{"title":"Benchtop Meters – pH\/ORP","description":"","products":[{"product_id":"edge-dedicated-ph-orp-meter-hi2002","title":"edge ® Dedicated pH\/ORP Meter - HI2002-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHanna Instruments is proud to introduce the world’s most innovative pH\/ORP meter: edge®.\u003c\/p\u003e\n\u003cp\u003eedge’s groundbreaking design is the culmination of Hanna’s vision, design capabilities, integrated production and world class R\u0026amp;D. edge is a single, easy to use meter that can measure \u003cstrong\u003epH and ORP\u003c\/strong\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2002_calcheck.png\" alt=\"edge screen size\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAdvanced pH Electrode Diagnostics\u003c\/h4\u003e\n\u003cp\u003eedge features advanced pH electrode diagnostics to ensure worry-free measurements. Diagnostics include Hanna’s exclusive CAL Check™ feature that alerts users to potential problems during calibration. The Sensor Check™ feature for glass and junction integrity is enabled when using optional pH electrodes with a matching pin.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2002_touch.png\" alt=\"Capacitive Touch\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCapacitive Touch\u003c\/h4\u003e\n\u003cp\u003eedge features a capacitive touch keypad that gives a distinctive, modern look. The keypad has a fast response and is sensitive enough to be used with laboratory gloves. Since the keypad is part of the screen, there are no buttons to get clogged with sample residue.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2002_screen.png\" alt=\"Clear Full Text Readout\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLarge, Easy to Read LCD\u003c\/h4\u003e\n\u003cp\u003eedge features a 5.5” LCD display that you can clearly view from over 5 meters. The large display and it’s wide 150° viewing angle provide one of the easiest to read LCDs in the industry.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI2002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e® Dedicated pH\/ORP Meter - HI2002\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 16.000 pH (Standard Mode), -2.00 to 16.00 pH (Basic Mode)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 pH, 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH, ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e5 points (standard mode)  1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (basic mode) 4.01; 6.86; 7.01; 9.18; 10.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003edigital pH electrode input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±999.9 mV); ±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±1000.0 pH in mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 ºC, -4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C, ±0.9 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI11310 pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003eintegrated into pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003elog-on-demand; log-on-stability, interval logging\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 1000 records; log-on-demand (max. 200 logs); manual log-on-stability (max. 200 logs); interval logging (max. 600 samples; 100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 micro USB port for charging and PC connectivity, 1 USB port for flash storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Timeout Reminder\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutoend\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003esegmented LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003ebuilt-in rechargeable battery with up to 8 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7mm (8” x 5.5” x 0.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g (8.82 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003e® HI2002 includes benchtop docking station with electrode holder, wall mount cradle, USB cable, HI11310 glass body refillable pH electrode with temperature sensor, 2 sachets each of pH 4, 7, 10, cleaning solution, 5 VDC power adapter and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI2002-01\" target=\"_blank\" rel=\"noopener\"\u003e® Dedicated pH\/ORP Meter - HI2002\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871179178353,"sku":"HI2002-02","price":61269.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2002_meter_wallmount.jpg?v=1792645823"},{"product_id":"professional-benchtop-ph-mv-meter-with-built-in-printer-hi122","title":"Professional Benchtop pH\/mV Meter with Built-in Printer - HI122-02","description":"\u003cp\u003eThe HI122 pH\/mV and temperature benchtop meter features CAL Check™,  a clear and informative LCD display,  data logging capability,  and computer connectivity. The HI122 has a single input channel that allows for measurement of pH and ORP. Readings for pH can be manually or automatically compensated for temperature variations with the separate HI7662-T temperature probe from -20.0 to 120.0℃.\u003c\/p\u003e\n\u003cp\u003eThe HI122 can be calibrated up to five points with a choice of seven standard buffers or two custom buffers. All GLP data regarding pH and relative mV calibration is stored for the user to review when necessary. The built-in impact printer incorporated into the HI122 allows for on demand printing of a complete set of information based on the measured,  set or recorded data while in various modes such as,  measurement mode,  GLP or Setup mode.