{"product_id":"standard-automatic-potentiometric-titrator-hi930","title":"Standard Automatic Potentiometric Titrator-HI930","description":"\u003cstyle\u003e\n  .hanna-product-description {\n    color: #333;\n    line-height: 1.6;\n  }\n\n  .hanna-product-description h2 {\n    font-size: 28px;\n    line-height: 1.3;\n    margin: 40px 0 20px;\n    color: #222;\n  }\n\n  .hanna-subheading {\n    font-size: 21px;\n    line-height: 1.4;\n    font-weight: 600;\n    margin: 25px 0 12px;\n    color: #222;\n  }\n\n  .hanna-product-description p {\n    margin: 0 0 18px;\n  }\n\n  .hanna-product-description ul {\n    margin: 0 0 25px;\n    padding-left: 25px;\n  }\n\n  .hanna-product-description li {\n    margin-bottom: 10px;\n  }\n\n  .hanna-intro {\n    margin-bottom: 35px;\n  }\n\n  .hanna-highlight-box {\n    background: #f5f7f8;\n    border-left: 4px solid #0076a8;\n    padding: 25px;\n    margin: 25px 0;\n  }\n\n  .hanna-feature {\n    margin-bottom: 28px;\n  }\n\n  .hanna-feature .hanna-subheading {\n    margin-bottom: 8px;\n  }\n\n  .hanna-industries {\n    display: grid;\n    grid-template-columns: repeat(4, 1fr);\n    gap: 15px;\n    margin: 25px 0 40px;\n  }\n\n  .hanna-industry {\n    background: #f5f5f5;\n    padding: 18px;\n    text-align: center;\n    font-weight: 600;\n    border-radius: 4px;\n  }\n\n  .hanna-comparison,\n  .hanna-specs,\n  .hanna-manual-auto {\n    width: 100%;\n    border-collapse: collapse;\n    margin: 25px 0 40px;\n    font-size: 14px;\n  }\n\n  .hanna-comparison th,\n  .hanna-comparison td,\n  .hanna-specs th,\n  .hanna-specs td,\n  .hanna-manual-auto th,\n  .hanna-manual-auto td {\n    border: 1px solid #ddd;\n    padding: 12px;\n    text-align: left;\n    vertical-align: top;\n  }\n\n  .hanna-comparison th,\n  .hanna-specs th,\n  .hanna-manual-auto th {\n    background: #f2f2f2;\n    font-weight: 700;\n  }\n\n  .hanna-specs th {\n    width: 32%;\n  }\n\n  .hanna-manual-auto th {\n    font-size: 18px;\n  }\n\n  .hanna-included {\n    background: #fafafa;\n    padding: 25px;\n    border: 1px solid #ddd;\n    margin-bottom: 40px;\n  }\n\n  .hanna-note {\n    font-size: 13px;\n    color: #666;\n  }\n\n  @media (max-width: 768px) {\n\n    .hanna-product-description h2 {\n      font-size: 24px;\n    }\n\n    .hanna-subheading {\n      font-size: 19px;\n    }\n\n    .hanna-industries {\n      grid-template-columns: 1fr 1fr;\n    }\n\n    .hanna-comparison,\n    .hanna-specs,\n    .hanna-manual-auto {\n      font-size: 13px;\n    }\n\n    .hanna-comparison th,\n    .hanna-comparison td,\n    .hanna-specs th,\n    .hanna-specs td,\n    .hanna-manual-auto th,\n    .hanna-manual-auto td {\n      padding: 9px;\n    }\n  }\n\n  @media (max-width: 480px) {\n\n    .hanna-industries {\n      grid-template-columns: 1fr;\n    }\n\n    .hanna-comparison,\n    .hanna-specs,\n    .hanna-manual-auto {\n      display: block;\n      overflow-x: auto;\n      white-space: nowrap;\n    }\n  }\n\u003c\/style\u003e\n\u003cdiv class=\"hanna-product-description\"\u003e\n\u003c!-- INDUSTRIES --\u003e\n\u003ch2\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Hanna12432-1290x821_da3f1bb4-c57f-446d-b39b-3cc10f56af81.jpg?v=1789966462\" alt=\"\"\u003e\u003c\/h2\u003e\n\u003ch2\u003eWhich industries use Automatic Titrators?\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-industries-1024x1024_c3b58256-1c21-4c8c-b065-18c6ad57915f.jpg?v=1789966494\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-industries\"\u003e\n\u003cdiv class=\"hanna-industry\"\u003eFood\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eBeverage Manufacturing\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eLaboratory\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eEducation and Research\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eIndustrial\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003ePetrochemical\u003c\/div\u003e\n\u003cdiv class=\"hanna-industry\"\u003eMunicipalities\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c!-- SPACE SAVING --\u003e\n\u003ch2\u003eSave Valuable Lab Space\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-stirre_caba5c30-3852-4c2e-a2aa-d5605e1efa0e.png?v=1789966545\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eA Simple Setup for Easy Integration\u003c\/div\u003e\n\u003cp\u003eWe thoughtfully designed this automatic titration system to have a small footprint. The flexible electrode holder and magnetic stirrer are directly built into the top of the titrator unit instead of on the side. This ensures that the titrator requires minimal space in a laboratory setting, helping improve workflow and increase productivity.