{"title":"ISE","description":"","products":[{"product_id":"sodium-combination-ion-selective-electrode-ise-fc300b","title":"Sodium Combination Ion Selective Electrode (ISE) - FC300B","description":"\u003cp\u003eThe sodium sensitive membrane should be conditioned before performing a calibration. The conditioning of the electrode is a two-step process in which the glass is etched then rehydrated. The first step is etching. This process removes a thin layer of sensitive glass from the sodium membrane, exposing a sodium-containing fresh surface. The second step is rehydration in which the probe is placed in storage solution to rehydrate the glass membrane. Allowing the glass to rehydrate after etching provides optimum conditions for the exchange of sodium ions between the membrane and solution.\u003c\/p\u003e\n\u003cp\u003eFor the FC300B to measure sodium accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the sodium ionic strength adjuster (ISA) solution. The sodium ISA is important for two reasons. One is that the ISA buffers the pH of the standard and sample to above pH 9.8. This removes any interference from hydrogen ions that occur at lower pH's. The second purpose of the ISA is to ensure that the activity coefficient is constant so the concentration of free sodium ions can be measured. Having solutions with a constant ionic strength reduces the margin of error between measurements of different samples at different concentrations.\u003c\/p\u003e\n\u003cp\u003eThe FC300B sodium glass ISE can measure from 10µM (0.23 mg\/L) to 1M (22, 990 mg\/L).\u003c\/p\u003e\n\u003ch2\u003eConversion Table for Na\u003csup\u003e+\u003c\/sup\u003e and NaCl\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable rules=\"all\"\u003e\n\u003ccolgroup\u003e \u003ccol width=\"437\"\u003e \u003ccol width=\"171\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) Na\u003csup\u003e+\u003c\/sup\u003e to ppm (mg\/L) Na\u003csup\u003e+\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e22990\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) Na\u003csup\u003e+\u003c\/sup\u003e to M (moles\/L) Na\u003csup\u003e+\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e4.35 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) Na\u003csup\u003e+\u003c\/sup\u003e to ppm (mg\/L) NaCl\u003c\/td\u003e\n\u003ctd\u003e2.54197\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) NaCl to ppm (mg\/L) Na\u003csup\u003e+\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003ctd\u003e0.39339\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSpherical Glass Tip\u003c\/strong\u003e - The spherical shaped tip design allows for a wide area of contact with the sample, permitting a faster electrode response with a higher degree of stability.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGlass Electrode Body\u003c\/strong\u003e - The glass electrode body is suitable for a wide range of applications due to its chemical resistance. The glass electrode is compatible with many non-aqueous solvents and other aggressive chemicals. Glass is also resistant to many forms of radiation, such as ultraviolet radiation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e -The FC300B has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA glass ion selective electrode develops a voltage due to the ion exchange that occurs between the solution and the sensing membrane. The selective glass membrane blown on the tip of the sensor exchanges ions with the solution being measured. The charge imbalance between the membrane surface and internal cell of the sensor produces a voltage that changes in response to the sample's ion activity. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eFC300B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSodium Combination Ion Selective Electrode (ISE) - FC300B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eSodium (Na\u003csup\u003e+\u003c\/sup\u003e) 1.0M to 1 x 10-5M, 22,990 to 0.23 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eglass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 9.75 to 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003eOverall: 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope: +57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/FC300B\" target=\"_blank\" rel=\"noopener\"\u003eSodium Combination Ion Selective Electrode (ISE) - FC300B\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871187829105,"sku":"FC300B","price":45785.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fc300_1200.jpg?v=1792645845"},{"product_id":"professional-waterproof-portable-ph-orp-ise-meter-hi98191","title":"Professional Waterproof Portable pH\/ORP\/ISE Meter - HI98191","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eFor the measurement of pH the HI98191 comes with a HI72911B titanium body pH electrode with a built-in temperature sensor for automatic temperature compensated readings. The titanium body is chemically resistant to aggressive chemicals and is virtually unbreakable.\u003c\/p\u003e\n\u003cp\u003eHanna's unique CAL Check™ feature alerts the user to potential problems during the pH calibration process. By comparing previous calibration data to the current calibration the meter will alert the user with display prompts when the probe needs to be cleaned or is broken and if the pH buffer might be contaminated. After calibration the overall probe condition is displayed as a percentage from 0 to 100% in increments of 10%. The probe condition is affected by both the offset and slope characteristics of the pH electrode and is displayed on the measurement screen on the day of calibration and in the GLP data. pH calibration can be performed up to five points with seven preprogrammed standard pH buffers and five custom ones to achieve a pH accuracy of ±0.002 with ±0.001 pH resolution.\u003c\/p\u003e\n\u003cp\u003eThe HI98191 has 15 different ISE sensors preprogrammed within the meter. By selecting the appropriate ISE in the ISE Setup Menu, the appropriate ion charge and ion molar weight are applied to display ISE slope percentage. Users can then calibrate up to five points with the choice of six standard values. This meter allows an extensive choice of measurement units (ppm, ppt, g\/L, ppb, μg\/L, mg\/mL, M, mol\/L, mmol\/L, % w\/v, user defined) and has an expanded measuring range of 1.00 x 10\u003csup\u003e-7\u003c\/sup\u003e to 9.99 x 10\u003csup\u003e10\u003c\/sup\u003e.\u003c\/p\u003e\n\u003cp\u003ePressing the \"AutoHold\" virtual key seen in measurement mode, the meter will freeze a stable reading allowing for the reading to be documented or logged. An \"out of calibration range\" warning can be enabled that will alert the user when a reading is not within the bracket of calibrated pH values.\u003c\/p\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 300 samples (100 each for pH, mV, and ISE). This data along with the associated GLP data can then be transferred to a PC with Hanna's HI920015 micro USB cable and HI92000 software.\u003c\/p\u003e\n\u003cp\u003eAccess help at any time at a press of a dedicated button and view content specific information based on the screen that is currently being viewed.\u003c\/p\u003e\n\u003cp\u003eThe high contrast graphic LCD is easy to read outdoors in bright sunlight as well in low-lit areas with the backlight. A combination of dedicated and virtual keys allows easy, intuitive operation in a choice of languages.\u003c\/p\u003e\n\u003cp\u003eThe compact, durable carrying case is thermoformed to hold all necessary components for taking a field measurement, including the meter, electrode and beakers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-setup.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eSetup Screen\u003c\/strong\u003e\nOur extensive setup screen features a host of configurable options such as time, date, temperature units and language for help screens and guides.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\npH calibration features detailed CAL Check™ messages. Alerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-HI98190-GLP.jpg\" alt=\"GLP\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGLP\u003c\/strong\u003e\nComprehensive GLP functions are directly accessible by pressing the GLP key. Calibration data, including: date, time, offset, slope and buffers used in the last calibration can be reviewed.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98191-ISE-Fluoride.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eISE Measurements\u003c\/strong\u003e\nThe HI98191 includes ISE measurements when used with our wide selection of ISE electrodes or a custom version.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eErgonomic, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003epH CAL Check™\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAlerts user to potential problems during calibration including when to clean electrode and possible buffer contamination.\u003c\/li\u003e\n\u003cli\u003eDisplays overall probe condition based on offset and slope after calibration\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eISE direct concentration readout in a choice of concentration units\u003c\/h5\u003e\n\u003ch5\u003eAutomatic Temperature Compensation\u003c\/h5\u003e\n\u003ch5\u003eFive-point pH calibration with seven standard buffers and five custom buffers\u003c\/h5\u003e\n\u003ch5\u003eLog-on-demand\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eStore measurement data at the press of a button\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAutoHold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes a stable reading on the display for recording or logging\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data including date, time, calibrated values, slope and offset (pH)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003e200-hour battery life with battery level displayed on measurement screen\u003c\/h5\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Food \u0026amp; Beverage, Plating, Water and Wastewater, Chemical Manufacturing, Agriculture, and Environmental\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/1pmzf9o20h?