{"title":"Titration","description":"","products":[{"product_id":"mini-titrator-for-measuring-titratable-acidity-in-wine-hi84502","title":"Mini-Titrator for Measuring Titratable Acidity in Wine - HI84502-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eAcids occur naturally as grapes grow and during the eventual fermentation process. Wines have lower levels of acid when there is a hot growing season or when the grapes come from warmer regions. In the proper proportion, acids are a desirable trait, giving the wine a distinct character. The three predominant acids in wine are tartaric, malic and citric. Tartaric acid is the principal acid in grapes and is a component that promotes a crisp flavor and graceful aging in wine. A moderate amount of a wine's acid comes from malic acid, which contributes to fruitiness. A small amount of titratable acidity comes from citric acid. Wine also contains trace amounts of other acids; the least desirable acid in wine is acetic acid, which, when present in more than a nominal amount, gives wine a sour or vinegary aspect.\u003c\/p\u003e\n\u003cp\u003eTotal acidity, also called titratable acidity, is the sum of the fixed and volatile acids. In the United States, the total acidity is usually expressed in terms of tartaric acid, even though other acids are also measured. Total acidity directly affects the color and flavor of wine and, depending on the style of the wine, is sought in a perfect balance with the sweet and bitter sensations of other components. Too much acidity makes wine tart and sharp; too little makes wines flat and uninteresting. Proper acidity in wine is what makes it refreshing and an ideal accompaniment to food. The proper acid level of a wine varies, with sweeter wines generally requiring somewhat higher levels to retain the proper balance.\u003c\/p\u003e\n\u003ch5\u003eApplication-Specific pH Electrode\u003c\/h5\u003e\n\u003cp\u003eThe HI84502 is supplied with the HI1048B glass body pH electrode featuring CPS™technology to prevent the clogging of the reference junction. Conventional electrodes may clog quickly in biological samples that have a high solids content such as wine must. By design, the HI1048B pH electrode utilizes a polytetrafluoroethylene (PTFE) sleeve junction which controls a steady, predictable flow of electrolyte solution, keeping the junction open. The hydrophobic properties of PTFE repel wetness and coatings.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84502 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 600 rpm, regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Help.jpg\" alt=\"titrator screenshot\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Interface\u003c\/strong\u003e The HI84502 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-Titration-Results.jpg\" alt=\"Titrate LR \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Titration-Curve.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGraphic Mode \u003c\/strong\u003e This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Log.jpg\" alt=\"mini titrator acidity logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eLog-on-Demand\u003c\/strong\u003e The HI84502 allows for data logging of up to 400 samples: 200 titration results and 200 pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-pH-Electrode-Condition.jpg\" alt=\"mini titrator pH mv meter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003e In addition to being an automatic titrator, the HI84502 also can be used as a pH\/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-CALCheck.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e Accuracy is always ensured with Hanna's unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty\/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84502 is used as a pH meter, but also an accurate titration since the endpoint of a total acidity titration is determined by a set pH value.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI84502-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMini-Titrator for Measuring Titratable Acidity in Wine - HI84502\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone, two, or three-point calibration, four available buffers (4.01, 7.01, 8.20, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003eacid base titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eendpoint titration: 7.00 pH or 8.20 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.1 to 5.0 g\/L of tartaric acid; High Range: 4.0 to 25.0 g\/L of tartaric acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 g\/L (ppt)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003e3% of reading or ±0.1 g\/L, whichever is greater (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003eLow Range: 10 mL; High Range: 2 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1048B glass body pH electrode with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eHI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer at 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84502 is supplied with HI1048B pH electrode, HI7662-T temperature probe, HI7082 electrode fill solution (30 mL), HI84502-50 (230 mL) titration solution, HI84502-55 pump calibration standard (120 mL), 100 mL beakers (2), dosing pump valve, 2000 µL automatic pipette with plastic tips (2), 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, cleaning solution sachets for wine deposits, cleaning solution sachets for wine stains (2), 12 VDC adapter and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI84502-01\" target=\"_blank\" rel=\"noopener\"\u003eMini-Titrator for Measuring Titratable Acidity in Wine - HI84502\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871179145585,"sku":"HI84502-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84502_1.jpg?v=1792645822"},{"product_id":"mini-titrator-for-measuring-titratable-alkalinity-in-water-and-wastewater-hi84531","title":"Mini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eAlkalinity is the ability of water to neutralize acids. Total titratable alkalinity is a measure of primarily three types of alkalinities present in a water sample: hydroxides, carbonates, and bicarbonates. Alkalinity in water can be the result of contributions from common chemicals including carbonates, bicarbonates, hydroxides, phosphates, borate and organic acid salts.\u003c\/p\u003e\n\u003cp\u003eThe alkalinity of a water sample indicates its ability to resist pH change. The amount of alkalinity in water is mostly due to the bicarbonate\/carbonate present. A low alkalinity level indicates that the water is susceptible to pH changes, while a high alkalinity level indicates that the water will be able to resist pH changes. Alkalinity can also be used to determine the corrosive capacity of water and can provide an estimation of water hardness.\u003c\/p\u003e\n\u003ch5\u003eDouble Junction pH Electrode\u003c\/h5\u003e\n\u003cp\u003eThe HI84531 is supplied with the HI1131B refillable, double junction, combination pH electrode. By design, the HI1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for direct measurements or acid base titrations in the water industry.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84531 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 600 rpm, regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Help.jpg\" alt=\"titrator screenshot\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Interface\u003c\/strong\u003eThe HI84531 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-Titration-Results.jpg\" alt=\"Titrate LR \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84531-TitrationCurve_400x201_1.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGraphic Mode \u003c\/strong\u003e This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Log.jpg\" alt=\"mini titrator acidity logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eLog-on-Demand\u003c\/strong\u003eThe HI84531 allows for data logging of up to 400 samples: 200 titration results and 200 pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-pH-Electrode-Condition.jpg\" alt=\"mini titrator pH mv meter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003e In addition to being an automatic titrator, the HI84531 also can be used as a pH\/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-CALCheck.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003eAccuracy is always ensured with Hanna's unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty\/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84531 is used as a pH meter, but also an accurate titration since the endpoint of a titratable alkalinity titration is determined by a set pH value.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI84531-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone, two or three-point calibration; four available buffers (4.01, 7.01, 8.30, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003eacid-base titration (strong alkalinity\/total alkalinity)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eendpoint titration: 8.30 pH (phenolphthalein) \/ 4.50 pH (bromcresol green-methyl red)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 30.0 to 400.0 mg\/L; 0.6 to 8.0 meq\/L\nHigh Range: 300 to 4000 mg\/L; 6.0 to 80.0 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.1 mg\/L (ppm); 0.1 meq\/L; High Range: 1 mg\/L (ppm); 0.1 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±1 mg\/L or 3% of reading, whichever is greater\nHigh Range: ±10 mg\/L or 3% of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003eLow Range: 50 mL; High Range: 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eHI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer at 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84531 is supplied with HI1131B pH electrode, HI7662-M temperature probe, HI84531-50 low range titrant (120 mL), HI84531-51 high range titrant (120 mL), HI84531-55 calibration standard (230 mL), 100 mL beakers (2), dosing pump valve, 5 mL syringe, 2000 µL automatic pipette with two plastic tips, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, power adapter, instruction manual and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI84531-01\" target=\"_blank\" rel=\"noopener\"\u003eMini Titrator for Measuring Titratable Alkalinity in Water and Wastewater - HI84531\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871244550513,"sku":"HI84531-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84531_1.jpg?v=1792645926"},{"product_id":"mini-titrator-for-measuring-titratable-acidity-in-fruit-juice-hi84532","title":"Mini Titrator for Measuring Titratable Acidity in Fruit Juice - HI84532-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eTitratable acidity is an important parameter in determining fruit maturity and sour taste in citrus fruits. The maturity of fruit is one of the most important factors to determine how well fruit will store and how it will taste. For some fruits, governmental quality standards (based on titratable acidity or the ratio of total soluble solids (°Brix) to titratable acidity) are in place to protect consumers. Immature fruit will normally have a low sugar to acid ratio as compared to mature fruit that will have a high sugar to acid ratio.