{"product_id":"conductivity-analog-controller-with-direct-input-from-potentiometric-probe-0-00-to-19-99-ms-cm-hi943500","title":"Conductivity Analog Controller with Direct Input from Potentiometric Probe, 0.00 to 19.99 mS\/cm - HI943500 - HI943500B","description":"\u003cp\u003eThese controllers allow direct connection of a potentiometric conductivity probe (HI7638) with a cable up to 20 m long,  without needing a transmitter to amplify the signal.\u003c\/p\u003e\n\u003cp\u003eThe instruments are designed with a standard DIN panel mount withmembrane keypads and large LCD on the front,  and provide a seriesof auto-diagnostic functions.\u003c\/p\u003e\n\u003cp\u003eProbes,  power supply,  contacts and recorders are connected on therear panel through screw terminals.\u003c\/p\u003e\n\u003cp\u003eFour models with different measurement ranges are available to suit any application needs\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eHI 943500A  from 0.0 to 199.9 mS\/cm\u003c\/li\u003e\n\u003cli\u003eHI 943500B  from 0.00 to 19.99 mS\/cm\u003c\/li\u003e\n\u003cli\u003eHI 943500C  from 0 to 1999 μS\/cm\u003c\/li\u003e\n\u003cli\u003eHI 943500D  from 0.0 to 199.9 μS\/cm\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eHI943500 Series Conductivity Controller's FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch4\u003eNo Need for a Transmitter\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThese controllers allow the direct connection of a potentiometric conductivity probe (HI 7638) with a cable up to 20 meters long,  without using any transmitter\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eSelf-testing Diagnostics\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eDesigned with built-in diagnostic functions to enable the user to check and troubleshoot the instrument. The checks performed are through the front panel keys and can be used to isolate the cause of malfunction.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eVisual Indicator\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe LED on the front panel indicates the operating status of the controller.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eAutomatic Temperature Compensation\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe automatic temperature compensation (ATC) is performed directly by the HI 7638 probe with built-in temperature sensor.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eQuality Construction\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe controllers are housed in sturdy aluminum casings with ABS plastic front panels. The mounting brackets that are supplied with the meter,  can be installed securely and quickly. When in operation,  and with the transparent protective cover installed,  the units comply with IP42 standards (see chart in section 20 for IP codes). The use of this design protects the unit from the conditions associated with industrial environments,  ensuring a long and trouble-free operation.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eRecorder Output\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe ability to record data from the process you are monitoring greatly enhances process troubleshooting. By simply connecting a recorder to the controller's output terminals (choose between 0 to 20 mA or 4 to 20 mA according to your needs),  users are able to acquire a hard copy for demonstrative or analytical purposes.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eFriendly Interface\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe instruments are designed with a standard DIN panel mount with membrane keypads on the front,  a large LCD and with auto-diagnostic functions\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI943500C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity Analog Controller with Direct Input from Potentiometric Probe - HI943500-0 to 1999 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e HI943500A: 0.0 to 199.9 mS\/cm,    HI943500B: 0.00 to 19.99 mS\/cm,   HI943500C: 0 to 1999 µS\/cm,    HI943500D: 0.0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e HI943500A: 0.1 mS\/cm,   HI943500B: 0.01 mS\/cm,   HI943500C: 1 µS\/cm,   HI943500D: 0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% F.S\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, two point, through offset and slope trimmers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic, 0 to 60°C (32 to 140°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e  4-20 mA (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e flame retardant ABS body and front panel; transparent splash-proof front cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Cutout\u003c\/td\u003e\n\u003ctd\u003e  141 x 69 mm (5.6 x 2.7”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e 115 or 230 VAC ±10% (user selectable); 50\/60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e -10 to 50°C (14 to 122°F); RH max 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1 kg (2.2 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eThe HI943500 series is supplied complete with mounting brackets and instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI943500C\"\u003eConductivity Analog Controller with Direct Input from Potentiometric Probe - HI943500-0 to 1999 µS\/cm\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871433949553,"sku":"HI943500B","price":71317.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/hannainst.in\/products\/conductivity-analog-controller-with-direct-input-from-potentiometric-probe-0-00-to-19-99-ms-cm-hi943500","provider":"hanna","version":"1.0","type":"link"}