{"product_id":"ammonia-combination-ion-selective-electrode-ise-hi4101","title":"Ammonia Combination Ion-Selective Electrode (ISE) - HI4101","description":"\u003cp\u003eAmmonia can exist in two different forms: ammonia as a gas (NH\u003csub\u003e3\u003c\/sub\u003e) and ammonium as the ionized form (NH\u003csup\u003e4+\u003c\/sup\u003e). The concentration of each form in a solution is dependent on the solution's pH. The pKa is the pH value at which ammonia and ammonium are in equilibrium. The pKa of the ammonia\/ammonium relationship is 9.24; thus, at a pH of 9.24 there will be an equal concentration of ammonia and ammonium. As pH decreases, becoming more acidic, the concentration of ammonium increases and ammonia decreases. The opposite occurs as the pH increases. The actual concentration for either species can be determined by knowing the concentration of ammonia and the pH of the sample.\u003c\/p\u003e\n\u003cp\u003eFor the HI4101 to measure ammonia accurately, it is important that the pH of the calibration standards and sample be raised with the ammonia ionic strength adjuster (ISA) solution. The ammonia ISA raises the pH of the solution to pH 11. Any ammonium present in the calibration standards and sample will be converted to ammonia, ensuring an accurate measurement. The HI4101 ammonia gas sensing ISE can measure from 1µM (0.02 mg\/L) to 1M (17, 000 mg\/L).\u003c\/p\u003e\n\u003ch4\u003eConversion Table for NH\u003csub\u003e3\u003c\/sub\u003e\n\u003c\/h4\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"200\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emoles\/L (M) to ppm (mg\/L)\u003c\/td\u003e\n\u003ctd\u003e1.70 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eppm (mg\/L) to M (moles\/L)\u003c\/td\u003e\n\u003ctd\u003e5.882 x 10\u003csup\u003e-5\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cp\u003eConversion Table for NH\u003csub\u003e3\u003c\/sub\u003e-N\u003c\/p\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ccolgroup\u003e \u003ccol width=\"*\"\u003e \u003ccol width=\"*\"\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003c\/td\u003e\n\u003ctd\u003eMultiply\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolarity (moles\/L) NH\u003csub\u003e3\u003c\/sub\u003e to mg\/L (ppm) NH\u003csub\u003e3\u003c\/sub\u003e-N\u003c\/td\u003e\n\u003ctd\u003e1.40 x 10\u003csup\u003e4\u003c\/sup\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003ch2\u003eFeatures at-a-glance\u003c\/h2\u003e\n\u003cp\u003e\u003cstrong\u003eReplaceable PTFE Membranes\u003c\/strong\u003e - Gas sensing ISEs are combination electrodes that detect dissolved gases in a solution. The sensing element is separated from the sample solution by a gas permeable, PTFE membrane that is easy to replace.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDurable Delrin® Body\u003c\/strong\u003e - The probe body is composed of durable Delrin plastic.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBNC Connection\u003c\/strong\u003e - The HI4101 has a universal BNC connector for easy connection to any benchtop meter with a female BNC probe input.\u003c\/p\u003e\n\u003ch2\u003eTheory of Operation\u003c\/h2\u003e\n\u003cp\u003eA gas sensor works due to the partial pressure of the measured gas in solution. The dissolved gas in the sample diffuses into the membrane and changes the pH in a thin film of unbuffered electrolyte on the surface of the internal pH sensor. Diffusion continues until the partial pressure of the sample and the thin film of electrolyte are the same. The pH change is proportional to the concentration of dissolved gas in the sample solution.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI4101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eAmmonia Combination Ion-Selective Electrode (ISE) - HI4101\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDescription\u003c\/td\u003e\n\u003ctd\u003ecombination\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003eammonia (NH₃) 1.0M to 1 x 10-6 M, 17000 to 0.02 mg\/L (ppm); ammonia-nitrogen (NH₃-N) 14000 to 0.016 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e0 to 40 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003eDelrin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptimum pH Range\u003c\/td\u003e\n\u003ctd\u003e\u0026gt; pH 11\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e120 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003ecoaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003eBNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003eApproximate Slope -56 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI4101\" target=\"_blank\" rel=\"noopener\"\u003eAmmonia Combination Ion-Selective Electrode (ISE) - HI4101\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871278367089,"sku":"HI4101","price":104361.75,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi4101_y2016.jpg?v=1792646035","url":"https:\/\/hannainst.in\/products\/ammonia-combination-ion-selective-electrode-ise-hi4101","provider":"hanna","version":"1.0","type":"link"}