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - Hanna's exclusive CAL Check™ diagnostics system ensures accurate pH readings every time by alerting users of potential problems during the calibration process. The CAL Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions during calibration. After the guided calibration process,  the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eAutomatic Calibration\u003c\/strong\u003e - \u003c\/strong\u003epH calibration can be performed up to five points with seven standard buffers and two custom buffers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Impact Printer\u003c\/strong\u003e - The built-in impact printer incorporated into the HI122 uses regular paper that does not fade with time. The information related to measurements being taken can be printed while in measurement mode,  GLP or Setup mode. This meter also allows users to print detailed information in four languages for specific help screens and instrument set-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI1131P pH Electrode\u003c\/strong\u003e - The HI122 is supplied with the HI1131P glass body,  double junction,  refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction and HT glass design allows the HI1131P to be used in a wide variety of applications ranging from samples with metals and Tris buffer to samples at elevated temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e - Temperature for pH measurements can be compensated for automatically (ATC) or manually (MTC) from -20.0 to 120.0℃ with the use of the supplied HI7662-T temperature probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGLP Data\u003c\/strong\u003e - The calibration data for each channel including date,  time,  standards used,  offset,  and slope can be accessed at any time through the HI122 menu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e - The log-on-demand feature accepts the recording of 50 samples. Interval logging allows up to 1000 data points to be recorded and allows the user to specify time intervals from 5 seconds to 180 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Transfer\u003c\/strong\u003e - With a built-in logging function,  measurements are stored in non-volatile memory,  and can be transferred to a PC through the RS232 port.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI122-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Professional Benchtop pH\/mV Meter with Built-in Printer - HI122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e -2.00 to 16.00 pH, -2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH, 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH, ±0.002 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e automatic, up to five-point calibration with seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and two custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic or manual from -20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e ±999.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mV; 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.2 mV (±699.9 mV); ±0.5 mV (±999.9 mV); ±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Relative Offset\u003c\/td\u003e\n\u003ctd\u003e ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -20.0 to 120.0 ºC, -4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.4°C (±0.7°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e HI1131P pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e HI7662-T temperature probe (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e log-on-demand; interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e 50 samples (25 per channel); 1000 samples (500 per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Interval\u003c\/td\u003e\n\u003ctd\u003e 5 seconds to 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e RS232 serial port, opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter\u003c\/td\u003e\n\u003ctd\u003e built-in dot matrix printer, with 44 mm plain paper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 280 x 203 x 84 mm (11.0 x 8.0 x 3.3”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.9 kg (4.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI122 is supplied with HI1131P pH electrode, HI7662-T temperature probe, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI7082 3.5M KCl electrolyte solution (30 mL), (5) paper rolls, 12 VDC adapter and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI122-01\"\u003eProfessional Benchtop pH\/mV Meter with Built-in Printer - HI122\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871200280945,"sku":"HI122-02","price":176189.85,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi122_2.jpg?v=1792645872"},{"product_id":"advanced-ph-orp-benchtop-meter-hi6221-02","title":"Advanced pH\/ORP Benchtop Meter- HI6221-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eLaboratory\u003c\/h2\u003e\n\u003cp\u003eMeasure pH\/mV (pH) or mV\/Rel. mV (ORP) with Temperature\u003c\/p\u003e\n\u003cp\u003eHI6221 is a streamlined benchtop meter with a large touch screen display, comprised of a housing and an integrated pH \/ ORP measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the benchtop meter is delivered with Hanna Instruments HI1131B double junction combination pH electrode, together with HI7662-TW temperature probe.\u003c\/p\u003e\n\u003cp\u003eHI1131B is a glass body, double junction, refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction reference and HT glass design allow the HI1131B to be used in a wide variety of applications including samples with metals and elevated temperatures. Probe connection to the unit is secured through a galvanically isolated BNC connection. HI7662-TW stainless steel temperature probe allows the meter to automatically temperature compensate (ATC) pH measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221_front-rear.png\" alt=\"front back\" width=\"1250\" height=\"691\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThis system responds to a complex range of measurement and monitoring requirements, providing accuracy, reproducibility, and reliability. HI6221 is supplied with an electrode holder that has a flexible arm. The holder can be mounted quickly and provides secure support for electrodes while taking measurements in sample containers.\u003c\/p\u003e\n\u003ch4\u003eUser interface\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003cli\u003eThe user can select between five different views:\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eMeasurement\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH\/mV (pH) or mV\/Rel.mV (ORP) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor and system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic (using temperature probe) or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for pH\/ORP measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCalibration\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e5-point pH calibration with automatic recognition for standard buffers (Hanna and NIST buffers)\u003c\/li\u003e\n\u003cli\u003eChoice of standard or custom buffers for calibration\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLogging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eConnectivity features \u0026amp; services\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection\u003c\/li\u003e\n\u003cli\u003eUSB type A for USB stick, keyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHelp section for meter guidance\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eVideo support presentation of main functionalities\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cem\u003eCustomize calibration options such as Last Calibration, Automatic, semi-automtic or manual calibration, First Calibration Point, daily or periodic Calibration Reminder, and buffer Groups.