrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932_Burrette-Removal-Hand.jpg\" alt=\"Clip-Lock™ burette \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eExchangeable Burette System\u003c\/h4\u003e\n\u003cp\u003eWith Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.\u003c\/p\u003e\n\u003ch4\u003ePrecision Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eOur unmatched 40, 000-step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.\u003c\/p\u003e\n\u003ch4\u003eChemically Resistant Tubing\u003c\/h4\u003e\n\u003cp\u003eAspiration and dispensing tubes are constructed of chemically resistant PTFE plastic and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932_Holder-with-Probes.jpg\" alt=\"Flexible Electrode Holder\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFlexible Electrode Holder\u003c\/h4\u003e\n\u003cp\u003eThis electrode holder can hold up to 3 electrodes, 4 tubes, and 1 temperature probe. The holder is angled to concentrate the probes to the center for smaller beaker sizes. Use electrodes with different diameters when needed by changing the electrode guide.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Arm\u003c\/h4\u003e\n\u003cp\u003eFor a more compact design, the electrode holder is built directly into the titrator body. Height control adjustments are performed by simply pressing the press-to-release button makes. The electrode holder is reversible for use with large magnetic stirrers or oversize beakers.\u003c\/p\u003e\n\u003ch4\u003ePrecision Stirring\u003c\/h4\u003e\n\u003cp\u003eThe removable overhead stirrer has built-in speed control for instant feedback in order to maintain consistent stirring speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931_back.jpg\" alt=\"HI931 Back\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMultiple Measuring Modes\u003c\/h4\u003e\n\u003cp\u003eHI931 functions as a potentiometric titrator, pH meter, mV\/ORP meter, or ISE meter. Valuable laboratory bench space is saved, and multiple tests can be performed on one sample.\u003c\/p\u003e\n\u003ch4\u003eAnalytical Balance Interface\u003c\/h4\u003e\n\u003cp\u003eAnalytical balances with RS232 output can transfer the weight of a sample directly into the meter.\u003c\/p\u003e\n\u003ch4\u003ePrinter Interface\u003c\/h4\u003e\n\u003cp\u003eTitration reports can be printed directly from the titrator to a connected printer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI93X-baxk-pump-1200.jpg\" alt=\"Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Reagent Addition\u003c\/h4\u003e\n\u003cp\u003eA peristaltic pump may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition. The peristaltic pump can also be used to aspirate post-analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI93X-inside.jpg\" alt=\"Well and Gutters\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSmart Design for Safety\u003c\/h4\u003e\n\u003cp\u003eIn the event of reagent leakage an external gutter system protects the connections on the back of the meter and interior prevent any liquids from the internal electronics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI93X_USB.jpg\" alt=\"USB Storage\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCustomizable Analysis Reports\u003c\/h4\u003e\n\u003cp\u003eEach analysis report is fully customizable so users can ensure they are storing and filing the best data required for their application. New multi-select feature makes batch processing simple.\u003c\/p\u003e\n\u003ch4\u003eFlexible GLP Management\u003c\/h4\u003e\n\u003cp\u003eAll necessary GLP (Good Laboratory Practice) information is recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.\u003c\/p\u003e\n\u003ch4\u003eUSB Data Transfer\u003c\/h4\u003e\n\u003cp\u003eA conveniently located USB port on the side of the meter is used with a flash drive or direct connection to a PC for the transfer of titration methods, reports, and software upgrades. Reports can be converted to a LIMS friendly format with the use of our PC compatible software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI932-Right-Front-Raised.jpg\" alt=\"HI932 Advanced Automatic Potentiometric Titrator\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eNeed more?\u003c\/h4\u003e\n\u003ch4\u003eUpgrade to the HI932 Advanced Automatic Potentiometric Titrator for Multiple Sensor Inputs\u003c\/h4\u003e\n\u003ch4\u003eHI932 - Advanced Automatic Potentiometric Titrator\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI931001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003epH and mV precision simulator with LCD - HI931001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e±0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAll output values simulated at 25°C (77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e-1000 to 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 100 hours of use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 x 83 x 40 mm (7.1 x 3.3 x 1.6 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e255 g (9.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI931001 is supplied with HI7858\/1 BNC\/BNC coaxial cable.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI931001\" target=\"_blank\" rel=\"noopener\"\u003epH and mV precision simulator with LCD - HI931001\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871419761009,"sku":"HI931-02","price":754110.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-Angle-Low-Front-GLASS-5249x5249-f3f872c0-f0ca-4859-ad40-62f52e362e74.jpg?v=1792646608"},{"product_id":"alkalinity-reagents-300-tests-hi93755-03","title":"Alkalinity Reagents (300 tests) - HI93755-03","description":"\u003cp\u003eThe HI93755-03 are high quality reagents that are pre-mixed,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow a colorimetric method in which the reaction between alkalinity in a water sample and the reagent causes a green tint to be produced. By simply adding 1.0 mL of the HI93755-03 reagent to the sample,  the reaction will take place and a compatible photometer can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of alkalinity as calcium carbonate (CaCO\u003csub\u003e3\u003c\/sub\u003e). These reagents are designed to be used with samples that have an expected range of 0 to 500 mg\/L calcium carbonate.