{"title":"Salinity","description":"","products":[{"product_id":"marine-salinity-waterproof-tester-hi98319","title":"Marine Salinity Waterproof Tester - HI98319","description":"\u003ch2\u003eFeatures\u003c\/h2\u003e\n\u003cp\u003eSalinity measurements calculated from a conductivity measurement using known tables\u003c\/p\u003e\n\u003cp\u003eChoice of measurement units displayed in parts per thousand (ppt), Practical Salinity Units (PSU), or specific gravity (S.G.)\u003c\/p\u003e\n\u003cp\u003eAutomatic Temperature Compensation (ATC), displays temperature in ℃ or ℉\u003c\/p\u003e\n\u003cp\u003eAmperometric graphite sensor reduces polarization effects and does not oxidize\u003c\/p\u003e\n\u003cp\u003eLarge LCD displays stability indicator, low-battery indicator, and calibration tags\u003c\/p\u003e\n\u003cp\u003eDedicated calibration button with automatic recognition of the 35.00 ppt calibration solution in calibration mode\u003c\/p\u003e\n\u003cp\u003eSupplied complete with meter and calibration sachets in a durable plastic storage case.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Salinity Waterproof Tester - HI98319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 70.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1 ppt for 0.0 to 40.0 ppt; ±2 ppt for readings over 40.0 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003eall ranges calibrated with 35.00 ppt salinity standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 70.0 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 PSU for 0.0 to 40.0 PSU ; ±2 PSU for readings over 40.0 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Range\u003c\/td\u003e\n\u003ctd\u003e1.000 to 1.041 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpecific Gravity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.001 S.G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5.0 to 50.0°C (41.0 to 122.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Method\u003c\/td\u003e\n\u003ctd\u003eppt - International Oceanographic Tables, 1966\nPSU - Standard Methods for the Examination of Water and Wastewater, 2520 B, Electrical Conductivity Method\nStandard Methods for the Examination of Water and Wastewater, 2520 C, Density Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0°C; 32.0 to 122.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C; ±1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable 8 minutes, 60 minutes, or disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eCR2032 3V lithium ion \/ approximately 100 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e160 x 40 x 17 mm (6.3 x 1.6 x 0.7“)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e68 g (2.4 oz.) without battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98319 is supplied with protective cap, 35.00 ppt calibration solution sachet (4), CR2032 battery (1), plastic storage case, instrument quality certificate and instructional manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98319\" target=\"_blank\" rel=\"noopener\"\u003eMarine Salinity Waterproof Tester - HI98319\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871121965425,"sku":"HI98319","price":9363.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98319-angle-c.jpg?v=1792645678"},{"product_id":"waterproof-portable-ec-tds-resistivity-salinity-meter-hi98192","title":"Waterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI98192 is supplied with the HI763133 four-ring conductivity probe with a built-in temperature sensor. This technology allows for accurate readings that cover a complete range with a single sensor. The four ring technology also eliminates the polarization effect that is common with standard two pole versions. The HI763133 conductivity probe connects to the meter with a unique quick connect waterproof DIN connector allowing for a secure attachment without a threaded connection that is also easy to remove.\u003c\/p\u003e\n\u003cp\u003eHI98192 has an expanded conductivity range from 0.000 µS\/cm to 1000 mS\/cm actual conductivity (400 mS\/cm temperature compensated). The HI98192 also has ranges for TDS, resistivity, and three salinity scales. This meter automatically recognizes the probe type (two or four ring) and allows the user to adjust the nominal cell constant.\u003c\/p\u003e\n\u003cp\u003eHI98192 can be used to perform all three stages of USP method required for EC measurement of ultrapure water and generates a report when the any of the three stages are met.\u003c\/p\u003e\n\u003cp\u003eChoose from seven memorized standards and obtain up to a five point conductivity calibration. For salinity (% range), HI7037 standard allows users to make a one point calibration.\u003c\/p\u003e\n\u003ch5\u003eEC and TDS measurements are fully customizable and include:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eCell constant selection between 0.0 and 10.000\u003c\/li\u003e\n\u003cli\u003eSelection of linear or non-linear (natural water), or No temperature compensation\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe temperature compensation coefficient range is configurable from 0.00 to 10.00%\/℃ with a choice of reference temperatures of 15℃, 20℃ and 25℃. The conductivity to TDS factor is adjustable from 0.40 and 1.00.\u003c\/p\u003e\n\u003cp\u003eThe HI98192 allows for the creation of 10 measurement profiles with various user settings including temperature compensation, range selection, cell constant, and TDS conversion factors.\u003c\/p\u003e\n\u003cp\u003eThe log-on-demand mode allows the user to record and save up to 400 readings while the lot logging at selected intervals can store up to 1000 readings. This data can then be transferred to a PC with Hanna’s HI920015 micro USB cable and HI92000 software.\u003c\/p\u003e\n\u003cp\u003eGLP data includes date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS) is directly accessible by pressing the dedicated GLP key.\u003c\/p\u003e\n\u003cp\u003eAccess help at any time at the press of a dedicated button and view content specific information based on the screen that is currently being viewed.\u003c\/p\u003e\n\u003cp\u003eThe compact, durable HI720192 carry case is thermoformed to hold all necessary components for taking a field measurement, including the meter, probe, beakers and conductivity standards.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-1.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eThree stages of conformity\u003c\/strong\u003e\nPerforms all 3 stages of USP water quality testing requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-2-guide.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eOn-screen guide\u003c\/strong\u003e\nUsers are provided with on-screen instructions for each USP stage\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98192-USP-2-progress.jpg\" alt=\"USP 2 progress\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eProgress bar\u003c\/strong\u003e\nDisplays progress towards meeting stage 2 stability requirements.\u003c\/p\u003e\n\u003ch4\u003eFeatures\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eCompact, rugged, waterproof (IP67) design\u003c\/h5\u003e\n\u003ch5\u003eMethods\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eUSP \u0026lt;645\u0026gt; capable for checking the quality of water used in pharmaceutical manufacturing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eSalinity readings\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eSeawater salinity can be displayed as % NaCl, natural seawater scale (ppt) or practical salinity scale (PSU)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eAuto-ranging and fixed range options\u003c\/h5\u003e\n\u003ch5\u003eCalibration\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePerform up to a five point calibration for enhanced accuracy\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eGLP Features\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eGLP data provides calibration data including date, time, standards used, temperature compensation used, reference temperature, and TDS conversion factor (TDS)\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration timeout to alert the user at a defined interval when the calibration has expired\u003c\/strong\u003e\u003c\/p\u003e\n\u003ch5\u003eAuto Hold\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eFreezes first stable reading on the display\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMultiple language selection\u003c\/h5\u003e\n\u003ch5\u003eTemperature compensation\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eNo temperature compensation, linear temperature compensation and non-linear temperature compensation – ISO\/DIN 7888\u003c\/li\u003e\n\u003cli\u003eConfigurable linear temperature compensation coefficient range from 0.00 to 10.00%\/℃\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eData logging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLog on Demand: Store measurement data at the press of a button\u003c\/li\u003e\n\u003cli\u003eInterval lot logging: Log measurements at a selectable interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via opto-isolated USB with optional HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003e100-hour battery life\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eApproximately 100 hours of continuous use (without backlight)\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMenu driven for ease of use with virtual-key extended functionality\u003c\/h5\u003e\n\u003ch5\u003eContextual help at the press of a button\u003c\/h5\u003e\n\u003ch5\u003eBacklit, Graphic LCD\u003c\/h5\u003e\n\u003ch5\u003eConnectivity\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePC connectivity via a sealed opto-isolated micro USB and HI92000 software\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003ePRIMARY APPLICATIONS: Environmental, pharmaceutical, plating, water treatment, food manufacturing, and water and wastewater\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/l18xilr9j4?