\u003c\/p\u003e\n\u003c!-- FEATURES --\u003e\n\u003ch2\u003eAuto Titrator Features at a Glance\u003c\/h2\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eTough Cycoloy® Body and Chemically Resistant Tubing\u003c\/div\u003e\n\u003cp\u003eDurable, heat-resistant and resistant to staining. The titrator menu buttons are part of the display, making it fully sealed and easy to clean.\u003c\/p\u003e\n\u003cp\u003eAspiration and dispensing tubes are constructed of chemically resistant PTFE and feature a light-blocking polyurethane outer sleeve to protect light-sensitive reagents.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eA Flexible Electrode Holder with Adjustable Arm\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eUse electrodes with different diameters by simply changing the electrode guide.\u003c\/li\u003e\n\u003cli\u003eCreate the best tube alignment for your titration with a rotating holder. There is no need to move electrodes around.\u003c\/li\u003e\n\u003cli\u003eConveniently modify the height of the electrode holder using the adjustable arm and press-to-release button.\u003c\/li\u003e\n\u003cli\u003ePositions the electrodes in the center of the beaker, allowing for smaller sample sizes.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eMagnetic Stirrer\u003c\/div\u003e\n\u003cp\u003eStirring ensures uniform mixing of the titrant and sample, allowing the reaction to reach completion.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003e40,000-Step Dosing Pump\u003c\/div\u003e\n\u003cp\u003eCapable of dosing extremely small volumes of titrant so you can achieve a very precise endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eMultiple Titration Types\u003c\/div\u003e\n\u003cp\u003ePaired with the right electrode, this potentiometric titrator can perform a variety of standard titrations, including pH and mV tests with fixed endpoints or single equivalence points.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eDynamic Titrant Dosing\u003c\/div\u003e\n\u003cp\u003eGuarantees timely and accurate results by relating the titrant volume dosed to the mV response from the titration reaction. This allows larger doses at the beginning of a titration and smaller, more precise doses near the titration endpoint.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eEquivalence Endpoint Detection\u003c\/div\u003e\n\u003cp\u003eCrucial for applications where fixed endpoints are not specified in standard methods. This endpoint indicates where the mV response from the titration is greatest with respect to the volume of titrant dosed.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eSignal Stability Timing\u003c\/div\u003e\n\u003cp\u003eMonitors when the mV response of the titration reaction stabilizes before providing the next titrant dose. This ensures dependable measurement values throughout the titration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eClip Lock™ Exchangeable Burette System\u003c\/div\u003e\n\u003cp\u003eWith this special feature, it only takes a few seconds to exchange titrants and reagents, helping prevent cross-contamination. An audible clicking sound confirms that the Clip Lock is securely in place.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eGutters and Wells\u003c\/div\u003e\n\u003cp\u003eProvides optimal protection against spills. An external gutter system shields important connections from spills, while interior trays help safeguard internal electronics.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"hanna-feature\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eSecurity Options for Users\u003c\/div\u003e\n\u003cp\u003eDetermine appropriate permission settings for each user, administrator, or non-administrator level to prevent unwanted edits or changes to titration method options and results.\u003c\/p\u003e\n\u003cp\u003eAdministrators can also set a PIN code on the titrator unit to protect against unauthorized access.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-designed-for-dynamic-environments-704x1024_7fdbcdb8-b26f-4fc1-8182-3f15678d5180.jpg?v=1789966588\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c!