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCompatible Photometers Include:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHI83200\u003c\/li\u003e\n\u003cli\u003eHI83226\u003c\/li\u003e\n\u003cli\u003eHI83216\u003c\/li\u003e\n\u003cli\u003eHI83099\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93755-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Alkalinity Reagents (300 tests) - HI93755-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Colorimetric method. The reaction between causes a green tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93755-03\"\u003eAlkalinity Reagents (300 tests) - HI93755-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871432573297,"sku":"HI93755-03","price":9038.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93755-03.jpg?v=1792646688"},{"product_id":"alkalinity-reagents-100-tests-hi93755-01","title":"Alkalinity Reagents (100 tests) - HI93755-01","description":"\u003cp\u003eThe HI93755-01 are high quality reagents that are pre-mixed,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow a colorimetric method in which the reaction between alkalinity in a water sample and the reagent causes a green tint to be produced. By simply adding 1.0 mL of the HI93755-01 reagent to the sample,  the reaction will take place and a compatible photometer can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of alkalinity as calcium carbonate (CaCO\u003csub\u003e3\u003c\/sub\u003e). These reagents are designed to be used with samples that have an expected range of 0 to 500 mg\/L calcium carbonate.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCompatible Photometers Include:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHI83200\u003c\/li\u003e\n\u003cli\u003eHI83226\u003c\/li\u003e\n\u003cli\u003eHI83216\u003c\/li\u003e\n\u003cli\u003eHI83099\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93755-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Alkalinity Reagents (100 tests) - HI93755-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Colorimetric method. The reaction between causes a green tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93755-01\"\u003eAlkalinity Reagents (100 tests) - HI93755-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871433720177,"sku":"HI93755-01","price":3203.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93755-0.jpg?v=1792646703"},{"product_id":"ph-alkalinity-free-chlorine-total-chlorine-and-cyanuric-acid-photometer-hi97104-meter-only","title":"pH,  Alkalinity, Free Chlorine, Total Chlorine, and Cyanuric Acid Photometer - HI97104-meter only","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eChlorine is a common chemical used by many due to is disinfection properties. Free chlorine can exist in two forms and which form is present is based on the pH. At pH less than 7.6 the predominate form is hypochlorous acid (HOCl) while at pH greater than 7.6 the hypochlorite (OCl\u003csup\u003e-\u003c\/sup\u003e) form becomes predominate. This is very important when it comes to preventing biological growth in water or keeping a swimming pool safe since hypochlorous acid is 100 times more effective as a sanitizer. Total chlorine represents both the free chlorine and combined chlorine present. Combined chlorine is the chlorine bound to nitrogen substances such as ammonia. In swimming pools combined chlorine that we can smell and is irritating to the eyes. The free chlorine measurement is subtracted from the total chlorine measurement in order to know how much combined chlorine is present. HI97104 is designed to measure swimming pool key water quality paramters. These parameters,  in addition to chlorine,  are pH,  alkalinity,  and cyanuric acid.\u003c\/p\u003e\n\u003cp\u003eThe HI97104 has an innovative optical system that offers superior performance in accuracy,  repeatability,  and the short amount of time it takes to perform a measurement. This compact,  waterproof meter is extremely user friendly with a tutorial mode that walks the user graphically,  step by step,  in performing a measurement. The use of a backlit dot matrix LED allows the use of virtual keys which makes the operation of the meter very intuitive including selecting different methods,  reviewing GLP data,  recalling the last 50 measurements,  and customizing the meter to user preferences\u003c\/p\u003e\n\u003cp\u003eHI97104 is completely waterproof including the cuvette holder that is designed with ridges to protect the optical path from getting scratched by the cuvette and a gasketed battery compartment that holds three common AA batteries. The compact design fits comfortable in the hand for use in the field or on a table for benchtop use. The LCD is 71 mm (2.75\") by 37 mm (1.6\") and is backlit for easy viewing under all conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/PHOTOMETER-OPTICAL-SYSTEM.jpg\" alt=\"photometer optical system\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cul\u003e\u003cli\u003eLED that generates very little heat\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e8 nm narrowband interference filter that is accurate to ±1 nm and offers 25% increase in light efficiency.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eReference detector that modulates the voltage to LED for consistent light output.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eA concave focusing lens that reduces errors from imperfections in the cuvette\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-Screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Cal_Check.jpg\" alt=\"CAL Check HI97700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCAL Check\u003c\/h4\u003e\n\u003cp\u003eAdvanced features including CAL-Check to verify performance,  GLP for last calibration date,  setup options and the ability to see all accessories used with the meter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/tutorial.jpg\" alt=\"tutorial mode HI97104\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eTutorial Mode\u003c\/h4\u003e\n\u003cp\u003eWhen enabled,  the tutorial mode will guide the user step by step through the measurement process .\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Method_Selection.jpg\" alt=\"method option\" width=\"300\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMethod Options\u003c\/h4\u003e\n\u003cp\u003eChoice of powder or economical liquid reagents for chlorin measurments.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHI97104 FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch5\u003eStable Light Source:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe internal reference system of the HI97104 photometer compensates for any drifts due to power fluctuations or ambient temperature changes. With a stable source of light the readings are fast and stable between your blank (zero) measurement and sample measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh Efficiency Light Source:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eLED light sources offer superior performance compared to tungsten lamps. LEDs have a much higher luminous efficiency,  providing more light while using less power. They also produce little heat,  which could otherwise affect electronic stability.