{"title":"Stock Clearance","description":"\u003cp\u003eProducts shown on the Stock Clearance page (\/pages\/stock-clearance). Add or remove products here.\u003c\/p\u003e","products":[{"product_id":"blackstone-2-9-l-h-chemical-dosing-pump-bl3","title":"Blackstone 2.9 L\/h Chemical Dosing Pump -BL3-2","description":"\u003ch5\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the\u003cbr\u003epercentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL3-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 2.9 L\/h Chemical Dosing Pump -BL3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e 250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 2.9 lph (0.8 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 8 bar (116 psi), dosing frequency strokes per min : 120\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e Diaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL3-1\"\u003eBlackstone 2.9 L\/h Chemical Dosing Pump -BL3\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162564977,"sku":"BL3-2","price":31306.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_9.jpg?v=1792645800"},{"product_id":"blackstone-7-6-l-h-chemical-dosing-pump-bl7","title":"Blackstone 7.6 L\/h Chemical Dosing Pump -BL7-2","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/dosing_pump-page-001.jpg\" alt=\"dosing pump flow rate\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSimple Operation\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps are equipped with a single control for pump output. The external flow rate control (potentiometer) on the face of the pump allows you to adjust the percentage of flow from 0 to 100% of the pump's rated capacity. This feature eliminates the need to worry about stroke lengths and power settings. An LED indicator lights up each time a stroke begins,  allowing the user to assess the stroke rate from a distance.\u003c\/p\u003e\n\u003ch5\u003eHigh Quality Materials\u003c\/h5\u003e\n\u003cp\u003eBlackStone pumps have been manufactured with the highest level of mechanical precision from materials chosen for their inherent ability to resist the effects of aggressive chemicals. When you select a Blackstone pump,  you are eliminating the time consuming effort involved in picking the right material for your application.\u003cbr\u003eBlackstone pumps are supplied with the highest quality material as standard equipment—not optional. The diaphragm utilizes one-piece construction of PTFE,  which unlike conventional laminated diaphragms,  will stand up to the test of time and wear. Ball valves are constructed in glass. The pumphead and O-rings are made of PVDF,  PTFE and FPM\/FKM which offer unsurpassed resistance. The chemical resistance chart (right) shows how well PVDF and PTFE stand up to some of the most aggressive chemicals.\u003c\/p\u003e\n\u003ch5\u003eRugged Design\u003c\/h5\u003e\n\u003cp\u003eBlackstone pumps are completely sealed during assembly and offer IP65 protection against splashes and spills providing excellent protection even in hostile environments. The fiberreinforced polypropylene housing stands up to aggressive chemicals while offering superior strength under tough industrial conditions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL7-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Blackstone 7.6 L\/h Chemical Dosing Pump -BL7\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e approximately 200 W\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Current Protection\u003c\/td\u003e\n\u003ctd\u003e 250V fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum Flow Rate\u003c\/td\u003e\n\u003ctd\u003e 7.6 LPH (2.0 gph)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Casing\u003c\/td\u003e\n\u003ctd\u003e fibre-reinforced polypropylene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e Diaphram in PTFE (PolyTetraFluoro-Ethylene), glass ball valves and O-rings in Viton® polyethylene 5 x 8 mm tubing and 1\/4 in. injection fitting\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pumphead Materials\u003c\/td\u003e\n\u003ctd\u003e pumphead in PVDF (PolyVinyliDene Fluoride),\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSelf Priming\u003c\/td\u003e\n\u003ctd\u003e maximum self-priming height is 1.5 m (5 ft.).\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 110\/115 VAC, 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 194 x 121 mm (6.5 x 7.6 x 4.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e approx. 3 kg (6.6 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL7-1\"\u003eBlackstone 7.6 L\/h Chemical Dosing Pump -BL7\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162696049,"sku":"BL7-2","price":31306.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl3_blpump_1_2.jpg?v=1792645803"},{"product_id":"conductivity-mini-controller-0-1999-s-cm-115-230vac-bl983313-1","title":"Conductivity Mini Controller (0 - 1999 µS\/cm) 115\/230VAC - BL983313-1","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313_angle.jpg\" alt=\"BL983313\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983313 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313_rear.jpg\" alt=\"BL983313\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983313 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983313-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity Mini Controller (0 - 1999 µS\/cm) 115\/230VAC - BL983313-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026gt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983313-1 (115\/230 VAC) and BL983313-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983313-1\"\u003eConductivity Mini Controller (0 - 1999 µS\/cm) 115\/230VAC - BL983313-1\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162794353,"sku":"BL983313-1","price":30438.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983313-mini-ec-controller__38724.webp?v=1794905221"},{"product_id":"universal-process-controller-hi510","title":"Universal Process Controller - HI510 - HI510-0540","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHI510 is an advanced universal process controller that can be configured for many applications requiring monitoring and\/or control of process parameters. It features a digital probe input that will automatically detect and update the controller with the parameter that it measures.\u003c\/p\u003e\n\u003cp\u003eThis controller can be configured with up to 5 control relays and 4 analog outputs. The control relays can be programmed for on\/off, Proportional, or PID (Proportional Integral Derivative) types of control or used for programming cleaning sequences triggered by a digital input or based on a schedule. The scalable analog outputs can be used for remote devices including Chart recorders, PLC, or SCADA. The analog outputs can be used for control devices including dosing pumps and valves that accept a 0\/4-20 mA output.\u003c\/p\u003e\n\u003cp\u003eHI510 features a RS485 digital output that allows up to 32 devices to be connected to a single line that can be viewed and programmed remotely using the HI92500 software. The HI92500software provides for graphic user interface that allows for settings to be changed and saved for transfer to another HI510 controller.\u003c\/p\u003e\n\u003cp\u003eThe HI510 NEMA 4X enclosure uses sealed cable glands to maintain waterproof integrity. The versatile mounting kits allow for mounting the HI510 to a wall, pipe and panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI510-display.gif\" alt=\"HI510 front\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGeneral Design Features\u003c\/h4\u003e\n\u003ch4\u003eBacklit Dot Matrix LCD with LED indicators\u003c\/h4\u003e\n\u003cp\u003eLarge backlit LCD with visual indicators for meter status, alarm and relay activation.\u003c\/p\u003e\n\u003ch4\u003eNEMA 4X Enclosure\u003c\/h4\u003e\n\u003cp\u003e½ DIN NEMA 4X enclosure suitable for outside and industrial environments.\u003c\/p\u003e\n\u003ch4\u003eVersatile Mounting Options\u003c\/h4\u003e\n\u003cp\u003eChoose from wall, pipe or panel mounted options.\u003c\/p\u003e\n\u003ch2\u003eUSB-C Connectivity\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/510_USBC.jpg\" alt=\"\" width=\"85\" height=\"60\" loading=\"lazy\" style=\"display: inline-block; max-width: 100%; height: auto; border: 0;\"\u003e\u003c\/p\u003e\n\u003ch4\u003eFlash Drive Compatible\u003c\/h4\u003e\n\u003cp\u003eTransfer of logged data and events to a flash drive as a .csv file for review on Window’s, OS X, or Linux based computers.\u003c\/p\u003e\n\u003ch4\u003eLogged Data\u003c\/h4\u003e\n\u003cp\u003eStore information at selectable intervals along with relay control settings and calibrations data. Information can be stored in up to 100 lots, each holding 8600 records.\u003c\/p\u003e\n\u003ch4\u003eEvent Management System\u003c\/h4\u003e\n\u003cp\u003eLogged events includes any changes made, alarm, error and warning activations, and calibration information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI510-2Analog-DoorOpen-ClosedRelay.jpg\" alt=\"HI510 low voltage connections\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLow Voltage Connections\u003c\/h4\u003e\n\u003ch4\u003eIsolated High Voltage Section\u003c\/h4\u003e\n\u003cp\u003eTo reduce the risk to shock the low voltage connection area is isolated from high voltage area.\u003c\/p\u003e\n\u003ch4\u003eRS485 Digital Connectivity\u003c\/h4\u003e\n\u003cp\u003eRS485 output for connecting up to 32 devices for remote monitoring and programming.\u003c\/p\u003e\n\u003ch4\u003eDigital Inputs and Analog Outputs\u003c\/h4\u003e\n\u003cp\u003eDigital probe input, digital trigger inputs, and analog outputs utilize extractable terminal blocks for simplified wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/510_open_Fuse-Panel.jpg\" alt=\"HI510 high voltage connections\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHigh Voltage Connections\u003c\/h4\u003e\n\u003ch4\u003eReplaceable Slow Blow Fuses\u003c\/h4\u003e\n\u003cp\u003eAll relays and the line power input are protected by replaceable 5A slow blow fuses.\u003c\/p\u003e\n\u003ch4\u003eSPDT and SPST Programmable Relays\u003c\/h4\u003e\n\u003cp\u003eUp to 5 relays that can be programmed for control or washing sequences.\u003c\/p\u003e\n\u003ch4\u003eFail Safe Alarm Technology\u003c\/h4\u003e\n\u003cp\u003eFail Safe Alarm Technology that deactivates relay from normal open state to normally closed to supply power to remote alarm device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/setpoint2.jpg\" alt=\"HI510 Programming Options\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eProgramming HI510 remotely using HI92500 Software\u003c\/h2\u003e\n\u003ch4\u003eRelay Control Modes\u003c\/h4\u003e\n\u003cp\u003eSet points for control operations can be configured to be on\/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.\u003c\/p\u003e\n\u003ch4\u003eConfigurable Alarm System\u003c\/h4\u003e\n\u003cp\u003eConfigurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.\u003c\/p\u003e\n\u003ch4\u003eAuto-cleaning cycle\u003c\/h4\u003e\n\u003cp\u003eThe cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.\u003c\/p\u003e\n\u003ch4\u003eScalable Analog Outputs\u003c\/h4\u003e\n\u003cp\u003eAnalog outputs can be scaled to assign 0 to 20 mA or 4-20 mA to a specific range for increased resolutions. Analog outputs can be programmed to send 22 mA signal when placed in hold status during maintenance including calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eUniversal Process Controller - HI510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003eon\/off, proportional and PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Terminals\u003c\/td\u003e\n\u003ctd\u003eUp to 5 relays (independently configurable for process variables, Hold \u0026amp; Cleaning functions)\nElectromechanical relay SPDT and SPST contact outputs\n5A – 250 Vac; 5A – 30 Vdc (resistive load)\nFuse protected: 5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003eUp to 5 relays (independently configurable for process variables, Hold \u0026amp; Cleaning functions)\n\nElectromechanical relay SPDT and SPST contact outputs\n5A – 250 Vac; 5A – 30 Vdc (resistive load)\nFuse protected: 5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Error\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e2 or 4 independent, galvanically isolated outputs\n0 – 22 mA configurable as:\n0 – 20 mA; 4 – 20 mA\n22 mA as alarm signal, configurable option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003eindependent, galvanically isolated inputs (configurable for Hold \u0026amp; Cleaning functions)\nOn state: 5 to 24 Vdc, low or high level active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Signal\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e*Single case ½ DIN, type NEMA4X, IP65 ingress protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Cutout\u003c\/td\u003e\n\u003ctd\u003e1\/2 DIN (brackets ordered seperately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eone digital input with RS485 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI10X6 series – pH and Temperature (ordered seperately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003eHI20X4 series – ORP and Temperature (ordered seperately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eInterval log, up to 100 files, maximum 8600 records on each stored file.