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/b47438229e5b7d8641acbd496846c11c50147bcf.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWaterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 µS\/cm*; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm (actual conductivity; temperature compensated to 400 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.01 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic up to five points with seven memorized standards (0.00 µS\/cm, 84.0 µS\/cm, 1.413 mS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt (g\/L); 10.00 to 99.99 ppt (g\/L); 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm; 0.1 ppm; 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 mg\/L (ppm) or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003enoTC, Linear (-20 to 120 °C; -4 to 248°F), Non Linear - ISO\/DIN 7888 (-0 to 36 °C; 32 to 96.8°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 1.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Temperature\u003c\/td\u003e\n\u003ctd\u003e15°C, 20°C and 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Multi-range Measurement Modes\u003c\/td\u003e\n\u003ctd\u003eautorange, autoend, lock and fixed range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003emax. one point only in % range (with HI7037 standard)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 (PSU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 80.00 (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω cm; 100 to 999 Ω cm; 1.00 to 9.99 KΩ cm; 10.0 to 99.9 KΩ cm; 100 to 999 KΩ cm; 1.00 to 9.99 MΩ cm; 10.0 to 100.0 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω cm; 1 Ω cm; 0.01 KΩ cm; 0.1 KΩ cm; 1 KΩ cm; 0.01 MΩ cm; 0.1 MΩ cm*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±10 Ω or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C (-4.0 to 248.0°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2°C; ±0.4°F (excluding probe error)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e\n\u003ctd\u003eHI763133, four ring conductivity\/TDS probe with internal temperature sensor and 4 m (13.2’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand: 400 samples; lot logging: 5, 10, 30 sec, 1, 2, 5, 10, 15, 30, 60, 120, 180 min (max 1000 samples)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eopto-isolated USB with optional HI 92000 software and micro USB cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003euser selectable: 5, 10, 30, 60 min or can be disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.5V AA batteries (4) \/ approximately 100 hours of continuous use (without backlight), 25 hours with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH 100% (IP67)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e400 g (14.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI98192 is supplied with HI763133 conductivity probe, HI7031M 1413 µS\/cm calibration solution (230 mL), HI7035M 111.8 mS\/cm calibration solution (230 mL), 100 mL plastic beaker (2), HI92000 PC software, HI920015 micro USB cable, 1.5V AA batteries (4), instruction manual, quick start guide, quality certificate and HI720192 rugged carrying case.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98192\" target=\"_blank\" rel=\"noopener\"\u003eWaterproof Portable EC\/TDS\/Resistivity\/Salinity Meter - HI98192\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170396529,"sku":"HI98192","price":103693.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi98192_manual_1.jpg?v=1792645815"},{"product_id":"stainless-steel-cover-magnetic-mini-stirrer-hi200m","title":"Stainless Steel Cover Magnetic Mini-Stirrer - HI200M-2","description":"\u003cp\u003eIdeally,  when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing and the sample to be homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI200M mini-magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI200M magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI200M stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab,  a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI200M magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With \u003cstrong\u003eSpeedsafe™\u003c\/strong\u003e,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI200M is equipped with a replaceable fuse. The circuitry of the HI200M is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI200M-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Stainless Steel Cover Magnetic Mini-Stirrer - HI200M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 120 x 120 x 45 mm (4.8 x 4.8 x 1.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 710 g (1.6 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI200M magnetic mini-stirrer is supplied with micro stir bar (1) and instructions\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI200M-1\"\u003eStainless Steel Cover Magnetic Mini-Stirrer - HI200M\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235047793,"sku":"HI200M-2","price":9610.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi200m-front.jpg?v=1792645911"},{"product_id":"magnetic-stir-bars-10-hi731319","title":"Magnetic Stir Bars (10) - HI731319","description":"\u003cp\u003eThe HI731319 set of 10 magnetic stir bars made for a variety of applications. Used in a laboratory setting,  a magnetic stirrer together with magnetic stir bars continually stir buffers and\/or samples to keep them homogeneous. By keeping samples uniform during measurement and titration,  erroneous results are eliminated by preventing any temperature gradients or inadequate mixing when chemicals are added to a sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Magnetic Stir Bars (10) - HI731319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 25 mm x 7 mm \/ 1” x 0.3”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eQuantity: 10\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731319\"\u003eMagnetic Stir Bars (10) - HI731319\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871235277169,"sku":"HI731319","price":8250.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731319.jpg?v=1792645914"},{"product_id":"heavy-duty-stainless-steel-cover-mini-stirrer-2-5l-hi300n-1","title":"Heavy-Duty Stainless Steel Cover Mini-Stirrer (2.5L) - HI300N-1 - HI300N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing,  ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI300N magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI300N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI300N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI300N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI300N is equipped with a replaceable fuse. The circuitry of the HI300N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI300N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Heavy-Duty Stainless Steel Cover Mini-Stirrer (2.5L) - HI300N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI300N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI300N-1\"\u003eHeavy-Duty Stainless Steel Cover Mini-Stirrer (2.5L) - HI300N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248646513,"sku":"HI300N-2","price":16640.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi300n_v2_1.jpg?v=1792645932"},{"product_id":"auto-reverse-stainless-steel-cover-mini-stirrer-2-5l-hi302n-1","title":"Auto-Reverse Stainless Steel Cover Mini-Stirrer (2.5L) - HI302N-1 - HI302N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements, the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing, ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI302N magnetic stirrer is compact and lightweight, allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable, space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI302N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eAdjustable Auto Reverse\u003c\/h5\u003e\n\u003cp\u003eHI302N stirrer has an adjustable auto-reverse setting. A reverse period knob allows the user to adjust the reverse interval from 30 seconds to 3 minutes. Once the interval time is set, the fluid will rotate in one direction for that amount of time and then reverse its rotation for that same amount of time, all at the desired speed in a repeated cycle until the stirrer is switched off.