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh Quality Filters:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eImproved optical filters ensure greater wavelength accuracy and allow a brighter,  stronger signal to be received. The end result is higher measurement stability and less wavelength error.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGreater Light Yield:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eA focusing lens collects all of the light that exits the cuvette,  eliminating errors from imperfections and scratches that may be present in the glass. The use of the convex lens reduces the need for indexing cuvettes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eCAL Check Functionality:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna’s exclusive CAL Check feature allows for performance verification and calibration of the meter using NIST traceable standards. Our CAL Check standard vials are developed to simulate a specific absorbance value at each wavelength to verify the accuracy of subsequent readings.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMulitple Measurement Methods:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eUsers can select the use of powder reagents supplied in packets or the use of low cost liquid reagents supplied in a dropper bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBuilt-in Reaction Timer:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eWaiting the proper reaction time is of key importance when performing colorimetric measurements. The countdown timer displays the time remaining until a measurement will be taken,  ensuring consistent results between sample measurements and users.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eLarge Cuvette Size:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe sample cell of the HI97104 fits a round,  glass cuvette with a 25 mm path length. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution,  ensuring accurate measurements even in low absorbance samples.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eIntuitive Dot Matrix Display:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe HI97104 is designed with a backlit,  graphic LCD. With virtual keys,  a battery status indicator,  and error messages. Users will find the meter interface intuitive and easy to read. A dedicated help key provides information relating to the current meter operation,  and can be used at any stage in the setup or measurement process to show contextual help.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-off Protection:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe meter uses three common AA batteries that allow for about 800 measurements to be taken. The auto-off feature automatically shuts off the meter after 15 minutes of inactivity in order conserve battery life.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI97104\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH, Alkalinity, Free Chlorine, Total Chlorine, and Cyanuric Acid Photometer - HI97104-meter only\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 6.5 to 8.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003e phenol red method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±5 mg\/L ±5% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003e colorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.03 mg\/L ±3% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.03 mg\/L ±3% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e adaptation  of  US  EPA  method  330.5,  DPD Colorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 80 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±1 mg\/L ±15% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003e Adaptation of turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e light emitting diode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003e silicon photocell with narrow band interference filter @ 525 nm and 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e 8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±1.0 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003e round 24.6 mm diameter (22 mm inside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e 128 x 64 pixel B\/W LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Points Stored\u003c\/td\u003e\n\u003ctd\u003e 50 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5 V AA Alkaline (3 pcs.) \/ \u0026gt; 800 measurements (without backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e after 15 minutes of inactivity(30 minutes before a READ measurement)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50 °C (32 to 122 °F);\u003cbr\u003e0 to 100% RH\u003cbr\u003eIP67, floating case\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 380 g (13.4 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 142.5 x 102.5 x 50.5 mm (5.6 x 4.0 x 2.0 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI97104 is supplied with cuvettes (2), caps (2), plastic inserts for cuvettes (2), 1.5V AA batteries (3), instruction manual, and instrument quality certificate. \/\u003cbr\u003eKit version: HI97104C is supplied with CAL-Check standards, cuvettes (2), caps (2), plastic inserts for cuvettes (2), scissors, cuvette cleaning cloth, 1.5V AA batteries (3), instruction manual, and instrument quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI97104\"\u003epH, Alkalinity, Free Chlorine, Total Chlorine, and Cyanuric Acid Photometer - HI97104-meter only\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871438668145,"sku":"HI97104","price":45928.