{"product_id":"advanced-conductivity-benchtop-meter-hi6321","title":"Advanced Conductivity Benchtop Meter - HI6321-02","description":"\u003cp\u003eHI6321 is a streamlined Conductivity\/Resistivity\/TDS\/Salinity\/Temperature benchtop meter with a large touch screen display, comprised of a housing and an integrated conductivity measurement module.\u003c\/p\u003e\n\u003cp\u003eCompact and easy to operate, the HI6321 includes Hanna’s HI7631233 four-ring conductivity\/ resistivity\/TDS\/salinity probe.\u003c\/p\u003e\n\u003cp\u003eRecommended for a wide range of industrial process water applications, HI7631233 provides stable measurements over a wide measurement range and does not require frequent calibrations. An integral temperature sensor measures the process temperature and adjusts the measured conductivity to a reference temperature by applying specialized compensation algorithms:\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLinear: appropriate when it is assumed that the temperature coefficient of variation has the same value for all measurement temperatures.\u003c\/li\u003e\n\u003cli\u003eStandard: appropriate for high-purity water measurements and documented in ASTM Standard D5391-14. This setting should be used for \u0026gt;1Mohm.cm resistivity measurements.\u003c\/li\u003e\n\u003cli\u003eNatural: appropriate for natural ground, well, or surface water (or water with similar composition) in accordance with ISO7888 standard.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eThe result is reliable electrolytic conductivity (EC), TDS (Total Dissolved Solids), resistivity, or Seawater Salinity in percent, psu, or ppt units.\u003c\/p\u003e\n\u003cp\u003eTDS is a calculated value based on the conductivity of the solution (TDS = factor x EC25). A TDS factor is a conversion factor used to change an EC measurement to a ppm measurement.\u003c\/p\u003e\n\u003cp\u003eSal psu: The practical salinity of seawater relates the ratio of electrical conductivity of a normal seawater sample at 15 ℃ and 1 atmosphere to a potassium chloride solution (KCl) with a mass of 32.4356 g\/Kg water at the same temperature and pressure. Under these conditions the ratio is equal to 1 and S=35. The practical salinity scale may be applied to values 0 through 42.00 psu at temperatures between 0 to 35 ℃.\u003c\/p\u003e\n\u003cp\u003eSal ppt: measurements expressed in ppt are based on the Natural Seawater Scale that extends from 0.00 to 80.00 g\/L and covers 10 to 31 ℃ temperature range. It determines the salinity based upon a conductivity ratio of sample to standard seawater at 15 ℃ and an approximate salinity value of 35 in seawater.\u003c\/p\u003e\n\u003cp\u003eSal %: in this scale 100% salinity is equivalent to roughly 10% solids.\u003c\/p\u003e\n\u003ch2\u003eUser interface\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003e7-inch capacitive touch screen with multi-touch support\u003c\/li\u003e\n\u003cli\u003eCapacitive touch back, home and system menu keys\u003c\/li\u003e\n\u003cli\u003eUser-friendly icons and symbols allow users to easily navigate and interpret the instrument functions.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eThe user can select between five different views:\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eBasic measurement configuration\u003c\/li\u003e\n\u003cli\u003eSimple GLP with calibration information\u003c\/li\u003e\n\u003cli\u003eFull GLP with electrode status and calibration point details\u003c\/li\u003e\n\u003cli\u003eLive updated, interactive graph\u003c\/li\u003e\n\u003cli\u003eTabulated data with date, time, and notes\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eMeasurement\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure µS\/cm, mS\/cm (Conductivity); ω·cm, kω·cm, Mω·cm (Resistivity); ppm, ppt (TDS); ppt, PSU,\n% (Salinity) with temperature\u003c\/li\u003e\n\u003cli\u003eApplication-specific profiles allow quick and direct measurement without the need to update the sensor\nand system settings\u003c\/li\u003e\n\u003cli\u003eActive log during measurement o Measurement stability indicator (using the Stability Criteria setting)\u003c\/li\u003e\n\u003cli\u003eReading modes: direct and direct\/autohold\u003c\/li\u003e\n\u003cli\u003eTemperature compensation can be Automatic or set manually\u003c\/li\u003e\n\u003cli\u003eAudible and\/or alarm messages for measurements outside of predefined limits\u003c\/li\u003e\n\u003cli\u003eGalvanic isolation for conductivity measurement\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCalibration\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eStandard single point salinity calibration in 100% salinity standard, with the reading salinity scale set to %\u003c\/li\u003e\n\u003cli\u003eStandard single