{"title":"Reagents – Photometer Reagents","description":"","products":[{"product_id":"iron-reagent-set-for-wine-hi83741-20","title":"Iron Reagent Set for Wine - HI83741-20","description":"\u003cp\u003eThe HI83741-20 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow a method in which the reaction between iron and reagents causes a purple tint in the sample. By simply following the procedure and adding the correct amount of wine solvent 1,  and 1 packet each of HI83741A-0 and HI83741B-0 from the reagent set to the sample,  the reaction between iron and reagents causes a purple tint in the sample. The intensity of color is determined by the compatible HI83741 photometer and the concentration will be displayed. The results will be displayed in ppm (mg\/L) of iron. These reagents are designed to be used with samples that have an expected range of 0.0 to 15.0 ppm iron.\u003c\/p\u003e\n\u003cp\u003eTrace iron concentrations in wine are beneficial for enzyme activity,  as stabilizer,  and as a functional component for proteins. At higher concentrations it alters the redox potential,  in favouring oxidation,  affecting sensory characteristics and participating in the formation of complexes with tannin and phosphates resulting in instabilities (casse). The most common iron casse is 'white casse' (iron phosphate),  it is initially seen as milky white cloud and later as a precipitate. The 'blue casse' (ferric tannate) that occurs less often can be observed in white wines for example after tannic acid additions.Most of the iron present in wine is present in the ferrous Fe(II) state. The ratio of the Fe(II)\/Fe(III) depends on the oxidation state of the wine. If Fe(III) is formed,  it can bind with phosphates that are normally present in wine.Since iron strongly binds with several organic acids,  some wine makers add citric acid to the wine to complex free iron if the concentration exceeds 5 mg\/L. If no contamination occurs the normal iron concentrations in must range from 1 to 5 ppm. The most important source of iron in wine is contact with iron containing alloys during processing. During fermentation a part of the iron is absorbed by yeast and thus removed from the wine during filtration.\u003c\/p\u003e\n\u003cp\u003eCasse formation depends on: iron concentration,  pH,  ORP,  phosphate,  content and the type of wine.\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"500\"\u003e\n\u003ccol width=\"400\"\u003e\n\u003c\/colgroup\u003e\n\t\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003ewhite casse formation\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e\u003cstrong\u003ewhite casse inhibition\u003c\/strong\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eiron concentration \u0026gt; 7 ppm\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e iron concentration \u0026lt; 5 ppm\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003ehigh redox potential (Fe3+ present)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eclarification with bentonite\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003epH 2.9-3.6\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003ecitric acid addition 12-24 g\/hL\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI83741-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Iron Reagent Set for Wine - HI83741-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets and bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 20 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e The reaction between Iron and the reagents causes a purple tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI83741-20\"\u003eIron Reagent Set for Wine - HI83741-20\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871415927153,"sku":"HI83741-20","price":7025.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83741-20.jpg?v=1792646556"},{"product_id":"color-reagent-wine-solvent-1-hi83742-25","title":"Color Reagent Wine Solvent 1 - HI83742-25","description":"\u003cp\u003eThe HI83742-25 is a high quality reagent that is pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. This reagent allow for a direct reading of the sample. These reagents are designed to be used with samples that have an expected range of 0.00 to 9.99 for color hue and 0.00 to 15.00 for color density.\u003c\/p\u003e\n\u003cp\u003eAnalytical techniques have become a valuable tool of modern wine makers. Especially the definition and the processing techniques to obtain the desired wine color are of key importance. The right decisions taken during maturation of the grapes,  processing,  aging and blending,  all strongly influence the final result of wine color. The color of wine is always read after removal of suspended matter. There are mainly two color components present,  yellow and red but also a blue or green hue may appear. The color hue is the ratio between the yellow color concentrations over the red one,  and is an indication about the degree of evolution. The yellow color in wine comes from the presence of tannins (polymers of flavonoid -procyanidins type,  and non-flavonoid phenols) and can be read without dilution. The increase of the yellow-brown color in older wines is due to aging or oxidation. The red colors of wines are caused by free anthocyanins,  co-pigments of anthocyanins,  and polymerized phenolic compounds. The color of these pigments is pH dependent and can be intense dark. It is therefore necessary to dilute the wine sample taking care not to change the original wine pH. Hanna recommends using the special wine solvent to minimize possible errors due to dilution.Wine Solvent 1 is used to measure the true color of red wines and the results obtained conform to EC Directive 2676\/90.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI83742-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Color Reagent Wine Solvent 1 - HI83742-25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 20 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Direct reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI83742-25\"\u003eColor Reagent Wine Solvent 1 - HI83742-25\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871415959921,"sku":"HI83742-25","price":6319.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83742-25.jpg?v=1792646556"},{"product_id":"reducing-sugar-analysis-reagents-kit-20-tests-hi83746-20","title":"Reducing Sugar Analysis Reagents Kit (20 tests) - HI83746-20","description":"\u003cp\u003eThe HI83746-20 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Fehling method in which the reaction between reducing sugars and the two reagents (Fehling’s A Solution and Fehling’s B Solution) causes a blue tint in the sample. By adding a sample of wine that contains reducing sugars to the HI83746A-0 and HI83746B-0 reagents and digesting for 7 minutes,  a reaction will take place and the HI83746 photometer can be used to determine the reducing sugar concentration from the color that is produced. The results will be displayed in g\/L (ppt),  and users can perform simple calculations to obtain results of reducing sugar percent (%) or potential alcohol degree (% by volume). These reagents are designed to be used with samples that have an expected range of 0.00 to 50.00 g\/L (ppt) reducing sugars.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI83746-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Reducing Sugar Analysis Reagents Kit (20 tests) - HI83746-20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Vials\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 20\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Fehling Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI83746-20\"\u003eReducing Sugar Analysis Reagents Kit (20 tests) - HI83746-20\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871416058225,"sku":"HI83746-20","price":6319.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83746-20_1.jpg?v=1792646558"},{"product_id":"ammonia-low-range-reagents-100-tests-hi93700-01","title":"Ammonia Low Range Reagents (100 tests) - HI93700-01","description":"\u003cp\u003eThe HI93700-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Nessler Method in which the reaction between ammonia and reagents causes a yellow tint in the sample. By simply adding 4 drops from each bottle of HI93700-01 reagent set to the sample,  the reaction between ammonia and reagents causes a yellow tint in the sample will take place. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in ppm (mg\/L) of either ammonia-nitrogen (NH\u003csub\u003e3\u003c\/sub\u003e-N),  ammonia or ammonium based on meter and setting being used. These reagents are designed to be used with samples that have an expected range of 0.00 to 3.00 ppm ammonia-nitrogen.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93700-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia Low Range Reagents (100 tests) - HI93700-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles “A” and “B”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e adaptation of the ASTM Manual of Water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93700-01\"\u003eAmmonia Low Range Reagents (100 tests) - HI93700-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871424250225,"sku":"HI93700-01","price":6659.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93700-01.jpg?v=1792646625"},{"product_id":"ammonia-low-range-reagents-300-tests-hi93700-03","title":"Ammonia Low Range Reagents (300 tests) - HI93700-03","description":"\u003cp\u003eThe HI93700-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Nessler Method in which the reaction between ammonia and reagents causes a yellow tint in the sample. By simply adding 4 drops from each bottle of HI93700-03 reagent set to the sample, the reaction between ammonia and reagents causes a yellow tint in the sample will take place. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in ppm (mg\/L) of either ammonia-nitrogen (NH\u003csub\u003e3\u003c\/sub\u003e-N), ammonia or ammonium based on meter and setting being used. These reagents are designed to be used with samples that have an expected range of 0.00 to 3.00 ppm ammonia-nitrogen.