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/2872b8cf233378bfb91dce12e7b14732390aacd8.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eProfessional Waterproof Portable pH\/ORP\/ISE Meter - HI98191\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1; ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) + five custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e10¹² Ohms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003efrom 1.00 E⁻⁷ to 9.99 E¹⁰ concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e3 digits 0.01; 0.1; 1; 10 concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% of reading (monovalent ions), ±1% of reading (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration\u003c\/td\u003e\n\u003ctd\u003eup to five point calibration, six standard solutions available (0.1, 1, 10, 100, 1000, 10000 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C (±0.8°F) (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic from -20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI72911B Titanium body, pH electrode with internal temperature sensor, BNC connector and 1 m (3.3’ cable)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e300 samples (100 each range pH, mV and ISE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 200 hours of continuous use without backlight (50 hours with backlight)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98191 is supplied with HI72911B titanium body pH electrode, HI7004M pH 4.01 buffer solution (230 mL), HI7007M pH 7.01 buffer solution (230 mL), HI700601 electrode cleaning solution sachet (2 x 20 mL), 100 mL plastic beaker (2), 1.5V AA batteries (4), HI92000 PC software, HI920015 micro USB cable, instruction manual, quick start guide, instrument quality certificate, and HI720191 hard carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98191\" target=\"_blank\" rel=\"noopener\"\u003eProfessional Waterproof Portable pH\/ORP\/ISE Meter - HI98191\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871192252785,"sku":"HI98191","price":94938.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98191_manual.jpg?v=1792645854"},{"product_id":"stainless-steel-temperature-probe-hi7662-t","title":"Stainless Steel Temperature Probe - HI7662-T","description":"\u003cp\u003eHI7662-T is a stainless steel temperature probe that can be used for Hanna's benchtop meters and potentiometric titration systems.\u003c\/p\u003e\n\u003cp\u003eHigh accuracy thermometers provide the versatility,  speed,  and reliability required by users in all areas concerning temperature measurement. Speed is important when the reactions being monitored have the potential to change rapidly,  which can happen during titrations,  or standard or sample additions.\u003c\/p\u003e\n\u003cp\u003epH readings must be temperature compensated in order to obtain accurate results. The source of temperature measurement can be from the HI7662-T Temperature Sensor or from a trimmer that is manually adjusted. In either case,  the instrument is adjusting the pH reading to compensate for changes in the pH sensor. Temperature compensation provides the actual pH of the buffer or sample at the temperature of measurement.\u003c\/p\u003e\n\u003cp\u003eTemperature compensation can be obtained in three ways:\u003c\/p\u003e\n\u003col\u003e\n\u003cli\u003eA separate probe specifically for measuring temperature\u003c\/li\u003e\n\u003cli\u003eA probe with a temperature sensor built-in\u003c\/li\u003e\n\u003cli\u003eManual adjustment for temperature\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7662-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7662-T Stainless Steel Temperature Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e - 5.0 to 105.0°C, 23.0 to 221.0°F, 268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 °C, 0.1 °F, 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.1°C, ±0.4°F, ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor Type\u003c\/td\u003e\n\u003ctd\u003e NTC thermistor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e AISI 316 stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 1 m (3.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e For use with Hanna benchtop meters and potentiometric titration systems with a phono connector input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7662-T\"\u003eHI7662-T Stainless Steel Temperature Probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871193792881,"sku":"HI7662-T","price":9600.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7662-tw_temperature-probe-2100x2100-f2e73f65-ddfd-45f4-b7ac-f9f3c97a8796.jpg?v=1792645857"},{"product_id":"ionic-strength-adjuster-isa-for-halide-ises-hi4000-00","title":"Ionic Strength Adjuster (ISA) for Halide ISEs - HI4000-00","description":"\u003cp\u003eHI4000-00 is an ionic strength adjuster (ISA) solution for use with bromide,  cadmium,  chloride,  cupric,  iodide,  and silver\/sulfide ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Halide ISEs - HI4000-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-00\"\u003eIonic Strength Adjuster (ISA) for Halide ISEs - HI4000-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276466545,"sku":"HI4000-00","price":9924.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-00.jpg?v=1792646027"},{"product_id":"ise-slope-check-buffers-with-chloride-background-hi4000-47","title":"ISE Slope Check Buffers with Chloride Background - HI4000-47","description":"\u003cp\u003eHI4000-47 is a package containing pH 4 and pH 7 buffer packets with chloride ions and two plastic beakers. The special pH 4 and pH 7 buffers have a chloride background to verify the inner pH glass assembly housed within the ammonia and carbon dioxide gas sensing ISEs.\u003c\/p\u003e\n\u003cp\u003eBefore assembling an ammonia or carbon dioxide ISE for the first time,  or if reactivating after storage,  the inner glass assembly should be conditioned and tested as a pH electrode. The pH buffer packets can be added to 50 mL of deionized or distilled water and the sensor assembly carefully immersed in solution. When the mV measurement in each buffer solution is stable and recorded,  the mV difference can be calculated. A calculated mV difference equal or greater than 160 mV is acceptable for temperatures between 20 and 25℃.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e ISE Slope Check Buffers with Chloride Background - HI4000-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e packets and beakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 10 packets each buffer; 2 beakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-47\"\u003eISE Slope Check Buffers with Chloride Background - HI4000-47\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276499313,"sku":"HI4000-47","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-47.jpg?v=1792646027"},{"product_id":"liquid-membrane-ise-sensor-handle-hi4000-50","title":"Liquid Membrane ISE Sensor Handle - HI4000-50","description":"\u003cp\u003eThe HI4000-50 replacement sensor handle is compatible with Hanna's liquid ISE modules. The sensor handle can be used as a sensing half-cell with the calcium,  nitrate,  or potassium half-cell modules. The HI5315 reference half-cell electrode is required for use with the HI4000-50 sensing half-cell to complete the electrical circuit and to provide a stable reference voltage.\u003c\/p\u003e\n\u003ch4\u003eFeatures at-a-glance\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eReplaceable Liquid Modules\u003c\/strong\u003e - The calcium,  nitrate,  and potassium half-cell modules can easily be replaced on the sensor handle. The HI4000-50 acts as the sensing electrode in an ISE measurement system.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body is composed of durable epoxy material.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4000-50 has a universal BNC connector for easy connection to any meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch4\u003eTheory of Operation\u003c\/h4\u003e\n\u003cp\u003eA liquid membrane ion selective electrode develops a voltage due to the ion exchange that occurs between the solution and the polymer membrane that contains organic ion exchange resin. When the ionic strength of the solution is fixed by the addition of ISA,  the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Liquid Membrane ISE Sensor Handle - HI4000-50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e epoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-50\"\u003eLiquid Membrane ISE Sensor Handle - HI4000-50\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276564849,"sku":"HI4000-50","price":38702.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-50_2.jpg?v=1792646029"},{"product_id":"replacement-ph-assembly-for-ammonia-ise-hi4000-51","title":"Replacement pH Assembly for Ammonia ISE - HI4000-51","description":"\u003cp\u003eThe HI4000-51 replacement pH reference assembly is for use with Hanna's HI4101 ammonia gas sensing ion selective electrode (ISE). This internal glass pH assembly provides the sensing and reference components for the ammonia combination ISE.