\u003c\/p\u003e\n\u003cp\u003eThe HI84532 measures the concentration of titratable hydrogen ions contained in fruit juice samples by neutralization with a strong base solution to a fixed pH. This value includes all the substances of an acidic nature in the fruit juice including: free hydrogen ions, organic acids and acid salts. Titratable acidity is expressed as g\/100 mL of the predominant acid. The predominant acids in fruit depend on the type of fruit being tested and include citric acid, tartaric acid, and malic acid.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/juice-acid-types.jpg\" alt=\"juice acid types and titratable acidity\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003e\u003cstrong\u003eDouble Junction pH Electrode\u003c\/strong\u003e\u003c\/h5\u003e\n\u003cp\u003eThe HI84532 is supplied with the HI1131B refillable, double junction, combination pH electrode. By design, the HI1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for direct measurements or titrations in the beverage industry.\u003c\/p\u003e\n\u003ch5\u003eCustom pH Calibration\u003c\/h5\u003e\n\u003cp\u003eAccording to AOAC International the titration endpoint for fruit products is pH 8.1. The HI84532 uses a custom calibration point of pH 8.20. The preprogrammed pH 4.01 and pH 8.20 calibration points allows for calibration of the meter that brackets the pH readings.\u003c\/p\u003e\n\u003ch5\u003eGood Laboratory Practice\u003c\/h5\u003e\n\u003cp\u003eThe HI84532 offers comprehensive GLP information including date and time of the last pH electrode and dosing pump calibrations. Tracking calibrations are critical to have confidence in the results obtained from titrations. The GLP data is stored along with any logged readings.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84532 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. This titrant is dynamically dosed, where titrant is delivered in larger doses at the start of the titration and smaller doses near the end point. With larger doses in the beginning of the titration, the speed of the titration is increased, where smaller doses near the end point allow for more time for the titrant and analyte to react. Smaller doses also prevent the over titration of a sample and a more accurate determination of titrant volume used.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 600 rpm, regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Help.jpg\" alt=\"titrator screenshot\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Interface\u003c\/strong\u003eThe HI84532 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84500-Procedure-Warnings.jpg\" alt=\"warning\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Titration-Curve.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGraphic Mode \u003c\/strong\u003e This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Log-Recall.jpg\" alt=\"mini titrator acidity logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eLog-on-Demand\u003c\/h5\u003e\n\u003cp\u003eThe HI84532 allows for data logging of up to 400 samples: 200 titration results and 200 pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-pH-Electrode-Condition.jpg\" alt=\"mini titrator pH mv meter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003e In addition to being an automatic titrator, the HI84532 also can be used as a pH\/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-CALCheck.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e Accuracy is always ensured with Hanna's unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty\/Broken, and overall probe condition. The CAL Checkfunction not only ensures an accurate pH reading when the HI84532 is used as a pH meter, but also an accurate titration since the endpoint of a titratable acidity titration is determined by a set pH value.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI84532-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMini Titrator for Measuring Titratable Acidity in Fruit Juice - HI84532\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone, two, or three-point calibration, four available buffers (4.01, 7.01, 8.20, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003eacid base titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eendpoint titration: 8.1 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003eLow Range (g\/100 mL): citric acid: 0.10 to 2.00% CA; tartaric acid: 0.11 to 2.35% TA; malic acid: 0.10 to 2.09% MA\nHigh Range (g\/100 mL): citric acid: 1.00 to 10.00% CA; tartaric acid: 1.17 to 11.72% TA; malic acid: 1.05 to 10.47% MA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02% or 3% of reading CA whichever is greater (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003eLow Range: 5 mL High Range: 5 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eHI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer at 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84532 is supplied with HI1131B pH electrode, HI84532-50 low range titrant (100 mL), HI84532-51 high range titrant (100 mL), HI84532-55 calibration standard (100 mL), HI7662-T temperature probe, HI7082 electrode fill solution (30 mL), 100 mL beakers (2), 20 mL beaker, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, stir bar, power adapter, instruction manual and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI84532-02\" target=\"_blank\" rel=\"noopener\"\u003eMini Titrator for Measuring Titratable Acidity in Fruit Juice - HI84532\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871341085041,"sku":"HI84532-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84532_mini-angle_1.jpg?v=1792646194"},{"product_id":"mini-titrator-for-measuring-titratable-acidity-in-dairy-products-hi84529","title":"Mini Titrator for Measuring Titratable Acidity in Dairy Products - HI84529-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThe HI84529 uses methods based on AOAC International and Standard Methods for the Examination of Dairy Products. Both of these methods report titratable acidity as % lactic acid and a conversion factor is used to convert the results to the other available units. The HI84529 can be customized to meet the needs of any dairy analysis lab. Samples can be titrated by weight or volume, diluted or non-diluted (low range only) and titrated to a fixed pH endpoint that can be adjusted by the user. The HI84529 offers three different methods depending on the expected range and the weight of sample used. Select low range 50 to titrate a 50 mL or 50 g undiluted sample. The other titration options are low range 20 and high range 20 to titrate 20 mL or 20 g samples that are diluted twice their volume with deionized or distilled water.\u003c\/p\u003e\n\u003cp\u003eThere are two fundamentally different measurements of dairy products: titratable acidity and pH. pH is a measurement of hydrogen ion concentration while titratable acidity is the neutralizing capacity of a dairy product with NaOH. An increase in acidity can be caused by bacteria formation. Monitoring acidity is a way of determining the quality and freshness of dairy products. Acidity is determined by a pH endpoint titration using NaOH (sodium hydroxide), and is defined as the consumption necessary to shift the pH value from 6.6 (corresponding to fresh milk) to a pre-determined pH value. When using phenolphthalein as an indicator, a faint pink color change occurs at pH 8.3.\u003c\/p\u003e\n\u003cp\u003eTitratable acidity is expressed in a variety of units based on the titration method performed. Each method varies in sample size and strength of NaOH used for the titration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e% Lactic Acid (%l.a.)\u003c\/strong\u003e: Determined by taking a 20 mL or 20 g sample and diluting with twice its volume with deionized or distilled water. The sample is then titrated with 0.1 M NaOH to a phenolphthalein endpoint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDegree Soxhlet Henkel (°SH)\u003c\/strong\u003e: Determined by titrating a 50 mL sample with 0.1 M NaOH to a phenolphthalein endpoint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDegree Dornic (°D)\u003c\/strong\u003e: Determined by titrating a 100 mL sample with N\/9 NaOH to a phenolphthalein endpoint.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDegree Thörner\u003c\/strong\u003e: Determined by taking a 10 mL sample and diluting with twice its volume with deionized or distilled water. The sample is then titrated with 0.1 M NaOH to a phenolphthalein endpoint.\u003c\/p\u003e\n\u003cp\u003eKnowing the relationship between sample weight or volume and strength of titrant it is possible to convert the reading obtained from one method to another. Below is a table with the factors preprogrammed in the HI84529 for converting between various units of measure.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"83\"\u003e \u003ccol width=\"89\"\u003e \u003ccol width=\"92\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eFrom:\u003c\/td\u003e\n\u003ctd\u003eTo:\u003c\/td\u003e\n\u003ctd\u003eDivide By:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e%l.a.\u003c\/td\u003e\n\u003ctd\u003e°SH\u003c\/td\u003e\n\u003ctd\u003e0.0225\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e%l.a.\u003c\/td\u003e\n\u003ctd\u003e°D\u003c\/td\u003e\n\u003ctd\u003e0.0100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e%l.a.\u003c\/td\u003e\n\u003ctd\u003e°Th\u003c\/td\u003e\n\u003ctd\u003e0.0090\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eTable for converting % lactic acid (%l.a.) to Degree Soxhlet Henkel (°SH), Degree Dornic (°D), and Degree Thorner °Th.\u003c\/p\u003e\n\u003ch5\u003eApplication-Specific Half-Cell pH Electrode\u003c\/h5\u003e\n\u003cp\u003eThe HI84529 is supplied with the FC260B half-cell glass body pH electrode. A pH half-cell electrode consist only of the pH indicating electrode. There is no reference cell with a junction. The FC260B half-cell electrode uses low temperature (LT) glass with a spherical bulb and glass body. This design consideration is ideal for direct pH measurement or titration of dairy related products.\u003c\/p\u003e\n\u003ch5\u003eLow Temperature Glass Formulation\u003c\/h5\u003e\n\u003cp\u003eThe glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many dairy products are stored at low temperatures. As the temperature of the glass decreases in the sample, the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass, the resistance would increase above the optimum resistance for the high impedance input of a pH meter. The FC260B is suitable to use with samples that measure from -5 to 100℃.\u003c\/p\u003e\n\u003ch5\u003eReference Half-Cell\u003c\/h5\u003e\n\u003cp\u003eMost pH electrodes are combination pH electrodes in which both half cells are supplied in a single probe design. The reference cell of these electrodes typically have a junction made of ceramic, glass, or PTFE. The junction of a reference electrode provides the electrical pathway between the inner portion of the electrode and the sample The HI84529 is supplied with the HI5315 reference half-cell. The HI5315 has a skirted cone junction that allows for an extremely stable reference voltage with the sample. The HI5315 features a plunger design that can be used to flush any solids that have accumulated at the junction surface. The HI5315 can also be completely disassembled for cleaning. The ability to maintain a clean open junction allows for repeatable and accurate measurement.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84529 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.