{"product_id":"digital-gel-filled-pei-body-orp-electrode-for-field-applications-hi36200","title":"Digital Gel Filled PEI Body ORP Electrode for Field Applications – HI36200","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHanna Instruments offers a wide variety of ORP electrodes that are designed for many different applications. The type of material used for the sensing pin,  type of glass or plastic used for the body material,  type of junction,  type of reference and electrolyte used are just some of the design considerations.\u003c\/p\u003e\n\u003cp\u003eThe HI36200 features a platinum sensing pin,  PEI body,  and a single ceramic junction.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/digital_electrode_thm.png\" alt=\"Microchip\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-in Microchip\u003c\/h4\u003e\n\u003cp\u003eThe built-in microchip stores sensor type,  serial number and calibration information including date,  time,  offset,  slope,  probe condition and buffers used. This information is automatically retrieved by edge® once the electrode is plugged in. The ability to transfer information allows for hot swapping of probes without having to recalibrate. All pH measurements are performed within the electrode and transferred digitally to the meter. This overcomes any noise issues associated with the traditional high impedance analog measuring system. Electrical noise can be generated from a built in temperature sensor and while working in a humid environment.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI3230_platinum.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003ePlatinum Sensing Pin\u003c\/h4\u003e\n\u003cp\u003eThe HI36200 ORP sensor is made with platinum. An ORP sensor must be chemically inert; it cannot be oxidized or reduced itself. It must also have the proper surface characteristics to promote rapid electron exchange,  a property known as high exchange current density. Two noble metals have proven to work well for this purpose: pure platinum and pure gold are both used in the construction of ORP sensors. The platinum sensor is often preferred because it is mechanically simpler and safer to produce. Platinum can be welded to glass and has the same thermal coefficient. The platinum sensor signal is carried through the electrode body,  and together with the reference signal is conducted to the measurement meter.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI3230_pei.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003ePEI Body\u003c\/h4\u003e\n\u003cp\u003eThe body of the HI36200 is composed of polyetherimide (PEI) resin. The PEI body is suitable for a wide range of applications and excels in field measurements due to its durability. The shielding around the spherical glass tip minimizes breakage due to accidental bumping or dropping of the electrode. The PEI plastic is a high quality plastic that is chemically resistant to many aggressive chemicals.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI3230_junction.png\" alt=\"digital electrode\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSingle Ceramic Junction\u003c\/h4\u003e\n\u003cp\u003eThe outer junction of an electrode,  also known as a salt bridge,  is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. Other junction types are available with higher flow rates and made with different materials.\u003c\/p\u003e\n\u003ch5\u003eBuilt-In Temperature Sensor\u003c\/h5\u003e\n\u003cp\u003eHI36200 features a built-in thermistor temperature sensor. A thermistor temperature sensor provides for a high accuracy temperature reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI36200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Digital Gel Filled PEI Body ORP Electrode for Field Applications – HI36200\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e ORP: ±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e single, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e ceramic, single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e PEI\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e platinum pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 2 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e -5 to 70°C (23 to 158°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 163.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e 3.5 mm connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e field applications\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI36200\"\u003eDigital Gel Filled PEI Body ORP Electrode for Field Applications – HI36200\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871251497329,"sku":"HI36200","price":23067.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi36200.jpg?v=1792645946","url":"https:\/\/hannainst.in\/products\/digital-gel-filled-pei-body-orp-electrode-for-field-applications-hi36200","provider":"hanna","version":"1.0","type":"link"}