\u003c\/p\u003e\n\u003ch4\u003eTheory of Operation\u003c\/h4\u003e\n\u003cp\u003eA gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film of electrolyte are the same. The pH change is proportional to the concentration of dissolved gas in the sample solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4000-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eReplacement pH Assembly for Ammonia ISE - HI4000-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4000-51\" target=\"_blank\" rel=\"noopener\"\u003eReplacement pH Assembly for Ammonia ISE - HI4000-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276597617,"sku":"HI4000-51","price":49080.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-51.jpg?v=1792646029"},{"product_id":"bromide-combination-ion-selective-electrode-ise-hi4102","title":"Bromide Combination Ion-Selective Electrode (ISE) - HI4102","description":"\u003cp\u003eHanna's solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4102 to measure bromide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free bromide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4102 bromide solid state ISE can measure from 1µM (0.08 mg\/L) to 1M (79, 910 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for Br\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"200\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e7.99 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e1.252 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4102 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eBromide Combination Ion-Selective Electrode (ISE) - HI4102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003ebromide (Br\u003csup\u003e-\u003c\/sup\u003e) 1.0M to 1 10\u003csup\u003e-6\u003c\/sup\u003eM, 79,910 to 0.08 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 2 to 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4102\" target=\"_blank\" rel=\"noopener\"\u003eBromide Combination Ion-Selective Electrode (ISE) - HI4102\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276630385,"sku":"HI4102","price":121196.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4102_2016.jpg?v=1792646029"},{"product_id":"chloride-combination-ion-selective-electrode-ise-hi4107","title":"Chloride Combination Ion-Selective Electrode (ISE) - HI4107","description":"\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4107 to measure chloride accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free chloride ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4107 chloride solid state ISE can measure from 50µM (1.8 mg\/L) to 1M (35, 500 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for Cl\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"210\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e3.500 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e2.857 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4107 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChloride Combination Ion-Selective Electrode (ISE) - HI4107\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003echloride (Cl\u003csup\u003e-\u003c\/sup\u003e) 1.0M to 5 x 10\u003csup\u003e-5\u003c\/sup\u003eM, 35,500 to 1.8 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 2 to 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4107\" target=\"_blank\" rel=\"noopener\"\u003eChloride Combination Ion-Selective Electrode (ISE) - HI4107\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278006641,"sku":"HI4107","price":121196.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4107_2016.jpg?v=1792646031"},{"product_id":"cadmium-combination-ion-selective-electrode-ise-hi4103","title":"Cadmium Combination Ion-Selective Electrode (ISE) - HI4103","description":"\u003cp\u003eHanna's solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4103 to measure cadmium accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the HI4000-00 ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free cadmium ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4103 cadmium solid state ISE can measure from 0.1µM (0.01 mg\/L) to 0.1M (11, 200 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for Cd\u003csup\u003e2+\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"*\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e1.124 x 10\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e8.896 x 10\u003csup\u003e-6\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4103 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCadmium Combination Ion-Selective Electrode (ISE) - HI4103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003ecadmium (Cd\u003csup\u003e2+\u003c\/sup\u003e) 0.1M to 1 10\u003csup\u003e-7\u003c\/sup\u003eM, 11,200 to 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 2 to 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope +28 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4103\" target=\"_blank\" rel=\"noopener\"\u003eCadmium Combination Ion-Selective Electrode (ISE) - HI4103\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278039409,"sku":"HI4103","price":141399.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4103_2016.jpg?v=1792646031"},{"product_id":"copper-combination-ion-selective-electrode-ise-hi4108","title":"Copper Combination Ion-Selective Electrode (ISE) - HI4108","description":"\u003cp\u003eHanna’s solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4108 to measure cupric ions accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the HI4000-00 ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free cupric ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4108 cupric solid state ISE can measure from 1µM (0.065 mg\/L) to 0.1M (6, 355 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for Cu\u003csup\u003e2+\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"210\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e6.354 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e1.574 x 10\u003csup\u003e-4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4108 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCopper Combination Ion-Selective Electrode (ISE) - HI4108\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003ecupric (Cu\u003csup\u003e2+\u003c\/sup\u003e) 0.1M to 1 10\u003csup\u003e-6\u003c\/sup\u003eM, 6,355 to 0.065 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 3 to 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope +27 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4108\" target=\"_blank\" rel=\"noopener\"\u003eCopper Combination Ion-Selective Electrode (ISE) - HI4108\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278072177,"sku":"HI4108","price":150950.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4108_1200.jpg?v=1792646031"},{"product_id":"iodide-combination-ion-selective-electrode-ise-hi4111","title":"Iodide Combination Ion-Selective Electrode (ISE) - HI4111","description":"\u003cp\u003eThe HI4111 iodide selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver iodide sensing membrane.\u003c\/p\u003e\n\u003cp\u003eHanna's solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone,  producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4111 to measure iodide accurately,  it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free iodide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4111 iodide solid state ISE can measure from 0.1µM (0.01 mg\/L) to1M (127, 000 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for I\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"210\"\u003e\n\u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eMultiply\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003emoles\/L (M) to ppm (mg\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e1.269 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eppm (mg\/L) to M (moles\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e7.88 x 10\u003csup\u003e-6\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble,  compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4111 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA,  the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Iodide Combination Ion-Selective Electrode (ISE) - HI4111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e combination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e iodide (I\u003csup\u003e-\u003c\/sup\u003e) 1M to 1 10\u003csup\u003e-7\u003c\/sup\u003eM, 127,000 to 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Approximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4111\"\u003eIodide Combination Ion-Selective Electrode (ISE) - HI4111\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278104945,"sku":"HI4111","price":97047.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4111_2016.jpg?v=1792646033"},{"product_id":"lead-sulfate-combination-ion-selective-electrode-ise-hi4112","title":"Lead\/Sulfate Combination Ion-Selective Electrode (ISE) - HI4112","description":"\u003cp\u003eHanna’s solid-state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4112 to measure lead accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the lead ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free lead ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4112 lead\/sulfate solid state ISE can measure from 1µM (0.21 mg\/L) to 0.1M (20, 700 mg\/L).