\u003c\/em\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_08_Image_0007.jpg\" alt=\"\" width=\"460\" height=\"276\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/LF_HI6221_1p0_1222_Page_02_Image_0001.png\" alt=\"\" width=\"450\" height=\"450\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eCapacitive touch screen with multi-touch support\u003c\/h2\u003e\n\u003cp\u003eThe benchtop unit has a 7-inch color display with 800 x 480p resolution. The capacitive, multi-touch screen supports video playback and data plotting.\u003c\/p\u003e\n\u003ch2\u003eSystem Menu key\u003c\/h2\u003e\n\u003cp\u003eThis key will enter the system menu where User accounts, System Settings, and Logging can be configured. The Help menu is also accessed on the system menu screen.\u003c\/p\u003e\n\u003ch2\u003eMeasurement setup menu\u003c\/h2\u003e\n\u003cp\u003eOpens sensor setup parameters.\u003c\/p\u003e\n\u003ch2\u003eDirect\/Autohold readings\u003c\/h2\u003e\n\u003cp\u003eWhen Direct\/Autohold is selected, measurement reading is held on display when measurement stability is reached. This option removes the subjective nature of stability as a measurement that has not reached equilibrium will not be used.\u003c\/p\u003e\n\u003cp\u003eWhen not selected, sample measurements are displayed continuously.\u003c\/p\u003e\n\u003ch4\u003eHI6221 is supplied with:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eHI1131B pH electrode; HI7662-TW temperature probe\u003c\/li\u003e\n\u003cli\u003epH calibration starter kit consisting of:\u003cul\u003e\n\u003cli\u003epH 4.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 7.01 buffer solution sachet (4 pcs.)\u003c\/li\u003e\n\u003cli\u003epH 10.01 buffer solution sachet (2 pcs.)\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHI700601 electrode cleaning solution sachet (2 pcs.)\u003c\/li\u003e\n\u003cli\u003eHI7082 3.5M KCl electrolyte solution (30 mL)\u003c\/li\u003e\n\u003cli\u003eHI764060 electrode holder\u003c\/li\u003e\n\u003cli\u003eCapillary pipette\u003c\/li\u003e\n\u003cli\u003e24 VDC power adapter\u003c\/li\u003e\n\u003cli\u003eUSB-C to USB-A cable\u003c\/li\u003e\n\u003cli\u003eQuick reference guide with instrument quality certificate.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last signiﬁcant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last signiﬁcant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C; -4.0 to 248.0 °F; 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C \/ 0.1 °F \/ 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C \/ ±0.4 °F \/ ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRelative mV oﬀset range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Calibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Standard buﬀers\u003c\/td\u003e\n\u003ctd\u003epH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom buﬀers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Custom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration 1st calibration point\u003c\/td\u003e\n\u003ctd\u003eOﬀset or Points (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDaily: 0 m in. to 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003ePeriodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect; Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Isopotential\u003c\/td\u003e\n\u003ctd\u003e7.000 or 4.010\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling rate\u003c\/td\u003e\n\u003ctd\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (pH, mV, Rel.mV, Abs.mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Basic\u003c\/td\u003e\n\u003ctd\u003eTemperature, Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eLast calibration date, electrode oﬀset, average slope, and electrode condition\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003epH (or mV) and temperature versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle \/ Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003eUsers Up to 9 users and adm in. account (default):\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP \/ Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (2.65 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6221-02\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced pH\/ORP Benchtop Meter- HI6221-02\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871319884145,"sku":"HI6221-02","price":122546.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6221-head-on-700x700-cd07ed0c-fd8c-42df-a0a8-112410be6851_4_2.jpg?v=1792646147"},{"product_id":"ph-and-ec-tds-and-do-starter-benchtop-meter-hi2600","title":"pH and EC\/TDS and DO Starter Benchtop Meter - HI2600","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003cthead style=\"color: #292f36;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"font-weight: bold;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eusing pH electrode HI11310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−2.00 to 16.00 pH\n−2.000 to 16.000 pH *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\n0.001 pH *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\n±0.002 pH *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C **\n(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C; (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to three (five*)\npoints Option to select from five (seven*) standard buffers: pH 1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45* and two custom buffers*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600 - using ORP electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI36180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±999.9 mV)\n±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C**(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, using integral temperature sensor\n−5.0 to 100.0 °C (23.0 to 212.