{"product_id":"ph-and-ec-tds-and-do-starter-benchtop-meter-hi2600","title":"pH and EC\/TDS and DO Starter Benchtop Meter - HI2600","description":"\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003cthead style=\"color: #292f36;\"\u003e\n\u003ctr\u003e\n\u003cth style=\"font-weight: bold;\"\u003eSpecification\u003c\/th\u003e\n\u003cth style=\"font-weight: bold;\"\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eusing pH electrode HI11310\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−2.00 to 16.00 pH\n−2.000 to 16.000 pH *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 pH\n0.001 pH *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.01 pH\n±0.002 pH *\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003emV Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C **\n(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C; (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI11310)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C; (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003epH calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, up to three (five*)\npoints Option to select from five (seven*) standard buffers: pH 1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45* and two custom buffers*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600 - using ORP electrode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI36180\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e± 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eORP Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV (±999.9 mV)\n±1 mV (±2000 mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C**(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI36180)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eCalibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic, using integral temperature sensor\n−5.0 to 100.0 °C (23.0 to 212.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* records organized in:\n• Manual log-on-demand, maximum 200 logs\n• Manual log-on-stability, maximum 200 logs\n• Interval logging*\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600 - using the four-ring conductivity probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI763100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 29.99 μS\/cm\n30.0 to 299.9 μS\/cm\n300 to 2999 μS\/cm\n3.00 to 29.99 mS\/cm\n30.0 to 200.0 mS\/cm\nup to 500.0 mS\/cm absolute conductivity***\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 μS\/cm\n0.1 μS\/cm 1 μS\/cm\n0.01 mS\/cm 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\n(±0.05 μS\/cm or 1 digit,whichever is greater)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 14.99 ppm (mg\/L)\n15.0 to 149.9 ppm (mg\/L)150 to 1499 ppm (mg\/L)\n1.50 to 14.99 g\/L\n15.0 to 100.0 g\/L\nup to 400.0 g\/L absoluteTDS ‡ (with 0.80 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm\n0.1 ppm\n1 ppm 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading (±0.03 ppm or 1 digit, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity* Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 400.0 % NaCl\n2.00 to 42.00 PSU\n0.00 to 80.00 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity* Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1% NaCl\n0.01 PSU\n0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eSalinity* Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range (HI763100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20.0 to 120.0 °C**(−4.0 to 248.0 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution (HI763100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C (0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F (HI763100)\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C (0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEC calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eCell factor calibration\nSix standards available: 84 µS\/cm, 1413 μS\/cm 5.00 mS\/cm, 12.88 mS\/cm, 80.0 mS\/cm, 111.8 mS\/cm\nOne point offset: 0.00 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003e\"Salinity calibration* (% NaCl only)\"\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point with HI7037 standard\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e• Automatic, −5 to 100 °C (23 to 212 °F)\n• NoTC, can be selected to measure absolute conductivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eConductivity temperature coefficient*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 6.00 %\/°C (EC and TDS only)\n(1.90 %\/°C default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTDS factor*\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.40 to 0.80 (0.50 default)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000* (400) records organized in:\n• Manual log-on-demand, maximum 200 logs\n• Manual log-on-stability, maximum 200 logs\n• Interval logging*, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e* When operating in Standard Mode only!\n‡ Absolute conductivity (TDS) is the conductivity value without temperature compensation.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eHI2600 - using the Dissolved Oxygen probe\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eHI764080\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.00 to 45.00 ppm (mg\/L)\n0.0 to 300.0%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.01 ppm (mg\/L)\n0.1%\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±1.5% of reading ±1 digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e-20.0 to 120.0 °C * (−4.0 to 24\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 °C\n(0.1 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature Accuracy at 25 °C \/ 77 °F\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.5 °C\n(0.9 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eOne or two points at 0% (HI7040) and 100% (water-saturated air)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Pressure compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eAutomatic\n450.0 to 850.0 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Pressure compensation resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mmHg\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Salinity compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 40 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDO Salinity compensation resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eTemperature compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.0 to 50.0 °C (32.0 to 122 °F)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eLogging\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 1000 records organized in:\n• Manual log-on-demand, maximum 200 logs\n• Manual log-on-stability, maximum 200 logs\n• Interval logging**, maximum 600 logs (100 lots)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eNotes\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e* Temperature limits will be reduced to actual probe limits.\n** When operating in Standard Mode only!\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePC interface\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003ePower supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUSB Type C (5 VDC; 500 mA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0 to 50 °C (32 to 122 °F)\nMaximum 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 inches)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 0.85 kg (1.87 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/www.documentation.hannainst.com\/manuals\/HI2600\"\u003epH and EC\/TDS and DO Starter Benchtop Meter - HI2600\u003c\/a\u003e\u003c\/p\u003e\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003ctable style=\"color: #000000;\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI2600-01 pH, EC, and DO Benchtop Meter (115V)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI11310 pH digital electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI764026 electrode holder with the following accessories:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- base plate with integrated pivot pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- cable holder clip, attache\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• pH calibration kit:\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 4 buffer solution (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 7 buffer solution (4 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e- pH 10 buffer solution sachets (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Electrode cleaning solution (2 sachets)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• HI920018 1.5 m USB-C to USB-C cable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• USB-C power adapter\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Instrument quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Probe \/ electrode quality certificate\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e• Battery safety insert\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461376369,"sku":"HI2600","price":66656.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI2600_Right-2__45600.jpg?v=1792646978","url":"https:\/\/hannainst.in\/products\/ph-and-ec-tds-and-do-starter-benchtop-meter-hi2600","provider":"hanna","version":"1.0","type":"link"}