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI93700-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAmmonia Low Range Reagents (300 tests) - HI93700-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eDropper bottles “A” and “B”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eadaptation of the ASTM Manual of Water and Environmental Technology D1426-93, Nessler Method. The reaction between ammonia and reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI93700-03\" target=\"_blank\" rel=\"noopener\"\u003eAmmonia Low Range Reagents (300 tests) - HI93700-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871424348529,"sku":"HI93700-03","price":19405.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93700-03.jpg?v=1792646625"},{"product_id":"free-chlorine-reagents-100-tests-hi93701-01","title":"Free Chlorine Reagents (100 tests) - HI93701-01","description":"\u003cp\u003eThe HI93701-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be display the concentration of chlorine in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L free chlorine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93701-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Free Chlorine Reagents (100 tests) - HI93701-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and the reagents causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93701-01\"\u003eFree Chlorine Reagents (100 tests) - HI93701-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871424741745,"sku":"HI93701-01","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93701-01.jpg?v=1792646626"},{"product_id":"free-chlorine-reagents-300-tests-hi93701-03","title":"Free Chlorine Reagents (300 tests) - HI93701-03","description":"\u003cp\u003eThe HI93701-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. By simply adding the packet of HI93701-03 reagent to the sample,  the reaction will take place and one of Hanna’s compatible benchtop or portable meter will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of free chlorine. These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L free chlorine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93701-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Free Chlorine Reagents (300 tests) - HI93701-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and the reagents causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93701-03\"\u003eFree Chlorine Reagents (300 tests) - HI93701-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871424774513,"sku":"HI93701-03","price":9038.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93701-01_1.jpg?v=1792646627"},{"product_id":"free-chlorine-liquid-reagents-300-tests-hi93701-f","title":"Free Chlorine Liquid Reagents (300 tests) - HI93701-F","description":"\u003cp\u003eThe HI93701-F are high quality liquid reagents that allow for users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. By simply adding the 3 drops of HI93701A-F and 3 drops of HI93701B-F reagents to the sample, the reaction will take place and one of Hanna’s compatible benchtop or portable meter will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of free chlorine. These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L free chlorine.\u003c\/p\u003e\n\u003ch5\u003eCompatible Photometers Include:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHI83099\u003c\/li\u003e\n\u003cli\u003eHI83200\u003c\/li\u003e\n\u003cli\u003eHI83203\u003c\/li\u003e\n\u003cli\u003eHI83205\u003c\/li\u003e\n\u003cli\u003eHI83206\u003c\/li\u003e\n\u003cli\u003eHI83208\u003c\/li\u003e\n\u003cli\u003eHI96724\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI93701-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFree Chlorine Liquid Reagents (300 tests) - HI93701-F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003eDropper Bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI93701-F\" target=\"_blank\" rel=\"noopener\"\u003eFree Chlorine Liquid Reagents (300 tests) - HI93701-F\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871424938353,"sku":"HI93701-F","price":3682.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93701-f.jpg?v=1792646627"},{"product_id":"total-chlorine-liquid-reagents-300-tests-hi93701-t","title":"Total Chlorine Liquid Reagents (300 tests) - HI93701-T","description":"\u003cp\u003eThe HI93701-T are high quality liquid reagents that allow for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The methods use a DPD reagent in which the reaction between chlorine and reagent causes a pink tint in the sample. By simply adding the 3 drops of HI93701A-T and 3 drops of HI93701B-T and 1 drop of HI93701C-T total chlorine can be measured. Additionally free chlorine can be measured by using 3 drops of HI93701A-T and 3 drops of HI93701B-T. By adding the reagents to the sample,  the reaction will take place and one of Hanna's compatible benchtop or portable photometers will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of free or total chlorine. These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L free or total chlorine.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCompatible Photometers Include:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHI83200\u003c\/li\u003e\n\u003cli\u003eHI83203\u003c\/li\u003e\n\u003cli\u003eHI83205\u003c\/li\u003e\n\u003cli\u003eHI83206\u003c\/li\u003e\n\u003cli\u003eHI83208\u003c\/li\u003e\n\u003cli\u003eHI83099\u003c\/li\u003e\n\u003cli\u003eHI96724\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93701-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Total Chlorine Liquid Reagents (300 tests) - HI93701-T\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper Bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests free or total chlorine\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93701-T\"\u003eTotal Chlorine Liquid Reagents (300 tests) - HI93701-T\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871425003889,"sku":"HI93701-T","price":5469.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93701-t.jpg?v=1792646629"},{"product_id":"copper-high-range-reagents-100-tests-hi93702-01","title":"Copper High Range Reagents (100 tests) - HI93702-01","description":"\u003cp\u003eThe HI93702-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the bicinchoninate method in which the reaction between copper and the reagent causes a color change in the sample. The intensity of color is determined by a compatible photometer and the copper concentration will be displayed in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L copper.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93702-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Copper High Range Reagents (100 tests) - HI93702-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of EPA approved bicinchoninate method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93702-01\"\u003eCopper High Range Reagents (100 tests) - HI93702-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871424971121,"sku":"HI93702-01","price":5129.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93702-01.jpg?v=1792646628"},{"product_id":"copper-high-range-reagents-300-tests-hi93702-03","title":"Copper High Range Reagents (300 tests) - HI93702-03","description":"\u003cp\u003eThe HI93702-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the bicinchoninate method in which the reaction between copper and the reagent causes a color change in the sample. The intensity of color is determined by a compatible photometer and the copper concentration will be displayed in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L copper.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93702-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Copper High Range Reagents (300 tests) - HI93702-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of EPA approved bicinchoninate method. The reaction between copper and the bicinchoninate reagent causes a purple tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93702-03\"\u003eCopper High Range Reagents (300 tests) - HI93702-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871425364337,"sku":"HI93702-03","price":14760.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93702-01_1.jpg?v=1792646629"},{"product_id":"0-ftu-turbidity-calibration-standard-hi93703-0","title":"0 FTU Turbidity Calibration Standard - HI93703-0","description":"\u003cp\u003eThe HI93703 ISO compliant turbidity meter is designed to be routinely standardized with a known light scattering standard. As with all analytical standards or reference materials,  a turbidity standard should be able to perform the following: provide traceability,  demonstrate the accuracy of results,  calibrate the equipment and methodology,  monitor user performance,  validate tests,  and facilitate comparability. Standardization ensures that when the correct procedures have been followed,  the same analysis of the same materials will produce results that agree with each other whenever they are performed.\u003c\/p\u003e\n\u003cp\u003eHanna turbidity standards are prepared from AMCO AEPA-1 materials that are known for being highly stable and reliable for standardization. AMCO AEPA-1 turbidity standards are a stabilized suspension of cross linked styrene divinylbenzene copolymer microbeads in ultrapure water. These beads are chemically inert and keep their chemical balance in a water medium regardless of concentration. Particle size,  uniform shape,  and refractive index make these spheres ideal to characterize light absorption and scatter for 90° behavior in the UV-VIS range. In addition,  the bead’s spherical shape and size helps prevent the accumulation or precipitation of the standard. For these reasons,  the AMCO AEPA-1 standards are very stable.\u003c\/p\u003e\n\u003cp\u003eThis standard is prepared and bottled in a clean room facility. It is tested and validated for accuracy and stability,  and certified as free from any toxic chemicals or compounds. All prepared standards are compared to formazin turbidity standard solutions. The values obtained and the date of analysis are reported on the supplied certifcate of analysis.\u003c\/p\u003e\n\u003cp\u003eHI93703-0 is a high quality turbidity calibration standard that allows users to validate and calibrate the HI93703 turbidity meter that has a 0 to 1000 FTU range. HI93703-0 includes one standard solution with an expected reading of 0 FTU. The calibration standard is produced in our state-of-the-art manufacturing facility using NIST traceable reference materials in a temperature controlled environment.