{"product_id":"halo-glass-body-gel-filled-ph-electrode-with-bluetooth-hi11102","title":"HALO Glass Body Gel Filled pH Electrode with Bluetooth® - HI11102","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eDownload the FREE app and try before you buy!\u003c\/p\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/play.google.com\/store\/apps\/details?id=com.hannainst.hannalab\u0026amp;hl=en\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Google.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e \u003ca href=\"https:\/\/itunes.apple.com\/us\/app\/hanna-lab\/id913755813?ls=1\u0026amp;mt=8\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Apple.png\" alt=\"Download Hanna Lab app\" loading=\"lazy\" style=\"display: inline-block; vertical-align: middle; width: auto; height: 44px; max-width: 100%; border: 0; border-radius: 0; margin: 0 8px 8px 0;\"\u003e\u003c\/a\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11102family.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe HI11102 HALO is a revolutionary pH electrode that incorporates Bluetooth Smart (Bluetooth 4.0) wireless technology with an application specific design. This electrode has many features that makes it ideal for laboratory use. These features include general purpose (GP) glass,  spheric bulb,  integrated temperature sensor,  glass body,  and double reference junction with silver-free gel electrolyte.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11102gpglass.png\" alt=\"\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGeneral Purpose Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eGeneral Purpose (GP) glass,  as the name implies,  is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples that are at ambient temperatures. The HI11102 is suitable to use with samples that measure from -5 to 80℃ (23 to 176℉).\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11102spheric_tip.png\" alt=\"\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSpheric Glass Tip\u003c\/h4\u003e\n\u003cp\u003eThe spheric bulb is for general purpose use within laboratory environments and applications that measure aqueous solutions due to its large surface area. Other tip shapes include conic for penetration and flat tip for surface measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11102tempsensor.png\" alt=\"\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eBuilt-In Temperature Sensor\u003c\/h4\u003e\n\u003cp\u003eHI11102 features a built-in thermistor temperature sensor that is in the tip of the indicating pH electrode. A thermistor temperature sensor provides for a high accuracy temperature reading and should be as close as possible to the indicating pH electrode in order to compensate for the effect that temperature has on the membrane potential as predicted by the Nernst equation. By having an accurate reading it is possible to provide a temperature compensated reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11102diagonal.png\" alt=\"pH electrode\" width=\"749\" height=\"749\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/glass-body-bfa9885d.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eGlass Body\u003c\/h5\u003e\n\u003cp\u003eThe glass body of the HI11102 is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easy to clean. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent,  so the faster thermal equilibrium is reached,  the steadier the reference potential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11102junction.png\" alt=\"\" width=\"150\" height=\"150\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eSingle Ceramic Double Junction Reference\u003c\/h5\u003e\n\u003cp\u003eThe HI11102 is a double junction design. pH electrodes are available as single junction or double junction. See below for a complete description of the differences. The junction also known as a salt bridge is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction allows the gel electrolyte to flow at a rate of 15-20 µL\/hour.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/electrode_fill_solutions_comparison.png\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eConventional electrodes are normally single junction. As depicted by the figure above,  these electrodes have only a single junction between the internal reference wire and the external solution. Under adverse conditions,  such as high pressure,  high temperature,  highly acidic or alkaline solutions,  the positive flow of the electrolyte through the junction is often reversed resulting in the ingress of sample solution into the reference compartment. If this is left unchecked,  the reference electrode can become contaminated,  leading to complete electrode failure. Another potential problem with single junction electrodes is the clogging of the junction due to silver chloride (AgCl) precipitation. Silver can be easily precipitate in samples that contain Tris buffer or heavy metals. When the electrolyte solution makes contact with the sample,  some AgCl will precipitate on the external face of the junction. The result is drifty readings obtained from the sensor.\u003c\/p\u003e\n\u003cp\u003eHanna’s double junction system,  as the name implies,  has two junctions,  only one of which is in contact with the sample as shown in the figure. Under adverse conditions,  the same tendency of sample ingress is evident. However,  as the reference electrode system is separated physically from the intermediate electrolyte area,  the contamination of the electrode is minimized. The likelihood of clogging of the junction is also reduced with a double junction electrode since the outer reference cell uses a fill solution that is “silver-free.” Since there is no silver present,  there is no precipitate that can form to clog the junction.