{"title":"Process Control – Probes","description":"","products":[{"product_id":"orp-electrode-for-process-control-and-monitoring-hi2001","title":"ORP Electrode for Process Control and Monitoring - HI2001","description":"\u003cp\u003eThe HI2001 has a  platinum sensor  for the measurement of ORP for a variety of applaictions including plating,  swimming pools,  water treatemnt and food disinfection. The platinum sensoris commonly used to monitor the addition of oxidizing chemicals including chlorine,  chlorine dioxide and ozone.  The probe can be used for monitoring the additin of reducing chemicals like sodium metabisulfite.\u003c\/p\u003e\n\u003cp\u003eThis cost effective probe has threads on both ends for in-line or submeraion mounting.\u003c\/p\u003e\n\u003ch4\u003eSensor Type\u003c\/h4\u003e\n\u003cp\u003ePlatinum sensor provides the best response over a wide range of applications.\u003c\/p\u003e\n\u003ch5\u003ePVDF Body\u003c\/h5\u003e\n\u003cp\u003ePolyvinylidene fluoride (PVDF) is a plastic that is resistant to most chemicals and solvents. It has high abrasion resistance,  mechanical strength,  and resistance to ultraviolet and nuclear radiation.\u003c\/p\u003e\n\u003ch5\u003ePTFE Junction\u003c\/h5\u003e\n\u003cp\u003eThis type of junction is often used on electrodes with polymer electrolytes. Porous polytetrafluoroethylene (PTFE) is a hydrophobic material that is available with different porosities that helps to minimize clogging. PTFE is widely used in industrial applications due to its high range of chemical resistantance.\u003c\/p\u003e\n\u003ch5\u003eBNC Connector\u003c\/h5\u003e\n\u003cp\u003eThe HI2001 uses a BNC connector. This type of connector is universal in that it can be used on any ORP process controller,  indicator,  or transmitter that has the female BNC probe input.\u003c\/p\u003e\n\u003ch5\u003eExternal Thread\u003c\/h5\u003e\n\u003cp\u003eThe ½\" NPT thread of the HI2001 front end allows for in-line installation in pipes while the 3\/4\" threads on the backend (cable side) allows for submersion mounting with tanks or other vessels.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e ORP Electrode for Process Control and Monitoring - HI2001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo\/Portata Giunzione\u003c\/td\u003e\n\u003ctd\u003e doppia, PTFE\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di Elettrolita\u003c\/td\u003e\n\u003ctd\u003e polimero\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressione Max.\u003c\/td\u003e\n\u003ctd\u003e 6 bar (87 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLunghezza Complessiva\u003c\/td\u003e\n\u003ctd\u003e 86 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSensore di Temperatura\u003c\/td\u003e\n\u003ctd\u003e da -5 a 80°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCavo\u003c\/td\u003e\n\u003ctd\u003e 3 m \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTipo di Connettore\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI2001\"\u003eORP Electrode for Process Control and Monitoring - HI2001\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871237800305,"sku":"HI2001","price":20961.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2001_720x720_72_rgb_1.jpg?v=1792645916"},{"product_id":"amplified-amphel-ph-general-purpose-electrode-hi2910b-5","title":"Amplified AmpHel® pH General Purpose Electrode – HI2910B\/5","description":"\u003cp\u003eAmpHel® pH Electrode with Internal Battery,  PEI body,  gel electrolyte\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI2910B\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Amplified AmpHel\u003csup\u003e®\u003c\/sup\u003e pH General Purpose Electrode – HI2910B\/5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e Cloth\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e Gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e General Purpose (-5 to 70°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 3 bar (43.5 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 148.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 5 m\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI2910B\/5\"\u003eAmplified AmpHel\u003csup\u003e®\u003c\/sup\u003e pH General Purpose Electrode – HI2910B\/5\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248613745,"sku":"HI2910B\/5","price":22908.15,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi2910b-1461x1472-9939f2f1-7d67-4bc5-9c9f-e815a61d88be.jpg?v=1792645932"},{"product_id":"amphel-platinum-type-orp-electrodes-with-replaceable-battery","title":"AmpHel® Platinum-Type ORP Electrodes with Replaceable Battery - HI6293005","description":"\u003ch5\u003eAmplified ORP electrode\u003c\/h5\u003e\n\u003cp\u003eProvides a stable signal for industrial monitoring as well as a major saving in low noise coaxial cable costs.\u003c\/p\u003e\n\u003ch5\u003ePEI body\u003c\/h5\u003e\n\u003cp\u003ePEI bodied electrodes are rugged and suitable for noncritical applications that require a very good combination of chemical,  mechanical,  and thermal resistance.