{"product_id":"ph-electrode-with-micro-bulb-and-bnc-pin-connector-hi1083p","title":"pH Electrode with Micro Bulb and BNC + Pin Connector  - HI1083P","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHanna Instruments offers a wide variety of pH electrodes that are designed for many different applications. The type of glass used for sensing pH,  bulb shape,  body material,  type of junction,  type of reference and electrolyte used are just some of the design considerations.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eThe HI1083P uses general purpose (GP) glass,  micro bulb,  glass body,  and open junction with viscolene gel electrolyte.\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(240px, 1fr)); gap: 32px 24px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1083BGPGlassFormulation.png\" alt=\"Glass\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGeneral Purpose Glass Formulation\u003c\/h4\u003e\n\u003cp\u003eGeneral Purpose (GP) glass,  as the name implies,  is a standard glass formulation that is used for general use. A pH electrode with GP glass will have a resistance of 100 megaohms at 25℃ and is suited for measuring pH of samples that are at ambient temperatures. The HI1083P is suitable to use with samples that measure from 0 to 50℃.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1083B_MicroBulbTip.png\" alt=\"Micro Bulb\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eMicro Bulb Tip\u003c\/h4\u003e\n\u003cp\u003eThe 3 mm micro bulb tip design allows for measurement of pH in samples with very little volume or space. The HI1083P can be used in samples with volumes as little as 100 µL. It is an ideal probe for measuring the pH in 96 well plates.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-direction: column; align-items: stretch; text-align: left;\"\u003e\n\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1083BGlassBody.png\" alt=\"Glass Body\" loading=\"lazy\" style=\"display: block; width: auto; max-width: 100%; max-height: 220px; height: auto; margin: 0 auto 16px; object-fit: contain;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGlass Body\u003c\/h4\u003e\n\u003cp\u003eThe glass body is ideal for laboratory use. The glass is resistant to many harsh chemicals and is easily cleaned. The glass body also allows for a fast transfer of heat to the internal reference electrolyte. The mV generated by the reference cell is temperature dependent. The faster the electrode reaches equilibrium,  the steadier the reference potential.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1083BOpenJunctionRef.png\" alt=\"Open Junction\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eOpen Junction Reference\u003c\/h5\u003e\n\u003cp\u003eSuspended solids and proteins found in food products will clog a conventional ceramic reference junction. This clogging will impede the measurement circuit between the indicating electrode and the internal reference resulting in slower response time,  erratic readings,  and frequent electrode replacement. The open junction design consists of a solid gel interface (viscolene) between the sample and internal Ag\/AgCl reference. This interface not only prevents silver from entering the sample,  but also makes it impermeable to clogging,  resulting in a fast response and stable readings.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI1043D_DinplusPin.png\" alt=\"BNC pin connector\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eBNC + Pin Connector\u003c\/h5\u003e\n\u003cp\u003eThe HI1053P has a BNC and pin connector. The BNC connector is universal in that it can be used on any pH meter that has the female BNC probe input. The pin connector is used to enable the CAL Check function on the following benchtop pH meters; HI122,  HI123,  HI221,  HI222,  HI223,  HI2221,  HI2222,  and HI2223.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI1083P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH Electrode with Micro Bulb and BNC + Pin Connector  - HI1083P\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMeasurement Range\u003c\/td\u003e\n\u003ctd\u003e pH: 0 to 13\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eReference Cell Type\u003c\/td\u003e\n\u003ctd\u003e single, Ag\/AgCl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eJunction Type\/Flow Rate\u003c\/td\u003e\n\u003ctd\u003e open\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eType of Electrolyte\u003c\/td\u003e\n\u003ctd\u003e viscolene\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Material\u003c\/td\u003e\n\u003ctd\u003e glass\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTip \/ Shape\u003c\/td\u003e\n\u003ctd\u003e spheric (dia: 3 mm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMatching Pin\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMax. Pressure\u003c\/td\u003e\n\u003ctd\u003e 0.1 bar\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Operating Range\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F) - GP\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBody Length\/Overall Length\u003c\/td\u003e\n\u003ctd\u003e 120 mm \/ 163.5 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTemperature Sensor\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOuter Diameter\u003c\/td\u003e\n\u003ctd\u003e 3 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCable\u003c\/td\u003e\n\u003ctd\u003e coaxial; 1 m (3.3’)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnector Type\u003c\/td\u003e\n\u003ctd\u003e BNC + pin\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmplifier\u003c\/td\u003e\n\u003ctd\u003e no\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eRecommended Use\u003c\/td\u003e\n\u003ctd\u003e NMR tubes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI1083P\"\u003epH Electrode with Micro Bulb and BNC + Pin Connector - HI1083P\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871197856113,"sku":"HI1083P","price":44228.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi1083b_3.jpg?v=1792645865","url":"https:\/\/hannainst.in\/products\/ph-electrode-with-micro-bulb-and-bnc-pin-connector-hi1083p","provider":"hanna","version":"1.0","type":"link"}