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI302N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI302N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe, a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level, the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load of glory is suddenly removed from the stirrer, the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety, in the event of a short circuit, the HI302N is equipped with a replaceable fuse. The circuitry of the HI302N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI302N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAuto-Reverse Stainless Steel Cover Mini-Stirrer (2.5L) - HI302N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI302N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI302N-1\" target=\"_blank\" rel=\"noopener\"\u003eAuto-Reverse Stainless Steel Cover Mini-Stirrer (2.5L) - HI302N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248712049,"sku":"HI302N-2","price":17731.0,"currency_code":"INR","in_stock":true}]},{"product_id":"auto-reverse-stainless-steel-cover-mini-stirrer-with-tachometer-2-5l-hi304n-1","title":"Auto-Reverse Stainless Steel Cover Mini-Stirrer with Tachometer (2.5L) - HI304N-1 - HI304N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing,  ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI304N magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI304N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eAdjustable Auto Reverse\u003c\/h5\u003e\n\u003cp\u003eHI304N stirrer has an adjustable auto-reverse setting. A reverse period knob allows the user to adjust the reverse interval from 30 seconds to 3 minutes. Once the interval time is set,  the fluid will rotate in one direction for that amount of time and then reverse its rotation for that same amount of time,  all at the desired speed in a repeated cycle until the stirrer is switched off.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Tachometer\u003c\/h5\u003e\n\u003cp\u003eHI304N stirrer has a built-in 4-digit LCD tachometer that shows the stirring speed in RPM for ultimate accuracy.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI304N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI304N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI304N is equipped with a replaceable fuse. The circuitry of the HI304N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI304N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Auto-Reverse Stainless Steel Cover Mini-Stirrer with Tachometer (2.5L) - HI304N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI304N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI304N-1\"\u003eAuto-Reverse Stainless Steel Cover Mini-Stirrer with Tachometer (2.5L) - HI304N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248744817,"sku":"HI304N-2","price":18844.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi304_v2.jpg?v=1792645933"},{"product_id":"heavy-duty-stainless-steel-cover-mini-stirrer-with-autospeed-5-l-hi310n-1","title":"Heavy-Duty Stainless Steel Cover Mini-Stirrer with Autospeed (5 L) - HI310N-1 - HI310N-2","description":"\u003cp\u003eIdeally when performing electrochemistry measurements,  the sample being tested should be stirred. The use of a magnetic stirrer allows for proper mixing,  ensuring that the sample is homogenous in consistency and temperature. The stirring of the sample also helps speed up the response time for a sensor to achieve a stable reading.\u003c\/p\u003e\n\u003ch5\u003eCompact \u0026amp; Cost-Effective\u003c\/h5\u003e\n\u003cp\u003eThe HI310N magnetic stirrer is compact and lightweight,  allowing for easy handling in the laboratory environment. Limited area on laboratory benchtops is no longer a concern with this durable,  space-saving stirrer. Power-indicating LED lights also assure users at a distance that the stirrer is in operation. The durable plastic covering will resist harmful effects of accidentally spilled chemicals. The HI310N magnetic mini-stirrer is cost-effective for the customer that does not need the added expense of a heating element. The advanced design incorporates electronic controls that allow the user to easily regulate the speed with great precision.\u003c\/p\u003e\n\u003ch5\u003eStainless Steel Cover\u003c\/h5\u003e\n\u003cp\u003eHI310N stirrer comes supplied with an AISI 316 stainless steel cover atop the ABS body. The cover is an ideal solution for applications in which exothermic reactions occur. The AISI 316 type of steel is known to have increased resistance to chloride corrosion as well.\u003c\/p\u003e\n\u003ch5\u003eSpeedsafe™\u003c\/h5\u003e\n\u003cp\u003eOften in the lab a sample is removed from a stirrer before the speed is adequately reduced. Normally this would cause the internal motor to accelerate until it is damaged. To control the speed from changes in viscosity or removing of the load the HI310N magnetic mini-stirrer incorporates the Speedsafe™ mechanism. With Speedsafe,  a speed sensing device (opto-sensor) is coupled with an FVC (frequency voltage converter) to monitor the stirring speed. As the speed reaches a preset maximum level,  the speed limiter shuts down the VCO (voltage-controlled oscillator) to slow down the motor speed. This ensures that when the load is suddenly removed from the stirrer,  the motor will not accelerate to such a high speed that will be hazardous to both the user and the stirrer; a feature not commonly found in conventional stirrers.\u003c\/p\u003e\n\u003ch5\u003eFuse Protection\u003c\/h5\u003e\n\u003cp\u003eFor safety,  in the event of a short circuit,  the HI310N is equipped with a replaceable fuse. The circuitry of the HI310N is grounded to the case for additional protection\u003c\/p\u003e\n\u003ch5\u003eAutospeed\u003c\/h5\u003e\n\u003cp\u003eFor Non-newtonian fluids like oil and clay,  the viscosity changes during the stirring process,  making it necessary to adjust the power to maintain a constant speed during the stirring. Hanna Auto-Speed stirrers are designed with automatic feedback control to maintain constant speed when the torque load changes and are therefore ideal for stirring non-Newtonian fluids where the viscosity changes during stirring. They are also ideal for mixing applications where one solution is added to another which changes the capacity and thereby the torque load on the stirrer. The Auto-Speed stirrers maintain a constant stirring speed during the mixing up to the full capacity of 5 liters. They can also be used with Newtonian fluids up to a capacity of 5 liters.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI310N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Heavy-Duty Stainless Steel Cover Mini-Stirrer with Autospeed (5 L) - HI310N-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 180 x 180 x 70 mm (7.1 x 7.1 x 2.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.4 kg (3.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI310N magnetic mini-stirrer is supplied with micro stir bar (1) and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI310N-1\"\u003eHeavy-Duty Stainless Steel Cover Mini-Stirrer with Autospeed (5 L) - HI310N-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248810353,"sku":"HI310N-2","price":18844.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi310_v2.jpg?v=1792645934"},{"product_id":"marine-test-kit-hi3823","title":"Marine Test Kit - HI3823","description":"\u003cp\u003eThe HI3823 is a chemical test kit that uses titration and direct measurement to measure six parameters common in aquaculture testing: alkalinity, carbon dioxide, hardness, dissolved oxygen, pH, and salinity. The HI3823 is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents are individually available as they run out.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the pH tester, sample beaker, indicator and reagent bottles and packets, and glass bottle for dissolved oxygen.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eThe six most important parameters in aquaculture applications can be monitored with this combination chemical test kit. They include: alkalinity, carbon dioxide, dissolved oxygen, hardness, pH, and salinity. This kit is ideal not only for professionals, but also for educators and students studying marine science, as it offers great performance and ease of use. HI3823 is equipped with all the accessories and reagents to perform over 100 tests for each parameter. The pHep®, our popular pH electronic tester, is included for your convenience. This small and easy to use pH meter will provide more accurate and reliable pH readings than conventional litmus paper. The pHep® also has the added benefit of introducing students to the use of a pH meter.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMarine Test Kit - HI3823\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003eelectronic pH tester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 14.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, two points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003elife of the meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003emodified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L CO₂; 0.0 to 50.0 mg\/L CO₂; 0 to 100 mg\/L CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (0.0 to 10.0 mg\/L range); 0.5 mg\/L (0.0 to 50.0 mg\/L range); 1 mg\/L (0 to 100 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.4 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Method\u003c\/td\u003e\n\u003ctd\u003emercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e2.3 kg (5.1 lb)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e440 x 330 x 100 mm (17.3 x 13.0 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3823 test kit includes all of the necessary reagents and accessories to perform over 100 tests for every parameter, electronic pH tester, hard carrying case, and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3823\" target=\"_blank\" rel=\"noopener\"\u003eMarine Test Kit - HI3823\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871262048625,"sku":"HI3823","price":53805.6,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3823.jpg?v=1792645985"},{"product_id":"salinity-chemical-test-kit-hi3835","title":"Salinity Chemical Test Kit - HI3835","description":"\u003cp\u003eThe HI3835 is a titration-based chemical test kit that measures salinity within the 0.0 to 40.0 g\/kg range. The HI3835 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 110 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the sample vial,  indicator and reagent bottles,  and calibrated syringe.