{"product_id":"flat-tip-ph-electrode-for-skin-and-surfaces-with-bnc-connector-hi1413b","title":"Flat Tip pH Electrode for Skin and Surfaces with BNC Connector - HI1413B","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH,  bulb shape,  body material,  type of junction,  type of reference and electrolyte used are just some of the design considerations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe HI1413B uses low temperature (LT) glass,  flat tip bulb,  glass body,  and open junction with viscolene gel electrolyte.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1413B_GPglass_jpg.png\" alt=\"Glass\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLow Temperature Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eThe glass tip uses a special LT glass formulation with a lower resistance of approximately 50 megaohms compared to general purpose (GP) with a resistance of about 100 megaohms. This is beneficial since many food products are stored at low temperatures. As the temperature of the glass decreases in the sample,  the resistance of the LT glass will increase approaching that of GP glass at ambient temperatures. If using GP glass,  the resistance would increase above the optimum resistance for the high impedance input of a pH meter.The HI1413B is suitable to use with samples that measure from 0 to 50℃.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1413B_FlatTip_jpg.png\" alt=\"Flat Tip\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFlat Glass Tip\u003c\/h4\u003e\n\u003cp\u003eA flat tip is recommended to optimize surface contact for measurement on skin,  leather,  paper,  and samples that cannot easily be penetrated.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1413B_GlassBody_jpg.png\" alt=\"glass Body\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGlass Body\u003c\/h4\u003e\n\u003cp\u003eThe glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium,  the steadier the reference potential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1413B_OpenJunction_jpg.png\" alt=\"Open Junction\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eOpen Junction Reference\u003c\/h4\u003e\n\u003cp\u003eSuspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time,  erratic readings,  and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag\/AgCl reference. This interface not only prevents silver from entering the sample,  but also makes it impermeable to clogging,  resulting in a fast response and stable readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/bnc.png\" alt=\"bnc connector\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBNC Connector\u003c\/h4\u003e\n\u003cp\u003eThe HI1413B uses a BNC connector. This type of connector is universal in that it can be used on any pH meter that has the female BNC probe input. Other type of connectors include DIN,  screw type,  T-type,  and 3.5mm to name a few. These types of connectors tend to be proprietary for a particular type of meter and are not interchangeable.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI1413B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e Flat Tip pH Electrode for Skin and Surfaces with BNC Connector - HI1413B\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e pH: 0 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e single, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e viscolene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e flat\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F) - LT\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 110 mm \/ 153.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e emulsions, leather, paper, skin, surface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI1413B\"\u003eFlat Tip pH Electrode for Skin and Surfaces with BNC Connector - HI1413B\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871223906673,"sku":"HI1413B","price":18246.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1413b_2.jpg?v=1792645897","url":"https:\/\/hannainst.in\/products\/flat-tip-ph-electrode-for-skin-and-surfaces-with-bnc-connector-hi1413b","provider":"hanna","version":"1.0","type":"link"}