{"product_id":"ph-electrode-with-built-in-temperature-sensor-and-din-connector-hi1610d","title":"pH Electrode with Built-In Temperature Sensor and DIN Connector - HI1610D","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH,  bulb shape,  body material,  type of junction,  type of reference and electrolyte used are just some of the design considerations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe HI1610D uses general purpose (GP) glass,  spherical bulb,  glass body,  single ceramic junction and is refillable with 3.5M KCl + AgCl.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1610_glass.png\" alt=\"Glass\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGeneral Purpose Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eThe measurement of pH at very high temperatures is detrimental to the sensitive glass bulb and will shorten the life of it. A pH electrode with general purpose (GP) glass will have a resistance of 100 megaohms at 25℃ while the resistance of LT glass is around 50 megaohms at 25℃. As the temperature of the glass decreases in the sample,  the resistance of the LT glass will approach that of GP glass. If using GP glass,  the resistance would increase above the optimum range,  resulting in increased impedance and ultimately affecting the measurement. The HI1610D is suitable to use with samples that measure from 0 to 70℃.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1610_tip.png\" alt=\"Flat Tip\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eSpherical Bulb\u003c\/h4\u003e\n\u003cp\u003eThe spherical bulb is for general purpose use. Other tip shapes include conic for penetration and flat tip for surface measurements.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1610_glassBody.png\" alt=\"glass Body\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGlass Body\u003c\/h4\u003e\n\u003cp\u003eThe glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium,  the steadier the reference potential.\u003c\/p\u003e\n\u003ch5\u003eSingle Ceramic Junction\u003c\/h5\u003e\n\u003cp\u003eThe outer junction of an electrode,  also known as a salt bridge,  is necessary component of the electrical circuit. The movement of ions must flow through the junction for a steady reading. The outer reference has a single ceramic frit. The ceramic is a porous material that is easily fused with the glass body and has a similar expansion coefficient. A single ceramic junction has a flow rate of 15-20 μL\/hour. Other junction types are available with higher flow rates and made with different materials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI5312_Refillable.png\" alt=\"Refillable\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eRefillable\u003c\/h4\u003e\n\u003cp\u003eThe HI1610D is a refillable probe. Since it is a single junction pH electrode the fill solution is the HI7071 3.5M KCl + AgCl. If using a refillable pH electrode,  the fill cap should be removed prior to calibration and measurement. Removing the cap creates positive head pressure in the reference cell allowing for higher flow rate of electrolyte through the outer junction. A higher flow rate will result in a faster and more stable reading.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/FC214D_DinConnector.png\" alt=\"DIN connector\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eDIN Connector\u003c\/h4\u003e\n\u003cp\u003eThe HI1610D uses a DIN connector. This type of connector is generally proprietary to the meters they are supplied with and may not be interchangeable. The HI1610D is recommended for use with Hanna's HI8314 pH meter. Other type of connectors include BNC,  screw type,  T-type,  and 3.5mm to name a few.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI1610D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH Electrode with Built-In Temperature Sensor and DIN Connector - HI1610D\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e pH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e single, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e ceramic, single \/ 15-20 µL\/h\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRefill Electrolyte\u003c\/td\u003e\n\u003ctd\u003e 3.5M KCl + AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e spheric (dia: 9.5 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 70°C (32 to 158°F) - GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 175.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 12 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e 5-pole; 1 m (3.3 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e DIN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e yes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e laboratory general purpose\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI1610D\"\u003epH Electrode with Built-In Temperature Sensor and DIN Connector - HI1610D\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871233638769,"sku":"HI1610D","price":17175.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1610.jpg?v=1792645910","url":"https:\/\/hannainst.in\/products\/ph-electrode-with-built-in-temperature-sensor-and-din-connector-hi1610d","provider":"hanna","version":"1.0","type":"link"}