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eReadings from 0 to 40 g\/kg are determined to 4 g\/kg resolution for each 0.1 ml of titrant added.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3835-100 can be ordered to replace the reagents supplied with the kit.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eSalinity is defined as the total solids in water after all carbonates have been converted to oxides,  all bromide and iodide have been replaced by chloride,  and all organic matter has been oxidized. The salinity value is in g\/kg or ppt (parts per thousand). The monitoring of salinity is essential for industrial waste and seawater,  as different species of plants and animals thrive varying salinity levels.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3835\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Salinity Chemical Test Kit - HI3835\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003e titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 40 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e 4 g\/kg for each 0.1 ml of titrant\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Method\u003c\/td\u003e\n\u003ctd\u003e mercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 460 g (17.2 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 200x120x60 mm (7.9x4.7x2.4 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3835 test kit comes with 15 mL diphenyl-carbazone indicator, 30 mL nitric acid solution, 120 mL titrant solution, plastic vial, and 1 mL calibrated syringe with tip.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3835\"\u003eSalinity Chemical Test Kit - HI3835\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871269585265,"sku":"HI3835","price":8925.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3835_2.jpg?v=1792646001"},{"product_id":"salinity-chemical-test-kit-replacement-reagents-110-tests-hi3835-100","title":"Salinity Chemical Test Kit Replacement Reagents (110 tests) - HI3835-100","description":"\u003cp\u003eThe HI3835-100 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate salinity measurements with the chemical test kit. These reagents follow the mercuric nitrate method to determine salinity concentration.\u003c\/p\u003e\n\u003cp\u003eFor determination of salinity,  the pH of the sample is adjusted to approximately pH 3 with the nitric acid reagent,  turning the solution yellow. The mercuric ions present in the titrant react with chloride in the sample. Once all of the chloride is in the mercuric chloride form,  excess mercuric ions are present,  forming a purple complex with the diphenylcarbazone indicator. The number of milliliters of titrant used to change the solution’s color from yellow to purple will determine the salinity in g\/kg (ppt). These reagents are designed to be used with samples that have an expected salinity range of 0 to 40 g\/kg (ppt).\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3835-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Salinity Chemical Test Kit Replacement Reagents (110 tests) - HI3835-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 110 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e mercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3835-100\"\u003eSalinity Chemical Test Kit Replacement Reagents (110 tests) - HI3835-100\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871269552497,"sku":"HI3835-100","price":6659.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3835-100-1200by1200-rgb.jpg?v=1792646001"},{"product_id":"backpack-lab-marine-science-educational-test-kit-hi3899bp","title":"Backpack Lab Marine Science Educational Test Kit - HI3899BP","description":"\u003cp\u003eThe HI3899BP is a classroom in a backpack! The Backpack Lab Marine Science Educational Test Kit contains lessons, activities, and test kits to help students understand the importance of common marine science parameters. Using titration, colorimetry, and direct measurement, educators and students can easily measure parameters such as acidity, alkalinity, ammonia, carbon dioxide, dissolved oxygen, nitrite, nitrate, phosphate, salinity, specific gravity, turbidity, pH, EC, TDS, and temperature. The HI3899BP is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents and buffers are individually available as they run out.\u003c\/p\u003e\n\u003cp\u003eHanna chemical test kits and pocket testers included in this Backpack Lab provide teachers with a valuable tool in helping students address important topics and practices in marine science. The teacher's guide provides detailed background information for marine science lessons\/activities that can be adapted to various grade levels. Real-world examples help students understand the relevance of nutrients and physical characteristics of our oceans.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003e Tests for 15 important marine science parameters \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eClassrooms can gain an extensive understanding of marine science through measurement of these fifteen parameters:\nAcidity, alkalinity, ammonia, carbon dioxide, dissolved oxygen, nitrite, nitrate, phosphate, salinity, specific gravity, turbidity, pH, EC, TDS, and temperature.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete testing setup\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the pH tester, secchi disk, hydrometer, and indicator and reagent bottles and packets.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents and buffers for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive educational material\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThe lesson plan and components are tied together by a comprehensive teacher's manual that includes information about each parameter, classroom activities designed to introduce students to each parameter, and detailed field-testing procedures.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3899BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eBackpack Lab Marine Science Educational Test Kit - HI3899BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at 1382 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003emodified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 500 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L ; 5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Method\u003c\/td\u003e\n\u003ctd\u003emethyl orange \/ phenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L ; 3 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 2.5 mg\/L NH₃-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e0.5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L CO₂; 0.0 to 50.0 mg\/L CO₂; 0 to 100 mg\/L CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L ; 0.5 mg\/L ; 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 50 mg\/L NO₃⁻-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003ecadmium reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 1.0 mg\/L NO₂⁻-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003e0.2 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003echromotropic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mg\/L PO₄³⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Number of Test\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.4 g\/kg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Method\u003c\/td\u003e\n\u003ctd\u003emercuric nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3899BP Backpack Lab includes acidity test kit, alkalinity test kit, carbon dioxide test kit, ammonia test kit, dissolved oxygen test kit, nitrate test kit, nitrite test kit, phosphate test kit, salinity test kit, secchi disc, hydrometer, HI98129 Combo pH\/EC\/TDS\/temperature tester, set of 6 field test procedures, teacher’s resource CD, teacher’s guide, and backpack.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3899BP\" target=\"_blank\" rel=\"noopener\"\u003eBackpack Lab Marine Science Educational Test Kit - HI3899BP\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276433777,"sku":"HI3899BP","price":73877.4,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3899bp-marine-backpack-lab_1200x1200_72_rgb.jpg?v=1792646027"},{"product_id":"halide-polishing-strips-24-pcs-hi4000-70","title":"Halide Polishing Strips (24 pcs) - HI4000-70","description":"\u003cp\u003eThe HI4000-70 is a pack of 24 halide polishing strips. A scratched,  pitted,  or oxidized sensing surface can be restored with HI4000-70 polishing strip. The user simply needs a small portion of the micro abrasive strip to polish a solid state membrane. By wetting the frosted side with purified water,  the polishing strip gently reconditions the sensing surface. A worn pellet surface can cause drift,  decreased sensitivity at low concentration levels,  or poor repeatability between measurements. Optimum ISE response can be restored by removing the damaged surface with the HI4000-70 polishing strips.