\nWhen the maximum limit of 100 stored files is reached, the most recent file will automatically erase the oldest one.\nEvent log, maximum 100 records. When the maximum limit i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eRS485 serial port - Remote monitoring and control\nUSB-C port - Retrieve log files and firmware upgrading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Timeout Reminder\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003eup to 4 based on configuration ordered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD, 128 x 64 pixel B\/W with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 – 240 Vac ±10%; 50\/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 144.0 mm (5.7 in.) x Height 144.0 mm (5.7 in.) x Depth 151.3 mm (6.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.6 kg (3.5 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e*For a water tight seal, tighten the front four screws on the front casing to 13.3 lbf·in (1.5 N·m, maximum 2.0 N·m), of torque.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI510\" target=\"_blank\" rel=\"noopener\"\u003eUniversal Process Controller - HI510\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871164924273,"sku":"HI510-0540","price":150950.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/510_front_1_5.jpg?v=1792645805"},{"product_id":"tds-mini-controller-0-0-to-199-9-ppm-bl983315-2-230-vac-output-4-20-ma","title":"TDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 230 VAC,  Output: 4-20 mA","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThis compact, panel mounted, process controller is ideal for measuring total dissolved solids (TDS) of a process stream. This controller features a large LCD with protective cover. Users may choose from automatic or manual dosing modes.\u003c\/p\u003e\n\u003cp\u003eWhen in automatic mode, the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983315 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_angle.jpg\" alt=\"BL983315\" width=\"500\" height=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_rear.jpg\" alt=\"BL983315\" width=\"500\" height=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003cp\u003eBL983315 uses a 0.5 conversion factor in which 1.0 µS\/cm = 0.5 ppm.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel available with 4-20 mA galvanic isolated output with external dosing disable contact\u003c\/li\u003e\n\u003cli\u003eLarge Clear LCD\u003c\/li\u003e\n\u003cli\u003eFire Retardant Casing\u003c\/li\u003e\n\u003cli\u003eSplash-Resistant Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" width=\"600\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL983315-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 230 VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 199.9 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 12 VDC adapter (included)\nmodels “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL983315-2\" target=\"_blank\" rel=\"noopener\"\u003eTDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 115\/230 VAC, Output: 4-20 mA\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166038385,"sku":"BL983315-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315-2.png?v=1792645812"},{"product_id":"conductivity-mini-controller-0-00-10-00-ms-cm-bl983317-12vdc","title":"Conductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-12VDC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317_angle.jpg\" alt=\"BL983317\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983317 features a dosing relay that is activated when the reading is below a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is above the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is below the set point and the relay is active.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317_rear.jpg\" alt=\"BL983317\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7632.jpg\" alt=\"HI7632\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983317 mini controller uses the \u003cstrong\u003eHI7632\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7632 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983317-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-12VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 10.00 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 10 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983317-0 (12 VDC) and BL983317-1 (115\/230 VAC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983317-1\"\u003eConductivity Mini Controller (0.00-10.00 mS\/cm) - BL983317-12VDC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166103921,"sku":"BL983317-1","price":22547.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983317-Conductivity-Mini-Controller-0.00-10__54457.webp?v=1794905122"},{"product_id":"tds-mini-controller-0-to-1999-ppm-bl983319-1-115-230vac","title":"TDS Mini Controller (0 to 1999 ppm) - BL983319-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983319_angle.jpg\" alt=\"BL983319\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983319 features a dosing relay that is activated when the reading is below a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983319_rear.jpg\" alt=\"BL983319\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983319 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983319-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0 to 1999 ppm) - BL983319-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 1999 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 1999 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983319-1 (115\/230 VAC) and BL983319-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983319-1\"\u003eTDS Mini Controller (0 to 1999 ppm) - BL983319-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166366065,"sku":"BL983319-1","price":30438.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl983319-tds-controller-0-to-1999-ppm__34542.webp?v=1794904815"},{"product_id":"tds-mini-controller-0-00-to-19-99-ppm-bl983321-115-230vac","title":"TDS Mini Controller (0.00 to 19.99 ppm) - BL983321-115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983321_angle.jpg\" alt=\"BL983321\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983321 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983321_rear.jpg\" alt=\"BL983321\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983321 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983321-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0.00 to 19.99 ppm) - BL983321-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 19.99 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 19.99 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983321-1 (115\/230 VAC) and BL983321-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983321-1\"\u003eTDS Mini Controller (0.00 to 19.99 ppm) - BL983321-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871168659825,"sku":"BL983321-1","price":22547.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl983321_front___56514.webp?v=1794907282"},{"product_id":"conductivity-controller-0-00-to-19-99-s-cm-bl983322-1-115-230vac","title":"Conductivity Controller (0.00 to 19.99 µS\/cm) - BL983322-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983322_angle.jpg\" alt=\"BL983322\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983322 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983322_rear.jpg\" alt=\"BL983322\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983322 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003ch4\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003ch4\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983322-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity Controller (0.00 to 19.99 µS\/cm) - BL983322-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e  ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 19.99 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983322-1 (115\/230 VAC) and BL983322-0 (12 VDC) supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983322-1\"\u003eConductivity Controller (0.00 to 19.99 µS\/cm) - BL983322-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871168692593,"sku":"BL983322-1","price":30438.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl983322_front__41994.webp?v=1794904658"},{"product_id":"tds-mini-controller-0-to-999-ppm-bl983329-1-115-230vac","title":"TDS Mini Controller (0 to 999 ppm) - BL983329-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983329_angle.jpg\" alt=\"BL983329\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983329 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983329_rear.jpg\" alt=\"BL983329\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983329 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983329-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e TDS Mini Controller (0 to 999 ppm) - BL983329-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 999 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F) with β =2%\/oC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e 0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 999 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026gt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983329-1 (115\/230 VAC) and BL983329-0 (12 VDC) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983329-1\"\u003eTDS Mini Controller (0 to 999 ppm) - BL983329-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871170527601,"sku":"BL983329-1","price":30438.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bl983329_front__23871.webp?v=1794907371"},{"product_id":"refillable-double-junction-ph-electrode-with-bnc-pin-connector-hi1043p","title":"Refillable Double Junction pH Electrode with BNC + Pin Connector - HI1043P","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH,  bulb shape,  body material,  type of junction,  type of reference and electrolyte used are just some of the design considerations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe HI1043P uses high temperature (HT) glass,  spherical bulb,  glass body,  single ceramic frit,  double junction and is refillable with 3.5M KCl.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC214D_HTGlass.png\" alt=\"high temperature glass\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHigh Temperature Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eThe measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25℃ while the resistance of HT glass is around 400 megaohms at 25℃. As the HI1043P is used at elevated temperatures the resistance decreases and approaches the resistance of GP glass. The HI1043P is suitable to use with samples that measure from 0 to 100℃.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/high_temperature_glass.png\" alt=\"high temperature glass\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSpherical Bulb\u003c\/h4\u003e\n\u003cp\u003eThe spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/glass-body-bfa9885d.png\" alt=\"glass body\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGlass Body\u003c\/h4\u003e\n\u003cp\u003eThe glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allow for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/singleceramic_double_junction.png\" alt=\"double junction reference\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSingle Ceramic Double Junction Reference\u003c\/h4\u003e\n\u003cp\u003eThe HI1043P is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction also known as a salt bridge is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL\/hour. Other junction types are available with higher flow rates and made with different materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/refillable.png\" alt=\"refillable\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eRefillable\u003c\/h4\u003e\n\u003cp\u003eThe HI1043P is a refillable probe. Since it is a double junction pH electrode the fill solution is the HI7082 3.5M KCl. This solution does not contain any silver as with single junction electrode. The absence of silver will prevent any silver precipitate from forming at the junction surface and clogging it. Clogging of the junction will result in drifty and erratic readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1043D_DinplusPin.png\" alt=\"bnc + pin connector\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBNC + Pin Connector\u003c\/h4\u003e\n\u003cp\u003eThe HI1043P has a BNC and pin connector. The BNC connector is universal in that it can be used on any pH meter that has the female BNC probe input. The pin connector is used to enable the CAL Check function on the following benchtop pH meters; HI122,  HI123,  HI221,  HI222,  HI223,  HI2221,  HI2222,  and HI2223.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/electrode_fill_solutions_comparison.png\" alt=\"junction types\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eSingle Junction Versus Double Junction pH Electrodes\u003c\/h2\u003e\n\u003cp\u003eConventional electrodes are normally single junction. As depicted by the figure above,  these electrodes have only a single junction between the internal refernce wire and the external solution. Under adverse conditions,  such as high pressure,  high temperature,  highly acidic or alkaline solutions,  the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked,  the reference electrode can become contaminated,  leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample,  some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.