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* records organized in:\n• Manual log-on-demand, maximum 200 logs\n• Manual log-on-stability, maximum 200 logs\n• Interval logging*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600 - using the four-ring conductivity probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI763100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 μS\/cm\n30.0 to 299.9 μS\/cm\n300 to 2999 μS\/cm\n3.00 to 29.99 mS\/cm\n30.0 to 200.0 mS\/cm\nup to 500.0 mS\/cm absolute conductivity***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 μS\/cm\n0.1 μS\/cm 1 μS\/cm\n0.01 mS\/cm 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\n(±0.05 μS\/cm or 1 digit,whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 ppm (mg\/L)\n15.0 to 149.9 ppm (mg\/L)150 to 1499 ppm (mg\/L)\n1.50 to 14.99 g\/L\n15.0 to 100.0 g\/L\nup to 400.0 g\/L absoluteTDS ‡ (with 0.80 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\n0.1 ppm\n1 ppm 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity* Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0 % NaCl\n2.00 to 42.00 PSU\n0.00 to 80.00 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity* Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% NaCl\n0.01 PSU\n0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity* Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI763100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C**(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI763100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI763100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCell factor calibration\nSix standards available: 84 µS\/cm, 1413 μS\/cm 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm\nOne point offset: 0.00 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\"Salinity calibration* (% NaCl only)\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point with HI7037 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• Automatic, −5 to 100 °C (23 to 212 °F)\n• NoTC, can be selected to measure absolute conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity temperature coefficient*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00 %\/°C (EC and TDS only)\n(1.90 %\/°C default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS factor*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (0.50 default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (400) records organized in:\n• Manual log-on-demand, maximum 200 logs\n• Manual log-on-stability, maximum 200 logs\n• Interval logging*, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e* When operating in Standard Mode only!\n‡ Absolute conductivity (TDS) is the conductivity value without temperature compensation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600 - using the Dissolved Oxygen probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI764080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 ppm (mg\/L)\n0.0 to 300.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L)\n0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C * (−4.0 to 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\n(0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\n(0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 0% (HI7040) and 100% (water-saturated air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Pressure compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\n450.0 to 850.0 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Pressure compensation resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Salinity compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Salinity compensation resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records organized in:\n• Manual log-on-demand, maximum 200 logs\n• Manual log-on-stability, maximum 200 logs\n• Interval logging**, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e* Temperature limits will be reduced to actual probe limits.\n** When operating in Standard Mode only!\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Type C (5 VDC; 500 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F)\nMaximum 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.85 kg (1.87 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.documentation.hannainst.com\/manuals\/HI2600\"\u003epH and EC\/TDS and DO Starter Benchtop Meter - HI2600\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI2600-01 pH, EC, and DO Benchtop Meter (115V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI11310 pH digital electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI764026 electrode holder with the following accessories:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- base plate with integrated pivot pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- cable holder clip, attache\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• pH calibration kit:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 4 buffer solution (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 7 buffer solution (4 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 10 buffer solution sachets (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Electrode cleaning solution (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI920018 1.5 m USB-C to USB-C cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• USB-C power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Instrument quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Probe \/ electrode quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Battery safety insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461376369,"sku":"HI2600","price":66656.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI2600_Right-2__45600.jpg?v=1792646978"},{"product_id":"edge-multiparameter-ph-meter-230v-hi2020","title":"edge® Multiparameter pH Meter, 230V - HI2020-02","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eedge® is packed with many cutting edge features to ensure accuracy and usability.