\u003c\/p\u003e\n\u003ch5\u003eSupplied with Certificate of Analysis\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003cli\u003eStandard value\u003c\/li\u003e\n\u003cli\u003eReference meter NIST traceable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eProvided storage containers\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLight tight\u003c\/li\u003e\n\u003cli\u003eProtects from accidental breakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HI93703-0 turbidity calibration standard is made specifically for the HI93703 turbidity meter. The calibration process is quick and easy.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 0 FTU Turbidity Calibration Standard - HI93703-0\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Standard solution: 0 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1 bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-0\"\u003e0 FTU Turbidity Calibration Standard - HI93703-0\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871425397105,"sku":"HI93703-0","price":3203.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-0.jpg?v=1792646630"},{"product_id":"10-ftu-turbidity-calibration-standard-hi93703-10","title":"10 FTU Turbidity Calibration Standard - HI93703-10","description":"\u003cp\u003eThe HI93703 ISO compliant turbidity meter is designed to be routinely standardized with a known light scattering standard. As with all analytical standards or reference materials,  a turbidity standard should be able to perform the following: provide traceability,  demonstrate the accuracy of results,  calibrate the equipment and methodology,  monitor user performance,  validate tests,  and facilitate comparability. Standardization ensures that when the correct procedures have been followed,  the same analysis of the same materials will produce results that agree with each other whenever they are performed.\u003c\/p\u003e\n\u003cp\u003eHanna turbidity standards are prepared from AMCO AEPA-1 materials that are known for being highly stable and reliable for standardization. AMCO AEPA-1 turbidity standards are a stabilized suspension of cross linked styrene divinylbenzene copolymer microbeads in ultrapure water. These beads are chemically inert and keep their chemical balance in a water medium regardless of concentration. Particle size,  uniform shape,  and refractive index make these spheres ideal to characterize light absorption and scatter for 90° behavior in the UV-VIS range. In addition,  the bead’s spherical shape and size helps prevent the accumulation or precipitation of the standard. For these reasons,  the AMCO AEPA-1 standards are very stable.\u003c\/p\u003e\n\u003cp\u003eThis standard is prepared and bottled in a clean room facility. It is tested and validated for accuracy and stability,  and certified as free from any toxic chemicals or compounds. All prepared standards are compared to formazin turbidity standard solutions. The values obtained and the date of analysis are reported on the supplied certifcate of analysis.\u003c\/p\u003e\n\u003cp\u003eHI93703-10 is a high quality turbidity calibration standard that allows users to validate and calibrate the HI93703 turbidity meter that has a 0 to 1000 FTU range. HI93703-10 includes one standard solution with an expected reading of 10 FTU. The calibration standard is produced in our state-of-the-art manufacturing facility using NIST traceable reference materials in a temperature controlled environment.\u003c\/p\u003e\n\u003ch5\u003eSupplied with Certificate of Analysis\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003cli\u003eStandard value\u003c\/li\u003e\n\u003cli\u003eReference meter NIST traceable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eProvided storage containers\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLight tight\u003c\/li\u003e\n\u003cli\u003eProtects from accidental breakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe HI93703-10 turbidity calibration standard is made specifically for the HI93703 turbidity meter. The calibration process is quick and easy.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 10 FTU Turbidity Calibration Standard - HI93703-10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Standard solution: 10 FTU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1 bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-10\"\u003e10 FTU Turbidity Calibration Standard - HI93703-10\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871425429873,"sku":"HI93703-10","price":4563.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-10.jpg?v=1792646631"},{"product_id":"ozone-reagents-100-tests-hi93757-01","title":"Ozone Reagents (100 tests) - HI93757-01","description":"\u003cp\u003eThe HI93757-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow an adaptation of the Standard Methods for the Examination of Water and Wastewater,  20\u003csup\u003eth\u003c\/sup\u003e edition,  DPD method in which the reaction between ozone and reagent causes a pink tint in the sample. By simply adding the reagent to the sample,  a reaction will take place and a compatible benchtop meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of ozone. These reagents are designed to be used with samples that have an expected range of 0.00 to 2.00 mg\/L ozone.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93757-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ozone Reagents (100 tests) - HI93757-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, DPD method. The reaction between ozone and the reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93757-01\"\u003eOzone Reagents (100 tests) - HI93757-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871425462641,"sku":"HI93757-01","price":3682.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93757.jpg?v=1792646631"},{"product_id":"ozone-reagents-300-tests-hi93757-03","title":"Ozone Reagents (300 tests) - HI93757-03","description":"\u003cp\u003eThe HI93757-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow an adaptation of the Standard Methods for the Examination of Water and Wastewater,  20\u003csup\u003eth\u003c\/sup\u003e edition,  DPD method in which the reaction between ozone and reagent causes a pink tint in the sample. By simply adding the reagent to the sample,  a reaction will take place and a compatible benchtop meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of ozone. These reagents are designed to be used with samples that have an expected range of 0.00 to 2.00 mg\/L ozone.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93757-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ozone Reagents (300 tests) - HI93757-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, DPD method. The reaction between ozone and the reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93757-03\"\u003eOzone Reagents (300 tests) - HI93757-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871425823089,"sku":"HI93757-03","price":10707.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93757_1.jpg?v=1792646632"},{"product_id":"total-copper-high-range-reagents-100-tests-hi93702t-01","title":"Total Copper High Range Reagents (100 tests) - HI93702T-01","description":"\u003cp\u003eThe HI93702T-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow an adaptation of the Bicinchoninate Method in which the reaction between total copper and the reagent causes a color change in the sample. By simply adding the packet of HI93702T-01 reagent to the sample,  the reaction between copper and reagent causes a purple tint in the sample. The intensity of color is determined by the compatible HI96702 photometer and the concentration will be displayed. The results will be displayed in mg\/L (ppm) of total copper. These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L total copper.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93702T-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Total Copper High Range Reagents (100 tests) - HI93702T-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the bicinchoninate method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93702T-01\"\u003eTotal Copper High Range Reagents (100 tests) - HI93702T-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871425888625,"sku":"HI93702T-01","price":18329.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/total-copper-high-range-reagents-hi93702t-01.jpg?v=1792646633"},{"product_id":"total-copper-high-range-reagents-300-tests-hi93702t-03","title":"Total Copper High Range Reagents (300 tests) - HI93702T-03","description":"\u003cp\u003eThe HI93702T-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the Bicinchoninate Method in which the reaction between total copper and the reagent causes a color change in the sample. By simply adding the packet of HI93702T-03 reagent to the sample,  the reaction between copper and reagent causes a purple tint in the sample. The intensity of color is determined by the compatible HI96702 photometer and the concentration will be displayed. The results will be displayed in mg\/L (ppm) of total copper. These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L total copper.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93702T-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Total Copper High Range Reagents (300 tests) - HI93702T-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the bicinchoninate method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93702T-03\"\u003eTotal Copper High Range Reagents (300 tests) - HI93702T-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871426347377,"sku":"HI93702T-03","price":54132.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/total-copper-high-range-reagents-hi93702t-01_1.jpg?v=1792646635"},{"product_id":"hi93703-portable-turbidity-meter-iso-compliant-kit-hi93703-11","title":"HI93703 Portable Turbidity Meter ISO Compliant-kit - HI93703-11","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2016-04-27_at_1.48.28_PM.png\" alt=\"turbidity measurement\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe HI93703 Portable Turbidity Meter is specially designed for water quality measurements,  providing reliable and accurate readings,  even within low turbidity ranges. The instrument is based on a state-of-the-art optical system which guarantees accurate results,  assures long term stability,  and minimizes stray light and color interferences. Periodic calibration with the supplied standards compensates for any variations in intensity of the LED light source.  