\u003c\/p\u003e\n\u003ch5\u003eCustom pH Calibration\u003c\/h5\u003e\n\u003cp\u003eAccording to AOAC International and Standard Methods for the Examination of Dairy Products the titration endpoint for % lactic acid is pH 8.3. The HI84529 uses custom calibration points based on the pH of fresh milk and the titration endpoint. The preprogrammed pH 6.00 and pH 8.30 calibration points allows for calibration of the meter that brackets the pH readings.\u003c\/p\u003e\n\u003ch5\u003eGood Laboratory Practice\u003c\/h5\u003e\n\u003cp\u003eThe HI84529 offers comprehensive GLP information including date and time of the last pH electrode and dosing pump calibrations. Tracking calibrations are critical to have confidence in the results obtained from titrations. The GLP data is stored along with any logged readings.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 800 rpm for low range titrations and 1000 rpm for high range titrations, regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Help.jpg\" alt=\"titrator screenshot\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Interface\u003c\/strong\u003eThe HI84529 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-Titration-Results.jpg\" alt=\"Titrate LR \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Titration-Curve.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eGraphic Mode \u003c\/strong\u003e This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Log.jpg\" alt=\"mini titrator acidity logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eLog-on-Demand\u003c\/strong\u003eThe HI84529 allows for data logging of up to 400 samples: 200 titration results and 200 pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-pH-Electrode-Condition.jpg\" alt=\"mini titrator pH mv meter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003eIn addition to being an automatic titrator, the HI84529 also can be used as a pH\/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84529-cal.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eCAL Check\u003csup\u003e™\u003c\/sup\u003e\u003c\/strong\u003e Accuracy is always ensured with Hanna's unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty\/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84529 is used as a pH meter, but also an accurate titration since the endpoint of a titratible acidity titration is determined by a set pH value.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI84529-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMini Titrator for Measuring Titratable Acidity in Dairy Products - HI84529\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone, two or three-point calibration; four available buffers (4.01, 6.00, 8.30, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003eacid base titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eendpoint titration, adjustable (pH 8.0 - 8.7 in 0.1 increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: %l.a.: 0.01 to 0.20; °SH: 0.4 to 8.9; °D: 1.0 to 20.0; °Th: 1.1 to 22.2\nHigh Range: %l.a.: 0.1 to 2.0; °SH: 4.4 to 88.9; °D: 10 to 200; °Th: 11.1 to 222.2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range: %I.a.: 0.01 ; °SH: 0.1; °D: 0.1; °Th: 0.1 High Range: %I.a.: 0.1; °SH: 0.1; °D: 1; °Th: 0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ± 0.01 %l.a. High Range: ± 0.1 %l.a. (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003eLR 20: 20 mL or 20 g LR 50: 50 mL or 50 g HR 20: 20 mL or 20 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eFC260B pH electrode with 1 m (3.3’) cable (included), HI5315 reference electrode with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eHI7662-M temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer at 800 rpm (Low Range) \/ 1000 rpm (High Range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84529-01 is supplied with FC260B pH electrode, HI5315 reference electrode, HI7662-M temperature probe, HI84529-50 low range 20 titrant (120 mL), HI84529-52 low range 50 titrant (120 mL), HI84529-51 high range 20 titrant (120 mL), HI84529-55 calibration standard (230 mL), HI7072 fill solution (30 mL), HI700640 cleaning solution for milk deposits (2 x 20 mL), capillary dropper pipette, 100 mL beakers (2), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, 12VDC power adapter, instruction manual and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI84529-01\" target=\"_blank\" rel=\"noopener\"\u003eMini Titrator for Measuring Titratable Acidity in Dairy Products - HI84529\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871341183345,"sku":"HI84529-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84529_mini-angle.jpg?v=1792646196"},{"product_id":"dual-platinum-pin-electrode-for-hi933-hi76320","title":"Dual Platinum Pin Electrode for HI933 - HI76320","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI76320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Dual Platinum Pin Electrode for HI903 - HI76320\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI76320\"\u003eDual Platinum Pin Electrode for HI903 - HI76320\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871405703537,"sku":"HI76320","price":43677.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi76320.jpg?v=1792646450"},{"product_id":"mini-titrator-for-measuring-titratable-acidity-in-water-hi84530","title":"Mini Titrator  for Measuring Titratable Acidity in Water - HI84530-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eAcidity is an important parameter used to determine the quality of water (surface,  drinking,  wastewater). Acidity affects many things including chemical reaction rates,  biological processes,  and corrosiveness. It can also be used to monitor pollution in wastewater and drinking water.\u003c\/p\u003e\n\u003cp\u003eTotal titratable acidity is a quantitative measurement of the water sample's ability to react with a strong base solution to a specific pH value. Many chemical species can contribute to the acidity measurement depending on the method of analysis. These species can include strong acids (hydrochloric acid,  nitric acid,  sulfuric acid,  etc.),  weak acids (acetic acid,  carbonic acid,  etc.),  and hydrolyzing salts (iron,  aluminum,  manganese,  etc.)\u003c\/p\u003e\n\u003ch5\u003eDouble Junction pH Electrode\u003c\/h5\u003e\n\u003cp\u003eThe HI84530 is supplied with the HI1131B refillable,  double junction,  combination pH electrode. By design,  the HI1131B has a spherical tip for use in aqueous or liquid solutions. This versatile electrode provides a wide surface of contact with a sample and is ideal for direct measurements or acid base titrations in the water industry.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84530 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 600 rpm,  regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84532-Help.jpg\" alt=\"titrator screenshot\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eTutorial and Help Screens\u003c\/strong\u003eThe HI84530 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built in tutorial mode that,  when enabled,  will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-Titration-Results.jpg\" alt=\"Titrate LR \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Titration-Curve.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eTitration Curve Displayed on Screen\u003c\/strong\u003eThis mini titrator displays in-depth data during titration,  including a real-time graph of the titration curve.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84502-Log.jpg\" alt=\"mini titrator acidity logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eLog and Recall Data\u003c\/strong\u003eThe HI84530 allows for data logging of up to 400 samples: 200 titration results and 200  pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI84530-pH-Electrode-Condition.jpg\" alt=\"mini titrator pH mv meter\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003eIn addition to being an automatic titrator,  the HI84530 also can be used as a pH\/mV meter. As a pH meter,  it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers,  a 0.01 pH resolution,  accuracy of ±0.01 pH,  automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84529-cal.jpg\" alt=\"mini titrator acidity graphic mode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e Accuracy is always ensured with Hanna's unique CAL Check feature,  which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer,  indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated,  Electrode Dirty\/Broken,  and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84530 is used as a pH meter,  but also an accurate titration since the endpoint of a titratible acidity titration is determined by a set pH value.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI84530-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Mini Titrator  for Measuring Titratable Acidity in Water - HI84530\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e -2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±1.0 mV (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e -2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e one, two or three-point calibration; four available buffers (4.01, 7.01, 8.30, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e manual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003e acid base titration, total acidity \/ strong acidity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003e fixed endpoint titration: 8.30 pH (phenolphthalein) or 3.7 pH (methyl orange)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003e Low Range (as CaCO₃): 15.0 to 400.0 mg\/L; 0.3 to 8.0 meq\/L  \u003cbr\u003e High Range (as CaCO₃): 300 to 4000 mg\/L; 6.0 to 80.0 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003e Low Range: 0.1 mg\/L \/ 0.1 meq\/L; High Range: 1 mg\/L \/ 0.1 meq\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003e Low Range: ±0.5 mg\/L or 3% of reading, whichever is greater (@25ºC\/77ºF) \u003cbr\u003e High Range: ±15 mg\/L or 3% of reading, whichever is greater (@25ºC\/77ºF) \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003e Low Range: 50 mL; High Range: 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e 10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e HI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e HI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e Log-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e up to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e 1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003e Built-in magnetic stirrer at 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84530 is supplied with the HI1131B pH electrode, HI7662-T temperature probe, HI84530-50 low range titrant, HI84530-51 high range titrant, HI84530-55 calibration standard, HI84530-60 hydrogen peroxide, 100 mL beakers (2), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), stir bar, power adapter, instruction manual and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI84530-01\"\u003eMini Titrator for Measuring Titratable Acidity in Water - HI84530\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871416648049,"sku":"HI84530-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84530_1.jpg?v=1792646566"},{"product_id":"automatic-potentiometric-titrator-hi931","title":"Automatic Potentiometric Titrator - HI931-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eSuperior design for the busy lab.