\u003c\/p\u003e\n\u003ch5\u003eDigital Electrodes\u003c\/h5\u003e\n\u003cp\u003eedge electrodes are highly advanced, featuring a built-in microchip that stores calibration information that is automatically retrieved by edge once the electrode is plugged in. These digital electrodes also feature an easy to plug in 3.5 mm connector so you never have to worry about the right angle or aligning pins.\u003c\/p\u003e\n\u003ch5\u003eSensor Check\u003c\/h5\u003e\n\u003cp\u003eWhen used with Hanna’s pH electrodes equipped with a matching pin, edge constantly checks the impedance of the pH measuring electrode to notify you in real time in the event of glass breakage. During calibration, Sensor Check checks the state of the junction. The reference junction is also evaluated and reported on the display.\u003c\/p\u003e\n\u003ch5\u003e3.5 mm Probe Input\u003c\/h5\u003e\n\u003cp\u003ePlugging an electrode in has never been simpler; no alignments, no broken pins, just connect the 3.5 mm plug and get started.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly versatile. It can be used in a variety of ways and in a variety of environments without taking up the space of a traditional benchtop meter.\u003c\/p\u003e\n\u003ch5\u003eWall Mount\u003c\/h5\u003e\n\u003cp\u003eUsing the wall mount cradle (included), edge can be placed on a wall, leaving zero footprint on the benchtop space. The cradle has a built-in connector to power edge and charge its batteries. edge's zero footprint is designed to save you valuable benchtop space.\u003c\/p\u003e\n\u003ch5\u003eCradle and Electrode Holder\u003c\/h5\u003e\n\u003cp\u003eedge is equipped with a benchtop cradle with an adjustable swivel electrode holder to charge and hold the edge securely in place at the optimum viewing angle.\u003c\/p\u003e\n\u003cp\u003eedge® is incredibly thin and weighs only 8.8 oz., has an 8 hour battery life, and dual USB inputs.\u003c\/p\u003e\n\u003ch5\u003eTwo USB Ports\u003c\/h5\u003e\n\u003cp\u003eedge includes one standard USB for exporting data with a flash drive and a second micro USB port for you to connect to a computer for file export and for charging your edge when the cradle is not available.\u003c\/p\u003e\n\u003ch5\u003eData Logging\u003c\/h5\u003e\n\u003cp\u003eedge allows you to store up to 1000 log records of data. Data sets include readings, GLP data, date and time.\u003c\/p\u003e\n\u003ch5\u003eTwo Operating Modes\u003c\/h5\u003e\n\u003cp\u003eedge can be used in Extended or Basic Operating Modes. Extended Mode enables all features available while the Basic Mode reduces the amount of features to a very simple operation. For example, in extended mode edge offers 5 point calibration with 2 custom buffers while in basic mode calibration can only be performed to 3 points with 5 preprogrammed buffers.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/45ms0xpvk5?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/8c55539d67ea1d24de589d4f7ab0d40faf95a394.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI2020-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e® Multiparameter pH Meter - HI2020\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.000 to 16.000 pH, -2.00 to 16.00 pH, ±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 pH, 0.01 pH, 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.002 pH, ±0.01 pH, ±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e5 points (Standard mode) 1.68, 4.01 (3.00†), 6.86, 7.01, 9.18, 10.01, 12.45, and two custom buffers; 3 points (Basic mode) 4.01; 6.86; 7.01; 9.18; 10.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC: -5.0 to 100.0ºC; 23.0 to 212.0°F*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eGlass and reference junction diagnostics ( HI 11311 \u0026amp; HI 12301 only), out of calibration range , probe condition, response time\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 µS\/cm, 30.0 to 299.9 µS\/cm, 300 to 2999 µS\/cm, 3.00 to 29.99 mS\/cm, 30.0 to 200.0 mS\/cm, up to 500.0 mS\/cm (absolute EC)**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 µS\/cm, 0.1 µS\/cm, 1 µS\/cm, 0.01 mS\/cm, 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.05 µS\/cm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point offset calibration (0.00 µS\/cm in air), 1 point slope calibration in EC standard 84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm and 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 ppm (mg\/L), 15.0 to 149.9 ppm (mg\/L), 150 to 1499 ppm (mg\/L), 1.50 to 14.99 g\/L, 15.0 to 100.0 g\/L, up to 400.0 g\/L (absolute TDS)**, with 0.80 conversion factor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1 ppm, 1 ppm, 0.01 g\/L, 0.1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC (0.0 to 100.0ºC; 32.0 to 212.0 °F), NoTC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0% NaCl***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1% NaCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (% NaCl) Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point with HI 7037L 100% NaCl sea water standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e2.00 to 42.00 PSU***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 80.0 g\/L***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution (ppt)\u003c\/td\u003e\n\u003ctd\u003e0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy (ppt)\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration (ppt)\u003c\/td\u003e\n\u003ctd\u003ethrough EC calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 ppm (mg\/L), 0.0 up to 300.0% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm, 0.1% saturation\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 digit, ±1.5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eone or two points at 0% (HI 7040 solution) and 100% (in air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eATC: 0 to 50 ºC; 32.0 to 122.