{"product_id":"digital-galvanic-dissolved-oxygen-probe-for-hi98199-hi764103","title":"Digital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/digital_electrode_thm.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Microchip\u003c\/h4\u003e\n\u003cp\u003eThe built-in microchip stores sensor type,  serial number and calibration information including date,  time,  and calibration points. This information is automatically retrieved by HI98199 once the probe is plugged in. The ability to transfer information allows for hot swapping of probes without recalibrating. All DO measurements are performed within the probe and transferred digitally to the meter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Galvanic_DO_Cap.png\" alt=\" Galvanic Technology \" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGalvanic Technology\u003c\/h4\u003e\n\u003cp\u003eThe galvanic technology is a passive from of measurement is that the probe generates a voltage spontaneously based on the dissolved oxygen concentration that passes through the membrane and reacts with the fill solution. There is no warm up time with galvanic probes since the reaction is taken place continuously.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ScrewCaps.png\" alt=\"Replaceable Membranes\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReplaceable Membranes\u003c\/h4\u003e\n\u003cp\u003eWith screw-on caps,  the DO HDPE membrane is easy to replace for faster maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/DO_ATC.png\" alt=\"Replaceable DO membrane caps\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eDO measurements are automatically compensated for temperature changes\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/9819x-quickconnect.png\" alt=\"Replaceable DO membrane caps\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eQuick Connect Din Connector\u003c\/h4\u003e\n\u003cp\u003eWith screw-on caps,  the DO HDPE membrane is easy to replace for faster maintenance.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI764103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Digital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e ABS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e built-in\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 4 meter (13.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e quick connect DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e wastewater, water, aquaculture, beverage\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e to only be used with HI98199\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI764103\"\u003eDigital Galvanic Dissolved Oxygen Probe for HI98199 – HI764103\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871407243633,"sku":"HI764103","price":39804.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi764103_front.jpg?v=1792646467","url":"https:\/\/hannainst.in\/products\/digital-galvanic-dissolved-oxygen-probe-for-hi98199-hi764103","provider":"hanna","version":"1.0","type":"link"}