\u003c\/h4\u003e\n\u003cp\u003eThe Cycoloy® body is durable, heat-resistant, and resists staining. Dedicated menu buttons are part of the control panel making it fully sealed and easy to clean. A high contrast LCD display makes every character on the display stand out and the wide viewing angle allows measurements to be seen from any angle. The backlight is adjustable for your viewing preference and with a backlight saver option protects the display during periods of inactivity.\u003c\/p\u003e\n\u003ch4\u003eMaximize your workspace.\u003c\/h4\u003e\n\u003cp\u003eThis new generation of titrator features a 50% smaller footprint than the HI901 Automatic Titrator for maximum use of your benchtop lab space.\u003c\/p\u003e\n\u003ch4\u003eIntuitive User Interface\u003c\/h4\u003e\n\u003cp\u003eFunctional keys on the control panel that correspond to virtual keys on the display allow for simple and quick navigation between screens and menu. If you need additional information about a screen, simply press the dedicated button for help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Titration_screens.jpg\" alt=\"Titration Screens\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMultiple Titration Types\u003c\/h4\u003e\n\u003cp\u003ePaired with the right electrode, this potentiometric titrator can perform any number of standard titrations including pH and mV tests with fixed endpoints or single equivalence points.\u003c\/p\u003e\n\u003ch4\u003eReal-Time Graphing\u003c\/h4\u003e\n\u003cp\u003eA real-time titration curve can be viewed as the titration progresses. This feature is useful when new methods are tested or when a procedure requires optimization.\u003c\/p\u003e\n\u003ch4\u003ePassword Protection\u003c\/h4\u003e\n\u003cp\u003eAdministrative users can set a PIN code on the device protecting against unauthorized access. Titration method options and results are tamper-proof while a non-administrator operates the titrator, ensuring records remain safe, secure, and traceable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932_Burrette-Removal-Hand.jpg\" alt=\"Clip-Lock™ burette \" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eExchangeable Burette System\u003c\/h4\u003e\n\u003cp\u003eWith Hanna’s Clip-Lock™ burette feature, it only takes a few seconds to exchange titrants and reagents preventing cross-contamination and saving time.\u003c\/p\u003e\n\u003ch4\u003ePrecision Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eOur unmatched 40, 000-step piston driven pump is capable of dosing extremely small and highly accurate volumes of titrant or reagent.\u003c\/p\u003e\n\u003ch4\u003eChemically Resistant Tubing\u003c\/h4\u003e\n\u003cp\u003eAspiration and dispensing tubes are constructed of chemically resistant PTFE plastic and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932_Holder-with-Probes.jpg\" alt=\"Flexible Electrode Holder\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFlexible Electrode Holder\u003c\/h4\u003e\n\u003cp\u003eThis electrode holder can hold up to 3 electrodes, 4 tubes, and 1 temperature probe. The holder is angled to concentrate the probes to the center for smaller beaker sizes. Use electrodes with different diameters when needed by changing the electrode guide.\u003c\/p\u003e\n\u003ch4\u003eAdjustable Arm\u003c\/h4\u003e\n\u003cp\u003eFor a more compact design, the electrode holder is built directly into the titrator body. Height control adjustments are performed by simply pressing the press-to-release button makes. The electrode holder is reversible for use with large magnetic stirrers or oversize beakers.\u003c\/p\u003e\n\u003ch4\u003ePrecision Stirring\u003c\/h4\u003e\n\u003cp\u003eThe removable overhead stirrer has built-in speed control for instant feedback in order to maintain consistent stirring speed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931_back.jpg\" alt=\"HI931 Back\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMultiple Measuring Modes\u003c\/h4\u003e\n\u003cp\u003eHI931 functions as a potentiometric titrator, pH meter, mV\/ORP meter, or ISE meter. Valuable laboratory bench space is saved, and multiple tests can be performed on one sample.\u003c\/p\u003e\n\u003ch4\u003eAnalytical Balance Interface\u003c\/h4\u003e\n\u003cp\u003eAnalytical balances with RS232 output can transfer the weight of a sample directly into the meter.\u003c\/p\u003e\n\u003ch4\u003ePrinter Interface\u003c\/h4\u003e\n\u003cp\u003eTitration reports can be printed directly from the titrator to a connected printer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI93X-baxk-pump-1200.jpg\" alt=\"Peristaltic Pump\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic Reagent Addition\u003c\/h4\u003e\n\u003cp\u003eA peristaltic pump may be programmed to volumetrically dispense reagent prior to titration or direct measurement. This helps achieve consistent and accurate results and prevents operator errors such as incorrect volumes or forgetting reagent addition. The peristaltic pump can also be used to aspirate post-analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI93X-inside.jpg\" alt=\"Well and Gutters\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSmart Design for Safety\u003c\/h4\u003e\n\u003cp\u003eIn the event of reagent leakage an external gutter system protects the connections on the back of the meter and interior prevent any liquids from the internal electronics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI93X_USB.jpg\" alt=\"USB Storage\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCustomizable Analysis Reports\u003c\/h4\u003e\n\u003cp\u003eEach analysis report is fully customizable so users can ensure they are storing and filing the best data required for their application. New multi-select feature makes batch processing simple.\u003c\/p\u003e\n\u003ch4\u003eFlexible GLP Management\u003c\/h4\u003e\n\u003cp\u003eAll necessary GLP (Good Laboratory Practice) information is recorded with each sample including sample identification, company and operator name, date, time, electrode ID codes, and calibration information.\u003c\/p\u003e\n\u003ch4\u003eUSB Data Transfer\u003c\/h4\u003e\n\u003cp\u003eA conveniently located USB port on the side of the meter is used with a flash drive or direct connection to a PC for the transfer of titration methods, reports, and software upgrades. Reports can be converted to a LIMS friendly format with the use of our PC compatible software.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI932-Right-Front-Raised.jpg\" alt=\"HI932 Advanced Automatic Potentiometric Titrator\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eNeed more?\u003c\/h4\u003e\n\u003ch4\u003eUpgrade to the HI932 Advanced Automatic Potentiometric Titrator for Multiple Sensor Inputs\u003c\/h4\u003e\n\u003ch4\u003eHI932 - Advanced Automatic Potentiometric Titrator\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI931001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003epH and mV precision simulator with LCD - HI931001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e±0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAll output values simulated at 25°C (77°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e-1000 to 1000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e9V \/ approximately 100 hours of use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e180 x 83 x 40 mm (7.1 x 3.3 x 1.6 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e255 g (9.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI931001 is supplied with HI7858\/1 BNC\/BNC coaxial cable.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI931001\" target=\"_blank\" rel=\"noopener\"\u003epH and mV precision simulator with LCD - HI931001\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871419761009,"sku":"HI931-02","price":754110.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-Angle-Low-Front-GLASS-5249x5249-f3f872c0-f0ca-4859-ad40-62f52e362e74.jpg?v=1792646608"},{"product_id":"karl-fischer-volumetric-titrator-hi933","title":"Karl Fischer Volumetric Titrator HI933-02","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI903-angle.jpg\" alt=\"HI903 Angled\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eTitrator Capabilities\u003c\/h5\u003e\n\u003ch4\u003eDynamic Titrant Dosing\u003c\/h4\u003e\n\u003cp\u003eThe dynamic dosing feature allows for timely and accurate titration results by relating the titrant volume dosed to the mV response from the titration reaction. This provides for larger doses near the beginning of a titration and smaller, more precise doses near the titration endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eDrift Rate Compensation\u003c\/h4\u003e\n\u003cp\u003eThe HI903 automatically adjusts the titration calculation to account for the effects of any ambient humidity entering the titration cell. This provides a more accurate result by correcting for water not present in the actual sample.\u003c\/p\u003e\n\u003ch4\u003eTitration Results Averaging\u003c\/h4\u003e\n\u003cp\u003eSuccessive results from a titration method may be averaged with recording of the standard deviation.\u003c\/p\u003e\n\u003ch4\u003eTitrant Recordkeeping\u003c\/h4\u003e\n\u003cp\u003eThe HI903’s titrant database can store information for up to 20 titrants. The database may be programmed to remind a user when to standardize their titrant, reducing error in analysis.\u003c\/p\u003e\n\u003ch4\u003eSelectable Endpoint Criteria\u003c\/h4\u003e\n\u003cp\u003eThe HI903 employs a dual platinum pin electrode for bivoltammetric endpoint determination. Users may choose termination criteria based on mV stability times or drift rates.\u003c\/p\u003e\n\u003ch4\u003eMultistage Cell Preparation\u003c\/h4\u003e\n\u003cp\u003eA pre-titration stage eliminates residual water present in the solvent and the cell, providing a reliable baseline start to analysis. Standby mode then keeps the solvent dry between titrations and when the titrator is not in use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI903_BuretteAndDosing.jpg\" alt=\"Burette and Dosing\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eBurettes \u0026amp; Dosing System\u003c\/h5\u003e\n\u003ch4\u003ePrecision Dosing Pump\u003c\/h4\u003e\n\u003cp\u003eOur unmatched 40, 000 step piston driven pump is capable of delivering as little as 0.125 µL of titrant accurately and precisely.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eChemically Resistant Tubing \u0026amp; Syringe\u003c\/h4\u003e\n\u003cp\u003eAspiration and dispensing tubes are constructed of durable, chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light sensitive reagents.\u003c\/p\u003e\n\u003ch4\u003eAnti-Diffusion Dispensing Tip\u003c\/h4\u003e\n\u003cp\u003eA specially designed glass dispensing tip delivers titrant precisely into high turbulence mixing zones, ensuring a rapid reaction. Its angular construction helps prevent titrant from diffusing into the sample solvent.\u003c\/p\u003e\n\u003ch5\u003eTitration \u0026amp; Solvent System\u003c\/h5\u003e\n\u003ch4\u003eEfficient Sample Handling\u003c\/h4\u003e\n\u003cp\u003eThe HI903 features a quick-remove sample port with a replaceable rubber septum allowing for fast and easy sample introduction to the titration vessel. An integrated magnetic stirrer ensures homogeneity for an accurate and speedy reaction.