{"product_id":"dissolved-oxygen-controller-with-extended-range-and-analog-output-hi8410","title":"Dissolved Oxygen Controller with Extended Range and Analog Output - HI8410","description":"\u003cp\u003eHI 8410 is a panel-mounted DO controller designed for simplicity of use in a wide range of industrial process applications. Dissolved Oxygen is indicated in mg\/L (ppm) or in % of saturation in accordance with the selection switch on the back panel. The temperature can be measured in the range from -5 to 50 ℃. The Dissolved Oxygen readings are automatically compensated for the temperature effects on the oxygen solubility and membrane permeability. Moreover, the salinity compensation feature allows the determination of Dissolved Oxygen even in salty waters.\u003c\/p\u003e\n\u003cp\u003eThe instruments are designed with a standard DIN panel mount with membrane keypads and large LCD with backlight on the front, and provide a series of auto-diagnostic functions. Probes, power supply, contacts and recorders are connected on the rear panel through screw terminals.\u003c\/p\u003e\n\u003cp\u003eThe DO probe is provided with a membrane covering the galvanic sensor and a built-in thermistor for temperature measurement and compensation.\u003cbr\u003e\nThe Oxygen that passes through the membrane causes an electric current flow, from which the oxygen concentration is determined. Other features include: recorder output in 0-20 mA or 4-20 mA configuration; LED indicators which identify whether the controller is in operation mode or setup selection mode; overtime control function; hysteresis setting. The instrument is supplied with a plastic front cover and two mounting brackets. Power cables are not included.\u003c\/p\u003e\n\u003ch4\u003eHI8410 FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch4\u003eFail Safe Alarm System\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eHanna's exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eAutomatic Temperature Compensation\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe Dissolved Oxygen readings are automatically compensated for the temperature effects on the oxygen solubility and membrane permeability\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eSalinty Compensation\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe salinity compensation feature allows the determination of Dissolved Oxygen even in salty waters.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eSimple to Use\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe instruments are designed with a standard DIN panel mount with membrane keypads and large LCD with backlight on the front, and provide a series of auto-diagnostic functions.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eAnalog Output\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eTo enhance troubleshooting and the ability to record data while monitoring, simply attach a recording device to the instrument's 4 to 20 mA output contacts, conveniently located on the front panel, to obtain a copy of the results on demand.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch4\u003eDiagnostic Tests\u003c\/h4\u003e\n\u003cul\u003e\u003cli\u003eThe HI 8410 controllers are designed with built-in diagnostic functions to enable the user to check and troubleshoot the instrument. The checks performed are through the front panel keys and can be used to isolate the cause of malfunction.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI8410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eDissolved Oxygen Controller with Extended Range and Analog Output - HI8410\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Type\u003c\/td\u003e\n\u003ctd\u003egalvanic: HI76410\/4 with 4 m (13.1’) cable or HI76410\/10 with 10 m (32.8’) cable (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 mg\/L (ppm) O₂; 0 to 600 % O\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L (ppm) or 1% (O₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (O₂)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eManual, one point, in saturated air\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic, from -5 to 50 °C (23 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Compensation\u003c\/td\u003e\n\u003ctd\u003e0 to 51 g\/L (resolution 1 g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e1, isolated, 2A, max. 240V, resistive load, 1,000,000 strokes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e5 to 600 % O2 0.5 to 50.0 mg\/L (ppm) O2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Hysteresis Band\u003c\/td\u003e\n\u003ctd\u003e0.5 to 2.4 mg\/L (ppm) O2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003eOFF\/AUTO\/ON with selection switch\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Range\u003c\/td\u003e\n\u003ctd\u003e1.0 to 5.0 mg\/L (ppm) O₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eAdjustable, from 5 min to 60 min with knob or Disable by wire strap - on real panel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eContinuous ON\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003eBlack anodized aluminum body; front and back with ABS; transparent splash-proof front cover\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Cutout\u003c\/td\u003e\n\u003ctd\u003e141 x 69 mm (5.6 x 2.7'')\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO Probe\u003c\/td\u003e\n\u003ctd\u003eHI 76410\/4 with 4 m cable or HI 76410\/10 with 10 m cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e0 to 20 mA or 4 to 20 mA (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e115 or 230 Vac; ± 10% (user selectable); 60\/50 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-10 to 50 °C (14 to 122 °F); RH 95%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1 kg (2.2 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eThe HI8410 is supplied with mounting brackets and instructions. Probes (not included): HI76410\/4: Galvanic DO probe (fixed) with internal temperature sensor, DIN connector and 4 m (13.1’) cable HI76410\/10: Galvanic DO probe (fixed) with internal temperature sensor, DIN connector and 10 m (32.8’) cable\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI8410\" target=\"_blank\" rel=\"noopener\"\u003eDissolved Oxygen Controller with Extended Range and Analog Output - HI8410\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871406195057,"sku":"HI8410","price":112700.7,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi8410n.jpg?v=1792646455","url":"https:\/\/hannainst.in\/products\/dissolved-oxygen-controller-with-extended-range-and-analog-output-hi8410","provider":"hanna","version":"1.0","type":"link"}