\u003c\/p\u003e\n\u003cp\u003eHanna's double junction system,  as the name implies,  has two junctions,  only one of which is in contact with the sample as shown in the figure. Under adverse conditions,  the same tendency of sample ingress is evident. However,  as the reference electrode system is separated physically from the intermediate electrolyte area,  the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is \"silver-free\". Since there is no silver present,  there is no precipitate that can form to clog the junction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI1043P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Refillable Double Junction pH Electrode with BNC + Pin Connector - HI1043P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e pH: 0 to 14\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e ceramic, single \/ 15-20 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd\u003e 3.5M KCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e spheric (dia: 9.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 100°C (32 to 212°F) - HT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 175.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC + pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e high conductivity samples, hydrocarbon, paints, sea water, solvents, strong acid and base, tris buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871192187249,"sku":"HI1043P","price":25111.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1043_3.jpg?v=1792645852"},{"product_id":"professional-benchtop-ph-mv-meter-with-built-in-printer-hi122","title":"Professional Benchtop pH\/mV Meter with Built-in Printer - HI122-02","description":"\u003cp\u003eThe HI122 pH\/mV and temperature benchtop meter features CAL Check™,  a clear and informative LCD display,  data logging capability,  and computer connectivity. The HI122 has a single input channel that allows for measurement of pH and ORP. Readings for pH can be manually or automatically compensated for temperature variations with the separate HI7662-T temperature probe from -20.0 to 120.0℃.\u003c\/p\u003e\n\u003cp\u003eThe HI122 can be calibrated up to five points with a choice of seven standard buffers or two custom buffers. All GLP data regarding pH and relative mV calibration is stored for the user to review when necessary. The built-in impact printer incorporated into the HI122 allows for on demand printing of a complete set of information based on the measured,  set or recorded data while in various modes such as,  measurement mode,  GLP or Setup mode.\u003c\/p\u003e\n\u003ch5\u003eFeatures at-a-glance\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eCAL Check™\u003c\/strong\u003e - Hanna's exclusive CAL Check™ diagnostics system ensures accurate pH readings every time by alerting users of potential problems during the calibration process. The CAL Check™ system eliminates erroneous readings due to dirty or faulty pH electrodes or contaminated pH buffer solutions during calibration. After the guided calibration process,  the probe condition is evaluated and an indicator is displayed informing the user of the overall pH electrode status.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003e\u003cstrong\u003eAutomatic Calibration\u003c\/strong\u003e - \u003c\/strong\u003epH calibration can be performed up to five points with seven standard buffers and two custom buffers.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBuilt-in Impact Printer\u003c\/strong\u003e - The built-in impact printer incorporated into the HI122 uses regular paper that does not fade with time. The information related to measurements being taken can be printed while in measurement mode,  GLP or Setup mode. This meter also allows users to print detailed information in four languages for specific help screens and instrument set-up.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHI1131P pH Electrode\u003c\/strong\u003e - The HI122 is supplied with the HI1131P glass body,  double junction,  refillable pH electrode with an indicating sensor made of High Temperature (HT) glass. The double junction and HT glass design allows the HI1131P to be used in a wide variety of applications ranging from samples with metals and Tris buffer to samples at elevated temperatures.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e - Temperature for pH measurements can be compensated for automatically (ATC) or manually (MTC) from -20.0 to 120.0℃ with the use of the supplied HI7662-T temperature probe.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGLP Data\u003c\/strong\u003e - The calibration data for each channel including date,  time,  standards used,  offset,  and slope can be accessed at any time through the HI122 menu.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e - The log-on-demand feature accepts the recording of 50 samples. Interval logging allows up to 1000 data points to be recorded and allows the user to specify time intervals from 5 seconds to 180 minutes.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Transfer\u003c\/strong\u003e - With a built-in logging function,  measurements are stored in non-volatile memory,  and can be transferred to a PC through the RS232 port.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI122-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Professional Benchtop pH\/mV Meter with Built-in Printer - HI122\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e -2.00 to 16.00 pH, -2.000 to 16.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH, 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH, ±0.002 pH (@25ºC\/77ºF)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e automatic, up to five-point calibration with seven standard buffers available (1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45) and two custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic or manual from -20.0 to 120.0 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e ±999.9 mV; ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mV; 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.2 mV (±699.9 mV); ±0.5 mV (±999.9 mV); ±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Relative Offset\u003c\/td\u003e\n\u003ctd\u003e ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e -20.0 to 120.0 ºC, -4.0 to 248.0 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C (0.1°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.4°C (±0.7°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e HI1131P pH electrode (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Probe\u003c\/td\u003e\n\u003ctd\u003e HI7662-T temperature probe (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003e log-on-demand; interval\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e 50 samples (25 per channel); 1000 samples (500 per channel)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Interval\u003c\/td\u003e\n\u003ctd\u003e 5 seconds to 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e RS232 serial port, opto-isolated\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter\u003c\/td\u003e\n\u003ctd\u003e built-in dot matrix printer, with 44 mm plain paper\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 12 VDC adapter (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F), RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 280 x 203 x 84 mm (11.0 x 8.0 x 3.3”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1.9 kg (4.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI122 is supplied with HI1131P pH electrode, HI7662-T temperature probe, HI70004 pH 4.01 buffer solution sachet, HI70007 pH 7.01 buffer solution sachet, HI7082 3.5M KCl electrolyte solution (30 mL), (5) paper rolls, 12 VDC adapter and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI122-01\"\u003eProfessional Benchtop pH\/mV Meter with Built-in Printer - HI122\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871200280945,"sku":"HI122-02","price":176189.85,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi122_2.jpg?v=1792645872"},{"product_id":"platinum-orp-half-cell-electrode-with-bnc-connector-hi3133b","title":"Platinum ORP Half-Cell Electrode with BNC Connector - HI3133B","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHanna Instruments offers a wide variety of ORP electrodes that are designed for many different applications. The type of material used for the sensing pin,  type of glass used for body material,  type of junction,  type of reference and electrolyte used are just some of the design considerations.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI3133_platinumpin.png\" alt=\"Platinum Pin\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eThe HI3133B uses a platinum pin and glass body.\u003c\/h4\u003e\n\u003ch5\u003ePlatinum Sensing Pin\u003c\/h5\u003e\n\u003cp\u003eThe HI3133B ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange,  a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body,  and together with the reference signal is conducted to the measurement meter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI3133_glassbody.png\" alt=\"Glass Body\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGlass Body\u003c\/h4\u003e\n\u003cp\u003eThe glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the equilibrium the steadier the reference potential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bnc.png\" alt=\"BNC connector\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBNC Connector\u003c\/h4\u003e\n\u003cp\u003eThe HI3133B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN,  screw type,  T-type,  and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3133B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Platinum ORP Half-Cell Electrode with BNC Connector - HI3133B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e platinum pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e -5 to 100°C (23 to 212°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 163.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e general purpose, potentiometric titration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871248843121,"sku":"HI3133B","price":22748.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3133.jpg?v=1792645935"},{"product_id":"pretreatment-oxidizing-solution-230-ml-hi7092m","title":"Pretreatment oxidizing solution (230 mL) - HI7092M","description":"\u003cp\u003ePretreatment oxidizing solution,  230 mL\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7092M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7092M Pretreatment oxidizing solution (230 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e oxidizing pretreatment solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7092M\"\u003eHI7092M Pretreatment oxidizing solution (230 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871251235185,"sku":"HI7092M","price":2297.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7092m_box.jpg?v=1792645942"},{"product_id":"cleaning-solution-for-wine-deposits-500-ml-hi70635l","title":"Cleaning Solution for Wine Deposits (500 mL) - HI70635L","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note,  because during calibration,  the instrument assumes that the electrode is clean and that the standardization curve created duringthe calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-01-08_at_3.20.38_PM.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI70635L is a cleaning solution made specifically for the wine industry,  where electrodes can become coated with wine particulates and deposits found in juice and must.\u003c\/p\u003e\n\u003ch4\u003eAir tight bottle with tamper-proof seal\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eEach bottle marked with lot number and expiration date\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70635L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI70635L Cleaning Solution for Wine Deposits (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e cleaning solution for wine deposits (winemaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70635L\"\u003eHI70635L Cleaning Solution for Wine Deposits (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871251300721,"sku":"HI70635L","price":4053.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70635l_1.jpg?v=1792645944"},{"product_id":"cleaning-solution-for-wine-stains-500-ml-hi70636l","title":"Cleaning Solution for Wine Stains (500 mL) - HI70636L","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eThe most common cause for pH measurement inaccuracies is an unclean or improperly cleaned electrode. This is very important to note,  because during calibration,  the instrument assumes that the electrode is clean and that the standardization curve created duringnthe calibration process will remain a valid reference until the next calibration. pH meters on the market today will allow an offset voltage of approximately ±60 mV. The deviation from 0 mV is not unusual but ideally should be no greater than ±30 mV. The calibration process compensates for the change in offset voltage. If the mV offset continues to deviate and the meter is calibrated with a dirty electrode then inaccurate readings will result.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-01-08_at_3.20.38_PM.