\u003c\/p\u003e\n\u003cp\u003eThe HI4112 can also be used as an indicator to follow the progress and detect the endpoint of a precipitation titration of sulfate. During the titration, the lead\/sulfate ISE follows the lead concentration while a lead perchlorate solution is used to titrate the sample. The lead in the titrant solution reacts with the sulfate ions present in the sample to form a precipitate. Once all of the lead and sulfate ions have reacted, a change in mV occurs to signal the endpoint, and ultimately the sulfate concentration.\u003c\/p\u003e\n\u003ch4\u003eConversion Table for Pb\u003csup\u003e2+\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"210\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e2.072 x 10\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e4.826 x 10\u003csup\u003e-6\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4112 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eLead\/Sulfate Combination Ion-Selective Electrode (ISE) - HI4112\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003elead (Pb\u003csup\u003e2+\u003c\/sup\u003e) 0.1M to 1 10\u003csup\u003e-6\u003c\/sup\u003eM, 20,700 to 0.21 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 4 to 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope +27 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4112\" target=\"_blank\" rel=\"noopener\"\u003eLead\/Sulfate Combination Ion-Selective Electrode (ISE) - HI4112\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278137713,"sku":"HI4112","price":150950.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4112_2016.jpg?v=1792646033"},{"product_id":"silver-sulfide-combination-ion-selective-electrode-ise-hi4115","title":"Silver\/Sulfide Combination Ion-Selective Electrode (ISE) - HI4115","description":"\u003cp\u003eHanna's solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eMeasuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4115 silver\/sulfide solid state ISE can measure silver from 1µM (0.11 mg\/L) to 1M (107, 900 mg\/L) and sulfide from 0.1µM (0.003 mg\/L) to 1M (32, 100 mg\/L).\u003c\/p\u003e\n\u003ch5\u003eSilver(Ag\u003cstrong\u003e\u003csup\u003e+\u003c\/sup\u003e\u003c\/strong\u003e\u003cstrong\u003e)\u003c\/strong\u003e\n\u003c\/h5\u003e\n\u003cp\u003eFor the HI4015 to measure silver accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free silver ions can be measured.\u003c\/p\u003e\n\u003cp\u003eConversion Table for Ag\u003csup\u003e+\u003c\/sup\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"210\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e1.0787 x 10\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e9.27 x 10\u003csup\u003e-6\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch5\u003eSulfide(S\u003csup\u003e2-\u003c\/sup\u003e)\u003c\/h5\u003e\n\u003cp\u003eFor accurate sulfide measurement, it is important that sulfur is released from hydrogen and that sulfide oxidation is prevented with the sulfide antioxidant buffer solution (SAOB). The SAOB ensures that the solution pH is above pH 12, reducing the effect of interfering ions and releasing sulfur from hydrogen ions. SAOB also acts to stabilize the activity coefficient so the concentration of free sulfide ions can be measured.\u003c\/p\u003e\n\u003ch4\u003eConversion Table for S\u003csup\u003e2-\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"210\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e3.207 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e3.12 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4115 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eSilver\/Sulfide Combination Ion-Selective Electrode (ISE) - HI4115\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003esilver (Ag\u003csup\u003e+\u003c\/sup\u003e) 1M to 1 10\u003csup\u003e-6\u003c\/sup\u003eM, 107,900 to 0.11 mg\/L (ppm)\nsulfide (S\u003csup\u003e2-\u003c\/sup\u003e) 1M to 1 10\u003csup\u003e-7\u003c\/sup\u003eM, 32,100 to 0.003 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003ePEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 2 to 8 (silver); pH 12 to 14 (sulfide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e+56 mV (silver); -28 mV (sulfide)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4115\" target=\"_blank\" rel=\"noopener\"\u003eSilver\/Sulfide Combination Ion-Selective Electrode (ISE) - HI4115\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278170481,"sku":"HI4115","price":128992.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4115_2016.jpg?v=1792646034"},{"product_id":"ammonia-combination-ion-selective-electrode-ise-hi4101","title":"Ammonia Combination Ion-Selective Electrode (ISE) - HI4101","description":"\u003cp\u003eAmmonia can exist in two different forms: ammonia as a gas (NH\u003csub\u003e3\u003c\/sub\u003e) and ammonium as the ionized form (NH\u003csup\u003e4+\u003c\/sup\u003e). The concentration of each form in a solution is dependent on the solution's pH. The pKa is the pH value at which ammonia and ammonium are in equilibrium. The pKa of the ammonia\/ammonium relationship is 9.24; thus, at a pH of 9.24 there will be an equal concentration of ammonia and ammonium. As pH decreases, becoming more acidic, the concentration of ammonium increases and ammonia decreases. The opposite occurs as the pH increases. The actual concentration for either species can be determined by knowing the concentration of ammonia and the pH of the sample.\u003c\/p\u003e\n\u003cp\u003eFor the HI4101 to measure ammonia accurately, it is important that the pH of the calibration standards and sample be raised with the ammonia ionic strength adjuster (ISA) solution. The ammonia ISA raises the pH of the solution to pH 11. Any ammonium present in the calibration standards and sample will be converted to ammonia, ensuring an accurate measurement. The HI4101 ammonia gas sensing ISE can measure from 1µM (0.02 mg\/L) to 1M (17, 000 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for NH\u003csub\u003e3\u003c\/sub\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"200\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e1.70 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e5.882 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eConversion Table for NH\u003csub\u003e3\u003c\/sub\u003e-N\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"*\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolarity (moles\/L) NH\u003csub\u003e3\u003c\/sub\u003e to mg\/L (ppm) NH\u003csub\u003e3\u003c\/sub\u003e-N\u003c\/td\u003e\n\u003ctd\u003e1.40 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eReplaceable PTFE Membranes\u003c\/strong\u003e - Gas sensing ISEs are combination electrodes that detect dissolved gases in a solution. The sensing element is separated from the sample solution by a gas permeable, PTFE membrane that is easy to replace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Delrin® Body\u003c\/strong\u003e - The probe body is composed of durable Delrin plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4101 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film of electrolyte are the same. The pH change is proportional to the concentration of dissolved gas in the sample solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAmmonia Combination Ion-Selective Electrode (ISE) - HI4101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eammonia (NH₃) 1.0M to 1 x 10-6 M, 17000 to 0.02 mg\/L (ppm); ammonia-nitrogen (NH₃-N) 14000 to 0.016 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eDelrin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; pH 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4101\" target=\"_blank\" rel=\"noopener\"\u003eAmmonia Combination Ion-Selective Electrode (ISE) - HI4101\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278367089,"sku":"HI4101","price":104361.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4101_y2016.jpg?v=1792646035"},{"product_id":"ammonia-ise-filling-solution-hi4001-40","title":"Ammonia ISE Filling Solution - HI4001-40","description":"\u003cp\u003eThe HI4001-40 fill solution is a chloride ion-containing electrolyte that is required to provide a reference potential for the HI4101 ammonia gas sensing ion selective electrode (ISE). As ammonia diffuses through the gas permeable membrane,  the thin film of electrolyte on the surface of the pH sensing glass undergoes a pH change. The change in pH of the filling solution is proportional to the concentration of ammonia gas in the solution. The HI4001-40 is four bottles of 30 mL ammonia filling solution that ensure optimum measurement performance from the HI4101 ammonia ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE Filling Solution - HI4001-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-40\"\u003eAmmonia ISE Filling Solution - HI4001-40\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278399857,"sku":"HI4001-40","price":15692.