{"product_id":"iris-visible-spectrophotometer-with-method-identification-via-barcode-reader-hi802","title":"iris® Visible Spectrophotometer with Method Identification via Barcode  Reader - HI802-02","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI802_4-2438x2438-385b52ac-08da-466b-bf6f-87c6c4e9ede2.jpg\" alt=\"Vial barcode reader for HI802\" width=\"594\" height=\"594\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eMethod identification\u003c\/p\u003e\n\u003ch5\u003eVial barcode reader\u003c\/h5\u003e\n\u003cp\u003eAutomatic method identification of barcoded sample vials is an exciting feature of HI802. The HI802 visible spectrophotometer scans an inserted barcoded vial and automatically detects both method type and method range, significantly reducing the risk of errors and aiding measurement procedure.\u003c\/p\u003e\n\u003ch5\u003eVial rotation\u003c\/h5\u003e\n\u003cp\u003eVial rotation during measurement allows for method identification and for a number of absorbance readings. The instrument then converts the readings to concentration units and the result is shown on the LCD display. This rotational averaging of signals during measurement (with the lamp on) ensures improved method accuracy.\nShared single-zero measurement.Use of a single-zero measurement across multiple vial methods where blank correction is done with DI water. This ensures that sample features, rather than instrument changes, are\nreflected in the instrument’s measurements and contributes to ease of use and stable readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI802_8-5168x3448-bfb651bf-1f2a-4c2e-8f9c-f5b939804630-scaled.jpg\" alt=\"iris® Visible Spectrophotometer with Method Identification via Barcode Reader - HI802\" width=\"2560\" height=\"1708\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003eFeatures\u003c\/p\u003e\n\u003ch5\u003eAdvanced split–beam optical system\u003c\/h5\u003e\n\u003cp\u003eIn a spectrophotometer the optical system is the heart of the instrument. Ensuring that the optical system is built with the best design and highest quality materials will guarantee accurate readings and a long life for the meter. When developing this meter our research and development team payed special attention to details and combined many small improvements to a typical spectrophotometer design to create a portable meter with unprecedented performance.\u003c\/p\u003e\n\u003ch5\u003eSpectral range\u003c\/h5\u003e\n\u003cp\u003eThe meter features a spectral range of 340nm to 900nm allowing for a wide selection of analytical methods. The flexibility of this range permits compliance with many methods from regulatory organizations and associations for a variety of applications.\u003c\/p\u003e\n\u003ch5\u003eReplaceable tungsten–halogen lamp\u003c\/h5\u003e\n\u003cp\u003eTo be able to measure in a wide variety of wavelengths a broadband light source is necessary. In the iris® visible spectrophotometer, this is accomplished by a tungsten–halogen lamp. As these lamps do not last indefinitely, it is necessary to change them throughout the life of the meter. The pre–alignment of the lighting fixture guarantees that the bulb is in the same position every time it is changed. This generates peace of mind as there is no need to worry about realigning the light source.\u003c\/p\u003e\n\u003ch5\u003eConcave grating\u003c\/h5\u003e\n\u003cp\u003eThis element of the optical system is what generates the spectrum of light. When the light from the tungsten lamp hits the grating it is met with interference coatings that turn the polychromatic white light into a rainbow. This rainbow contains dispersed light at all wavelengths in the visible spectrum. The rotation of this grating is what allows for a specific wavelength to be selected. This ability is one of the biggest differences between a spectrophotometer and a photometer. The concave grating which accomplishes this is superior to other types of diffraction, such as prisms, as it minimizes stray light generated and has constant bandwidth. It also combines elements of the optical system that would typically be separate, for example if a flat grating was used a concave mirror would need to be added in order to refocus the light. The combination of these two pieces creates greater efficiency and a smaller optical system to yield a more compact portable meter.\u003c\/p\u003e\n\u003ch5\u003eBeam splitter\u003c\/h5\u003e\n\u003cp\u003eThe beam splitter is added to the optical system for use with a reference detector to ensure that the measurement compensates for any drift in the light source. It works by splitting the light emitted by the tungsten lamp into two beams and sending one beam of light to the reference detector that measures intensity. If there are any fluctuations in the light source the meter detects this and compensates through a mathematical calculation. The reference detector also saves battery life and leads to improved speed of the meter as the lamp doesn’t\nhave to warm up prior to use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eiris® Visible Spectrophotometer with Method Identification via Barcode Reader - HI802\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength range\u003c\/td\u003e\n\u003ctd\u003e340 to 900 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength resolution\u003c\/td\u003e\n\u003ctd\u003e1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 3.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometric accuracy\u003c\/td\u003e\n\u003ctd\u003e5 mAbs at 0.000 to 0.500 Abs,\n1 % at 0.500 to 3.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement mode\u003c\/td\u003e\n\u003ctd\u003eTransmittance (%), absorbance and concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSample cell\u003c\/td\u003e\n\u003ctd\u003e10 mm square, 50 mm rectangular,\n16 mm round, 22 mm round, 13 mm round (vial) with barcode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength selection\u003c\/td\u003e\n\u003ctd\u003eAutomatic, based on the selected method (editable for user\nmethods only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLight source\u003c\/td\u003e\n\u003ctd\u003eTungsten halogen lamp\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOptical system\u003c\/td\u003e\n\u003ctd\u003eSplit beam\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWavelength calibration\u003c\/td\u003e\n\u003ctd\u003eInternal, automatic at power-on (with visual feedback)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStray light\u003c\/td\u003e\n\u003ctd\u003e\u0026lt;0.1 % T at 340 nm with NaNO₂\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSpectral bandwidth\u003c\/td\u003e\n\u003ctd\u003e5 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of methods\u003c\/td\u003e\n\u003ctd\u003eUp to 150 factory (103 pre-loaded), up to 100 user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eData points stored\u003c\/td\u003e\n\u003ctd\u003e9999 measured values\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eExport capability\u003c\/td\u003e\n\u003ctd\u003ecsv file format, pdf file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003e1x USB A (mass storage host), 1x USB B (mass storage device)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery life\u003c\/td\u003e\n\u003ctd\u003e3000 measurements or 8 hours*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower supply\u003c\/td\u003e\n\u003ctd\u003e15 Vdc power adapter, 10.8 Vdc Li-ion rechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F), 0 to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e155 x 205 x 322 mm (6.1 x 8.0 x 12.6\")\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e3 kg (6.6 Ibs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI802-01 (115V) and HI802-02 (230V) is supplied with sample cuvette and cap,\u003cbr\u003e\n22 mm (4 pcs.), cuvette adapter (3 pcs.), vial adapter with barcode reading feature ,\u003cbr\u003e\ncloth for wiping cuvettes, scissors, USB cable, 15 VDC power adapter, USB flash drive,\u003cbr\u003e\ninstrument quality certificate, and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI802\" target=\"_blank\" rel=\"noopener\"\u003e iris® Visible Spectrophotometer with Method Identification via Barcode Reader - HI802\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871459443057,"sku":"HI802-02","price":430920.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI802_Cuvette-22mm-2100x2100-5d91fb98-b9eb-4b18-b2b3-84854b9f7a4e.jpg?v=1792646960","url":"https:\/\/hannainst.in\/products\/iris-visible-spectrophotometer-with-method-identification-via-barcode-reader-hi802","provider":"hanna","version":"1.0","type":"link"}