{"product_id":"hi6000-2-ph-orp-ise-module-is-designed-to-be-used-with-the-hi6000-multiparameter-modular-system","title":"HI6000-2 (pH\/ORP\/ISE) module is designed to be used with the HI6000 Multiparameter Modular System","description":"\u003cp\u003eMeasurement\u003cbr\u003e\n• Measure pH, mV, or ISE with temperature (HI6000-2)\u003cbr\u003e\n• Application-specific profiles allow quick and direct measurement without the need to\u003cbr\u003e\nupdate the sensor and system settings\u003cbr\u003e\n• Active log during measurement\u003cbr\u003e\n• Measurement stability indicator (using the Stability Criteria setting)\u003cbr\u003e\n• Reading modes:\u003cbr\u003e\n• Direct and direct\/autohold\u003cbr\u003e\n• Known Addition, Known Subtraction, Analyte Addiiton, Analyte Subtration (HI6000-2)\u003cbr\u003e\n• Temperature compensation can be Automatic (using temperature probe) or set manually\u003c\/p\u003e\n\u003cp\u003e•Audible and\/or alarm messages for measurements outside of predefined limits\u003cbr\u003e\n•Galvanic isolation for pH\/ORP measurement\u003cbr\u003e\nCalibration\u003cbr\u003e\n•pH calibration using\u003cbr\u003e\n•Up to five Hanna Instruments pH buffers (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01 and\u003cbr\u003e\n12.45)\u003cbr\u003e\n•Up to five custom buffers\u003cbr\u003e\n•mV calibration using a single point to calibrate offset.\u003cbr\u003e\n•ISE calibration using up to five nominal standard values (e.g. for ppm: 0.010, 0.100, 1.00,\u003cbr\u003e\n10.0, 100, 1000, 10000 ppm) and\/or up to five custom solutions (user supplied)\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI6000-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI6000-1 pH\/ORP Module designed to be used with the HI6000 Multiparameter Modular System. - HI6000-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; -2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature\ncompensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic or manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration\npoints\u003c\/td\u003e\n\u003ctd\u003eup to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType\u003c\/td\u003e\n\u003ctd\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStandard\nbuffers\u003c\/td\u003e\n\u003ctd\u003eHanna and NIST pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18,\n10.01, 12.45\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom buffers\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCustom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e1st calibration\npoint\u003c\/td\u003e\n\u003ctd\u003eOffset or point (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIsopotential\npoint\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Isopotential\npoint\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e−2000.0 mV to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point offset, ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Range\u003c\/td\u003e\n\u003ctd\u003e1.0×10-5 to 300.0 ppt (g\/L or\nmg\/mL)\n5.0×10-3 to 1.0×105 ppm\n(mg\/L or µg\/mL)\n1.0 to 5.0×107 ppb (µg\/L)\n1.0×10-7 to 10.0 M (mol\/L)\n1.0×10-4 to 1.0×104 mmol\/L\n1.0×10-6 to 60.0 %w\/v\n5.0×10-7 to 5.0×107 user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Resolution\u003c\/td\u003e\n\u003ctd\u003e1, 2, 3 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5% (monovalent ions)\n±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration points\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Calibration type\u003c\/td\u003e\n\u003ctd\u003eAll standards\nStandard group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Standards\u003c\/td\u003e\n\u003ctd\u003e7 standard solutions available\nfor each concentration unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Custom standards\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eISE Custom group\u003c\/td\u003e\n\u003ctd\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range*\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C\n-4.0 to 248.0 °F\n253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\n0.1 °F\n0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 °C\n±0.4 °F\n±0.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode\u003c\/td\u003e\n\u003ctd\u003eDirect; Direct\/Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Basic\u003c\/td\u003e\n\u003ctd\u003eMeasurement data\nMeasurement profile (if enabled)\nStability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Simple GLP\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nLast calibration date, slope, offset (pH, Rel. mV - ISE\nonly)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Full GLP\u003c\/td\u003e\n\u003ctd\u003eSimple GLP information\nCalibration point details (pH \u0026amp; ISE)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Graph\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nMeasurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReading mode Table\u003c\/td\u003e\n\u003ctd\u003eBasic view information\nTable with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI6000-02 (EU power plug) is supplied with HI764060\u003cbr\u003e\nelectrode holder; 24 VDC power adapter; USB-C to USB-A cable; quick reference guide and\u003cbr\u003e\ninstrument quality certificate.\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460589937,"sku":"HI6000-2","price":37647.45,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6000-2-3448x3448-3a07ca94-9c25-4288-8092-e3ab26c79ca0-scaled.jpg?v=1792646966","url":"https:\/\/hannainst.in\/products\/hi6000-2-ph-orp-ise-module-is-designed-to-be-used-with-the-hi6000-multiparameter-modular-system","provider":"hanna","version":"1.0","type":"link"}