{"product_id":"orp-mini-controller-with-analog-output-bl932700-115-230vac","title":"ORP Mini Controller with Analog Output - BL932700-115\/230VAC","description":"\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL932700_angle.jpg\" alt=\"BL932700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAdjustable Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL932700 features a dosing relay which may be configured to dose above or below a user programmable mV setpoint.\u003c\/p\u003e\n\u003ch4\u003eSelectable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eThe mini controller may be programmed to deactivate a valve,  pump,  or connected device if its activation continues over a selected time; adjustable from 5 to 30 minutes.\u003c\/p\u003e\n\u003ch4\u003eSelectable Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch,  normal “Auto” operation may be overridden turning your connected device “Off” from operation or always “On.”\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL932700_rear.jpg\" alt=\"BL932700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eAnalog Output Communication\u003c\/h4\u003e\n\u003cp\u003eThe BL932700 features a 4 - 20 mA analog output for connection to a data logger,  chart recorder,  or other device.\u003c\/p\u003e\n\u003ch4\u003eExternal Disabling Feature\u003c\/h4\u003e\n\u003cp\u003eA normally open contact may connect to a level controller or flow monitor. This safety feature may be used to prevent continuous dosing in the event of specific or undesired system conditions.\u003c\/p\u003e\n\u003ch4\u003eMatching Pin Connection\u003c\/h4\u003e\n\u003cp\u003eAn included matching pin option helps protect the sensor from ground loop effects that may lead to erratic readings or system damage.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-2.jpg\" alt=\"BL931700\" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eFront View\u003c\/h4\u003e\n\u003cp\u003eInstallation cut-out dimensions are provided as well as outside panel dimensions.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL-1.jpg\" alt=\"BL931700\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSide View\u003c\/h4\u003e\n\u003cp\u003eAdjustable location brackets allow the controller to slide easily and securely into place..\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e BL932700-1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e ORP Mini Controller with Analog Output - BL932700-115\/230VAC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Range\u003c\/td\u003e\n\u003ctd\u003e ±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Resolution\u003c\/td\u003e\n\u003ctd\u003e 1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±5 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Calibration\u003c\/td\u003e\n\u003ctd\u003e manual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Relay\u003c\/td\u003e\n\u003ctd\u003e  maximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003emV (ORP) Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003e adjustable from -1000 to 1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable from -1000 to 1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Terminals\u003c\/td\u003e\n\u003ctd\u003e reducing or oxidizing, selectable on the back panel \u003cbr\u003econtact open=reductant dosage=relay ON if measurement \u0026gt; setpoint \u003cbr\u003econtact closed=oxidant dosage=relay ON if measurement \u0026lt; setpoint\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003e adjustable, typically from 5 to approximately 30 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003e 4 to 20 mA, accuracy ±0.20 mA, 500 Ω maximum load\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e  BL932700-0: 12 VDC adapter (included); \u003cbr\u003eBL932700-1: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e BL932700-0: 200 g (7.1 oz.)\u003cbr\u003eBL932700-1: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eBL932700-0 (12 VDC) and BL932700-1 ( 115\/230V) are supplied with mounting brackets, transparent cover and instruction manual.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/BL932700-1\"\u003eORP Mini Controller with Analog Output - BL932700-115\/230VAC\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871162728817,"sku":"BL932700-1","price":30117.0,"currency_code":"INR","in_stock":true}],"url":"https:\/\/hannainst.in\/products\/orp-mini-controller-with-analog-output-bl932700-115-230vac","provider":"hanna","version":"1.0","type":"link"}