| SKU |
HI6321 |
| Name |
Advanced Conductivity Benchtop Meter - HI6321 |
| Conductivity Range |
0.000 to 9.999 µS/cm; 10.00 to 99.99 µS/cm; 100.0 to 999.9 µS/cm; 1.000 to 9.999 mS/cm; 10.00 to 99.99 mS/cm; 100.0 to 1000.0 mS/cm |
| Conductivity Resolution |
0.001 µS/cm; 0.01 µS/cm; 0.1 µS/cm; 0.001 mS/cm; 0.01 mS/cm; 0.1 mS/cm |
| Conductivity Accuracy |
±1 % of reading (±0.01 µS/cm) |
| Resistivity Range |
1.0 to 99.9 Ω·cm; 100 to 999 Ω·cm; 1.00 to 9.99 KΩ·cm; 10.0 to 99.9 KΩ·cm; 100 to 999 KΩ·cm; 1.00 to 9.99 MΩ·cm; 10.0 to 100.0 MΩ·cm |
| Resistivity Resolution |
0.1 Ω·cm; 1 Ω·cm; 0.01 KΩ·cm; 0.1 KΩ·cm; 1 KΩ·cm; 0.01 MΩ·cm; 0.1 MΩ·cm |
| Resistivity Accuracy |
±1 % of reading (±1 Ω·cm) |
| Total Dissolved Solids (TDS) Range |
0.000 to 9.999 ppm; 10.00 to 99.99 ppm; 100.0 to 999.9 ppm; 1.000 to 9.999 ppt; 10.00 to 99.99 ppt; 100.0 to 400.0 ppt; actual TDS (with 1.00 factor) |
| Total Dissolved Solids (TDS) Resolution |
0.001 ppm; 0.01 ppm; 0.1 ppm; 0.001 ppt; 0.01 ppt; 0.1 ppt |
| Total Dissolved Solids (TDS) Accuracy |
±1 % of reading (±0.01 ppm) |
| Salinity Range |
0.00 to 42.00 PSU - Practical Scale 0.00 to 80.00 ppt - Natural Sea Water 0.0 to 400.0 % - Percent Scale |
| Salinity Resolution |
0.01 for Practical Scale / Natural Sea Water 0.1 % for Percent Scale |
| Salinity Accuracy |
±1 % of reading |
| Temperature Range |
−20.0 to 120.0 °C −4.0 to 248.0 °F 253.0 to 393.0 K |
| Temperature Resolution |
0.1 °C; 0.1 °F; 0.1 K |
| Temperature Accuracy |
±0.2 °C; ±0.4 °F; ±0.2 K |
| Conductivity Calibration points |
Auto standard recognition / User standard, Single Point / Multi Point calibration |
| Conductivity Calibration Standard solutions |
84.00 µS/cm, 1.413 mS/cm, 5.000 mS/cm, 12.88 mS/cm, 80.00 mS/cm, 111.8 mS/cm |
| Conductivity Calibration Reminder |
Disabled Daily: 0 m in. to 23 hours and 59 m in. Periodic: 1 m in. to 500 days, 23 hours and 59 m in. |
| Salinity Calibration |
1 point for Percent Scale |
| Temperature Compensation |
Automatic or Manual |
| Reading Modes |
Direct Direct/Autohold |
| Reading Stability criteria |
Accurate Medium Fast |
| Reading Sampling |
rate 1000 ms |
| EC Views Basic |
Measurement (EC, Resistivity, TDS, Salinity, Temperature) Stability status |
| EC Views Simple GLP |
Basic view information Last calibration date, offset |
| EC Views Full GLP |
Simple GLP information and calibration point details |
| EC Views Table |
Measurements updated every second are displayed in table |
| EC Views Graph (Plot) |
Measurement versus time graph can be panned or zoomed (pinch-to-zoom technology) |
| Logging Type |
Automatic, Manual, Autohold |
| Logging Number of records |
50 000 maximum per file Stores at least 1 000 000 data points per user |
| Logging Automatic interval |
1, 2, 5, 10, 30 seconds 1, 2, 5, 10, 15, 30, 60, 120, 150, 180 minutes |
| Logging Sample ID |
Incremental mode |
| Logging Export option |
.csv file format |
| Users |
Up to 9 users and the default administrator account |
| Connectivity USB-A |
2 ports for keyboard input or USB thumb drive |
| Connectivity USB-C |
1 port for PC connectivity and USB-C type thumb drive |
| Connectivity Wi-Fi & Ethernet |
FTP Web server Log transfer and download Email |
| Connectivity RS232 |
Connecting peripherals |
| Power supply |
DC adapter 100-240AC to 24VDC 2.5A |
| Environment |
0 - 50 °C / 32 - 122 °F / 273 - 323 K maximum 95% RH non-condensing |
| Dimensions |
205 x 160 x 77 mm (8.0 x 6.2 x 3.0 “) |
| Weight |
Approximately 1.2 kg (26.5 lbs.) |