The 25 mm round cuvettes composed of special optical glass guarantee the repeatability of turbidity measurements.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eSingle Beam Design\u003c\/strong\u003e - The HI93703 measures turbidity using a light detector at 90° for detection of scattered light. Turbidity measurements can be made in the 0.00 to 1000 FTU range.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eISO Compliant\u003c\/strong\u003e -  The HI93703 meets and exceeds the requirements of ISO 7027 method for turbidity measurements by use of an infrared LED light source. As this meter has been designed to follow this ISO method,  the units are displayed in FTU (Formazine Turbidity Unit); FTU is equivalent to the other internationally recognized unit of NTU (Nephelometric Turbidity Unit).\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e – The HI93703 has a powerful calibration function that compensates for variation in light intensity. The calibration can be done using the supplied calibration solutions or user-prepared standards. A two or three-point turbidity calibration can be performed by using the supplied (0,  10,  and 500 FTU) standards.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAMCO AEPA-1 Primary Turbidity Standard\u003c\/strong\u003e - The AMCO AEPA-1 supplied standards are recognized as a primary standard by the USEPA. These non-toxic standards are made of styrene divinylbenzene polymer spheres that are uniform in size and density. The standards are reusable and stable with a long shelf life.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLast Calibration Date\u003c\/strong\u003e – The HI93703 allows the user to store the last calibration date. Recall of the last calibration date is simple with a press of the \"DATE\" button on the face of the meter.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLow Battery Indicator \u003c\/strong\u003e– A \"LO BAT\" indication will appear on the lower right corner of the display when the batteries are low and need to be replaced. At this point,  the instrument can still perform approximately 50 measurements. When the battery is too low to perform reliable measurements,  a message appears and the meter will automatically switch off.\u003c\/p\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eTurbidity is one of the most important parameters used to determine the quality of drinking water. Once considered as a mostly aesthetic characteristic of drinking water,  significant evidence exists that controlling turbidity is a competent safeguard against pathogens. In natural water,  turbidity measurements are taken to gauge general water quality and its compatibility in applications involving aquatic organisms. The monitoring and treatment or wastewater was once solely based on the control of turbidity. Currently,  the measurement of turbidity at the end of the wastewater treatment process is necessary to verify that the values are within regulatory standards.\u003c\/p\u003e\n\u003cp\u003eTurbidity of water is an optical property that causes light to be scattered and absorbed,  rather than transmitted. The scattering of light that passes through a liquid is primarily caused by the suspended solids present. The higher the turbidity,  the greater the amount of scattered light. Even a very pure liquid will scatter light to a certain degree,  as no solution will have zero turbidity.\u003c\/p\u003e\n\u003cp\u003eThe ISO standard for turbidity measurement uses infrared wavelength of light that is outside the visible spectrum. The primary benefit of the ISO method over the EPA method is the reduction of color interference. The EPA method uses a tungsten lamp that produces light that contains all of the visible wavelengths of light that we see as white. A solution that is colored will be adsorbed by a complementary wavelength of light which will affect the turbidity reading. Since the ISO method is outside the visible wavelength of light the color in the sample does not interfere with the measurement. The USEPA prefers the tungsten lamp since it provides for better accuracy at low ranges and drinking water should not be colored. The requirements of an optical turbidity meter for the measurement of diffuse radiation used in low range measurements (i.e. drinking water) expressed as formazin nephelometric units (FNU) according to ISO 7027:1999 are:\u003c\/p\u003e\n\u003ch5\u003eMeasurement of diffuse radiation for water with low turbidity (0 FNU to 40 FNU)\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eThe wavelength of the incident radiation shall be 860 nm.\u003c\/li\u003e\n\u003cli\u003eThe spectral bandwidth of the incident radiation shall be less than or equal to 60 nm.\u003c\/li\u003e\n\u003cli\u003eThere shall be no divergence from parallelism of the incident radiation and any convergence shall not exceed 1.5o.\u003c\/li\u003e\n\u003cli\u003eThe measuring angle,  theta,  between the optical axis of the incident radiation and that of the diffused radiation shall be 90o ±2.5o.\u003c\/li\u003e\n\u003cli\u003eThe aperture angle should be between 20o and 30o in the water sample.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eThe HI93703 meets and exceeds the meter criteria specified by ISO 7027.\u003c\/h5\u003e\n\u003ch2\u003ePrinciple of Operation\u003c\/h2\u003e\n\u003cp\u003eThe light beam that passes through the sample is scattered in all directions. The intensity and pattern of the scattered light is affected by many variables,  such as wavelength of the incident light,  particle size and shape,  refractive index,  and color. The optical system of the HI93703 includes a LED,  and a scattered light detector (90°).\u003c\/p\u003e\n\u003cp\u003eThe lower detection limit of a turbidimeter is determined by stray light that is detected by the sensors but not caused by light scattering from suspended particles. The optical system of the HI93703 is designed to have very low stray light,  providing highly accurate results for low turbidity samples.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI93703-In-Case_1200x1200_72_RGB.jpg\" alt=\"turbidity HI93703 kit\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eThe HI93703C is available as a kit. The kit includes:\u003c\/h5\u003e\n\u003cp\u003ePortable turbidity meter\u003cbr\u003e Sample cuvettes (2)\u003cbr\u003e Caps (2)\u003cbr\u003e Batteries (4 x 1.5V AA) and instructions\u003cbr\u003e HI93703-0 (0 FTU) \u0026amp; HI93703-10 (10 FTU) calibration solutions\u003cbr\u003e HI93703-50 cleaning solution\u003cbr\u003e Tissue for wiping cuvettes\u003cbr\u003e Rugged carrying case\u003c\/p\u003e\n\u003cp\u003eThe AMCO AEPA-1 standards for HI93703 ensure that measurements are traceable to a primary reference materials. These standards are used for calibration and performance verification of the turbidity meter.\u003c\/p\u003e\n\u003ch5\u003eSupplied with Certificate of Analysis\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003cli\u003eStandard value @ 25 ℃\u003c\/li\u003e\n\u003cli\u003eReference meter NIST traceable\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eProvided storage containers\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eLight tight\u003c\/li\u003e\n\u003cli\u003eProtects from accidental breakage\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI93703 Portable Turbidity Meter ISO Compliant-kit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 50.00 FTU\u003cbr\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\u003ctd\u003e50 to 1000 FTU\u003c\/td\u003e\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 (0.00 to 50.00 FTU); 1 (50 to 1000 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5 FTU or ±5% of reading (whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Calibration\u003c\/td\u003e\n\u003ctd\u003e three points (0 FTU, 10 FTU and 500 FTU)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Light Source\u003c\/td\u003e\n\u003ctd\u003e silicon photocell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Light Detector\u003c\/td\u003e\n\u003ctd\u003e infrared LED \/ life of instrument\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e log on demand\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e 199 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e RS232 using HI92000 software\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutomatic Shut-Off\u003c\/td\u003e\n\u003ctd\u003e auto-off after 5 minutes of non-use\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e 1.5V AA (4) \/approximately 60 hours of continuous use or 900 measurements\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% (non condensing)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 220 x 82 x 66 mm (8.7 x 3.2 x 2.6”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 510 g (1.1 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI93703 is supplied complete with glass cuvette, batteries and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-11\"\u003eHI93703 Portable Turbidity Meter ISO Compliant-kit\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871426412913,"sku":"HI93703-11","price":106703.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-front_1.jpg?v=1792646635"},{"product_id":"dispersing-agent-hi93703-51","title":"Dispersing Agent - HI93703-51","description":"\u003cp\u003eMaking sure that there is no turbidity present in a sample is important in colorimetric measurements. Turbidity can occur in samples as a result of chemical interactions in certain photometric methods. Turbidity interferes with the transmittance of light through the sample and can lead to inaccurate readings if not removed. The dispersing agent removes this turbidity allowing for accurate measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Dispersing Agent - HI93703-51\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1 dropper bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-51\"\u003eDispersing Agent - HI93703-51\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871426773361,"sku":"HI93703-51","price":1900.