Hanna Instruments Worldwide
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +1 (800) 426-6287

HI6522-02 pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit

SKU: HI6522-02 N/A
Request for a quote

GST and Shipping charges are extra

Set yourself up for testing success with our pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit (HI6522). Our high-performing benchtop meter is ready-to-use straight out of the box and is fully equipped with everything you need to test. Includes necessary modules, electrodes, solutions, and more.

  • Precise and consistent. Achieve quick, accurate, and repeatable results
  • Reliable and efficient. Ensure quality and meet requirements with easy digital record keeping and increased traceability
  • Simple and straightforward. Intuitive navigation menus, built-in help guides, and video tutorials make testing hassle-free

Fits seamlessly into any laboratory or industry environment.

Perfect for chemists, researchers, educators, food manufacturers, beverage producers, and metal finishers to name a few.

QTY:

  Add to wish list

HI6522-02 pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit

 

HI6522-02 (EU power plug) is supplied with HI6000 housing unit; HI6000-2 pH/ORP/ISE hardware module (installed); HI6000-3 EC hardware module (installed); HI1131B pH electrode; HI7662-TW temperature probe; HI7631233 EC & resistivity probe; pH 4.01 buffer solution, 2 sachets; pH 7.01 buffer solution, 4 sachets; pH 10.01 buffer solution, 2 sachets; electrode cleaning solution, 2 sachets; pH & ORP electrode storage solution (25 mL); 3.5M KCl electrolyte solution (30 mL); capillary pipette, 1 piece; 1413 μS/cm standard solution, 4 sachets; 5000 μS/cm standard solution, 2 sachets; 12880 μS/cm standard solution, 2 sachets; electrode rinse solution, 2 sachets; electrode holder with base plate, screw, cable holder clip (requires mounting); 24 VDC power adapter; USB-C to USB-A cable; meter quick reference guide; hardware modules quick reference guides and quality certificates; probes and meter quality certificate.

Specification NameDetail
SkuHI6522-02
pH Range-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH
pH Resolution0.1 pH; 0.01 pH; 0.001 pH
pH Accuracy±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)
Calibration PointsUp to 5
Calibration TypeAutomatic; Semiautomatic; Manual
Standard BuffersHanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)
Custom BuffersUp to 5
Custom GroupOption to select from eight standard buffers and user-defined custom buffers
First Calibration PointOffset or Point (user setting)
Isopotential Point-2.000 to 20.000 pH
mV Range-2000.0 to 2000.0 mV
mV Resolution1 mV; 0.1 mV
mV Accuracy±0.2 mV ±1 last significant digit
mV CalibrationSingle point offset, ±2000.0 mV
ISE Range1.0×10¯5 to 300.0 ppt (g/L or mg/mL)
5.0×10¯3 to 1.0×105 ppm (mg/L or µg/mL)
1.0 to 5.0×107 ppb (µg/L)
1.0×10¯7 to 10.0 M (mol/L)
1.0×10¯4 to 1.0×104 mmol/L
1.0×10¯6 to 60.0 %w/v
5.0×10¯7 to 5.0×107 user
ISE Resolution1, 2, 3 significant digits
ISE Accuracy±0.5% (monovalent ions); ±1% (divalent ions)
ISE Calibration PointsUp to 5
ISE Calibration TypeAll Standards; Standard Group
ISE Standards7 standard solutions available for each concentration unit
ISE Custom StandardsUp to 5
ISE Custom GroupUp to 5
Conductivity Range0.000 to 9.999 μS/cm; 10.00 to 99.99 μS/cm; 100.0 to 999.9 μS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm
Conductivity Resolution0.001 μS/cm; 0.01 μS/cm; 0.1 μS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm
Conductivity Accuracy±1 % of reading or ±0.010 μS/cm, whichever is greater
Conductivity Cell Constant0.0500 to 200.0000 /cm
Conductivity Calibration TypeAutomatic; Manual
Conductivity Calibration PointsSingle; Up to 5
Conductivity Calibration Solutions84 μS/cm; 1413 μS/cm; 5000 μS/cm; 12880 μS/cm; 80000 μS/cm; 111800 μS/cm
Resistivity Range1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm
Resistivity Resolution0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm
Resistivity Accuracy±1 % of reading or ±1 Ω•cm, whichever is greater
Total Dissolved Solids (TDS) Range0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)
Total Dissolved Solids (TDS) Resolution0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt
Total Dissolved Solids (TDS) Accuracy±1 % of reading or ±0.01 ppm, whichever is greater
Salinity Range0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale)
Salinity Resolution0.01 PSU; 0.01 ppt; 0.1 %
Salinity Accuracy±1 % of reading
Salinity Calibration1 point, using 100 % salinity calibration solution (% scale only)
Temperature Range−20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K
Temperature Resolution0.1 °C; 0.1 °F; 0.1 K
Temperature Accuracy±0.2 °C; ±0.4 °F; ±0.2 K
Temperature CalibrationSingle point, adjustable
Temperature CompensationFor pH: Automatic; Manual
For Conductivity: Linear; Natural; Standard; Disabled
Reference TemperatureFor Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)
Temperature CoefficientFor Conductivity: 0.00 to 10.00 %/°C
Reading ModeDirect
Direct/Autohold
ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction
Conductivity Only: Direct/USP
Basic ViewMeasurement data; Measurement profile (if enabled); Stability status
Simple GLP ViewBasic view information
For pH: pH Last calibration date, slope, offset (pH, Rel. MV – ISE Only)
For Conductivity: Last calibration date and offset
Full GLP ViewSimple GLP Information; Calibration point details (pH, ISE, Conductivity, and Salinity)
Graph ViewBasic view information; measurement versus time graph
Table ViewBasic view information; Table with measurements updated every second
Reading Stability CriteriaAccurate; Medium; Fast
Reading Sampling Rate1000 ms
Logging TypeAutomatic; Manual; Autohold
Logging Number of Records50,000 maximum per file and stores at least 1,000,000 data points per user
Logging Automatic Interval1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes
Logging Sample IDIncremental Mode; Manual
Logging Export Option.CSV file format
Connectivity USB-A2 ports
keyboard and/or printer input
USB Flash Drive
Connectivity USB-C1 port
PC Connectivity and USB-C Type Flash Drive
Connectivity Wi-Fi & EthernetFTP; Web Server (Log transfer and download); Email
Connectivity RS232Connecting peripherals
Calibration ReminderDaily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled
UsersUp to 9 users and the default administrator account
Power SupplyDC adapter 100-240 VAC to 24 VDC 2A
Environment0 to 50 °C / 32 to 122 °F / 273 to 323 K maximum 95 % RH non-condensing
Dimensions205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)
Weight8.05 lbs

Reviews

There are no reviews yet.

Be the first to review “HI6522-02 pH/ORP/ISE and EC/TDS Benchtop Meter Starter Kit”

Your email address will not be published. Required fields are marked *