\u003c\/p\u003e\n\u003ch5\u003eCloth junction\u003c\/h5\u003e\n\u003cp\u003eClear the junction by simply extracting 1\/8” of the junction from the electrode to expose a new portion,  resulting in a renewed junction.\u003c\/p\u003e\n\u003ch5\u003eBNC connector\u003c\/h5\u003e\n\u003cp\u003eAllows for quick and easy connection to any pH\/ORP meter or transmitter.\u003c\/p\u003e\n\u003ch5\u003ePlatinum sensor\u003c\/h5\u003e\n\u003cp\u003eProvides the best response over a wide range of applications.\u003c\/p\u003e\n\u003ch5\u003eAmpHel® replaceable battery\u003c\/h5\u003e\n\u003cp\u003eNo longer necessary to throw away an electrode when the battery is exhausted for longer electrode life.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI6293005\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e AmpHel\u003csup\u003e®\u003c\/sup\u003e Platinum-Type ORP Electrodes with Replaceable Battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI6293005\"\u003eAmpHel\u003csup\u003e®\u003c\/sup\u003e Platinum-Type ORP Electrodes with Replaceable Battery\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322702193,"sku":"HI6293005","price":33588.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6293005-1500x1500-27267396-d49b-44c2-9e89-b0066b8af4c8_1.jpg?v=1792646148"},{"product_id":"in-line-conductivity-probe-with-pt100-sensor-3m-cable-hi7639-3m-9-84","title":"In-line Conductivity Probe with Pt100 Sensor,  3m Cable - HI7639-3m (9.84')","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Conductivity-Probes-Diagram-1_00000002.jpg\" alt=\"HI7639 conductivity probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e\u003cstrong\u003eAdvantage of Four Ring Conductivity Probe\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThree types of conductivity probes are manufactured by Hanna, amperometric (2 Ring), potentionmetric (Four Ring) and Inductive (Electrodeless or Toroidal conductivity probe).\u003c\/p\u003e\n\u003cp\u003eFour electrode conductivity (four-ring conductivity) utilizes a potentionmetric approach to make the measurement; an alternating current is applied to the outer two \"drive\"electrodes to induce a current in the solution. The voltage is measured between the inner pair of electrodes in solution. The voltage is proportional the conductivity This technology extends the linear range of measurement over three decades. Electrodes are made of graphite, stainless steel or Platinum. Polarization effects are reduced.\u003c\/p\u003e\n\u003cp\u003eThe universally acclaimed four-ring method provides an exceptionally stable measurement over a wider range.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThese probes do not suffer polarization\u003c\/li\u003e\n\u003cli\u003eNo need of frequent calibration or cell changes.\u003c\/li\u003e\n\u003cli\u003eMore Stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHI7639 Conductivity Electrode FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch4\u003eIn-line conductivity probe\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eSuitable for direct immersion in pipes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eBuilt-in Pt100 temperature sensor\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvide accurate and effective temperature compensation.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eColor coded wires\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003e3m cable incorporating color coded wires for easy connection to transmitters .\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003ePlatinum sensor\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvides the best response over a wide range of applications.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003ePEI body\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003ePEI bodied electrodes are rugged and suitable for noncritical applications that require a very good combination of chemical, mechanical, and thermal resistance.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eFour-ring method\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvides an exceptionally stable measurement over a wider range. These probes do not suffer polarization, nor do they need frequent calibration or cell changes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7639\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eIn-line Conductivity Probe with Pt100 Sensor, 3m Cable - HI7639-3m (9.84')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7639\" target=\"_blank\" rel=\"noopener\"\u003eIn-line Conductivity Probe with Pt100 Sensor, 3m Cable - HI7639-3m (9.84')\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322800497,"sku":"HI7639","price":53735.4,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ec-tds-probe-with-pt100-sensor.jpg?v=1792646150"},{"product_id":"ec-tds-probe-for-low-range-mini-controllers-2-m-cable","title":"EC\/TDS probe for low range Mini Controllers, 2 m cable - HI7634-00","description":"\u003ch4\u003eTwo-Pole Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI7634-00 is an amperometric sensor, utilizing two-pole technology to achieve accurate EC and TDS measurements. An alternating voltage is applied to the two electrodes and the generated current is measured.