{"product_id":"universal-process-controller-hi510","title":"Universal Process Controller - HI510 - HI510-0540","description":"\u003cdiv style=\"margin: 0 0 48px;\"\u003e\n\u003cp\u003eHI510 is an advanced universal process controller that can be configured for many applications requiring monitoring and\/or control of process parameters. It features a digital probe input that will automatically detect and update the controller with the parameter that it measures.\u003c\/p\u003e\n\u003cp\u003eThis controller can be configured with up to 5 control relays and 4 analog outputs. The control relays can be programmed for on\/off, Proportional, or PID (Proportional Integral Derivative) types of control or used for programming cleaning sequences triggered by a digital input or based on a schedule. The scalable analog outputs can be used for remote devices including Chart recorders, PLC, or SCADA. The analog outputs can be used for control devices including dosing pumps and valves that accept a 0\/4-20 mA output.\u003c\/p\u003e\n\u003cp\u003eHI510 features a RS485 digital output that allows up to 32 devices to be connected to a single line that can be viewed and programmed remotely using the HI92500 software. The HI92500software provides for graphic user interface that allows for settings to be changed and saved for transfer to another HI510 controller.\u003c\/p\u003e\n\u003cp\u003eThe HI510 NEMA 4X enclosure uses sealed cable glands to maintain waterproof integrity. The versatile mounting kits allow for mounting the HI510 to a wall, pipe and panel.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: grid; grid-template-columns: repeat(auto-fit, minmax(min(100%, 440px), 1fr)); gap: 36px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI510-display.gif\" alt=\"HI510 front\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eGeneral Design Features\u003c\/h4\u003e\n\u003ch4\u003eBacklit Dot Matrix LCD with LED indicators\u003c\/h4\u003e\n\u003cp\u003eLarge backlit LCD with visual indicators for meter status, alarm and relay activation.\u003c\/p\u003e\n\u003ch4\u003eNEMA 4X Enclosure\u003c\/h4\u003e\n\u003cp\u003e½ DIN NEMA 4X enclosure suitable for outside and industrial environments.\u003c\/p\u003e\n\u003ch4\u003eVersatile Mounting Options\u003c\/h4\u003e\n\u003cp\u003eChoose from wall, pipe or panel mounted options.\u003c\/p\u003e\n\u003ch2\u003eUSB-C Connectivity\u003c\/h2\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/510_USBC.jpg\" alt=\"\" width=\"85\" height=\"60\" loading=\"lazy\" style=\"display: inline-block; max-width: 100%; height: auto; border: 0;\"\u003e\u003c\/p\u003e\n\u003ch4\u003eFlash Drive Compatible\u003c\/h4\u003e\n\u003cp\u003eTransfer of logged data and events to a flash drive as a .csv file for review on Window’s, OS X, or Linux based computers.\u003c\/p\u003e\n\u003ch4\u003eLogged Data\u003c\/h4\u003e\n\u003cp\u003eStore information at selectable intervals along with relay control settings and calibrations data. Information can be stored in up to 100 lots, each holding 8600 records.\u003c\/p\u003e\n\u003ch4\u003eEvent Management System\u003c\/h4\u003e\n\u003cp\u003eLogged events includes any changes made, alarm, error and warning activations, and calibration information.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI510-2Analog-DoorOpen-ClosedRelay.jpg\" alt=\"HI510 low voltage connections\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eLow Voltage Connections\u003c\/h4\u003e\n\u003ch4\u003eIsolated High Voltage Section\u003c\/h4\u003e\n\u003cp\u003eTo reduce the risk to shock the low voltage connection area is isolated from high voltage area.\u003c\/p\u003e\n\u003ch4\u003eRS485 Digital Connectivity\u003c\/h4\u003e\n\u003cp\u003eRS485 output for connecting up to 32 devices for remote monitoring and programming.\u003c\/p\u003e\n\u003ch4\u003eDigital Inputs and Analog Outputs\u003c\/h4\u003e\n\u003cp\u003eDigital probe input, digital trigger inputs, and analog outputs utilize extractable terminal blocks for simplified wiring.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: flex-start; gap: 16px 24px;\"\u003e\n\u003cdiv style=\"flex: 0 0 140px; max-width: 100%; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/510_open_Fuse-Panel.jpg\" alt=\"HI510 high voltage connections\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 200px; min-width: 0;\"\u003e\n\u003ch4 style=\"margin: 0 0 8px; font-size: 18px; line-height: 1.3;\"\u003eHigh Voltage Connections\u003c\/h4\u003e\n\u003ch4\u003eReplaceable Slow Blow Fuses\u003c\/h4\u003e\n\u003cp\u003eAll relays and the line power input are protected by replaceable 5A slow blow fuses.\u003c\/p\u003e\n\u003ch4\u003eSPDT and SPST Programmable Relays\u003c\/h4\u003e\n\u003cp\u003eUp to 5 relays that can be programmed for control or washing sequences.\u003c\/p\u003e\n\u003ch4\u003eFail Safe Alarm Technology\u003c\/h4\u003e\n\u003cp\u003eFail Safe Alarm Technology that deactivates relay from normal open state to normally closed to supply power to remote alarm device.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv style=\"display: flex; flex-wrap: wrap; align-items: center; justify-content: center; gap: 24px 48px; margin: 0 0 48px;\"\u003e\n\u003cdiv style=\"flex: 1 1 260px; max-width: 440px; text-align: center;\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/setpoint2.jpg\" alt=\"HI510 Programming Options\" width=\"100\" loading=\"lazy\" style=\"display: block; max-width: 100%; height: auto; margin: 0 auto;\"\u003e\u003c\/div\u003e\n\u003cdiv style=\"flex: 1 1 340px; min-width: 0;\"\u003e\n\u003ch2 style=\"margin-top: 0;\"\u003eProgramming HI510 remotely using HI92500 Software\u003c\/h2\u003e\n\u003ch4\u003eRelay Control Modes\u003c\/h4\u003e\n\u003cp\u003eSet points for control operations can be configured to be on\/off, proportional, or PID types of control. The flexibility in programming allows for fine-tuning of a set point to be maintained with tight control preventing any overshoot and waste of chemicals.