\u003c\/p\u003e\n\u003ch4\u003eChemically Resistant Titration Vessel\u003c\/h4\u003e\n\u003cp\u003eThe glass and PTFE titration cell and fittings are designed to withstand the harsh solvents and reagents involved in Karl Fischer reactions.\u003c\/p\u003e\n\u003ch4\u003eSealed Solvent System\u003c\/h4\u003e\n\u003cp\u003eThe titration vessel is completely sealed to minimize exposure to ambient humidity, keep the system dry, and reduce titrant consumption while saving time between titrations. Solvent may be exchanged in a matter of seconds without opening the titration vessel.\u003c\/p\u003e\n\u003ch4\u003eVisually Recognizable Desiccant\u003c\/h4\u003e\n\u003cp\u003eA rechargeable, color-indicating, silica gel desiccant prevents the ingress of ambient humidity into the sealed system while maintaining full titrator functionality. The desiccant color change allows a user to recognize when it’s adsorption capacity has depleted and is ready for replacement or recharging.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI903_TitrationSolventSystem.jpg\" alt=\"Titrant and Solvent System\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screenshots-Array_HI903.jpg\" alt=\"\" width=\"1200\" height=\"574\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eInterface \u0026amp; Display\u003c\/h5\u003e\n\u003ch4\u003eInteractive Color Display\u003c\/h4\u003e\n\u003cp\u003eA large, color LCD screen clearly shows the chosen titration method along with results, units, dosing size, titration volume, drift rate, and mV value.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eDetailed Titration Graphs\u003c\/h4\u003e\n\u003cp\u003eA real-time titration curve can be displayed during each titration; this feature is useful when new methods are tested or when a procedure requires optimization.\u003c\/p\u003e\n\u003ch4\u003eSimple \u0026amp; Quick Navigation\u003c\/h4\u003e\n\u003cp\u003eVirtual key selections present on the display allow for simple and quick navigation between screens and menus without getting lost in a nest of information.\u003c\/p\u003e\n\u003ch5\u003eData \u0026amp; Storage\u003c\/h5\u003e\n\u003ch4\u003eCustomizable Titration Reports\u003c\/h4\u003e\n\u003cp\u003eEach titration report is fully customizable so users can ensure they are storing and filing the appropriate data required for their application and procedures.\u003c\/p\u003e\n\u003ch4\u003eFlexible GLP Management\u003c\/h4\u003e\n\u003cp\u003eAll necessary GLP (Good Laboratory Practice) information can be recorded with each sample including: sample identification, company and operator name, date, time, and electrode ID codes.\u003c\/p\u003e\n\u003ch4\u003eEffortless Data Transfer\u003c\/h4\u003e\n\u003cp\u003eData can easily be transferred to a USB flash drive or PC with the Hanna HI900PC application software. The USB port allows for the transfer of titration methods, titration reports, and software upgrades via USB flash drive.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/USB-Key-copy.jpg\" alt=\"USB Transfer\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eConnectivity \u0026amp; Functionality\u003c\/h5\u003e\n\u003ch4\u003eConfigurable Balance Interface\u003c\/h4\u003e\n\u003cp\u003eSample size may be automatically entered from any laboratory analytical balance with a RS232 serial output saving time and labor.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMultiple Peripherals\u003c\/h4\u003e\n\u003cp\u003eUsers can print reports directly from the titrator using a standard parallel printer. An external monitor and keyboard may be attached for added versatility, as well as an analytical balance for automatic sample mass entry for titrations.\u003c\/p\u003e\n\u003ch5\u003eMethods of Analysis\u003c\/h5\u003e\n\u003ch4\u003eCustomizable Methods\u003c\/h4\u003e\n\u003cp\u003eThe HI903 can store up to 100 user-defined or standard titration methods. Each method may be customized and optimized for performance based on application and user requirements.\u003c\/p\u003e\n\u003ch4\u003eTitration Method Support\u003c\/h4\u003e\n\u003cp\u003eOnsite installation, training, and customization is available from one of our Applications or Service experts. Hanna offers continued support via phone or webinar for any questions you might have along the way.\u003c\/p\u003e\n\u003ch4\u003eAdaptable Standard Methods\u003c\/h4\u003e\n\u003cp\u003eOur technical experts can program and customize standard methods developed by such affiliations as ISO, ASTM, AOAC, AOCS, EPA, and more directly onto your titrator. Ask our Sales Consultants which standard methods are possible with our HI903 Karl Fischer system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/clearbeaker_goldliquid_copy.jpg\" alt=\"Methods of Analysis\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI903-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eKarl Fischer Volumetric Titrator HI903\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eKarl Fischer Volumetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003e100 ppm to 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003e1 ppm to 0.0001%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Units\u003c\/td\u003e\n\u003ctd\u003e%, ppm, mg\/g, µg\/g, mg, µg, mg\/mL, µg\/mL, mg\/pc, µg\/pc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Type\u003c\/td\u003e\n\u003ctd\u003eliquid or solid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePre-Titration Conditioning\u003c\/td\u003e\n\u003ctd\u003eautomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBackground Drift Correction\u003c\/td\u003e\n\u003ctd\u003eautomatic or user-selectable value\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndpoint Criteria\u003c\/td\u003e\n\u003ctd\u003efixed mV persistence, relative drift stop or absolute drift stop\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Type\u003c\/td\u003e\n\u003ctd\u003edynamic with optional pre-dispensing rate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResult Statistics\u003c\/td\u003e\n\u003ctd\u003emean, standard deviation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1% of full burette volume\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSyringe\u003c\/td\u003e\n\u003ctd\u003e5 mL precision ground glass with PTFE plunger\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eValve\u003c\/td\u003e\n\u003ctd\u003emotor-driven 3-way, PTFE liquid contact material\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTubing\u003c\/td\u003e\n\u003ctd\u003ePTFE with light block and thermal jacketing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDispensing Tip\u003c\/td\u003e\n\u003ctd\u003eglass, fixed position, anti-diffusing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Vessel\u003c\/td\u003e\n\u003ctd\u003econical with operation volume between 50-150 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSolvent Handling System\u003c\/td\u003e\n\u003ctd\u003esealed system, integrated diaphragm air pump\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePolarization Current\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 15, 20, 30 or 40 µA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e2 mV to 1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette\u003c\/td\u003e\n\u003ctd\u003e5 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Resolution\u003c\/td\u003e\n\u003ctd\u003e1\/40000 of the burette volume (0.125 µL per dose) with 5 mL burette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Type\u003c\/td\u003e\n\u003ctd\u003emagnetic, optically regulated, digital stirrer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Speed\u003c\/td\u003e\n\u003ctd\u003e200 to 2000 rpm; resolution 100 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitrator Methods\u003c\/td\u003e\n\u003ctd\u003eup to 100 methods (standard and user-defined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReports\u003c\/td\u003e\n\u003ctd\u003eup to 100 complete titration reports and drift rate reports can be stored\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP Conformity\u003c\/td\u003e\n\u003ctd\u003eGood Laboratory Practice and instrument data storage and printing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeripheral Devices\u003c\/td\u003e\n\u003ctd\u003econnections for VGA display, PC-keyboard, parallel printer, USB device input, RS232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7 in. (320 x 240 pixel) color LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003epolycarbonate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLanguages\u003c\/td\u003e\n\u003ctd\u003eEnglish, Portuguese. Spanish, and French\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100-240 VAC; -01models, US plug (type A); -02models, European plug (type C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003eoperating: 10 to 40°C (50 to 104°F), up to 95% RH\nstorage: -20 to 70°C (-4 to 158°F), up to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e390 x 350 x 380 mm (15.3 x 13.8 x 14.9 in)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eapproximately 10 kg (22 lbs)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI903-01\" target=\"_blank\" rel=\"noopener\"\u003eKarl Fischer Volumetric Titrator HI903\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871419826545,"sku":"HI933-02","price":919424.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi903.jpg?v=1792646609"},{"product_id":"mini-titrator-for-measuring-formol-number-in-wine-and-fruit-juice-hi84533","title":"Mini Titrator  for Measuring Formol Number in Wine and Fruit Juice - HI84533-02","description":"\u003cp\u003eThe content of amino acids and other nitrogen compounds in fruit juices and wines is expressed as total assimilable nitrogen and is determined by the formol method using an acid-base titration. The formol number (also known as formol index) is a parameter used for evaluation of the quality of fruit juices and wines.\u003c\/p\u003e\n\u003cp\u003eIn wines, the concentration of alpha amino acid in grapes change as a function of maturity and crop load (yield to vine size ratio). The concentration increases with fruit maturation and decreases with crop load. In the fermentation of wine, there is a minimum amount of amino acid and other nitrogen compounds (e.g., 150 to 200 mg\/L of yeast assimilable nitrogen) that has to be present in the must\/juice. Too low of an amount will result in a stuck fermentation in which there is not enough nitrogen for the yeast to thrive. Because of the importance of nitrogen in fermentation, it is desirable to determine the nitrogen concentration before fermentation.\u003c\/p\u003e\n\u003cp\u003eIn fruit juices, the formol nitrogen number is one of the basic parameters measured to determine quality. Depending on the type of fruit, the number can increase or decrease with maturity. In orange and grapefruit juice, lower values are observed when the fruit is not suitably mature or there has been frost damage. In pineapple juice, a low number could be indicative of over-dilution with water or a disproportionate amount of the core was used. To determine the adulteration of fruit juices, the formol number, along with the chromatography characterization of amino acids, can be used.