{"product_id":"tds-mini-controller-0-0-to-199-9-ppm-bl983315-2-230-vac-output-4-20-ma","title":"TDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 230 VAC,  Output: 4-20 mA","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eThis compact, panel mounted, process controller is ideal for measuring total dissolved solids (TDS) of a process stream. This controller features a large LCD with protective cover. Users may choose from automatic or manual dosing modes.\u003c\/p\u003e\n\u003cp\u003eWhen in automatic mode, the dry contact relay is activated when a reading is above the set point. The relay can be used to supply power to a dosing pump or a solenoid connected to a valve. The BL983315 can also be used to monitor the quality of water produced from ion exchange, reverse osmosis (RO) or distillation.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_angle.jpg\" alt=\"BL983315\" width=\"500\" height=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eAdjustable Dry Contact Dosing Relay\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 features a dosing relay that is activated when the reading is above a user programmable set point.\u003c\/p\u003e\n\u003ch4\u003eProgrammable Overdose Protection\u003c\/h4\u003e\n\u003cp\u003eFor enhanced safety the mini controller can be programmed to deactivate the dosing relay if the set point is not reached within a specified time interval. The overdosing timer is programmable from 5 to 30 minutes or disabled.\u003c\/p\u003e\n\u003ch4\u003eRelay Control Override\u003c\/h4\u003e\n\u003cp\u003eWith the flick of a switch the mini controller's relay can be disabled (Off), placed in control (Auto), or be activated for manual operation (On) which is useful for priming a dosing pump.\u003c\/p\u003e\n\u003ch4\u003eMulticolor LED Indicator\u003c\/h4\u003e\n\u003cp\u003eMulticolor LED indicator allows an operator to quickly check the status of the controller.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eGreen = Meter in measurement mode and reading is below the set point.\u003c\/li\u003e\n\u003cli\u003eOrange\/Yellow = Reading is above the set point and the relay is activated.\u003c\/li\u003e\n\u003cli\u003eBlinking Red = Indicates an alarm condition such as when the maximum dosing time has been exceeded.\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px; flex-direction: row-reverse;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315_rear.jpg\" alt=\"BL983315\" width=\"500\" height=\"500\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003eFuse Protected Dosing Contacts\u003c\/h4\u003e\n\u003cp\u003eThe relay dosing contact is rated for up to a 2A load and is fuse protected.\u003c\/p\u003e\n\u003cp\u003eBL983315 uses a 0.5 conversion factor in which 1.0 µS\/cm = 0.5 ppm.\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eModel available with 4-20 mA galvanic isolated output with external dosing disable contact\u003c\/li\u003e\n\u003cli\u003eLarge Clear LCD\u003c\/li\u003e\n\u003cli\u003eFire Retardant Casing\u003c\/li\u003e\n\u003cli\u003eSplash-Resistant Cover\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch4\u003eLabeled Termination Connections\u003c\/h4\u003e\n\u003cp\u003eQuick-connect terminal blocks are clearly labeled for easy connection to power, conductivity probe and relay that can be used to operate a dosing pump, valve, audible alarm, or light.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI7634-00_1.jpg\" alt=\"HI7634\" width=\"600\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin-top: 0;\"\u003e1\/2\" NPT Male Threaded Amperometric Probe for Mounting In-line*\u003c\/h4\u003e\n\u003cp\u003eThe BL983315 mini controller uses the \u003cstrong\u003eHI7634\u003c\/strong\u003e conductivity probe that is available with different cable lengths.\u003c\/p\u003e\n\u003ch4\u003e*HI7634 is not included and must be ordered separately\u003c\/h4\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eBL983315-2\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eTDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 230 VAC, Output: 4-20 mA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 199.9 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 ppm (mg\/L)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% f.s.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTDS Calibration\u003c\/td\u003e\n\u003ctd\u003emanual, with CAL trimmer\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eautomatic from 5 to 50°C (41 to 122°F) with β =2%\/℃\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC to TDS Conversion Factor\u003c\/td\u003e\n\u003ctd\u003e0.5\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Relay\u003c\/td\u003e\n\u003ctd\u003emaximum 2A (fuse protected), 250 Vac, 30 VDC\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEC\/TDS Dosing Set Point\u003c\/td\u003e\n\u003ctd\u003eadjustable from 0 to 199.9 mg\/L (ppm)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 12 VDC adapter (included)\nmodels “-1”: 115\/230 VAC; 50\/60Hz\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e83 x 53 x 99 mm (3.3 x 2.1 x 3.9”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003emodels “-0”: 200 g (7.1 oz.) models “-1”: 300 g (10.6 oz.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/BL983315-2\" target=\"_blank\" rel=\"noopener\"\u003eTDS Mini Controller (0.0 to 199.9 ppm) - BL983315-2 | 115\/230 VAC, Output: 4-20 mA\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871166038385,"sku":"BL983315-2","price":33427.35,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/BL983315-2.png?v=1792645812","url":"https:\/\/hannainst.in\/products\/tds-mini-controller-0-0-to-199-9-ppm-bl983315-2-230-vac-output-4-20-ma","provider":"hanna","version":"1.0","type":"link"}