\u003c\/p\u003e\n\u003ch2\u003eHanna Lab App\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes can connect with HI2202 edge\u003csup\u003eblu\u003c\/sup\u003e meter or a compatible Apple or Android device running the Hanna Lab App.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Android-Compatible.jpg\" alt=\"HALOTM - pH Probe with Bluetooth® Smart Technology\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eThe Hanna Lab App turns a compatible Apple or Android device into a full-featured pH meter when used with the Hanna HALO pH probe with Bluetooth Smart technology. Functions include calibration,  measurement,  data logging,  graphing and data sharing. Measurement and logging of pH and temperature at one second intervals start as soon as the probe is connected. Measurements can be displayed alone on the display,  with tabulated data,  or as a graph. The graph can be panned and zoomed with pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/calibration.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFive-Point Calibration\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App incorporates a probe calibration using up to five pH buffers that are automatically recognized and temperature corrected to 25.0℃ during calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo2.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eReal-Time Data\u003c\/h4\u003e\n\u003cp\u003eDisplay of pH and temperature updated every second. Readings are automatically saved to a history file every hour,  limited only by the available memory on the device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/photo3.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFluid,  Dynamic Graphing\u003c\/h4\u003e\n\u003cp\u003eMeasurement can be displayed with tabulated data or a graph on the display. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI11102hand.png\" alt=\"HALO pH probe features\" width=\"578\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003cp\u003eConnecting the HALO probe to the Hanna Lab App is simple. Tap the Bluetooth icon in the top-right corner to view all available HALO probes then press the button on your HALO probe. Select the newly discovered HALO probe from the list of available probes. If a previously associated probe is in discovery mode when the app is opened it will connect to that probe automatically.\u003c\/p\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(200px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/appenabledthm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGLP (Good Laboratory Practice)\u003c\/h4\u003e\n\u003cp\u003eDisplays date and time of current calibration,  probe offset,  and average slope,  along with calibrated buffers,  mV values,  temperature and slopes between each buffer.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-alarm.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eCalibration Reminder \u0026amp; Measurement Alarms\u003c\/h4\u003e\n\u003cp\u003eThe Hanna Lab App alerts you when HALO needs calibration or if a measurement threshold is exceeded.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-share.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLog \u0026amp; Share Data\u003c\/h4\u003e\n\u003cp\u003eSaved log files may be annotated with measurement-specific information. Data can easily be shared via email in CSV format.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-help.png\" alt=\"\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHelp \u0026amp; Tutorials\u003c\/h4\u003e\n\u003cp\u003eDemo probe mode helps you explore features of the Hanna Lab App. General app information,  General HALO information,  pH tutorial,  maintenance tutorial,  and contact information are available in help.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHanna Lab App Features\/Benefits:\u003c\/h4\u003e\n\u003ch5\u003eConnects to HALO electrodes via Bluetooth Smart Technology (Bluetooth 4.0)\u003cbr\u003e\n\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eUp to five-point pH calibration with seven standard pH buffers available\u003c\/strong\u003e \u003cbr\u003e\u003cstrong\u003eCalibration reminder\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\u003cli\u003eAlerts you when HALO needs calibration\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eReal-time data\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays pH and temperature updated every second\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBasic GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration along with probe offset and average slope\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFull GLP\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eDisplays date and time of current calibration,  probe offset and average slope along with calibrated buffers,  mV values,  temperature and slopes between each buffer\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFluid, dynamic graphing\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eMeasurement can be displayed with tabulated data or as a graph. The graph axes may be expanded using pinch-to-zoom technology for enhanced viewing\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eMeasurement alarms\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eAlerts you if the measurement threshold is exceeded\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eOne button sample tagging\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003ePressing