\u003c\/p\u003e\n\u003ch4\u003enternal Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eThe integrated temperature sensor of the HI7634-00 probe is crucial for accurate EC and TDS measurements. Changes in temperature of a solution will change the ion mobility, which will influence the measurement. For this reason it is important that a fast and stable temperature measurement be taken in order to provide an accurate temperature compensated EC and TDS reading.\u003c\/p\u003e\n\u003ch4\u003eThreaded Connection\u003c\/h4\u003e\n\u003cp\u003eThe ½” NPT threaded connection of the HI7634-00 allows for insertion mounting into a common “T” fitting without the need for additional hardware.\u003c\/p\u003e\n\u003ch4\u003eMultiple Cable Lengths\u003c\/h4\u003e\n\u003cp\u003eThe HI7634-00 is available with varying lengths of cable based on your specific requirements.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI7634-00 comes with 2 meters (6.6 feet) of cable attached.\u003c\/li\u003e\n\u003cli\u003eHI7634-00\/4 comes with 4 meters (13.1 feet) of cable attached.\u003c\/li\u003e\n\u003cli\u003eHI7634-00\/5 comes with 5 meters (16.4 feet) of cable attached.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eCompatible Mini Controllers:\u003c\/h4\u003e\n\u003cp\u003eBL983322 - Conductivity mini-controller with a 0.00 - 19.99 µS\/cm measurement range\u003c\/p\u003e\n\u003cp\u003eBL983320 - Conductivity mini-controller with a 0.0 - 199.9 µS\/cm measurement range\u003c\/p\u003e\n\u003cp\u003eBL983313 - Conductivity mini-controller with a 0 - 1999 µS\/cm measurement range\u003c\/p\u003e\n\u003cp\u003eBL983321 - TDS mini-controller with a 0.00 - 19.99 ppm measurement range\u003c\/p\u003e\n\u003cp\u003eBL983324 - TDS mini-controller with a 0.0 - 49.9 ppm measurement range\u003c\/p\u003e\n\u003cp\u003eBL983315 - TDS mini-controller with a 0.0 - 199.9 ppm measurement range\u003c\/p\u003e\n\u003cp\u003eBL983329 - TDS mini-controller with a 0 - 999 ppm measurement range\u003c\/p\u003e\n\u003cp\u003eBL983319 - TDS mini-controller with a 0 - 1999 ppm measurement range\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n                  \u003cthead\u003e\n                    \u003ctr\u003e\n                      \u003cth\u003eSpecification\u003c\/th\u003e\n                      \u003cth\u003eDetail\u003c\/th\u003e\n                    \u003c\/tr\u003e\n                  \u003c\/thead\u003e\n                  \u003ctbody\u003e\n\n      \n                  \u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eSKU\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eHI7634-00\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eRange\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e0 to 1999 µS\/cm\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eAccuracy (@25˚C\/77˚F)\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e±2% F.S.\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eRecommended Operating Temperature\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003eautomatic from, 5 to 50˚C (41 to 122˚F) with β=2%\/˚C\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTip \/ Shape\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e2 electrode probe\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBody Length\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e64 mm (2.5)\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eCable\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e2 m (6.6'), 4 m (13.1'), 5 m (16.4') based on selection\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eRecommended Use\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003econtrollers, process equipment\n\n                \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n                    \u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eConnection\u003c\/strong\u003e\u003c\/td\u003e\n                    \u003ctd\u003e½in. threaded male NPT\n\n                \n             \n                  \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n                \u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871405113713,"sku":"HI7634-00","price":6458.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-3502x3503-d9358726-5b43-4766-b483--scaled.jpg?v=1792646445"},{"product_id":"galvanic-do-probe-for-hi8410-process-4-m-cable-hi76410","title":"Galvanic DO probe for HI8410 process, 4 m cable - HI76410\/4","description":"\u003ch5\u003eGalvanic DO Probe\u003c\/h5\u003e\n\u003cp\u003eProvided with a membrane covering the galvanic sensor.