{"product_id":"water-wastewater-multiparameter-with-cod-photometer-and-ph-meter-hi83399","title":"Water \u0026 Wastewater Multiparameter (with COD) Photometer and pH meter - HI83399-02","description":"\u003cstyle\u003e\n.hanna-description {\n  line-height: 1.7;\n  color: #333;\n}\n\n.hanna-description h2 {\n  font-size: 28px;\n  margin: 35px 0 20px;\n  line-height: 1.3;\n}\n\n.hanna-description h3 {\n  font-size: 21px;\n  margin: 30px 0 12px;\n  line-height: 1.4;\n}\n\n.hanna-description p {\n  margin: 0 0 18px;\n}\n\n.hanna-description ul {\n  margin: 10px 0 25px 20px;\n  padding-left: 20px;\n}\n\n.hanna-description li {\n  margin-bottom: 8px;\n}\n\n.hanna-description .feature-title {\n  font-size: 21px;\n  font-weight: 600;\n  margin: 25px 0 8px;\n}\n\n.hanna-description .feature-group {\n  margin-bottom: 25px;\n}\n\u003c\/style\u003e\n\u003cdiv class=\"hanna-description\"\u003e\n\u003cp\u003eHI83399 benchtop photometer measures 40 different key water and wastewater quality parameters using 73 different methods that allow for multiple ranges and variations in chemistry for specific applications. The Chemical Oxygen Demand (COD) parameter is included for industrial and municipal wastewater treatment. The Phosphorous and Nitrogen parameters included are beneficial to municipal wastewater treatment customers that need to monitor their biological and chemical nutrient removal process. This photometer features an innovative optical system that uses LEDS, narrow band interference filters, focusing lens and both a silicon photodetector for absorbance measurement and a reference detector to maintain a consistent light source ensures accurate and repeatable photometric readings every time.\u003c\/p\u003e\n\u003cp\u003eA digital pH electrode input is provided allowing the user to measure pH by a traditional glass electrode. The digital pH electrode has a built in microchip within the probe that stores all of the calibration information. Having the calibration information stored in the probe allows for hot swapping of pH electrodes without having to recalibrate. All pH measurements are automatically compensated for temperature variations with a built in thermistor located in the tip of the sensing bulb for fast and accurate temperature measurement.\u003c\/p\u003e\n\u003cp\u003eTwo USB ports are provided for transferring data to a flash drive or computer and to use as a power source for the meter. For added convenience and portability the meter can also operate on an internal 3.7 VDC Lithium-polymer rechargeable battery.\u003c\/p\u003e\n\u003cp\u003eThe HI83399 offers an absorbance measuring mode that allows for CAL Check standards to be used to validate the performance of the system. The absorbance mode allows the user to select one of the 5 wavelengths of light (420 nm, 466 nm, 525 nm, 575 nm, and 610 nm) to measure and plot their own concentration versus absorbance mode. This is useful for users with their own chemical method and for education to teach the concept of absorbance by using the Beer-Lambert Law.\u003c\/p\u003e\n\u003ch2\u003eFeatures\/Benefits\u003c\/h2\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eBacklit 128 x 64 Pixel Graphic LCD Display\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eBacklit graphic display allows for easy viewing in low light conditions\u003c\/li\u003e\n\u003cli\u003eThe 128 x 64 Pixel LCD allows for a simplified user interface with virtual keys and on-screen help to guide the user through use of the meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eBuilt-in Reaction Timer for Photometric Measurements\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eThe measurement is taken after the countdown timer expires.\u003c\/li\u003e\n\u003cli\u003eCountdown timer ensures that all readings are taken at the appropriate reaction intervals regardless of user for better consistency in measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eAbsorbance mode\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eHanna’s exclusive CAL Check cuvettes for validation of light source and detector\u003c\/li\u003e\n\u003cli\u003eAllows for the user to plot concentration versus absorbance for a specific wavelength for use with user supplied chemistry or for teaching principles of photometry\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eUnits of Measure\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eAppropriate unit of measure along with chemical form is displayed along with reading\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eResult Conversion\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eAutomatically convert readings to other chemical forms with the touch of a button\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eCuvette Cover\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eAids in preventing stray light from affecting measurements\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eDigital pH Electrode Input\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eMeasure pH and temperature with a single probe\u003c\/li\u003e\n\u003cli\u003eGood Laboratory