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-40_2.jpg?v=1792646035"},{"product_id":"ammonia-ise-100-ppm-standard-hi4001-02","title":"Ammonia ISE 100 ppm Standard - HI4001-02","description":"\u003cp\u003eHI4001-02 is a 100 mg\/L (ppm) standard solution of ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N) used to calibrate the ammonia gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE 100 ppm Standard - HI4001-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 mg\/L (ppm) ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-02\"\u003eAmmonia ISE 100 ppm Standard - HI4001-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278432625,"sku":"HI4001-02","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-02-1200by1200-rgb.jpg?v=1792646036"},{"product_id":"ammonia-ise-1000-ppm-standard-hi4001-03","title":"Ammonia ISE 1000 ppm Standard - HI4001-03","description":"\u003cp\u003eHI4001-03 is a 1000 mg\/L (ppm) standard solution of ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N) used to calibrate the ammonia gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE 1000 ppm Standard - HI4001-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1000 mg\/L (ppm) ammonia (as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-03\"\u003eAmmonia ISE 1000 ppm Standard - HI4001-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278498161,"sku":"HI4001-03","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-03.jpg?v=1792646037"},{"product_id":"ionic-strength-adjuster-isa-for-ammonia-and-cyanide-ises-hi4001-00","title":"Ionic Strength Adjuster (ISA) for Ammonia and Cyanide ISEs - HI4001-00","description":"\u003cp\u003eHI4001-00 is an alkaline ionic strength adjuster (ISA) solution for use with ammonia and cyanide ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Ammonia and Cyanide ISEs - HI4001-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-00\"\u003eIonic Strength Adjuster (ISA) for Ammonia and Cyanide ISEs - HI4001-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278530929,"sku":"HI4001-00","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-00.jpg?v=1792646037"},{"product_id":"ammonia-ise-conditioning-and-storage-solution-hi4001-45","title":"Ammonia ISE Conditioning and Storage Solution - HI4001-45","description":"\u003cp\u003eThe HI4001-45 solution is for the conditioning and storage for the HI4101 ammonia gas sensing ion selective electrode (ISE). Measurement of ammonia in solutions is determined by a pH change of the internal thin film of electrolyte. This conditioning and storage solution is necessary to keep the glass pH sensing element hydrated in order to accurately determine ammonia concentrations. The HI4001-45 is a 500 mL bottle of conditioning and storage solution that ensures optimum measurement performance from the HI4101 ammonia ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE Conditioning and Storage Solution - HI4001-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-45\"\u003eAmmonia ISE Conditioning and Storage Solution - HI4001-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278596465,"sku":"HI4001-45","price":8101.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-45.jpg?v=1792646038"},{"product_id":"ammonia-ise-0-1m-standard-hi4001-01","title":"Ammonia ISE 0.1M Standard - HI4001-01","description":"\u003cp\u003eHI4001-01 is a 0.1M standard solution of ammonia used to calibrate the ammonia gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE 0.1M Standard - HI4001-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M ammonia\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-01\"\u003eAmmonia ISE 0.1M Standard - HI4001-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278629233,"sku":"HI4001-01","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-01-1200by1200-rgb.jpg?v=1792646039"},{"product_id":"replacement-membrane-cap-for-ammonia-ise-hi4000-52","title":"Replacement Membrane Cap for Ammonia ISE - HI4000-52","description":"\u003cp\u003eThe HI4000-52 replacement membrane cap is for use with Hanna's HI4101 ammonia gas sensing ion selective electrode (ISE). This durable Delrin® cap easily screws onto the outer body of the ISE when the gas-sensing membrane needs replacement.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Replacement Membrane Cap for Ammonia ISE - HI4000-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 1 cap\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-52\"\u003eReplacement Membrane Cap for Ammonia ISE - HI4000-52\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278662001,"sku":"HI4000-52","price":5021.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-52.jpg?v=1792646039"},{"product_id":"replacement-ph-assembly-for-carbon-dioxide-ise-hi4000-54","title":"Replacement pH Assembly for Carbon Dioxide ISE - HI4000-54","description":"\u003cp\u003eThe HI4000-54 replacement pH reference assembly is for use with Hanna's HI4105 carbon dioxide gas sensing ion selective electrode (ISE). This internal glass pH assembly provides the sensing and reference components for the carbon dioxide combination ISE.\u003c\/p\u003e\n\u003ch4\u003eTheory of Operation\u003c\/h4\u003e\n\u003cp\u003eA gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film of electrolyte are the same. The pH change is proportional to the concentration of dissolved gas in the sample solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Replacement pH Assembly for Carbon Dioxide ISE - HI4000-54\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-54\"\u003eReplacement pH Assembly for Carbon Dioxide ISE - HI4000-54\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278694769,"sku":"HI4000-54","price":49080.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-54.jpg?v=1792646040"},{"product_id":"halide-polishing-strips-24-pcs-hi4000-70","title":"Halide Polishing Strips (24 pcs) - HI4000-70","description":"\u003cp\u003eThe HI4000-70 is a pack of 24 halide polishing strips. A scratched,  pitted,  or oxidized sensing surface can be restored with HI4000-70 polishing strip. The user simply needs a small portion of the micro abrasive strip to polish a solid state membrane. By wetting the frosted side with purified water,  the polishing strip gently reconditions the sensing surface. A worn pellet surface can cause drift,  decreased sensitivity at low concentration levels,  or poor repeatability between measurements. Optimum ISE response can be restored by removing the damaged surface with the HI4000-70 polishing strips.\u003c\/p\u003e\n\u003cp\u003eHI4000-70 is made for use on the following ion selective electrodes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI4002 \/ HI4102 Bromide ISE\u003c\/li\u003e\n\u003cli\u003eHI4003 \/ HI4103 Cadmium ISE\u003c\/li\u003e\n\u003cli\u003eHI4007 \/ HI4107 Chloride ISE\u003c\/li\u003e\n\u003cli\u003eHI4008 \/ HI4108 Cupric ISE\u003c\/li\u003e\n\u003cli\u003eHI4009 \/ HI4109 Cyanide ISE\u003c\/li\u003e\n\u003cli\u003eHI4011 \/ HI4111 Iodide ISE\u003c\/li\u003e\n\u003cli\u003eHI4012 \/ HI4112 Lead\/Sulfate ISE\u003c\/li\u003e\n\u003cli\u003eHI4015 \/ HI4115 Silver\/Sulfide ISE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Halide Polishing Strips (24 pcs) - HI4000-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 24 strips\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-70\"\u003eHalide Polishing Strips (24 pcs) - HI4000-70\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280857457,"sku":"HI4000-70","price":4450.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-70.jpg?v=1792646041"},{"product_id":"ammonia-ise-membrane-kit-20-pcs-hi4001-51","title":"Ammonia ISE Membrane Kit (20 pcs) - HI4001-51","description":"\u003cp\u003eThe HI4001-51 replacement membrane kit contains 20 loose PTFE membranes for the ammonia gas sensing ISE. When the ammonia ISE is first being assembled,  or after a membrane is worn,  the HI4001-51 membrane kit allows for easy assemblage or replacement. With the help of HI740159 plastic tweezers and a pair of laboratory gloves,  the PTFE membrane is ensured to remain dry and undamaged for more reliable,  accurate measurements. The loose PTFE membrane is placed on the outer probe body and pulled taut once the membrane cap is screwed on.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4001-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia ISE Membrane Kit (20 pcs) - HI4001-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 20 membranes\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4001-51\"\u003eAmmonia ISE Membrane Kit (20 pcs) - HI4001-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280890225,"sku":"HI4001-51","price":14605.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-51.jpg?v=1792646041"},{"product_id":"bromide-half-cell-ion-selective-electrode-ise-hi4002","title":"Bromide Half-Cell Ion-Selective Electrode (ISE) - HI4002","description":"\u003cp\u003eThe HI4002 bromide ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed silver bromide sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.\u003c\/p\u003e\n\u003cp\u003eHanna's solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone,  producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4002 to measure bromide accurately,  it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free bromide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4002 bromide solid state ISE can measure from 1µM (0.08 mg\/L) to 1M (79, 910 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for Br\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"220\"\u003e\n\u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eMultiply\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003emoles\/L (M) to ppm (mg\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e7.99 x 10\u003csup\u003e4\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eppm (mg\/L) to M (moles\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e1.252 x 10\u003csup\u003e-5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Solid state half-cell ISEs are electrodes that detect free ions in a solution. The highly insoluble,  compressed sensing pellet is attached to the HI4002 bromide half-cell by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body of the bromide half-cell ISE is composed of durable epoxy resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4002 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA,  the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Bromide Half-Cell Ion-Selective Electrode (ISE) - HI4002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e solid state; half-cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e Bromide (Br\u003csup\u003e-\u003c\/sup\u003e) 1.0M to 1 10\u003csup\u003e-6\u003c\/sup\u003eM, 79,910 to 0.08 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e epoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e pH 2 to 12.