{"product_id":"conductivity-ec-controller-0-0-199-9-s-cm-bl983320-1-115-230vac","title":"Conductivity (EC) Controller (0.0 - 199.9 µS\/cm) - BL983320-1 | 115\/230VAC","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983320_angle.jpg\" alt=\"BL983320\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983320 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off),  placed in control (Auto),  or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983320_rear.jpg\" alt=\"BL983320\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power,  conductivity probe and relay that can be used to operate a dosing pump,  valve,  audible alarm,  or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983320 mini controller uses the \u003cstrong\u003e\u003ca href=\"https:\/\/www.hannainst.com\/ec-tds-probe-for-low-range-mini-controllers.html\" target=\"_blank\" rel=\"noopener\"\u003eHI7634\u003c\/a\u003e\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL983320-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Conductivity (EC) Controller (0.0 - 199.9 µS\/cm) - BL983320-1 | 115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e 0.0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e 0.1 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e automatic from 5 to 50°C (41 to 122°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Correction Coefficient\u003c\/td\u003e\n\u003ctd\u003e β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e contact closed when measure \u0026gt; setpoint \u003cbr\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from 0 to 199.9 µS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 12 VDC adapter (included)\u003cbr\u003e models “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e models “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL983320-1 (115\/230 VAC) and BL983320-0 (12 VDC) supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL983320-1\"\u003eConductivity (EC) Controller (0.0 - 199.9 µS\/cm) - BL983320-1 | 115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871168561521,"sku":"BL983320-1","price":22547.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/hannainst.in\/products\/conductivity-ec-controller-0-0-199-9-s-cm-bl983320-1-115-230vac","provider":"hanna","version":"1.0","type":"link"}