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi97104_1.jpg?v=1792646743"},{"product_id":"marine-alkalinity-dkh-checker-hc-hi772","title":"Marine Alkalinity (dKH) Checker® HC - HI772","description":"\u003cp\u003eThe HI772 Checker®HC (Handheld Colorimeter) provides a simple, accurate and cost-effective way to measure alkalinity in degrees of calcium hardness, commonly abbreviated as dKH. Critical to marine environments, alkalinity not only provides the carbonate ion required for calcium carbonate skeletal regeneration of coral reefs, but it also acts as a pH buffer against large changes in acidity. Designed as a more accurate alternative to chemical test kits, the HI772 provides quick, accurate results in four easy steps:\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eEasier to use and more accurate than chemical test kits\u003c\/li\u003e\n\u003cli\u003eDedicated to a single parameter\u003c\/li\u003e\n\u003cli\u003eSmall size, big convenience\u003c\/li\u003e\n\u003cli\u003eIdeal for: Aquaculture \u0026amp; Aquariums, Water Quality\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eVideo\u003c\/h2\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI772\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Alkalinity (dKH) Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI772\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 dKH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 dKH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 dKH ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Alkalinity Method\u003c\/td\u003e\n\u003ctd\u003ecolorimetric method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003eLED @ 610 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e(1) 1.5V AAA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003eafter ten minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e64 g (2.25 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e86.0 mm x 61.0 mm x 37.5 mm (3.4 in. x 2.4 in. x 1.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI772 Checker\u003csup\u003e®\u003c\/sup\u003e is supplied with (2) sample cuvettes with caps, alkalinity reagent starter kit for 25 tests (1 bottle of alkalinity reagent), (1) 1 ml syringe and tip, ­­­ battery, instructions, and quick start guide.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI772\" target=\"_blank\" rel=\"noopener\"\u003eMarine Alkalinity (dKH) Checker\u003csup\u003e®\u003c\/sup\u003e HC - HI772\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871457313137,"sku":"HI772","price":6371.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi772-checkerhc_front.jpg?v=1792646939"},{"product_id":"edge-multiparameter-ph-meter-230v-hi2020","title":"edge® Multiparameter pH Meter, 230V - HI2020-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eedge® is packed with many cutting edge features to ensure accuracy and usability.\u003c\/p\u003e\n\u003ch5\u003eDigital Electrodes\u003c\/h5\u003e\n\u003cp\u003eedge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.\u003c\/p\u003e\n\u003ch5\u003eSensor Check\u003c\/h5\u003e\n\u003cp\u003eWhen used with Hanna’s pH electrodes equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. During calibration, Sensor Check checks the state of the junction. The reference junction is also evaluated and reported on the display.\u003c\/p\u003e\n\u003ch5\u003e3.5 mm Probe Input\u003c\/h5\u003e\n\u003cp\u003ePlugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.\u003c\/p\u003e\n\u003ch5\u003eWall Mount\u003c\/h5\u003e\n\u003cp\u003eUsing the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.\u003c\/p\u003e\n\u003ch5\u003eCradle and Electrode Holder\u003c\/h5\u003e\n\u003cp\u003eedge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.\u003c\/p\u003e\n\u003ch5\u003eTwo USB Ports\u003c\/h5\u003e\n\u003cp\u003eedge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.\u003c\/p\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cp\u003eedge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.\u003c\/p\u003e\n\u003ch5\u003eTwo Operating Modes\u003c\/h5\u003e\n\u003cp\u003eedge can be used in Extended or Basic Operating Modes. Extended Mode enables all features available while the Basic Mode reduces the amount of features to a very simple operation. For example, in extended mode edge offers 5 point calibration with 2 custom buffers while in basic mode calibration can only be performed to 3 points with 5 preprogrammed buffers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/45ms0xpvk5?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/8c55539d67ea1d24de589d4f7ab0d40faf95a394.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI2020-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e® Multiparameter pH Meter - HI2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 pH, 0.01 pH, 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.002 pH, ±0.01 pH, ±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eGlass and reference junction diagnostics ( HI 11311 \u0026amp; HI 12301 only), out of calibration range , probe condition, response time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm, 30.0 to 299.9 µS\/cm, 300 to 2999 µS\/cm, 3.00 to 29.99 mS\/cm, 30.0 to 200.0 mS\/cm, up to 500.0 mS\/cm (absolute EC)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm, 0.1 µS\/cm, 1 µS\/cm, 0.01 mS\/cm, 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point offset calibration (0.00 µS\/cm in air), 1 point slope calibration in EC standard 84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm and 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 ppm (mg\/L), 15.0 to 149.9 ppm (mg\/L), 150 to 1499 ppm (mg\/L), 1.50 to 14.99 g\/L, 15.0 to 100.0 g\/L, up to 400.0 g\/L (absolute TDS)**, with 0.80 conversion factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g\/L, 0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0% NaCl***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point with HI 7037L 100% NaCl sea water standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e2.00 to 42.00 PSU***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 80.0 g\/L***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 ppm (mg\/L), 0.0 up to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 digit, ±1.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eone or two points at 0% (HI 7040 solution) and 100% (in air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC: 0 to 50 ºC; 32.0 to 122.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (with 1 g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e-500 to 4000 m (with 100 m resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 ºC, -4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C, ±0.9 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI11310 pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eManual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 1000*** records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 micro USB port for charging and PC connectivity, 1 USB port for storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eBuilt-in rechargeable battery with up to 8 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7mm (8” x 5.5” x 0.