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Approximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4002\"\u003eBromide Half-Cell Ion-Selective Electrode (ISE) - HI4002\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280922993,"sku":"HI4002","price":77399.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4002_2016.jpg?v=1792646042"},{"product_id":"bromide-ise-0-1m-standard-hi4002-01","title":"Bromide ISE 0.1M Standard - HI4002-01","description":"\u003cp\u003eHI4002-01 is a 0.1M standard bromide solution used to calibrate the bromide solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Bromide ISE 0.1M Standard - HI4002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M bromide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4002-01\"\u003eBromide ISE 0.1M Standard - HI4002-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280955761,"sku":"HI4002-01","price":11531.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4002-01.jpg?v=1792646043"},{"product_id":"cadmium-half-cell-ion-selective-electrode-ise-hi4003","title":"Cadmium Half-Cell Ion-Selective Electrode (ISE) - HI4003","description":"\u003cp\u003eThe HI4003 cadmium ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed cadmium sulfide\/silver sulfide sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.\u003c\/p\u003e\n\u003cp\u003eHanna's solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4003 to measure cadmium accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the HI4000-00 ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free cadmium ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4003 cadmium solid state ISE can measure from 0.1µM (0.01 mg\/L) to 0.1M (11, 200 mg\/L).\u003c\/p\u003e\n\u003cp\u003eConversion Table for Cd\u003csup\u003e2+\u003c\/sup\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"250\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e1.124 x 10\u003csup\u003e5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e8.896 x 10\u003csup\u003e-6\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Solid state half-cell ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the HI4003 cadmium half-cell by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body of the cadmium half-cell ISE is composed of durable epoxy resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4003 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCadmium Half-Cell Ion-Selective Electrode (ISE) - HI4003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esolid state; half-cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eCadmium (Cd\u003csup\u003e2+\u003c\/sup\u003e) 0.1M to 1 10\u003csup\u003e-7\u003c\/sup\u003eM, 11,200 to 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eepoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 2 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope +28 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4003\" target=\"_blank\" rel=\"noopener\"\u003eCadmium Half-Cell Ion-Selective Electrode (ISE) - HI4003\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280988529,"sku":"HI4003","price":98164.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4003_2016_1.jpg?v=1792646043"},{"product_id":"cadmium-ise-0-1m-standard-hi4003-01","title":"Cadmium ISE 0.1M Standard - HI4003-01","description":"\u003cp\u003eHI4003-01 is a 0.1M standard cadmium solution used to calibrate the cadmium solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4003-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCadmium ISE 0.1M Standard - HI4003-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M cadmium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4003-01\" target=\"_blank\" rel=\"noopener\"\u003eCadmium ISE 0.1M Standard - HI4003-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281054065,"sku":"HI4003-01","price":11531.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4003-01.jpg?v=1792646044"},{"product_id":"calcium-half-cell-ion-selective-electrode-ise-hi4004","title":"Calcium Half-Cell Ion-Selective Electrode (ISE) - HI4004","description":"\u003cp\u003eThe HI4004 calcium ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by an organic polymer sensing PVC membrane. This liquid membrane sensor requires a separate reference electrode to complete the measurement system.\u003c\/p\u003e\n\u003cp\u003eHanna's liquid membrane half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone,  producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4004 to measure calcium accurately,  it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the calcium ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free calcium ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4004 calcium liquid membrane ISE can measure from 3µM (0.12 mg\/L) to 1M (40, 080 mg\/L).\u003c\/p\u003e\n\u003cp\u003eConversion Table for Ca\u003csup\u003e2+\u003c\/sup\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"220\"\u003e\n\u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eMultiply\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003emoles\/L (M) to ppm (mg\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e40080\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eppm (mg\/L) to M (moles\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e2.49 x 10\u003csup\u003e-5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eReplaceable Sensing Modules\u003c\/strong\u003e - Half-cell liquid membrane ISEs are electrodes that detect free ions in a solution. The HI4004 calcium half-cell ISE is designed to incorporate easy replacement of the sensing module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body of the calcium half-cell ISE is composed of durable epoxy resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4004 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA liquid membrane ion selective electrode develops a voltage due to the ion exchange that occurs between the solution and the polymer membrane that contains organic ion exchange resin. When the ionic strength of the solution is fixed by the addition of ISA,  the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Calcium Half-Cell Ion-Selective Electrode (ISE) - HI4004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e polymer membrane; half-cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e Calcium (Ca\u003csup\u003e2+\u003c\/sup\u003e) 1.0M to 3 10\u003csup\u003e-6\u003c\/sup\u003eM, 40,080 to 0.12 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e epoxy, PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e pH 4 to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Approximate Slope +28 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004\"\u003eCalcium Half-Cell Ion-Selective Electrode (ISE) - HI4004\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281119601,"sku":"HI4004","price":99277.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004_2016.jpg?v=1792646045"},{"product_id":"ionic-strength-adjuster-isa-for-calcium-ises-hi4004-00","title":"Ionic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00","description":"\u003cp\u003eHI4004-00 is an ionic strength adjuster (ISA) solution for use with calcium ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-00\"\u003eIonic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281152369,"sku":"HI4004-00","price":12010.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-00.jpg?v=1792646046"},{"product_id":"calcium-ise-0-1m-standard-hi4004-01","title":"Calcium ISE 0.1M Standard - HI4004-01","description":"\u003cp\u003eHI4004-01 is a 0.1M standard calcium solution used to calibrate the calcium liquid membrane ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4004-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCalcium ISE 0.1M Standard - HI4004-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M calcium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4004-01\" target=\"_blank\" rel=\"noopener\"\u003eCalcium ISE 0.1M Standard - HI4004-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281185137,"sku":"HI4004-01","price":11191.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-01.jpg?v=1792646046"},{"product_id":"calcium-ise-conditioning-and-storage-solution-hi4004-45","title":"Calcium ISE Conditioning and Storage Solution - HI4004-45","description":"\u003cp\u003eThe HI4004-45 solution is for the conditioning and storage for the HI4004 and HI4104 calcium liquid membrane ion selective electrodes (ISEs). Measurement of calcium in solutions is determined by calcium ion exchange through the organic polymer membrane. The membrane of the half-cell or combination calcium ISE should be presoaked in HI4004-45 solution for at least one half-hour before calibration to optimize the sensor response. The HI4004-45 is a 500 mL bottle of conditioning and storage solution that ensures optimum measurement performance from the HI4004 and HI4104 calcium ISEs.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Calcium ISE Conditioning and Storage Solution - HI4004-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-45\"\u003eCalcium ISE Conditioning and Storage Solution - HI4004-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281250673,"sku":"HI4004-45","price":10228.