Practice (GLP) to track calibration information including date, time, buffers used, offset and slope for traceability\u003c\/li\u003e\n\u003cli\u003epH CAL Check alerts user to potential problems during the calibration process\u003c\/li\u003e\n\u003cli\u003eSpace saving having a pH meter and photometer built into one meter\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eData Logging\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eUp to 1000 photometric and pH readings can be stored by simply pressing the dedicated LOG button. Logged readings are just as easily recalled by pressing the RCL button\u003c\/li\u003e\n\u003cli\u003eSample ID and User ID information can be added to a logged reading using alphanumeric keypad\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eConnectivity\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eLogged readings can be quickly and easily transferred to a flash drive using the USB-A host port or to a computer using the micro USB-B port\u003c\/li\u003e\n\u003cli\u003eData is exported as a .CSV file for use with common spreadsheet programs\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eBattery Status Indicator\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003eIndicates the amount of battery life left\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eError Messages\u003c\/div\u003e\n\u003cul\u003e\n\u003cli\u003ePhotometric error messages include no cap, high zero, and standard too low\u003c\/li\u003e\n\u003cli\u003epH calibration messages include clean electrode, check buffer and check probe\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003ch2\u003eOn-screen Features\u003c\/h2\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eMethod Selection\u003c\/div\u003e\n\u003cdiv class=\"feature-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/method-selection_bfad8f4b-eae3-4ddb-ace5-ae978dac8bfb.png?v=1789975264\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003eUsers can easily select any one of the 60 measurement methods via the dedicated METHOD button.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eData Logging\u003c\/div\u003e\n\u003cdiv class=\"feature-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/data-logging_726a1ac1-9f9c-4eca-ba4b-009965e0af55.png?v=1789975280\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003eUp to 1000 measurement readings can be logged with user and sample ID and recalled for future use.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003epH Measurement Mode\u003c\/div\u003e\n\u003cdiv class=\"feature-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/ph-measurement-mode_c797f80d-df61-48b4-aad8-6a8f06e045b1.png?v=1789975306\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003eSelecting the pH measurement mode allows for the photometer to be used as a professional pH meter with many features including temperature compensated measurements, automatic two point calibration, and GLP.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eDigestion Parameters Features\u003c\/h2\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eCuvette Adapter\u003c\/div\u003e\n\u003cdiv class=\"feature-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI83300-Cuvette-Adapter-Closeup_de85a950-b1a2-406e-ac94-3fd21598ff1c.jpg?v=1789975334\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003eThe HI83399 is supplied with a 16 mm cuvette adapter that accepts digestion vials.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eDigestion Vial Methods\u003c\/div\u003e\n\u003cdiv class=\"feature-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/Digestion_vials_486f2288-cd97-4306-a376-90fdc080f45d.png?v=1789975353\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003eCompatible with COD (EPA, ISO, and mercury free methods), Nitrogen and Phosphorous reagetns packaged in 16 mm digestion vial. Reagents are sold separately.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"feature-group\"\u003e\n\u003cdiv class=\"feature-title\"\u003eCOD Reactor for Digestion Vials\u003c\/div\u003e\n\u003cdiv class=\"feature-title\"\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/HI839800_COD_Reactor_3e78bcae-cd58-4677-9965-f3e5291d79da.png?v=1789975373\" alt=\"\"\u003e\u003c\/div\u003e\n\u003cp\u003eA COD reactor is used to heat the digestion vials. The digestion vials must be heated to a specific temperature for a period time making the HI839800 an important accessory required to have a complete wastewater treatment monitoring system.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch2\u003eAdvanced Optical System\u003c\/h2\u003e\n\u003cp\u003eHI83300 is designed with an innovative optical system that incorporates a beam splitter so that light can be used for absorbance readings and for a reference detector. The reference detector monitors the intensity of light and modulates when there is drift due to power fluctuation or the heating of the optical components. Each part has an important role in providing unparalleled performance from a photometer.