\u003c\/p\u003e\n\u003cp\u003eHI4000-70 is made for use on the following ion selective electrodes:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI4002 \/ HI4102 Bromide ISE\u003c\/li\u003e\n\u003cli\u003eHI4003 \/ HI4103 Cadmium ISE\u003c\/li\u003e\n\u003cli\u003eHI4007 \/ HI4107 Chloride ISE\u003c\/li\u003e\n\u003cli\u003eHI4008 \/ HI4108 Cupric ISE\u003c\/li\u003e\n\u003cli\u003eHI4009 \/ HI4109 Cyanide ISE\u003c\/li\u003e\n\u003cli\u003eHI4011 \/ HI4111 Iodide ISE\u003c\/li\u003e\n\u003cli\u003eHI4012 \/ HI4112 Lead\/Sulfate ISE\u003c\/li\u003e\n\u003cli\u003eHI4015 \/ HI4115 Silver\/Sulfide ISE\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Halide Polishing Strips (24 pcs) - HI4000-70\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 24 strips\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-70\"\u003eHalide Polishing Strips (24 pcs) - HI4000-70\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280857457,"sku":"HI4000-70","price":4450.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-70.jpg?v=1792646041"},{"product_id":"35-00-ppt-marine-salinity-calibration-standard-25-x-20-ml-hi70024p","title":"35.00 ppt Marine Salinity Calibration Standard (25 x 20 ml) - HI70024P","description":"\u003cp\u003eHI70024P is a premium quality 35.00 ppt marine salinity solution standardized with a conductivity meter that has been calibrated with  potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696\/BS3978.  Additional equipment used in preparation of the solutions include certified weight-checked balances,  Class A glassware and certified thermometers.\u003c\/p\u003e\n\u003ch5\u003eConvenience of individual packaging\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for users that do not calibrate frequently\u003c\/li\u003e\n\u003cli\u003eIdeal for field use due to portability\u003c\/li\u003e\n\u003cli\u003eEvery sachet is as fresh as the day it was packaged\u003c\/li\u003e\n\u003cli\u003eLight block packaging prevents oxidation from UV light that could alter the value\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eEach sachet marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70024P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 35.00 ppt Marine Salinity Calibration Standard (25 x 20 ml) - HI70024P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Marine Salinity Calibration Standard  for HI98319\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConcentration\u003c\/td\u003e\n\u003ctd\u003e 35.00 ppt @ 25°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e single use sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 ml\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70024P\"\u003e35.00 ppt Marine Salinity Calibration Standard (25 x 20 ml) - HI70024P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871330435441,"sku":"HI70024P","price":3796.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/solution-sachet.jpg?v=1792646168"},{"product_id":"silver-nitrate-0-1m-1l-hi70422","title":"Silver Nitrate 0.1M,  1L - HI70422","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Silver Nitrate 0.1M, 1L - HI70422\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Silver Nitrate 0.1 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 1 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70422\"\u003eSilver Nitrate 0.1M, 1L - HI70422\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871355797873,"sku":"HI70422","price":13313.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70422.jpg?v=1792646235"},{"product_id":"nitric-acid-solution-1-5m-500-ml-hi70427","title":"Nitric Acid Solution 1.5M,  500 mL - HI70427","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitric Acid Solution 1.5M, 500 mL - HI70427\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Nitric Acid Solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1.5 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70427\"\u003eNitric Acid Solution 1.5M, 500 mL - HI70427\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871358222705,"sku":"HI70427","price":2750.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70427.jpg?v=1792646239"},{"product_id":"nitric-acid-solution-1m-500-ml-hi70445","title":"Nitric Acid Solution 1M,  500 mL - HI70445","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitric Acid Solution 1M, 500 mL - HI70445\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Nitric Acid Solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 1 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70445\"\u003eNitric Acid Solution 1M, 500 mL - HI70445\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871364252017,"sku":"HI70445","price":2750.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70445.jpg?v=1792646252"},{"product_id":"silver-nitrate-0-02m-1l-hi70448","title":"Silver Nitrate 0.02M,  1L - HI70448","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Silver Nitrate 0.02M, 1L - HI70448\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Silver Nitrate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.02 M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 1 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70448\"\u003eSilver Nitrate 0.02M, 1L - HI70448\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871365136753,"sku":"HI70448","price":4790.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70448-1200by1200-rgb.jpg?v=1792646254"},{"product_id":"30-g-l-sodium-chloride-standard-solution-500-ml-hi7081l","title":"30 g\/L Sodium Chloride Standard Solution,  500 mL - HI7081L","description":"\u003cp\u003eHI7081L is a premium quality 30 g\/L sodium chloride (NaCl) calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7081L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 30 g\/L Sodium Chloride Standard Solution, 500 mL - HI7081L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 30 mg\/L NaCl \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7081L\"\u003e30 g\/L Sodium Chloride Standard Solution, 500 mL - HI7081L\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369593201,"sku":"HI7081L","price":2410.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7081l_box.jpg?v=1792646296"},{"product_id":"isa-solution-for-sodium-ise-230-ml-hi7090m","title":"ISA Solution for Sodium ISE (230 mL) - HI7090M","description":"\u003cp\u003eHI7090M is a premium quality ISA solution produced in accordance with ISO 3696\/BS3978 standards using high purity reagents,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7091L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7091L Pretreatment Reducing Solution for ORP electrodes (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e reducing pretreatment solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7091L\"\u003eHI7091L Pretreatment Reducing Solution for ORP electrodes (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369658737,"sku":"HI7090M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/230-ml-light_29_1_1_1_1_1_1_1_1_1_1_1.png?v=1792646298"},{"product_id":"5-84-g-l-nacl-standard-solution-in-fda-bottle-500-ml-hi8088l","title":"5.84 g\/L NaCl Standard Solution in FDA Bottle (500 mL) - HI8088L","description":"\u003cp\u003eHI8088L is a premium quality 5.84 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI8088L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI8088L 5.84 g\/L NaCl Standard Solution in FDA Bottle (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 5.84 g\/L NaCl \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFDA Bottle\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI8088L\"\u003eHI8088L 5.84 g\/L NaCl Standard Solution in FDA Bottle (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369691505,"sku":"HI8088L","price":3796.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi8088.jpg?v=1792646298"},{"product_id":"58-4-g-l-nacl-standard-solution-230-ml-bottle-hi7084m","title":"58.4 g\/L NaCl Standard Solution (230 mL Bottle) - HI7084M","description":"\u003cp\u003eHI7084M is a premium quality 58.4 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7084M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7084M 58.4 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 58.4 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7084M\"\u003eHI7084M 58.4 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369724273,"sku":"HI7084M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7084m_box.jpg?v=1792646298"},{"product_id":"0-3-g-l-nacl-standard-solution-230-ml-bottle-hi7085m","title":"0.3 g\/L NaCl Standard Solution (230 mL Bottle) - HI7085M","description":"\u003cp\u003eHI7085M is a premium quality 0.3 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7085M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7085M 0.3 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.3 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7085M\"\u003eHI7085M 0.3 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369789809,"sku":"HI7085M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7086m.jpg?v=1792646300"},{"product_id":"5-84-g-l-nacl-standard-solution-230-ml-bottle-hi7088m","title":"5.84 g\/L NaCl Standard Solution (230 mL Bottle) - HI7088M","description":"\u003cp\u003eHI7088M is a premium quality 5.84 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7088M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7088M 5.84 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 5.84 g\/L NaCl \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7088M\"\u003eHI7088M 5.84 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369822577,"sku":"HI7088M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/230-ml-light_29_1_1_1_1_1_1_1_1_1_1.png?v=1792646300"},{"product_id":"125-g-l-nacl-standard-solution-230-ml-bottle-hi7089m","title":"125 g\/L NaCl