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L (with 1 g\/L resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAltitude Compensation\u003c\/td\u003e\n\u003ctd\u003e-500 to 4000 m (with 100 m resolution)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 ºC, -4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C, 0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C, ±0.9 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI11310 pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eManual log-on-demand (Max. 200 logs); Manual log-on-stability (Max. 200 logs); Interval logging *** (Max. 600 samples; 100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003eup to 1000*** records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1 micro USB port for charging and PC connectivity, 1 USB port for storage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003eBuilt-in rechargeable battery with up to 8 hours of continuous use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e202 x 140 x 12.7mm (8” x 5.5” x 0.5”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e250 g (8.82 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI2020 pH kit includes: HI11310 glass body, refillable pH electrode with temperature sensor, pH 4 buffer solution sachets, pH 7 buffer solution sachets, pH 10 buffer solution sachets, electrode cleaning solution sachets,USB cable, benchtop docking station with electrode holder, wall mount cradle, 5 VDC power adapter, instruction manual, and quality certificate.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI2020-01\" target=\"_blank\" rel=\"noopener\"\u003e® Multiparameter pH Meter - HI2020\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461736817,"sku":"HI2020-02","price":69984.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sides-png-700_C3_97700.png?v=1792646983"},{"product_id":"ph-and-orp-starter-benchtop-meter-hi2620-and-hi2621","title":"pH and ORP Starter Benchtop Meter - HI2620 and HI2621 - HI262X","description":"\u003cstyle\u003e\n  .hanna-product-description h2 {\n    font-size: 28px;\n    line-height: 1.3;\n    margin: 40px 0 20px;\n    color: #222;\n  }\n\n  .hanna-subheading {\n    font-size: 21px;\n    line-height: 1.4;\n    font-weight: 600;\n    margin: 25px 0 12px;\n    color: #222;\n  }\n\n  .hanna-product-description p {\n    margin: 0 0 18px;\n  }\n\n  .hanna-product-description ul {\n    margin: 0 0 25px;\n    padding-left: 25px;\n  }\n\n  .hanna-product-description li {\n    margin-bottom: 10px;\n  }\n\n  .hanna-intro {\n    margin-bottom: 35px;\n  }\n\n  .hanna-highlight-box {\n    background: #f5f7f8;\n    border-left: 4px solid #0076a8;\n    padding: 25px;\n    margin: 25px 0;\n  }\n\n  .hanna-feature {\n    margin-bottom: 30px;\n  }\n\n  .hanna-model-grid {\n    display: grid;\n    grid-template-columns: repeat(2, 1fr);\n    gap: 20px;\n    margin: 25px 0 40px;\n  }\n\n  .hanna-model-box {\n    border: 1px solid #ddd;\n    padding: 25px;\n    background: #fafafa;\n  }\n\n  .hanna-model-box.hi2621 {\n    border-left: 4px solid #0076a8;\n  }\n\n  .hanna-comparison,\n  .hanna-specs {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0 40px;\n    font-size: 14px;\n  }\n\n  .hanna-comparison th,\n  .hanna-comparison td,\n  .hanna-specs th,\n  .hanna-specs td {\n    border: 1px solid #ddd;\n    padding: 12px 15px;\n    text-align: left;\n    vertical-align: top;\n  }\n\n  .hanna-comparison th,\n  .hanna-specs th {\n    background: #f2f2f2;\n    font-weight: 700;\n  }\n\n  .hanna-specs th {\n    width: 35%;\n  }\n\n  .hanna-included {\n    background: #fafafa;\n    padding: 25px;\n    border: 1px solid #ddd;\n    margin: 25px 0 40px;\n  }\n\n  .hanna-note {\n    font-size: 13px;\n    color: #666;\n  }\n\n  @media (max-width: 768px) {\n\n    .hanna-product-description h2 {\n      font-size: 24px;\n    }\n\n    .hanna-subheading {\n      font-size: 19px;\n    }\n\n    .hanna-model-grid {\n      grid-template-columns: 1fr;\n    }\n\n    .hanna-comparison,\n    .hanna-specs {\n      font-size: 13px;\n    }\n\n    .hanna-comparison th,\n    .hanna-comparison td,\n    .hanna-specs th,\n    .hanna-specs td {\n      padding: 9px;\n    }\n  }\n\n  @media (max-width: 480px) {\n\n    .hanna-comparison,\n    .hanna-specs {\n      display: block;\n      overflow-x: auto;\n      white-space: nowrap;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hanna-product-description\"\u003e\n\u003c!-- PRODUCT OPTIONS --\u003e\n\u003ch2\u003epH and ORP Benchtop Meter Options\u003c\/h2\u003e\n\u003cdiv class=\"hanna-model-grid\"\u003e\n\u003cdiv class=\"hanna-model-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI2620 Features\u003c\/div\u003e\n\u003cdiv class=\"hanna-subheading\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2620-overhead-button-press-1024x1024_622a8a6b-3e07-4e58-8f31-ac744df81e93.jpg?v=1789969710\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003epH Resolution:\u003c\/strong\u003e 0.01 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Points:\u003c\/strong\u003e Up to 3\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Logging:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePC\/USB Data Export:\u003c\/strong\u003e No\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Mode (Full Features):\u003c\/strong\u003e No\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-model-box hi2621\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI2621 Features\u003c\/div\u003e\n\u003cdiv class=\"hanna-subheading\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2620-overhead-button-press-1024x1024_622a8a6b-3e07-4e58-8f31-ac744df81e93.jpg?v=1789969710\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003epH Resolution:\u003c\/strong\u003e 0.01 \/ 0.001 pH\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eCalibration Points:\u003c\/strong\u003e Up to 5\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eData Logging:\u003c\/strong\u003e Yes – up to 1000 logs\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003ePC\/USB Data Export:\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eStandard Mode (Full Features):\u003c\/strong\u003e Yes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- BENCHTOP METER --\u003e\n\u003ch2\u003eThe Benchtop Meter for Every Lab Setting\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2620-overhead-button-press-1024x1024_622a8a6b-3e07-4e58-8f31-ac744df81e93.jpg?v=1789969710\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eWith a color LCD display, capacitive touch keypad, and clear on-screen text guides, users can easily set up, calibrate, and measure quickly.\u003c\/p\u003e\n\u003cp\u003eOur Simple Benchtop Meters are designed for both experienced professionals and those who prefer a straightforward, streamlined workflow.\u003c\/p\u003e\n\u003c!