\u003c\/p\u003e\n\u003cp\u003e\u003cimg src=\"https:\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/OpticalSystem_599d0573-37dc-446b-b018-c5842649c240.jpg?v=1789975403\" alt=\"\"\u003e\u003c\/p\u003e\n\u003cdiv class=\"feature-title\"\u003eHigh Efficiency LED Light Source\u003c\/div\u003e\n\u003cp\u003eAn LED light source offers superior performance as compared to a tungsten lamp. LEDs have a much higher luminous efficiency, providing more light while using less power. They also produce very little heat, which could otherwise affect the optical components an electronic stability. LEDs are available in a wide array of wavelengths, whereas tungsten lamps are supposed to be white light (all wavelengths of visible light) but actually have a poor blue\/violet light output.\u003c\/p\u003e\n\u003cdiv class=\"feature-title\"\u003eHigh Quality Narrow Band Interference Filters\u003c\/div\u003e\n\u003cp\u003eThe narrow band interference filter not only ensure greater wavelength accuracy (± 1 nm) but are extremely efficient. The filters used allow up to 95% of the light from the LED to be transmitted as compared to other filters that are only 75% efficient. The higher efficiency allows for a brighter, stronger light source. The end result is higher measurement stability and less wavelength error.\u003c\/p\u003e\n\u003cdiv class=\"feature-title\"\u003eReference Detector for a Stable Light Source\u003c\/div\u003e\n\u003cp\u003eA beam splitter is used as part of the internal reference system of the HI83300 photometer. The reference detector compensates for any drift due to power fluctuations or ambient temperature changes. Now you can rely on a stable source of light between your blank (zero) measurement and sample measurement.\u003c\/p\u003e\n\u003cdiv class=\"feature-title\"\u003eLarge Cuvette Size\u003c\/div\u003e\n\u003cp\u003eThe sample cell of the HI83300 fits a round, glass cuvette with a 25 mm path length. Along with the advanced optical components, the larger size of the cuvette greatly reduces errors in rotation from the indexing mark of the cuvettes. The relatively long path length of the sample cuvette allows the light to pass through more of the sample solution, ensuring accurate measurements even in low absorbance samples.\u003c\/p\u003e\n\u003cdiv class=\"feature-title\"\u003eFocusing Lens for Greater Light Yield\u003c\/div\u003e\n\u003cp\u003eAdding a focusing lens to the optical path allows for the collection of all of the light that exits the cuvette and focusing the light on the silicon photo detector. This novel approach to photometric measurements cancels the errors from imperfections and scratches present in the glass cuvette eliminating the need to index the cuvette.\u003c\/p\u003e\n\u003c\/div\u003e\n\u003ch3\u003eSpecifications\u003c\/h3\u003e\n\u003ctable\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003ctd\u003eSKU\u003c\/td\u003e\n\u003ctd\u003eHI83399-02\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eName\u003c\/td\u003e\n\u003ctd\u003eWater \u0026amp; Wastewater Multiparameter (with COD) Photometer and pH meter - HI83399\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Range\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 6.5 to 8.5 pH pH electrode: -2.00 to 16.00 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Resolution\u003c\/td\u003e\n\u003ctd\u003ePhotometer: 0.1 pH pH electrode: 0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Accuracy\u003c\/td\u003e\n\u003ctd\u003ePhotometer: ±0.1 pH pH electrode: ±0.01 pH\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Calibration\u003c\/td\u003e\n\u003ctd\u003eAutomatic one or two point calibration with one set of standard buffers available (4.01, 6.86, 7.01, 9.18, 10.01)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Temperature Compensation\u003c\/td\u003e\n\u003ctd\u003eAutomatic (-5.0 to 100.0 ℃; 23.0 to 212.0 °F); limits reduced based on the pH electrode used\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH CAL Check (electrode diagnostics)\u003c\/td\u003e\n\u003ctd\u003eclean electrode and check buffer\/check probe displayed during calibration\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Method\u003c\/td\u003e\n\u003ctd\u003ePhotometer: phenol red\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Range\u003c\/td\u003e\n\u003ctd\u003e±1000 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH-mV Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.2 mV\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 10.0 mg\/L (as O\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.4 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDissolved Oxygen Measurement Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Azide modified Winkler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 4.