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Thermistor Temperature Sensor\u003c\/h5\u003e\n\u003cp\u003eEnsures fast,  accurately compensated readings even during sudden temperature fluctuations.\u003c\/p\u003e\n\u003ch5\u003eDIN Connector\u003c\/h5\u003e\n\u003cp\u003eMulti-pin sensor connector is manufacturer specfic and allows for easy connection to the compatable meter.\u003c\/p\u003e\n\u003ch5\u003eVariety of Cable Lengths\u003c\/h5\u003e\n\u003cp\u003eModels can be ordered with either a 4 m,  10 m,  or 30 m cable length to meet your process needs.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI76410\/4\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 4m (13')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI76410\/4\"\u003e4m (13')\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871406129521,"sku":"HI76410\/4","price":43677.0,"currency_code":"INR","in_stock":true}]},{"product_id":"galvanic-do-probe-for-hi8410-process-10m-cable-hi76410","title":"Galvanic DO probe for HI8410 process, 10m cable - HI76410\/10","description":"\u003ch5\u003eGalvanic DO Probe\u003c\/h5\u003e\n\u003cp\u003eProvided with a membrane covering the galvanic sensor.\u003c\/p\u003e\n\u003ch5\u003eBuilt-in Thermistor Temperature Sensor\u003c\/h5\u003e\n\u003cp\u003eEnsures fast,  accurately compensated readings even during sudden temperature fluctuations.\u003c\/p\u003e\n\u003ch5\u003eDIN Connector\u003c\/h5\u003e\n\u003cp\u003eMulti-pin sensor connector is manufacturer specfic and allows for easy connection to the compatable meter.\u003c\/p\u003e\n\u003ch5\u003eVariety of Cable Lengths\u003c\/h5\u003e\n\u003cp\u003eModels can be ordered with either a 4 m,  10 m,  or 30 m cable length to meet your process needs.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI76410\/10\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e 10m (32.8')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI76410\/10\"\u003e10m (32.8')\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871406162289,"sku":"HI76410\/10","price":51418.0,"currency_code":"INR","in_stock":true}]},{"product_id":"ec-tds-probe-for-high-range-mini-controllers-2-m-cable-hi7632-00","title":"EC\/TDS Probe For High Range Mini Controllers, 2 M Cable - HI7632-00","description":"\u003ch5\u003eTwo-Pole Probe\u003c\/h5\u003e\n\u003cp\u003eThe HI7632-00 is an amperometric sensor, utilizing two-pole technology to achieve accurate EC and TDS measurements. An alternating voltage is applied to the two electrodes and the generated current is measured. The HI7632-00 is compatible with the following mini controllers that measure in the high range:\u003c\/p\u003e\n\u003ch5\u003eEC:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eBL983317\u003c\/li\u003e\n\u003cli\u003eBL983327\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eTDS:\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eBL983318\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eInternal Temperature Sensor\u003c\/h5\u003e\n\u003cp\u003eThe integrated temperature sensor of the HI7632-00 probe is crucial for accurate EC and TDS measurements. Changes in temperature of a solution will change the ion mobility, which will influence the measurement. For this reason it is important that a fast and stable temperature measurement be taken in order to provide an accurate temperature compensated EC and TDS reading.\u003c\/p\u003e\n\u003ch5\u003eThreaded Connection\u003c\/h5\u003e\n\u003cp\u003eThe ½” NPT threaded connection of the HI7632-00 allows for insertion mounting into a common “T” fitting without the need for additional hardware.\u003c\/p\u003e\n\u003ch5\u003eMultiple Cable Lengths\u003c\/h5\u003e\n\u003cp\u003eThe HI7632-00 is available with varying lengths of cable based on your specific requirements.\u003c\/p\u003e\n\u003cp\u003eHI7632-00 comes with 2 meters (6.6 feet) of cable attached.\u003c\/p\u003e\n\u003cp\u003eHI7632-00\/6 comes with 6 meters (19.7 feet) of cable attached.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7632-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eEC\/TDS Probe For High Range Mini Controllers, 2 M Cable - HI7632-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25˚C\/77˚F)\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Operating Temperature\u003c\/td\u003e\n\u003ctd\u003eautomatic from, 5 to 50˚C (41 to 122˚F) with β=2%\/˚C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e2 electrode probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\u003c\/td\u003e\n\u003ctd\u003e64 mm (2.5\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e2 m (6.6') and 6 m (19.7') based on selection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003econtrollers, process equipment\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnection\u003c\/td\u003e\n\u003ctd\u003e½” threaded male NPT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871458263409,"sku":"HI7632-00","price":6458.