-- DIGITAL ELECTRODES --\u003e\n\u003ch2\u003eDigital Smart Electrodes for Enhanced Measurements\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2621-probe-closeup-1024x1024_c0a0f09a-3e6c-40ef-9c8a-8ee76721c5de.jpg?v=1789969764\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cp\u003eOur Simple Benchtop Meters (HI2620 and HI2621) measure pH and ORP with the supplied HI11310 Digital Smart pH Electrode.\u003c\/p\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eAdvantages of the pH Digital Electrode\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eDesigned for various industries and applications, this probe is durable and suitable for use in chemical analysis.\u003c\/li\u003e\n\u003cli\u003eCollect stable readings even in electrically noisy environments and eliminate drift with automatic noise filtering and digital processing.\u003c\/li\u003e\n\u003cli\u003eThe built-in temperature sensor ensures optimal temperature compensation. There is no need to manage an additional temperature probe.\u003c\/li\u003e\n\u003cli\u003eChange electrodes easily without recalibrating. All data from the last calibration is stored in the electrode for faster setup and less maintenance when switching electrodes.\u003c\/li\u003e\n\u003cli\u003eGain traceability with automatic sensor recognition and a unique serial ID number for each Digital Electrode.\u003c\/li\u003e\n\u003cli\u003eBe proactive and know the health of your pH electrode with Sensor Check™. Predictive maintenance alerts notify you when to clean, recalibrate, or replace your pH electrode before it fails.\u003c\/li\u003e\n\u003cli\u003eEquipped with a modern 3.5 mm connector that is sealed to protect against moisture and corrosion.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c!-- COMPATIBLE ELECTRODES --\u003e\n\u003ch2\u003eCompatible Electrodes\u003c\/h2\u003e\n\u003cdiv class=\"hanna-model-grid\"\u003e\n\u003cdiv class=\"hanna-model-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI10430\u003c\/div\u003e\n\u003cp\u003eDigital glass body pH electrode for hydrocarbons and solvents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-model-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI10530\u003c\/div\u003e\n\u003cp\u003eDigital glass body pH electrode for semi-solids and emulsions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-model-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI11310\u003c\/div\u003e\n\u003cp\u003eDigital glass body pH electrode for general-purpose applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-model-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI12300\u003c\/div\u003e\n\u003cp\u003eDigital PEI body pH electrode for field applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-model-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI12301\u003c\/div\u003e\n\u003cp\u003eDigital PEI body pH electrode with matching pin for field applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-model-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eHI36180\u003c\/div\u003e\n\u003cp\u003eDigital glass body ORP electrode for general-purpose applications.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- WHAT'S INCLUDED --\u003e\n\u003ch2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/b08eeee7-571e-4177-93ca-489c6162b6e7-1024x561_1f040d73-cf8e-461a-9a10-68071990062e.jpg?v=1789969813\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cdiv class=\"hanna-included\"\u003e\n\u003cul\u003e\n\u003cli\u003eHI11310 pH Digital Electrode\u003c\/li\u003e\n\u003cli\u003epH calibration kit:\n\u003cul\u003e\n\u003cli\u003epH 4 buffer solution – 2 sachets\u003c\/li\u003e\n\u003cli\u003epH 7 buffer solution – 4 sachets\u003c\/li\u003e\n\u003cli\u003epH 10 buffer solution – 2 sachets\u003c\/li\u003e\n\u003cli\u003eElectrode cleaning solution – 2 sachets\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003eHI764026 electrode holder with accessories\u003c\/li\u003e\n\u003cli\u003eHI920018 1.5 m USB-C to USB-C cable\u003c\/li\u003e\n\u003cli\u003eUSB-C power adapter\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate\u003c\/li\u003e\n\u003cli\u003eElectrode quality certificate\u003c\/li\u003e\n\u003cli\u003eBattery safety insert\u003c\/li\u003e\n\u003cli\u003eQuick reference guide with QR code for instruction manual download\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"hanna-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eModels\u003c\/th\u003e\n\u003ctd\u003eHI2620 and HI2621 using pH electrode HI11310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Range\u003c\/th\u003e\n\u003ctd\u003e−2.00 to 16.00 pH\u003cbr\u003e−2.000 to 16.000 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Resolution\u003c\/th\u003e\n\u003ctd\u003e0.01 pH\u003cbr\u003e0.001 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Accuracy at 25 °C \/ 77 °F\u003c\/th\u003e\n\u003ctd\u003e±0.01 pH\u003cbr\u003e±0.002 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Range\u003c\/th\u003e\n\u003ctd\u003e±1000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Accuracy at 25 °C \/ 77 °F\u003c\/th\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range – HI11310\u003c\/th\u003e\n\u003ctd\u003e−20.0 to 120.0 °C**\u003cbr\u003e−4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Resolution – HI11310\u003c\/th\u003e\n\u003ctd\u003e0.1 °C\u003cbr\u003e0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Accuracy at 25 °C \/ 77 °F – HI11310\u003c\/th\u003e\n\u003ctd\u003e±0.5 °C\u003cbr\u003e±0.9 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Calibration\u003c\/th\u003e\n\u003ctd\u003eAutomatic, up to three (five*) points. \u003cbr\u003e\u003cbr\u003eOption to select from standard buffers: pH 1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45* and two custom buffers*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eORP Electrode\u003c\/th\u003e\n\u003ctd\u003eHI36180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eORP Range\u003c\/th\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eORP Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eORP Accuracy at 25 °C \/ 77 °F\u003c\/th\u003e\n\u003ctd\u003e±0.2 mV (±999.9 mV)\u003cbr\u003e±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range – HI36180\u003c\/th\u003e\n\u003ctd\u003e−20.0 to 120.0 °C**\u003cbr\u003e−4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Resolution – HI36180\u003c\/th\u003e\n\u003ctd\u003e0.1 °C\u003cbr\u003e0.1 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Accuracy at 25 °C \/ 77 °F – HI36180\u003c\/th\u003e\n\u003ctd\u003e±0.5 °C\u003cbr\u003e±0.9 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eORP Calibration\u003c\/th\u003e\n\u003ctd\u003eSingle point offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Compensation\u003c\/th\u003e\n\u003ctd\u003eAutomatic, using integral temperature sensor \u003cbr\u003e−5.0 to 100.0 °C (23.0 to 212.