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAbsorbance Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.003Abs @ 1.000 Abs\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e) Seawater: 0 to 300 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAlkalinity Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.00 mg\/L (as Al\u003csup\u003e3+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAluminum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the aluminon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 3.00 mg\/L Low Range (16 mm vial): 0.00 to 3.00 mg\/L Medium Range: 0.00 to 10.00 mg\/L High Range: 0.0 to 100.0 mg\/L High Range (16 mm vial): 0.0 to 100.0 mg\/L (all as NH\u003csub\u003e3\u003c\/sub\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Resolution\u003c\/td\u003e\n\u003ctd\u003eLow and Medium Range: 0.01 mg\/L High Range: 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.04 mg\/L ±4% of reading Low Range (16 mm vial): ±0.10 mg\/L or ±5% of reading Medium Range: ±0.05 mg\/L ±5% of reading High range: ±0.5 mg\/L ±5% of reading High range (16 mm vial): ±1 mg\/L or ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAmmonia Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1426-92, Nessler method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.50 mg\/L (as SDBS)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.04 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eAnionic Surfactants Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA method 425.1 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 5540C, Anionic Surfactants as MBAS\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 8.00 mg\/L (as Br\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.08 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBromine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0 to 400 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e) Seawater: 200 to 600 mg\/L (as Ca\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater: ±10 mg\/L ±5% of reading Seawater: ±6% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCalcium Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater: Adaptation of the Oxalate method Seawater: Adaptation of the Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 150 mg\/L Medium Range: 0 to 1500 mg\/L High Range:0 to 15000 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±5 mg\/L ±4% of reading Medium Range: ±15 mg\/L ±4% of reading High Range: ±150 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChemical Oxygen Demand Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the USEPA 410.4 ISO dichromate methods Mercury-free dichromate green method (LR \u0026amp; MR); dichromate method (HR)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L (as Cl⁻)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChloride Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±6% of reading at 25 °C\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as ClO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.10 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Dioxide Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Chlorophenol Red method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e) Ultra Low Range: 0.000 to 0.500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L Ultra Low Range: 0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFree Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading Ultra Low Range: ±0.020 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 5.00 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e) Ultra Low Range: 0.000 to 0.500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e) Ultra High Range: 0 to 500 mg\/L (as Cl\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L Ultra Low Range: 0.001 mg\/L Ultra High Range:1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eTotal Chlorine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading Ultra Low Range: ±0.020 mg\/L ±3% of reading Ultra High Range: ±3 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChlorine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA 330.5 DPD method Free Chlorine (ULR) \u0026amp; Total Chlorine (UHR): Adaptation of the Standard Methods for Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-Cl\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Cr\u003csup\u003e6+\u003c\/sup\u003e) High Range: 0 to 1000 µg\/L (as Cr\u003csup\u003e6+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±1 µg\/L ±4% of reading High Range: ±5 µg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eChromium, Hexavalent Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, D1687-92, Diphenylcarbohydrazide method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Range\u003c\/td\u003e\n\u003ctd\u003e0 to 500 PCU (Platinum Cobalt Units)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Resolution\u003c\/td\u003e\n\u003ctd\u003e1 PCU\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Accuracy\u003c\/td\u003e\n\u003ctd\u003e±10 PCU ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eColor, Water Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Colorimetric Platinum Cobalt method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.500 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e) High range: 0.00 to 5.00 mg\/L (as Cu\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±5% of reading High Range ±0.02 mg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCopper Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA bicinchoninate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Range\u003c\/td\u003e\n\u003ctd\u003e0 to 80 mg\/L (as CYA)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 mg\/L ±15% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCyanuric Acid Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the turbidimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as F\u003csup\u003e-\u003c\/sup\u003e) High range: 0.0 to 20.0 mg\/L (as F\u003csup\u003e-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading High Range: ±0.5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eFluoride Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, SPADNS method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 250 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e) Medium Range: 200 to 500 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e) High Range: 400 to 750 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±5 mg\/L ±4% of reading Medium Range: ±7 mg\/L ±3% of reading High Range: ±10 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Total Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA recommended method 130.1\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.70 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Calcium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as CaCO\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.11 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHardness, Magnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, EDTA Colorimetric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Range\u003c\/td\u003e\n\u003ctd\u003e0 to 400 µg\/L (as N\u003csub\u003e2\u003c\/sub\u003eH\u003csub\u003e4\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±4% of full scale reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eHydrazine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the ASTM Manual of Water and Environmental Technology, method D1385-88, p-Dimethylaminobenzaldehyde method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 12.5 mg\/L (as I\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIodine Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, DPD method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.600 mg\/L (as Fe) High Range: 0.00 to 5.00 mg\/L (as Fe)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.01 mg\/L ±8% of reading High Range: ±0.04 mg\/L ±2% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eIron Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the TPTZ Method High Range: Adaptation of Standard Methods for the Examination of Water and Wastewater, 3500-Fe B., Phenanthroline Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as Mg\u003csup\u003e2+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMagnesium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Calmagite method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0 to 300 µg\/L (as Mn) High Range: 0.0 to 20.0 (as Mn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±10 µg\/L ±3% of reading High Range: ±0.2 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eManganese Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN Method High Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Periodate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 40.0 mg\/L (as Mo\u003csup\u003e6+\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.3 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eMolybdenum Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the mercaptoacetic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eYou know what the French Say\u003c\/td\u003e\n\u003ctd\u003eBodhidharma\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.000 to 1.000 mg\/L (as Ni) High Range: 0.00 to 7.00 g\/L (as Ni)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L; 0.01 g\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow range: ±0.010 mg\/L ±7% of reading High Range: ±0.07 g\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNickel Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the PAN method High Range: Adaptation of the photometric method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 30.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e- N) 16 mm vial: 0.0 to 30.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e- N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.5 mg\/L ±10% of reading 16 mm vial: ±1.0 mg\/L or ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrate Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the cadmium reduction method 16 mm vial: Chromotropic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: 0 to 600 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N) High Range: 0 to 150 mg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e) Seawater Ultra Low Range: 0 to 200 µg\/L (as NO\u003csub\u003e2\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 1 µg\/L; 1 mg\/L Seawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: ±20 µg\/L ±4% of reading High Range: ±4 mg\/L ±4% of reading Seawater ±10 µg\/L ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrite Method\u003c\/td\u003e\n\u003ctd\u003eLow Range and Seawater: Adaptation of the EPA Diazotization method 354.1 High Range: Adaptation of the Ferrous Sulfate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.0 to 25.0 mg\/L (as NO\u003csub\u003e3\u003c\/sub\u003e\u003csup\u003e-\u003c\/sup\u003e-N) High Range: 0 to 150 mg\/L (as N)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L; 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±1.0 mg\/L or ±5% of reading High Range: ±3 mg\/L or ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNitrogen, Total Method\u003c\/td\u003e\n\u003ctd\u003eChromotropic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Range\u003c\/td\u003e\n\u003ctd\u003e0 to 1000 µg\/L (as DEHA) 0.00 to 1.50 mg\/L (as Carbohydrazide) 0.00 to 2.50 mg\/L (as Hydroquinone) 0.00 to 4.50 mg\/L (as ISO-ascorbic acid)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Resolution\u003c\/td\u003e\n\u003ctd\u003e1 µg\/L (DEHA); 0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 µg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOxygen, Scavenger Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the iron reduction method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 2.00 mg\/L (as O\u003csub\u003e3\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.02 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eOzone Method\u003c\/td\u003e\n\u003ctd\u003eColorimetric DPD Method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Range\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: 0.00 to 2.50 mg\/L (as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e) High range: 0.0 to 30.0 mg\/L(as PO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e3-\u003c\/sup\u003e) Seawater Ultra Low Range: 0 to 200 µg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Resolution\u003c\/td\u003e\n\u003ctd\u003eFreshwater: 0.01 mg\/L; 0.1 mg\/L Seawater: 1 µg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Accuracy\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: ±0.04 mg\/L ±4% of reading High Range: ±1 mg\/L ±4% of reading Seawater Ultra Low Range: ±5 µg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphate Method\u003c\/td\u003e\n\u003ctd\u003eFreshwater Low Range: Adaptation of the Ascorbic Acid method Freshwater High Range and Seawater Ultra Low Range: Adaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Amino Acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 1.60 mg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.05 mg\/L or ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Acid Hydrolyzable Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the EPA method 365.2 and Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-P E, ascorbic acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 1.60 mg\/L (as P) High Range: 0.0 to 32.6 mg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.05 mg\/L or ±4% of reading High Range: ±0.5 mg\/L or ±4% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Reactive Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, ascorbic acid method, and EPA method 365.2 High Range: Adaptation of the vanadomolybdophosphoric acid method.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 1.15 mg\/L (as P) High Range: 0.0 to 32.6 mg\/L (as P)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.05 mg\/L or ±6% of reading High Range: ±0.5 mg\/L or ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Resolution\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.01 mg\/L; 0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhosphorous, Total Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of Standard Methods for the Examination of Water and Wastewater, 20\u003csup\u003eth\u003c\/sup\u003e edition, 4500-P E, ascorbic acid method, and EPA method 365.2 High Range: Adaptation of the vanadomolybdophosphoric acid method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Range\u003c\/td\u003e\n\u003ctd\u003e0.0 to 20.0 mg\/L (as K)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Resolution\u003c\/td\u003e\n\u003ctd\u003e0.1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Accuracy\u003c\/td\u003e\n\u003ctd\u003e±3.0 mg\/L ±7% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePotassium Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Turbidimetric Tetraphenylborate method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Range\u003c\/td\u003e\n\u003ctd\u003eLow Range: 0.00 to 2.00 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e) High Range: 0 to 200 mg\/L (as SiO\u003csub\u003e2\u003c\/sub\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L; 1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Accuracy\u003c\/td\u003e\n\u003ctd\u003eLow Range: ±0.03 mg\/L ±3% of reading High Range: ±1 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilica Method\u003c\/td\u003e\n\u003ctd\u003eLow Range: Adaptation of the ASTM Manual of Water and Environmental Technology, D859, Heteropoly Molybdenum Blue method High Range: Adaptation of the USEPA Method 370.1 and Standard Method 