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g (8.82 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI2020 pH kit includes: HI11310 glass body, refillable pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI2020-01\" target=\"_blank\" rel=\"noopener\"\u003e® Multiparameter pH Meter - HI2020\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461736817,"sku":"HI2020-02","price":69984.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sides-png-700_C3_97700.png?v=1792646983"},{"product_id":"advanced-automatic-potentiometric-titrator-hi932","title":"Advanced Automatic Potentiometric Titrator - HI932","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eTake your testing to the next level with our Automatic Titrator (HI932) and set a higher standard for quality at your laboratory or business.\u003c\/p\u003e\n\u003cp\u003eWe’ve meticulously designed this titrator to not just help you meet industry and application requirements, but to surpass them altogether.\u003c\/p\u003e\n\u003cp\u003eOur Automatic Titrator is durable and built to withstand the harsh chemicals used during titrations. Up for the task at hand, this titrator unit is manufactured with a strong Cycoloy® body and chemically resistant PTFE tubing.\u003c\/p\u003e\n\u003cp\u003eWith its compact size, our Automatic Titrator requires less benchtop space and fits seamlessly into any testing environment.\u003c\/p\u003e\n\u003cp\u003eAt Hanna Instruments, we understand that purchasing an automatic titration system is a big decision and there are a multitude of considerations to make beforehand. Our team of experts are here to answer any questions that you may have and can help you determine the best solution for your application and testing requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eExperience our Automatic Titrator\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-burettes-minimal-titrant.webp\" alt=\"Measure with precision\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMeasure with precision\u003c\/h4\u003e\n\u003cp\u003eGet accurate and consistent results at just the push of a button. Our Automatic Titrator is built with a 40,000 step dosing pump, capable of dosing extremely small volumes of titrant and achieving an exact endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/attain-repeatable-results-300by200.webp\" alt=\"Attain repeatable results\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAttain repeatable results\u003c\/h4\u003e\n\u003cp\u003eSeveral shift changes can occur at labs. Our Automatic Titrator arrives with preprogrammed methods which can be optimized to match your testing needs. Users can perform and replicate tests the same way each time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/decisions-300by200-kk.webp\" alt=\"Meet quality standards\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMeet quality standards\u003c\/h4\u003e\n\u003cp\u003eAdhering to strict requirements is an absolute must. Be ready with our Automatic Titrator! Gain traceability and produce customizable analysis reports. Store required data for each application and record all GLP information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-decision-2.webp\" alt=\"Make decisions and adjustments on the spot\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMake decisions and adjustments on the spot\u003c\/h4\u003e\n\u003cp\u003eStart taking control of your testing with our Automatic Titrator. By testing in-house, you can avoid delays and stay proactive. Discover potential quality issues quickly, take corrective action, and implement changes when needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-free-time.webp\" alt=\"Free up time and increase productivity\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFree up time and increase productivity\u003c\/h4\u003e\n\u003cp\u003eLet our Automatic Titrator do the bulk of the work for you! While a titration is running, you can  focus on other important tasks simultaneously. Cross more things off your priority list and improve overall efficiency.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-methods.webp\" alt=\"Test confidently and eliminate the hassle\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eTest confidently and eliminate the hassle\u003c\/h4\u003e\n\u003cp\u003eUser-friendly, our Automatic Titrator makes testing simple and convenient. Don't worry about getting lost or overloaded with information. This unit is equipped with intuitive screens and menus for easy navigation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-industries.webp\" alt=\"Which industries use Automatic Titrators?\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eWhich industries use Automatic Titrators?\u003c\/h4\u003e\n\n\u003cul\u003e\n\u003cli\u003eFood\u003c\/li\u003e\n\u003cli\u003eBeverage Manufacturing\u003c\/li\u003e\n\u003cli\u003eLaboratory\u003c\/li\u003e\n\u003cli\u003eEducation and Research\u003c\/li\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003ePetrochemical\u003c\/li\u003e\n\u003cli\u003eMunicipalities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eApplications and standard methods\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px; max-height: 560px; overflow-y: auto;\"\u003e\n\u003ctable data-filter-table data-filter-columns=\"0,1,2,3\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eIndustry\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSample\u003c\/th\u003e\n\u003cth\u003eStandard Methods\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkali, Free \u0026amp; Total\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eMineral Carbonized Concrete\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Food, Beverage, Industrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eAmine Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D6979\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eSurfactants, Anionic\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eAscorbic Acid\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eBoric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Cleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eBoron Trioxide\u003c\/td\u003e\n\u003ctd\u003eTreating Solutions, Treated Wood\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eSurfactants, Cationic\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003eASTM D5806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eCaustic and Aluminum\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eChloride\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eChloride\u003c\/td\u003e\n\u003ctd\u003eAnimal