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-51.jpg?v=1792646636"},{"product_id":"glycine-powder-reagents-100-tests-hi93703-52","title":"Glycine Powder Reagents (100 tests) - HI93703-52","description":"\u003cp\u003eThe HI93703-52 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents are used to remove the chlorine interference which would also react with DPD causing a pink tint in the sample. By simply adding the reagent to the sample,  a reaction will take place to remove the interference. The HI93757-0 reagent for ozone is then added to the sample and the colorimetric analysis then performed. These reagents are optional and should only be used when chlorine is present in the sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Glycine Powder Reagents (100 tests) - HI93703-52\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-52\"\u003eGlycine Powder Reagents (100 tests) - HI93703-52\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871426806129,"sku":"HI93703-52","price":2436.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker-small-reagents_1_19.png?v=1792646637"},{"product_id":"chlorine-remover-reagent-hi93703-53","title":"Chlorine Remover Reagent - HI93703-53","description":"\u003cp\u003eThe HI93703-53 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents are used to remove the chlorine interference which would interfere with measuring the sample. To eliminate Cl\u003csub\u003e2\u003c\/sub\u003e interference add to the 10 mL unreacted sample,  1 drop of the HI93703-53 Chlorine Remover,  for each 2 mg\/L of chlorine.These reagents are optional and should only be used when chlorine is present in the sample.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Chlorine Remover Reagent - HI93703-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-53\"\u003eChlorine Remover Reagent - HI93703-53\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871426838897,"sku":"HI93703-53","price":3682.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-53.jpg?v=1792646637"},{"product_id":"activated-carbon-50-packets-hi93703-55","title":"Activated Carbon (50 packets) - HI93703-55","description":"\u003cp\u003eMaking sure that there is no color or turbidity is present in a sample is important in colorimetric measurements. Color and turbidity interfere with the transmittance of light through the sample and can lead to inaccurate readings if not removed. The activated carbon removes these interferences allowing for accurate measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Activated Carbon (50 packets) - HI93703-55\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 50 packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-55\"\u003eActivated Carbon (50 packets) - HI93703-55\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871426871665,"sku":"HI93703-55","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-55.jpg?v=1792646639"},{"product_id":"glycerol-standard-30-ml-x-4-for-honey-and-maple-syrup-photometers-hi93703-57","title":"Glycerol Standard (30 mL x 4) for Honey and Maple Syrup Photometers - HI93703-57","description":"\u003cp\u003eGlycerol is a simple organic alcohol compound that is clear,  colorless and viscous. Due to these properties it is used to calibrate a photometer to 100% transmittance which is the maximum amount of light that passes through a cuvette containing a sample and detected by a silicon photodetector. For honey and maple the calibration is done at a specific wavelength of light. The wavelength used is based on the appropriate method and represents a complementary color of the sample to be tested.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Glycerol Standard (30 mL x 4) for Honey and Maple Syrup Photometers - HI93703-57\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 4 bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 30 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-57\"\u003eGlycerol Standard (30 mL x 4) for Honey and Maple Syrup Photometers - HI93703-57\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871426969969,"sku":"HI93703-57","price":2807.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-57.jpg?v=1792646639"},{"product_id":"silicone-oil-15-ml-hi98703-58","title":"Silicone Oil (15 mL) - HI98703-58 - HI93703-58","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-06-01_at_10.36.42_AM.png\" alt=\"silicone oil\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe glass cuvette is an important component of the optical system in all colorimetric and turbidimetric measurements. Light reaches the sample by first passing through the cuvette glass. Based on the sample,  the light is absorbed,  transmitted,  or scattered. As a result,  the measurement can be affected if the cuvette glass has imperfections,  dirt,  dust,  scratches,  or fingerprints present.\u003c\/p\u003e\n\u003cp\u003eTo hide minor imperfections and scratches,  the outer surface of the cuvettes should be oiled with the HI98703-58 silicone oil. The silicone oil has the same refractive index as the glass and will not alter the turbidity readings. Applying silicone oil is very important,  especially for low turbidity samples (\u0026lt; 1 NTU),  as scratches and imperfections in the glass can alter turbidity readings. Simple apply a few drops of oil onto a clean,  dry cuvette and wipe thoroughly with a lint-free cloth. Wipe off the excess oil till you obtain a thin,  uniform layer and the cuvette appears nearly dry,  with no visible oil.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-58\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI98703-58 Silicone Oil (15 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 15 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-58\"\u003eHI98703-58 Silicone Oil (15 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427002737,"sku":"HI93703-58","price":2807.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/30ml_29_1.png?v=1792646641"},{"product_id":"activated-charcoal-10-g-hi93703-59","title":"Activated Charcoal (10 g) - HI93703-59","description":"\u003cp\u003ePrior to analysis,  red wine must be decolorized with activated charcoal. Phenols present in the wine are an interference in the Fehling reaction of reducing sugars. Through the use of several scoops of HI93703-59 activated charcoal and filter paper,  the phenols can be removed to ensure an accurate analysis of reducing sugar concentration.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93703-59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Activated Charcoal (10 g) - HI93703-59\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1 bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 10g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93703-59\"\u003eActivated Charcoal (10 g) - HI93703-59\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427035505,"sku":"HI93703-59","price":2807.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93703-59.jpg?v=1792646641"},{"product_id":"hydrazine-reagents-100-tests-hi93704-01","title":"Hydrazine Reagents (100 tests) - HI93704-01","description":"\u003cp\u003eThe HI93704-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the ASTM Manual of Water and Environmental Technology,  Method D1385-88 in which the reaction between hydrazine and p-dimethylaminobenzaldehyde reagent causes a yellow tint in the sample. By simply adding the reagent to the sample,  a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in µg\/L (ppb) of hydrazine. These reagents are designed to be used with samples that have an expected range of 0 to 400 µg\/L hydrazine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93704-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Hydrazine Reagents (100 tests) - HI93704-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper Bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88 for natural and treated water. The reaction between hydrazine and the liquid reagent causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93704-01\"\u003eHydrazine Reagents (100 tests) - HI93704-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427068273,"sku":"HI93704-01","price":2436.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/30ml_16.png?v=1792646641"},{"product_id":"hydrazine-reagents-300-tests-hi93704-03","title":"Hydrazine Reagents (300 tests) - HI93704-03","description":"\u003cp\u003eThe HI93704-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the ASTM Manual of Water and Environmental Technology,  Method D1385-88 in which the reaction between hydrazine and p-dimethylaminobenzaldehyde reagent causes a yellow tint in the sample. By simply adding the reagent to the sample,  a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in µg\/L (ppb) of hydrazine. These reagents are designed to be used with samples that have an expected range of 0 to 400 µg\/L hydrazine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93704-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Hydrazine Reagents (300 tests) - HI93704-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper Bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88 for natural and treated water. The reaction between hydrazine and the liquid reagent causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93704-03\"\u003eHydrazine Reagents (300 tests) - HI93704-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427264881,"sku":"HI93704-03","price":6772.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/30ml_24.png?v=1792646642"},{"product_id":"silica-low-range-reagents-100-tests-hi93705-01","title":"Silica Low Range Reagents (100 tests) - HI93705-01","description":"\u003cp\u003eThe HI93705-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the ASTM D859 Heteropoly Blue Method in which the reaction between silica and reagents causes a blue tint in the sample. By first adding 6 drops from the bottle of HI93705A reagent to the sample followed by the addition of two powder packets,  the reaction will take place and one of Hanna’s compatible benchtop or portable meters will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of silica. These reagents are designed to be used with samples that have an expected range of 0.00 to 2.00 mg\/L silica.