{"product_id":"multiparameter-ph-ise-ec-do-turbidity-waterproof-meter-with-gps-option-hi9829","title":"Multiparameter pH\/ISE\/EC\/DO\/Turbidity Waterproof Meter with GPS option – HI9829-02","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/gps9829b.jpg\" alt=\"GPS\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eMeter with or without GPS\u003c\/h4\u003e\n\u003ch4\u003eBuilt in GPS Receiver\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003e12 channel GPS receiver and antenna\u003c\/li\u003e\n\u003cli\u003eTracks location using satellites to within 30 feet\u003c\/li\u003e\n\u003cli\u003eLatitude and longitude recorded with readings\u003c\/li\u003e\n\u003cli\u003eLocation naming for GPS coordinates\u003c\/li\u003e\n\u003cli\u003eDistance from current location to stored location\u003c\/li\u003e\n\u003cli\u003eHi929829 software supplied integrates data collected with Google™ maps\u003cul\u003e\n\u003cli\u003eMeasurement readings including GPS coordinates\u003c\/li\u003e\n\u003cli\u003eDate and time\u003c\/li\u003e\n\u003cli\u003eNamed locations and remarks\u003c\/li\u003e\n\u003cli\u003eSample number\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eGoogle™ maps is a registered trademark of Google™, Inc. HANNA Instruments® has no affiliation with Google™.\u003c\/p\u003e\n\u003ch4\u003eTwo probes to choose from (Basic or Logging)\u003c\/h4\u003e\n\u003cp\u003eThe HI7609829 (basic) and HI7629829 (logging) are multiparameter probes for use with the HI9829 portable meter.  It is an option to choose which probe will be supplied with the HI9829.   By default the HI9829 and corresponding probe will be supplied with a pH\/ORP, conductivity and dissolved oxygen sensors. Either probe can be upgraded to measure turbidity with  a turbidity\/conductivity sensor.\u003c\/p\u003e\n\u003ch4\u003eHI7609829 Basic Probe\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eDigital probe that is less than 2 inches in diameter\u003c\/li\u003e\n\u003cli\u003e3 color-coded sensor inputs\u003c\/li\u003e\n\u003cli\u003eIP68 rating for continuous immersion in water\u003c\/li\u003e\n\u003cli\u003eMultistrand –mulitconductor cable rated for 150 lbs (intermittent use)\u003c\/li\u003e\n\u003cli\u003eAvailable with 4, 10, or 20 meter cable\u003c\/li\u003e\n\u003cli\u003eWeighted shield protects all sensors\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7609829-short.jpg\" alt=\"HI7609829 probe without logging\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHI7629829 Autonomously Logging Probe\u003c\/h4\u003e\n\u003cul\u003e\n\u003cli\u003eSame as basic probe but with logging capability\u003c\/li\u003e\n\u003cli\u003eLogs data independent of HI9829 meter\u003c\/li\u003e\n\u003cli\u003eOperates on 4 “AA” batteries for up to 70 days*\u003c\/li\u003e\n\u003cli\u003eStores up to 140, 000 single parameter readings or 35, 000 for all parameters\u003c\/li\u003e\n\u003cli\u003eLogs data from 1 second to 3 hours\u003c\/li\u003e\n\u003cli\u003eChoose to be supplied with EC or EC\/Turbidity sensor\u003c\/li\u003e\n\u003cli\u003eSupplied with USB cable for direct connection to Window’s compatible PC\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003e*All channels logging at 10 minute intervals with no averaging\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7629829-long.jpg\" alt=\"HI7629829 logging probe\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\u003ch4 style=\"margin-top: 0;\"\u003eColor Coded, Field Replaceable Sensors\u003c\/h4\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"overflow-x: auto; margin: 0 0 32px;\"\u003e\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"5\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sensors_01.jpg\" alt=\"\" width=\"1200\" height=\"639\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-2-galvanic-do-sensor-for-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/DO-sensor.jpg\" alt=\"\" width=\"202\" height=\"32\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-0-double-junction-ph-sensor-for-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/pH-sensor.jpg\" alt=\"\" width=\"201\" height=\"32\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-10-ammonium-ion-selective-electrode-for-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Ammonium-ISE-sensor.jpg\" alt=\"\" width=\"280\" height=\"32\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-3-conductivity-sensor-for-the-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/EC-Sensor.jpg\" alt=\"\" width=\"226\" height=\"32\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-4-conductivity-and-turbidity-sensor-for-the-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Turbidity-Sensor.jpg\" alt=\"\" width=\"291\" height=\"32\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"3\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sensors_07.jpg\" alt=\"\" width=\"202\" height=\"83\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-1-double-junction-ph-orp-sensor-for-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/pHORP-sensor.jpg\" alt=\"\" width=\"201\" height=\"31\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-11-chloride-ion-selective-electrode-for-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Chloride-ISE.jpg\" alt=\"\" width=\"280\" height=\"31\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003ctd