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317-2-BL-Series-Controllers-HI7632-probe.jpg?v=1792646952"},{"product_id":"flow-thru-conductivity-probe-hi3001","title":"Flow-thru Conductivity Probe – HI3001","description":"\u003ch4\u003eFour-Ring Probe\u003c\/h4\u003e\n\u003cp\u003eThe HI3001 is a potentiometric sensor’s four-ring technology achieves accurate EC measurements by avoiding  polarization effects and allowing a wide range of measurements with a single probe. The platinum sensors are protected by a PEI cover that can easily be removed for quick maintenance.\u003c\/p\u003e\n\u003ch4\u003eInternal Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eThe integrated NTC temperature sensor of the HI3001 improves the accuracy of EC measurements by providing fast and stable temperature measurement for accurately compensated EC readings.\u003c\/p\u003e\n\u003ch4\u003eThreaded Connection\u003c\/h4\u003e\n\u003cp\u003eThe ½” front NPT threaded connection of the HI3001 allows for flow-thru mounting,  while the ¾” back threads allow for submersion or pipe mounting without the need for additional hardware.\u003c\/p\u003e\n\u003ch4\u003ePVDF Body\u003c\/h4\u003e\n\u003cp\u003ePolyvinylidene fluoride (PVDF) plastic is resistant to most chemicals and solvents with high abrasion resistance,  mechanical strength,  and resistance to ultraviolet and nuclear radiation. PVDF is also resistant to fungal growth.\u003c\/p\u003e\n\u003ch4\u003eMultiple Cable Lengths\u003c\/h4\u003e\n\u003cp\u003eThe HI3001D models feature a DIN connector for use with Hanna’s HI99XX series of wall-mounted controllers,  along with varying lengths of cable. HI3001D comes with a DIN connector and 3 meters (9.9’) of cable attached. HI3001D\/5 comes with a DIN connector and 5 meters (16.4’) of cable attached. HI3001D\/10 comes with a DIN connector and 10 meters (32.8’) of cable attached.\u003c\/p\u003e\n\u003ch4\u003ePEI Protective Cover\u003c\/h4\u003e\n\u003cp\u003eThe protective cover is made of PEI and can be removed for quick maintenance. These probes can withstand temperatures up to 80℃ (176℉) and 6 bars (87 psi) of pressure.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Flow-thru Conductivity Probe – HI3001\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3001\"\u003eFlow-thru Conductivity Probe – HI3001\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871462195569,"sku":"HI3001","price":32836.05,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3001-2100x2100-ca2ad641-dc52-46f9-a410-0b049071eb11.jpg?v=1792646990"},{"product_id":"in-line-conductivity-probe-with-ntc-sensor-for-immersion-installation-hi7638","title":"In-line Conductivity probe with NTC sensor for immersion installation – HI7638","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Conductivity-Probes-Diagram-1_00000002_9728e994-24d8-4828-8fd0-e631d7c3f9df.jpg\" alt=\"HI7639 conductivity probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e\u003cstrong\u003eAdvantage of Four Ring Conductivity Probe \u003c\/strong\u003e\u003c\/h4\u003e\n\u003cp\u003eThree types of conductivity probes are manufactured by Hanna,  amperometric (2 Ring),  potentionmetric (Four Ring) and Inductive (Electrodeless or Toroidal conductivity probe).\u003c\/p\u003e\n\u003cp\u003eFour electrode conductivity (four-ring conductivity) utilizes a potentionmetric approach to make the measurement; an alternating current is applied to the outer two “drive”electrodes to induce a current in the solution. The voltage is measured between the inner pair of electrodes in solution. The voltage is proportional the conductivity This technology extends the linear range of measurement over three decades. Electrodes are made of graphite,  stainless steel or Platinum. Polarization effects are reduced.\u003c\/p\u003e\n\u003cp\u003eThe universally acclaimed four-ring method provides an exceptionally stable measurement over a wider range.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eThese probes do not suffer polarization\u003c\/li\u003e\n\u003cli\u003eNo need of frequent calibration or cell changes.\u003c\/li\u003e\n\u003cli\u003eMore Stability\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHI7638 Conductivity Electrode FEATURES\/BENEFITS:\nIn-line conductivity probe\n\nSuitable for direct immersion in pipes.\n\nBuilt-in NTC temperature sensor \n\nThe integrated NTC temperature sensor of the HI7638 probe is crucial for accurate EC measurements. Since the temperature of a solution can drastically change the amount of conductance,  obtaining a fast and stable temperature measurement allows for an accurately compensated EC reading.\n\nMultiple Cable Lengths\u003c\/h4\u003e\n\u003cp\u003eThe HI7638 available in various lengths of cable.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI7638 comes with a DIN connector and 3 meters of cable attached.\u003c\/li\u003e\n\u003cli\u003eHI7638\/10 comes with a DIN connector and 10 meters of cable attached.\u003c\/li\u003e\n\u003cli\u003eHI7638\/20 comes with a DIN connector and 20 meters of cable attached.