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-45.jpg?v=1792646047"},{"product_id":"ionic-strength-adjuster-isa-for-carbon-dioxide-ises-hi4005-00","title":"Ionic Strength Adjuster (ISA) for Carbon Dioxide ISEs - HI4005-00","description":"\u003cp\u003eHI4005-00 is an ionic strength adjuster (ISA) solution for use with carbon dioxide ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Carbon Dioxide ISEs - HI4005-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-00\"\u003eIonic Strength Adjuster (ISA) for Carbon Dioxide ISEs - HI4005-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281283441,"sku":"HI4005-00","price":10939.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-00.jpg?v=1792646048"},{"product_id":"calcium-module-for-half-cell-ise-hi4004-51","title":"Calcium Module for Half-Cell ISE - HI4004-51","description":"\u003cp\u003eThe HI4004-51 calcium module is for use with the HI4004 calcium half-cell ion selective electrode (ISE). The liquid membrane sensor contains an organic polymer within the inert PVC matrix that is responsible for exchange of calcium ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the calcium ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4004-51 calcium half-cell module easily screws onto the HI4004 probe body,  allowing for quick assemblage or replacement. Presoaking the calcium sensor in HI4004-45 conditioning solution or a calcium standard (0.01M) without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4004-51 calcium module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Calcium Module for Half-Cell ISE - HI4004-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-51\"\u003eCalcium Module for Half-Cell ISE - HI4004-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281316209,"sku":"HI4004-51","price":28747.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-51_1.jpg?v=1792646048"},{"product_id":"carbon-dioxide-ise-0-1m-standard-hi4005-01","title":"Carbon Dioxide ISE 0.1M Standard - HI4005-01","description":"\u003cp\u003eHI4005-01 is a 0.1M standard carbon dioxide solution used to calibrate the carbon dioxide gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE 0.1M Standard - HI4005-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M carbon dioxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-01\"\u003eCarbon Dioxide ISE 0.1M Standard - HI4005-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283282289,"sku":"HI4005-01","price":11783.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-01.jpg?v=1792646049"},{"product_id":"carbon-dioxide-ise-1000-ppm-standard-hi4005-03","title":"Carbon Dioxide ISE 1000 ppm Standard - HI4005-03","description":"\u003cp\u003eHI4005-03 is a 1000 ppm (mg\/L) standard solution of carbon dioxide (as CaCO\u003csub\u003e3\u003c\/sub\u003e) used to calibrate the carbon dioxide gas sensing,  combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE 1000 ppm Standard - HI4005-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1000 mg\/L (ppm) carbon dioxide (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-03\"\u003eCarbon Dioxide ISE 1000 ppm Standard - HI4005-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283347825,"sku":"HI4005-03","price":11783.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-03.jpg?v=1792646050"},{"product_id":"carbon-dioxide-ise-filling-solution-hi4005-40","title":"Carbon Dioxide ISE Filling Solution - HI4005-40","description":"\u003cp\u003eThe HI4005-40 fill solution is a chloride ion-containing electrolyte that is required to provide a reference potential for the HI4105 carbon dioxide gas sensing ion selective electrode (ISE). As carbon dioxide diffuses through the gas permeable membrane,  the thin film of electrolyte on the surface of the pH sensing glass undergoes a pH change. The change in pH of the filling solution is proportional to the concentration of carbon dioxide gas in the solution. The HI4005-40 is four bottles of 30 mL carbon dioxide filling solution that ensure optimum measurement performance from the HI4105 carbon dioxide ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE Filling Solution - HI4005-40\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-40\"\u003eCarbon Dioxide ISE Filling Solution - HI4005-40\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283380593,"sku":"HI4005-40","price":13910.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-40.jpg?v=1792646050"},{"product_id":"carbon-dioxide-ise-conditioning-and-storage-solution-hi4005-45","title":"Carbon Dioxide ISE Conditioning and Storage Solution - HI4005-45","description":"\u003cp\u003eThe HI4005-45 solution is for the conditioning and storage for the HI4105 carbon dioxide gas sensing ion selective electrode (ISE). Measurement of carbon dioxide in solutions is determined by a pH change of the internal thin film of electrolyte. This conditioning and storage solution is necessary to keep the glass pH sensing element hydrated in order to accurately determine carbon dioxide concentrations. The HI4005-45 is a 500 mL bottle of conditioning and storage solution that ensures optimum measurement performance from the HI4105 carbon dioxide ISE.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4005-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCarbon Dioxide ISE Conditioning and Storage Solution - HI4005-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4005-45\" target=\"_blank\" rel=\"noopener\"\u003eCarbon Dioxide ISE Conditioning and Storage Solution - HI4005-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283413361,"sku":"HI4005-45","price":8441.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-45.jpg?v=1792646051"},{"product_id":"carbon-dioxide-ise-membrane-kit-3-pcs-hi4005-53","title":"Carbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53","description":"\u003cp\u003eThe HI4005-53 replacement membrane kit contains 3 membrane caps with pre-formed PTFE membranes for the carbon dioxide gas sensing ISE. When the carbon dioxide ISE is first being assembled,  or after a membrane is worn,  the HI4005-53 membrane kit allows for easy assemblage or replacement. By simply screwing on the pre-assembled cap and membrane,  the sensitive PTFE membrane is ensured to remain dry and undamaged for more reliable,  accurate measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 3 membranes\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-53\"\u003eCarbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283446129,"sku":"HI4005-53","price":15594.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-53.jpg?v=1792646051"},{"product_id":"chloride-half-cell-ion-selective-electrode-ise-hi4007","title":"Chloride Half-Cell Ion-Selective Electrode (ISE) - HI4007","description":"\u003cp\u003eThe HI4007 chloride ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed silver chloride sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.\u003c\/p\u003e\n\u003cp\u003eHanna's solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary\u003c\/p\u003e\n\u003cp\u003eFor the HI4007 to measure chloride accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free chloride ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4007 chloride solid state ISE can measure from 50µM (1.8 mg\/L) to 1M (35, 500 mg\/L).\u003c\/p\u003e\n\u003cp\u003eConversion Table for Cl\u003csup\u003e-\u003c\/sup\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"220\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e3.500 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e2.857 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Solid state half-cell ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the HI4007 chloride half-cell by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body of the chloride half-cell ISE is composed of durable epoxy resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4007 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChloride Half-Cell Ion-Selective Electrode (ISE) - HI4007\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esolid state; half-cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eChloride (Cl\u003csup\u003e-\u003c\/sup\u003e) 1.0M to 5 10\u003csup\u003e-5\u003c\/sup\u003eM, 35,500 to 1.8 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eepoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 2 to 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4007\" target=\"_blank\" rel=\"noopener\"\u003eChloride Half-Cell Ion-Selective Electrode (ISE) - HI4007\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283511665,"sku":"HI4007","price":98941.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4007_2016.jpg?v=1792646052"},{"product_id":"chloride-ise-0-1m-standard-hi4007-01","title":"Chloride ISE 0.1M Standard - HI4007-01","description":"\u003cp\u003eHI4007-01 is a 0.1M standard chloride solution used to calibrate the chloride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4007-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Chloride ISE 0.1M Standard - HI4007-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M chloride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4007-01\"\u003eChloride ISE 0.1M Standard - HI4007-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283544433,"sku":"HI4007-01","price":7962.