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93705-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Silica Low Range Reagents (100 tests) - HI93705-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles and packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ASTM D859 method of heteropoly blue method. The reaction between silica and reagents causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93705-01\"\u003eSilica Low Range Reagents (100 tests) - HI93705-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427297649,"sku":"HI93705-01","price":6659.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/small-reagents_1_8_1_2_1_2_2_1_1.png?v=1792646643"},{"product_id":"silica-low-range-reagents-300-tests-hi93705-03","title":"Silica Low Range Reagents (300 tests) - HI93705-03","description":"\u003cp\u003eThe HI93705-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the ASTM D859 heteropoly blue method in which the reaction between Silica and the reagent causes a blue tint in the sample. By simply adding the reagents to the sample in the correct order,  the reaction will take place and one of Hanna’s compatible benchtop or portable meters will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of Silica. These reagents are designed to be used with samples that have an expected range of 0.00 to 2.00 mg\/L Silica.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93705-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Silica Low Range Reagents (300 tests) - HI93705-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles and packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ASTM D859 method of heteropoly blue method. The reaction between silica and reagents causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93705-03\"\u003eSilica Low Range Reagents (300 tests) - HI93705-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427330417,"sku":"HI93705-03","price":19148.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/small-reagents_1_8_1_1_1_1_2_1_1_1_1.png?v=1792646644"},{"product_id":"phosphorus-reagents-100-tests-hi93706-01","title":"Phosphorus Reagents (100 tests) - HI93706-01","description":"\u003cp\u003eThe HI93706-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater,  18\u003csup\u003eth\u003c\/sup\u003e edition,  Amino Acid method. The reaction between phosphate and reagents causes a blue tint in the sample. By simply adding the reagents to the sample,  a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of phosphorus (P). These reagents are designed to be used with samples that have an expected range of of 0.0 to 15.0 mg\/L phosphorus.\u003c\/p\u003e\n\u003cp\u003eThese reagents do not measure reactive,  acid hydrolyzable or total phosphorous. Separate reagents must be ordered to measure these forms of phosphorous with the appropriate meter. The HI93706-0 reagents are measuring ortho phosphate and reporting only the phosphorous portion.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93706-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Phosphorus Reagents (100 tests) - HI93706-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles and packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Amino Acid method. The reaction between phosphate and reagents causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93706-01\"\u003ePhosphorus Reagents (100 tests) - HI93706-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427395953,"sku":"HI93706-01","price":3682.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker-small-reagents_1_10_1_1_2_1_1_2.png?v=1792646645"},{"product_id":"phosphorus-reagents-300-tests-hi93706-03","title":"Phosphorus Reagents (300 tests) - HI93706-03","description":"\u003cp\u003eThe HI93706-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater,  18\u003csup\u003eth\u003c\/sup\u003e edition,  Amino Acid method. The reaction between phosphate and reagents causes a blue tint in the sample. By simply adding the reagents to the sample,  a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of phosphorus (P). These reagents are designed to be used with samples that have an expected range of of 0.0 to 15.0 mg\/L phosphorus.\u003c\/p\u003e\n\u003cp\u003eThese reagents do not measure reactive,  acid hydrolyzable or total phosphorous. Separate reagents must be ordered to measure these forms of phosphorous with the appropriate meter. The HI93706-0 reagents are measuring ortho phosphate and reporting only the phosphorous portion.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93706-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Phosphorus Reagents (300 tests) - HI93706-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles and packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Amino Acid method. The reaction between phosphate and reagents causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93706-03\"\u003ePhosphorus Reagents (300 tests) - HI93706-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427428721,"sku":"HI93706-03","price":10594.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker-small-reagents_1_10_1_1_2_1_1_1_1.png?v=1792646645"},{"product_id":"nitrite-low-range-reagents-100-tests-hi93707-01","title":"Nitrite Low Range Reagents (100 tests) - HI93707-01","description":"\u003cp\u003eThe HI93707-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  The method is an adaptation of the Diazotization method,  adapted from EPA method 354.1. The reaction between nitrite and the reagent causes a pink tint in the sample. By simply adding the reagent to the sample,  a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of nitrite. These reagents are designed to be used with samples that are within the expected range of the meter being used. Ranges available include 0.000 to 0.600 mg\/L nitrite with the portable photometer (HI96707) and 0.00 to 1.15 mg\/L nitrite with our compatible benchtop photometers.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93707-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrite Low Range Reagents (100 tests) - HI93707-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the EPA Diazotization method 354.1. The reaction between nitrite and the reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93707-01\"\u003eNitrite Low Range Reagents (100 tests) - HI93707-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427461489,"sku":"HI93707-01","price":4563.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker-small-reagents_1_10_1_1_2_1_1.png?v=1792646646"},{"product_id":"nitrite-low-range-reagents-300-tests-hi93707-03","title":"Nitrite Low Range Reagents (300 tests) - HI93707-03","description":"\u003cp\u003eThe HI93707-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  The method is an adaptation of the Diazotization method,  adapted from EPA method 354.1. The reaction between nitrite and the reagent causes a pink tint in the sample. By simply adding the reagent to the sample,  a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of nitrite. These reagents are designed to be used with samples that are within the expected range of the meter being used. Ranges available include 0.000 to 0.600 mg\/L nitrite with the portable photometer (HI96707) and 0.00 to 1.15 mg\/L nitrite with our compatible benchtop photometers.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93707-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrite Low Range Reagents (300 tests) - HI93707-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the EPA Diazotization method 354.1. The reaction between nitrite and the reagent causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93707-03\"\u003eNitrite Low Range Reagents (300 tests) - HI93707-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427723633,"sku":"HI93707-03","price":13086.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/checker-small-reagents_1_10_1_1_2_1_1_1.png?v=1792646647"},{"product_id":"nitrite-high-range-reagents-100-tests-hi93708-01","title":"Nitrite High Range Reagents (100 tests) - HI93708-01","description":"\u003cp\u003eThe HI93708-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow an adaptation of the Ferrous Sulfate method in which the reaction between nitrite and the reagent causes a color change in the sample. The intensity of color is determined by a compatible photometer and the concentration will be displayed in mg\/L (ppm) of nitrite. These reagents are designed to be used with samples that have an expected range of 0 to 150 mg\/L nitrite.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93708-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrite High Range Reagents (100 tests) - HI93708-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the Ferrous Sulfate method. The reaction between nitrite and the reagent causes a greenish-brown tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93708-01\"\u003eNitrite High Range Reagents (100 tests) - HI93708-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427756401,"sku":"HI93708-01","price":4872.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/small-reagents_1_8_1_2.png?v=1792646647"},{"product_id":"nitrite-high-range-reagents-300-tests-hi93708-03","title":"Nitrite High Range Reagents (300 tests) - HI93708-03","description":"\u003cp\u003eThe HI93708-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow an adaptation of the Ferrous Sulfate method in which the reaction between nitrite and the reagent causes a color change in the sample. The intensity of color is determined by a compatible photometer and the concentration will be displayed in mg\/L (ppm) of nitrite. These reagents are designed to be used with samples that have an expected range of 0 to 150 mg\/L nitrite.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI93708-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eNitrite High Range Reagents (300 tests) - HI93708-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ePackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Ferrous Sulfate method. The reaction between nitrite and the reagent causes a greenish-brown tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI93708-03\" target=\"_blank\" rel=\"noopener\"\u003eNitrite High Range Reagents (300 tests) - HI93708-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427789169,"sku":"HI93708-03","price":13684.