{"product_id":"ph-orp-ise-conductivity-dissolved-oxygen-kit-hi6553p-02","title":"pH\/ORP\/ISE, Conductivity, Dissolved Oxygen Kit - HI6553P-02","description":"\u003cp\u003eHI6553P-02 (EU power plug) is supplied with HI6000 housing unit; one HI6000-2 pH\/ORP\/ISE hardware module (installed); HI6000-3 EC hardware module (installed); HI6000-4 DO hardware module (installed); HI1131B pH electrode; HI7662-TW temperature probe; HI7631233 EC \u0026amp; resistivity probe; HI764833 polarographic DO probe; pH 4.01 buffer solution, 2 sachets; pH 7.01 buffer solution, 2 sachets; pH 10.01 buffer solution, 2 sachets; electrode cleaning solution, 2 sachets; pH \u0026amp; ORP electrode storage solution (25 mL); 3.5M KCl electrolyte solution (30 mL); DO electrolyte solution (30 mL); capillary pipette, 1 piece; 1413 μS\/cm standard solution, 2 sachets; 5000 μS\/cm standard solution, 2 sachets; 12880 μS\/cm standard solution, 2 sachets; electrode rinse solution, 2 sachets; pH electrode cap; membrane cap and O-ring, 2 pieces; electrode holder with base plate, screw, cable holder clip (requires mounting), adapter (attached); 24 VDC power adapter; USB-C to USB-A cable; meter quick reference guide; hardware modules quick reference guides and quality certificates; probes and meter quality certificates.\u003c\/p\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable width=\"1229\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSpecification Name\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e\u003cstrong\u003eDetail\u003c\/strong\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSku\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eHI6553P-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e-2.0 to 20.0 pH; -2.00 to 20.00 pH; – 2.000 to 20.000 Ph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 pH; 0.01 pH; 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003epH Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±0.1 pH; ±0.01 pH; ±0.002 pH (±1 last significant digit)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCalibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCalibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Semiautomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eStandard Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eHanna and NIST (pH 1.68, 3.00, 4.01, 6.86, 7.01, 9.18, 10.01, 12.45)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCustom Buffers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCustom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eOption to select from eight standard buffers and user-defined custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eFirst Calibration Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eOffset or Point (user setting)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eIsopotential Point\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e-2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e-2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1 mV; 0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±0.2 mV ±1 last significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003emV Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSingle point offset, ±2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1.0×10\u003csup\u003e¯5\u003c\/sup\u003e to 300.0 ppt (g\/L or mg\/mL)\n5.0×10\u003csup\u003e¯3\u003c\/sup\u003e to 1.0×10\u003csup\u003e5\u003c\/sup\u003e ppm (mg\/L or µg\/mL)\n1.0 to 5.0×10\u003csup\u003e7\u003c\/sup\u003e ppb (µg\/L)\n1.0×10\u003csup\u003e¯7\u003c\/sup\u003e to 10.0 M (mol\/L)\n1.0×10\u003csup\u003e¯4\u003c\/sup\u003e to 1.0×10\u003csup\u003e4\u003c\/sup\u003e mmol\/L\n1.0×10\u003csup\u003e¯6\u003c\/sup\u003e to 60.0 %w\/v\n5.0×10\u003csup\u003e¯7\u003c\/sup\u003e to 5.0×10\u003csup\u003e7\u003c\/sup\u003e user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1, 2, 3 significant digits\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±0.5% (monovalent ions); ±1% (divalent ions)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAll Standards; Standard Group\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e7 standard solutions available for each concentration unit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Custom Standards\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eISE Custom Group\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.000 to 9.999 μS\/cm; 10.00 to 99.99 μS\/cm; 100.0 to 999.9 μS\/cm; 1.000 to 9.999 mS\/cm; 10.00 to 99.99 mS\/cm; 100.0 to 1000.0 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.001 μS\/cm; 0.01 μS\/cm; 0.1 μS\/cm; 0.001 mS\/cm; 0.01 mS\/cm; 0.1 mS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading or ±0.010 μS\/cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Cell Constant\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.0500 to 200.0000 \/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSingle; Up to 5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConductivity Calibration Solutions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e84 μS\/cm; 1413 μS\/cm; 5000 μS\/cm; 12880 μS\/cm; 80000 μS\/cm; 111800 μS\/cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eResistivity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1.0 to 99.9 Ω•cm; 100 to 999 Ω•cm; 1.00 to 9.99 KΩ•cm; 10.0 to 99.9 KΩ•cm; 100 to 999 KΩ•cm; 1.00 to 9.99 MΩ•cm; 10.0 to 100.0 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eResistivity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 Ω•cm; 1 Ω•cm; 0.01 KΩ•cm; 0.1 KΩ•cm; 1 KΩ•cm; 0.01 MΩ•cm; 0.1 MΩ•cm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eResistivity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading or ±1 Ω•cm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTotal Dissolved Solids (TDS) Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading or ±0.01 ppm, whichever is greater\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.00 to 42.00 PSU (Practical Salinity Scale); 0.00 to 80.00 ppt (Natural Sea Water); 0.0 to 400.0 % (Percent Scale)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.01 PSU; 0.01 ppt; 0.1 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±1 % of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1 point, using 100 % salinity calibration solution (% scale only)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSalinity Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eManual\n\u0026gt; 0.00 to 45.00 PSU or ppt\n\u0026gt; 0.0 to 130.0 %\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Range (\u003cspan style=\"color: #4d4d4d;\"\u003eHI764833 polarographic DO probe)\u003c\/span\u003e\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.0 to 300.0 % saturation; 0.00 to 45.00 mg\/L (ppm) concentration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 % saturation; 0.01 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eRefer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Calibration Points\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eOne or two points at 100.0 % (8.26 mg\/L) and 0.0 % (0.00 mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDO Calibration Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Manual (user entered value in % saturation, mg\/L, or ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e450.0 to 850.0 mmHg; 600.0 to 1133.2 mbar; 60.00 to 113.32 kPa; 17.72 to 33.46 inHg; 8.702 to 16.436 psi; 0.5921 to 1.1184 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 mmHg; 0.1 mBar; 0.01 kPa; 0.01 inHg; 0.001 psi; 0.0001 atm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e±3 mmHg within ±15 % from calibration point; ±3 mmHg ±1 least significant digit\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBarometric Pressure Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic (meter-integrated barometer); Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e−20.0 to 120.0 °C; −4.0 to 248.0 °F; 253.2 to 393.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0.1 °C; 0.1 °F; 0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor pH and conductivity: ±0.2 °C; ±0.4 °F; ±0.2 K\nFor DO: Refer to probe used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSingle point, adjustable\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Compensation\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor pH and DO: Automatic; Manual\nFor Conductivity: Linear; Natural; Standard; Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReference Temperature\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor Conductivity: 5.0 to 30.0 °C (41.0 to 86.0 °F , 278.2 to 303.2 K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTemperature Coefficient\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFor Conductivity: 0.00 to 10.00 %\/°C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReading Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eDirect\nDirect\/Autohold\nFor ISE Only: Known Addition, Known Subtraction, Analyte Addition, Analyte Subtraction\nFor Conductivity: Direct\/USP\nFor DO Only: OUR, SOUR, BOD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eBasic View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eMeasurement data; Measurement profile (if enabled); Stability status\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eSimple GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eBasic view information\nFor pH: Last calibration date, slope, offset (pH, Rel. mV – ISE only)\nFor Conductivity: Last calibration date and offset\nFor DO: Last calibration date, offset, average slope\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eFull GLP View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eSimple GLP Information; Calibration point details (pH, ISE, conductivity, salinity, and DO)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eGraph View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eBasic view information; Measurement versus time graph\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eTable View\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eBasic view information; Table with measurements updated every second\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReading Stability Criteria\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAccurate; Medium; Fast\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eReading Sampling Rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1000 ms\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eAutomatic; Manual; Autohold\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Number of Records\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e50,000 maximum per file and stores at least 1,000,000 data points per user\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Automatic Interval\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1, 2, 5, 10, 30 seconds and 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Sample ID\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eIncremental Mode; Manual\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eLogging Export Option\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e.CSV file format\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity USB-A\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e2 ports\nkeyboard and\/or printer input\nUSB Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity USB-C\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e1 port\nPC Connectivity and USB-C Type Flash Drive\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity Wi-Fi \u0026amp; Ethernet\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eFTP; Web Server (Log transfer and download); Email\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eConnectivity RS232\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eConnecting peripherals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eCalibration Reminder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eDaily (0 minutes to 23 hours and 59 minutes); Periodic (1 minute to 30 Days, 23 hours and 59 minutes); or Disabled\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eUsers\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eUp to 9 users and the default administrator account\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003eDC adapter 100-240 VAC to 24 VDC 2A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eEnvironment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e0 to 50 °C \/ 32 to 122 °F \/ 273 to 323 K maximum 95 % RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd width=\"132\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd width=\"1097\"\u003e8.05 lbs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871460884849,"sku":"HI6553P-02","price":195264.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI6553-White__49705-1.jpg?v=1792646970","url":"https:\/\/hannainst.in\/products\/ph-orp-ise-conductivity-dissolved-oxygen-kit-hi6553p-02","provider":"hanna","version":"1.0","type":"link"}