colspan=\"2\" rowspan=\"3\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sensors_10.jpg\" alt=\"\" width=\"517\" height=\"83\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd rowspan=\"2\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sensors_11.jpg\" alt=\"\" width=\"201\" height=\"52\"\u003e\u003c\/td\u003e\n\u003ctd\u003e\u003ca href=\"\/hi7609829-12-nitrate-ion-selective-electrode-for-hi9829-multiparameter-portable-meter.html\"\u003e \u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Nitrate-ISE.jpg\" alt=\"\" width=\"280\" height=\"31\" border=\"0\"\u003e\u003c\/a\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/sensors_13.jpg\" alt=\"\" width=\"280\" height=\"21\"\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\n\u003cdiv style=\"text-align: center; margin: 0 0 48px;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI9829_v2_multiparameter_pH_ORP_mv_ISE_meter_GPS_logging.jpg\" alt=\"HI9829 multiparameter pH meter\" loading=\"lazy\" style=\"display: block; max-width: min(100%, 640px); height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI9829-In-Case_1200.jpg\" alt=\"HI9829 multiparameter pH meter (in carrying case)\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003cp\u003e\u003cstrong\u003eWaterproof Protection \u003c\/strong\u003e– The meter is enclosed in an IP67 rated waterproof casing and can withstand immersion in water at a depth of 1 m for up to 30 minutes. The probe features an IP68 rating for continuous immersion in water.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eBacklit Dot Matrix LCD Display \u003c\/strong\u003e– The HI9829 features a backlit graphic LCD with on-screen help and the capability to display up to twelve parameters simultaneously. The graphic display allows for the use of virtual keys to provide for an intuitive user interface.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eIntuitive Keypad\u003c\/strong\u003e – The fitted rubber keypad has dedicated keys for power, backlight, up\/down arrows, help and alphanumeric characters. The meter also features two virtual soft keys that navigate the user through the configuration of each parameter, meter setup, and logging of data. The interface is intuitive for any user’s level of experience.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eDedicated Help Key\u003c\/strong\u003e – Contextual help is always available through a dedicated “HELP” key. Clear tutorial messages and directions are available on-screen to quickly and easily guide users through setup and calibration.  The help information displayed is relative to the setting\/option being viewed.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAuto-sensor Recognition\u003c\/strong\u003e – The probe and meter automatically recognize the sensors that are connected. Any ports not used on the probe will not have the parameter displayed or be configurable.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic temperature compensation\u003c\/strong\u003e – Integrated temperature sensor allows for automatic temperature compensation of pH, conductivity, and dissolved oxygen measurements.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eAutomatic Barometric Pressure Compensation\u003c\/strong\u003e – The meter features a built-in barometer with user-selectable units for dissolved oxygen pressure compensation.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eQuick Calibration\u003c\/strong\u003e – Quick Calibration provides a speedy, single point calibration for pH, conductivity, and dissolved oxygen. Standard calibration options are available including pH up to three points, Conductivity at one point and dissolved oxygen up to two points.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGLP Data\u003c\/strong\u003e – HI9829 includes a GLP feature thatallows users to view calibration data and calibration expiration information at the touch of a key. Calibration data includes date, time, buffers\/standards used for calibration, and slope characteristics.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eData Logging\u003c\/strong\u003e – The HI9829 allows users to store up to 44, 000 continuous or log-on-demand  samples with logging intervals from one second to three hours.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eGraphing Capability\u003c\/strong\u003e – Trend graphing with sample date and time stamp may be viewed on the display or transferred to a pc.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePC Connectivity\u003c\/strong\u003e – Logged data can be transferred to a Windows compatible PC with the included HI7698291 USB adapter and HI929829 software.