\u003c\/p\u003e\n\u003ch5\u003eDouble Junction pH Electrode\u003c\/h5\u003e\n\u003cp\u003eThe HI84533 is supplied with the HI1131B glass body pH electrode. This electrode is refillable and features a double junction, minimizing the contamination of the electrode. This versatile electrode has a spherical sensing glass bulb that provides a wide surface of contact with a wine or fruit juice sample. The sensing portion is composed of high temperature glass, making it ideal for direct measurements or titrations in the beverage industry.\u003c\/p\u003e\n\u003ch5\u003ePiston Driven Dosing Pump\u003c\/h5\u003e\n\u003cp\u003eThe heart of the HI84533 is the piston driven burette pump. This type of dosing system uses a motor in which each dose is very precisely controlled and the volume dispensed is accurately determined. The piston driven burette is controlled dynamically so that the volume of titrant being dosed is automatically adjusted based on a voltage response of the previous dose. This type of dosing speeds up the titration process by allowing for more titrant to be dosed at the start of the titration and then very small doses as the endpoint is reached.\u003c\/p\u003e\n\u003ch5\u003eAutomatic Stirrer\u003c\/h5\u003e\n\u003cp\u003eThe built-in stirrer is automatically maintained at a speed of 600 rpm, regardless of the viscosity of the solution being titrated.\u003c\/p\u003e\n\u003ch4\u003eOn-Screen Features\u003c\/h4\u003e\n\u003cp\u003e\u003cstrong\u003eEasy-to-Use Interface\u003c\/strong\u003e The HI84533 has an intuitive user design with clearly defined keys and a large screen that is easy to navigate. The meter has a built-in tutorial mode that, when enabled, will walk the user step by step through the titration process. A dedicated HELP key is always available to allow access to content-specific information during both calibration and titration.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eProcedure Warnings\u003c\/strong\u003e Users are warned if there is an error in procedures such as the titration exceeded the maximum volume of titrant.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGraphic Mode \u003c\/strong\u003e This mini titrator displays in-depth data during titration, including a real-time graph of the titration curve.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLog-on-Demand\u003c\/strong\u003e The HI84533 allows for data logging of up to 400 samples: 200 titration results and 200 pH\/mV readings. Data can be stored and exported to a USB drive or a PC using the USB connection.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003epH\/mV Meter\u003c\/strong\u003e In addition to being an automatic titrator, the HI84533 also can be used as a pH\/mV meter. As a pH meter, it has many features of a professional grade benchtop including automatic calibration up to three points with four available buffers, a 0.01 pH resolution, accuracy of ±0.01 pH, automatic temperature compensation and comprehensive GLP data.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e Accuracy is always ensured with Hanna's unique CAL Check feature, which analyzes the response of the electrode during the calibration process. Based on electrode response in the buffer, indicators are displayed on screen to alert the user of potential problems during calibration. These indicators include Buffer Contaminated, Electrode Dirty\/Broken, and overall probe condition. The CAL Check function not only ensures an accurate pH reading when the HI84533 is used as a pH meter, but also an accurate titration since the endpoint of a total acidity titration is determined by a set pH value.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI84533-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMini Titrator for Measuring Formol Number in Wine and Fruit Juice - HI84533\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 16.0 pH; -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH \/ 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eone, two, or three-point calibration, four available buffers (4.01, 7.01, 8.20, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003emanual or automatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0°C; -4.0 to 248.0°F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C; 0.1°F; 0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4°C; ±0.8°F; ±0.4 K (@25ºC\/77ºF), without probe error\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Method\u003c\/td\u003e\n\u003ctd\u003eacid base titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Principle\u003c\/td\u003e\n\u003ctd\u003eendpoint titration, adjustable (pH 8.0 - 8.5 in 0.1 increments)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Range\u003c\/td\u003e\n\u003ctd\u003e(as N) Low Range: 2.14 to 28.57 meq\/L; 0.21 to 2.85 meq%; 30.0 to 400.0 mg\/L; High Range: 21.7 to 71.4meq\/L; 2.14 to 7.14 meq%; 300 to 1000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.01 meq\/L; 0.01 meq%; 0.1 mg\/L; High Range: 0.1 meq\/L; 0.01 meq%; 1 mg\/L;\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L or 3% of reading, whichever is greater (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample Size\u003c\/td\u003e\n\u003ctd\u003eLow Range: 10 mL; High Range: 5 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTitration Pump Speed\u003c\/td\u003e\n\u003ctd\u003e10 mL\/min\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI1131B glass body, refillable, with BNC connector and 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eHI7662-T stainless steel temperature probe with 1 m (3.3’) cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eLog-on-demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 400 ( 200 titrations, 200 pH\/mV readings)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 USB port for data storage and export to a PC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBuilt-in Magentic Stirrer\u003c\/td\u003e\n\u003ctd\u003eBuilt-in magnetic stirrer at 600 rpm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e235 x 200 x 150 mm (9.2 x 7.9 x 5.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.9 kg (67.0 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI84533 is supplied with HI1131B pH electrode, HI7662-M temperature probe, HI7082 electrode fill solution (30 mL), HI84533-50 titrant solution (230 mL), HI84533-55 pump calibration solution (120 mL), HI84533-61 formol base reagent (230 mL), HI84533-62 pH adjustment reagent (30 mL), HI84533-60 hydrogen peroxide reagent (30 mL), 100 mL beakers (2), tube set (aspiration tube with titrant bottle cap and dispensing tube with tip), dosing pump valve, 5 mL syringe, 1 mL plastic pipette, cleaning solution sachets for wine deposits and wine stains (2), 12 VDC adapter, instruction manual and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI84533-01\" target=\"_blank\" rel=\"noopener\"\u003eMini Titrator for Measuring Formol Number in Wine and Fruit Juice - HI84533\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871457476977,"sku":"HI84533-02","price":100012.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi84533_mini-angle.png?v=1792646942"},{"product_id":"advanced-automatic-potentiometric-titrator-hi932","title":"Advanced Automatic Potentiometric Titrator - HI932","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eTake your testing to the next level with our Automatic Titrator (HI932) and set a higher standard for quality at your laboratory or business.\u003c\/p\u003e\n\u003cp\u003eWe’ve meticulously designed this titrator to not just help you meet industry and application requirements, but to surpass them altogether.\u003c\/p\u003e\n\u003cp\u003eOur Automatic Titrator is durable and built to withstand the harsh chemicals used during titrations. Up for the task at hand, this titrator unit is manufactured with a strong Cycoloy® body and chemically resistant PTFE tubing.\u003c\/p\u003e\n\u003cp\u003eWith its compact size, our Automatic Titrator requires less benchtop space and fits seamlessly into any testing environment.\u003c\/p\u003e\n\u003cp\u003eAt Hanna Instruments, we understand that purchasing an automatic titration system is a big decision and there are a multitude of considerations to make beforehand. Our team of experts are here to answer any questions that you may have and can help you determine the best solution for your application and testing requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eExperience our Automatic Titrator\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(300px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-burettes-minimal-titrant.webp\" alt=\"Measure with precision\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMeasure with precision\u003c\/h4\u003e\n\u003cp\u003eGet accurate and consistent results at just the push of a button. Our Automatic Titrator is built with a 40,000 step dosing pump, capable of dosing extremely small volumes of titrant and achieving an exact endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/attain-repeatable-results-300by200.webp\" alt=\"Attain repeatable results\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAttain repeatable results\u003c\/h4\u003e\n\u003cp\u003eSeveral shift changes can occur at labs. Our Automatic Titrator arrives with preprogrammed methods which can be optimized to match your testing needs. Users can perform and replicate tests the same way each time.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/decisions-300by200-kk.webp\" alt=\"Meet quality standards\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMeet quality standards\u003c\/h4\u003e\n\u003cp\u003eAdhering to strict requirements is an absolute must. Be ready with our Automatic Titrator! Gain traceability and produce customizable analysis reports. Store required data for each application and record all GLP information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-decision-2.webp\" alt=\"Make decisions and adjustments on the spot\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMake decisions and adjustments on the spot\u003c\/h4\u003e\n\u003cp\u003eStart taking control of your testing with our Automatic Titrator. By testing in-house, you can avoid delays and stay proactive. Discover potential quality issues quickly, take corrective action, and implement changes when needed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-free-time.webp\" alt=\"Free up time and increase productivity\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFree up time and increase productivity\u003c\/h4\u003e\n\u003cp\u003eLet our Automatic Titrator do the bulk of the work for you! While a titration is running, you can  focus on other important tasks simultaneously. Cross more things off your priority list and improve overall efficiency.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-methods.webp\" alt=\"Test confidently and eliminate the hassle\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eTest confidently and eliminate the hassle\u003c\/h4\u003e\n\u003cp\u003eUser-friendly, our Automatic Titrator makes testing simple and convenient. Don't worry about getting lost or overloaded with information. This unit is equipped with intuitive screens and menus for easy navigation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-industries.webp\" alt=\"Which industries use Automatic Titrators?\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eWhich industries use Automatic Titrators?