{"product_id":"multiparameter-bluetooth-portable-ph-ec-turbidity-opdo-meter-hi98594","title":"Multiparameter Bluetooth® Portable pH\/EC\/Turbidity\/OPDO® Meter - HI98594","description":"\u003ch5\u003eFeatures\u003c\/h5\u003e\n\u003cp\u003e\u003cstrong\u003eMeasurements\u003c\/strong\u003e\u003cbr\u003e\nHI98594 can display from 1 to 14 parameters on the high contrast backlit LCD. The pH, EC and\u003cbr\u003e\nDO measurements are automatically compensated for temperature variations. Dissolved\u003cbr\u003e\noxygen concentration measurements are automatically compensated for barometric pressure\u003cbr\u003e\nand salinity.\u003cbr\u003e\n\u003cstrong\u003eData Logging\u003c\/strong\u003e\u003cbr\u003e\nHI98594 can be used to log one data point or continuously log at selected time intervals. All\u003cbr\u003e\nlogs have the option to store data into a named lot and the ability to add remarks. Both help to\u003cbr\u003e\nprovide for meaningful data including notes on local environmental conditions.\u003cbr\u003e\nDual Power Source\u003cbr\u003e\nThe meter operates on a built-in lithium-ion battery. When the rechargeable battery is low\u003cbr\u003e\nthe meter will automatically switch to the 1.5 AA alkaline batteries.\u003cbr\u003e\n\u003cstrong\u003eQuick-Calibration\u003c\/strong\u003e\u003cbr\u003e\nQuick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved\u003cbr\u003e\noxygen. Standard calibration options are available including pH up to three points,\u003cbr\u003e\nconductivity at one point, turbidity with 3 provided standards and dissolved oxygen up to two\u003cbr\u003e\npoints.\u003cbr\u003e\n\u003cstrong\u003eGLP Data\u003c\/strong\u003e\u003cbr\u003e\nCalibration information is captured along with time and date stamp. Information includes\u003cbr\u003e\ncalibration values along with other values that have an impact on the measurement. GLP data\u003cbr\u003e\nis stored with logged data.\u003cbr\u003e\n\u003cstrong\u003eBluetooth® 5.0 Connectivity and Hanna Lab App Compatibility\u003c\/strong\u003e\u003cbr\u003e\nHI98594 offers the ability to connect wirelessly to a smart device running the Hanna Lap App.\u003cbr\u003e\nUsing the app, log lots can be e-mailed or downloaded for review.\u003cbr\u003e\n\u003cstrong\u003eShare\u003c\/strong\u003e\u003cbr\u003e\nLogs can be shared as a .CSV or PDF.\u003cbr\u003e\n\u003cstrong\u003eGLP\u003c\/strong\u003e\u003cbr\u003e\nComprehensive GLP data can be reviewed for all parameters when the logged data is\u003cbr\u003e\ndownloaded to a smart device.\u003cbr\u003e\n\u003cstrong\u003eUnit Selection\u003c\/strong\u003e\u003cbr\u003e\nWhen reviewing data on a smart device there is an option to select the measurement units to\u003cbr\u003e\nbe displayed independently of the meter settings.\u003cbr\u003e\n\u003cstrong\u003eData Graphing\u003c\/strong\u003e\u003cbr\u003e\nFor trend analysis the Hanna Lab App offers the option to graph logged data.\u003cbr\u003e\n\u003cstrong\u003eMulti-function Sensor\u003c\/strong\u003e\u003cbr\u003e\nPre-installed Sensors\u003cbr\u003e\nThe HI7698594 is supplied with pre-installed pH\/ORP, EC\/Turbidity and optical DO sensors\u003cbr\u003e\n\u003cstrong\u003eQuick sensor replacement\u003c\/strong\u003e\u003cbr\u003e\nSensor replacement is quick and easy with field replaceable, screw type connectors and are\u003cbr\u003e\ncolor coded for easy identification. These meters automatically recognize sensors.\u003cbr\u003e\n\u003cstrong\u003eOptical Dissolved Oxygen Smart Caps\u003c\/strong\u003e\u003cbr\u003e\nThe optical dissolved oxygen sensor uses a smart cap that has an RFID tag that stores\u003cbr\u003e\ncalibration coefficients unique to each cap. The RFID keeps track of the age of the cap and\u003cbr\u003e\nalerts the user when it should be replaced.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI98594\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eMultiparameter Bluetooth® Portable pH\/EC\/Turbidity\/OPDO® Meter - HI98594\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH* \/ ±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH \/ 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH \/ ±1.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH \/ mV Calibration\u003c\/td\u003e\n\u003ctd\u003e•One point using HI9828-20 Quick calibration solution\n•Up to three points using pH 4.01, pH 6.86, pH 7.01, pH\n9.18, pH 10.01 standard buffers and one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0 % saturation\n0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 % saturation\n0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e•±1.5 % of reading from 0.0 to 200.0 % saturation\n•±5 % of reading from 200.0 to 500.0 % saturation\n•±1.5 % of reading from 0.00 to 20.00 mg\/L\n•±5 % of reading from 20.00 to 50.00 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDO calibration\u003c\/td\u003e\n\u003ctd\u003e•One point, quick calibration in water-saturated air\n•One or two points, at 100 % and 0 %\n•One point, using a custom solution (% saturation or mg\/L )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePressure compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic 450 to 850 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm\n0 to 400 mS\/cm (absolute)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003e•Manual\n1 μS\/cm\n0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm\n•Automatic\n1 μS\/cm from 0 to 9999 μS\/cm\n0.01 mS\/cm from 10.00 to 99.99 mS\/cm\n0.1 mS\/cm from 100.0 to 400.0 mS\/cm\n•Automatic (mS\/cm)\n0.001 mS\/cm from 0.000 to 9.999 mS\/cm\n0.01 mS\/cm from 10.00 to 99.99 mS\/cm\n0.1 mS\/cm from 100.0 to 400.