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eLong Battery Life\u003c\/strong\u003e – The display of the meter has a battery icon indicator to show the remaining power. The meter is supplied with four 1.5V “C “ NiMH rechargeable batteries that provide up to 140 hours of battery life*\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRugged thermoformed carrying case\u003c\/strong\u003e – The HI9829 meter, probe, and all accessories are supplied in a rugged carrying case designed to provide years of use. The inside compartment of the carrying case is thermoformed to securely hold and protect all of the components.\u003c\/p\u003e\n\u003cp\u003e* Without GPS or turbidity measurements\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch2 style=\"margin: 0 0 24px; text-align: center;\"\u003eOn-screen Features\u003c\/h2\u003e\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI9829_Screen_GPS_Diagnostics.jpg\" alt=\"GPS option\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGPS Option\u003c\/h4\u003e\n\u003cp\u003eThe meter features an internal 12 channel GPS receiver and antenna that calculates its position to track locations along with measurement data.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI9829_Screen_GPS_Quick_Cal.jpg\" alt=\"calibration\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eQuick Calibration\u003c\/h4\u003e\n\u003cp\u003eThe quick calibration feature allows for a single point calibration for pH, conductivity, and dissolved oxygen all in few simple steps.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: center; text-align: center;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI9829_Screen_Graphing.jpg\" alt=\"graphing\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGraphing Capability\u003c\/h4\u003e\n\u003cp\u003eTrend graphing with sample date and time may be viewed on the display or transferred to PC.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/fast_tracker9829.jpg\" alt=\"fast tracker\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eFast Tracker™—Tag Identification System\u003c\/h5\u003e\n\u003cp\u003eHANNA’s Fact Tracker™—Tag Identification System simplifies test logging. iButtons with a unique ID can be installed at various sampling sites. When the matching connector on the meter contacts the location button, measurements are logged and labeled with the alphanumeric user-entered location ID. Location, date, time and measurements are logged into the meter which can be transferred to a PC. The Fast Tracker™ system complements the GPS for ultimate tracking.\u003c\/p\u003e\n\u003ch5\u003eiButton. Tags are Easy to Install\u003c\/h5\u003e\n\u003cp\u003eInstall the optional TAGs near your sampling points for quick and easy iButton. readings. Each TAG contains a computer chip with a unique identification code encased in stainless steel. You can install a practically unlimited amount of TAGs. Additional TAGs can be ordered for all of your traceability requirements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI9829-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eHI9829 Multiparameter pH\/ISE\/EC\/DO\/Turbidity Waterproof Meter with GPS option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one, two, or three points with automatic recognition of five standard buffers (pH 4.01, 6.86, 7.01, 9.18, 10.01) or one custom buffer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e±2000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point (relative mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Range\u003c\/td\u003e\n\u003ctd\u003e±600.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Range\u003c\/td\u003e\n\u003ctd\u003e0 to 200 mS\/cm (absolute EC up to 400 mS\/cm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Resolution\u003c\/td\u003e\n\u003ctd\u003eManual: 1 µS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm; 1 mS\/cm, Automatic: 1 µS\/cm from 0 to 9999 µS\/cm; 0.01 mS\/cm from 10.00 to 99.99 mS\/cm; 0.1 mS\/cm from 100.0 to 400.0 mS\/cm, Automatic (mS\/cm): 0.001 mS\/cm from 0.000 to 9.999 mS\/cm; 0.01 mS\/cm from 10.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 µS\/cm whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic single point, with six standard solutions (84 µS\/cm, 1413 µS\/cm, 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm) or custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0 to 400000 ppm (mg\/L); (the maximum value depends on the TDS factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003eManual: 1 ppm (mg\/L); 0.001 ppt (g\/L); 0.01 ppt (g\/L); 0.1 ppt (g\/L); 1 ppt (g\/L), Automatic: 1 ppm (mg\/L) from 0 to 9999 ppm (mg\/L); 0.01 ppt (g\/L) from 10.00 to 99.99 ppt (g\/L); 0.1 ppt (g\/L) from 100.0 to 400.0 ppt (g\/L), Automatic ppt (g\/L): 0.001 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1% of reading or ±1 ppm (mg\/L), whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 70.00 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 PSU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% of reading or ±0.01 PSU whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (PSU) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 σt, σ₀, σ₁₅\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSalinity (Seawater Sigma) Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity or salinity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Range\u003c\/td\u003e\n\u003ctd\u003e0 to 999999 Ω