Feed\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government, Food, Beverage, Water Treatment\u003c\/td\u003e\n\u003ctd\u003eChloride\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eSodium Cyanide\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eDegree of Neutralization\u003c\/td\u003e\n\u003ctd\u003eHair Fixatives\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eFluoride\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eFormol Number\u003c\/td\u003e\n\u003ctd\u003eWines, Juices\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eFree Fatty Acids\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Oils\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eGlutaraldehyde\u003c\/td\u003e\n\u003ctd\u003eDisinfectants\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Calcium (ISE)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Total \u0026amp; Calcium (ISE)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Calcium (Photometric)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Total \u0026amp; Calcium (Photometric)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eChromium, Hexavalent\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eHydrazine\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eHydrogen Peroxide\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003ePeracetic Acid\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eHydroxyl Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSodium Hypophosphite\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Cleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIron, Ferric\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIron, Ferrous\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIron, Total\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eLime\/Calcium Hydroxide\u003c\/td\u003e\n\u003ctd\u003eLimestone, Quicklime, Hydrated Lime\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIsocyanate (NCO)\u003c\/td\u003e\n\u003ctd\u003ePolyurethane Raw Materials\u003c\/td\u003e\n\u003ctd\u003eISO 14896; ASTM D5155; ASTM D2572\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNeutralization\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNickel Chloride\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNickel\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNitric Acid\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNitric Acid and Hydrofluoric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNitric Acid, Hydrofluoric Acid, and Titanium\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eOrganic Chlorides\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eASTM D4929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Food, Beverage\u003c\/td\u003e\n\u003ctd\u003ePeroxide Value\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Oils\u003c\/td\u003e\n\u003ctd\u003eAOAC 965.33; AOCS Cd 8b-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003ePhosphoric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Cleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eReducing Sugars\u003c\/td\u003e\n\u003ctd\u003eWines, Juices\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eResin\u003c\/td\u003e\n\u003ctd\u003eHair Fixatives\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government, Food, Beverage\u003c\/td\u003e\n\u003ctd\u003eSalt \/ Sodium Chloride\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government, Food, Beverage\u003c\/td\u003e\n\u003ctd\u003eSodium Bicarbonate\u003c\/td\u003e\n\u003ctd\u003eFoodstuffs, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSodium Dichromate\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSodium Hypochlorite \/ Bleach\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents, Water\/Wastewater\u003c\/td\u003e\n\u003ctd\u003eASTM D2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide, Free\u003c\/td\u003e\n\u003ctd\u003eWines, Juices, Beverages\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide, Total\u003c\/td\u003e\n\u003ctd\u003eWines, Juices, Beverages\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSulfuric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSulfuric Acid and Aluminum\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eThiocyanate\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTin\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eTitratable Acidity\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Acid Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Acid Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D974\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Base Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D2896\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Base Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D4739\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Inorganic Carbon\u003c\/td\u003e\n\u003ctd\u003eDigestate\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eVolatile Fatty Acids\u003c\/td\u003e\n\u003ctd\u003eDigestate\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eVolatile Acidity\u003c\/td\u003e\n\u003ctd\u003eWines, Juices, Beverages\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eZinc\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eTailor to your testing needs\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(260px, 1fr)); gap: 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"border: 1px solid #c9d6e6; border-radius: 8px; padding: 20px; background: #f7f9fc;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCan you customize titration methods?\u003c\/h4\u003e\n\u003cp style=\"margin: 0;\"\u003eYes, of course! With our Automatic Titrator, you can modify titration methods to suit your application requirements. Titrate for a variety of published methods and store up to 100 user-defined, standard titration, and direct measurement methods\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c9d6e6; border-radius: 8px; padding: 20px; background: #f7f9fc;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAre you able to perform different titration types?\u003c\/h4\u003e\n\u003cp style=\"margin: 0;\"\u003eYes, this is possible! Pair with the right electrode and complete numerous standard and back titrations as well as direct pH, ORP, and ion-selective readings\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c9d6e6; border-radius: 8px; padding: 20px; background: #f7f9fc;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eWhat is the linked methods function?