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4007-01.jpg?v=1792646053"},{"product_id":"chloride-ise-100-ppm-standard-hi4007-02","title":"Chloride ISE 100 ppm Standard - HI4007-02","description":"\u003cp\u003eHI4007-02 is a 100 ppm (mg\/L) standard solution of chloride used to calibrate the chloride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4007-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Chloride ISE 100 ppm Standard - HI4007-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 mg\/L (ppm) chloride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4007-02\"\u003eChloride ISE 100 ppm Standard - HI4007-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283577201,"sku":"HI4007-02","price":7962.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4007-02.jpg?v=1792646053"},{"product_id":"chloride-ise-1000-ppm-standard-hi4007-03","title":"Chloride ISE 1000 ppm Standard - HI4007-03","description":"\u003cp\u003eHI4007-03 is a 1000 ppm (mg\/L) standard solution of chloride used to calibrate the chloride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4007-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eChloride ISE 1000 ppm Standard - HI4007-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e1000 mg\/L (ppm) chloride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4007-03\" target=\"_blank\" rel=\"noopener\"\u003eChloride ISE 1000 ppm Standard - HI4007-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283642737,"sku":"HI4007-03","price":7962.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4007-03_1l.jpg?v=1792646054"},{"product_id":"copper-half-cell-ion-selective-electrode-ise-hi4008","title":"Copper Half-Cell Ion Selective Electrode (ISE) - HI4008","description":"\u003cp\u003eThe HI4008 cupric ion selective electrode is a potentiometric half-cell sensor housed within an epoxy body. The internal elements are isolated from the sample by a compressed cupric sulfide\/silver sulfide sensing membrane. This solid state sensor requires a separate reference electrode to complete the measurement system.\u003c\/p\u003e\n\u003cp\u003eHanna's solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4008 to measure cupric ions accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the HI4000-00 ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free cupric ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4008 cupric solid state ISE can measure from 1µM (0.065 mg\/L) to 0.1M (6, 355 mg\/L).\u003c\/p\u003e\n\u003cp\u003eConversion Table for Cu\u003csup\u003e2+\u003c\/sup\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"220\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e6.354 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e1.574 x 10\u003csup\u003e-4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Solid state half-cell ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the HI4008 cupric half-cell by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body of the cupric half-cell ISE is composed of durable epoxy resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4008 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCopper Half-Cell Ion Selective Electrode (ISE) - HI4008\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esolid state; half-cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eCurpic (Cu\u003csup\u003e2+\u003c\/sup\u003e) 0.1M to 1 10\u003csup\u003e-6\u003c\/sup\u003eM, 6,355 to 0.065 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eepoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 3 to 7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope +27 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4008\" target=\"_blank\" rel=\"noopener\"\u003eCopper Half-Cell Ion Selective Electrode (ISE) - HI4008\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283708273,"sku":"HI4008","price":95550.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4008_2016_1.jpg?v=1792646055"},{"product_id":"nitrate-half-cell-ion-selective-electrode-ise-hi4013","title":"Nitrate Half-Cell Ion Selective Electrode (ISE) - HI4013","description":"\u003cp\u003eHanna's liquid membrane half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4013 to measure nitrate accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the nitrate ionic strength adjuster (ISA) solution. The ISA ensures that the activity coefficient is constant so the concentration of free nitrate ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4013 nitrate liquid membrane ISE can measure from 10µM (0.62 mg\/L) to 0.1M (6, 200 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"240\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e62000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e1.61 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eReplaceable Sensing Modules\u003c\/strong\u003e - Half-cell liquid membrane ISEs are electrodes that detect free ions in a solution. This type of ISE is designed to incorporate easy replacement of the sensing module.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body of the nitrate half-cell ISE is composed of durable epoxy resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4013 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA liquid membrane ion selective electrode develops a voltage due to the ion exchange that occurs between the solution and the polymer membrane that contains organic ion exchange resin. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eNitrate Half-Cell Ion Selective Electrode (ISE) - HI4013\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003epolymer membrane; half-cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003enitrate (NO\u003csub\u003e3\u003c\/sub\u003e-) 0.1M to 1 10\u003csup\u003e-5\u003c\/sup\u003eM, 6,200 to 0.62 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eepoxy, PVC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003epH 2 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4013\" target=\"_blank\" rel=\"noopener\"\u003eNitrate Half-Cell Ion Selective Electrode (ISE) - HI4013\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283741041,"sku":"HI4013","price":125239.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013_2016.jpg?v=1792646055"},{"product_id":"ionic-strength-adjuster-isa-for-nitrate-ises-hi4013-00","title":"Ionic Strength Adjuster (ISA) for Nitrate ISEs - HI4013-00","description":"\u003cp\u003eHI4013-00 is an ionic strength adjuster (ISA) solution for use with nitrate ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Nitrate ISEs - HI4013-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-00\"\u003eIonic Strength Adjuster (ISA) for Nitrate ISEs - HI4013-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283773809,"sku":"HI4013-00","price":10228.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-00.jpg?v=1792646056"},{"product_id":"nitrate-module-for-half-cell-ise-3-pcs-hi4013-53","title":"Nitrate Module for Half-Cell ISE (3 pcs) - HI4013-53","description":"\u003cp\u003eThe HI4013-53 nitrate module is for use with the HI4013 nitrate half-cell ion selective electrode (ISE). The liquid membrane sensor contains an organic polymer within the inert PVC matrix that is responsible for exchange of nitrate ions across the membrane. A charge imbalance develops between the sample and the internal cell in response to the nitrate ion activity. The potential change is proportional to the concentration of ions in solution.\u003c\/p\u003e\n\u003cp\u003eThe HI4013-53 nitrate half-cell module easily screws onto the HI4013 probe body,  allowing for quick assemblage or replacement. Presoaking the nitrate sensor in a dilute standard without ionic strength adjuster (ISA) for at least one half hour before calibration will help to optimize the sensor response. Refrigeration of the HI4013-53 nitrate module will help extend its life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate Module for Half-Cell ISE (3 pcs) - HI4013-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 3 modules\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-53\"\u003eNitrate Module for Half-Cell ISE (3 pcs) - HI4013-53\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285248369,"sku":"HI4013-53","price":35138.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-53.jpg?v=1792646057"},{"product_id":"nitrate-ise-0-1m-standard-hi4013-01","title":"Nitrate ISE 0.1M Standard - HI4013-01","description":"\u003cp\u003eHI4013-01 is a 0.1M standard nitrate solution used to calibrate the nitrate liquid membrane ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate ISE 0.1M Standard - HI4013-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-01\"\u003eNitrate ISE 0.1M Standard - HI4013-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285313905,"sku":"HI4013-01","price":9888.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-01.jpg?v=1792646058"},{"product_id":"nitrate-ise-100-ppm-standard-hi4013-02","title":"Nitrate ISE 100 ppm Standard - HI4013-02","description":"\u003cp\u003eHI4013-02 is a 100 ppm (mg\/L) standard solution of nitrate (as NO\u003csub\u003e3\u003c\/sub\u003e-N) used to calibrate the nitrate liquid membrane combination ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4013-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrate ISE 100 ppm Standard - HI4013-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 100 mg\/L (ppm) nitrate (as NO\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4013-02\"\u003eNitrate ISE 100 ppm Standard - HI4013-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285346673,"sku":"HI4013-02","price":9888.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4013-02.jpg?v=1792646058"}],"url":"https:\/\/hannainst.in\/collections\/parameter-ise.oembed?page=3","provider":"hanna","version":"1.0","type":"link"}