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003e•One point using HI9828-20 Quick calibration solution\n•One point using 84 μS\/cm, 1413 μS\/cm, 5.00 mS\/cm,\n12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm standard\nsolutions or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω·cm\n0 to 1000.0 kΩ·cm\n0 to 1.0000 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 Ω·cm\n0.1 kΩ·cm\n0.0001 MΩ·cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range*\u003c\/td\u003e\n\u003ctd\u003e0 to 400000 ppm (mg\/L)\n(the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e•Manual\n1 ppm (mg\/L)\n0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L)\n•Automatic\n1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L)\n0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L)\n0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L)\n•Automatic: ppt (g\/L)\n0.001 ppt (g\/L) from 0.000 to 9.999 ppt (g\/L)\n0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L)\n0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 % of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calilbration\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity Calibration\u003c\/td\u003e\n\u003ctd\u003eOne point, using a custom solution\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt , σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt , σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSeawater Sigma Calibration\u003c\/td\u003e\n\u003ctd\u003eBased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 FNU\n100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 FNU from 0.0 to 99.9 FNU\n1 FNU from 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 FNU or ±2 % of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Calibration\/td\u0026gt;\u003c\/td\u003e\n\u003ctd\u003eAutomatic\nUp to three points using 0 FNU, 20 FNU, 200 FNU, and a\ncustom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Range\u003c\/td\u003e\n\u003ctd\u003e450.0 to 850.0 mmHg\n17.72 to 33.46 inHg\n600.0 to 1133.2 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mmHg\n0.01 inHg\n0.1 mbar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3.0 mmHg within ±15 °C from calibration temperature\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAtmospheric pressure Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e−5.00 to 50.00 °C\n23.00 to 122.00 °F\n268.15 to 323.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 °C\n0.01 °F\n0.01 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15 °C\n±0.27 °F\n±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Temperature compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Logging memory\u003c\/td\u003e\n\u003ctd\u003e•Interval logging 50000 records\n•Log-on-demand (all parameters) 20000 records\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Logging interval\u003c\/td\u003e\n\u003ctd\u003e1 second to 3 hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - USB-C (Host) functions\u003c\/td\u003e\n\u003ctd\u003eMass-storage host\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - USB-C (Device) functions\u003c\/td\u003e\n\u003ctd\u003eMass-storage device\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Protection rating\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Environment\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F); RH 100 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Battery type\u003c\/td\u003e\n\u003ctd\u003e4 x 1.5 V AA alkaline batteries\n1 x internal, Li-ion rechargeable battery\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Battery life\u003c\/td\u003e\n\u003ctd\u003e≈ 126 hours\n90 hours using alkaline AA batteries\n36 hours using Li-ion battery**\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Dimensions\u003c\/td\u003e\n\u003ctd\u003e185 x 93 x 35.2 mm (7.3 x 3.6 x 1.4”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAdditional specifications - Weight\u003c\/td\u003e\n\u003ctd\u003e435 g (13.3 oz)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eAll HI98594 models are supplied with:\u003cbr\u003e\nHI7698594 Multisensor probe\u003cbr\u003e\nHI7698296 Protective probe shield\u003cbr\u003e\nHI76984942 Probe maintenance kit\u003cbr\u003e\nHI7698194-1 pH \/ ORP sensor\u003cbr\u003e\nHI7698594-4 EC \/ Turbidity sensor\u003cbr\u003e\nHI7698594-5 Optical DO sensor\u003cbr\u003e\nHI764113-1 DO Smart Cap with o-ring\u003c\/p\u003e\n\u003cp\u003eHI7698293 Long calibration beaker\u003cbr\u003e\nHI9828-25 Quick calibration standard solution (500 mL)\u003cbr\u003e\nHI7040 Zero oxygen solution set (120 mL)\u003cbr\u003e\nHI9829-16 0 FNU calibration solution (230 mL)\u003cbr\u003e\nHI9829-17 20 FNU calibration solution (230 mL)\u003cbr\u003e\nHI9829-18 200 FNU calibration solution (230 mL)\u003cbr\u003e\nHI710034 Protective rubber boot\u003cbr\u003e\nHI920016 USB cable\u003cbr\u003e\n1.5V AA alkaline batteries (4 pieces)\u003cbr\u003e\nQuality certificates (instrument, probe, DO Smart Cap)\u003cbr\u003e\nQuick reference guide\u003c\/p\u003e\n\u003cp\u003eHI98594 is supplied with multisensor probe with 4m (13.1’) cable\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI98309\" target=\"_blank\" rel=\"noopener\"\u003eMultiparameter Bluetooth® Portable pH\/EC\/Turbidity\/OPDO® Meter - HI98594\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461081457,"sku":"HI98594","price":444386.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI98594-Front-Boot-4372x4373-576a180c-4bf8-43dd-8d9f-23605bc733c7-1-scaled.jpg?v=1792646974","url":"https:\/\/hannainst.in\/products\/multiparameter-bluetooth-portable-ph-ec-turbidity-opdo-meter-hi98594","provider":"hanna","version":"1.0","type":"link"}