\u003c\/h4\u003e\n\u003cp style=\"margin: 0;\"\u003eAvailable for certain applications, this unique approach saves you time and allows you to measure two parameters in one sample with a single method.  One sample + One method = Two results\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/network-box-pagehi932-b.jpg\" alt=\"Pair your titrator with our Network Box\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eEnsure data integrity\u003c\/h4\u003e\n\u003ch5\u003ePair your titrator with our Network Box\u003c\/h5\u003e\n\n\u003cul\u003e\n\u003cli\u003eAllows our Automatic Titrator (HI932) to integrate with a Laboratory Information Management System (LIMS) via a secure Ethernet connection for text\/PDF data exchange\u003c\/li\u003e\n\u003cli\u003eSupports USB printing and enables Titrator generated files including methods, reports, and data logs to be printed\u003c\/li\u003e\n\u003cli\u003eWith FTPS and SMB network transfer capabilities, data files can be moved from the Titrator to network storage\u003c\/li\u003e\n\u003cli\u003eA secure TLS connection encrypts transferred data, ensuring data integrity\u003c\/li\u003e\n\u003cli\u003eOur Network Box is a Trusted Platform Module (TPM) 2.0 device and provides hardware-based security for key storage, encryption, and platform integrity\u003c\/li\u003e\n\u003cli\u003eProvides upgrade support and can install updates to patch vulnerabilities and add features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, max(440px, calc((100% - 48px) \/ 2))), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932-Flexible-electrode-holder.jpg\" alt=\"Modifiable electrode holder\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eModifiable electrode holder\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHold up to three electrodes, four tubes, and one temperature probe\u003c\/li\u003e\n\u003cli\u003eChange the electrode guide to use electrodes with different diameters\u003c\/li\u003e\n\u003cli\u003eCreate the best tube alignment for titrations with a rotating electrode holder\u003c\/li\u003e\n\u003cli\u003eGain extra space and accommodate larger beakers by reversing the electrode holder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931HI932-adjustable.jpg\" alt=\"Adjustable arm\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAdjustable arm\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGet the versatility you need and use the press-to-release button for simple height control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/stirrer-689by460.jpg\" alt=\"Convenient stirrer\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConvenient stirrer\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSwap the overhead stirrer with a stir plate and stir bar for access to smaller volume titrations\u003c\/li\u003e\n\u003cli\u003eEnsure consistent stirring with built-in speed control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932-removable-burrett.jpg\" alt=\"Exchangeable burette system\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eExchangeable burette system\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSave time with our Clip-Lock™ burette system. Exchange titrants and reagents in just a few seconds and prevent cross-contamination\u003c\/li\u003e\n\u003cli\u003eFasten the Clip-Lock easily and listen for an audible clicking sound to signal when it is securely in place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-burettes-minimal-titrant.jpg\" alt=\"Automatic reagent addition\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic reagent addition\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProgram a peristaltic pump or a second burette to dispense reagent prior to titration or a direct measurement. This prevents human-error, incorrect volumes or simply forgetting to add reagent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi922.jpg\" alt=\"Add an Autosampler\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eBetter together\u003c\/h4\u003e\n\u003ch5\u003eAdd an Autosampler\u003c\/h5\u003e\n\u003cp\u003eImprove your titrations with this duo! Our Automatic Titrator (HI932) and Autosampler (HI922) join forces to provide you with the ultimate testing experience. \u003c\/p\u003e\n\u003cp\u003eOur Autosampler (HI922) interfaces directly with this titrator unit for easy, fast, and accurate testing. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen paired together, you can:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerform titration methods in sequence\u003c\/li\u003e\n\u003cli\u003eTitrate for multiple samples. Run automated sample titrations consecutively using a 16 or 18 sample tray\u003c\/li\u003e\n\u003cli\u003eStay informed with status indicator lights. These change color to notify you which testing stage you are in or alert you to a problem\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/support-hi932-page.jpg\" alt=\"We're here for you\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eWe're here for you\u003c\/h4\u003e\n\u003cp\u003eWhen you invest in a titrator with Hanna, you gain an entire team of experts ready to support you and your testing needs. \u003cbr\u003e\u003cbr\u003eWe work with you every step of the way to ensure your testing success. From titrator installation and training to method customization and preventative maintenance, we’ve got you covered. \u003cbr\u003e\u003cbr\u003eGet peace of mind and keep your titrator operating at optimal performance! Ask us about our titrator service plan options.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/manual.jpg\" alt=\"Tired of manual titrations? Make the switch\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eTired of manual titrations? Make the switch\u003c\/h4\u003e\n\u003cp\u003eWe understand that making the move from manual to automatic titration can seem overwhelming at first. At Hanna, we make this transition easy. \u003cbr\u003e\u003cbr\u003eNot sure if you are ready? Check out our top 5 reasons for why you should automate and test with a titrator.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eResources\u003c\/h2\u003e\n\u003cdiv data-desc-tabs style=\"margin: 0 0 48px;\"\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eWhat's Included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced Automatic Potentiometric Titrator (HI932)\u003c\/li\u003e\n\u003cli\u003ePump assembly\u003c\/li\u003e\n\u003cli\u003eBurette assembly (burette with 25 mL syringe, aspiration tube with fitting and protection tube, dispensing tube with dispensing tip, protection tube, and tube guide, tube locks, tool for burette cap removal, and light spectrum protection screen)\u003c\/li\u003e\n\u003cli\u003eElectrodes holder and stirrer (electrode holder, overhead stirrer, propellers (3 pcs.), and support rod)\u003c\/li\u003e\n\u003cli\u003eBurette blank support\u003c\/li\u003e\n\u003cli\u003ePump and burette locking screws with plastic head\u003c\/li\u003e\n\u003cli\u003eTemperature sensor (1 pc.)