\u003c\/h4\u003e\n\n\u003cul\u003e\n\u003cli\u003eFood\u003c\/li\u003e\n\u003cli\u003eBeverage Manufacturing\u003c\/li\u003e\n\u003cli\u003eLaboratory\u003c\/li\u003e\n\u003cli\u003eEducation and Research\u003c\/li\u003e\n\u003cli\u003eIndustrial\u003c\/li\u003e\n\u003cli\u003ePetrochemical\u003c\/li\u003e\n\u003cli\u003eMunicipalities\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eApplications and standard methods\u003c\/h2\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px; max-height: 560px; overflow-y: auto;\"\u003e\n\u003ctable data-filter-table data-filter-columns=\"0,1,2,3\"\u003e\n\u003cthead\u003e\u003ctr\u003e\n\u003cth\u003eIndustry\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSample\u003c\/th\u003e\n\u003cth\u003eStandard Methods\u003c\/th\u003e\n\u003c\/tr\u003e\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkali, Free \u0026amp; Total\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eMineral Carbonized Concrete\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Food, Beverage, Industrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eAmine Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D6979\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eSurfactants, Anionic\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eAscorbic Acid\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eBoric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Cleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eBoron Trioxide\u003c\/td\u003e\n\u003ctd\u003eTreating Solutions, Treated Wood\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eSurfactants, Cationic\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003eASTM D5806\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eCaustic and Aluminum\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eChloride\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government\u003c\/td\u003e\n\u003ctd\u003eChloride\u003c\/td\u003e\n\u003ctd\u003eAnimal Feed\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government, Food, Beverage, Water Treatment\u003c\/td\u003e\n\u003ctd\u003eChloride\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eSodium Cyanide\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eDegree of Neutralization\u003c\/td\u003e\n\u003ctd\u003eHair Fixatives\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eFluoride\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eFormol Number\u003c\/td\u003e\n\u003ctd\u003eWines, Juices\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eFree Fatty Acids\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Oils\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eGlutaraldehyde\u003c\/td\u003e\n\u003ctd\u003eDisinfectants\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory\u003c\/td\u003e\n\u003ctd\u003eGold\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Calcium (ISE)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Total \u0026amp; Calcium (ISE)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Calcium (Photometric)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment, Environmental, Industrial\u003c\/td\u003e\n\u003ctd\u003eHardness, Total \u0026amp; Calcium (Photometric)\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eChromium, Hexavalent\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eHydrazine\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eHydrogen Peroxide\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003ePeracetic Acid\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eHydroxyl Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSodium Hypophosphite\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Cleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIron, Ferric\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIron, Ferrous\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIron, Total\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eLime\/Calcium Hydroxide\u003c\/td\u003e\n\u003ctd\u003eLimestone, Quicklime, Hydrated Lime\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eIsocyanate (NCO)\u003c\/td\u003e\n\u003ctd\u003ePolyurethane Raw Materials\u003c\/td\u003e\n\u003ctd\u003eISO 14896; ASTM D5155; ASTM D2572\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNeutralization\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNickel Chloride\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNickel\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNitric Acid\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNitric Acid and Hydrofluoric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eNitric Acid, Hydrofluoric Acid, and Titanium\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eOrganic Chlorides\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003ctd\u003eASTM D4929\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Food, Beverage\u003c\/td\u003e\n\u003ctd\u003ePeroxide Value\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Oils\u003c\/td\u003e\n\u003ctd\u003eAOAC 965.33; AOCS Cd 8b-90\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003ePhosphoric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Cleaners, Detergents\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eReducing Sugars\u003c\/td\u003e\n\u003ctd\u003eWines, Juices\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eResin\u003c\/td\u003e\n\u003ctd\u003eHair Fixatives\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government, Food, Beverage\u003c\/td\u003e\n\u003ctd\u003eSalt \/ Sodium Chloride\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory, Industrial, Government, Food, Beverage\u003c\/td\u003e\n\u003ctd\u003eSodium Bicarbonate\u003c\/td\u003e\n\u003ctd\u003eFoodstuffs, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSodium Dichromate\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSodium Hypochlorite \/ Bleach\u003c\/td\u003e\n\u003ctd\u003eCleaners, Detergents, Water\/Wastewater\u003c\/td\u003e\n\u003ctd\u003eASTM D2022\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide, Free\u003c\/td\u003e\n\u003ctd\u003eWines, Juices, Beverages\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eSulfur Dioxide, Total\u003c\/td\u003e\n\u003ctd\u003eWines, Juices, Beverages\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSulfuric Acid\u003c\/td\u003e\n\u003ctd\u003ePlating Baths, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eSulfuric Acid and Aluminum\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eThiocyanate\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTin\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eTitratable Acidity\u003c\/td\u003e\n\u003ctd\u003eFood\/Beverage, Various\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Acid Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D664\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Acid Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D974\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Base Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D2896\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Base Number\u003c\/td\u003e\n\u003ctd\u003ePetroleum Products, Various\u003c\/td\u003e\n\u003ctd\u003eASTM D4739\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eTotal Inorganic Carbon\u003c\/td\u003e\n\u003ctd\u003eDigestate\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eVolatile Fatty Acids\u003c\/td\u003e\n\u003ctd\u003eDigestate\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood, Beverage, Laboratory\u003c\/td\u003e\n\u003ctd\u003eVolatile Acidity\u003c\/td\u003e\n\u003ctd\u003eWines, Juices, Beverages\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial, Laboratory, Government\u003c\/td\u003e\n\u003ctd\u003eZinc\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eTailor to your testing needs\u003c\/h2\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(260px, 1fr)); gap: 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"border: 1px solid #c9d6e6; border-radius: 8px; padding: 20px; background: #f7f9fc;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCan you customize titration methods?\u003c\/h4\u003e\n\u003cp style=\"margin: 0;\"\u003eYes, of course! With our Automatic Titrator, you can modify titration methods to suit your application requirements. Titrate for a variety of published methods and store up to 100 user-defined, standard titration, and direct measurement methods\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c9d6e6; border-radius: 8px; padding: 20px; background: #f7f9fc;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAre you able to perform different titration types?\u003c\/h4\u003e\n\u003cp style=\"margin: 0;\"\u003eYes, this is possible! Pair with the right electrode and complete numerous standard and back titrations as well as direct pH, ORP, and ion-selective readings\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"border: 1px solid #c9d6e6; border-radius: 8px; padding: 20px; background: #f7f9fc;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eWhat is the linked methods function?\u003c\/h4\u003e\n\u003cp style=\"margin: 0;\"\u003eAvailable for certain applications, this unique approach saves you time and allows you to measure two parameters in one sample with a single method.  One sample + One method = Two results\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/network-box-pagehi932-b.jpg\" alt=\"Pair your titrator with our Network Box\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eEnsure data integrity\u003c\/h4\u003e\n\u003ch5\u003ePair your titrator with our Network Box\u003c\/h5\u003e\n\n\u003cul\u003e\n\u003cli\u003eAllows our Automatic Titrator (HI932) to integrate with a Laboratory Information Management System (LIMS) via a secure Ethernet connection for text\/PDF data exchange\u003c\/li\u003e\n\u003cli\u003eSupports USB printing and enables Titrator generated files including methods, reports, and data logs to be printed\u003c\/li\u003e\n\u003cli\u003eWith FTPS and SMB network transfer capabilities, data files can be moved from the Titrator to network storage\u003c\/li\u003e\n\u003cli\u003eA secure TLS connection encrypts transferred data, ensuring data integrity\u003c\/li\u003e\n\u003cli\u003eOur Network Box is a Trusted Platform Module (TPM) 2.0 device and provides hardware-based security for key storage, encryption, and platform integrity\u003c\/li\u003e\n\u003cli\u003eProvides upgrade support and can install updates to patch vulnerabilities and add features\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, max(440px, calc((100% - 48px) \/ 2))), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932-Flexible-electrode-holder.jpg\" alt=\"Modifiable electrode holder\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eModifiable electrode holder\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHold up to three electrodes, four tubes, and one temperature probe\u003c\/li\u003e\n\u003cli\u003eChange the electrode guide to use electrodes with different diameters\u003c\/li\u003e\n\u003cli\u003eCreate the best tube alignment for titrations with a rotating electrode holder\u003c\/li\u003e\n\u003cli\u003eGain extra space and accommodate larger beakers by reversing the electrode holder\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931HI932-adjustable.jpg\" alt=\"Adjustable arm\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAdjustable arm\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eGet the versatility you need and use the press-to-release button for simple height control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/stirrer-689by460.jpg\" alt=\"Convenient