{"product_id":"ph-transmitter-with-4-20-ma-galvanically-isolated-output-hi8614-with-lcd","title":"pH Transmitter with 4-20 mA Galvanically Isolated Output - HI8614-With LCD - HI8614LN","description":"\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI8614L_n.jpg\" alt=\"HI8614 pH Transmitter \" width=\"1200\" height=\"1200\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch5 style=\"margin-top: 0;\"\u003eTwo-Wire pH Transmitters\u003c\/h5\u003e\n\u003cp\u003eHI 8614 is 2-wire water-resistant transmitter specially designed for long distance measurement of pH in industrial applications.\u003c\/p\u003e\n\u003cp\u003eTwo-wire transmitters are widely used for process control in industry. These instruments are particularly useful in industrial conditions where electrical interference is an important factor\u003c\/p\u003e\n\u003cp\u003eBy galvanically isolating the signals,  any interference created is prevented from reaching the transmitter. Industrial environments are often associated with corrosive conditions,  therefore any instrumentation used must be resistant to liquids and corrosion. Hanna transmitters meet all of these criteria and they only use two wires which reduces costs and eliminates the need for an expensive coaxial cable. Two-wire transmitters are ideal when used in remote applications that do not have AC power available.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eHI8614 pH Transmitter FEATURES\/BENEFITS:\u003c\/h4\u003e\n\u003ch5\u003eAutomatic Temperature Compensation (ATC)\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eTemperature compensation is performed by the transmitter’s ATC (Automatic Temperature Compensation) circuitry when measurements are taken with a temperature probe attached; if ATC is not required,  it is also possible to substitute a fixed resistor for the temperature probe.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eIP Protection\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe unit is enclosed in a protective casing conforming to IP 65 standards.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eFlexible for Your Needs\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe transmitter can be connected to any Hanna controller that accepts analog input.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEasy Calibration\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eCalibration is performed by the adjustment of two independent trimmers — slope and offset.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eBNC Connector\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe transmitters use a universal BNC socket for quick and secure connection to any electrode with a BNC connector.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eIsolated Input\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eThe input is isolated from the current loop to eliminate problems related to ground loop,  low insulation cables,  multiple electrode connections,  and a common mode voltage of up to 100V ensures true differential readings\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eVersion with LCD\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI8614”L” versions allow easy verification and monitoring of measured values and is easier to calibrate and maintain.\u003c\/li\u003e\u003c\/ul\u003e\n\u003ch5\u003eEasy Installation\u003c\/h5\u003e\n\u003cul\u003e\u003cli\u003eHI8614 is very easy to install,  wall mounted transmitter. It is supplied with 4 mounting screws\u003c\/li\u003e\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003e HI8614LN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003e pH Transmitter with 4-20 mA Galvanically Isolated Output - HI8614-With LCD\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003e 0.00 to 14.00 pH; 4–20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003e  (for “L” models) 0.01 pH; 0.01 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003e ±0.02 pH; ±0.02 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003e offset: ±2 pH; ±2.2 mA; slope: 86 to 116%; ±0.5 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003e fixed or automatic from 0 to 100°C (32 to 212°F) with HI76608 probe\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Input impedence\u003c\/td\u003e\n\u003ctd\u003e 1012 Ohm \u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e 4-20 mA (isolated)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003e pH electrode with BNC connector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e LCD only for HI8614LN\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e HI8614N: 18-30 VDC; HI8614LN: 20-36 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e 0 to 50°C (32 to 122°F); RH max 95% non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003e IP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e 165 x 110 x 71 mm (6.5 x 4.3 x 2.8”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e 1 kg (2.2 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\u003cp\u003eHI8614N and HI8614LN (with display) is supplied with instructions.\u003c\/p\u003e\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca target=\"_blank\" href=\"https:\/\/manuals.hannainst.com\/HI8614LN\"\u003epH Transmitter with 4-20 mA Galvanically Isolated Output - HI8614-With LCD\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871418515825,"sku":"HI8614LN","price":63026.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi8614l_n_1_1.jpg?v=1792646588","url":"https:\/\/hannainst.in\/products\/ph-transmitter-with-4-20-ma-galvanically-isolated-output-hi8614-with-lcd","provider":"hanna","version":"1.0","type":"link"}