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eThe Cleaning Solution Series ensures maximum efficiency and accuracy of your sensors when used for it’s designated application. Cleaning is a fast and effective routine that should be performed on a regular basis as a preventative measure against using a dirty electrode and to ensure that the junction is not clogged. The HI70636L is a cleaning solution made specifically for the wine industry,  where electrodes can become stained by wine juice and must.and must.\u003c\/p\u003e\n\u003ch4\u003eAir tight bottle with tamper-proof seal\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eEach bottle marked with lot number and expiration date\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna cleaning solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70636L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI70636L Cleaning Solution for Wine Stains (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e cleaning solution for wine stains (winemaking)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70636L\"\u003eHI70636L Cleaning Solution for Wine Stains (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871251366257,"sku":"HI70636L","price":4053.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70636l_1.jpg?v=1792645944"},{"product_id":"ammonia-test-kit-for-fresh-water-with-checker-disc-hi38049","title":"Ammonia Test Kit for Fresh Water with Checker Disc - HI38049","description":"\u003cp\u003eThe HI38049 is a colorimetric chemical test kit that determines the ammonia concentration in fresh water within a 0.0 to 3.0 mg\/L (ppm) range as NH\u003csub\u003e3\u003c\/sub\u003e-N. The HI38049 is supplied with all of the necessary reagents and equipment to perform the analysis. The included Checker® disc makes concentration determination more accurate and easier than a typical color comparator. The test kit contains enough reagents for perform 100 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the sample beaker,  color comparison cube,  and reagent dropper bottles.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eReadings from 0.0 to 3.0 mg\/L NH\u003csub\u003e3\u003c\/sub\u003e-N are determined to 0.1 mg\/L resolution.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI38049-100 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 1 (20mL) dropper bottle of Ammonia Reagent 1 and 1 (20 mL) dropper bottle Nessler reagent.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSignificance of Use\u003c\/h4\u003e\n\u003cp\u003eGroundwater normally contains ammonia due to bacterial decay of plants and animals. However,  concentrations of ammonia in rivers and drinking water reservoirs may indicate the presence of agricultural runoff or urban pollution. When the concentration of ammonia is high enough,  it can alter the smell and taste of water. In industrial applications,  high concentrations of ammonia can cause corrosion in pipes. Ammonia is also monitored in fresh water aquariums and fish farming applications because of its toxicity to fish.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI38049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia Test Kit for Fresh Water with Checker Disc - HI38049\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Measurement Type\u003c\/td\u003e\n\u003ctd\u003e Checker Disc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 3.0 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003e Nessler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 248 g (8.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165x150x38 mm (6.5x5.9x1.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI38049 test kit comes with 1 (20mL) dropper bottle of Ammonia Reagent 1, 1 (20 mL) dropper bottle Nessler Reagent, 1 checker disc, 2 glass vials with caps, and 1 (3mL) plastic pipette.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI38049\"\u003eAmmonia Test Kit for Fresh Water with Checker Disc - HI38049\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871255855473,"sku":"HI38049","price":11670.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi38049_1.jpg?v=1792645962"},{"product_id":"ammonia-test-kit-for-fresh-water-replacement-reagents-100-tests-hi38049-100","title":"Ammonia Test Kit for Fresh Water Replacement Reagents (100 tests) - HI38049-100","description":"\u003cp\u003eThe HI38049-100 are high-quality reagents that are pre-measured,  allowing for users to achieve fast and accurate ammonia measurements with the HI38049 chemical test kit. These reagents follow the Nessler method to determine fresh water ammonia concentration as ammonia-nitrogen (NH\u003csub\u003e3\u003c\/sub\u003e-N).\u003c\/p\u003e\n\u003cp\u003eFor determination of ammonia,  the Nessler reagent is added to the sample under alkaline conditions to react with ammonia. The reaction between ammonia and the mercury-containing reagent causes a yellow colored complex to form; the greater the concentration,  the deeper the color. A Checker disc is included for an accurate,  side-by-side,  visual analysis to determine ammonia concentration. These reagents are designed to be used with samples that have an expected ammonia range of 0.0 to 3.0 mg\/L (ppm) NH\u003csub\u003e3\u003c\/sub\u003e-N.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI38049-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia Test Kit for Fresh Water Replacement Reagents (100 tests) - HI38049-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e Nessler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI38049-100\"\u003eAmmonia Test Kit for Fresh Water Replacement Reagents (100 tests) - HI38049-100\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871255888241,"sku":"HI38049-100","price":2807.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi38049-100.jpg?v=1792645962"},{"product_id":"ph-test-kit-hi38058","title":"pH Test Kit - HI38058","description":"\u003cp\u003eThe HI38058 is a chemical test kit that determines the pH between 4.0 and 10.0 pH units. The HI38058 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform 300 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete setup \u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the glass vials, plastic pipette, reagent bottle, and Checker® disc.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eReadings from 4.0 to 10.0 are determined to 0.5 pH unit resolution.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003c\/li\u003e\n\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI38058-100 replacement reagents can be ordered for use with this kit.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eSignificance of Use\u003c\/h4\u003e\n\u003cp\u003epH represents acidity or alkalinity of an aqueous solution and is proportional to the hydrogen-ion concentration of the solution. Under neutral conditions water is dissociated into the OH\u003csup\u003e-\u003c\/sup\u003e and H\u003csup\u003e+\u003c\/sup\u003e ions in equal ratio and hence it has a pH of 7. When bases or acids are added to a water solution they ionize, increasing the concentration of OH\u003csup\u003e-\u003c\/sup\u003e or H\u003csup\u003e+\u003c\/sup\u003e, respectively. Thus solutions with a pH of 1-3 contain strong acids, whereas those with a pH of 4-6 contain weak acids. Weak bases result in solutions of pH 8-10 and strong bases in pH of 11-13. HI38058-0 reagent reacts in contact with the aqueous solution changing its color according to the hydrogen-ion concentration (pH) in the given range.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI38058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003epH Test Kit - HI38058\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Measurement Type\u003c\/td\u003e\n\u003ctd\u003eChecker Disc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e4.0 to 10.0 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.5 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Number of Tests\u003c\/td\u003e\n\u003ctd\u003e300\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e215 g (7.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e165x150x38 mm (6.5x5.9x1.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI38058 test kit comes with 1 dropper bottle (30mL) pH wide range indicator, checker disc, glass vials with caps (2), and a 3 mL plastic pipette.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI38058\" target=\"_blank\" rel=\"noopener\"\u003epH Test Kit - HI38058\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871256183153,"sku":"HI38058","price":11078.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi38058_1.jpg?v=1792645967"},{"product_id":"backpack-lab-water-quality-educational-test-kit-hi3817bp","title":"Backpack Lab Water Quality Educational Test Kit - HI3817BP","description":"\u003cp\u003eThe HI3817BP is a classroom in a backpack! The Backpack Lab Water Quality Educational Test Kit contains lessons, activities, and test kits to help students understand the importance of common water quality parameters. Using titration, colorimetry, and direct measurement, educators and students can easily measure parameters such as acidity, alkalinity, carbon dioxide, dissolved oxygen, hardness, pH, EC, TDS, and turbidity. The HI3817BP is supplied with all of the necessary reagents and equipment to perform each analysis, and all reagents and buffers are individually available as they run out. Hanna chemical test kits and pocket testers included in this Backpack Lab provide teachers with a valuable tool in helping students assess the water quality of streams, rivers, and lakes.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTests for ten important water quality parameters\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eClassrooms can gain an extensive understanding of water quality through measurement of these ten parameters:\nAcidity, alkalinity, carbon dioxide, dissolved oxygen, hardness, nitrate, phosphate, pH, EC, and TDS.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete testing setup\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit, such as the pH tester, sample beaker, indicator and reagent bottles and packets, and glass bottle for dissolved oxygen.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eHigh resolution\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll tests provide a high resolution based on the expected range of measurement.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents and buffers for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive educational material\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThe lesson plan and components are tied together by a comprehensive teacher's manual that includes information about each parameter, classroom activities designed to introduce students to each parameter, and detailed field-testing procedures.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI3817BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eBackpack Lab Water Quality Educational Test Kit - HI3817BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 2000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic, one point at 1382 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003emodified Winkler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5°C \/ 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 500 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 5 mg\/L (0 to 500 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Method\u003c\/td\u003e\n\u003ctd\u003emethyl orange \/ phenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAcidity Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 100 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L (0 to 100 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein \/ bromophenol blue\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Number of Test\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L CO₂; 0.0 to 50.0 mg\/L CO₂; 0 to 100 mg\/L CO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (0.0 to 10.0 mg\/L range); 0.5 mg\/L (0.0 to 50.0 mg\/L range); 1 mg\/L (0 to 100 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Method\u003c\/td\u003e\n\u003ctd\u003ephenolphthalein\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCarbon Dioxide Number of Tests\u003c\/td\u003e\n\u003ctd\u003e110\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Measurement Type\u003c\/td\u003e\n\u003ctd\u003etitration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L CaCO₃; 0 to 300 mg\/L CaCO₃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e0.3 mg\/L (0.0 to 30.0 mg\/L range); 3 mg\/L (0 to 300 mg\/L range)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eEDTA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 50 mg\/L NO₃⁻-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e10 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003ecadmium reduction\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Number of Tests\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Measurement Type\u003c\/td\u003e\n\u003ctd\u003ecolorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 5 mg\/L PO₄³⁻\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Number of Test\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3817BP Backpack Lab includes HI98129 Combo pH\/EC\/TDS\/temperature tester, acidity test kit, alkalinity test kit, carbon dioxide test kit, dissolved oxygen test kit, hardness test kit, nitrate test kit, phosphate test kit, set of 10 field test procedures, teacher's resource CD, teacher's guide and backpack.