Hanna Instruments Worldwide
The Hanna Advantage: A Worldwide Leader in Technology and Innovation 100% Quality  360 Value
Contact Hanna: +1 (800) 426-6287

pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711

Ships within 24 hours (business days)

61,275

GST and Shipping charges are extra

HI8711 allows the selection of two set points with two independent outputs for acid and alkaline dosages.

  • Auto-diagnostics to verify offset, slope calibration, and electrode contamination/deterioration
  • Hanna’s exclusive Fail Safe Alarm System protects against risks typical of industrial environments
  • Selectable manual ON, OFF and automatic dosing control for alkaline and acid dosing with indicator
  • 0.2 to 3.00 pH alarm tolerance range

Ships within 24 hours (business days)

QTY:

  Add to wish list

Fail Safe Alarm System

Hanna’s exclusive Fail Safe Alarm System protects against problems caused by power supply failure or signal interruption, which are typical risks in industrial environments. An alarm condition is indicated by a red LED, located directly on the front panel of the controller.

Overtime Dosing Protection

The HI8711 incorporates adjustable overtime dosing protection from 5 to 60 minutes. If dosing exceeds selected time, the alarm will be triggered and the dosing contact will deactivate. This feature can be activated or deactivated.

Output and Input Connections

Each model accepts either a direct input from a pH or ORP electrode or from a transmitter through 4-20 mA input. The instrument also provides ±5V power output and input terminals for amplified electrodes. Moreover, you can choose the output configuration for connecting a recorder or a PLC, between 0-20 or 4-20 mA.

Self-Diagnostic Test

Built-in autodiagnostic functions enable the user to check and troubleshoot any malfunctions. The functions are made via front panel keys to isolate the cause of malfunction whether it is due to pH electrode contamination, internal offset circuit or the amplifier circuit.

Matching Pin Connection

Supports potential matching pin connection to avoid typical problems caused by grounding loop currents, such as progressive damage of the electrode, fluctuating measurements, and poor process regulation.

Robust Design

A removable, transparent splash-proof cover protects the front panel.

SKU HI8711
Name pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711
pH Range 0.00 to 14.00 pH
pH Resolution 0.01 pH
pH Accuracy ±0.02 pH (0 to 100 °C)/ ±0.05 pH (-20 to 0 °C) (electrode); ±0.5% (transmitter)
pH Dosing Relay 2, isolated, 2 A, Max 240 V, resistive load, 1000000 strokes (not fuse protected)
pH Dosing Set Point 0.00 to 14.00 pH
Dosing Control OFF/AUTO/ON with selection switch
Over Dosing Control Adjustable, from 5 min to 60 min with knob or Disable by wire strap – on rear panel
Analog Input Signal 4 to 20 mA
Analog Ouput Signal 0-20 mA or 4-20 mA (isolated)
Backlight Continuous ON
Voltage Output ±5 Vcc; 150 mA max load for amplified electrodes
Enclosure Black anodized aluminium body; front and back with ABS; transparent splash-proof front cover
Power Supply 115 or 230 Vac; 60/50 Hz
Environment -10 to 50°C (14 to 122°F); RH max 95% non-condensing
Dimensions 141 x 69 mm (5.6 x 2.7”)
Weight 1 kg (2.2 lb.)

pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711

Reviews

There are no reviews yet.

Be the first to review “pH Analog Controller with Dual Output and Self-Diagnostic Test – HI8711”

Your email address will not be published. Required fields are marked *