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eLogging – HI2621 Only\u003c\/th\u003e\n\u003ctd\u003eUp to 1000* records organized in: \u003cbr\u003e\u003cbr\u003eManual log-on-demand – maximum 200 logs \u003cbr\u003eManual log-on-stability – maximum 200 logs \u003cbr\u003eInterval logging*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePC Interface – HI2621 Only\u003c\/th\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003eUSB Type-C \u003cbr\u003e5 VDC; 500 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnvironment\u003c\/th\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F) \u003cbr\u003eMaximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e205 × 160 × 77 mm \u003cbr\u003e(8.0 × 6.2 × 3.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 0.85 kg (1.87 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- NOTES --\u003e\n\u003cp class=\"hanna-note\"\u003e* When operating in Standard Mode in HI2621 only.\u003c\/p\u003e\n\u003cp class=\"hanna-note\"\u003e** Temperature limits will be reduced to actual probe limits.\u003c\/p\u003e\n\u003c!-- FINAL SUMMARY --\u003e\n\u003cdiv class=\"hanna-highlight-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003epH and ORP Starter Benchtop Meter – HI2620 and HI2621\u003c\/div\u003e\n\u003cp\u003eThe HI2620 and HI2621 provide fast and accurate pH and ORP measurements using Hanna Instruments digital smart electrodes. Automatic sensor recognition, integrated temperature measurement, calibration capabilities and a simple user interface make these meters suitable for routine laboratory measurements.\u003c\/p\u003e\n\u003cp\u003eThe HI2621 additionally provides data logging, Standard Mode and USB-C data transfer, making it suitable for applications requiring stored and transferable measurement records.\u003c\/p\u003e\n\u003cp\u003e\u003cspan style=\"text-decoration: underline;\"\u003e\u003ca href=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/MAN2621_12_25.pdf?v=1789969888\" rel=\"noopener\" target=\"_blank\"\u003eDownload Product manual\u003c\/a\u003e\u003c\/span\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003cthead style=\"color: #292f36;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"font-weight: bold;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2620 and HI2621\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eusing pH electrode HI11310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−2.00 to 16.00 pH\n−2.000 to 16.000 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\n0.001 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\n±0.002 pH*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C **\n(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C; (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to three (five*)\npoints Option to select from five (seven*) standard buffers: pH 1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45* and two custom buffers*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2620 and HI2621 - using ORP electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI36180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±999.9 mV)\n±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C**(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, using integral temperature sensor\n−5.0 to 100.0 °C (23.0 to 212.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging (HI2621 only)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* records organized in:\n• Manual log-on-demand, maximum 200 logs\n• Manual log-on-stability, maximum 200 logs\n• Interval logging*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e*When operating in Standard Mode in HI2621 only!\n** Temperature limits will be reduced to actual probe limits.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC interface (HI2621 only)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Type C (5 VDC; 500 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F)\nMaximum 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.85 kg (1.87 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003ca href=\"https:\/\/pages.hannainst.com\/hubfs\/product-manuals\/MAN2621_12_25.pdf?__hstc=4846506.db651f5a07b58c15f7cab8e1d9887c25.1743682097244.1756189614603.1756200365920.53\u0026amp;__hssc=4846506.5.1770802556815\u0026amp;__hsfp=53bb54f525dbdc401559d6b2d07a1118\"\u003epH and ORP Starter Benchtop Meter\u003c\/a\u003e\n\u003ch3\u003eOrdering Info \u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003epH and ORP Starter Benchtop Meter (HI2620\/HI2621)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI11310 pH digital electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• pH calibration kit:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 4 buffer solution (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 7 buffer solution (4 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 10 buffer solution sachets (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- Electrode cleaning solution (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI764026 electrode holder with the following accessories:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI920018 1.5 m USB-C to USB-C cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• USB-C power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Instrument quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Electrode quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Battery safety insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461900657,"sku":"HI262X","price":85849.88,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI2621_Right-1__06692.jpg?v=1792646986"}],"url":"https:\/\/hannainst.in\/collections\/ph-orp-benchtop-meters.oembed","provider":"hanna","version":"1.0","type":"link"}