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI3817BP\" target=\"_blank\" rel=\"noopener\"\u003eBackpack Lab Water Quality Educational Test Kit - HI3817BP\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871261720945,"sku":"HI3817BP","price":74683.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3817bp-water-backpack-lab_1200x1200_300_rgb.jpg?v=1792645980"},{"product_id":"ammonia-test-kit-for-seawater-hi3826","title":"Ammonia Test Kit for Seawater - HI3826","description":"\u003cp\u003eThe HI3826 is a colorimetric chemical test kit that determines the ammonia concentration in seawater within a 0.0 to 2.5 mg\/L (ppm) range as NH\u003csub\u003e3\u003c\/sub\u003e-N. The HI3826 is supplied with all of the necessary reagents and equipment to perform the analysis. The test kit contains enough reagents for perform approximately 25 tests.\u003c\/p\u003e\n\u003ch2\u003e\n\u003cbr\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch5\u003eComplete setup\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the sample beaker,  color comparison cube,  and reagent dropper bottles.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh resolution\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eReadings from 0.0 to 2.5 mg\/L NH\u003csub\u003e3\u003c\/sub\u003e-N are determined to 0.5 mg\/L resolution.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eReplacement reagents available\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3826-025 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 1 (20mL) dropper bottle of Ammonia Reagent 1 for Seawater and 1 (20mL) dropper bottle of Nessler Reagent.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eConcentrations of ammonia in rivers,  estuaries,  and bays may indicate the presence of agricultural runoff or urban pollution. When the concentration of ammonia is high enough,  it can prove toxic to aquatic life,  affecting the survival,  growth,  and reproduction rates of various marine species. In industrial applications,  high concentrations of ammonia can cause corrosion in pipes.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ammonia Test Kit for Seawater - HI3826\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Measurement Type\u003c\/td\u003e\n\u003ctd\u003e Colorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 2.5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003e Nessler\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 180 g (6.8 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 220x145x55 mm (8.7x5.7x2.1 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3826 test kit comes with 20 mL plastic beaker, color comparison cube, 20 mL dropper bottle ammonia reagent 1 (for seawater), and 20 mL dropper bottle Nessler reagent.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3826\"\u003eAmmonia Test Kit for Seawater - HI3826\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871266996593,"sku":"HI3826","price":5243.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3826_1.jpg?v=1792645991"},{"product_id":"backpack-lab-soil-quality-educational-test-kit-hi3896bp","title":"Backpack Lab Soil Quality Educational Test Kit - HI3896BP","description":"\u003cp\u003eThe HI3896BP is a classroom in a backpack! The Backpack Lab Soil Quality Educational Test Kit contains lessons,  activities,  and test kits to help students understand the importance of common soil quality parameters. Using colorimetry,  turbidimetry,  and direct measurement,  educators and students can easily measure parameters such as nitrogen,  phosphorus,  potassium,  pH,  EC,  TDS,  and temperature. The HI3896BP is supplied with all of the necessary reagents and equipment to perform each analysis,  and all reagents and buffers are individually available as they run out.\u003c\/p\u003e\n\u003cp\u003eHanna chemical test kits and pocket testers included in this Backpack Lab provide teachers with a valuable tool in helping students address important issues related to soil quality and modern agriculture practices. Real-world examples help students understand the relevance of macronutrients and other parameters in everyday life. Teachers are able to introduce students to important chemical tests for evaluating soil quality and fertility,  and relate these measurements to the principles of plant metabolism.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eTests for seven important soil quality parameters\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eClassrooms can gain an extensive understanding of soil quality through measurement of these seven parameters: \u003cbr\u003eNitrogen,  phosphorus,  potassium,  pH,  EC,  TDS,  and temperature.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\u003cli\u003e\n\u003cstrong\u003eComplete testing setup\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the pH tester,  test tubes,  indicator and reagent bottles and packets,  and thermometer.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\u003c\/ul\u003e\n\u003cul\u003e\n\u003cli\u003e\n\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The reagents and buffers for each parameter can be ordered individually.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003cli\u003e\n\u003cstrong\u003eComprehensive educational material\u003c\/strong\u003e\u003cul\u003e\u003cli\u003eThe lesson plan and components are tied together by a comprehensive teacher's manual that includes information about each parameter,  classroom activities designed to introduce students to each parameter,  and detailed field-testing procedures.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3896BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Backpack Lab Soil Quality Educational Test Kit - HI3896BP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.05 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e automatic, one or two-point with two sets of standard buffers (pH 4.01 \/ 7.01 \/ 10.01 or 4.01 \/ 6.86 \/ 9.18)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 3999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e automatic, one point at 1413 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 2000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% F.S.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003e automatic, one point at 1382 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 60.0°C \/ 32.0 to 140.0°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C \/ 0.1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.5°C \/ 1°F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermistor Temperature Range\u003c\/td\u003e\n\u003ctd\u003e -50.0 to 220°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermistor Temperature Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1°C (-50.0 to 199.9°C); 1°C (200 to 220°C)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermistor Temperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.3°C (-20 to 90°C); ±0.4% F.S. (outside)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eThermometer Probe\u003c\/td\u003e\n\u003ctd\u003e stainless steel probe; 125 mm x dia 5 mm (4.9 x dia 0.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Measurement Type\u003c\/td\u003e\n\u003ctd\u003e colorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e traces, low, medium, high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003e Ned\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Measurement Type\u003c\/td\u003e\n\u003ctd\u003e colorimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Range\u003c\/td\u003e\n\u003ctd\u003e traces, low, medium, high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Method\u003c\/td\u003e\n\u003ctd\u003e ascorbic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous Number of Test\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Measurement Type\u003c\/td\u003e\n\u003ctd\u003e turbidimetric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Range\u003c\/td\u003e\n\u003ctd\u003e traces, low, medium, high\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Method\u003c\/td\u003e\n\u003ctd\u003e tetraphenylborate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Number of Test\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3896BP Backpack Lab test kit includes agriculture test kit pro, HI98129 Combo pH\/EC\/TDS\/temperature tester, HI145 digital thermometer, set of 6 field test procedures, teacher’s resource CD, teacher’s guide and backpack.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3896BP\"\u003eBackpack Lab Soil Quality Educational Test Kit - HI3896BP\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871272141169,"sku":"HI3896BP","price":55321.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3896bp-soil-backpack-lab.jpg?v=1792646010"},{"product_id":"nitrite-test-kit-replacement-reagents-100-tests-hi3873-100","title":"Nitrite Test Kit Replacement Reagents (100 tests) - HI3873-100","description":"\u003cp\u003eThe HI3873-100 are high quality reagents that are pre-measured,  allowing for users to achieve fast and accurate nitrite measurements with the chemical test kit. These reagents follow the chromotropic acid method to determine nitrite concentration as nitrite-nitrogen (NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N).\u003c\/p\u003e\n\u003cp\u003eFor determination of nitrite,  the chromotropic acid reagent reacts with the nitrite present in the sample causing an orange colored complex to form; the greater the concentration,  the deeper the color. A color comparator cube is included for an accurate,  side-by-side,  visual analysis to determine nitrite concentration. These reagents are designed to be used with samples that have an expected nitrite range of 0.0 to 1.0 mg\/L (ppm) NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3873-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Nitrite Test Kit Replacement Reagents (100 tests) - HI3873-100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e packets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 100 tests\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMethod\u003c\/td\u003e\n\u003ctd\u003e chromotropic acid\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3873-100\"\u003eNitrite Test Kit Replacement Reagents (100 tests) - HI3873-100\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871274828145,"sku":"HI3873-100","price":2807.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3873-100_1.jpg?v=1792646019"},{"product_id":"free-chlorine-medium-range-test-kit-hi3875","title":"Free Chlorine Medium Range Test Kit - HI3875","description":"\u003cp\u003eThe HI3875 is a chemical test kit that determines the free chlorine concentration within a 0.0 to 3.5 mg\/L (ppm) range. The HI3875 is supplied with all of the necessary reagents and equipment to perform the analysis,  including the Checker® disc for accurate determination. The test kit contains enough reagents for perform approximately 100 tests.\u003c\/p\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003ch5\u003eComplete setup\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAll required materials are included with the test kit,  such as the glass vials,  plastic pipette,  reagent packets,  and Checker® disc.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eHigh resolution\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eReadings from 0.0 to 3.5 mg\/L are determined to 0.1 mg\/L resolution\u003c\/li\u003e\u003c\/ul\u003e\n\u003cp\u003e\u003cstrong\u003eReplacement reagents available\u003c\/strong\u003e\u003cbr\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eThere is no need to buy a new kit when reagents are exhausted. The HI3875-100 reagent set can be ordered to replace the reagents supplied with the kit. This reagent set comes with 100 packets of HI93701-0 free chlorine reagent and 1 (500mL) bottle of deionized water.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch2\u003eSignificance of Use\u003c\/h2\u003e\n\u003cp\u003eDisinfection is a process of killing disease-causing organisms (or pathogens). Chlorine (Cl\u003csub\u003e2\u003c\/sub\u003e) is a very desirable disinfectant because,  when mixed with pure water,  it reacts to form hypochlorous acid (HOCl) and hydrochloric acid (HCl). HOCl (free active chlorine) is the most effective form of chlorine for disinfection of pools,  spas,  and drinking water.\u003c\/p\u003e\n\u003cp\u003eDrinking water municipalities add elemental chlorine to the water supply as chlorine gas,  liquid sodium hypochlorite,  or dry calcium hypochlorite. In water these form free chlorine ions,  which destroy disease-causing pathogens,  reduce odor,  eliminate bacteria and help to remove unwanted elements. The USEPA requires that residual disinfectant is present in finished drinking water to ensure there is disinfectant available throughout the distribution system,  with chlorine acting as one of the disinfectants that provides said residual. However,  the EPA has also set a maximum contaminant level of 4.0 mg\/L for free chlorine due to potential health effects above this level.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI3875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Free Chlorine Medium Range Test Kit - HI3875\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Measurement Type\u003c\/td\u003e\n\u003ctd\u003e Checker Disc\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 3.5 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Number of Tests\u003c\/td\u003e\n\u003ctd\u003e 100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003e DPD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 984 g (34.7 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 235 x 175 x 115 mm (9.2 x 6.9 x 4.5 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI3831F test kit comes with HI93701-0 free chlorine reagent (100 packets), 500 mL deionized water, checker disc, glass vials with caps (2), and 3 mL plastic pipette.