pH and ORP Benchtop Meter Options
HI2620 Features
-
pH Resolution: 0.01 pH
-
Calibration Points: Up to 3
-
Data Logging: No
-
PC/USB Data Export: No
-
Standard Mode (Full Features): No
HI2621 Features
-
pH Resolution: 0.01 / 0.001 pH
-
Calibration Points: Up to 5
-
Data Logging: Yes – up to 1000 logs
-
PC/USB Data Export: Yes
-
Standard Mode (Full Features): Yes
The Benchtop Meter for Every Lab Setting

With a color LCD display, capacitive touch keypad, and clear on-screen text guides, users can easily set up, calibrate, and measure quickly.
Our Simple Benchtop Meters are designed for both experienced professionals and those who prefer a straightforward, streamlined workflow.
Digital Smart Electrodes for Enhanced Measurements

Our Simple Benchtop Meters (HI2620 and HI2621) measure pH and ORP with the supplied HI11310 Digital Smart pH Electrode.
Advantages of the pH Digital Electrode
- Designed for various industries and applications, this probe is durable and suitable for use in chemical analysis.
- Collect stable readings even in electrically noisy environments and eliminate drift with automatic noise filtering and digital processing.
- The built-in temperature sensor ensures optimal temperature compensation. There is no need to manage an additional temperature probe.
- Change electrodes easily without recalibrating. All data from the last calibration is stored in the electrode for faster setup and less maintenance when switching electrodes.
- Gain traceability with automatic sensor recognition and a unique serial ID number for each Digital Electrode.
- Be proactive and know the health of your pH electrode with Sensor Check™. Predictive maintenance alerts notify you when to clean, recalibrate, or replace your pH electrode before it fails.
- Equipped with a modern 3.5 mm connector that is sealed to protect against moisture and corrosion.
Compatible Electrodes
HI10430
Digital glass body pH electrode for hydrocarbons and solvents.
HI10530
Digital glass body pH electrode for semi-solids and emulsions.
HI11310
Digital glass body pH electrode for general-purpose applications.
HI12300
Digital PEI body pH electrode for field applications.
HI12301
Digital PEI body pH electrode with matching pin for field applications.
HI36180
Digital glass body ORP electrode for general-purpose applications.

What's Included
- HI11310 pH Digital Electrode
- pH calibration kit:
- pH 4 buffer solution – 2 sachets
- pH 7 buffer solution – 4 sachets
- pH 10 buffer solution – 2 sachets
- Electrode cleaning solution – 2 sachets
- HI764026 electrode holder with accessories
- HI920018 1.5 m USB-C to USB-C cable
- USB-C power adapter
- Instrument quality certificate
- Electrode quality certificate
- Battery safety insert
- Quick reference guide with QR code for instruction manual download
Specifications
| Models |
HI2620 and HI2621 using pH electrode HI11310 |
| pH Range |
−2.00 to 16.00 pH −2.000 to 16.000 pH* |
| pH Resolution |
0.01 pH 0.001 pH* |
| pH Accuracy at 25 °C / 77 °F |
±0.01 pH ±0.002 pH* |
| mV Range |
±1000.0 mV |
| mV Resolution |
0.1 mV |
| mV Accuracy at 25 °C / 77 °F |
±0.2 mV |
| Temperature Range – HI11310 |
−20.0 to 120.0 °C** −4.0 to 248.0 °F |
| Temperature Resolution – HI11310 |
0.1 °C 0.1 °F |
| Temperature Accuracy at 25 °C / 77 °F – HI11310 |
±0.5 °C ±0.9 °F |
| pH Calibration |
Automatic, up to three (five*) points.
Option to select from standard buffers: pH 1.68*, 4.01 or 3.00, 6.86, 7.01, 9.18, 10.01, 12.45* and two custom buffers* |
| ORP Electrode |
HI36180 |
| ORP Range |
±2000.0 mV |
| ORP Resolution |
0.1 mV |
| ORP Accuracy at 25 °C / 77 °F |
±0.2 mV (±999.9 mV) ±1 mV (±2000 mV) |
| Temperature Range – HI36180 |
−20.0 to 120.0 °C** −4.0 to 248.0 °F |
| Temperature Resolution – HI36180 |
0.1 °C 0.1 °F |
| Temperature Accuracy at 25 °C / 77 °F – HI36180 |
±0.5 °C ±0.9 °F |
| ORP Calibration |
Single point offset |
| Temperature Compensation |
Automatic, using integral temperature sensor −5.0 to 100.0 °C (23.0 to 212.0 °F) |
| Logging – HI2621 Only |
Up to 1000* records organized in:
Manual log-on-demand – maximum 200 logs Manual log-on-stability – maximum 200 logs Interval logging* |
| PC Interface – HI2621 Only |
USB-C |
| Power Supply |
USB Type-C 5 VDC; 500 mA |
| Environment |
0 to 50 °C (32 to 122 °F) Maximum 95% RH non-condensing |
| Dimensions |
205 × 160 × 77 mm (8.0 × 6.2 × 3.0 inches) |
| Weight |
Approximately 0.85 kg (1.87 lbs.) |
* When operating in Standard Mode in HI2621 only.
** Temperature limits will be reduced to actual probe limits.
pH and ORP Starter Benchtop Meter – HI2620 and HI2621
The HI2620 and HI2621 provide fast and accurate pH and ORP measurements using Hanna Instruments digital smart electrodes. Automatic sensor recognition, integrated temperature measurement, calibration capabilities and a simple user interface make these meters suitable for routine laboratory measurements.
The HI2621 additionally provides data logging, Standard Mode and USB-C data transfer, making it suitable for applications requiring stored and transferable measurement records.
Download Product manual