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/small-reagents_1_8_1_1_1.png?v=1792646647"},{"product_id":"manganese-high-range-reagents-100-tests-hi93709-01","title":"Manganese High Range Reagents (100 tests) - HI93709-01","description":"\u003cp\u003eThe HI93709-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater,  18\u003csup\u003eth\u003c\/sup\u003e edition,  periodate method. The reaction between manganese and the reagents causes a violet tint in the sample. By simply adding the reagents to the sample,  a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of manganese. These reagents are designed to be used with samples that have an expected range of 0.0 to 20.0 mg\/L manganese.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93709-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Manganese High Range Reagents (100 tests) - HI93709-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93709-01\"\u003eManganese High Range Reagents (100 tests) - HI93709-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427887473,"sku":"HI93709-01","price":6546.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93709.jpg?v=1792646649"},{"product_id":"manganese-high-range-reagents-300-tests-hi93709-03","title":"Manganese High Range Reagents (300 tests) - HI93709-03","description":"\u003cp\u003eThe HI93709-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. The method is an adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, periodate method. The reaction between manganese and the reagents causes a violet tint in the sample. By simply adding the reagents to the sample, a reaction will take place and a compatible benchtop or portable meter can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of manganese. These reagents are designed to be used with samples that have an expected range of 0.0 to 20.0 mg\/L manganese.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI93709-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eManganese High Range Reagents (300 tests) - HI93709-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ePackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaptation of Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI93709-03\" target=\"_blank\" rel=\"noopener\"\u003eManganese High Range Reagents (300 tests) - HI93709-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427920241,"sku":"HI93709-03","price":18669.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93709_1.jpg?v=1792646649"},{"product_id":"total-chlorine-reagents-100-tests-hi93711-01","title":"Total Chlorine Reagents (100 tests) - HI93711-01","description":"\u003cp\u003eThe HI93711-01 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. The intensity of color is determined by a compatible photometer and the total chlorine concentration will be displayed in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L total chlorine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI93711-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine Reagents (100 tests) - HI93711-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ePackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between total chlorine and the reagents causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI93711-01\" target=\"_blank\" rel=\"noopener\"\u003eTotal Chlorine Reagents (100 tests) - HI93711-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871427953009,"sku":"HI93711-01","price":3342.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93711.jpg?v=1792646650"},{"product_id":"ammonia-medium-range-reagents-300-tests-hi93715-03","title":"Ammonia Medium Range Reagents (300 tests) - HI93715-03","description":"\u003cp\u003eThe HI93715-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the Nessler Method in which the reaction between ammonia and the reagent causes a color change in the sample. The intensity of color is determined by a compatible photometer and the concentration and based upon the meter will be displayed in mg\/L (ppm) as ammonia (NH\u003csub\u003e3\u003c\/sub\u003e) or ammonia nitrogen (NH\u003csub\u003e3\u003c\/sub\u003e-N). These reagents are designed to be used with samples that have an expected range of 0.00 to 9.99 mg\/L ammonia.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93715-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia Medium Range Reagents (300 tests) - HI93715-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles “A” and “B”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler Method. The reaction between ammonia and the reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93715-03\"\u003eAmmonia Medium Range Reagents (300 tests) - HI93715-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428018545,"sku":"HI93715-03","price":19261.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93715-0_1.jpg?v=1792646651"},{"product_id":"ph-photometer-reagents-100-tests-hi93710-01","title":"pH Photometer Reagents (100 tests) - HI93710-01","description":"\u003cp\u003eThe HI93710-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Phenol Red method in which the reagents produce a range of color that is pH-dependent. By simply adding 5 drops from the bottle of reagent to the sample,  the reaction between the sample and reagent causes a tint in the sample that varies from yellow to red. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in pH units with a resolution of 0.1 pH. These reagents are designed to be used with samples that have an expected range of 6.5 to 8.5 pH.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93710-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH Photometer Reagents (100 tests) - HI93710-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Phenol red method. The reaction with reagents causes a red tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93710-01\"\u003epH Photometer Reagents (100 tests) - HI93710-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428084081,"sku":"HI93710-01","price":2807.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93710-01.jpg?v=1792646651"},{"product_id":"ph-photometer-reagents-300-tests-hi93710-03","title":"pH Photometer Reagents (300 tests) - HI93710-03","description":"\u003cp\u003eThe HI93710-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the Phenol Red Method in which the reagents produce a range of color that is pH-dependent. By simply adding 5 drops from the bottle of reagent to the sample,  the reaction between the sample and reagent causes a tint in the sample that can vary from yellow to red. The intensity of color is determined by a compatible photometer and the concentration will be displayed. The results will be displayed in pH units with a resolution of 0.1 pH. These reagents are designed to be used with samples that have an expected range of 6.5 to 8.5 pH.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93710-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH Photometer Reagents (300 tests) - HI93710-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper Bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Phenol red method. The reaction with reagents causes a red tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93710-03\"\u003epH Photometer Reagents (300 tests) - HI93710-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428116849,"sku":"HI93710-03","price":7849.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93710-03.jpg?v=1792646652"},{"product_id":"total-chlorine-reagents-300-tests-hi93711-03","title":"Total Chlorine Reagents (300 tests) - HI93711-03","description":"\u003cp\u003eThe HI93711-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents follow the DPD Method in which the reaction between chlorine and reagent causes a pink tint in the sample. The intensity of color is determined by a compatible photometer and the total chlorine concentration will be displayed in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L total chlorine.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI93711-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTotal Chlorine Reagents (300 tests) - HI93711-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ePackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eadaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between total chlorine and the reagents causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI93711-03\" target=\"_blank\" rel=\"noopener\"\u003eTotal Chlorine Reagents (300 tests) - HI93711-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428149617,"sku":"HI93711-03","price":9038.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93711_1.jpg?v=1792646653"},{"product_id":"dpd3-liquid-reagent-for-total-chlorine-600-tests-hi93711-d3","title":"DPD3 Liquid Reagent for Total Chlorine (600 tests) - HI93711-D3","description":"\u003cp\u003eThe HI93711-D3 are high quality liquid reagents that allow for users to achieve fast and accurate colorimetric measurements.  These reagents follow an adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The methods use a DPD reagent in which the reaction between chlorine and reagent causes a pink tint in the sample. By simply adding the 3 drops of HI93701A-T(F) and 3 drops of HI93701B-T(F) and 1 drop of HI93711-D3 total chlorine can be measured. By adding the reagents to the sample,  the reaction will take place and one of Hanna’s compatible benchtop or portable photometers will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of total chlorine. These reagents are designed to be used with samples that have an expected range of 0.00 to 5.00 mg\/L total chlorine.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCompatible Photometers Include:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHI83200\u003c\/li\u003e\n\u003cli\u003eHI83203\u003c\/li\u003e\n\u003cli\u003eHI83205\u003c\/li\u003e\n\u003cli\u003eHI83206\u003c\/li\u003e\n\u003cli\u003eHI83208\u003c\/li\u003e\n\u003cli\u003eHI83099\u003c\/li\u003e\n\u003cli\u003eHI96724\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93711-D3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e DPD3 Liquid Reagent for Total Chlorine (600 tests) - HI93711-D3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 600 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the USEPA method 330.5 and Standard Method 4500-Cl G. The reaction between chlorine and the reagents causes a pink tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93711-D3\"\u003eDPD3 Liquid Reagent for Total Chlorine (600 tests) - HI93711-D3\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428215153,"sku":"HI93711-D3","price":4053.