\u003c\/li\u003e\n\u003cli\u003eShorting cap (1 pc.)\u003c\/li\u003e\n\u003cli\u003ePower adapter (1 pc.)\u003c\/li\u003e\n\u003cli\u003eUSB flash drive (1 pc.)\u003c\/li\u003e\n\u003cli\u003eUSB cable (1 pc.)\u003c\/li\u003e\n\u003cli\u003eHI900 PC application (installation kit on USB flash drive)\u003c\/li\u003e\n\u003cli\u003eInstruction manual (1 pc.)\u003c\/li\u003e\n\u003cli\u003eQuality certificate (1 pc.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eSecurity Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the titrator unit. Determine appropriate permission settings for each user, administrator or non-administrator level, to prevent unwanted edits or changes to titration method options and results\u003c\/li\u003e\n\u003cli\u003eAdministrators can set a PIN code on the titrator unit to protect against unauthorized access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eReporting Capabilities\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eStore up to 100 titration and pH\/mV\/ISE reports\u003c\/li\u003e\n\u003cli\u003eProduce customizable analysis reports and store the required data for each application. The multi-select option also makes batch processing simple\u003c\/li\u003e\n\u003cli\u003eRecord all required GLP (Good Laboratory Practice) information automatically for each sample. This includes sample identification, company and operator name, date, time, electrode ID codes, and calibration data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eConnection Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eExport and transfer data such as titration methods, reports, and software updates via a USB flash drive or PC\u003c\/li\u003e\n\u003cli\u003eConnect an analytical balance to the titrator unit for automatic sample weight entry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis Type\u003c\/td\u003e\n\u003ctd\u003eStandard titration (Standardization, Fixed pH \/ mV, Equivalence point pH \/ mV)\u003cbr\u003eBack titration\u003cbr\u003eDirect reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndpoint Mode\u003c\/td\u003e\n\u003ctd\u003eFixed mV\u003cbr\u003eFixed pH\u003cbr\u003emV equivalence point (up to 5 points, 1\u003csup\u003est\u003c\/sup\u003e or 2\u003csup\u003end\u003c\/sup\u003e derivative)\u003cbr\u003epH equivalence point (Up to 5 points, 1\u003csup\u003est\u003c\/sup\u003e or 2\u003csup\u003end\u003c\/sup\u003e derivative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Size\u003c\/td\u003e\n\u003ctd\u003e5 mL, 10 mL, 25 mL, 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Flow Rate\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.3 mL to 2 x burette volume per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.005 mL (5 mL burette)\u003cbr\u003e±0.010 mL (10 mL burette)\u003cbr\u003e±0.025 mL (25 mL burette)\u003cbr\u003e±0.050 mL (50 mL burette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Type\u003c\/td\u003e\n\u003ctd\u003eOverhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Range\u003c\/td\u003e\n\u003ctd\u003e200 to 2500 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Resolution\u003c\/td\u003e\n\u003ctd\u003e100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Calibration\u003c\/td\u003e\n\u003ctd\u003esingle point, offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to 5 points with standard or custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003e1×10\u003csup\u003e–6\u003c\/sup\u003e to 9.999×10\u003csup\u003e10\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration\u003c\/td\u003e\n\u003ctd\u003eup to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105 °C\u003cbr\u003e23.0 to 221.0 °F\u003cbr\u003e268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C \/ ±0.2 °F \/ ±0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage Methods\u003c\/td\u003e\n\u003ctd\u003eUp to 100 titration methods (standard and user-defined)\u003cbr\u003eUp to 30 autosampler sequences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage Reports\u003c\/td\u003e\n\u003ctd\u003eUp to 100 titration and pH \/ mV \/ ISE reports\u003cbr\u003eUp to 40 autosampler tray reports (e.g. 720 reports for 18 beaker tray)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections Measurement\u003c\/td\u003e\n\u003ctd\u003e2 × BNC socket (pH, ORP, ISE half-cell, and ISE combination electrodes)\u003cbr\u003e2 × 4 mm banana socket (reference electrode)\u003cbr\u003e2 × RCA socket (temperature sensor)\u003cbr\u003e2 × 6-pin connector (stirrer)\u003cbr\u003e2 × 3.5 mm Jack connector (digital sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections Peripheral\u003c\/td\u003e\n\u003ctd\u003e1 × DB-9 socket (serial interface)\u003cbr\u003e2 × USB type C (external PC keyboard, PC connection)\u003cbr\u003e1 × 5-pin connector (balance)\u003cbr\u003e1 × USB standard A (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Holder\u003c\/td\u003e\n\u003ctd\u003e4 × multi-purpose slots (titrant \/ reagent tubes)\u003cbr\u003e3 × 12-mm electrode slots\u003cbr\u003e1 × temperature sensor slot\u003cbr\u003e1 × overhead stirrer slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7 in. graphical color display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 - 240 VAC, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Draw\u003c\/td\u003e\n\u003ctd\u003e0.5 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eABS, PC-ABS, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e315 × 205 × 375 mm (12.4 × 8.1 × 14.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 4.3 kg (9.5 lbs.) with 1 pump, stirrer, and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e10 to 40 °C (50 to 104 °F); up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e–20 to 70 °C (–4 to 158 °F); up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/MAN932_SW-2.2.2_06_26.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Automatic Potentiometric Titrator Manual (HI932)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871462064497,"sku":"HI932","price":1803515.63,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI932-Right-Front-Raised-2-4__30029.1746719177.webp?v=1792646987"}],"url":"https:\/\/hannainst.in\/collections\/parameter-alkalinity.oembed?page=2","provider":"hanna","version":"1.0","type":"link"}