Standard Solution (230 mL Bottle) - HI7089M","description":"\u003cp\u003eHI7089M is a premium quality 125 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7089M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7089M 125 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 125 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7089M\"\u003eHI7089M 125 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369855345,"sku":"HI7089M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7089m_box.jpg?v=1792646300"},{"product_id":"3-0-g-l-nacl-standard-solution-230-ml-bottle-hi7083m","title":"3.0 g\/L NaCl Standard Solution (230 mL Bottle) - HI7083M","description":"\u003cp\u003eHI7083M is a premium quality 3.0 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7083M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7083M 3.0 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 3.0 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7083M\"\u003eHI7083M 3.0 g\/L NaCl Standard Solution (230 mL Bottle)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369920881,"sku":"HI7083M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7083m_box.jpg?v=1792646302"},{"product_id":"58-4-g-l-nacl-standard-solution-500-ml-hi7084l","title":"58.4 g\/L NaCl Standard Solution (500 mL) - HI7084L","description":"\u003cp\u003eHI7084L is a premium quality 58.4 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7084L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7084L 58.4 g\/L NaCl Standard Solution (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 58.4 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7084L\"\u003eHI7084L 58.4 g\/L NaCl Standard Solution (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871369986417,"sku":"HI7084L","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7084l_box.jpg?v=1792646302"},{"product_id":"0-3-g-l-nacl-standard-solution-500-ml-hi7085l","title":"0.3 g\/L NaCl Standard Solution (500 mL) - HI7085L","description":"\u003cp\u003eHI7085L is a premium quality 0.3 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7085L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI7085L 0.3 g\/L NaCl Standard Solution (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esodium chloride standard solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.3 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7085L\" target=\"_blank\" rel=\"noopener\"\u003eHI7085L 0.3 g\/L NaCl Standard Solution (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871370019185,"sku":"HI7085L","price":3002.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7085l_box_2.jpg?v=1792646304"},{"product_id":"5-84-g-l-nacl-standard-solution-500-ml-hi7088l","title":"5.84 g\/L NaCl Standard Solution (500 mL) - HI7088L","description":"\u003cp\u003eHI7088L is a premium quality 5.84 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7088L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7088L 5.84 g\/L NaCl Standard Solution (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 5.84 g\/L NaCl \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7088L\"\u003eHI7088L 5.84 g\/L NaCl Standard Solution (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871370051953,"sku":"HI7088L","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7088l_box.jpg?v=1792646304"},{"product_id":"125-g-l-nacl-standard-solution-500-ml-hi7089l","title":"125 g\/L NaCl Standard Solution (500 mL) - HI7089L","description":"\u003cp\u003eHI7089L is a premium quality 125 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7089L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI7089L 125 g\/L NaCl Standard Solution (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esodium chloride standard solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e125 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7089L\" target=\"_blank\" rel=\"noopener\"\u003eHI7089L 125 g\/L NaCl Standard Solution (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871371657585,"sku":"HI7089L","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7089l_box.jpg?v=1792646305"},{"product_id":"isa-solution-for-sodium-ise-500-ml-hi7090l","title":"ISA Solution for Sodium ISE (500 mL) - HI7090L","description":"\u003cp\u003eHI7090L is a premium quality ISA solution produced in accordance with ISO 3696\/BS3978 standards using high purity reagents,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI709-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Manganese High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI709-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Cuvettes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI709-11\"\u003eManganese High-Range Checker\u003csup\u003e®\u003c\/sup\u003e HC Calibration Check Set - HI709-11\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871384666481,"sku":"HI7090L","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7090l_box.jpg?v=1792646306"},{"product_id":"3-0-g-l-nacl-standard-solution-500-ml-hi7083l","title":"3.0 g\/L NaCl Standard Solution (500 mL) - HI7083L","description":"\u003cp\u003eHI7083L is a premium quality 3.0 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7083L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI7083L 3.0 g\/L NaCl Standard Solution (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esodium chloride standard solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e3.0 g\/L NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7083L\" target=\"_blank\" rel=\"noopener\"\u003eHI7083L 3.0 g\/L NaCl Standard Solution (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871384699249,"sku":"HI7083L","price":3002.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7083l_box.jpg?v=1792646306"},{"product_id":"2-3-g-l-sodium-standard-solution-500-ml-hi7080l","title":"2.3 g\/L Sodium Standard Solution,  500 mL - HI7080L","description":"\u003cp\u003eHI7080L is a premium quality 2.3 g\/L sodium standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts, deionized water, certified weight-checked balances, and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7080L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e2.3 g\/L Sodium Standard Solution, 500 mL - HI7080L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esodium standard solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e2.3 g\/L Na\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7080L\" target=\"_blank\" rel=\"noopener\"\u003e2.3 g\/L Sodium Standard Solution, 500 mL - HI7080L\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871386009969,"sku":"HI7080L","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7080l_box.jpg?v=1792646313"},{"product_id":"2-3-g-l-sodium-standard-solution-230-ml-hi7080m","title":"2.3 g\/L Sodium Standard Solution,  230 mL - HI7080M","description":"\u003cp\u003eHI7080M is a premium quality 2.3 g\/L sodium standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7080M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 2.3 g\/L Sodium Standard Solution, 230 mL - HI7080M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium standard solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eg\/L (ppt) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 2.3 g\/L Na\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7080M\"\u003e2.3 g\/L Sodium Standard Solution, 230 mL - HI7080M\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871386042737,"sku":"HI7080M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7080m_box.jpg?v=1792646313"},{"product_id":"30-g-l-nacl-standard-solution-230-ml-hi7081m","title":"30 g\/L NaCl Standard Solution (230 mL) - HI7081M","description":"\u003cp\u003eHI7081M is a premium quality 30 g\/L NaCl calibration standard solution produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7081M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7081M 30 g\/L NaCl Standard Solution (230 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e sodium chloride standard solution \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emg\/L (ppm) Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 30 mg\/L NaCl \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7081M\"\u003eHI7081M 30 g\/L NaCl Standard Solution (230 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871386075505,"sku":"HI7081M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7081m_box.jpg?v=1792646313"},{"product_id":"magnetic-stir-bars-10-medium-sized-hi731320","title":"Magnetic Stir Bars (10) Medium Sized - HI731320","description":"\u003cp\u003eThe HI731320 set of 10 magnetic stir bars made for a variety of applications. Used in a laboratory setting,  a magnetic stirrer together with magnetic stir bars continually stir buffers and\/or samples to keep them homogeneous. By keeping samples uniform during measurement and titration,  erroneous results are eliminated by preventing any temperature gradients or inadequate mixing when chemicals are added to a sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI731320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Magnetic Stir Bars (10) Medium Sized - HI731320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e L 50 mm x dia 7 mm\/ 2 in. x 0.3 in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eQuantity: 10\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI731320\"\u003eMagnetic Stir Bars (10) Medium Sized - HI731320\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871393415537,"sku":"HI731320","price":10619.