-- PH METER --\u003e\n\u003ch2\u003eGet More Done\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-electrode-holder-head-raised-800-627x1024_93388bc5-722a-4318-9cae-4447ed072337.jpg?v=1789966638\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eDoubles as a Research-Grade pH\/mV Meter\u003c\/div\u003e\n\u003cp\u003eWith our versatile Automatic Titrator, multiple analyses can be performed using one sample. This unit functions not only as a titrator, but also as a pH meter and mV\/ORP meter.\u003c\/p\u003e\n\u003cp\u003eHanna Instruments offers a variety of compatible BNC pH electrodes to choose from, allowing you to select the electrode best suited to your application.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI930-SCREENS-ph-Calibration_08e64a48-2d76-42f2-972d-ef10a6fe055f.jpg?v=1789966620\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c!-- MANUAL VS AUTOMATIC --\u003e\n\u003ch2\u003eWhy Switch from Manual to Automatic Titration?\u003c\/h2\u003e\n\u003ctable class=\"hanna-manual-auto\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eManual Titration\u003c\/th\u003e\n\u003cth\u003eAutomatic Titration\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Interpreting Results By Eye Is Tricky and Can Vary \u003c\/strong\u003e\n\u003cp\u003eIndicator colors used to determine the endpoint are subjective and can look different to each operator.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Monitors and Detects the Exact Endpoint for You \u003c\/strong\u003e\n\u003cp\u003eEliminate the guesswork. Once the titration is complete, a digital result is displayed on the easy-to-read screen.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Inconsistent Results and Room for Error \u003c\/strong\u003e\n\u003cp\u003eSeveral operator shift changes can occur in a laboratory, making it difficult to attain reproducible measurements.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Achieve Repeatable Results at the Push of a Button \u003c\/strong\u003e\n\u003cp\u003eUsers can perform and replicate tests the same way each time with high accuracy.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Inconvenient and Inefficient \u003c\/strong\u003e\n\u003cp\u003eManual titrations are time-consuming and require your full attention. Over-titrating and re-running titrations can occur.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Free Up Your Time and Increase Productivity \u003c\/strong\u003e\n\u003cp\u003eAn Automatic Titrator performs the bulk of the work for you. While a titration is running, you can focus on other tasks.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Record Keeping Is a Hassle \u003c\/strong\u003e\n\u003cp\u003eData is documented by hand in a laboratory notebook or entered digitally. Both approaches can be prone to mistakes.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Gain Complete Data Traceability \u003c\/strong\u003e\n\u003cp\u003eGenerate detailed digital reports. Required data is automatically stored for each application and GLP information is recorded.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Increases Chemical Consumption and Expenses \u003c\/strong\u003e\n\u003cp\u003eA high volume of titrant may be needed to compensate for the inability to deliver small doses.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd\u003e\n\u003cstrong\u003e Reduce Titrant and Sample Usage \u003c\/strong\u003e\n\u003cp\u003eThe system can dose extremely small volumes of titrant into small sample sizes, helping minimize waste.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- TRACEABLE DATA --\u003e\n\u003ch2\u003eStay Compliant with Traceable Data Right at Your Fingertips\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi930-usb_f26501a1-0790-4cfb-a1c5-2f51839563f8.jpg?v=1789966689\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"hanna-subheading\"\u003ePrepare for Audits and Meet Requirements\u003c\/div\u003e\n\u003cp\u003eStore up to 50 titration and pH\/mV customizable analysis reports and simply transfer data via USB.\u003c\/p\u003e\n\u003cp\u003eInformation such as date, time, method settings, results and calibration data are recorded with each sample.\u003c\/p\u003e\n\u003cp\u003eIn addition, a real-time titration curve can be displayed during each titration. This is useful when new methods are tested or when a procedure requires optimization.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Screenshot-2026-06-17-141017_3b3f702e-701c-421b-9d63-05993c2d2f54.jpg?v=1789966722\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c!