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI3875\"\u003eFree Chlorine Medium Range Test Kit - HI3875\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871274926449,"sku":"HI3875","price":7622.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi3875.jpg?v=1792646020"},{"product_id":"ise-slope-check-buffers-with-chloride-background-hi4000-47","title":"ISE Slope Check Buffers with Chloride Background - HI4000-47","description":"\u003cp\u003eHI4000-47 is a package containing pH 4 and pH 7 buffer packets with chloride ions and two plastic beakers. The special pH 4 and pH 7 buffers have a chloride background to verify the inner pH glass assembly housed within the ammonia and carbon dioxide gas sensing ISEs.\u003c\/p\u003e\n\u003cp\u003eBefore assembling an ammonia or carbon dioxide ISE for the first time,  or if reactivating after storage,  the inner glass assembly should be conditioned and tested as a pH electrode. The pH buffer packets can be added to 50 mL of deionized or distilled water and the sensor assembly carefully immersed in solution. When the mV measurement in each buffer solution is stable and recorded,  the mV difference can be calculated. A calculated mV difference equal or greater than 160 mV is acceptable for temperatures between 20 and 25℃.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4000-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e ISE Slope Check Buffers with Chloride Background - HI4000-47\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e packets and beakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 10 packets each buffer; 2 beakers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4000-47\"\u003eISE Slope Check Buffers with Chloride Background - HI4000-47\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871276499313,"sku":"HI4000-47","price":8688.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4000-47.jpg?v=1792646027"},{"product_id":"iodide-combination-ion-selective-electrode-ise-hi4111","title":"Iodide Combination Ion-Selective Electrode (ISE) - HI4111","description":"\u003cp\u003eThe HI4111 iodide selective electrode is a complete potentiometric cell that contains a silver\/silver chloride (Ag\/AgCl) reference housed within a PEI plastic body with a potassium nitrate electrolyte. The internal elements are isolated from the sample by a compressed silver iodide sensing membrane.\u003c\/p\u003e\n\u003cp\u003eHanna's solid state combination ISEs are designed with a cone style junction. The skirted cone geometry of the sensor forms the liquid junction with the test solution at the tip of the junction cone,  producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4111 to measure iodide accurately,  it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the halide ionic strength adjuster (ISA) solution. The halide ISA ensures that the activity coefficient is constant so the concentration of free iodide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4111 iodide solid state ISE can measure from 0.1µM (0.01 mg\/L) to1M (127, 000 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for I\u003csup\u003e-\u003c\/sup\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol width=\"210\"\u003e\n\u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003eMultiply\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003emoles\/L (M) to ppm (mg\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e1.269 x 10\u003csup\u003e5\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cp\u003eppm (mg\/L) to M (moles\/L)\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003cp\u003e7.88 x 10\u003csup\u003e-6\u003c\/sup\u003e\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Combination solid state ISEs are electrodes that detect free ions in a solution. The highly insoluble,  compressed sensing pellet is attached to the electrode by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable PEI Body\u003c\/strong\u003e - The probe body is composed of durable polyetherimide (PEI) plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4111 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA,  the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Iodide Combination Ion-Selective Electrode (ISE) - HI4111\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e combination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e iodide (I\u003csup\u003e-\u003c\/sup\u003e) 1M to 1 10\u003csup\u003e-7\u003c\/sup\u003eM, 127,000 to 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Approximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4111\"\u003eIodide Combination Ion-Selective Electrode (ISE) - HI4111\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278104945,"sku":"HI4111","price":97047.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4111_2016.jpg?v=1792646033"},{"product_id":"bromide-ise-0-1m-standard-hi4002-01","title":"Bromide ISE 0.1M Standard - HI4002-01","description":"\u003cp\u003eHI4002-01 is a 0.1M standard bromide solution used to calibrate the bromide solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Bromide ISE 0.1M Standard - HI4002-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M bromide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4002-01\"\u003eBromide ISE 0.1M Standard - HI4002-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871280955761,"sku":"HI4002-01","price":11531.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4002-01.jpg?v=1792646043"},{"product_id":"ionic-strength-adjuster-isa-for-calcium-ises-hi4004-00","title":"Ionic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00","description":"\u003cp\u003eHI4004-00 is an ionic strength adjuster (ISA) solution for use with calcium ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-00\"\u003eIonic Strength Adjuster (ISA) for Calcium ISEs - HI4004-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281152369,"sku":"HI4004-00","price":12010.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-00.jpg?v=1792646046"},{"product_id":"calcium-ise-0-1m-standard-hi4004-01","title":"Calcium ISE 0.1M Standard - HI4004-01","description":"\u003cp\u003eHI4004-01 is a 0.1M standard calcium solution used to calibrate the calcium liquid membrane ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4004-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCalcium ISE 0.1M Standard - HI4004-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M calcium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4004-01\" target=\"_blank\" rel=\"noopener\"\u003eCalcium ISE 0.1M Standard - HI4004-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281185137,"sku":"HI4004-01","price":11191.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-01.jpg?v=1792646046"},{"product_id":"calcium-ise-conditioning-and-storage-solution-hi4004-45","title":"Calcium ISE Conditioning and Storage Solution - HI4004-45","description":"\u003cp\u003eThe HI4004-45 solution is for the conditioning and storage for the HI4004 and HI4104 calcium liquid membrane ion selective electrodes (ISEs). Measurement of calcium in solutions is determined by calcium ion exchange through the organic polymer membrane. The membrane of the half-cell or combination calcium ISE should be presoaked in HI4004-45 solution for at least one half-hour before calibration to optimize the sensor response. The HI4004-45 is a 500 mL bottle of conditioning and storage solution that ensures optimum measurement performance from the HI4004 and HI4104 calcium ISEs.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4004-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Calcium ISE Conditioning and Storage Solution - HI4004-45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4004-45\"\u003eCalcium ISE Conditioning and Storage Solution - HI4004-45\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871281250673,"sku":"HI4004-45","price":10228.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4004-45.jpg?v=1792646047"},{"product_id":"carbon-dioxide-ise-membrane-kit-3-pcs-hi4005-53","title":"Carbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53","description":"\u003cp\u003eThe HI4005-53 replacement membrane kit contains 3 membrane caps with pre-formed PTFE membranes for the carbon dioxide gas sensing ISE. When the carbon dioxide ISE is first being assembled,  or after a membrane is worn,  the HI4005-53 membrane kit allows for easy assemblage or replacement. By simply screwing on the pre-assembled cap and membrane,  the sensitive PTFE membrane is ensured to remain dry and undamaged for more reliable,  accurate measurements.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4005-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Carbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eincludes 3 membranes\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4005-53\"\u003eCarbon Dioxide ISE Membrane Kit (3 pcs) - HI4005-53\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871283446129,"sku":"HI4005-53","price":15594.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4005-53.jpg?v=1792646051"},{"product_id":"cyanide-half-cell-ion-selective-electrode-ise-hi4009","title":"Cyanide Half-Cell Ion-Selective Electrode (ISE) - HI4009","description":"\u003cp\u003eHanna's solid state half-cell ISEs are designed for use with the HI5315 reference half-cell. The reference half-cell features a cone style junction. The skirted cone geometry of the reference forms the liquid junction with the test solution at the tip of the junction cone, producing a highly stable reference potential and consistent flow rates of electrolyte into the solution. A simple press of the top portion of the ISE makes it easy to empty the electrolyte fill solution and replace when necessary.\u003c\/p\u003e\n\u003cp\u003eFor the HI4009 to measure cyanide accurately, it is important that the ionic strength of the standards and sample be adjusted to a high and constant value with the cyanide ionic strength adjuster (ISA) solution. The alkaline ISA ensures that the activity coefficient is constant so the concentration of free cyanide ions can be measured. Measuring all solutions with a constant ionic strength reduces the margin of error between measurements. The HI4009 cyanide solid state ISE can measure from 1µM (0.026 mg\/L) to 0.01M (260 mg\/L).\u003c\/p\u003e\n\u003cp\u003eConversion Table for CN\u003csup\u003e-\u003c\/sup\u003e\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"220\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e2.602 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e3.843 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eFixed Sensing Modules\u003c\/strong\u003e - Solid state half-cell ISEs are electrodes that detect free ions in a solution. The highly insoluble, compressed sensing pellet is attached to the HI4009 cyanide half-cell by a fixed sensing module for ease of use.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Epoxy Body\u003c\/strong\u003e - The probe body of the cyanide half-cell ISE is composed of durable epoxy resin.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4009 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA solid state sensor electrode develops a voltage due to the ion exchange that occurs between the solution and the inorganic membrane. An equilibrium occurs due to the highly limited solubility of the membrane material in the sample. When the ionic strength of the solution is fixed by the addition of ISA, the voltage is proportional to the concentration of free ions in solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eCyanide Half-Cell Ion-Selective Electrode (ISE) - HI4009\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003esolid state; half-cell\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eCyanide (CN\u003csup\u003e-\u003c\/sup\u003e) 0.01M to 1 10\u003csup\u003e-6\u003c\/sup\u003eM, 260 to 0.026 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eepoxy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; pH 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4009\" target=\"_blank\" rel=\"noopener\"\u003eCyanide Half-Cell Ion-Selective Electrode (ISE) - HI4009\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285412209,"sku":"HI4009","price":98941.5,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4009_2016.jpg?v=1792646060"},{"product_id":"fluoride-ise-0-1m-standard-0-1m-hi4010-01","title":"Fluoride ISE 0.1M Standard 0.1M - HI4010-01","description":"\u003cp\u003eHI4010-01 is a 0.1M standard fluoride solution used to calibrate the fluoride solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4010-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eFluoride ISE 0.1M Standard 0.1M - HI4010-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e0.1M fluoride\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4010-01\" target=\"_blank\" rel=\"noopener\"\u003eFluoride ISE 0.1M Standard 0.1M - HI4010-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871285543281,"sku":"HI4010-01","price":9404.