either the probe icon in the Hanna Lab App or button on the HALO pH probe will tag sample data for easy reference\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eData-logging with custom annotations\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eSaved log files may be annotated with measurement  specific  information\u003c\/li\u003e\n\u003cli\u003eData is autosaved every hour\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eFour ways to save and share data:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eAll data since last autosave\u003c\/li\u003e\n\u003cli\u003eAnnotations only\u003c\/li\u003e\n\u003cli\u003eAll data within a timed interval\u003c\/li\u003e\n\u003cli\u003eAnnotations only within a timed interval\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch5\u003eShare data via email in CSV format\u003cbr\u003e\u003cbr\u003eHelp and tutorials:\u003c\/h5\u003e\n\u003cul\u003e\n\u003cli\u003eDemo probe mode to help explore features of the Hanna Lab App\u003c\/li\u003e\n\u003cli\u003eGeneral app information\u003c\/li\u003e\n\u003cli\u003eGeneral HALO information\u003c\/li\u003e\n\u003cli\u003epH tutorial\u003c\/li\u003e\n\u003cli\u003eMaintenance tutorial\u003c\/li\u003e\n\u003cli\u003eContact information\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003eCompatibility:\u003c\/h2\u003e\n\u003cp\u003eHALO pH electrodes are compatible with HI2202 edge\u003csup\u003eblu\u003c\/sup\u003e meter and the following devices: \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eAndroid\u003c\/strong\u003e\u003cbr\u003eCompatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e\u003cbr\u003e\u003cstrong\u003eiOS\u003c\/strong\u003e\u003cbr\u003eiPad (3rd generation or newer)\u003cbr\u003eiPhone (4S or newer)\u003cbr\u003eiPod Touch (5th generation or newer)\u003cbr\u003e\u003cbr\u003eInformation about which products have Bluetooth Smart Technology (4.0),  also known as low energy (LE),  can be found \u003ca href=\"https:\/\/en.wikipedia.org\/wiki\/List_of_iOS_devices\"\u003ehere\u003c\/a\u003e.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003ca href=\"\/\/fast.wistia.net\/embed\/iframe\/v1yd9ivxgc?popover=true\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/40e78888f8bf4b55edc940174475d319898347de.jpg\" alt=\"\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/a\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch2 style=\"margin-top: 0;\"\u003eVideo\u003c\/h2\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI11102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e HALO Glass Body Gel Filled pH Electrode with Bluetooth\u003csup\u003e®\u003c\/sup\u003e - HI11102\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e pH: 0 to 12\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e double, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e ceramic, single\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e gel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e spheric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e -5 to 80°C (23 to 176°F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 183 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e Bluetooth Smart (Bluetooth 4.0), 10 m (33') range\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e CR2032 3V lithium ion \/ approximately 500 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e laboratory general purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e Environment: 0.0 to 50.0°C (32.0 to 122.0°F), electronic module is not waterproof\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRange\u003c\/td\u003e\n\u003ctd\u003e -2.000 to 16.000 pH \/ ±800 mV \/ -20.0 to 120.0 ºC *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResolution\u003c\/td\u003e\n\u003ctd\u003e 0.1, 0.01, 0.001 pH \/ 1, 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAccuracy (@25ºC\/77ºF)\u003c\/td\u003e\n\u003ctd\u003e ±0.005 pH \/ ±0.3 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Points\u003c\/td\u003e\n\u003ctd\u003e Up to five points with seven standard buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Buffers\u003c\/td\u003e\n\u003ctd\u003e 1.68, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003e Automatic from -5.0 to 100.0 ºC \/ 23.0 to 212.0 ºF *(will be reduced to actual probe\/sensor limits)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatibility\/System Requirements\u003c\/td\u003e\n\u003ctd\u003e Android: Compatible with most devices equipped with Bluetooth Smart Technology (Bluetooth 4.0) and running Android 4.3 or later. \u003cbr\u003e iOS: Compatible with iPad (3rd generation or newer), iPhone (4S or newer), iPod Touch (5th generation or newer)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDownload Information\u003c\/td\u003e\n\u003ctd\u003e Hanna Lab App is available free from the Play Store or App Store\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI11102 (HALO) is supplied with storage solution, cleaning solution, pH 7.01 buffer solution, pH 4.01 buffer solution, battery, quality certificate and instruction sheet.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI11102\"\u003eHALO Glass Body Gel Filled pH Electrode with Bluetooth\u003csup\u003e®\u003c\/sup\u003e - HI11102\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871198609777,"sku":"HI11102","price":33448.95,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/halo-n-081214_open-battery_2.jpg?v=1792645866","url":"https:\/\/hannainst.in\/products\/halo-glass-body-gel-filled-ph-electrode-with-bluetooth-hi11102","provider":"hanna","version":"1.0","type":"link"}