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi731319_3.jpg?v=1792646363"},{"product_id":"digital-conductivity-probe-for-hi98199-10m-cable-hi763093","title":"Digital Conductivity Probe for HI98199, 10m cable - HI763093\/10","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/digital_electrode_thm.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Microchip\u003c\/h4\u003e\n\u003cp\u003eThe built-in microchip stores sensor type,  serial number and calibration information including date,  time,  and calibration points. This information is automatically retrieved by HI98199 once the probe is plugged in. The ability to transfer information allows for hot swapping of probes without recalibrating. All conductivity measurements are performed within the probe and transferred digitally to the meter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Four_ring_EC_probe.png\" alt=\" Four Ring Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFour Ring Technology\u003c\/h4\u003e\n\u003cp\u003eThe four ring,  also known as four pole,  technology allows the use of a single probe with solutions ranging from reverse osmosis to brine solution. The four ring technology is a potentiometic design that reduces polarization effects as compared with amperometric sensors.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI763093_Probe.png\" alt=\" ABS body with PVC sleeve \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eABS Body with PVC Sleeve\u003c\/h4\u003e\n\u003cp\u003eThe AISI 316 stainless steel rings are mounted to ABS plastic. The outer removable sleeve is made of PVC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Four_ring_EC_probe.png\" alt=\" Temperature Sensor \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eThe built-in temperature sensor provides for automatic temperature compensation of all conductivity readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/9819x-quickconnect.png\" alt=\" Quick Connect DIN Connector \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eWaterproof Quick Connect\u003c\/h4\u003e\n\u003cp\u003eThe HI763093 probe has a quick connect DIN connector that provides a for a secure waterproof connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI763093\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Digital Conductivity Probe for HI98199 - HI763093\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e ABS body, PVC sleeve and stainless steel rings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e quick connect DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e to only be used with HI98199 portable pH\/EC\/DO meter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI763093\"\u003eDigital Conductivity Probe for HI98199 - HI763093\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871405244785,"sku":"HI763093\/10","price":49080.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi763093_ec-probe-rings.jpg?v=1792646446"},{"product_id":"hi76310-ec-tds-probe-for-hi2300","title":"HI76310 EC\/TDS Probe for HI2300","description":"\u003cp\u003e“EC” stands for Electrical Conductivity. Electrical conductivity is defined as the ability of a substance to conduct an electrical current. Conductivity in a solution is directly proportional to the concentration of salts. Conductivity is temperature dependent and will rise in proportion to a temperature increase.\u003c\/p\u003e\n\u003cp\u003eEC is recorded in mS (milliSiemens) or µS (MicroSiemens).\u003c\/p\u003e\n\u003cp\u003e1 mS = 1000 µS\u003c\/p\u003e\n\u003cp\u003eTDS (Total Dissolved Solids) is a proportion of EC and is usually recorded in ppm (parts per million). Three common proportion multiplying factors are: 0.7 (hydroponics), 0.64 (soil science), and 0.5 are used to convert EC to TDS. For example, if the measured EC is 1000 µS, this can be converted by multiplying it by 0.7 (hydroponics) which equals 700 ppm.\u003c\/p\u003e\n\u003cp\u003eFour-ring conductivity probes utilize a potentiometric approach to measure EC. An alternating current is applied to the outer two “drive” electrodes to induce a current in the solution. The voltage is measured between the inner pair of electrodes in solution. The voltage is proportional the conductivity of the sample. This technology extends the linear range of measurement, and reduces polarization effects.\u003c\/p\u003e\n\u003cp\u003eThe four-rings in the HI76310 are made with platinum and the body of the electrode is made of Polyetherimide (PEI) plastic that is resistant to many harsh chemicals. The four-ring design allows for this probe to be used over a wide range of measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI76310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI76310 EC\/TDS Probe for HI2300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI7631016 EC\/TDS probe is supplied with probe and quality testing certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI76310\" target=\"_blank\" rel=\"noopener\"\u003eHI76310 EC\/TDS Probe for HI2300\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871405441393,"sku":"HI76310","price":42019.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi763100-720x720-4fc6d614-9d16-4aa9-ac53-985c155a3003.png?v=1792646447"},{"product_id":"hi763100-digital-ec-temperature-electrode","title":"HI763100 - Digital EC\/Temperature Electrode","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/digital_electrode_thm.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Microchip\u003c\/h4\u003e\n\u003cp\u003eThe built-in microchip stores sensor type,  serial number and calibration information including date,  time,  offset,  slope,  probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/763100-4rings.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003ePotentiometric Measuring System\u003c\/h4\u003e\n\u003cp\u003eThe four ring potentiometric measuring system allows measurement of a broad range of samples while minimizing the effects of polarization. The two outer rings apply and alternating voltage and induce a current loop in the solution,  while the two inner rings measure the voltage drop induced by the current loops. This allows for a range of readings from very high to very low without changing electrodes.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/763100_sleeve.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSleeve\u003c\/h4\u003e\n\u003cp\u003eThe probe is surrounded by a chemically resistant plastic sleeve to maintain control external interferences from the sample. It also allows the current loop to be generated in a controlled area.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/763100-temp-sensor.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eInternal Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eSince temperature is an important factor for measuring conductivity,  a built in temperature sensor on the probe is very helpful. There is no need for an external temperature probe,  so that measurements can be made easily. The coefficient used to correct for changes in temperature is β,  which is expressed as a percentage of reading per degree of Celsius.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDigital,  microprocessor based - no high impedance signal to the meter\u003c\/li\u003e\n\u003cli\u003ePotentiometric measuring system- suitable over a wide range of conductivities\u003c\/li\u003e\n\u003cli\u003eBuilt-in temperature sensor - no need for an additional temperature probe\u003c\/li\u003e\n\u003cli\u003e3.5mm digital plug – easy to plug in,  no alignment necessary\u003c\/li\u003e\n\u003cli\u003ePEI body – highly durable and well-suited for field applications\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI763100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI763100 - Digital EC\/Temperature Electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e EC: 0 to 200 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e Platinum\/4-ring\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e -5 to 100°C (23 to 212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 1 m (3.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Insulator: glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e\n\u003cbr\u003e \u003cbr\u003e\n\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Meters\u003c\/td\u003e\n\u003ctd\u003e edge multiparameter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI763100\"\u003eHI763100 - Digital EC\/Temperature Electrode\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871405474161,"sku":"HI763100","price":47967.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi763100-lineart.jpg?v=1792646447"},{"product_id":"edge-ec-benchtop-meter-hi2030","title":"edge® EC Benchtop Meter - HI2030-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eedge uses advanced digital electrodes that have a built-in microchip that stores calibration information which is automatically transferred to the meter when connected.\u003c\/p\u003e\n\u003ch5\u003eDigital Electrodes\u003c\/h5\u003e\n\u003cp\u003eedge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.\u003c\/p\u003e\n\u003ch5\u003eFour Ring Probe\u003c\/h5\u003e\n\u003cp\u003eThe HI2030 edge EC\/TDS\/Salinity meter is supplied with the HI763100 four ring platinum conductivity probe that has a built in temperature sensor for automatic temperature compensated measurements. The four ring technology allows for a wide range of measurement with a single probe as compared to amperometric two pole probes that have a limited range and can suffer from polarization effects. The HI763100 probe has a glass and PVDF body with a PEI (polyetherimide ) sleeve. Both materials have excellent resistance against many aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003e3.5 mm Probe Input\u003c\/h5\u003e\n\u003cp\u003ePlugging an electrode in has never been simpler, no alignments, no broken pins, just connect the 3.5 mm plug and get started.