stirrer\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eConvenient stirrer\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSwap the overhead stirrer with a stir plate and stir bar for access to smaller volume titrations\u003c\/li\u003e\n\u003cli\u003eEnsure consistent stirring with built-in speed control\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI931-HI932-removable-burrett.jpg\" alt=\"Exchangeable burette system\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eExchangeable burette system\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSave time with our Clip-Lock™ burette system. Exchange titrants and reagents in just a few seconds and prevent cross-contamination\u003c\/li\u003e\n\u003cli\u003eFasten the Clip-Lock easily and listen for an audible clicking sound to signal when it is securely in place\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 200px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi932-burettes-minimal-titrant.jpg\" alt=\"Automatic reagent addition\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAutomatic reagent addition\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProgram a peristaltic pump or a second burette to dispense reagent prior to titration or a direct measurement. This prevents human-error, incorrect volumes or simply forgetting to add reagent\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi922.jpg\" alt=\"Add an Autosampler\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eBetter together\u003c\/h4\u003e\n\u003ch5\u003eAdd an Autosampler\u003c\/h5\u003e\n\u003cp\u003eImprove your titrations with this duo! Our Automatic Titrator (HI932) and Autosampler (HI922) join forces to provide you with the ultimate testing experience. \u003c\/p\u003e\n\u003cp\u003eOur Autosampler (HI922) interfaces directly with this titrator unit for easy, fast, and accurate testing. \u003cbr\u003e\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eWhen paired together, you can:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003ePerform titration methods in sequence\u003c\/li\u003e\n\u003cli\u003eTitrate for multiple samples. Run automated sample titrations consecutively using a 16 or 18 sample tray\u003c\/li\u003e\n\u003cli\u003eStay informed with status indicator lights. These change color to notify you which testing stage you are in or alert you to a problem\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/support-hi932-page.jpg\" alt=\"We're here for you\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eWe're here for you\u003c\/h4\u003e\n\u003cp\u003eWhen you invest in a titrator with Hanna, you gain an entire team of experts ready to support you and your testing needs. \u003cbr\u003e\u003cbr\u003eWe work with you every step of the way to ensure your testing success. From titrator installation and training to method customization and preventative maintenance, we’ve got you covered. \u003cbr\u003e\u003cbr\u003eGet peace of mind and keep your titrator operating at optimal performance! Ask us about our titrator service plan options.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/manual.jpg\" alt=\"Tired of manual titrations? Make the switch\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eTired of manual titrations? Make the switch\u003c\/h4\u003e\n\u003cp\u003eWe understand that making the move from manual to automatic titration can seem overwhelming at first. At Hanna, we make this transition easy. \u003cbr\u003e\u003cbr\u003eNot sure if you are ready? Check out our top 5 reasons for why you should automate and test with a titrator.\u003c\/p\u003e\n\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eResources\u003c\/h2\u003e\n\u003cdiv data-desc-tabs style=\"margin: 0 0 48px;\"\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eWhat's Included\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eAdvanced Automatic Potentiometric Titrator (HI932)\u003c\/li\u003e\n\u003cli\u003ePump assembly\u003c\/li\u003e\n\u003cli\u003eBurette assembly (burette with 25 mL syringe, aspiration tube with fitting and protection tube, dispensing tube with dispensing tip, protection tube, and tube guide, tube locks, tool for burette cap removal, and light spectrum protection screen)\u003c\/li\u003e\n\u003cli\u003eElectrodes holder and stirrer (electrode holder, overhead stirrer, propellers (3 pcs.), and support rod)\u003c\/li\u003e\n\u003cli\u003eBurette blank support\u003c\/li\u003e\n\u003cli\u003ePump and burette locking screws with plastic head\u003c\/li\u003e\n\u003cli\u003eTemperature sensor (1 pc.)\u003c\/li\u003e\n\u003cli\u003eShorting cap (1 pc.)\u003c\/li\u003e\n\u003cli\u003ePower adapter (1 pc.)\u003c\/li\u003e\n\u003cli\u003eUSB flash drive (1 pc.)\u003c\/li\u003e\n\u003cli\u003eUSB cable (1 pc.)\u003c\/li\u003e\n\u003cli\u003eHI900 PC application (installation kit on USB flash drive)\u003c\/li\u003e\n\u003cli\u003eInstruction manual (1 pc.)\u003c\/li\u003e\n\u003cli\u003eQuality certificate (1 pc.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eSecurity Features\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSecure the titrator unit. Determine appropriate permission settings for each user, administrator or non-administrator level, to prevent unwanted edits or changes to titration method options and results\u003c\/li\u003e\n\u003cli\u003eAdministrators can set a PIN code on the titrator unit to protect against unauthorized access\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eReporting Capabilities\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eStore up to 100 titration and pH\/mV\/ISE reports\u003c\/li\u003e\n\u003cli\u003eProduce customizable analysis reports and store the required data for each application. The multi-select option also makes batch processing simple\u003c\/li\u003e\n\u003cli\u003eRecord all required GLP (Good Laboratory Practice) information automatically for each sample. This includes sample identification, company and operator name, date, time, electrode ID codes, and calibration data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv data-desc-tab\u003e\n\u003ch4 data-desc-tab-title\u003eConnection Options\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eExport and transfer data such as titration methods, reports, and software updates via a USB flash drive or PC\u003c\/li\u003e\n\u003cli\u003eConnect an analytical balance to the titrator unit for automatic sample weight entry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalysis Type\u003c\/td\u003e\n\u003ctd\u003eStandard titration (Standardization, Fixed pH \/ mV, Equivalence point pH \/ mV)\u003cbr\u003eBack titration\u003cbr\u003eDirect reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEndpoint Mode\u003c\/td\u003e\n\u003ctd\u003eFixed mV\u003cbr\u003eFixed pH\u003cbr\u003emV equivalence point (up to 5 points, 1\u003csup\u003est\u003c\/sup\u003e or 2\u003csup\u003end\u003c\/sup\u003e derivative)\u003cbr\u003epH equivalence point (Up to 5 points, 1\u003csup\u003est\u003c\/sup\u003e or 2\u003csup\u003end\u003c\/sup\u003e derivative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Size\u003c\/td\u003e\n\u003ctd\u003e5 mL, 10 mL, 25 mL, 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Flow Rate\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.3 mL to 2 x burette volume per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBurette Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.005 mL (5 mL burette)\u003cbr\u003e±0.010 mL (10 mL burette)\u003cbr\u003e±0.025 mL (25 mL burette)\u003cbr\u003e±0.050 mL (50 mL burette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Type\u003c\/td\u003e\n\u003ctd\u003eOverhead\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Range\u003c\/td\u003e\n\u003ctd\u003e200 to 2500 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Resolution\u003c\/td\u003e\n\u003ctd\u003e100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Calibration\u003c\/td\u003e\n\u003ctd\u003esingle point, offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eup to 5 points with standard or custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003e1×10\u003csup\u003e–6\u003c\/sup\u003e to 9.999×10\u003csup\u003e10\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e1 \/ 0.1 \/ 0.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e± 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration\u003c\/td\u003e\n\u003ctd\u003eup to 5 points\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.0 to 105 °C\u003cbr\u003e23.0 to 221.0 °F\u003cbr\u003e268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C \/ ±0.2 °F \/ ±0.1K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage Methods\u003c\/td\u003e\n\u003ctd\u003eUp to 100 titration methods (standard and user-defined)\u003cbr\u003eUp to 30 autosampler sequences\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData Storage Reports\u003c\/td\u003e\n\u003ctd\u003eUp to 100 titration and pH \/ mV \/ ISE reports\u003cbr\u003eUp to 40 autosampler tray reports (e.g. 720 reports for 18 beaker tray)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections Measurement\u003c\/td\u003e\n\u003ctd\u003e2 × BNC socket (pH, ORP, ISE half-cell, and ISE combination electrodes)\u003cbr\u003e2 × 4 mm banana socket (reference electrode)\u003cbr\u003e2 × RCA socket (temperature sensor)\u003cbr\u003e2 × 6-pin connector (stirrer)\u003cbr\u003e2 × 3.5 mm Jack connector (digital sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnections Peripheral\u003c\/td\u003e\n\u003ctd\u003e1 × DB-9 socket (serial interface)\u003cbr\u003e2 × USB type C (external PC keyboard, PC connection)\u003cbr\u003e1 × 5-pin connector (balance)\u003cbr\u003e1 × USB standard A (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eElectrode Holder\u003c\/td\u003e\n\u003ctd\u003e4 × multi-purpose slots (titrant \/ reagent tubes)\u003cbr\u003e3 × 12-mm electrode slots\u003cbr\u003e1 × temperature sensor slot\u003cbr\u003e1 × overhead stirrer slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e5.7 in. graphical color display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 - 240 VAC, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Draw\u003c\/td\u003e\n\u003ctd\u003e0.5 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure Material\u003c\/td\u003e\n\u003ctd\u003eABS, PC-ABS, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeypad\u003c\/td\u003e\n\u003ctd\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e315 × 205 × 375 mm (12.4 × 8.1 × 14.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 4.3 kg (9.5 lbs.) with 1 pump, stirrer, and sensors\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOperating Environment\u003c\/td\u003e\n\u003ctd\u003e10 to 40 °C (50 to 104 °F); up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStorage Environment\u003c\/td\u003e\n\u003ctd\u003e–20 to 70 °C (–4 to 158 °F); up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/MAN932_SW-2.2.2_06_26.pdf\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Automatic Potentiometric Titrator Manual (HI932)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871462064497,"sku":"HI932","price":1803515.63,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI932-Right-Front-Raised-2-4__30029.1746719177.webp?v=1792646987"}],"url":"https:\/\/hannainst.in\/collections\/parameter-titration.oembed","provider":"hanna","version":"1.0","type":"link"}