-- APPLICATIONS --\u003e\n\u003ch2\u003eApplications and Standard Methods\u003c\/h2\u003e\n\u003ctable class=\"hanna-comparison\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eIndustry\u003c\/th\u003e\n\u003cth\u003eParameter\u003c\/th\u003e\n\u003cth\u003eSample\u003c\/th\u003e\n\u003cth\u003eStandard Methods\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGovernment\u003c\/td\u003e\n\u003ctd\u003eAcid Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D4662\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkali, Free \u0026amp; Total\u003c\/td\u003e\n\u003ctd\u003ePlating Baths\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eMineral Carbonized Concrete\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWater Treatment\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironmental\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFood\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBeverage\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAlkalinity\u003c\/td\u003e\n\u003ctd\u003eWater\/Wastewater, Food\/Beverage\u003c\/td\u003e\n\u003ctd\u003e—\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLaboratory\u003c\/td\u003e\n\u003ctd\u003eAmine Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D6979\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIndustrial\u003c\/td\u003e\n\u003ctd\u003eAmine Value\u003c\/td\u003e\n\u003ctd\u003ePolyols\u003c\/td\u003e\n\u003ctd\u003eASTM D6979\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- HI930 COMPARISON --\u003e\n\u003ch2\u003eWhich Hanna Instruments Automatic Titrator Is Best for Your Testing Needs?\u003c\/h2\u003e\n\u003cp\u003eThe following comparison provides an overview of the HI930, HI931 and HI932 automatic titrators and their capabilities.\u003c\/p\u003e\n\u003ctable class=\"hanna-comparison\"\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eFeature\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eHI930\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/957b8414-c6ae-4cf8-ac41-e0fac67228dc_2e86f625-4716-4dcf-b360-f2026c4ef571.jpg?v=1789966761\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eHI931\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/81fc29c3-4b76-4fd7-b0a9-ac24e342b708_a496a8e0-605f-4238-99e4-790b4880f6ab.jpg?v=1789966786\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth\u003e\n\u003cp\u003eHI932\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ad4ea1d0-5f85-4e21-92b6-437ae561de8e_5c9d06f6-b44e-497d-b10c-3a8fbbc51970.jpg?v=1789966810\" alt=\"\"\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Boards\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Pump Capability (max.)\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePeristaltic Pump Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCompatible Electrodes\u003c\/td\u003e\n\u003ctd\u003epH, ORP\u003c\/td\u003e\n\u003ctd\u003epH, ORP, ISE, Photometric\u003c\/td\u003e\n\u003ctd\u003epH, ORP, ISE, Photometric\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Electrode Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAutosampler Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Capability\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e1\u003c\/td\u003e\n\u003ctd\u003e2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Type\u003c\/td\u003e\n\u003ctd\u003eMagnetic\u003c\/td\u003e\n\u003ctd\u003eOverhead Propeller\u003c\/td\u003e\n\u003ctd\u003eOverhead Propeller\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eStirrer Location\u003c\/td\u003e\n\u003ctd\u003eIntegrated, on top\u003c\/td\u003e\n\u003ctd\u003eOn the side\u003c\/td\u003e\n\u003ctd\u003eOn the side\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLIMS Capability\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eYes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePrinter Connection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eDB-25 Parallel Port\u003c\/td\u003e\n\u003ctd\u003eUSB-A on Network Box\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBalance Connection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003ctd\u003eRS-232\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eKeyboard Connection\u003c\/td\u003e\n\u003ctd\u003eUSB-A (hot swap)\u003c\/td\u003e\n\u003ctd\u003eUSB-A (hot swap) \/ PS\/2\u003c\/td\u003e\n\u003ctd\u003eUSB-A (hot swap) \/ USB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePC Software Connection\u003c\/td\u003e\n\u003ctd\u003eNo\u003c\/td\u003e\n\u003ctd\u003eUSB-B\u003c\/td\u003e\n\u003ctd\u003eUSB-C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum No. of Methods\u003c\/td\u003e\n\u003ctd\u003e15\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMaximum No. of Reports\u003c\/td\u003e\n\u003ctd\u003e50\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003ctd\u003e100\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003cp class=\"hanna-note\"\u003e* All titrators are compatible with the Silver Billet HI148B.