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4010-01.jpg?v=1792646062"},{"product_id":"iodide-ise-0-1m-standard-hi4011-01","title":"Iodide ISE 0.1M Standard - HI4011-01","description":"\u003cp\u003eHI4011-01 is a 0.1M standard iodide solution used to calibrate the iodide solid state ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4011-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Iodide ISE 0.1M Standard - HI4011-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M iodide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4011-01\"\u003eIodide ISE 0.1M Standard - HI4011-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871287607665,"sku":"HI4011-01","price":13086.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4001-40a.jpg?v=1792646068"},{"product_id":"ionic-strength-adjuster-isa-for-potassium-ises-hi4014-00","title":"Ionic Strength Adjuster (ISA) for Potassium ISEs - HI4014-00","description":"\u003cp\u003eHI4014-00 is an ionic strength adjuster (ISA) solution for use with potassium ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4014-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Ionic Strength Adjuster (ISA) for Potassium ISEs - HI4014-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4014-00\"\u003eIonic Strength Adjuster (ISA) for Potassium ISEs - HI4014-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290261873,"sku":"HI4014-00","price":12494.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4014-00.jpg?v=1792646074"},{"product_id":"potassium-ise-0-1m-standard-hi4014-01","title":"Potassium ISE 0.1M Standard - HI4014-01","description":"\u003cp\u003eHI4014-01 is a 0.1M standard potassium solution used to calibrate the potassium liquid membrane ion selective electrode (ISE). Hanna ISE standard solutions are manufactured with high purity chemicals and bottled in our own state-of-the-art facility.\u003c\/p\u003e\n\u003cp\u003eISEs require calibration for accurate readings when performing measurement techniques such as direct measurement and incremental methods. Calibration of up to two points is recommended for enhanced accuracy. Volumetric glassware can be used to make dilutions of standard solutions to bracket the expected concentration of the sample to be measured. ISE calibration standards and sample solutions should always have the same ionic strength; the exact volume of ionic strength adjuster (ISA) must be added to all standards and samples prior to measurement.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4014-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Potassium ISE 0.1M Standard - HI4014-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMoles\/Liter (M) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1M potassium\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4014-01\"\u003ePotassium ISE 0.1M Standard - HI4014-01\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871290327409,"sku":"HI4014-01","price":11191.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4014-01_1200.jpg?v=1792646074"},{"product_id":"sulfide-antioxidant-buffer-saob-for-sulfide-ises-hi4015-00","title":"Sulfide Antioxidant Buffer (SAOB) for Sulfide ISEs - HI4015-00","description":"\u003cp\u003eHI4015-00 is an ionic strength adjuster (ISA) solution for use with silver\/sulfide ion selective electrodes (ISEs). Hanna ISA solutions are formulated to fix the ionic strength of a sample and standards so that they are both constant. Without addition of ISA,  an ion selective electrode would measure ion activity; addition of ISA stabilizes the ionic strength and permits measurements as ion concentration. With some ISEs,  the ISA solution is also used to adjust the solution's pH or to remove any potential interferences from competing ions that are present.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna ISE standard solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eImportance of ISA*\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eFixes a solution's ion activity to be constant so concentration can be determined\u003cstrong\u003e\u003cbr\u003e\u003c\/strong\u003e\n\u003c\/li\u003e\n\u003cli\u003eAdjusts the pH of a solution required for some ISEs\u003c\/li\u003e\n\u003cli\u003eComplexes interfering ions in a sample to allow measurement of free ions of interest\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e* If an ISA solution is used with a sample,  then it must be used with the calibration standards in equal proportions.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI4015-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sulfide Antioxidant Buffer (SAOB) for Sulfide ISEs - HI4015-00\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e No\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1 set\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL; 18 g\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI4015-00\"\u003eSulfide Antioxidant Buffer (SAOB) for Sulfide ISEs - HI4015-00\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871292883313,"sku":"HI4015-00","price":7622.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4015-00.jpg?v=1792646083"},{"product_id":"ph-4-01-technical-calibration-buffer-1-l-hi5004","title":"pH 4.01 Technical Calibration Buffer (1 L) - HI5004-01","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI5004 is a premium quality pH 4.01 technical calibration buffer produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are accurate to ±0.01 pH @ 25℃ and are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/certificateofAnalysis2.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI5004 is Supplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eMean lot value\u003c\/li\u003e\n\u003cli\u003eSRMs that were used\u003c\/li\u003e\n\u003cli\u003eManufacturing date\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eColor coded label for easy pH buffer value identification\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to identify different buffer values\u003c\/li\u003e\n\u003cli\u003eSolution does not contain any dyes that may stain the reference cell of a pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI5004-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH 4.01 Technical Calibration Buffer (500 mL) - HI5004\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e technical calibration buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 4.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 1L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI5004-01\"\u003epH 4.01 Technical Calibration Buffer (500 mL) - HI5004\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871302648177,"sku":"HI5004-01","price":5243.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi5004_1.jpg?v=1792646105"},{"product_id":"ph-7-01-technical-calibration-buffer-1l-hi5007","title":"pH 7.01 Technical Calibration Buffer (1l) - HI5007-01","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI5007-01 is a premium quality pH 7.01 technical calibration buffer produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are accurate to ±0.01 pH @ 25℃ and are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/certificateofAnalysis2.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI5007-01 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eMean lot value\u003c\/li\u003e\n\u003cli\u003eSRMs that were used\u003c\/li\u003e\n\u003cli\u003eManufacturing date\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eColor coded label for easy pH buffer value identification\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to identify different buffer values\u003c\/li\u003e\n\u003cli\u003eSolution does not contain any dyes that may stain the reference cell of a pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI5007-01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI5007 pH 7.01 Technical Calibration Buffer (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e technical calibration buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 7.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 1L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI5007-01\"\u003eHI5007 pH 7.01 Technical Calibration Buffer (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871308775793,"sku":"HI5007-01","price":5243.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi5007_1.jpg?v=1792646114"},{"product_id":"ph-10-01-technical-calibration-buffer-500-ml-hi5010-v","title":"pH 10.01 Technical Calibration Buffer (500 mL) - HI5010-V","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI5010-V is a premium quality pH 10.01 technical calibration buffer made from high purity salts and deionized water for analytical use according to ISO 3696\/BS3978,  using balances checked with certified weight and Class A glassware,  in a temperature controlled environment checked with certified thermometers. Reported values are accurate to ±0.01 pH @ 25℃ and are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/certificateofAnalysis2.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI5010-V is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eMean lot value\u003c\/li\u003e\n\u003cli\u003eSRMs that were used\u003c\/li\u003e\n\u003cli\u003eManufacturing date\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eColor coded label and dyed solution for easy pH buffer value identification\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eEasy to identify different buffer values\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI5010-V\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI5010-V pH 10.01 Technical Calibration Buffer (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e technical calibration buffer, dyed\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 10.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI5010-V\"\u003eHI5010-V pH 10.01 Technical Calibration Buffer (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871308841329,"sku":"HI5010-V","price":3569.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi5010-v.jpg?v=1792646115"},{"product_id":"electrode-storage-solution-120-ml-hi5300-12","title":"Electrode Storage Solution (120 mL) - HI5300-12","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI5300-12 is a solution that can be used to store your pH electrode*. To ensure an optimum response time,  the glass sensor tip and the reference junction of the pH electrode should be kept moist and not be allowed to dry out when not in use. Placing the electrode in a small glass filled with storage solution or replacing the solution in the protective cap is a suitable way to store the electrode. The HI5300-12 should also be used to rehydrate the electrode after a cleaning procedure by soaking for at least one hour before taking measurements.\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screen_Shot_2015-01-23_at_3.44.52_PM.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e* Never store pH or ORP electrodes in distilled or deionized water. Doing so will shorten the life of the sensor.\u003c\/p\u003e\n\u003ch4\u003eAir tight bottle with tamper-proof seal\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eEach bottle marked with lot number and expiration date.\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna storage solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI5300-12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI5300-12 Electrode Storage Solution (120 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e electrode storage solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 120 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI5300-12\"\u003eHI5300-12 Electrode Storage Solution (120 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871313592689,"sku":"HI5300-12","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi5300-12_1.jpg?v=1792646128"},{"product_id":"ph-3-000-millesimal-calibration-buffer-500-ml-hi6003","title":"pH 3.000 Millesimal Calibration Buffer (500 mL) - HI6003","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI6003 is a premium quality pH 3.000 millesimal calibration buffer produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are accurate to ±0.002 pH @ 25℃ and are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/certificateofAnalysis2.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI6003 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eMean lot value\u003c\/li\u003e\n\u003cli\u003eSRMs that were used\u003c\/li\u003e\n\u003cli\u003eManufacturing date\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eColor coded label for easy pH buffer value identification\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to identify different buffer values\u003c\/li\u003e\n\u003cli\u003eSolution does not contain any dyes that may stain the reference cell of a pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003ePackaged in light block bottle\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003ePrevents any oxidation from UV light that could alter the buffer value\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI6003\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI6003 pH 3.000 Millesimal Calibration Buffer (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e millesimal buffer solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.002 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 3.000\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI6003\"\u003eHI6003 pH 3.000 Millesimal Calibration Buffer (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871317557617,"sku":"HI6003","price":4053.