or multiple conductivity calibration with standards\u003c\/li\u003e\n\u003cli\u003eNon-volatile memory saves data and settings\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eLogging\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eData log collection of at least 1, 000, 000 data points (with time and date stamp)\u003c\/li\u003e\n\u003cli\u003eLogging types: manual, automatic, autohold\u003c\/li\u003e\n\u003cli\u003eSample ID for manual and Autohold data\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eConnectivity features \u0026amp; services\u003c\/h2\u003e\n\u003cul\u003e\n\u003cli\u003eTransfer logged data to a USB thumb drive\u003c\/li\u003e\n\u003cli\u003eLog files that include measurements and calibration data (as .csv file)\u003c\/li\u003e\n\u003cli\u003eFTP and email for log export via Ethernet and Wi-Fi connection o USB type A for USB stick,\nkeyboard, and printer\u003c\/li\u003e\n\u003cli\u003eUSB type C for USB stick and PC connection\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 µS\/cm; 10.00 to 99.99 µS\/cm; 100.0 to 999.9 µS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 µS\/cm; 0.01 µS\/cm; 0.1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 µS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±1 Ω·cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading (±0.01 ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 for Practical Scale \/ Natural Sea Water 0.1 % for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C; ±0.4 °F; ±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration points\u003c\/td\u003e\n\u003ctd\u003eAuto standard recognition \/ User standard, Single Point \/ Multi Point calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Standard solutions\u003c\/td\u003e\n\u003ctd\u003e84.00 µS\/cm, 1.413 mS\/cm, 5.000 mS\/cm, 12.88 mS\/cm, 80.00 mS\/cm, 111.8 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConductivity Calibration Reminder\u003c\/td\u003e\n\u003ctd\u003eDisabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003e1 point for Percent Scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Modes\u003c\/td\u003e\n\u003ctd\u003eDirect Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Stability criteria\u003c\/td\u003e\n\u003ctd\u003eAccurate Medium Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading Sampling\u003c\/td\u003e\n\u003ctd\u003erate 1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information Last calibration date, oﬀset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information and calibration point details\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Table\u003c\/td\u003e\n\u003ctd\u003eMeasurements updated every second are displayed in table\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Views Graph (Plot)\u003c\/td\u003e\n\u003ctd\u003eMeasurement versus time graph can be panned or zoomed (pinch-to-zoom technology)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eAutomatic, Manual, Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Number of records\u003c\/td\u003e\n\u003ctd\u003e50 000 maximum per ﬁle Stores at least 1 000 000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Automatic interval\u003c\/td\u003e\n\u003ctd\u003e1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Sample ID\u003c\/td\u003e\n\u003ctd\u003eIncremental mode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Export option\u003c\/td\u003e\n\u003ctd\u003e.csv ﬁle format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eUsers\u003c\/td\u003e\n\u003ctd\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-A\u003c\/td\u003e\n\u003ctd\u003e2 ports for keyboard input or USB thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity USB-C\u003c\/td\u003e\n\u003ctd\u003e1 port for PC connectivity and USB-C type thumb drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/td\u003e\n\u003ctd\u003eFTP Web server Log transfer and download Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity RS232\u003c\/td\u003e\n\u003ctd\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003eDC adapter 100-240AC to 24VDC 2.5A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 - 50 °C \/ 32 - 122 °F \/ 273 - 323 K maximum 95% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.2 kg (26.5 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI6321\" target=\"_blank\" rel=\"noopener\"\u003eAdvanced Conductivity Benchtop Meter - HI6321\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871322734961,"sku":"HI6321-02","price":148128.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi6321-right-facing-700x700-d4924805-c4b9-4224-b973-d8a72a57f915.jpg?v=1792646150","url":"https:\/\/hannainst.in\/products\/advanced-conductivity-benchtop-meter-hi6321","provider":"hanna","version":"1.0","type":"link"}