\u003c\/p\u003e\n\u003cp class=\"hanna-note\"\u003e** Adapter required for photometric connection on the HI932 Automatic Titrator.\u003c\/p\u003e\n\u003cp class=\"hanna-note\"\u003e*** With the network box you can transfer to a PC and print directly; network box sold separately.\u003c\/p\u003e\n\u003c!-- WHAT'S INCLUDED --\u003e\n\u003ch2\u003eWhat's Included\u003c\/h2\u003e\n\u003cdiv class=\"hanna-included\"\u003e\n\u003cul\u003e\n\u003cli\u003eStandard Automatic Potentiometric Titrator (HI930)\u003c\/li\u003e\n\u003cli\u003ePump assembly\u003c\/li\u003e\n\u003cli\u003eBurette assembly kit including burette with 25 mL syringe, aspiration tube with fitting and protection tube, dispensing tube with dispensing tip, protection tube and tube guide, tube locks, tool for burette cap removal and light spectrum protection\u003c\/li\u003e\n\u003cli\u003ePlastic beaker, 100 mL – 3 pcs.\u003c\/li\u003e\n\u003cli\u003eBeaker support\u003c\/li\u003e\n\u003cli\u003eElectrodes holder and support rod with positioning collar and screw\u003c\/li\u003e\n\u003cli\u003eMagnetic stirrer – 1 pc.\u003c\/li\u003e\n\u003cli\u003eStir bars – 2 pcs.\u003c\/li\u003e\n\u003cli\u003ePump and burette locking screws with plastic head\u003c\/li\u003e\n\u003cli\u003eTemperature sensor – 1 pc.\u003c\/li\u003e\n\u003cli\u003eShorting cap – 1 pc.\u003c\/li\u003e\n\u003cli\u003eO-ring set – 5 × 10.5 mm + 5 × 3 mm\u003c\/li\u003e\n\u003cli\u003ePower adapter – 1 pc.\u003c\/li\u003e\n\u003cli\u003eUSB memory stick – 1 pc.\u003c\/li\u003e\n\u003cli\u003eInstrument quality certificate – 1 pc.\u003c\/li\u003e\n\u003cli\u003eInstruction manual – 1 pc.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c!-- SPECIFICATIONS --\u003e\n\u003ch2\u003eSpecifications\u003c\/h2\u003e\n\u003ctable class=\"hanna-specs\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth\u003eAnalysis Type\u003c\/th\u003e\n\u003ctd\u003eStandard titration (Standardization, Fixed pH\/mV, Equivalence point pH\/mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEndpoint Mode\u003c\/th\u003e\n\u003ctd\u003eFixed mV\u003cbr\u003eFixed pH\u003cbr\u003emV equivalence point (1st or 2nd derivative)\u003cbr\u003epH equivalence point (1st or 2nd derivative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Size\u003c\/th\u003e\n\u003ctd\u003e5 mL, 10 mL, 25 mL, 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Resolution\u003c\/th\u003e\n\u003ctd\u003e0.001 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Flow Rate\u003c\/th\u003e\n\u003ctd\u003e0.1\/0.3 mL to 2 × burette volume per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eBurette Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.005 mL (5 mL burette)\u003cbr\u003e±0.010 mL (10 mL burette)\u003cbr\u003e±0.025 mL (25 mL burette)\u003cbr\u003e±0.050 mL (50 mL burette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStirrer Type\u003c\/th\u003e\n\u003ctd\u003eIntegrated magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStirrer Range\u003c\/th\u003e\n\u003ctd\u003e200 to 1400 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStirrer Resolution\u003c\/th\u003e\n\u003ctd\u003e100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Range\u003c\/th\u003e\n\u003ctd\u003e−2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003emV Calibration\u003c\/th\u003e\n\u003ctd\u003eSingle point, offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Range\u003c\/th\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003epH Calibration\u003c\/th\u003e\n\u003ctd\u003eUp to 5 points with standard or custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Range\u003c\/th\u003e\n\u003ctd\u003e−5.0 to 105 °C\u003cbr\u003e23.0 to 221.0 °F\u003cbr\u003e268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Resolution\u003c\/th\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eTemperature Accuracy\u003c\/th\u003e\n\u003ctd\u003e±0.1 °C \/ ±0.2 °F \/ ±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Storage Methods\u003c\/th\u003e\n\u003ctd\u003eUp to 15 titration methods (standard and user-defined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eData Storage Reports\u003c\/th\u003e\n\u003ctd\u003eUp to 50 titrations and pH\/mV reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections – Measurement\u003c\/th\u003e\n\u003ctd\u003e1 × BNC socket (pH, ORP electrodes)\u003cbr\u003e1 × 4 mm banana socket (reference electrode)\u003cbr\u003e1 × RCA socket (temperature sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eConnections – Peripheral\u003c\/th\u003e\n\u003ctd\u003e1 × USB standard A (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eElectrode Holder\u003c\/th\u003e\n\u003ctd\u003e4 × multi-purpose slots (titrant tubes)\u003cbr\u003e4 × 12-mm electrode slots (3 integrated, 1 with included adapter)\u003cbr\u003e1 × temperature sensor slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDisplay\u003c\/th\u003e\n\u003ctd\u003e5.7 in. graphical color display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Supply\u003c\/th\u003e\n\u003ctd\u003e100 – 240 VAC, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003ePower Draw\u003c\/th\u003e\n\u003ctd\u003e0.5 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eEnclosure Material\u003c\/th\u003e\n\u003ctd\u003eABS, PC-ABS, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eKeypad\u003c\/th\u003e\n\u003ctd\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eDimensions\u003c\/th\u003e\n\u003ctd\u003e315 × 205 × 375 mm (12.4 × 8.1 × 14.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eWeight\u003c\/th\u003e\n\u003ctd\u003eApproximately 3.6 kg (7.9 lbs.) with burette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eOperating Environment\u003c\/th\u003e\n\u003ctd\u003e10 to 40 °C (50 to 104 °F), up to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eStorage Environment\u003c\/th\u003e\n\u003ctd\u003e−20 to 70 °C (−4 to 158 °F), up to 95% RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c!-- FINAL --\u003e\n\u003cdiv class=\"hanna-highlight-box\"\u003e\n\u003cdiv class=\"hanna-subheading\"\u003eStandard Automatic Potentiometric Titrator – HI930\u003c\/div\u003e\n\u003cp\u003eThe HI930 provides a compact and versatile solution for laboratories requiring accurate, repeatable and traceable automatic titration. With precise dosing, multiple titration modes, integrated stirring, pH\/mV measurement and digital data storage, it is designed to simplify routine laboratory analysis.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003csection class=\"banner--product-resources\" style=\"color: #000000;\"\u003e\n\u003cdiv class=\"custom-fields\"\u003e\n\u003cdiv class=\"flex-center\"\u003e\n\u003cdiv class=\"resources-container\"\u003e\n\u003cdiv class=\"tabs-content\" style=\"color: inherit;\"\u003e\n\u003cdiv id=\"specifications-accordion\" class=\"tabs-panel is-active\" role=\"tabpanel\"\u003e\n\u003cdiv class=\"grid-container\"\u003e\n\u003cdiv class=\"table-specs\"\u003e\n\u003ctable\u003e\n\u003cthead\u003e\n\u003ctr\u003e\n\u003cth\u003eSpecification\u003c\/th\u003e\n\u003cth\u003eDetail\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003c\/thead\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eAnalysis Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eStandard titration (Standardization, Fixed pH\/mV, Equivalence point pH\/mV)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eEndpoint Mode\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eFixed mV Fixed pH mV equivalence point (1st or 2nd derivative) pH equivalence point (1st or 2nd derivative)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Size\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5 mL, 10 mL, 25 mL, 50 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.001 mL\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Flow rate\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1\/0.3 mL to 2 × burette volume per minute\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eBurette Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.005 mL (5 mL burette) ±0.010 mL (10 mL burette) ±0.025 mL (25 mL burette) ±0.050 mL (50 mL burette)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStirrer Type\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eIntegrated magnetic\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStirrer Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e200 to 1400 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStirrer Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 