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6003.jpg?v=1792646136"},{"product_id":"general-purpose-rinsing-solution-25-x-20ml-sachets-hi70000p","title":"General Purpose Rinsing Solution (25 x 20mL Sachets) - HI70000P","description":"\u003cp\u003eThe most common cause of measurement inaccuracies is an unclean or improperly cleaned electrode or probe. Any residue left on a probe can cross contaminate samples that are being measured or calibration buffers or standards that are used.\u003c\/p\u003e\n\u003cp\u003eRinsing the electrode with the HI70000P rinsing solution will flush away mineral deposits and other coatings.\u003c\/p\u003e\n\u003ch4\u003eConvenience of individual packaging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for field use due to portability\u003c\/li\u003e\n\u003cli\u003eEvery sachet is as fresh as the day it was packaged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEach sachet marked with lot number and expiration date.\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna solutions are specially formulated to have an expiration of 5 years from manufacture for an unopened sachet.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI70000P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI70000P General Purpose Rinsing Solution (25 x 20mL Sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003egeneral purpose rinsing solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003esachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI70000P\" target=\"_blank\" rel=\"noopener\"\u003eHI70000P General Purpose Rinsing Solution (25 x 20mL Sachets)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871326470513,"sku":"HI70000P","price":3569.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70000p.jpg?v=1792646163"},{"product_id":"pool-line-470-mv-orp-test-solution-25-x-20-ml-hi700224p","title":"Pool Line 470 mV ORP Test Solution (25 x 20 mL) - HI700224P","description":"\u003cp\u003eHI700224P is an ORP test solution designed for testing the performance of ORP electrodes. When the ORP electrode is placed in the test solution the reading obtained should be close to the 470 mV value. This solution allows users to quickly see if their electrodes are reading correctly. Using this as a diagnostic tool,  users can then decide if the ORP electrode needs to be cleaned,  polished,  and conditioned or replaced. The test solutions are produced in our state-of-the-art manufacturing facility using reagent grade chemicals in a temperature-controlled environment.\u003c\/p\u003e\n\u003ch4\u003eConvenience of individual packaging\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eIdeal for Service Technicians that perform routine probe maintenance\u003c\/li\u003e\n\u003cli\u003eEach sachet is as fresh as the day it was packaged\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eEach sachet marked with lot number and expiration date\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna ORP test solution is specially formulated to have an expiration of 5 years from the date the solution was packaged.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI700224P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Pool Line 470 mV ORP Test Solution (25 x 20 mL) - HI700224P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e ORP test solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 470 mV ±10 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e sachets\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 25\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 20 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI700224P\"\u003ePool Line 470 mV ORP Test Solution (25 x 20 mL) - HI700224P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871330402673,"sku":"HI700224P","price":3796.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi700224_box.jpg?v=1792646167"},{"product_id":"soil-sample-preparation-solution-500-ml-hi7051l","title":"Soil Sample Preparation Solution (500 mL) - HI7051L","description":"\u003cp\u003eThe HI7051L Soil Sample Preparation Solution is an electrolyte solution used in the measurement of soil pH. The pH of soil is most commonly measured as either a water slurry or electrolyte slurry,  where a set ratio of soil:solvent (solvent is water or electrolyte solution) is chosen; common ratios used for soil pH are 1:1,  1:2 or 1:5,  where more solvent than soil is used when soils-to-be-analyzed contain high amounts of organic matter or clay. Use of an electrolyte solution is usually preferred as it is less affected by soil electrolyte concentration and provides a more consistent measurement for soils whose salt content may fluctuate as a result of seasonal conditions or crop residues. Using the HI7051 solution prior to taking a measurement provides for a more accurate pH reading of soil samples.\u003c\/p\u003e\n\u003ch4\u003eThe HI7051 bottle is labeled with\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eAir tight bottle with tamper-proof seal\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7051L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7051L Soil Sample Preparation Solution (500 mL)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e soil sample preparation solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7051L\"\u003eHI7051L Soil Sample Preparation Solution (500 mL)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871341052273,"sku":"HI7051L","price":1900.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7051l.jpg?v=1792646193"},{"product_id":"groline-ph-7-01-calibration-buffer-with-certificate-of-analysis-230-ml-hi7007-023","title":"GroLine pH 7.01 Calibration Buffer with Certificate of Analysis (230 mL) - HI7007-023 - HI7007-050","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\u003cp\u003eHI7007-023 is a high quality pH 7.01 calibration buffer produced in accordance with ISO 3696\/BS3978 standards using high purity salts,  deionized water,  certified weight-checked balances,  and Class A glassware in a temperature controlled environment monitored with certified thermometers. Reported values are accurate to ±0.02 pH @ 25℃ and are traceable to NIST Standard Reference Materials (SRMs).\u003c\/p\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/certificateofAnalysis2.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eThe HI7007-023 is\u003c\/h4\u003e\n\u003ch4\u003eSupplied with Certificate of Analysis\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eProduct code\u003c\/li\u003e\n\u003cli\u003eLot number\u003c\/li\u003e\n\u003cli\u003eMean lot value\u003c\/li\u003e\n\u003cli\u003eSRMs that were used\u003c\/li\u003e\n\u003cli\u003eManufacturing date\u003c\/li\u003e\n\u003cli\u003eExpiration date\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eColor coded label for easy pH buffer value identification\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eEasy to identify different buffer values\u003c\/li\u003e\n\u003cli\u003eSolution does not contain any dyes that may stain the reference cell of a pH electrode\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7007-050\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e GroLine pH 7.01 Calibration Buffer (230 mL) - HI7007-023\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e Yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Value @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 7.01\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottles\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 500 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7007-050\"\u003eGroLine pH 7.01 Calibration Buffer (230 mL) - HI7007-023\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871344558449,"sku":"HI7007-050","price":1900.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7007-050.jpg?v=1792646204"},{"product_id":"5000-s-cm-conductivity-standard-230-ml-bottle-hi7039m","title":"5000 µS\/cm Conductivity Standard (230 mL Bottle) - HI7039M","description":"\u003cp\u003eH7039M is a premium quality 5, 000 µS\/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696\/BS3978. Additional equipment used in preparation of the solutions include certified weight-checked balances,  Class A glassware and certified thermometers.\u003c\/p\u003e\n\u003ch5\u003eAir tight bottle with tamper-proof seal\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEach bottle marked with lot number and expiration date.\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHanna conductivity standards are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7039M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HI7039M 5000 µS\/cm Conductivity Standard (230 mL Bottle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e conductivity standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Value @25°C\u003c\/td\u003e\n\u003ctd\u003e 5000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7039M\"\u003eHI7039M 5000 µS\/cm Conductivity Standard (230 mL Bottle)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871350227313,"sku":"HI7039M","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7039m_box-certificate_1.jpg?v=1792646219"},{"product_id":"111800-s-cm-conductivity-standard-230-ml-bottle-hi7035m","title":"111800 µS\/cm Conductivity Standard (230 mL Bottle) - HI7035M","description":"\u003cp\u003eH7035M is a premium quality 111, 800 µS\/cm conductivity solution standardized with a conductivity meter that has been calibrated with potassium chloride NIST 2202 SRM (Standard Reference Material) in deionized water for analytical use in accordance with ISO 3696\/BS3978. Additional equipment used in preparation of the solutions include certified weight-checked balances, Class A glassware and certified thermometers.\u003c\/p\u003e\n\u003ch4\u003eAir tight bottle with tamper-proof seal\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eEnsures quality and freshness of solution\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eEach bottle marked with lot number and expiration date.\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna buffers are specially formulated to have an expiration of 5 years from manufacture for an unopened bottle.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI7035M\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI7035M 111800 µS\/cm Conductivity Standard (230 mL Bottle)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003econductivity standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003eno\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003ebottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e230 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Value @25°C\u003c\/td\u003e\n\u003ctd\u003e111800 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI7035M\" target=\"_blank\" rel=\"noopener\"\u003eHI7035M 111800 µS\/cm Conductivity Standard (230 mL Bottle)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871351341425,"sku":"HI7035M","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7035m.jpg?v=1792646220"},{"product_id":"groline-5-000-s-cm-conductivity-standard-with-certificate-230-ml-bottle-hi7039-023","title":"GroLine 5, 000 µS\/cm Conductivity Standard with Certificate (230 mL bottle) – HI7039-023","description":"\u003cp\u003eGroLine 5, 000 uS calibration solution,  box,  certificate of analysis,  230 ml\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI7039-012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e GroLine 5,000 µS\/cm Conductivity Standard with Certificate (120 mL bottle) – HI7039-012\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Conductivity standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e Bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 120 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Value @25°C\u003c\/td\u003e\n\u003ctd\u003e 5,000 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI7039-012\"\u003eGroLine 5,000 µS\/cm Conductivity Standard with Certificate (120 mL bottle) – HI7039-012\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871355601265,"sku":"HI7039-023","price":1674.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi7039-023_box-certificate-720x720-3c972a0b-3ddd-4c0d-8706-5c65eb9bef68.png?v=1792646233"},{"product_id":"sodium-hydroxide-0-1n-1l-hi70456","title":"Sodium Hydroxide 0.1N,  1L - HI70456","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI70456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Sodium Hydroxide 0.1N, 1L - HI70456\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003e Sodium Hydroxide\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCertificate of Analysis\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNormal (N) @ 25°C\u003c\/td\u003e\n\u003ctd\u003e 0.1 N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePackage\u003c\/td\u003e\n\u003ctd\u003e bottle\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eQuantity\u003c\/td\u003e\n\u003ctd\u003e 1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSize\u003c\/td\u003e\n\u003ctd\u003e 1 L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI70456\"\u003eSodium Hydroxide 0.1N, 1L - HI70456\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871359861105,"sku":"HI70456","price":2240.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi70456-1200by1200-rgb.jpg?v=1792646241"}],"url":"https:\/\/hannainst.in\/collections\/stock-clearance.oembed?page=4","provider":"hanna","version":"1.0","type":"link"}