4500-SiO\u003csub\u003e2\u003c\/sub\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Range\u003c\/td\u003e\n\u003ctd\u003e0.000 to 1.000 mg\/L (as Ag)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Resolution\u003c\/td\u003e\n\u003ctd\u003e0.001 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.020 mg\/L ±5% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSilver Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the PAN method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Range\u003c\/td\u003e\n\u003ctd\u003e0 to 150 mg\/L (as SO\u003csub\u003e4\u003c\/sub\u003e\u003csup\u003e2-\u003c\/sup\u003e)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Resolution\u003c\/td\u003e\n\u003ctd\u003e1 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Accuracy\u003c\/td\u003e\n\u003ctd\u003e±5 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eSulfate Method\u003c\/td\u003e\n\u003ctd\u003eTurbidimetric - Sulfate is precipitated with barium chloride crystals\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Range\u003c\/td\u003e\n\u003ctd\u003e0.00 to 3.00 mg\/L (as Zn)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Resolution\u003c\/td\u003e\n\u003ctd\u003e0.01 mg\/L\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Accuracy\u003c\/td\u003e\n\u003ctd\u003e±0.03 mg\/L ±3% of reading\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eZinc Method\u003c\/td\u003e\n\u003ctd\u003eAdaptation of the Standard Methods for the Examination of Water and Wastewater, 18\u003csup\u003eth\u003c\/sup\u003e edition, Zincon method\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eInput Channels\u003c\/td\u003e\n\u003ctd\u003e1 pH electrode input and 5 photometer wavelengths\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003epH Electrode\u003c\/td\u003e\n\u003ctd\u003edigital pH electrode (not included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Source\u003c\/td\u003e\n\u003ctd\u003e5 LEDs with 420 nm, 466 nm, 525 nm, 575 nm, and 610 nm narrow band interference filters\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePhotometer\/Colorimeter Light Detector\u003c\/td\u003e\n\u003ctd\u003esilicon photodetector\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Bandwidth\u003c\/td\u003e\n\u003ctd\u003e8 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBandpass Filter Wavelength Accuracy\u003c\/td\u003e\n\u003ctd\u003e±1 nm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eCuvette Type\u003c\/td\u003e\n\u003ctd\u003eround, 24.6 mm\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eNumber of Methods\u003c\/td\u003e\n\u003ctd\u003e128 max.\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eGLP\u003c\/td\u003e\n\u003ctd\u003ecalibration data for connected pH electrode\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDisplay\u003c\/td\u003e\n\u003ctd\u003e128 x 64 pixel LCD with backlight\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Type\u003c\/td\u003e\n\u003ctd\u003elog on demand with user name and sample ID optional input\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eLogging Memory\u003c\/td\u003e\n\u003ctd\u003e1000 readings\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eConnectivity\u003c\/td\u003e\n\u003ctd\u003eUSB-A host for flash drive; micro-USB-B for power and computer connectivity\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePower Supply\u003c\/td\u003e\n\u003ctd\u003e5 VDC USB 2.0 power adapter with USB-A to micro-USB-B cable (included)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eBattery Type\/Life\u003c\/td\u003e\n\u003ctd\u003e3.7 VDC Li-polymer rechargeable battery \/ \u0026gt;500 photometric measurements or 50 hours of continuous pH measurement\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eEnvironment\u003c\/td\u003e\n\u003ctd\u003e0 to 50.0 ℃ (32 to 122.0 °F); 0 to 95% RH, non-condensing\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eWeight\u003c\/td\u003e\n\u003ctd\u003e1.0 kg (2.2 lbs.)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003eDimensions\u003c\/td\u003e\n\u003ctd\u003e206 x 177 x 97 mm (8.1 x 7.0 x 3.8”)\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003ch3\u003eOrdering Info\u003c\/h3\u003e\n\u003cp\u003eHI83399-02 is supplied with sample cuvettes and caps (4 ea.), cloth for wiping cuvettes, USB to micro USB cable connector, power adapter and instruction manual.\u003c\/p\u003e\n\u003ch3\u003eManuals\u003c\/h3\u003e\n\u003cp\u003e\u003ca href=\"https:\/\/manuals.hannainst.com\/HI83399\" rel=\"noopener\" target=\"_blank\"\u003e\u003cspan style=\"text-decoration: underline;\"\u003eWastewater Multiparameter Photometer and pH Meter\u003c\/span\u003e\u003c\/a\u003e\u003c\/p\u003e","brand":"Hanna Instruments","offers":[{"title":"Default Title","offer_id":67871461998961,"sku":"HI83399-02","price":204471.0,"currency_code":"INR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/1086\/9535\/5761\/files\/hi83399-upper-angle-cover-closed_2_7201c991-0f0d-4f00-8f0a-b82a235af032.jpg?v=1792646987","url":"https:\/\/hannainst.in\/products\/water-wastewater-multiparameter-with-cod-photometer-and-ph-meter-hi83399","provider":"hanna","version":"1.0","type":"link"}