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.\u003c\/p\u003e\n\u003ch5\u003eWall Mount\u003c\/h5\u003e\n\u003cp\u003eUsing the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.\u003c\/p\u003e\n\u003ch5\u003eCradle and Electrode Holder\u003c\/h5\u003e\n\u003cp\u003eedge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimium viewing angle.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.\u003c\/p\u003e\n\u003ch5\u003eTwo USB Ports\u003c\/h5\u003e\n\u003cp\u003eedge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.\u003c\/p\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cp\u003eedge allows you to store up to 1000 log records of data. Data can be logged on demand (200 records), on stability (200 records), or at a predefined interval (600 records). The information stored include current reading, date, time and GLP data.\u003c\/p\u003e\n\u003ch5\u003eBasic Mode\u003c\/h5\u003e\n\u003cp\u003eedge offers both Basic and Standard Modes. In Basic Mode the edge as an EC meter reduces features to simplify operation. In Basic Mode the meter will only allow for automatic temperature compensation, auto ranging of readings, and automatic cell factor correction while calibrating. The temperature correction coefficient is fixed to 1.9% \/ oC and interval logging is not available. In Standard mode the user has options to change these features.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/45ms0xpvk5?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/8c55539d67ea1d24de589d4f7ab0d40faf95a394.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI2030-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e® Multiparameter EC\/TDS\/Salinity Meter - HI2030\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.00 to 16.00 pH, -2.000 to 16.000 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH, 0.001 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01pH, ±0.002 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to 3 points (5 points*) calibration, 5 standard (7 standard*) buffers available (1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45*) and 2 custom buffers*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic -5 to 100º C (23 to 212º F) (using integral temperature sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm, 3.00 to 29.99 µS\/cm, 30.0 to 299.9 µS\/cm, 300 to 2999 µS\/cm, 3.00 to 29.99 mS\/cm, 30.0 to 200.0 mS\/cm, up to 500.0 mS\/cm, absolute conductivity ‡\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm, 00.1 µS\/cm, 0.01 µS\/cm, 0.01 mS\/cm, 00.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e1 Cell Factor calibration; 6 standards available: 84, 1413 µS\/cm, 5.00, 12.88, 80.0, 111.8 mS\/cm, 1 point offset: 0.00 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 ppm (mg\/L), 15.0 to 149.9 ppm (mg\/L), 150. to 1499. ppm (mg\/L), 1.50 to 14.99 g\/L, 15.0 to 100.0 g\/L, up to 400.0 g\/L absolute TDS ‡ (with 0.80 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g\/L, 0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic -5 to 100 ºC (23 to 212 ºF); NoTC - can be selected to measure absolute conductivity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00% \/ ºC (for EC and TDS only). Default value is 1.90% \/ ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (default value is 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0% NaCl *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point with HI 7037L Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e2.00 to 42.00 PSU *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU,\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 80.0 g\/L *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003epolarographic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 ppm (mg\/L), 0.0 to 300.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L), 0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 0% (HI 7040) and 100% (water saturated air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 ºC (32.0 to 122 ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L 1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e-500 to 4,000 m (-1640 to 13120’) 100 m (328’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 ºC, -4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C, ±1.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e\n\u003ctd\u003eHI 763100 EC\/temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eManual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs\/lot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 micro USB port for charging and PC connectivity, 1 USB port for storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eBuilt-in rechargeable battery with up to 8 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7mm (8” x 5.5” x 0.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g (8.82 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI2030 EC kit includes: HI763100 Conductivity probe, 4 sachets of 1413 µS\/cm conductivity standard, 2 sachets of 5000 µS\/cm conductivity standard, 2 sachets of 12880 µS\/cm conductivity standard, 2 sachets general purpose rinse solution, USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, quality certificate and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI2030-01\" target=\"_blank\" rel=\"noopener\"\u003e® Multiparameter EC\/TDS\/Salinity Meter - HI2030\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871457149297,"sku":"HI2030-02","price":103018.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/edgestraight_2.png?v=1792646937"},{"product_id":"edge-dedicated-conductivity-tds-salinity-meter-hi2003-02","title":"edge® Dedicated Conductivity\/TDS\/Salinity Meter - HI2003-02","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI2003-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eedge® Dedicated Conductivity\/TDS\/Salinity Meter - HI2003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 μS\/cm, 30.0 to 299.9 μS\/cm, 300 to 2999 μS\/cm, 3.00 to 29.99 mS\/cm, 30.0 to 200.0 mS\/cm, up to 500.0 mS\/cm (absolute EC)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 μS\/cm, 0.1 μS\/cm, 1 μS\/cm, 0.01 mS\/cm, 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 μS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point offset calibration (0.00 μS\/cm in air), 1 point slope calibration in EC standard 84 μS\/cm, 1413 μS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm and 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 ppm (mg\/L), 15.0 to 149.9 ppm (mg\/L), 150 to 1499 ppm (mg\/L), 1.50 to 14.99 g\/L, 15.0 to 100.0 g\/L, up to 400.0 g\/L (absolute TDS)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g\/L, 0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic -5 to 100º C (23 to 212º F); NoTC - none absolute conductivity.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00% \/ ºC (for EC and TDS only). Default value is 1.90% \/ ºC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (default value is 0.50)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point with HI 7037L Standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e2.00 to 42.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 80.0 g\/L*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 ºC ; -4.0 to 248.0 °F**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ºC; 0.1 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 ºC; ±0.9 ºF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Probe\u003c\/td\u003e\n\u003ctd\u003eHI763100 EC\/temperature probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eManual Log on Demand (Max. 200 logs); Manual Log on Stability (Max. 200 logs); Interval Logging 100 lots, Max. 600 logs\/lot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 micro USB port for charging and PC connectivity, 1 USB port for storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eBuilt-in rechargeable battery with up to 8 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7mm (8” x 5.5” x 0.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g (8.82 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eedge®EC HI2003 includes: HI763100 Conductivity probe, 4 sachets of 1413 μS\/cm conductivity standard, 2 sachets of 5000 μS\/cm conductivity standard, 2 sachets of 12880 μS\/cm conductivity standard, 2 sachets general purpose rinse solution, benchtop docking station with electrode holder, wall-mount cradle, USB cable, 5 VDC power adapter, quality certificate and instruction manual.\u003cbr\u003e\nNotes: * Not available in basic mode\u003c\/p\u003e\n\u003cp\u003e** with temperature compensation function disabled\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98309\" target=\"_blank\" rel=\"noopener\"\u003eedge® Dedicated Conductivity\/TDS\/Salinity Meter - HI2003\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460196721,"sku":"HI2003-02","price":96194.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/edge-HI2003-Beaker-3772x3772-73eefe52-6c0d-40fc-9593-848d7ea47035-scaled.jpg?v=1792646964"}],"url":"https:\/\/hannainst.in\/collections\/parameter-salinity.oembed","provider":"hanna","version":"1.0","type":"link"}