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePlatinum sensor\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvides the best response over a wide range of applications.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003ePEI body\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003ePEI bodied electrodes are rugged and suitable for noncritical applications that require a very good combination of chemical,  mechanical,  and thermal resistance.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eFour-ring method\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eProvides an exceptionally stable measurement over a wider range. These probes do not suffer polarization,  nor do they need frequent calibration or cell changes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7638\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e In-line Conductivity probe with NTC sensor for immersion installation – HI7638-3m (9.84′)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7638\"\u003eIn-line Conductivity probe with NTC sensor for immersion installation – HI7638-3m (9.84′)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871462228337,"sku":"HI7638","price":55717.2,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7638-2100x2100-02c36c9c-8aba-4150-877b-7e327998b84c.jpg?v=1792646990"},{"product_id":"hi1000-series-process-digital-ph-probe","title":"HI1000 Series Process Digital pH Probe - HI1002\/3","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eA Worldwide Leader in Electrode Manufacturing\u003c\/h5\u003e\n\u003cp\u003eSince the beginning of the 1990’s Hanna has been a leader in the research \u0026amp; development of pH electrode technology. The HI1000 series of digital pH probes represent the continual evolution of the technology. The HI1000 series perform all measurements within the probe and then transfer the data digitally to a process meter with a digital probe input.\u003c\/p\u003e\n\u003cp\u003eThe use of digital sensors allows for a process meter to be updated measuring a different parameter without changing controllers. This technology allows for a facility that has multiple control points to only have to maintain a single version of a controller.\u003c\/p\u003e\n\u003cp\u003eThe other advantage is that the digital transmission of measurement data is immune to electrical noise generated by motors,  pumps,  and humid environments. The digital signal can be transmitted over very long distances. This cannot be done with a standard analog probe unless it is amplified or a transmitter is used. The HI1000 of digital probes are available with cable lengths up to 50 meters.\u003c\/p\u003e\n\u003cp\u003eAll Hanna industrial digital pH electrodes are combination type,  i.e. the reference half cell and the measurement half cell are assembled in the same body. All of the probes are made with a chemically resistant PVDF body and have a pt100 temperature sensor for automatic temperature compensation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/flat_tip_advantage.jpg\" alt=\"Flat tip pH Electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e\u003cstrong\u003eAdvantage of flat tip electrodes\u003c\/strong\u003e\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eIn a continuous in-line installation,  the glass sensor of the pH electrode can be physically damaged by solution streams containing suspended solids.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eOur Flat Tip electrodes are the best answer to this problem. The flat tip virtually eliminates deposits that can foul the electrode,  significantly reducing necessary maintenance.\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003eThis characteristic makes flat tip electrodes ideal for continuous in-line monitoring and for solutions containing aggressive chemicals.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/matching_flat_pin.jpg\" alt=\"matching pin\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eEach pH electrode is provided with an internal matching pin that helps to avoid typical problems caused by grounding loop current,  such as:\n\nprogressive damage of the electrode\nfluctuating measurements\npoor process regulation\u003c\/h4\u003e\n\u003cp\u003eIn many industrial applications there is a potential for a ground loop. This can happen when the ground of the process is different than the ground of a controller\/transmitter.