cm; 0 to 1000.0 kΩ cm; 0 to 1.0000 MΩ cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Resolution\u003c\/td\u003e\n\u003ctd\u003edependent on resistivity reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eResistivity Calibration\u003c\/td\u003e\n\u003ctd\u003ebased on conductivity calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 500.0%; 0.00 to 50.00 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1%; 0.01 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e0.0 to 300.0% saturation: ±1.5% of reading or ±1.0% saturation whichever is greater, 0.00 to 30.00 ppm (mg\/L): ±1.5% of reading or ±0.10 ppm (mg\/L), whichever is greater, 30.00 ppm (mg\/L) to 50.00 ppm (mg\/L): ±3% of reading, 300.0 to 500.0% saturation: ±3\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic one or two points at 0 and 100% or one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 99.9 FNU; 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 FNU from 0.0 to 99.9 FNU 1 FNU from 100 to 1000 FNU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 FNU or ±2 % of reading, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTurbidity Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic 1, 2, or, 3 points at 0, 20 and 200 FNU, or custom\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Range\u003c\/td\u003e\n\u003ctd\u003e-5.00 to 55.00 °C, 23.00 to 131.00 °F, 268.15 to 328.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 K, 0.01 °C, 0.01 °F\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.15 °C; ±0.27 °F; ±0.15 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Calibration\u003c\/td\u003e\n\u003ctd\u003eautomatic at one custom point\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from -5 to 55 °C (23 to 131 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Range\u003c\/td\u003e\n\u003ctd\u003e0.02 to 200 ppm as NH\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e+\u003c\/sup\u003e-N\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 % reading or 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonium Calibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0.6 to 200.0 ppm Cl (as Cl- )\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm 0.1 ppm to 200.0 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 % of reading or 2 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Calibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.62 to 200.0 ppm Ni (as NO3 – -N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm to 1 ppm 0.1 ppm to 200 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Calibration\u003c\/td\u003e\n\u003ctd\u003e1 or 2 point, 10 ppm and 100 ppm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e44,000 records (continuous logging or log-on-demand of all parameters)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Interval\u003c\/td\u003e\n\u003ctd\u003eone second to three hours\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB (with HI 929829 software)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e1.2V (4) NiMH, rechargeable batteries, size C type; up to 140 hours depending on configuration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Protection\u003c\/td\u003e\n\u003ctd\u003eIP67\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50°C (32 to 122°F); RH max 100%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e221 x 115 x 55 mm (8.7 x 4.5 x 2.2”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e750 g (26.5 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGPS\u003c\/td\u003e\n\u003ctd\u003e12 channel receiver 10 m (30 ft) accuracy\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003e\u003c\/h3\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cp\u003eThe HI9829 and HI98290 (GPS model) are supplied with a HI710140 hard carrying case, HI7612VDC adapter, HI7698292 probe maintenance kit, HI929829 PC application software, HI7698291 USB cable (PC to meter), HI710045 power supply cable, HI710046 cigarette lighter power cable, HI9829-25 quick calibration solution, HI920005 iButton with holder (5), HI7609829-1 pH\/ORP sensor, HI7609829-2 galvanic DO sensor, HI7609829-3 EC sensor, HI7698290 short calibration beaker, HI7698295 short protective weighted shield, NiMH rechargeable “C” cell batteries (4), 12VDC power adapter, and instruction manual. *CALibration beaker and HI7698296 long protective weighted shield in place of the EC sensor, short calibration beaker and short protective shield. Probes selected with turbidity option will also include turbidity calibration solutions (230 ml); HI9829-16 0 FNU, HI769829-17 20 FNU, and HI9829-18 200 FNU.\u003c\/p\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI9829-01-web\" target=\"_blank\"\u003eHI9829 Multiparameter pH\/ISE\/EC\/DO\/Turbidity Waterproof Meter with GPS option\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871462130033,"sku":"HI9829-02","price":246292.65,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi9829-ec-probe.jpg?v=1792646989","url":"https:\/\/hannainst.in\/products\/multiparameter-ph-ise-ec-do-turbidity-waterproof-meter-with-gps-option-hi9829","provider":"hanna","version":"1.0","type":"link"}