\u003c\/p\u003e\n\u003ch4\u003eConfigurable Alarm System\u003c\/h4\u003e\n\u003cp\u003eConfigurable for set points and temperature or activated by abnormal operation, a red Alarm LED will blink and can easily be seen from a distance. All relays configured for control are inactivated until the alarm state is resolved.\u003c\/p\u003e\n\u003ch4\u003eAuto-cleaning cycle\u003c\/h4\u003e\n\u003cp\u003eThe cleaning function allows the ability to program one or more wash cycles and use the relays to activate valves, pumps or compressed air based on the type of washing that is required to maintain probes for reliable results.\u003c\/p\u003e\n\u003ch4\u003eScalable Analog Outputs\u003c\/h4\u003e\n\u003cp\u003eAnalog outputs can be scaled to assign 0 to 20 mA or 4-20 mA to a specific range for increased resolutions. Analog outputs can be programmed to send 22 mA signal when placed in hold status during maintenance including calibration.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eUniversal Process Controller - HI510\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Control\u003c\/td\u003e\n\u003ctd\u003eon\/off, proportional and PID\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDosing Terminals\u003c\/td\u003e\n\u003ctd\u003eUp to 5 relays (independently configurable for process variables, Hold \u0026amp; Cleaning functions)\nElectromechanical relay SPDT and SPST contact outputs\n5A – 250 Vac; 5A – 30 Vdc (resistive load)\nFuse protected: 5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlarm Relay Set Point\u003c\/td\u003e\n\u003ctd\u003eUp to 5 relays (independently configurable for process variables, Hold \u0026amp; Cleaning functions)\n\nElectromechanical relay SPDT and SPST contact outputs\n5A – 250 Vac; 5A – 30 Vdc (resistive load)\nFuse protected: 5A, 250V slow blow fuse\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOver Dosing Control\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSystem Error\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Signal\u003c\/td\u003e\n\u003ctd\u003e2 or 4 independent, galvanically isolated outputs\n0 – 22 mA configurable as:\n0 – 20 mA; 4 – 20 mA\n22 mA as alarm signal, configurable option\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Ouput Accuracy\u003c\/td\u003e\n\u003ctd\u003e±2% full scale\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Input Signal\u003c\/td\u003e\n\u003ctd\u003eindependent, galvanically isolated inputs (configurable for Hold \u0026amp; Cleaning functions)\nOn state: 5 to 24 Vdc, low or high level active\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDigital Output Signal\u003c\/td\u003e\n\u003ctd\u003eRS485\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBacklight\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Consumption\u003c\/td\u003e\n\u003ctd\u003e15VA\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnclosure\u003c\/td\u003e\n\u003ctd\u003e*Single case ½ DIN, type NEMA4X, IP65 ingress protection\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInstallation Category\u003c\/td\u003e\n\u003ctd\u003eII\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePanel Cutout\u003c\/td\u003e\n\u003ctd\u003e1\/2 DIN (brackets ordered seperately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003eone digital input with RS485 interface\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003eHI10X6 series – pH and Temperature (ordered seperately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eORP Electrode\u003c\/td\u003e\n\u003ctd\u003eHI20X4 series – ORP and Temperature (ordered seperately)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003eInterval log, up to 100 files, maximum 8600 records on each stored file.\nWhen the maximum limit of 100 stored files is reached, the most recent file will automatically erase the oldest one.\nEvent log, maximum 100 records. When the maximum limit i\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eRS485 serial port - Remote monitoring and control\nUSB-C port - Retrieve log files and firmware upgrading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalibration Timeout Reminder\u003c\/td\u003e\n\u003ctd\u003eyes\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnalog Output\u003c\/td\u003e\n\u003ctd\u003eup to 4 based on configuration ordered\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003eGraphic LCD, 128 x 64 pixel B\/W with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e100 – 240 Vac ±10%; 50\/60 Hz; 15VA; fuse protected (2A, 250V slow blow fuse)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e-20 to 50 ºC (-4 to 122 ºF); maximum 100% RH non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIP Rating\u003c\/td\u003e\n\u003ctd\u003eIP65\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003eWidth 144.0 mm (5.7 in.) x Height 144.0 mm (5.7 in.) x Depth 151.3 mm (6.0”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003eApproximately 1.6 kg (3.5 lb.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNotes\u003c\/td\u003e\n\u003ctd\u003e*For a water tight seal, tighten the front four screws on the front casing to 13.3 lbf·in (1.5 N·m, maximum 2.0 N·m), of torque.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI510\" target=\"_blank\" rel=\"noopener\"\u003eUniversal Process Controller - HI510\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871164924273,"sku":"HI510-0540","price":150950.25,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/510_front_1_5.jpg?v=1792645805","url":"https:\/\/hannainst.in\/products\/universal-process-controller-hi510","provider":"hanna","version":"1.0","type":"link"}