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/dpd3-liquid-reagent-for-total-chlorine-600-tests-hi93711-d3.jpg?v=1792646654"},{"product_id":"aluminum-reagents-100-tests-hi93712-01","title":"Aluminum Reagents (100 tests) - HI93712-01","description":"\u003cp\u003eThe HI93712-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements. These reagents are part of a method that is an adaption of the aluminon method. The reaction between the reagents and aluminum produces a reddish tint in the sample. By adding the reagents to the sample,  a reaction will take place and a compatible photometer can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of aluminum. These reagents are designed to be used with samples that have an expected range of 0.00 to 1.00 mg\/L aluminum.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eCompatible Photometers Include:\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eHI83200\u003c\/li\u003e\n\u003cli\u003eHI83205\u003c\/li\u003e\n\u003cli\u003eHI83099\u003c\/li\u003e\n\u003cli\u003eHI96712\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93712-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Aluminum Reagents (100 tests) - HI93712-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaption of the aluminon method. The reaction between aluminum and reagents causes a reddish tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93712-01\"\u003eAluminum Reagents (100 tests) - HI93712-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428247921,"sku":"HI93712-01","price":12721.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93712.jpg?v=1792646653"},{"product_id":"aluminum-reagents-300-tests-hi93712-03","title":"Aluminum Reagents (300 tests) - HI93712-03","description":"\u003cp\u003eThe HI93712-03 are high quality reagents that are pre-measured, allowing for users to achieve fast and accurate colorimetric measurements. These reagents are part of a method that is an adaption of the aluminon method. The reaction between the reagents and aluminum produces a reddish tint in the sample. By adding the reagents to the sample, a reaction will take place and a compatible photometer can be used to determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of aluminum. These reagents are designed to be used with samples that have an expected range of 0.00 to 1.00 mg\/L aluminum.\u003c\/p\u003e\n\u003ch5\u003eCompatible Photometers Include:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eHI83200\u003c\/li\u003e\n\u003cli\u003eHI83205\u003c\/li\u003e\n\u003cli\u003eHI83099\u003c\/li\u003e\n\u003cli\u003eHI96712\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI93712-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAluminum Reagents (300 tests) - HI93712-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ePackets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003eAdaption of the aluminon method. The reaction between aluminum and reagents causes a reddish tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI93712-03\" target=\"_blank\" rel=\"noopener\"\u003eAluminum Reagents (300 tests) - HI93712-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428411761,"sku":"HI93712-03","price":37477.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93712_1.jpg?v=1792646655"},{"product_id":"phosphate-low-range-reagents-100-tests-hi93713-01","title":"Phosphate Low Range Reagents (100 tests) - HI93713-01","description":"\u003cp\u003eThe HI93713-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  The method is an adaptation of the ascorbic acid method in which the reaction between phosphate and the reagent causes a blue tint in the sample. The intensity of color is determined by a compatible photometer and the phosphate concentration will be displayed in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 2.50 mg\/L (ppm) phosphate.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93713-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Phosphate Low Range Reagents (100 tests) - HI93713-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ascorbic acid method. The reaction between phosphate and the reagent causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93713-01\"\u003ePhosphate Low Range Reagents (100 tests) - HI93713-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428444529,"sku":"HI93713-01","price":4053.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93713-0.jpg?v=1792646656"},{"product_id":"phosphate-low-range-reagents-300-tests-hi93713-03","title":"Phosphate Low Range Reagents (300 tests) - HI93713-03","description":"\u003cp\u003eThe HI93713-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  The method is an adaptation of the ascorbic acid method in which the reaction between phosphate and the reagent causes a blue tint in the sample. The intensity of color is determined by a compatible photometer and the phosphate concentration will be displayed in mg\/L (ppm). These reagents are designed to be used with samples that have an expected range of 0.00 to 2.50 mg\/L (ppm) phosphate.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93713-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Phosphate Low Range Reagents (300 tests) - HI93713-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ascorbic acid method. The reaction between phosphate and the reagent causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93713-03\"\u003ePhosphate Low Range Reagents (300 tests) - HI93713-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428510065,"sku":"HI93713-03","price":11418.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93713-0_1.jpg?v=1792646656"},{"product_id":"cyanide-reagents-100-tests-hi93714-01","title":"Cyanide Reagents (100 tests) - HI93714-01","description":"\u003cp\u003eThe HI93714-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents are used in a method that is adapted from the Standard Methods for the Examination of Water and Wastewater,  18\u003csup\u003eth\u003c\/sup\u003e edition,  Pyridine-Pyrazalone method. The reaction between cyanide and reagents causes a blue tint in the sample. By simply adding the HI93714-01 reagents to the sample,  the reaction will take place and Hanna’s compatible portable photometer will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of cyanide. These reagents are designed to be used with samples that have an expected range of 0.000 to 0.200 mg\/L cyanide.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93714-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Cyanide Reagents (100 tests) - HI93714-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Bottles and packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Pyridine-Pyrazalone method. The reaction between cyanide and reagents causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93714-01\"\u003eCyanide Reagents (100 tests) - HI93714-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428542833,"sku":"HI93714-01","price":10001.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93714-03_1.jpg?v=1792646657"},{"product_id":"cyanide-reagents-300-tests-hi93714-03","title":"Cyanide Reagents (300 tests) - HI93714-03","description":"\u003cp\u003eThe HI93714-03 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents are used in a method that is adapted from the Standard Methods for the Examination of Water and Wastewater,  18\u003csup\u003eth\u003c\/sup\u003e edition,  Pyridine-Pyrazalone method. The reaction between cyanide and reagents causes a blue tint in the sample. By simply adding the HI93714-03 reagents to the sample,  the reaction will take place and Hanna’s compatible portable photometer will determine the concentration from the color that is produced. The results will be displayed in mg\/L (ppm) of cyanide. These reagents are designed to be used with samples that have an expected range of 0.000 to 0.200 mg\/L cyanide.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93714-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Cyanide Reagents (300 tests) - HI93714-03\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Bottles and packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 300 Tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Pyridine-Pyrazalone method. The reaction between cyanide and reagents causes a blue tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93714-03\"\u003eCyanide Reagents (300 tests) - HI93714-03\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428608369,"sku":"HI93714-03","price":29741.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93714-03.jpg?v=1792646657"},{"product_id":"ammonia-medium-range-reagents-100-tests-hi93715-01","title":"Ammonia Medium Range Reagents (100 tests) - HI93715-01","description":"\u003cp\u003eThe HI93715-01 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate colorimetric measurements.  These reagents follow the Nessler Method in which the reaction between ammonia and the reagent causes a color change in the sample. The intensity of color is determined by a compatible photometer and the concentration and based upon the meter will be displayed in mg\/L (ppm) as ammonia (NH\u003csub\u003e3\u003c\/sub\u003e) or ammonia nitrogen (NH\u003csub\u003e3\u003c\/sub\u003e-N). These reagents are designed to be used with samples that have an expected range of 0.00 to 9.99 mg\/L ammonia.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI93715-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia Medium Range Reagents (100 tests) - HI93715-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Dropper bottles “A” and “B”\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Adaptation of the ASTM Manual of Water and Environmental Technology, D1426-93, Nessler Method. The reaction between ammonia and the reagents causes a yellow tint in the sample.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI93715-01\"\u003eAmmonia Medium Range Reagents (100 tests) - HI93715-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871428641137,"sku":"HI93715-01","price":6659.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi93715-0.jpg?v=1792646658"}],"url":"https:\/\/hannainst.in\/collections\/photometer-reagents-reagents.oembed","provider":"hanna","version":"1.0","type":"link"}