RPM\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−2000.0 to 2000.0 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003emV Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eSingle point, offset\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−2.000 to 20.000 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1 \/ 0.01 \/ 0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.001 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003epH Calibration\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 5 points with standard or custom buffers\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Range\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−5.0 to 105 °C 23.0 to 221.0 °F 268.2 to 378.2 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Resolution\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eTemperature Accuracy\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e±0.1 °C \/ ±0.2 °F \/ ±0.1 K\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eData Storage Methods\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 15 titration methods (standard and user-defined)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eData Storage Reports\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eUp to 50 titrations and pH\/mV reports\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eConnections Measurement\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × BNC socket (pH, ORP electrodes) 1 × 4 mm banana socket (reference electrode) 1 × RCA socket (temperature sensor)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eConnections Peripheral\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e1 × USB standard A (USB flash drive)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eElectrode Holder\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e4 × multi-purpose slots (titrant tubes) 4 × 12-mm electrode slots (3 integrated, 1 with included adapter) 1 × temperature sensor slot\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eDisplay\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e5.7 in. graphical color display with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Supply\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e100 – 240 VAC, 50 \/ 60 Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003ePower Draw\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e0.5 amps\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eEnclosure Material\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eABS, PC-ABS, stainless steel\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eKeypad\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003ePolyester\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eDimensions\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e315 x 205 x 375 mm (12.4 x 8.1 x 14.8 in.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eWeight\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003eApproximately 3.6 kg (7.9 lbs.) with burette\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eOperating Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e10 to 40 °C (50 to 104 °F), up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd style=\"width: 250px;\"\u003e\u003cstrong\u003eStorage Environment\u003c\/strong\u003e\u003c\/td\u003e\n\u003ctd\u003e−20 to 70 °C (−4 to 158 °F), up to 95 % RH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/section\u003e\n\u003cdiv style=\"color: #000000;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv style=\"color: #000000;\"\u003e\u003cbr\u003e\u003c\/div\u003e\n\u003cdiv class=\"tabs-contents\" style=\"color: #000000;\"\u003e\n\u003cdiv id=\"tab-related\" class=\"tab-content has-jsContent is-active\" role=\"tabpanel\"\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/pages.hannainst.com\/hubfs\/product-manuals\/MAN930_01_26.pdf?__hstc=4846506.88f998383056e7a1dc413c6f6ed9074c.1781604137253.1781604137253.1781681130757.2\u0026amp;__hssc=4846506.1.1781681130757\u0026amp;__hsfp=ee46b245bab50259c1a5d23673c0a667\"\u003eStandard Automatic Potentiometric Titrator Manual (HI930)\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461769585,"sku":"HI930","price":706978.13,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI930-Automatic-Potentiometric-Titrator_Right-Facing-2026__99768.jpg?v=1792646984","url":"https:\/\/hannainst.in\/products\/standard-automatic-potentiometric-titrator-hi930","provider":"hanna","version":"1.0","type":"link"}