\u003c\/p\u003e\n\u003cp\u003eWhen a traditional electrode\/controller system is used,  the electrode reference is connected from the electrode to the instrument and current can flow through the reference half cell,  causing fluctuations in reading and serious damage to the Ag\/AgCl element. The potential matching pin shields the reference from external electrical fields. Shown above,  the matching pin allows the measurement to stabilize and ensures effective process regulation. In order to function properly,  the matching pin has to be continuously immersed in the measured solution and for this reason is placed near the electrode junction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1006_line_art.jpg\" alt=\"Flat tip pH dimensions \" width=\"720\" height=\"480\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eInstallation\u003c\/h4\u003e\n\u003cp\u003eThese electrodes have been designed with ¾” external thread for easy installation for in-line applications. HANNA instruments® also provides a series of probe holders for submersion tank installations.\u003c\/p\u003e\n\u003ch4\u003eFront thread ¾” NPT\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDirect in-line installation ¾” standard tee\u003c\/li\u003e\n\u003cli\u003eImmersion installation in vessel,  tank,  plating bath with HI 60501 (PVC) or HI 60503 (PVDF) electrode holders with adjustable immersion level: min 10 cm,  max 70 cm\u003c\/li\u003e\n\u003cli\u003eDirect pipe installation with HI 60542 PVC electrode holder,  2″ thread\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003ch4 style=\"margin-top: 0;\"\u003eHI1000 Series Flat Tip Digital pH Electrode FEATURES\/BENEFITS:\n\nJunction\nTwo junction types are available:\n\nAnnular non-clogging PTFE junction,  for testing solutions with high content of suspended solids,  aggressive chemicals,  or for high pressure installation\nCeramic junction that is ideal for drinking water and other low conductivity applications.\n\nGlass Sensor\nHI1000 series is available with three types of specialized glass.\n\nLT glass for low temperatures (-5 to 80 ℃). The resistance of the glass is low and increases to ideal resistance as the temperature increases.\nHT glass for high temperatures (0 to 100 ℃). The HT glass has a high resistance that increases to the ideal temperature as the temperature increases. The HT glass is ideal for highly alkaline pH measurement due to reduced amount of sodium error as compared to other glass types.\nHF glass is for samples that contain fluoride as hydrofluoric acid. This glass type is resistant to HF up to 2 g\/L of fluoride at a pH of 2 or greater.\n\nTemperature Sensor\n\nAll HI1000 series of digital pH electrodes have a built-in 3-wire Pt100 temperature sensor that allows for the temperature compensation of pH readings as well as temperature measurements.\n\nConnection Type\n\nElectrodes are wired for direct connection to the HI510 Universal Process Controller.\n\nCable Length\n\nHI1000 digital pH probes are available with a 5,  10,  15,  25,  or 50 m of cable.\n\nPVDF Body\n\nThe PVDF body used for the Flat Tip Series withstands high pressure and high temperature applications,  and guarantees a high chemical and mechanical resistance. These characteristics make the PVDF material the most recommended for many industrial applications.\u003c\/h4\u003e\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI1002\/3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI1000 Series Process Digital pH Probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e digital pH probe with built-in pt100 temperature sensor\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e LT glass: 0 to 12 pH\u003cbr\u003eHT glass: 0 to 14 pH\u003cbr\u003eHF glass: 0 to 10 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double junction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e polymer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PVDF\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGlass Type\u003c\/td\u003e\n\u003ctd\u003e based on configuration: LT (low temperature), HT (high temperature), or HF (hydrofluoric acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e flat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e LT glass -5 to 80 ºC (23 to 156 ºF) \u003cbr\u003e HT glass 0 to 100 ºC (32 to 212 ºF)\u003cbr\u003e HF glass F- \u0026lt; 2g\/L, temperature  2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 6 bar (87 psi)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 140 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e pt100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 22.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOutput Signal\u003c\/td\u003e\n\u003ctd\u003e digital RS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e direct wire connection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eProbe Mounting\u003c\/td\u003e\n\u003ctd\u003e 3\/4 in. NPT threaded connection for in-line mounting or submersion mounting with probe holder\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI1000-web\"\u003eHI1000 Series Process Digital pH Probe\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871462490481,"sku":"HI1002\/3","price":27267.3,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi10000_fertigation_irrigation_control_system.jpg?v=1792646992"}],"url":"https:\/\/hannainst.in\/collections\/probes-process-control.oembed","provider":"hanna","version":"1.0","type":"link"}